Cell Type HR-AAUL
Specifications
Type : Nickel-Metal Hydride Battery
Size : AA
Typical
1450mAh
Capacity
1)
Minimum
1300mAh
14.2 mm
Nominal Voltage
1.2V
Charging Current x Time
Fast Charge
Fast Charge
2)
2)
1450 mA x about 1.1h
0°C - 40°C
Charge
Condition
Discharge Condition
0°C - 50°C
49.0 mm
Less than
30days
Ambient Temp.
-20°C - 50°C
-20°C - 40°C
-20°C - 30°C
About 25mΩ(at 1000Hz)
Storage
Condition
Less than
90days
Less than
1year
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Weight
4)
About 27 g
Size
4)
:(Diameter) x (Height)
14.2(D) x 49.0(H) mm
1)Single cell capacity under the following condition.
Charge : 145mA×16h, Discharge : 290mA(E.V.=1.0V) at 20°C
2)Use recommended charging system.
3)After a few charge and discharge cycles under the above 1) condition.
4)With tube.
D
H
14.2 mm
49.0 mm
Dimensions
(with tube)
Typical Characteristics
Charge
Discharge
1.6
1.8
1.7
1.6
1.5
1.4
1.3
Charge : 1200mA (-∆V=10mV)
Rest : 1h
Discharge : 240mA, 1200mA, 2400mA (E.V.=1.0V)
Ambient Temp. : 20°C
1.5
0°C
1.4
20°C
40°C
240mA
1.3
1.2
1200m
1.1
1.2
Charge : 1200mA (-∆V=10mV)
2400mA
Ambient Temp. : 0°C,20°C,40°C
1.0
1.1
1.0
0.9
0
10
20
30
40
50
60
70
80
90
0
200 400 600 800 1000 1200 1400 1600 1800
Charge Time (min)
Discharge Capacity (mAh)