Multichannel Compressor
Owner’s Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Solid State Logic
S U P E R A N A L O G U E
M U L T I C H A N N E L
C O M P R E S S O R
Super-Analogue™ Outboard
Owner’s Manual
82S6XL010D
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
Solid State Logic
Begbroke, Oxford, England, OX5 1RU • +44 (0)1865 842300
320 West 46th Street, 2nd Floor, New York, NY 10036, USA • +1 (1) 212 315 1111
Suite 401, 5757 Wilshire Blvd, Los Angeles, CA 90036, USA • +1 (1) 323 549 9090
3-55-14 Sendagaya, Shibuya-Ku, Tokyo 151-0051, Japan • +81 (0)3 5474 1144
7 bis, rue de la Victoire, le Blanc Mesnil, Paris 93150, France • +33 (0)1 48 67 84 85
Via Timavo 34, 20124 Milano, Italy • +39 (0)39 2328 094
© Solid State Logic
All Rights reserved under International and Pan-American Copyright Conventions
Solid State Logic, SSL and XLogic are trademarks of Solid State Logic
All other product names and trademarks are the property of their respective owners
No part of this publication may be reproduced in any form or
by any means, whether mechanical or electronic, without the
written permission of Solid State Logic, Oxford, England
Revision 0A, September 2003
Revision 0B, January 2004
Revision 0C, June 2004
Revision 0D, July 2004
Minor changes, November 2004
Minor changes, June 2005
As research and development is a continual process, Solid State Logic reserves the right
to change the features and specifications described herein without notice or obligation
E&OE
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
1.0 Introduction
3
2.0 Safety Considerations
Safety Warnings
4
4
3.0 Installation
6
6
6
6
Setting the mains voltage selector
Mounting
Connections
4.0 Operation
7
7
7
8
8
Compressor Controls
Side Chain Adjust Section
Mode Section
Fader Section
Appendices:
A
B
Internal Links and Fuses
Connector Details
9
9
C
D
E
Electronic Specification
Calibration Instructions
Physical Specification
Environmental Specification
10
11
13
13
F
Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
c
oig
XL
Page 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
1.0 Introduction
The XLogic Multichannel Compressor is a 2U rack-mounting six-channel compressor. It utilises classic SSL
Centre Section compressor design elements within a SuperAnalogue design topology. This brings the dual
benefits of spectacular surround audio performance with a universally acclaimed compressor characteristic.
The unit contains two separate compressors. Normally the upper one controls the left, centre, right and surround
channels and the lower one the LFE channel, but the DUAL STEREO switch reassigns the controls so that the
lower set control the surround channels and the upper set control left, centre, right and LFE channels.
The SIDE CHAIN TRIM controls allow different thresholds to be set for left/right, centre, surround and LFE
channels. The centre and surround ISO switches bypass the respective compressor channels completely.
A six channel Master Fader and Autofade control provide overall level control of the mix
The object of this manual is to provide purchasers of the XLogic Multichannel Compressor unit with information
in the following areas:
• Operation of the unit
• Safety considerations
• Installation requirement
• Electrical connections and cabling
• Connector pin-outs
• Specifications and physical dimensions
Warranty
The warranty period for this unit is 12 months from date of purchase.
In Warranty Repairs
In the event of a fault during the warranty period the unit must be returned to your local distributor who will
arrange for it to be shipped to Solid State Logic for repair. All units should be shipped to Solid State Logic in their
original packaging. Solid State Logic can not be held responsible for any damage caused by shipping units in
other packaging. In such cases Solid State Logic will return the unit in a suitable box, which you will be charged
for. Please do not send manuals, power leads or any other cables - Solid State Logic can not guarantee to return
them to you. Please also note that warranty returns will only be accepted as such if accompanied by a copy of the
receipt or other proof of purchase.
Out of Warranty Repairs
In the event of a fault after the warranty period has expired, return the unit in its original packaging to your local
distributor for shipment to Solid State Logic. You will be charged for the time spent on the repair (at Solid State
Logic's current repair rate) plus the cost of parts and shipping.
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
2.0 Safety considerations
This section contains definitions and warnings, and practical information to ensure a safe working environment.
Please take time to read this section before undertaking any installation work.
2.1 Definitions
‘Maintenance’
All maintenance must be carried out by fully trained personnel. Note: it is advisable to observe suitable ESD
precautions when maintenance to any part is undertaken.
‘Non-User Adjustments’
Adjustments or alterations to the equipment may affect the performance such that safety and/or international
compliance standards may no longer be met. Any such adjustments must therefore only be carried out by fully
trained personnel.
‘Users’
This equipment is designed for use solely by engineers and competent operators skilled in the use of professional
audio equipment.
‘Environment’
This product is a Class A product intended to form an integrated component part of a professional audio
recording, mixing, dubbing, film, TV, radio broadcast or similar studio wherein it will perform to specification
providing that it is installed according to professional practice.
2.2 Electrical Safety Warning
When installing or servicing any item of Solid State Logic equipment with power applied, when cover
panels are removed, HAZARDOUS CONDITIONS CAN EXIST.
These hazards include:
High voltages
High energy stored in capacitors
High currents available from DC power busses
Hot component surfaces
Any metal jewellery (watches, bracelets, neck-chains and rings) that could inadvertently come into contact
with uninsulated parts should always be removed before reaching inside powered equipment.
2.3 Installation
Voltage Selection and Fusing
All XLogic units have selectable voltage inlets. Always confirm that the input mains voltage range is set correctly
before applying power. Always isolate the mains supply before changing the input range setting.
If it is ever necessary to replace a blown mains fuse, then always use the correct rating and type of replacement.
If a correctly rated fuse continues to blow, then a fault exists and the cause should be investigated or the unit
returned to Solid State Logic for repair/replacement as appropriate.
Details of mains settings and correct fuse ratings can be found in Section 3.1 and Appendix A of this manual.
Safety Earth Connection
Any mains powered item of Solid State Logic equipment that is supplied with a 3-core mains lead (whether
connectorised or not) should always have the earth wire connected to the mains supply ground. This is the safety
earth and grounds the exposed metal parts of the racks and cases and should not be removed for any reason.
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Considerations
Mains Supply and Phases
Solid State Logic equipment is designed for connection to single phase supplies with the Neutral conductor at
earth potential – category TN – and is fitted with a protective fuse in the Live conductor only. It is not designed
for use with Phase (Live) and Neutral connections reversed or where the Neutral conductor is not at earth
potential (TT or IT supplies).
Mains cables will be coded with the following colour scheme:
LIVE:
Brown
NEUTRAL:
EARTH:
Blue
Yellow/Green
Mains Isolation and Over-Current Protection
An external disconnect device is required for this equipment which must be installed according to current wiring
regulations. A detachable power cord, as fitted to this equipment, is a suitable disconnect device.
An external over-current protection device is required to protect the wiring to this equipment which must be
installed according to the current wiring regulations. The fusing or breaking-current are defined in the product
specification. In certain countries this function is supplied by use of a fused plug.
CE Certification
Note that the majority of cables supplied with SSL equipment are fitted with ferrite rings at each end. This is to
comply with current European CE regulations and these ferrites should not be removed.
If any of the unit metalwork is modified in any way this may the adversely affect the CE certification status of
the product.
FCC Certification
The XLogic unit has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
3.0 Installation
3.1 Voltage Selection
Before connecting the mains supply ensure that the
voltage range selector next to the IEC socket on the rear of
the unit is correctly set. The input setting must be
confirmed before applying power. The input module can
be configured to be one of 4 voltage settings. The setting
is indicated by a plastic pin protruding through the
appropriate hole in the fuse panel - the example shown here is set for 240V operation.
100V
120V
230V
240V
The setting is altered by a small vertical PCB which can be fitted in 4 positions. To change the setting:
• Switch off and remove the IEC lead.
• Using a small flat-bladed screwdriver, lever open the fuse panel to the right of the connector.
• At the right hand side is a vertical PCB with a plastic key which indicates the setting. Using pliers, pull
out the PCB.
2 4 0
• The PCB has to be rotated until the
desired voltage is shown along the
edge which plugs into the module.
The plastic key (and this bit is quite
fiddly) must also be rotated so that it
points out of the module so that the
round pin aligns with the appropriate
hole in the cover panel; (refer to the
adjacent illustrations).
1 2 0
2 3 0
1 0 0
100
120
230
240
100V Setting
(use for 90-105V) (use for 105-125V)
120V Setting
230V Setting
(do not use)
240V Setting
(use for 220-240V)
Note. Where the mains voltage is a nominal 230V, the ‘240V Setting’ should be used – not the ‘230V Setting’!
• Re-insert the PCB and replace the fuse panel. The plastic pin should project through the appropriate
hole.
3.2 Mounting
The XLogic unit is designed to be rack mounted. It is 2 RU (89mm/3.5 inches) high. Its depth is:
325 mm/12.8 inches not including heatsink
365 mm/14.3 inches including heatsink
400 mm/15.75 inches including connectors
The unit must be mounted on suitable rack shelves: do not rely on the rack mounting ears alone.
A 1RU space should be left above each unit to ensure adequate ventilation.
3.3 Connection
The unit has six input XLRs (female) and six output XLRs (male). Connect the inputs to the main output
insert sends of your console or to your workstation outputs. Connect the outputs to the corresponding
insert returns or to your workstation inputs.
When the unit is switched off the input XLRs are linked to the output XLRs by relays, so the unit will pass
signal even when switched off. There is a 3 second delay after switching on before the bypass relays are
energised to allow the power rails to settle, thus avoiding unpleasant thumps and pops on your
monitoring.
Note that when switched off the DC coupled input stage of the XLogic Multichannel Compressor can load
the output stages of some devices, causing low level distortion. For this reason it is not advisable to leave
the unit connected and switched off.
Once the unit is connected switch it on, then route signal to each channel in turn and check that the correct
signal LED lights yellow in the MAX display and that the signal is returned to the correct input on your
console or workstation.
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation
4.0 Operation
The XLogic Multichannel Compressor unit is a 2U rack-mounting six-channel compressor designed to provide
extremely flexible control over a 5.1 channel mix, or to be used as two separate compressors when working on
stereo material. The compressor design is very similar to that found in the XL 9000 console centre section, but
with additional controls to provide the flexibility that modern 5.1 productions require. The signal path is
balanced and DC coupled through out: this ensures extended bandwidth, low noise and low distortion.
5.1 mixing presents a number of challenges to the engineer that are not present when working in stereo. This is
essentially because the signal content can vary hugely between speakers - both in level and frequency content –
unlike stereo material where the two channels are normally similar in both level and content. This presents a
number of potential problems including:
• The LFE channel will almost certainly require different attack and release times and different thresholds
from the other channels.
• Depending on the material you may or may not want some channels to be compressed.
• Conversely you may want some channels to be compressed but not to contribute to the overall
compression.
• You may want channels to have different thresholds.
• With five speakers it is possible have signals panned so that they are the loudest signal in the room but
not the loudest signal in any one speaker.
The XLogic Multichannel Compressor is designed to give the engineer a flexible but easy to use set of tools to
deal with all these potential problems – and hopefully those we haven’t thought of yet.
4.1 Compressor Controls
The compressor sidechain controls
METER
MAIN/STEREO A
are straight forward and hopefully
require little explanation. The
ATTACK, RELEASE and RATIO
controls are six position switches:
the THRESHOLD and MAKEUP
GAIN controls are continuously
variable.
THRESHOLD
ATTACK - mS
RATIO
RELEASE - S
.4
.8
MAKE-UP
1
3
3
4
.3
10
2
.2
1.6
5
AUTO
0
.1
30 1.5
10
1
IN
dB
COMPRESSION
-20
+20
LFE/STEREO B
THRESHOLD
ATTACK - mS
RATIO
RELEASE - S
.4
.8
MAKE-UP
1
3
3
4
.3
10
2
.2
1.6
5
AUTO
0
.1
30 1.5
10
1
IN
LFE/
ST B
-20
+20
The compression meter at the left
of the unit normally displays gain
reduction for the Main (upper)
compressor. Pressing the LFE/STB switch shows the gain reduction for the LFE (lower) compressor.
4.2 Side Chain Adjust Section
The side chain adjust section is the key to the operation of the XLogic Multichannel Compressor. It
provides very flexible control of the compressor side chain.
S-CHAIN TRIM controls – These allow the contribution of their
respective channels to the side chain to be adjusted - effectively
SIDE CHAIN ADJUST
allowing different thresholds to be set for each input. They are
C
LEFT/RIGHT
CENTRE
indented at the ‘2 o'clock’ position (which is marked ‘0’) to allow
the trims to be easily set to the same level. When fully clockwise
they increase the side chain level by 10dB – effectively reducing
the threshold on that channel by 10dB. Turning a trim control
fully anti-clockwise removes that input from the side chain
completely.
An example may help: imagine the mix you are working on has
a number of loud sound effects in the surround channels. You
want the surround channels to follow the same compression as
0
0
L
R
ISO
LFE
MAX
+10
S-CHAIN TRIM
+10
S-CHAIN TRIM
LS
RS
LFE
SURROUND
0
0
LFE
LFE
0DB
LINK
ISO
+10
+10
S-CHAIN TRIM
S-CHAIN TRIM
the front channels, but don’t want the sound effects to compress the front channels. To achieve this simply
turn the side chain trim control on the Surround channels anti-clockwise.
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
The ISO switches isolate their respective channels from the compressor. When pressed that channel will
not contribute to the side chain and will not be affected by the compressor. It is still controlled by the
Master Fader and AutoFade controls.
Another example may help: your mix has low level stereo reverb placed in the surround channels. You
don’t want this to be affected by the front channels so you press the Surround ISO switch in.
The LFE LINK switch links the LFE channel to the main compressor - effectively turning the unit into a
single six channel compressor. This is useful if you want the LFE channel to be compressed with the main
mix. Turning down the LFE S-CHAIN TRIM control will stop the LFE signal compressing the rest of the
mix.
Alternatively (provided the LO PASS FILTER switch is released and the LFE 0DB switch is pressed) the
LFE channel can be used as a sixth full bandwidth channel for compressing the 6 main channels of a 6.1
mix.
The LFE LO PASS filter switch inserts a 120Hz low pass filter in the LFE side chain. This is useful if the
LFE channel is full bandwidth (if it is derived from the LCR channels for example) and prevents the low
frequency content being over compressed by higher frequency material.
Material that has been mastered for Dolby Digital™ or Dolby AC3™ release has the LFE level reduced by
10dB, as Dolby specify a gain of 10dB in the LFE speaker channel relative to the other channels. The LFE
side chain has 10dB more gain than the other channels to compensate for this. Other release formats (SACD
for example) run the LFE channel at the same level as the other channels. The LFE 0DB switch sets the LFE
side chain to the same gain as the other channels.
The MAX display consists of 6 bi-colour LEDs. These light yellow to show signal present (at approximately
-36dBu). When the compressor is active the LED corresponding to the channel that is applying the most
gain reduction will turn red.
4.3 Mode Section
This section contains two switches that radically change the operation of the compressor.
The DUAL STEREO switch reassigns the controls so that the lower set control the surround
channels and the upper set control left, centre, right and LFE channels. This can be used either
MODE
to provide separate compression of the surround channels or to allow the unit to be used as two
SIDE
CHAIN
SUM
separate compressors (one 4-channel, one stereo) when working on stereo material.
In normal operation the loudest signal will drive the compressor. With some material this may
not give the desired effect – if the lead guitar is panned to all five speakers it may well be the
loudest thing in the mix but not be the loudest thing on any one speaker channel. The SIDE
CHAIN SUM switch changes the operation of the compressor so that the side chain is derived
from a sum of the input signals. These are summed after being rectified to avoid phase
cancellation effects. In this mode the SIDE CHAIN TRIM trim controls control the contribution
of each input to side chain.
DUAL
STEREO
Note that if the LFE LINK switch is selected in this mode the LFE channel will be controlled by the upper
compressor but will not contribute to its side chain.
4.4 Fader Section
The final part of the compressor is the output fader section which provides overall
level control of the mix. This has two parts:
FADER
MASTER
• The MASTER fader and its associated IN switch provide overall level control of the
IN
mix. When the IN switch is off the fader control has no effect.
0dB
• The AUTOFADE switch and associated rotary control provides a timed fade down
or up with a fade time of 1 to 60 seconds. Pressing the switch will fade out the audio
in the time set on the associated control and releasing the switch will fade the audio
back up in the same time - the fade time can be adjusted at any time. The
AUTOFADE switch will be illuminated whilst the signal is fading down and will
remain illuminated until the signal has returned to normal gain.
RATE - Secs
10
30
6
AUTO
FADE
3
40
1
60
Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
Appendix A – Internal links and fuses
Fuses (Mains Inlet)
The mains inlet contains a single 1 amp 1.25" time delay fuse (SSL Part No. 35FJJ310). To change it disconnect the
mains inlet, then using a small screwdriver prise open the mains selector cover. This contains the fuse. Test and
replace with the same type and value if necessary.
Internal Fuses
The internal power rails are also individually fused. These fuses should only be changed by suitably experienced
staff. They are listed below
Fuses (629610X1 Power Regulator Card)
+48V FS-1 - 500mA wire ended (SSL part No. 35F5E250)
Fuses (629601X1 Main Card)
–18V FS1 - 3 amp wire ended (SSL part No. 35F5E330)
–15V FS2 - 3 amp wire ended (SSL part No. 35F5E330)
+15V FS3 - 3 amp wire ended (SSL part No. 35F5E330)
+18V FS4 - 3 amp wire ended (SSL part No. 35F5E330)
+5V FS5 - 3 amp wire ended (SSL part No. 35F5E330)
Links
LK3 Solder link. Links chassis and analogue 0V. Do not remove.
LK4 Links 0V of input and output XLRs to chassis. Normally fitted. Remove to capacitively couple.
LK5 Solder link. Links 0VA planes. Do not remove.
LK6 Solder link. Links digital and analogue 0V. Do not remove.
LK8 Not used
LK9 Not used
LK10 Normally audio passes through VCAs at all times. Removing LK10 will switch in the bypass
relays when all compressor IN and Master Fader IN switches are off. Normally fitted.
Appendix B – Connector Details
Audio Output
Audio Input
Location:
Rear Panel
Location:
Rear Panel
Conn' Type: XLR Male
Conn' Type: XLR Female
Pin
Description
Pin
Description
1
Chassis
1
Chassis
2
Audio +ve
Audio -ve
2
Audio +ve
Audio -ve
3
3
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
Appendix C – Performance Specification
Conditions
Source impedance 50Ω unless otherwise stated.
All measurements are RMS and are made using a 22Hz to 22kHz filter unless otherwise stated.
Noise
Input terminated with 50Ω. Compressor switched in and set for 0dB gain.
Noise
< 99dBu
Headroom
Headroom is defined at the output level at which THD exceeds 1%.
Headroom
> +26dBu output level, 20Hz to 20kHz at 0dB gain
> 125dB
Dynamic Range
Frequency Response
Measured reference level at 1kHz. Any gain setting. Source impedance 50Ω.
20Hz to 20kHz
10Hz to 96kHz
10Hz to 200kHz
0.05dB
+0.2/-0.5dB
+0.2/-2dB
Common Mode Rejection Ratio (CMRR)
Input level +20dBu, ground referenced.
20Hz to 10kHz
> 50dB
THD + Noise
Gain +0dB, input level +4dBu. Master Fader switched in. Compressor switched out.
10Hz to 20kHz (80kHz filter) < 0.006%, typically 0.003%
Gain +0dB, input level +20dBu. Master Fader switched in. Compressor switched out.
10Hz to 20kHz (80kHz filter) < 0.01%, typically <0.006%
THD with the compressor switched in is dependent on attack and release times and signal content.
Crosstalk
Channel to channel crosstalk, measured with one input terminated with 50Ω. All channels at 0dB gain.
Apply +20dBu test tone to any channel input except the one under test. Crosstalk is the ratio of level at the
output of the test channel and the output of the channel to which the signal is applied.
Crosstalk @ 50Hz
Crosstalk @ 1kHz
< –105dB
< –90dB
Impedance
Input Impedance
> 10kΩ
< 40Ω
Output Impedance
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
Appendix D - Calibration Information
The XLogic Multi Channel compressor is factory calibrated and should only need calibration if a potentiometer
or other component has been replaced or if it is suspected that there is a problem with calibration.
In all of the following instructions it is assumed that the lid has been removed and that power has been applied.
It is also assumed that unless otherwise specified, all switches are released and all potentiometers are at unity,
minimum or indent position as appropriate. The required accuracy for each adjustment will be specified along
with the target value.
All level and distortion measurements should be made with audio-band 20Hz to 20kHz filters unless otherwise
specified.
DC Calibration
Side Chain Trim Calibration
Equipment Required:
Unit Setup:
Digital Volt Meter
1. Ensure that all front panel switches are off and all controls are set fully anti-
clockwise, except for the Side Chain Trim pots which should be set to indent.
2. Reference the DVM to 0VA at TP42 on the lower card (629606).
Adjustment:
1. Measuring TP44 on the lower card (629606) – remove PL2 connector to access the
test point – adjust VR8 (AutoFade offset) for 0mV 0.5mV. Reconnect PL2
between the upper and lower cards.
2. Set the Left/Right S-Chain Trim on the front panel to indent. Measuring TP3 on
the upper card (629607), adjust VR6 on the upper card for –0.45V 10mV.
3. Set the Centre S-Chain Trim on the front panel to indent. Measuring TP4 on the
upper card (629607), adjust VR7 on the upper card for –0.45V 10mV.
4. Set front panel pot, Surround S-Chain Trim, to indent. Measuring TP43 on the
lower card (629606), adjust VR7 on the lower card for –0.45V 10mV.
5. Set front panel pot, LFE S-Chain Trim, to indent. Measuring TP39 on the lower
card (629606), adjust VR6 on the lower card for –0.45V 10mV.
Side Chain Gain Adjustment
Unit Setup:
Switch the Master Fader IN. Measure TP5 on the upper card (629607) and adjust
the Master Fader on the front panel for –2.00V 1mV (which equates to 40dB of
attenuation).
Adjustment:
1. Measuring TP47 on the lower card (629606), adjust VR10 for +2.00V 1mV.
2. Measuring TP45 on the lower card (629606), adjust VR9 for +2.00V 1mV.
3. Release the Master Fader IN switch.
Control Voltage Breakthrough Null
Unit Setup:
Select SIDE CHAIN SUM and press both compressor IN switches. Turn both
front panel THRESHOLD pots fully anti-clockwise.
Adjustment:
1. Measuring TP4 on the lower card (629606), adjust VR11 for 0V 10mV. Turn the
front panel Main/Stereo A Threshold pot fully clockwise – check that the
measurement remains within 10mV of 0V and re-adjust if necessary.
2. Turn the front panel Main/Stereo A Threshold pot fully anti-clockwise.
Measuring TP6 on the lower card (629606), adjust VR12 for 0V 10mV.
3. Turn the front panel LFE/Stereo B Threshold pot fully clockwise – check that the
measurement remains within 10mV of 0V and re-adjust if necessary.
4. Turn the front panel LFE/Stereo B Threshold pot fully anti-clockwise. De-select
the compressor IN switches and the SIDE CHAIN SUM switch.
Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
Distortion Null
Equipment Required:
Calibrated audio oscillator, audio distortion analyser and oscilloscope
Test Signal:
1kHz sinewave at +24dBu
Input and Output:
Oscillator to the Input of the channel being tested, Output to the distortion
analyser. Use the oscilloscope to monitor the measured signal.
Adjustment:
1. Connect the +ve input of the analyser to the test point as shown below and
connect the –ve input of the analyser to a 0VA test point. Note that the circuitry
at this point is balanced and so there are two measurements and two adjustments
per channel. Adjust for minimum THD (< 0.007%).
Input
Measure
TP31
TP32
TP29
TP30
TP27
TP28
TP21
TP22
TP23
TP24
TP25
TP26
Adjust
VR24
VR23
VR22
VR21
VR20
VR19
VR14
VR13
VR16
VR15
VR18
VR17
Left (+ve)
Left (–ve)
Right (+ve)
Right (–ve)
Centre (+ve)
Centre (–ve)
LFE (+ve)
LFE (–ve)
Left Sur (+ve)
Left Surr (–ve)
Right Surr (+ve)
Right Surr (–ve)
2. Finally, re-connect the analyser to each output in turn and adjust the +ve
distortion null to see if any reduction in THD can be achieved.
VCA Gain Adjust
Equipment Required:
Calibrated audio oscillator, audio level meter, oscilloscope and a (digital) DC
voltmeter
Test Signal:
1kHz sinewave at +20dBu
Input and Output:
Oscillator to the Input of the channel being tested, Output to the level meter. Use
the oscilloscope to monitor the measured signal.
Unit Setup:
Adjustment:
1. Switch the Master Fader IN.
2. Using the DVM, measure TP5 on the upper card (629607) and adjust the front
panel Master Fader for –2.00V 1mV (which equates to 40dB attenuation).
1. Connect the audio level meter to each output in turn. Measure each channel,
adjusting the appropriate preset for –20dBu 0.1dB (which equates to 40dB of
attenuation).
Input
Adjust
VR30
VR29
VR34
VR36
VR27
VR28
Left
Right
Centre
LFE
Left Surround
Right Surround
Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
Appendix E – Physical specification *
Depth:
325mm/12.8 inches not including heatsink
365mm/14.3 inches including heatsink
400mm/15.75 inches including connectors
Height:
89mm/3.5 inches (2 RU)
480mm/19 inches
Width:
Weight:
5kg/11 pounds
Power:
55 Watts/67 VA
Boxed size:
Boxed weight:
520mm x 520mm x 182mm (20.5" x 20.5" x 7.2")
7.3kg (16 pounds)
* All weights and dimensions are approximate
Appendix F – Environmental Specification
Temperature
Operating:
5 to 30 Deg. C
Non-operating:
Max. Gradient:
–20 to 50 Deg. C
15 Deg. C/Hour
Relative Humidity
Operating:
20 to 80 %
Non-operating:
Max. wet bulb:
5 to 90 %
29 Deg. C (non-condensing)
Vibration
Shock
Operating:
Non-operating, power off:
< 0.2 G (3 - 100Hz.)
< 0.4 G (3 - 100Hz.)
Operating:
Non-operating:
< 2 G (10mSec. Max.)
< 10 G (10mSec. Max.)
Altitude
Operating:
Non-operating:
0 to 3000m (above sea level)
0 to 12000m
Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
XLogic Multichannel Compressor Owner’s Manual
Notes
Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
|