Radio Shack Surge Protector 61 2422 User Guide

9/1WVNGV"%QORWVGT"'SWKROGPV"5WTIG"2TQVGEVQT"5VTKR  
61-2422  
OWNER’S MANUAL — Please read before using this equipment.  
Thank you for purchasing the RadioShack 7-Outlet Computer Equipment Surge Protector  
Strip. It protects your valuable equipment from damage caused by sudden electrical spikes  
and surge. Your surge protector absorbs electrical spikes and power surges and ensures  
steady performance of connected devices by filtering electromagnetic and radio frequency  
interference. .  
%106'065  
The FCC Wants You to Know ..................... 1  
Safety Precautions ...................................... 2  
Mounting the Surge Protector ..................... 2  
Connections ................................................ 2  
Connecting a Telephone Line .................. 2  
Connecting Computer Network  
Surge Protected Modular  
Phone Jacks — RJ-11  
connections provide protection  
against surges from a connected  
Swift Detection and Protection — Detects and protects against a  
power surge of up to 6,000 volts and 90,000 amps within 1  
nanosecond (1 billionth of a second).  
Equipment ................................................ 2  
Connecting AC Power .............................. 2  
Using the Safety Slide Cover ................... 2  
Using the Indication Tags ......................... 3  
Operation .................................................... 3  
Troubleshooting .......................................... 3  
Care ............................................................ 3  
Service and Repair ...................................... 3  
Specifications .............................................. 4  
fax / modem.  
POWER — Press to turn the  
surge protector on.  
Safety Alarm — Alerts  
AC Adapter Spacing  
RESET — See  
“Troubleshooting” on  
Page 3.  
you when the AC line is  
no longer protected  
(surge protector stops  
conducting power).  
Lets you plug an AC  
adapter into your surge  
protector.  
"+/2146#06"  
#
#
If an icon appears at the end of a paragraph,  
go to the box on that page with the  
corresponding icon for pertinent information.  
— Warning  
— Important  
#
Rý  
. — Caution  
± — Note  
Safety Slide Covers —  
Prevent children from  
Safety ON  
inserting metal objects into  
the unused AC socket(s).  
."%#76+10".  
• This product is intended for indoor use only.  
Safety OFF  
• This surge protector is not a lightning  
arrestor and might not protect against  
lightning-induced voltage surges.  
GROUNDED WHEN LIT  
Indicator — Lights when the  
connected devices are  
properly grounded.  
Power ON Indicator — Lights  
when the surge protector’s  
power is turned on.  
PROTECTED WHEN LIT  
Indicator — Lights when the  
connected devices are protected.  
• Be sure the total wattage of all connected  
devices does not exceed 1,875 watts.  
• Use the surge protector only with a three-  
prong standard AC plug. The surge protector  
cannot provide protection without a  
grounded AC source.  
Indication Tags — Identify which device’s power cord is connected to which  
AC socket, so you can avoid disconnecting the wrong device.  
Power Shutdown Protection — Protects the connected appliances from being damaged by shutting  
down power when surge protection is depleted (see “Troubleshooting” on Page 3).  
We have designed your surge protector to  
conform to federal regulations, and you can  
connect it to most telephone lines. However,  
each surge protector that you connect to the  
telephone line draws power from the  
telephone line. We refer to this power draw  
as the device's ringer equivalence number,  
or REN.  
6*'"(%%"9#065";17"  
61"-019  
Your surge protector complies with Part 68  
of FCC Rules. You must, upon request,  
provide the FCC registration number and the  
REN to your telephone company.  
You must not connect your surge protector  
to:  
If you use more than one phone or other  
device on the line, add up all of the RENs. If  
the total is more than five (three in rural  
areas), your telephones might not ring. If  
ringer operation is impaired, remove a  
device from the line.  
• coin-operated systems  
• party-line systems  
• most electronic key telephone systems  
© 2002 RadioShack Corporation.  
All Rights Reserved.  
RadioShack and RadioShack.com are trademarks  
used by RadioShack Corporation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROTECTED WHEN LIT, ON and  
GROUNDED WHEN LIT indicators will not  
light, replace the surge protector..  
75+0)"6*'"+0&+%#6+10"6#)5  
."%#76+10".  
Retain Instructions— Retain the safety and  
Your surge protector comes with pairs of  
indication tags to help you identify which  
device’s power cord is connected to which  
AC socket. Stick a large tag on the power  
cord at the rear of the device and the same  
color small tag next to the surge protector’s  
target AC socket.  
operating instructions for future reference.  
Damage — Unplug this appliance from the wall  
outlet and replace it:  
%#4'  
Keep the surge protector dry; if it gets wet,  
wipe it dry immediately. Use and store the  
surge protector only in normal temperature  
environments. Handle the surge protector  
carefully; do not drop it. Keep the surge  
protector away from dust and dirt, and wipe  
it with a damp cloth occasionally to keep it  
looking new.  
• When the power cord or plug is damaged.  
• If liquid has been spilled or objects have  
fallen into the appliance.  
• If the appliance has been exposed to rain or  
water.  
12'4#6+10  
Press POWER to turn on the surge  
• If the appliance has been dropped or  
damaged in any way.  
±
protector.  
• When the PROTECTED WHEN LIT indicator  
fails to light.  
Your connected devices are protected when  
the PROTECTED WHEN LIT, ON and  
GROUNDED WHEN LIT indicators light.  
5'48+%'"#0&"4'2#+4  
If your surge protector is not performing as it  
should, take it to your local RadioShack  
store for assistance. Modifying or tampering  
with the surge protector’s internal  
±"016'"±"  
If any of the indicator lights fail, see  
“Troubleshooting”.  
When you are not using the surge protector,  
press POWER so it pops up to turn off the  
surge protector. The PROTECTED WHEN LIT,  
ON, and GROUNDED WHEN LIT indicators  
turn off.  
components can cause a malfunction and  
might invalidate its warranty.  
6417$.'5*116+0)  
Condition  
The GROUNDED WHEN LIT indicator does  
not light.  
Solution  
Your surge protector is not grounded. You  
must move it to a different grounded, three-  
prong AC outlet.#ý  
"+/2146#06"  
#
#
f the GROUNDED WHEN LIT still does not  
light after moving the surge protector to a  
grounded oultet, return the product to  
RadioShack for assistance.  
Operating this surge protector from a non-  
grounded outlet will invalidate your “Connected  
Equipment Guarantee” and puts your valuable  
equipment at risk.  
If the surge protector proves to be working  
properly, you may need to contact a  
professional electrician to check your outlets  
for proper grounding.  
Condition  
The PROTECTED WHEN LIT, ON and  
GROUNDED WHEN LIT indicators turn off,  
and RESET pops out.  
Solution  
Your surge protector received a current that  
exceeded its capacity due to overload.  
When this happens, the 15-amp circuit  
breaker (located on the side of the case)  
trips to prevent possible damage, and  
RESET pops out. To reset the surge  
protector, disconnect one or more of the  
connected devices and allow the surge  
protector to cool down. Then push RESET in.  
Condition  
The PROTECTED WHEN LIT, ON and  
GROUNDED WHEN LIT indicators turn off,  
and the surge protector sounds an alarm.  
Solution  
Your surge protector's AC line is no longer  
protected from surges and power is not  
allowed to pass beyond the alarm. When the  
surge protector receives an unusually strong  
surge, the built-in protection absorbs the  
surge to protect your equipment. If the surge  
is strong enough, it diminishes the  
protection circuitry’s ability and the surge  
protector sounds an alarm. If the  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
52'%+(+%#6+105  
Line Voltage ............................................................................................................................................................................................................................125V  
Line Current ..............................................................................................................................................................................................................................15A  
Frequency ..............................................................................................................................................................................................................................60Hz  
Number of AC Outlets ..................................................................................................................................................................................................................7  
Cord Length/Plug Type .................................................................................................................................................................................... 7ft, right angle plug  
Circuit Breaker ..........................................................................................................................................................................................................................15A  
Housing Material ................................................................................................................................................................................................................. Plastic  
PROTECTED WHEN LIT Indicator ............................................................................................................................ Lights green when the AC line is protected  
GROUNDED WHEN LIT Indicator ...................................................................................................... Lights green when the ground wire is securely connected  
Power On Indicator ..................................................................................................................... Lights green when the surge protector’s AC power is turned on  
Noise Frequency Range ................................................................................................................................................................................. 100 kHz – 100 MHz  
Noise Attenuation Level ...............................................................................................................................................................................................Up to 40dB  
Maximum Surge Voltage .....................................................................................................................................................................................................6,000V  
Composite Maximum Surge Current ...........................................................................................................................................................120VAC Line 90,000A  
Phone Line ........................................................................................................................................................................................................................10,500A  
Total Maximum Surge Current .........................................................................................................................................................................................100,500A  
Composite Maximum Energy Dissipation:  
120 VAC Line ....................................................................................................................................................................................................................... 1,851J  
Phone Line .............................................................................................................................................................................................................................. 180J  
Total Maximum Energy Dissipation ..................................................................................................................................................................................... 2,031J  
Number of Lines Protected .............................................................................................................................. Three (Hot-Neutral, Hot-Ground, Neutral-Ground)  
Clamping Time ...................................................................................................................................................................................................... <1 nanosecond  
Clamping Voltage ...................................................................................................................................................................................................................330V  
Additional Protect ...........................................................................................................................Fax, Modem (1 in, 1 out) Tip-Ground, Ring-Ground, Tip-Ring  
Operation Temperature ............................................................................................................................................................................ 32 to 122°F (0 to 50°C)  
UL Approvals .................................................................................................................................................................................................... UL1449 & UL1363  
FCC Certification ................................................................................................................................................................................................................ Part 68  
Specifications are typical; individual units might vary. Specifications are subject to change and improvement without notice.  
LIMITED FIVE-YEAR WARRANTY AND CONNECTED EQUIPMENT GUARANTEE  
LIMITED WARRANTY — This surge protector product is warranted by RadioShack to the original purchaser against manufacturing defects in material and workmanship under normal use for five (5) years from the date of  
purchase (the “Warranty Period”) from RadioShack company owned stores and authorized RadioShack franchisees and dealers. In the event of a covered product defect during the Warranty Period, RadioShack will, at its  
option, unless otherwise provided by law: (a) correct the defect by surge protector repair without charge for parts and labor; (b) replace the surge protector with one of the same or similar design; or (c) refund the purchase  
price of the surge protector.  
CONNECTED EQUIPMENT GUARANTEE — RadioShack warrants to the original purchaser of the surge protector that if any electronic equipment (the “Connected Equipment”), which is properly installed and connected  
(as defined below) to the surge protector and is damaged during the Warranty Period by a transient voltage surge/spike from the AC power line, telephone line or coaxial line that enters the Connected Equipment through  
the surge protector, RadioShack will reimburse to the original purchaser of the surge protector the lower of the: (a) Connected Equipment repair charges; (b) purchase price of equipment comparable (as determined by  
RadioShack) to the Connected Equipment; or (c) original purchase price of the Connected Equipment, up to a maximum of fifty thousand U.S. dollars ($50,000.00) (the “Equipment Limit”). The Connected Equipment Guar-  
antee does not cover data loss or any other damages excluded in the all capitalized paragraph below. In order to qualify for Connected Equipment reimbursement, the surge protector must be returned to RadioShack and  
inspection of the surge protector must show its protection capacity was exhausted by a surge. “Properly installed and connected” means the surge protector must be plugged directly into a properly wired and grounded AC  
outlet; no extension cords, adapters, other ground wires or electrical connections may be used to connect the surge protector to AC power and no more than one piece of Connected Equipment may be connected to any  
one surge protector outlet. The wiring in the building must comply with all applicable codes (NEC, CSA, etc.), and all wires (power, telephone and coaxial) leading into the Connected Equipment must pass through the  
surge protector. To claim damage to Connected Equipment as a result of telephone line transients, the surge protector must provide telephone line protection, and your telephone service equipment must include a properly  
installed and operating “primary protection” device at the service entrance. Primary protection devices are normally available from the telephone company and added during telephone line installation. To claim damage to  
Connected Equipment as a result of coaxial line transients, the surge protector must provide coaxial line protection.  
This Limited Warranty and Connected Equipment Guarantee applies only to the original purchaser of the surge protector.  
EXCEPT AS PROVIDED HEREIN, RADIOSHACK MAKES NO EXPRESS WARRANTIES AND ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-  
POSE, ARE LIMITED IN DURATION TO THE DURATION OF THE WRITTEN LIMITED WARRANTIES CONTAINED HEREIN. EXCEPT AS PROVIDED HEREIN, RADIOSHACK SHALL HAVE NO LIABILITY OR  
RESPONSIBILITY TO CUSTOMER OR ANY OTHER PERSON OR ENTITY WITH RESPECT TO ANY LIABILITY, LOSS OR DAMAGE CAUSED DIRECTLY OR INDIRECTLY BY USE OR PERFORMANCE OF THE  
PRODUCT OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY OR CONNECTED EQUIPMENT GUARANTEE, INCLUDING, BUT NOT LIMITED TO, ANY DAMAGES RESULTING FROM INCONVE-  
NIENCE, LOSS OF TIME, DATA, PROPERTY, REVENUE, OR PROFIT OR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, EVEN IF RADIOSHACK HAS BEEN ADVISED OF THE POS-  
SIBILITY OF SUCH DAMAGES.  
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.  
To make a claim for surge-induced damage to Connected Equipment, you must:  
1. Call RadioShack at 1-888-353-1560 for a return authorization number during the Warranty Period. Under no circumstances will a claim for surge-induced damage to Connected Equipment be accepted without a return  
authorization number;  
2. Have any surge-induced, damaged Connected Equipment repaired (or get an estimate for repair) by a service center authorized by the manufacturer of the Connected Equipment unless the service center determines  
that the Connected Equipment is not repairable or that the cost of repair will be more than the purchase price of comparable replacement equipment. If the Connected Equipment is not to be repaired, get a written quo-  
tation for the purchase price of comparable replacement equipment. In no event will RadioShack reimburse more than the Equipment Limit. The repair bill or estimate from the authorized service center must indicate  
that the damage to the Connected Equipment was surge-induced; and  
3. Ship the original surge protector, postage prepaid to: RadioShack, 7020 Koll Center Pkwy, Suite 136, Pleasanton, California, 94588. Include: (a) your name, address and daytime telephone number; (b) the original or a  
photocopy of the sales receipt for the surge protector; (c) a brief description of any problem with the surge protector; (d) a brief description of how the damage to the Connected Equipment occurred; (e) the original au-  
thorized service center repair bill or estimate documenting that the damage to the Connected Equipment was surge-induced; and (f) if replacement equipment is to be purchased, the original or a photocopy of the quo-  
tation for comparable replacement equipment and the authorized service center repair estimate must contain a statement that the Connected Equipment is not repairable or that the cost of repair will be more than the  
purchase price of comparable replacement equipment.  
If RadioShack determines that damage to Connected Equipment is covered, RadioShack will reimburse, up to the Equipment Limit amount defined above, to the original purchaser of the surge protector the lower of the:  
(a) repair charges; (b) purchase price of comparable replacement equipment; or (c) the original purchase price of the Connected Equipment. In addition, in the event of a covered product defect during the Warranty Period,  
RadioShack will, at its option, unless otherwise provided by law: (a) correct the defect by surge protector repair without charge for parts and labor; (b) replace the surge protector with one of the same or similar design; or  
(c) refund the purchase price of the surge protector.  
To make a warranty claim for a defect in the surge protector without a claim for surge-induced damage to Connected Equipment, you must, during the Warranty Period, take the surge protector and the RadioShack sales  
receipt as proof of purchase date to any RadioShack store.  
All replaced parts, products, and Connected Equipment and products and Connected Equipment on which a refund is made, become the property of RadioShack. New or reconditioned parts and products may be used in  
the performance of warranty service. Repaired or replaced parts in surge protectors and replacement surge protectors are warranted for the remainder of the Warranty Period. You will be charged for repair or replacement  
of the product made after the expiration of the Warranty Period.  
This Limited Warranty and Connected Equipment Guarantee does not cover: (a) damage or failure caused by or attributable to acts of God, abuse, accident, misuse, improper or abnormal usage, failure to follow instruc-  
tions, improper installation or maintenance, alteration, lightning; (b) any repairs other than: (i) surge protector repairs provided by a RadioShack Authorized Service Facility; and (ii) reimbursement of the cost of initial  
repairs to Connected Equipment performed by a service center authorized by the manufacturer of the Connected Equipment; (c) consumables such as fuses or batteries; (d) cosmetic damage; (e) transportation, shipping  
or insurance costs; or (f) costs of product or Connected Equipment removal, installation, set-up service adjustment or reinstallation.  
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
RadioShack Customer Relations, 200 Taylor Street, Sixth Floor, Fort Worth, Texas 76102  
04/02  
61-2422  
RadioShack Corporation  
Fort Worth, Texas 76102  
04A02  
Printed in China  
Download from Www.Somanuals.com. All Manuals Search And Download.  

RCA Cordless Telephone 2 9925 User Guide
Remington Blower RM180B User Guide
Roberts Radio Radio RD 1 User Guide
Roland Drums HD 3 User Guide
Ryobi Cultivator RY60512 User Guide
Samsung Printer Accessories mlt d205 User Guide
Samsung Tablet SGH I497ZSAATT User Guide
Sanyo Yard Vacuum C3632 User Guide
Sears Home Gym 31280781 User Guide
Sennheiser Headphones GP 03 M User Guide