ROOF CAP
INSTALL THE DUCTWORK
8" ROUND
DUCT
NOTE: To reduce the risk of fire, use only
steel ductwork.
1. Decide where the ductwork will run between
the hood and the outside.
2. A straight, short duct run will allow the hood
to perform most efficiently.
3. Long duct runs, elbows, and transitions will
reduce the performance of the hood. Use as
few of them as possible.
8" ROUND
ELBOW
EAVE
VENT
DECORATIVE
FLUE
HOOD
4. Install a roof or wall cap. Connect 8" round
steel ductwork to cap and work back towards
hood location. Use duct tape to seal the joints
between ductwork sections.
24" TO 30" ABOVE
COOKING SURFACE
93/16”
CROSS
FRAMING
INSTALL SUPPORT SYSTEM
1. At hood location, install 2 X 4 cross framing
between ceiling joists using dimensions
shown.
2. Finish the ceiling surface. Be sure to mark
the location of the ceiling joists and cross
framing.
CEILING
JOISTS
SUPPORT
FRAME
OPENING
3. Position upper half of support frame so that
the support frame opening is on the short
side of the hood.
HEIGHT
ADJUSTMENT
SLOTS
UPPER
HALF OF
SUPPORT
FRAME
4. Secure the upper half of support frame to
joists and cross framing with four screws pro-
vided. Make sure screws are driven into cen-
ter of joists and framing for maximum
strength.
CROSS
FRAMING
5. Adjust the overall height of the support frame.
Loosen and re-tighten the screws in the
height adjustment slots as necessary. Note
that the hood height is 10¼” and that the
bottom of the hood must be 24” min. and 30”
max. above the cooktop.
93/16”
TOP VIEW
OF
SUPPORT
FRAME
713/16”
TYPICAL
SUPPORT
FRAME
MOUNTINGS
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECT DECORATIVE FLUE
1. Secure the upper decorative flue section
to the upper support frame.
UPPER
DECORATIVE
FLUE
2. Temporarily hang the lower decorative flue
section from the support frame.
SECTION
LOWER
DECORATIVE
FLUE
SECTION
INSTALL DUCT CONNECTOR
DUCT
CONNECTOR
1. Secure the duct connector to the top of the
hood using four (4) screws, supplied.
MOUNT HOOD TO SUPPORT
FRAME
NUT
1. Insert four (4) bolts through the top of the
hood - from the inside.
2. Use four (4) nuts to secure hood to support
frame as shown.
BOLT
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING
WIRING BOX
COVER
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical
codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Feed 6" of power cable through the knock-
out opening and secure cable to the wiring
box with an appropriate connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.
CONNECT DUCTWORK
1. Use 8" round steel duct to connect the duct
collar on the hood to the ductwork above.
2. Use duct tape to make all joints secure and
air tight.
LOWER
DECORATIVE
FLUE
3. Slide the lower decorative flue section
downward, until it fits properly around hood.
SECTION
8”
4. Secure decorative flue to hood with screws
provided.
ROUND
STEEL
DUCT
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
Grease Filters
The grease filters should be cleaned frequently.
Use a warm detergent solution. Grease filters
are dishwasher safe.
Remove filters by pushing filters towards the
back of hood and rotating filters downward.
GREASE FILTERS
Hood Cleaning
Stainless steel is one of the easiest materials to keep clean. Occasional care will help
preserve its fine appearance.
Cleaning tips:
• Hot water with soap or detergent is all that is usually needed.
• Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to
avoid water marks.
• For discolorations or deposits that persist, use a non-scratching household cleanser
or stainless steel polishing powder with a little water and a soft cloth.
• For stubborn cases, use a plastic scouring pad or soft bristle brush together with
cleaser and water. Rub lightly in direction of polishing lines or "grain" of the stain-
less finish. Avoid using too much pressure which may mar the surface.
• DO NOT allow deposits to remain for long periods of time.
• DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere
to the surface causing rust.
• DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to
remain in contact with stainless steel for extended periods. Many of these com-
pounds contain chemicals which may be harmful. Rinse with water after exposure
and wipe dry with a clean cloth.
Painted surfaces should be cleaned with warm water and mild detergent only.
OPERATION
BLOWER
ON / OFF
SWITCH
LIGHT
SWITCH
BLOWER
SPEED
CONTROL
Controls
The hood is operated using the slide controls
under the front edge of the hood.
The light switch turns the halogen lights on
and off.
The blower on / off switch turns the blower on
to the running speed set by the blower speed
control. The blower must be turned on and off
using this switch.
PILOT
LAMP
The blower speed control changes the run-
ning speed of the blower. It is infinitely adjust-
able from low to high speed.
The pilot lamp lights up whenever the blower
is on.
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
HALOGEN BULBS
This range hood requires four (4) halogen bulbs
(Type T4, 12V, 20W).
To change bulbs:
1. Open the light lens by grasping the tab on
TAB
the lens and rotating lens downward.
LIGHT LENS
2. Remove the bulb by pulling sideward (Do not
rotate). CAUTION: BULB MAY BE HOT!
3. Do not touch replacement bulb with bare
hands! Push bulb securely into lamp socket
and snap lens closed.
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period of
one year from the date of original purchase. THERE ARE NO OTHER WAR-
RANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,
IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR APAR-
TICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use
and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START-
ERS AND TUBES. This warranty does not cover (a) normal maintenance and
service or (b) any products or parts which have been subject to misuse, neg-
ligence, accident, improper maintenance or repair (other than by Broan), faulty
installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as speci-
fied for the express warranty. Some states do not allow limitation on how long
an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION,
SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER
THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CON-
NECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not
allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior war-
ranties.
To qualify for warranty service, you must (a) notify Broan at the address stated
below or telephone: 1-800-637-1453, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part.
At the time of requesting warranty service, you must present evidence of the
original purchase date.
BROAN MFG. CO., INC., 926 West State Street Hartford, WI 53027
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
63000 SERIES RANGE HOOD
KEY NO.
PART NO.
DESCRIPTION
6
9
14
19
26
30
48
49
53
57
68
69
86
B02000191
B08087485
B02300730
B03295005
B02300722
B03292291
B02310094
B03295000
B03202007
BE3300527
B02011064
B02011063
B08088242
BE3334373
B03202433
BE3495228
BE3334252
BE3407823
BE3407816
B03109013
B03109014
B03292287
BR2300134
B03292161
B08086101
B03292162
B03292163
B02300729
B03292294
B02300719
B03295006
B06001772
Filter Spring
Grease Filter
Motor Capacitor
Terminal Box
Halogen Lamp Bulb
Switch Cover
Motor
Blower Wheel
Rubber Washer
Damper Flap
Right Blower Housing
Left Blower Housing
Duct Connector
Filter Channel
Nameplate
99
113
115
116
118
119
124
125
144
147
165
166
167
168
208
223
474
477
*
Wiring Box
Wiring Box Cover
Decorative Flue Bottom
Decorative Flue Top
Support Frame Bottom
Support Frame Top
Wire Clamp
Terminal Block
Control Board Box
Control Board
Control Board Box Cover
Capacitor Box Cover
Transformer
Switch Button
Halogen Lamp Housing
Terminal Cover
Blower Assembly (Includes Key Nos. 48, 49,
53, 68, 69)
*
B06106298
Control Board Assembly w/ Circuit Board
(Includes Key Nos. 144, 147, 165, 166, 167,
168)
*
*
*
B06106297
B06106294
B080810199
Switch Assembly (Includes Key Nos. 222, 223,
224, 225, 226, 228, 229, 230)
Motor Capacitor Assembly w/ Wires
(Includes Key No. 14 & Wires)
Duct Connector Assembly
(Includes Key Nos. 57 & 86)
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
63000 SERIES RANGE HOOD
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|