Sharp Air Conditioner AFP80CX User Manual

AF-P80CX  
ROOM AIR CONDITIONER  
INSTALLATION AND OPERATION  
MANUAL  
CONTENTS  
PAGE  
FOR YOUR PROTECTION.................... 2  
CONSUMER LIMITED WARRANTY ..... 3  
INSTALLATION INSTRUCTIONS  
• CHECK WINDOW AREA ........................ 4  
• LOCATlON .............................................. 4  
• ACCESSORIES ...................................... 5  
• SUGGESTED TOOLS ............................ 5  
• INSTALLATION....................................... 6  
PRECAUTIONS  
CAUTION FOR USE ............................ 8  
• GROUNDING INSTRUCTIONS ........... 8  
• NOTES ON OPERATION .................... 9  
• ENERGY EFFICIENCY TIPS............... 9  
HOW TO OPERATE  
PARTS NAMES ...................................10  
COOLING OPERATION ......................11  
TO CHANGE TEMPERATURE SETTING .......... 11  
TO CHANGE FAN SPEED AND OPERATION MODE.. 12  
• ENERGY SAVER .................................13  
TO CHANGE AIR FLOW DIRECTION ....... 13  
This INSTALLATION AND OPERATION  
MANUAL explains the proper use of your new  
Sharp Air Conditioner. Read these instructions  
carefully before installing or operating your air  
conditioner. The INSTALLATION AND OP-  
ERATION MANUAL should be kept in a safe  
place for handy reference.  
• ON TIMER OPERATION .....................14  
• OFF TIMER OPERATION....................15  
• USING THE REMOTE CONTROL.......16  
• PLASMACLUSTER OPERATION........18  
CLEANING AND MAINTENANCE ........ 20  
BEFORE CALLING FOR SERVlCE...... 21  
As an ENERGY STAR Partner, Sharp Electronics has determined that this products (AF-P80CX) meet the  
ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners  
must be at least 10% more efficient than the minimum Federal standard.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONSUMER LIMITED WARRANTY  
CONSUMER LIMITED WARRANTY  
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"),  
when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option,  
either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to  
the purchaser for parts or labor for the period(s) set forth below.  
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor  
to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse,  
abnormal service or handling, or which has been altered or modified in design or construction.  
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof  
of purchase to the servicer.  
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL  
IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED  
TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long  
an implied warranty lasts, so the above limitation may not apply to you.  
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described  
herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.  
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive  
remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute  
complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute  
full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable,  
or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed  
by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential  
economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above  
exclusion may not apply to you.  
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM  
STATE TO STATE.  
AF-P80CX Room Air Conditioner. Be sure to have this information  
available when you need service for your Product.  
Your Product Model Number & Description:  
Warranty Period for this Product:  
One (1) year parts and labor from date of purchase. The warranty  
period continues for a total of five (5) years from date of purchase for  
the Sealed Cooling System parts; labor and service are not provided  
free of charge for this additional period.  
Additional Item(s) Excluded From  
Warranty Coverage (If any):  
Appearance items of the Product, knobs, filter, or accessories, mounting  
kit, seals, or any printed materials.  
Where to Obtain Service:  
From a Sharp Authorized Servicer located in the United States. To find the  
location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at  
1-800-BE-SHARP.  
What to Do to Obtain Service:  
Contact your Sharp Authorized Servicer to obtain in-home service for this  
Product. The Servicer will come to your home, and if it is necessary to  
remove the Product, the Servicer will reinstall it. Be sure to have Proof of  
Purchase available.  
OR CALL 1-800-BE-SHARP.  
SHARP ELECTRONICS CORPORATION  
Sharp Plaza, Mahwah, New Jersey 07430-2135  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
Before beginning installation, read these instructions carefully.  
Use the enclosed MOUNTING KIT for proper installation.  
CHECK WINDOW AREA  
The mounting kit is designed for wooden sill double or single hung sash-type windows.  
Minimum opening  
Mounting kit fully closed  
23 5/8" (600mm)  
Mounting kit fully opened  
(Without mounting kit)  
19 11/16" (500mm)  
7
35 /16" (900mm)  
Window opening from stool to lower  
sash bottom must be 14 27/32" (377mm)  
or more.  
Lower sash bottom  
Stool  
LOCATION  
• The air conditioner should be installed on a firm foundation to minimize noise and vibration.  
For safe installation, repairs, replacement and secure positioning, make sure foundation is  
solid and level.  
• The room air conditioner must be installed in an area within reach of a properly rated  
grounded outlet.  
• Use of extension cords of any kind is not recommended.  
• Never place any obstacles around air inlet.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
ACCESSORIES  
1
No.  
Accessories  
Q'ty  
1
1
2
3
Right closure assembly  
Left closure assembly  
Window sash foam seal  
2
1
1
3
4
Window sash foam seal  
(adhesive type)  
1
4
5
6
7
8
Bottom gasket  
1
7
6
2
1
2
Screws (L=1", 25.4mm)  
Screws (L= 13/32", 10mm)  
Base pan angle  
Remote control  
Battery  
5
6
7
6
7
9
10  
8
2
9
10  
2
SUGGESTED TOOLS  
1. Screw driver (medium size Phillips)  
2. Tape measure or ruler  
3. Knife or scissors  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
INSTALLATION  
WARNING: Make sure the unit is turned off and unplugged before working.  
Sash  
Cut the window sash foam seal (adhesive  
type) to the proper length and attach it to  
the underside of the window sash.  
1
Window sash foam seal  
(adhesive type)  
Jamb  
Sill  
Insert the right closure assembly and the  
left closure assembly into the top angle  
and the bottom channels.  
Secure the right and left closure to the  
cabinet with six of the provided screws.  
(L= 13/32", 10mm)  
2
3
Closure assembly  
Open the window sash and place the air  
conditioner on the sill.  
Balance the unit on the sill and close the  
window sash securely behind the top  
angle.  
WARNING:  
unit  
At this step, make sure the unit is inclined  
approximately 1 cm (3/8") to the back.  
If the unit is not properly inclined, the water  
collected in the bottom tray during opera-  
tion will not drain properly and may flow into  
the room where the air conditioner is in-  
stalled.  
sill  
incline backwards approximately  
1cm (3/8")  
Insert the bottom gasket into the space  
between the window sill and the bottom of  
the unit to seal outside air.  
4
If there is space between the bottom  
channel and the sill, fill the gap with a thin  
board or other hard filler.  
Bottom gasket  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
Closure assembly  
(Left)  
Insert the closure assemblies on both  
sides into the rails of the jamb.  
5
6
Jamb  
(Left)  
Indoor  
side  
Closure assembly  
(Left)  
Indoor  
side  
1/2 inches  
(13mm)  
Sill  
Stool  
Loosen screws on both sides of the  
cabinet, then hang the base pan angle  
on and secure the screws again.  
Secure the base pan angle to the sill by  
using the hole of the front side on the  
angle with one screw. (L=1", 25.4mm)  
7
8
Top angle  
Secure the top angle of the unit and the  
top of the closure assemblies to the sash  
with three of the provided screws. (L=1",  
25.4mm)  
And secure the bottom of the closure  
assemblies to the sill with two of the  
provided screws. (L=1", 25.4mm)  
Cut the window sash foam seal to the  
proper length and seal the opening be-  
tween the top of the inside window sash  
and the outside window sash.  
9
Window sash foam seal  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
PRECAUTIONS  
CAUTION FOR USE  
IMPORTANT: Points to keep in mind when using your air conditioner.  
Install the air conditioner by following the installation instructions given in the previous  
section of this manual.  
Make sure the unit is the correct capacity for the area you want to cool.  
Do not modify any part of this product.  
Do not insert objects into any part of the unit.  
Push the AC power plug securely into the receptacle and make sure it is not loose.  
Use power circuit with a proper voltage rating.  
Use a three-pronged grounded electrical outlet rated 125V, 60Hz,  
15 amp or more, AC only as shown on right.  
Use of an improper voltage rating power circuit can result in  
damage to the unit and possibly fire.  
Two-Pole, 3-wire Grounding  
Receptacle 15 Amps. 125V.  
Always use a fuse with the proper amp rating.  
Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse.  
Use of extension cords of any kind is not recommended.  
If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding  
type appliance extension cord rated 125 Volts, 15 amp or more.  
Ventilate the room periodically during use, especially if using gas appliances.  
GROUNDING INSTRUCTIONS  
WARNING: Improper use of the grounding plug can result in the risk of electric shock.  
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk  
of electric shock by providing an escape wire for the electric current.  
This appliance is equipped with a cord having a grounding wire with a grounding plug.  
The plug must be plugged into an outlet that is properly installed and grounded.  
WARNING: Do not under any circumstances cut or remove the round grounding prong  
from this plug.  
If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3-  
blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance.  
The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more.  
Consult a qualified electrician or serviceman if the grounding instructions are not completely under-  
stood, or if doubt exists as to whether the appliance is properly grounded.  
If a grounding adapter is used, make sure the receptacle box is fully grounded.  
Grounding adapter  
3-Pronged receptacle  
Grounded receptacle box  
Grounded  
receptacle box  
Grounding wire  
3-Pronged plug  
Screw  
Tab for grounding screw  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Grounding prong  
8
PRECAUTIONS  
NOTES ON OPERATION  
Allow 3 minutes for the compressor to restart cooling.  
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to  
restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for  
protection.  
If a power failure occurs during use, allow 3 minutes before restarting the unit.  
After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be  
sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three  
minutes, a protective device in the unit may cause the compressor to shut off. This protective device will  
prevent cooling for about 5 minutes.  
Memories of previous settings will be canceled and the unit will return to each initial setting.  
• Dehumidifying function  
The air conditioner removes moisture from the air in your room.  
Cooling operation under low temperatures: Is your unit freezing up?  
The unit operates on inside and outside temperatures. Freezing can occur when the temperature is set  
close to 64°F and when there are low outside temperatures, especially during the night hours. At these  
conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher  
temperature will prevent it from freezing.  
ENERGY EFFICIENCY TIPS  
Setting the proper temperature.  
For optimum energy efficiency, keep the difference between the inside and outside temperature within  
10°F(5°C). Do not keep the temperature setting any lower than is necessary for you to feel comfortable.  
Generally, 78°F to 80°F(26°C to 27°C) is a comfortable summer indoor temperature.  
When you turn the unit on, do not set the temperature higher than the room temperature at start up as  
this will not allow the compressor to cycle and maintain a comfortable room temperature.  
Avoid direct sunlight.  
Close blinds, drapes or shades to keep out direct sunlight during cooling operation.  
Keep the filter clean.  
Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air  
conditioner work harder and less efficiently. See page 20 on how to clean the filter.  
Turn off unnecessary light.  
Your air conditioner must remove the heat produced by your lights or other heat-producing appliances.  
Turn off lights or appliances that are not in use.  
Install your air conditioner in a shady location.  
Direct sunlight on a window air conditioner increases its workload and will increase its operating cost.  
Don't let cool air escape.  
Close windows and outside doors. Do not keep doors open and let hot air rush in. Improperly installed  
air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out.  
Turn off air conditioner when no one is home.  
Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
PARTS NAMES  
UNIT  
1Front Cabinet  
4
5
6
3
2Air Inlet (Indoor Side)  
3Horizontal Louvers  
4Vertical Louvers  
5Air Outlet (Indoor Side)  
6Control Panel  
7
8
7Rear Cabinet  
9
8Air Inlet (Outdoor side)  
9Filter (Pull the filter handle  
to the right to remove.)  
0Filter Handle  
10  
2
1
qPower Cord  
11  
CONTROL PANEL  
12  
2
1
F
hr  
COOL  
/
FAN TEMP  
3
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
7
9
11  
10  
4
5
6
8
1Receiver window for remote control signal  
2Display  
3SELECTOR indicator  
4SELECTOR pad  
6TIMER ON/OFF pad  
7TIMER indicator  
8ENERGY SAVER pad  
9ENERGY SAVER indicator  
0POWER ON/OFF pad  
qPOWER indicator  
5TEMPERATURE setting pad  
----Lower temp.  
----Raise temp.  
wPLASMACLUSTER indicator  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
COOLING OPERATION  
Touch POWER ON/OFF pad.  
POWER  
1
2
• The unit is preset at 74°F and HIGH  
COOL. This will show in the display  
when the power is first turned on.  
• POWER indicator and SELECTOR in-  
dicator (COOL) will light.  
indicator  
SELECTOR indicator  
F
hr  
COOL / FAN TEMP  
To turn off the unit, touch POWER  
ON/OFF pad again.  
• POWER indicator and SELECTOR  
indicator will go off.  
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
POWER ON/OFF pad  
TO CHANGE TEMPERATURE SETTING  
During cooling operation  
Touch the TEMPERATURE setting  
pad to adjust the temperature set-  
ting.  
F
hr  
COOL / FAN TEMP  
---Lower temp.  
---Raise temp.  
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
• Temperature can be set within the range  
of 64°F to 86°F.  
• Display will change as you touch  
the pad.  
TEMPERATURE setting pad  
NOTE:  
The latest temperature setting will be memorized and will appear on the display the next time  
the unit is turned on.  
• In cases of power outages or when the unit is disconnected; when the power is restored or the  
unit is plugged in, the unit and display will return to the preset conditions of 74°F and HIGH  
COOL. The unit will not automatically turn back on. The user must touch POWER ON/OFF to  
resume operation.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
TO CHANGE FAN SPEED AND OPERATION MODE  
SELECTOR indicator  
During operation  
Touch SELECTOR pad and select the  
F
operation mode and fan speed.  
hr  
• SELECTOR indicator and display will light  
in order as you touch.  
COOL / FAN TEMP  
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
HIGH COOL  
LOW FAN  
MED COOL  
MED FAN  
LOW COOL  
HIGH FAN  
SELECTOR pad  
NOTES ON OPERATION MODE:  
SELECTOR  
DISPLAY  
MODE  
Cooling operation with high fan speed.  
Cooling operation with medium fan speed.  
Cooling operation with low fan speed.  
Fan only operation with high fan speed.  
Fan only operation with medium fan speed.  
Fan only operation with low fan speed.  
HIGH COOL COOL  
COOL  
LOW COOL COOL  
MED COOL  
HIGH FAN  
MED FAN  
LOW FAN  
FAN  
FAN  
FAN  
• The latest operation mode will be memorized and the selector indicator and display will light  
when the unit is turned on.  
• In fan only operation, the temperature display will go off.  
• When the SELECTOR is changed to fan only operation from cooling operation, it will take 5  
seconds for the compressor to stop.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
ENERGY SAVER  
During normal operation, the thermostat automatically controls cooling and the fan runs continu-  
ously. When the ENERGY SAVER is selected, the thermostat automatically controls cooling and  
the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after  
the compressor stops. After the fan stops, the fan is programmed to rotate for approx. 2 minutes  
to detect room temperature. This will occur within a 20 min time span.)  
During cooling operation  
Touch ENERGY SAVER pad.  
1
F
• ENERGY SAVER indicator will light.  
hr  
COOL / FAN TEMP  
To cancel, touch ENERGY SAVER  
pad again.  
• ENERGY SAVER indicator will go  
off.  
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
2
ENERGY SAVER pad  
ENERGY SAVER indicator  
NOTE: ENERGY SAVER cannot be set during fan only (HIGH FAN, MED FAN, LOW FAN)  
operation.  
TO CHANGE AIR FLOW DIRECTION  
The horizontal louvers are used to adjust the UP / DOWN direction of air flow, and the vertical  
louvers are used to adjust the LEFT / RIGHT direction of air flow for uniform and efficient cooling  
of the room.  
Horizontal louvers  
Vertical louvers  
Lever  
Adjust UP/DOWN air flow  
Adjust LEFT/RIGHT air flow  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
ON TIMER OPERATION  
• This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance.  
You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance  
of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time.  
• The unit will start automatically according to your setting.  
When the unit is not operating  
SELECTOR indicator  
Touch the TIMER ON/OFF pad to set the  
1delayed start time.  
F
• The time setting will change as you touch the  
pad. The display will change as follows;  
hr  
COOL / FAN TEMP  
Preset(0.5h)  
Previous setting  
1.0h  
0.5h  
1.5h 10h  
12h 11h  
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
CL(cancel)  
TIMER ON/OFF pad  
TIMER indicator  
• The timer will be set, 5 seconds after the  
TIMER ON/OFF pad is touched for the last  
time.  
• SELECTOR indicator and TIMER indicator  
will light.  
(If you wish to start the operation  
6 hours and 30 minutes later, set  
the delay time as shown above.)  
• The time display will count down the remain-  
ing time.  
• The unit will start when the set time expires.  
The temperature setting will be displayed.  
TO CANCEL THE TIMER SETTING  
Touch the TIMER ON/OFF pad again after the  
timer is set, or press the TIMER ON/OFF pad  
until CL(cancel) appears on the display.  
NOTES FOR TIMER SETTING AND OPERATION:  
• After setting the TIMER, change the temperature and fan speed settings as shown on pages 11  
and 12. When the temperature is set in the timer mode, the temperature will show in the display  
for 5 seconds and then return to the time display.  
• The last setting used will be memorized and will appear on the display the next time you operate  
the unit with the TIMER function.  
• If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled  
and will not resume even after power is reinstated. The unit will not automatically start.  
• OFF TIMER OPERATION can also be set with the REMOTE CONTROL.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
OFF TIMER OPERATION  
• This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance.  
You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance  
of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time.  
• The unit will stop automatically according to your setting.  
When the unit is operating  
Touch the TIMER ON/OFF pad to set the  
1 delayed stop time.  
F
• The time setting will change as you touch the  
hr  
pad. The display will change as follows;  
COOL / FAN TEMP  
Preset(0.5h)  
Previous setting  
1.0h  
0.5h  
1.5h 10h  
12h 11h  
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
CL(cancel)  
• The timer will be set, 5 seconds after the  
TIMER ON/OFF pad is touched for the last  
time.  
TIMER ON/OFF pad  
TIMER indicator  
• TIMER indicator will light.  
• The time display will count down the remain-  
ing time.  
(If you wish to stop the operation  
10 hours later, set the delay time  
as shown above.)  
• The unit will stop when the set time expires.  
All indicators and displays will go out.  
TO CANCEL THE TIMER SETTING  
Touch the TIMER ON/OFF pad again after the  
timer is set or, press the TIMER ON/OFF pad until  
CL(cancel) appears on the display.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
USING THE REMOTE CONTROL  
INSTALLING BATTERIES  
Use two AA (R6) batteries.  
Remove the battery compartment cover.  
1
2
Insert the batteries in the compartment,  
Battery compart-  
ment cover  
making sure the  
and  
polarities  
are properly aligned.  
Replace the cover.  
3
NOTES:  
• The battery life is approximately one year with normal use.  
• When you replace the batteries, always use two new ones of the same type.  
• If the remote control does not operate normally after replacing the batteries, take out  
the batteries and replace them again after 30 seconds.  
• If you will not be using the unit for a long time, remove the batteries from the remote  
control.  
HOW TO USE THE REMOTE CONTROL  
Point the remote control towards the unit's receiver window and press the desired button.  
A beep will sound when the unit receives the signal.  
• Make sure no objects, such as curtains, block the receiver window.  
• The remote control operates from up to 20 feet (6 meters) away.  
• The beep will also sound when each pad on the control panel is touched.  
CAUTION:  
• Do not expose the receiver window to direct  
sunlight. This can adversely affect its operation.  
In such case, close the curtains to block the  
sunlight.  
• Use of a fluorescent lamp in the same room  
may interfere with the transmission of the  
signal.  
• The unit may be affected by signals emitted  
from the remote control of a television, VCR or  
other equipment used in the same room.  
• Do not leave the remote control exposed to  
direct sunlight or near a heater. Protect the  
remote control from moisture and shock which  
can discolor or damage it.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
OPERATING WITH THE REMOTE CONTROL  
TRANSMITTER  
PLASMACLUSTER button (See page 18)  
TEMPERATURE setting button  
TEMP.  
TEMP.  
---Raise temp. setting 1°F at a time.  
---Lower temp. setting 1°F at a time.  
ON / OFF  
HIGH COOL  
MED COOL  
LOW COOL  
SELECTOR button  
Push to change fan speed and operation  
mode.  
Fan speed and operation mode  
selections are shown to the right.  
TEMP.  
HIGH FAN  
MED FAN  
LOW FAN  
SELECTOR  
SET TIMER/OFF button  
Push to set delay "OFF" timer during operation.  
SET TIMER / OFF  
POWER ON/OFF button  
Push to start or stop the operation.  
POWER  
ON / OFF  
• The time setting will change as you push the button. The display  
will change as follows;  
Preset(0.5h)  
Previous setting  
1.0h  
0.5h  
1.5h  
10h  
CL(cancel)  
12h  
11h  
• The last OFF time setting is memorized by the unit and will  
appear on the display when the button is pushed.  
• The timer will be set, 5 seconds after the SET TIMER/OFF button  
is pushed for the last time.  
• If you wish to cancel the timer, push the SET TIMER/OFF button  
again after the time is set or, push the SET TIMER/OFF button  
until CL (cancel) appears on the display. A double beep will  
sound when the timer is cancelled.  
• The "ON" TIMER cannot be set with the remote control.  
It can only be activated by the TIMER ON/OFF pad on the unit's  
control panel ( See page 14 ).  
To change temperature setting when ON/OFF timer is in use  
1. Push a TEMPERATURE setting button.  
The current set temperature will be recalled on the unit's display.  
2. Use the TEMPERATURE setting buttons to set the new temperature.  
The new set temperature will show on the display for 5 seconds and return to  
the time display.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
PLASMACLUSTER OPERATION  
Cluster ions are released into the room, keeping air your room clean.  
During operation  
PLASMACLUSTER button  
Press PLASMACLUSTER button.  
1 • PLASMACLUSTER indicator will light.  
PLASMACLUSTER indicator  
ON / OFF  
TEMP.  
F
hr  
COOL / FAN TEMP  
SELECTOR  
ENERGY  
SAVER  
TIMER  
ON/OFF  
SELECTOR  
POWER  
ON/OFF  
SET TIMER / OFF  
POWER  
ON / OFF  
To cancel, press PLASMACLUSTER  
2 button again.  
• PLASMACLUSTER indicator will go off.  
NOTE:  
PLASMACLUSTER operation will be  
memorized when once set and will start its  
operation the next time the unit is turned  
on.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO OPERATE  
NOTE FOR PLASMACLUSTER OPERATION  
The ionizer inside the air conditioner will discharge cluster ions, which are  
collective mass of positive and negative ions, into the room.  
The cluster ions reduce airborne mold fungus and deodorize/decompose odor-  
causing molecules.  
Cluster ions  
Ionizer  
Mold fungus  
Odor  
Reduce, deodorize, decompose  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING AND MAINTENANCE  
CLEANING THE FILTER  
If the filter is clogged with dust, the amount of air flow will  
be reduced, resulting in poor cooling performance. The  
filter should be cleaned every 10 days. At the beginning of  
every cooling season or after a long period of inactivity,  
clean the filter before starting the unit.  
REMOVE THE FILTER  
1
Gently pull the filter handle to the right and slide the  
filter out from the unit.  
CLEAN THE FILTER  
2
To remove dust from the filter, use a vacuum cleaner  
or wash it in clean water.  
If the filter is very dirty, wash it with detergent and  
rinse carefully with clean water. Dry the filter with  
a soft cloth.  
Do not expose the filter to heat or dry it in direct  
sunlight.  
RE-INSTALL THE FILTER  
3
Align the filter behind the front panel.  
Grasp the filter handle and gently push the filter back  
into place.  
Never operate the unit without installing the filter. It  
may result in serious damage to the unit.  
CLEANING OF THE FRONT PANEL AND CABINET  
To clean the front panel and cabinet, wipe with a soft, dry cloth or with a cloth moistened with a  
mild soap. Rinse carefully by wiping with a damp cloth and dry completely.  
Avoid splashing the unit with water. Excess water can damage electrical insulation and result in  
danger.  
Never use harsh chemicals or abrasive cleaners on any part of the unit. To avoid damage to the  
unit, do not use hot water (120°F / 50°C or more) when cleaning.  
OILING OF THE COMPRESSOR AND FAN MOTOR IS  
UNNECESSARY  
The compressor is permanently lubricated and is hermetically sealed. The fan motor is  
lifetime sealed and does not require oiling.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE CALLING FOR SERVlCE  
IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK  
THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE.  
AIR CONDITIONER DOES NOT OPERATE AT ALL  
• Is the unit plugged in or is the plug loose?  
• Is the fuse blown or the circuit breaker tripped?  
• Did you restart the unit within 3 minutes after a power failure? If the power was off  
for less than 3 minutes, and you restarted the air conditioner within 3 minutes, a  
protective device may cause the compressor to shut off, preventing cooling for  
about 5 minutes.  
AIR CONDITIONER DOES NOT PROPERLY COOL  
• Is the SELECTOR set to fan only (HIGH FAN, MED FAN, LOW FAN) mode?  
Cooling will not take place in the fan only mode. Change the SELECTOR setting.  
• Is the filter clogged with dust?  
A dirty filter can cause the cooling coils to freeze. If this happens, clean the filter  
and replace. Run the air conditioner on the MED FAN setting until all ice  
dissipates.  
• Is the temperature set properly?  
If your room is too warm, adjust the temperature setting lower.  
If your room is too cool, adjust the temperature setting higher.  
• Is the window exposed to direct sunlight?  
Close curtains or blinds to minimize solar energy heating the room.  
• Are the windows or doors open?  
Close all windows and doors for maximum cooling.  
ODOR EMITTED FROM THE PLASMACLUSTER AIR OUTLET  
This is the smell of ozone generated from the ionizer. Density of the ozone is very  
little, having no adverse effect over your health. The ozone discharge into the air  
will decompose soon, and its density in room will not increase.  
A LOW BUZZ NOISE EMITTED  
This is a sound emitted when the unit is generating ion clusters.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE CALLING FOR SERVlCE  
TIMER DOES NOT WORK PROPERLY  
• If a power failure occurs while the ON or OFF TIMER is set, the TIMER setting will  
be cancelled and will not resume even after the power is reinstated. This is the  
normal operation for this unit.  
NOTE: WATER IN BOTTOM OF TRAY  
• Water will collect in the bottom tray of the unit. This is normal. Water condenses on  
the evaporator coil at the front of the unit and is channeled to the rear where it is  
picked up by the condenser fan. The water is blown onto the condenser coil fins and  
this creates a "splashing" noise which is normal. If excess water builds up in this tray  
it will drain outside through a grooved channel in the tray.  
SOUNDS  
• The operating sound may seem rather loud for 2 to 3 minutes when the unit is first  
turned on. This is the sound of the compressor's start-up and is normal.  
• A soft, swishing noise can be heard immediately after the unit is turned on or off, and  
also during operation. This is the sound of the refrigerant flowing inside the unit.  
IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL  
• Check the remote control batteries. Replace if necessary.  
• Try to send the signal again with the remote control pointed directly at the unit's  
receiver window.  
• Check whether the remote control batteries are installed with the polarities properly  
aligned.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHARP ELECTRONICS CORPORATION  
Sharp Plaza, Mahwah, New Jersey 07430-2135  
SHARP CORPORATION  
Osaka, Japan  
Printed in Thailand  
TINSEA318JBRZ 02AO  
TL  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Flat Panel Television LC 15SH1M User Manual
Sharp Toaster KZ 2S01SS User Manual
Shure Hair Dryer 27C3166 User Manual
Shure Microphone PG58BTS User Manual
Snapper Snow Blower 1694921 User Manual
Sony Camcorder PDW F330L User Manual
Sony Headphones DR BT21G User Manual
Sony MiniDisc Player MDX CA680 User Manual
Sony MiniDisc Player MZ R91 User Manual
Speco Technologies Portable Speaker SP 5AWD T User Manual