Q Logic Switch 59047 09 C User Guide

SANbox  
Simple Network Management Protocol  
Reference Guide  
Firmware Version 7.4/7.8/7.10  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Configuring a Switch Using Enterprise Fabric Suite 2007 . . . . . . . . . . . . . .  
3-6  
59047-09 C  
Page iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Page iv  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
59047-09 C  
Page v  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Page vi  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
59047-09 C  
Page vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Page viii  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
59047-09 C  
Page ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Page x  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
59047-09 C  
Page xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
connUnitPortStatCountNumberOfflineSequences (1.3.6.1.3.94.4.5.1.38)  
5-79  
connUnitPortStatCountPrimitiveSequenceProtocolErrors  
(1.3.6.1.3.94.4.5.1.42) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-81  
Page xii  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
59047-09 C  
Page xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Page xiv  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
59047-09 C  
Page xv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Page xvi  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
List of Figures  
Figure  
Page  
List of Tables  
Table  
Page  
59047-09 C  
Page xvii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Page xviii  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Introduction  
This guide describes the support for Simple Network Management Protocol  
(SNMP) used with SANbox switch products. This Simple Network Management  
Protocol Reference Guide describes how to use SNMP to manage and monitor  
the SANbox switch products.  
This guide is organized as follows:  
Section 2 provides an overview of SNMP objectives, managers and agents,  
traps, Management Information Bases (MIB), and User Datagram Protocol.  
Section 3 describes how to configure a SANbox switch using Telnet and the  
Enterprise Fabric Suite 2007 graphical user interface.  
Section 4 describes the Management Information Bases (MIB-II).  
Section 5 describes the Fibre Alliance - Management Information Bases  
(FA-MIB version 4.0).  
Section 6 describes the Fabric Element - Management Information Bases  
(FE-MIB).  
Section 7 describes the QLOGIC Management Information Bases  
(QLOGIC-MIB).  
Section 8 describes the Firmware Download Management Information  
Bases (FD-MIB).  
Intended Audience  
This guide is intended for users responsible for the support of SNMP and SANbox  
switch configurations.  
59047-09 C  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1 – Introduction  
Related Materials  
S
Related Materials  
Refer to the following publications for switch hardware and installation  
information:  
SANbox 5600 Series Enterprise Fabric Suite 2007 User Guide, publication  
number 59097-06.  
SANbox 5802V Enterprise Fabric Suite 2007 User Guide, publication  
number 59266-00 A.  
SANbox 5802V Fibre Channel Switch Installation Guide, publication number  
59265-01.  
SANbox 5600 Series Fibre Channel Switch Installation Guide, publication  
number 59096-06.  
SANbox 5802V Fibre Channel Switch Command Line Interface Guide,  
publication number 59263-01.  
SANbox 5600 Series Fibre Channel Switch Command Line Interface Guide,  
publication number 59183-03.  
Technical Support  
Customers should contact their authorized maintenance provider for technical  
support of their QLogic switch products. QLogic-direct customers may contact  
QLogic Technical Support; others will be redirected to their authorized  
maintenance provider.  
Visit the QLogic switch support Web site listed in “Contact Information” on  
page 1-3 for the latest firmware and software updates.  
Availability  
QLogic Technical Support is available from 7:00 AM to 7:00 PM Central Standard  
Time, Monday through Friday, excluding QLogic-observed holidays.  
Training  
QLogic offers certification training for the technical professional for both the  
SANblade HBAs and the SANbox switches. From the training link at  
www.qlogic.com, you may choose Electronic-Based Training or schedule an  
intensive "hands-on" Certification course.  
1-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
1 – Introduction  
Technical Support  
A
Contact Information  
Please feel free to contact your QLogic approved reseller or QLogic Technical  
Support at any phase of integration for assistance. QLogic Technical Support can  
be reached by the following methods:  
Web  
North America Contact Information  
Email  
(952) 932-4040  
Phone  
Support contact information for other regions of the world is available at the  
The QLogic knowledge database contains troubleshooting information for the  
QLogic HBAs. Access the data base from the QLogic web site, www.qlogic.com.  
Click the Support tab, Use the search engine at the top of the page to look for  
specific troubleshooting information.  
59047-09 C  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1 – Introduction  
Technical Support  
S
Notes  
1-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 SNMP Overview  
Simple Network Management Protocol is the protocol governing network  
management and monitoring of network devices. This Simple Network  
Management Protocol Reference Guide describes how to use SNMP to manage  
and monitor the SANbox switch products. Specifically, this guide describes the  
SNMP agent that resides on the switch.  
The following topics are covered in this section:  
SNMP interface objectives  
Manager and agent  
Traps  
Management information bases (MIBs)  
User datagram protocol (UDP)  
Numbering system conventions  
SNMP Interface Objectives  
The objectives of the SNMP Interface are as follows:  
Connect to the SNMP agent that resides on the switch using a management  
workstation.  
Support of Fabric Element Management Information Bases (FE-MIB)  
(rfc2837) and Fibre Alliance Management Information Bases (FA-MIB) draft.  
Support of version 1 and 2 traps.  
The SNMP agent supports SNMPv1and SNMPv2c.  
Manager and Agent  
The two primary elements of SNMP are:  
Manager — the application that runs on the management workstation.  
Agent — the daemon application that runs on the switch.  
59047-09 C  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
2 – SNMP Overview  
Traps  
S
The Manager is the application through which the network administrator performs  
network management functions. The SNMP agent is the direct interface on the  
switch for any SNMP manager connecting to the switch using the SNMP protocol,  
as shown in Figure 2-1. The agent will be started by the script file(s) responsible  
for switch initialization when the switch powers up or when the switch is reset.  
When an SNMP request arrives at the agent, the agent will compose a message  
and pass it on to Switch Management to process the message and provide a  
response to the agent. The agent then provides a response to the originator of the  
SNMP request. The SNMP agent does not have direct access to the internal  
database of the switch.  
Workstation with SNMP  
Manager Application  
Ethernet Connection  
Switch with Agent and  
Common User Interface API  
Figure 2-1 SNMP Interface Architecture  
Traps  
Traps are notification messages sent from the switch to a registered manager  
when a change of state occurs within the switch. A change of state can be an  
alarm condition or simply a configuration change.  
The Fibre Alliance MIB defines a trap table configurable through SNMP. A trap  
table may have up to 5 entries, and can be configured using the SNMP Manager  
or Enterprise Fabric Suite 2007 graphical user interface. The same trap table  
information is available to both SNMP Manager and Enterprise Fabric Suite 2007.  
A trap event is reported when the incoming error has a severity level less than or  
equal to the configured severity level. The trap event types and trap severity levels  
are listed in Table 2-1. Refer to Table 5-1 for information on specific traps.  
2-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2 – SNMP Overview  
Management Information Base  
A
Table 2-1. Trap Severity Levels  
Event Type Severity Level  
Unknown  
Emergency  
Alert  
1
2
3
Critical  
Error  
4
5
Warning  
Notify  
6
7
Info  
8
Debug  
Mark  
9
10  
Management Information Base  
Management information bases (MIBs) define the properties of the managed  
object within the device to be managed. Every managed device keeps a database  
of values for each definition written in the MIB. It is not the actual database itself; it  
is implementation dependant. Definition of the MIB conforms to the Structure of  
Management Information (SMI) given in Request For Comment (RFC) 1155. The  
latest Internet MIB is given in RFC 1213, and is sometimes called MIB-II.  
User Datagram Protocol  
SANbox switches support the following User Datagram Protocol (UDP) settings:  
Agents “listen” on UDP port 161.  
Responses are sent back to the originating Network Management Station  
(NMS) port from a dynamic port, although many agents use port 161 also for  
this target.  
The maximum SNMP message size is 65507 octets (maximum UDP  
message size).  
The minimum receive packet size for SNMP implementations is 484 octets  
in length.  
Agent and Network Monitoring Systems are responsible for determining  
error recovery.  
59047-09 C  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                       
2 – SNMP Overview  
Numbering System Conventions  
S
Numbering System Conventions  
The conventions for numbering systems in this guide are as follows:  
Decimal = 101  
Hexadecimal = 0x101  
Binary = 101b  
2-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 Configuring a Switch  
This section describes how to configure a SANbox switch to support SNMP. The  
following topics are covered:  
System specifications and requirements  
Configuring a switch using the Telnet command line interface  
Configuring a switch using the Enterprise Fabric Suite 2007 application  
System Specifications and Requirements  
SANbox switches support SNMPv1 and SNMPv2c.  
Version 1 and 2 traps are supported.  
Hardware — one out-of-band Ethernet connection is required.  
Software — one switch management software application allows you to:  
Monitor and control the switch.  
Read, write, and receive trap information, if supported.  
Ports on the switch reserved for SNMP:  
Port 161 is not configurable, and is used for the standard SNMP  
commands.  
Port 162 is configurable and is the default port used for traps.  
One or more in-band switches can be managed by an out-of-band SANbox  
switch acting as a proxy switch.  
SANbox can only act as a proxy for other SANbox switches.  
SANbox proxy capability can be disabled.  
59047-09 C  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3 – Configuring a Switch  
Configuring a Switch Using the Command Line Interface  
S
Configuring a Switch Using the Command Line  
Interface  
The Telnet command line interface offers a convenient way to change SNMP  
parameters. SNMP parameter defaults are preset during manufacturing. For  
security purposes, these default values should be changed. For specific  
information about SNMP parameters, refer to the SNMP Configuration section in  
the corresponding SANbox Switch Management User Guide. To configure a  
switch using the command line interface, do the following.  
3-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 – Configuring a Switch  
Configuring a Switch Using the Command Line Interface  
A
Press the Enter key to accept the default value for each parameter.  
SB5600.116.50 (admin) #> set setup snmp  
A list of attributes with formatting and current values will follow.  
Enter a new value or simply press the ENTER key to accept the current value.  
If you wish to terminate this process before reaching the end of the attributes  
for the category being processed, press 'q' or 'Q' and the ENTER key to do so.  
If you wish to terminate the configuration process completely, press 'qq' or  
'QQ' and the ENTER key to do so.  
SNMP System Configuration - may optionally use 'set setup snmp common'  
command.  
Current Values:  
SnmpEnabled  
Contact  
True  
<sysContact undefined>  
<sysLocation undefined>  
public  
Location  
ReadCommunity  
WriteCommunity  
private  
AuthFailureTrap False  
ProxyEnabled  
SNMPv3Enabled  
True  
False  
New Value (press ENTER to not specify value, 'q' to quit):  
SnmpEnabled  
Contact  
(True / False)  
:
(string, max=64 chars) :  
(string, max=64 chars) :  
(string, max=32 chars) :  
(string, max=32 chars) :  
Location  
ReadCommunity  
WriteCommunity  
AuthFailureTrap (True / False)  
:
:
:
ProxyEnabled  
SNMPv3Enabled  
(True / False)  
(True / False)  
SNMP Trap 1 Configuration - may optionally use 'set setup snmp trap 1'  
command.  
Current Values:  
Trap1Enabled  
Trap1Address  
Trap1Port  
False  
10.0.0.254  
5001  
Trap1Severity  
Trap1Version  
info  
2
Trap1Community public  
New Value (press ENTER to not specify value, 'q' to quit):  
Trap1Enabled  
Trap1Address  
Trap1Port  
(True / False)  
:
(hostname, IPv4, or IPv6 Address) :  
(decimal value, 1-65535)  
(select a severity level)  
:
Trap1Severity  
1=unknown  
6=warning  
59047-09 C  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 – Configuring a Switch  
Configuring a Switch Using the Command Line Interface  
S
2=emergency  
3=alert  
7=notify  
8=info  
4=critical  
5=error  
9=debug  
10=mark  
:
Trap1Version  
(1 / 2)  
:
:
Trap1Community (string, max=32 chars)  
SNMP Trap 2 Configuration - may optionally use 'set setup snmp trap 2'  
command.  
Current Values:  
Trap2Enabled  
Trap2Address  
Trap2Port  
False  
10.20.43.231  
162  
info  
2
Trap2Severity  
Trap2Version  
Trap2Community public  
New Value (press ENTER to not specify value, 'q' to quit):  
Trap2Enabled  
Trap2Address  
Trap2Port  
(True / False)  
:
(hostname, IPv4, or IPv6 Address) :  
(decimal value, 1-65535)  
(select a severity level)  
:
Trap2Severity  
1=unknown  
2=emergency  
3=alert  
6=warning  
7=notify  
8=info  
4=critical  
5=error  
9=debug  
10=mark  
:
Trap2Version  
(1 / 2)  
:
:
Trap2Community (string, max=32 chars)  
SNMP Trap 3 Configuration - may optionally use 'set setup snmp trap 3'  
command.  
Current Values:  
Trap3Enabled  
Trap3Address  
Trap3Port  
False  
10.20.33.231  
162  
Trap3Severity  
Trap3Version  
warning  
2
Trap3Community public  
New Value (press ENTER to not specify value, 'q' to quit):  
Trap3Enabled  
Trap3Address  
Trap3Port  
(True / False)  
:
(hostname, IPv4, or IPv6 Address) :  
(decimal value, 1-65535)  
(select a severity level)  
:
Trap3Severity  
1=unknown  
6=warning  
7=notify  
2=emergency  
3-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 – Configuring a Switch  
Configuring a Switch Using the Command Line Interface  
A
3=alert  
8=info  
4=critical  
5=error  
9=debug  
10=mark  
:
Trap3Version  
(1 / 2)  
:
:
Trap3Community (string, max=32 chars)  
SNMP Trap 4 Configuration - may optionally use 'set setup snmp trap 4'  
command.  
Current Values:  
Trap4Enabled  
Trap4Address  
Trap4Port  
False  
0.0.0.0  
162  
Trap4Severity  
Trap4Version  
warning  
2
Trap4Community public  
New Value (press ENTER to not specify value, 'q' to quit):  
Trap4Enabled  
Trap4Address  
Trap4Port  
(True / False)  
:
(hostname, IPv4, or IPv6 Address) :  
(decimal value, 1-65535)  
(select a severity level)  
:
Trap4Severity  
1=unknown  
2=emergency  
3=alert  
6=warning  
7=notify  
8=info  
4=critical  
5=error  
9=debug  
10=mark  
:
Trap4Version  
(1 / 2)  
:
:
Trap4Community (string, max=32 chars)  
SNMP Trap 5 Configuration - may optionally use 'set setup snmp trap 5'  
command.  
Current Values:  
Trap5Enabled  
Trap5Address  
Trap5Port  
False  
0.0.0.0  
162  
Trap5Severity  
Trap5Version  
warning  
2
Trap5Community public  
New Value (press ENTER to not specify value, 'q' to quit):  
Trap5Enabled  
Trap5Address  
Trap5Port  
(True / False)  
:
(hostname, IPv4, or IPv6 Address) :  
(decimal value, 1-65535)  
(select a severity level)  
:
Trap5Severity  
1=unknown  
2=emergency  
3=alert  
6=warning  
7=notify  
8=info  
59047-09 C  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 – Configuring a Switch  
Configuring a Switch Using Enterprise Fabric Suite 2007  
S
4=critical  
5=error  
9=debug  
10=mark  
:
Trap5Version  
(1 / 2)  
:
:
Trap5Community (string, max=32 chars)  
Do you want to save and activate this snmp setup? (y/n): [n]  
SNMP setup NEITHER saved NOR activated.  
SB5600.116.50 (admin) #>  
Configuring a Switch Using Enterprise Fabric  
Suite 2007  
To configure a SANbox switch using Enterprise Fabric Suite 2007, use the SNMP  
Properties, Switch Properties, and Network Properties dialogs. For specific  
information, refer to the corresponding Switch Management User’s Guide.  
3-6  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
4 MIB-II Objects  
This section covers the implementation details for the MIB-II on the SANbox  
switch. A MIB defines the properties of the managed object within the device to be  
managed. Every managed device keeps a database of values for each definition  
written in the MIB. It is not the actual database itself; it is implementation  
dependant. Definition of the MIB conforms to the SMI given in RFC 1155. The  
latest Internet MIB is given in RFC 1213, and is sometimes called MIB-II.  
Groups in MIB-II  
Refer the Table 4-1 for the syntax for MIB-II Groups.  
Table 4-1. MIB-II Groups  
Group  
Syntax  
system  
OBJECT IDENTIFIER ::= { mib-2 1 }  
OBJECT IDENTIFIER ::= { mib-2 2 }  
OBJECT IDENTIFIER ::= { mib-2 3 }  
OBJECT IDENTIFIER ::= { mib-2 4 }  
OBJECT IDENTIFIER ::= { mib-2 5 }  
OBJECT IDENTIFIER ::= { mib-2 6 }  
OBJECT IDENTIFIER ::= { mib-2 7 }  
OBJECT IDENTIFIER ::= { mib-2 11 }  
interfaces  
at  
ip  
icmp  
tcp  
udp  
snmp  
System Group  
Implementation of the System group is mandatory for all systems. If an agent is  
not configured to have a value for any of these variables, a string of length 0 is  
returned.  
59047-09 C  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
4 – MIB-II Objects  
System Group  
S
sysDescr (1.3.6.1.2.1.1.1)  
A textual description of the entity. This value should include the full name and  
version identification of the system's hardware type, operating-system, and  
networking software. It is mandatory that this only contain printable American  
Standard Code for Information Interchange (ASCII) characters.  
Syntax  
DisplayString (SIZE (0..255))  
Access  
read-only  
Status  
Mandatory  
Return Value  
The default values are: SANbox 5200 = SANbox 5200 FC Switch, SANbox  
5202 = SANbox 5202 FC Switch, SANbox 5600 = SANbox 5600 FC Switch,  
SANbox 5602 = SANbox 5602 FC Switch  
sysObjectID (1.3.6.1.2.1.1.2)  
The vendor's authoritative identification of the network management subsystem  
contained in the entity. This value is allocated within the SMI enterprise subtree  
(1.3.6.1.4.1) and provides an easy and unambiguous means for determining  
`what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was  
assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier  
1.3.6.1.4.1.4242.1.1 to its `Fred Router'.  
Syntax  
OBJECT IDENTIFIER  
Access  
read-only  
Status  
mandatory  
Return Value  
The values are: SANbox 5200 = 1.3.6.1.4.1.1663.1.1.1.1.17, SANbox 5202  
= 1.3.6.1.4.1.1663.1.1.1.1.30, SANbox 5600 = 1.3.6.1.4.1.1663.1.1.1.1.23,  
and SANbox 5602 = 1.3.6.1.4.1.1663.1.1.1.1.24  
4-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4 – MIB-II Objects  
System Group  
A
sysUpTime (1.3.6.1.2.1.1.3)  
The time, in hundredths of a second, since the network management portion of  
the system was last re-initialized.  
Syntax  
TimeTicks  
Access  
read-only  
Status  
mandatory  
Return Value  
The time since the switch was powered on, or last reset (reset, hardreset, or  
hotreset) was executed. For example, 3 days 21 hours, 5 minutes, and  
26.84 seconds. The value will roll over after approximately 497 days of  
continuous up time.  
sysContact (1.3.6.1.2.1.1.4)  
The textual identification of the contact person for this managed Node, together  
with information on how to contact this person.  
Syntax  
DisplayString (SIZE (0..255))  
Access  
read-write  
Status  
mandatory  
Return Value  
The default is: <sysContact undefined>. The string size is limited to a  
maximum of 64.  
sysName (1.3.6.1.2.1.1.5)  
An administratively-assigned name for this managed Node. By convention, this is  
the Node's fully-qualified domain name.  
Syntax  
DisplayString (SIZE (0..255))  
59047-09 C  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
System Group  
S
Access  
read-write  
Status  
mandatory  
Return Value  
The defaults are: SANbox 5200 Series = SANbox, SANbox 5600 Series =  
SANbox  
sysLocation (1.3.6.1.2.1.1.6)  
The physical location of this Node, such as telephone closet and 3rd floor.  
Syntax  
DisplayString (SIZE (0..255))  
Access  
read-write  
Status  
mandatory  
Return Value  
The default is: <sysLocation undefined>. The string size is limited to a  
maximum of 64.  
sysServices (1.3.6.1.2.1.1.7)  
A value that indicates the set of services that this entity primarily offers.The value  
is a sum. This sum initially takes the value zero. Then, for each layer L in the  
range 1 through 7 that this Node performs transactions for, 2 raised to (L - 1) is  
added to the sum. For example, a Node that performs primarily routing functions  
would have a value of 4 (2^(3-1)). In contrast, a Node that is a host offering  
application services would have a value of 72 (2^(4-1) + 2^(7-1)).  
Syntax  
INTEGER (0..127)  
Access  
read-only  
Status  
mandatory  
4-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4 – MIB-II Objects  
The Interfaces Group  
A
Return Value  
The default is: 2  
The Interfaces Group  
Implementation of the Interfaces group is mandatory for all systems.  
ifNumber (1.3.6.1.2.1.2.1)  
The number of network interfaces (regardless of their current state) present on  
this system.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The default is: 2  
The Interfaces Table  
The Interfaces table contains information on the entity's interfaces. Each interface  
is thought of as being attached to a `subnetwork'. This term should not be  
confused with `subnet' which refers to an addressing partitioning scheme used in  
the Internet suite of protocols.  
ifIndex (1.3.6.1.2.1.2.2.1.1)  
A unique value for each interface. Its value ranges between 1 and the value of  
ifNumber. The value for each interface must remain constant at least from one  
re-initialization of the entity's network management system to the next  
re-initialization.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The Interfaces Table  
S
ifDescr (1.3.6.1.2.1.2.2.1.2)  
A textual string containing information about the interface. This string should  
include the name of the manufacturer, the product name, and the version of the  
hardware interface.  
Syntax  
DisplayString (SIZE (0..255))  
Access  
read-only  
Status  
mandatory  
ifType (1.3.6.1.2.1.2.2.1.3)  
The type of interface distinguished according to the physical/link protocol(s)  
immediately `below' the network layer in the protocol stack.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
ifMtu (1.3.6.1.2.1.2.2.1.4)  
The size of the largest datagram which can be sent/received on the interface,  
specified in octets. For interfaces that are used for transmitting network  
datagrams, this is the size of the largest network datagram that can be sent on the  
interface.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
4-6  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The Interfaces Table  
A
ifSpeed (1.3.6.1.2.1.2.2.1.5)  
An estimate of the interface's current bandwidth in bits per second. For interfaces  
that do not vary in bandwidth or for those where no accurate estimation can be  
made, this object should contain the nominal bandwidth.  
Syntax  
Gauge  
Access  
read-only  
Status  
mandatory  
ifPhysAddress (1.3.6.1.2.1.2.2.1.6)  
The interface's address at the protocol layer immediately “below” the network  
layer in the protocol stack. For interfaces that do not have such an address, such  
as a serial line, this object should contain an octet string of zero length.  
Syntax  
PhysAddress  
Access  
read-only  
Status  
mandatory  
ifAdminStatus (1.3.6.1.2.1.2.2.1.7)  
The desired state of the interface. The testing(3) state indicates that no  
operational packets can be passed.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
59047-09 C  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The Interfaces Table  
S
ifOperStatus (1.3.6.1.2.1.2.2.1.8)  
The current operational state of the interface. The testing(3) state indicates that  
no operational packets can be passed.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
ifLastChange (1.3.6.1.2.1.2.2.1.9)  
The value of sysUpTime at the time the interface entered its current operational  
state. If the current state was entered prior to the last re-initialization of the local  
network management subsystem, then this object contains a zero value.  
Syntax  
TimeTicks  
Access  
read-only  
Status  
mandatory  
ifInOctets (1.3.6.1.2.1.2.2.1.10)  
The total number of octets received on the interface, including framing characters.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifInUcastPkts (1.3.6.1.2.1.2.2.1.11)  
The number of subnetwork-unicast packets delivered to a higher-layer protocol.  
4-8  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The Interfaces Table  
A
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifInNUcastPkts (1.3.6.1.2.1.2.2.1.12)  
The number of non-unicast (that is, subnetwork- broadcast or  
subnetwork-multicast) packets delivered to a higher-layer protocol.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifInDiscards (1.3.6.1.2.1.2.2.1.13)  
The number of inbound packets that were chosen to be discarded even though no  
errors had been detected to prevent their being deliverable to a higher-layer  
protocol. One possible reason for discarding such a packet could be to free up  
buffer space.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifInErrors (1.3.6.1.2.1.2.2.1.14)  
The number of inbound packets that contained errors preventing them from being  
deliverable to a higher-layer protocol.  
Syntax  
Counter  
59047-09 C  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The Interfaces Table  
S
Access  
read-only  
Status  
mandatory  
ifInUnknownProtos (1.3.6.1.2.1.2.2.1.15)  
The number of packets received from the interface that were discarded because  
of an unknown or unsupported protocol.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifOutOctets (1.3.6.1.2.1.2.2.1.16)  
The total number of octets transmitted out of the interface, including framing  
characters.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifOutUcastPkts (1.3.6.1.2.1.2.2.1.17)  
The total number of packets that higher level protocols requested be transmitted  
to a subnetwork unicast address, including those that were discarded or not sent.  
Syntax  
Counter  
Access  
read-only  
4-10  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The Interfaces Table  
A
Status  
mandatory  
ifOutNUcastPkts (1.3.6.1.2.1.2.2.1.18)  
The total number of packets that higher level protocols requested be transmitted  
to a non-unicast (subnetwork broadcast or subnetwork multicast) address,  
including those that were discarded or not sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifOutDiscards (1.3.6.1.2.1.2.2.1.19)  
The number of outbound packets that were chosen to be discarded even though  
no errors had been detected to prevent their being transmitted. One possible  
reason for discarding such a packet could be to free up buffer space.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ifOutErrors (1.3.6.1.2.1.2.2.1.20)  
The number of outbound packets that could not be transmitted because of errors.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The Address Translation Group  
S
ifOutQLen (1.3.6.1.2.1.2.2.1.21)  
The length (in packets) of the output packet queue.  
Syntax  
Gauge  
Access  
read-only  
Status  
mandatory  
ifSpecific (1.3.6.1.2.1.2.2.1.22)  
A reference to MIB definitions specific to the particular media being used to realize  
the interface. For example, if the interface is realized by an Ethernet, then the  
value of this object refers to a document that defines objects specific to Ethernet.  
If this information is not present, its value should be set to the OBJECT  
IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any  
conformant implementation of ASN.1 (Abstract Syntax Notation) and BER must  
be able to generate and recognize this value.  
Syntax  
OBJECT IDENTIFIER  
Access  
read-only  
Status  
mandatory  
The Address Translation Group  
Implementation of the Address Translation group is mandatory for all systems.  
However, this group is deprecated by MIB-II. That is, it is being included solely for  
compatibility with MIB-I Nodes, and will most likely be excluded from MIB-III  
Nodes. From MIB-II and onwards, each network protocol group contains its own  
address translation tables.  
The Address Translation group contains one table which is the union across all  
interfaces of the translation tables for converting a NetworkAddress (for example,  
an IP address) into a subnetwork-specific address. For lack of a better term, this  
document refers to such a subnetwork-specific address as a `physical' address.  
4-12  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The Address Translation Group  
A
Examples of such translation tables are for: broadcast media where ARP is in use,  
the translation table is equivalent to the ARP cache, or on an X.25 network where  
non-algorithmic translation to X.121 addresses is required. The translation table  
contains the NetworkAddress to X.121 address equivalences.  
atIfIndex (1.3.6.1.2.1.3.1.1.1)  
The interface on which this entry's equivalence is effective. The interface  
identified by a particular value of this index is the same interface as identified by  
the same value of ifIndex.  
Syntax  
INTEGER  
Access  
read-write  
Status  
deprecated  
atPhysAddress (1.3.6.1.2.1.3.1.1.2)  
The media-dependent “physical” address. Setting this object to a null string (one  
of zero length) has the effect of invalidating the corresponding entry in the atTable  
object. That is, it effectively disassociates the interface identified with the entry  
from the mapping identified with the entry. It is an implementation-specific matter  
as to whether the agent removes an invalidated entry from the table. Accordingly,  
management workstations must be prepared to receive tabular information from  
agents that corresponds to entries not currently in use. Proper interpretation of  
such entries requires examination of the relevant atPhysAddress object.  
Syntax  
PhysAddress  
Access  
read-write  
Status  
deprecated  
atNetAddress (1.3.6.1.2.1.3.1.1.3)  
The NetworkAddress corresponding to the media-dependent `physical' address.  
Syntax  
NetworkAddress  
59047-09 C  
4-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Group  
S
Access  
read-write  
Status  
deprecated  
The IP Group  
Implementation of the IP group is mandatory for all systems.  
ipForwarding (1.3.6.1.2.1.4.1)  
The indication of whether this entity is acting as an IP Gateway with respect to the  
forwarding of datagrams received by, but not addressed to, this entity. IP  
Gateways forward datagrams; IP hosts do not (except those source-routed from  
the host).  
For some managed Nodes, this object may take on only a subset of the values  
possible. Accordingly, it is appropriate for an agent to return a “badValue”  
response if a management station attempts to change this object to an  
inappropriate value.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Returns forwarding (1). Writes not supported.  
ipDefaultTTL (1.3.6.1.2.1.4.2)  
The default value inserted into the Time-To-Live field of the IP header of  
datagrams originated at this entity whenever a TTL value is not supplied by the  
transport layer protocol.  
Syntax  
INTEGER  
Access  
read-write  
4-14  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Group  
A
Status  
mandatory  
Return Value  
Returns 64 (0x40). Writes not supported.  
ipInReceives (1.3.6.1.2.1.4.3)  
The total number of input datagrams received from interfaces, including those  
received in error.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipInHdrErrors (1.3.6.1.2.1.4.4)  
The number of input datagrams discarded due to errors in their IP headers. These  
include bad checksums, version number mismatch, other format errors,  
time-to-live exceeded, and errors discovered in processing their IP options.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipInAddrErrors (1.3.6.1.2.1.4.5)  
The number of input datagrams discarded because the IP address in their IP  
header's destination field was not a valid address to be received at this entity. This  
count includes invalid addresses (for example, 0.0.0.0) and addresses of  
unsupported Classes (for example, Class E). For entities which are not IP  
Gateways and therefore do not forward datagrams, this counter includes  
datagrams discarded because the destination address was not a local address.  
Syntax  
Counter  
59047-09 C  
4-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Group  
S
Access  
read-only  
Status  
mandatory  
ipForwDatagrams (1.3.6.1.2.1.4.6)  
The number of input datagrams for which this entity was not their final IP  
destination. As a result, an attempt was made to find a route to forward them to  
that final destination. In entities that do not act as IP Gateways, this counter will  
include only those packets that were Source Routed from this entity, and the  
Source Route option processing was successful.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipInUnknownProtos (1.3.6.1.2.1.4.7)  
The number of locally-addressed datagrams received successfully but discarded  
because of an unknown or unsupported protocol.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipInDiscards (1.3.6.1.2.1.4.8)  
The number of input IP datagrams for which no problems were encountered to  
prevent their continued processing, but which were discarded (for example, for  
lack of buffer space). This counter does not include any datagrams discarded  
while awaiting reassembly.  
Syntax  
Counter  
4-16  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Group  
A
Access  
read-only  
Status  
mandatory  
ipInDelivers (1.3.6.1.2.1.4.9)  
The total number of input datagrams successfully delivered to IP user protocols  
(including ICMP).  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipOutRequests (1.3.6.1.2.1.4.10)  
The total number of IP datagrams that local IP user protocols (including ICMP)  
supplied to IP in requests for transmission. This counter does not include any  
datagrams counted in ipForwDatagrams.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipOutDiscards (1.3.6.1.2.1.4.11)  
The number of output IP datagrams for which no problem was encountered to  
prevent their transmission to their destination, but which were discarded (for  
example, for lack of buffer space). This counter would include datagrams counted  
in ipForwDatagrams if any such packets met this (discretionary) discard criterion.  
Syntax  
Counter  
59047-09 C  
4-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Group  
S
Access  
read-only  
Status  
mandatory  
ipOutNoRoutes (1.3.6.1.2.1.4.12)  
The number of IP datagrams discarded because no route could be found to  
transmit them to their destination. This counter includes any packets counted in  
ipForwDatagrams which meet this “no-route” criterion. This includes any  
datagrams that a host cannot route because all of its default gateways are down.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipReasmTimeout (1.3.6.1.2.1.4.13)  
The maximum number of seconds which received fragments are held while they  
are awaiting reassembly at this entity.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
ipReasmReqds (1.3.6.1.2.1.4.14)  
The number of IP fragments received that needed to be reassembled at this entity.  
Syntax  
Counter  
Access  
read-only  
4-18  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Group  
A
Status  
mandatory  
ipReasmOKs (1.3.6.1.2.1.4.15)  
The number of IP datagrams successfully reassembled.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipReasmFails (1.3.6.1.2.1.4.16)  
The number of failures detected by the IP reassembly algorithm for example,  
timed out, errors). This is not necessarily a count of discarded IP fragments, since  
some algorithms (notably the algorithm in RFC 815) can lose track of the number  
of fragments by combining them as they are received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipFragOKs (1.3.6.1.2.1.4.17)  
The number of IP datagrams that have been successfully fragmented at this  
entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Address Table  
S
ipFragFails (1.3.6.1.2.1.4.18)  
The number of IP datagrams that have been discarded because they needed to  
be fragmented at this entity, but could not because their Don't Fragment flag was  
set.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
ipFragCreates (1.3.6.1.2.1.4.19)  
The number of IP datagram fragments that have been generated as a result of  
fragmentation at this entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
The IP Address Table  
The IP address table contains this entity's IP addressing information.  
ipAdEntAddr (1.3.6.1.2.1.4.20.1.1)  
The IP address to which this entry's addressing information pertains.  
Syntax  
IpAddress  
Access  
read-only  
Status  
mandatory  
4-20  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The IP Address Table  
A
ipAdEntIfIndex (1.3.6.1.2.1.4.20.1.2)  
The index value which uniquely identifies the interface to which this entry is  
applicable. The interface identified by a particular value of this index is the same  
interface as identified by the same value of ifIndex.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
ipAdEntNetMask (1.3.6.1.2.1.4.20.1.3)  
The subnet mask associated with the IP address of this entry. The value of the  
mask is an IP address with all the network bits set to 1 and all the hosts bits set to  
0.  
Syntax  
IpAddress  
Access  
read-only  
Status  
mandatory  
ipAdEntBcastAddr (1.3.6.1.2.1.4.20.1.4)  
The value of the least-significant bit in the IP broadcast address used for sending  
datagrams on the (logical) interface associated with the IP address of this entry.  
For example, when the Internet standard all-ones broadcast address is used, the  
value will be 1. This value applies to both the subnet and network broadcasts  
addresses used by the entity on this (logical) interface.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Routing Table  
S
ipAdEntReasmMaxSize (1.3.6.1.2.1.4.20.1.5)  
The size of the largest IP datagram which this entity can reassemble from  
incoming IP fragmented datagrams received on this interface.  
Syntax  
INTEGER (0..65535)  
Access  
read-only  
Status  
mandatory  
The IP Routing Table  
The IP routing table contains an entry for each route presently known to this entity.  
ipRouteDest (1.3.6.1.2.1.4.21.1.1)  
The destination IP address of this route. An entry with a value of 0.0.0.0 is  
considered a default route. Multiple routes to a single destination can appear in  
the table, but access to such multiple entries is dependent on the table-access  
mechanisms defined by the network management protocol in use.  
Syntax  
IpAddress  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteIfIndex (1.3.6.1.2.1.4.21.1.2)  
The index value which uniquely identifies the local interface through which the  
next hop of this route should be reached. The interface identified by a particular  
value of this index is the same interface as identified by the same value of ifIndex.  
Syntax  
INTEGER  
4-22  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The IP Routing Table  
A
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteMetric1 (1.3.6.1.2.1.4.21.1.3)  
The primary routing metric for this route. The semantics of this metric are  
determined by the routing protocol specified in the route's ipRouteProto value. If  
this metric is not used, its value should be set to -1.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteMetric2 (1.3.6.1.2.1.4.21.1.4)  
An alternate routing metric for this route. The semantics of this metric are  
determined by the routing protocol specified in the route's ipRouteProto value. If  
this metric is not used, its value should be set to -1.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
59047-09 C  
4-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4 – MIB-II Objects  
The IP Routing Table  
S
ipRouteMetric3 (1.3.6.1.2.1.4.21.1.5)  
An alternate routing metric for this route. The semantics of this metric are  
determined by the routing protocol specified in the route's ipRouteProto value. If  
this metric is not used, its value should be set to -1.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteMetric4 (1.3.6.1.2.1.4.21.1.6)  
An alternate routing metric for this route. The semantics of this metric are  
determined by the routing protocol specified in the route's ipRouteProto value. If  
this metric is not used, its value should be set to -1.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteNextHop (1.3.6.1.2.1.4.21.1.7)  
The IP address of the next hop of this route. In the case of a route bound to an  
interface which is realized from a broadcast media, the value of this field is the  
agent's IP address on that interface.  
Syntax  
IpAddress  
4-24  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Routing Table  
A
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteType (1.3.6.1.2.1.4.21.1.8)  
The type of route. The values direct(3) and indirect(4) refer to the notion of direct  
and indirect routing in the IP architecture. Setting this object to the value invalid(2)  
has the effect of invalidating the corresponding entry in the ipRouteTable object.  
That is, it effectively disassociates the destination identified with the entry from the  
route identified with the entry. It is an implementation-specific matter as to whether  
the agent removes an invalidated entry from the table. Accordingly, management  
stations must be prepared to receive tabular information from agents that  
corresponds to entries not currently in use. Proper interpretation of such entries  
requires examination of the relevant ipRouteType object.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteProto (1.3.6.1.2.1.4.21.1.9)  
The routing mechanism through which this route was learned. Inclusion of values  
for gateway routing protocols is not intended to imply that hosts should support  
those protocols.  
Syntax  
INTEGER  
Access  
read-only  
59047-09 C  
4-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4 – MIB-II Objects  
The IP Routing Table  
S
Status  
mandatory  
ipRouteAge (1.3.6.1.2.1.4.21.1.10)  
The number of seconds since this route was last updated or otherwise determined  
to be correct. No semantics of `too old' can be implied except through knowledge  
of the routing protocol by which the route was learned.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteMask (1.3.6.1.2.1.4.21.1.11)  
Indicate the mask to be logical-ANDed with the destination address before being  
compared to the value in the ipRouteDest field.  
Syntax  
IpAddress  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteMetric5 (1.3.6.1.2.1.4.21.1.12)  
An alternate routing metric for this route. The semantics of this metric are  
determined by the routing-protocol specified in the route's ipRouteProto value. If  
this metric is not used, its value should be set to -1.  
Syntax  
INTEGER  
4-26  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Address Translation Table  
A
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipRouteInfo (1.3.6.1.2.1.4.21.1.13)  
A reference to MIB definitions specific to the particular routing protocol which is  
responsible for this route, as determined by the value specified in the route's  
ipRouteProto value. If this information is not present, its value should be set to the  
OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier. Any  
conformant implementation of ASN.1 and BER must be able to generate and  
recognize this value.  
Syntax  
OBJECT IDENTIFIER  
Access  
read-only  
Status  
mandatory  
The IP Address Translation Table  
The IP address translation table contain the IpAddress to`physical' address  
equivalences. Some interfaces do not use translation tables for determining  
address equivalences (for example, DDN-X.25 has an algorithmic method). If all  
interfaces are of this type, then the Address Translation table is empty, that is, has  
zero entries.  
ipNetToMediaIfIndex (1.3.6.1.2.1.4.22.1.1)  
The interface on which this entry's equivalence is effective. The interface  
identified by a particular value of this index is the same interface as identified by  
the same value of ifIndex.  
Syntax  
INTEGER  
Access  
read-write  
59047-09 C  
4-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The IP Address Translation Table  
S
Status  
mandatory  
Return Value  
Writes not supported.  
ipNetToMediaPhysAddress (1.3.6.1.2.1.4.22.1.2)  
The media-dependent `physical' address.  
Syntax  
PhysAddress  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
ipNetToMediaNetAddress (1.3.6.1.2.1.4.22.1.3)  
The IpAddress corresponding to the media-dependent `physical' address.  
Syntax  
IpAddress  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
4-28  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4 – MIB-II Objects  
Additional IP Objects  
A
ipNetToMediaType (1.3.6.1.2.1.4.22.1.4)  
The type of mapping. Setting this object to the value invalid(2) has the effect of  
invalidating the corresponding entry in the ipNetToMediaTable. That is, it  
effectively disassociates the interface identified with the entry from the mapping  
identified with the entry. It is an implementation-specific matter as to whether the  
agent removes an invalidated entry from the table. Accordingly, management  
stations must be prepared to receive tabular information from agents that  
corresponds to entries not currently in use. Proper interpretation of such entries  
requires examination of the relevant ipNetToMediaType object.  
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
Additional IP Objects  
Following are the additional IP objects.  
ipRoutingDiscards (1.3.6.1.2.1.4.23)  
The number of routing entries which were chosen to be discarded even though  
they are valid. One possible reason for discarding such an entry could be to  
free-up buffer space for other routing entries.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The ICMP Group  
S
The ICMP Group  
Implementation of the ICMP group is mandatory for all systems.  
icmpInMsgs (1.3.6.1.2.1.5.1)  
The total number of ICMP messages received by the entity. This counter includes  
all those counted by icmpInErrors.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInErrors (1.3.6.1.2.1.5.2)  
The number of ICMP messages received by the entity but were determined as  
having ICMP-specific errors (such as, bad ICMP checksums, bad length).  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInDestUnreachs (1.3.6.1.2.1.5.3)  
The number of ICMP Destination Unreachable messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
4-30  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The ICMP Group  
A
icmpInTimeExcds (1.3.6.1.2.1.5.4)  
The number of ICMP Time Exceeded messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInParmProbs (1.3.6.1.2.1.5.5)  
The number of ICMP Parameter Problem messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInSrcQuenchs (1.3.6.1.2.1.5.6)  
The number of ICMP Source Quench messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInRedirects (1.3.6.1.2.1.5.7)  
The number of ICMP Redirect messages received.  
Syntax  
Counter  
59047-09 C  
4-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The ICMP Group  
S
Access  
read-only  
Status  
mandatory  
icmpInEchos (1.3.6.1.2.1.5.8)  
The number of ICMP Echo (request) messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInEchoReps (1.3.6.1.2.1.5.9)  
The number of ICMP Echo Reply messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInTimestamps (1.3.6.1.2.1.5.10)  
The number of ICMP Timestamp (request) messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
4-32  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The ICMP Group  
A
icmpInTimestampReps (1.3.6.1.2.1.5.11)  
The number of ICMP Timestamp Reply messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInAddrMasks (1.3.6.1.2.1.5.12)  
The number of ICMP Address Mask Request messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpInAddrMaskReps (1.3.6.1.2.1.5.13)  
The number of ICMP Address Mask Reply messages received.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutMsgs (1.3.6.1.2.1.5.14)  
The total number of ICMP messages which this entity attempted to send. This  
counter includes all those counted by icmpOutErrors.  
Syntax  
Counter  
59047-09 C  
4-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The ICMP Group  
S
Access  
read-only  
Status  
mandatory  
icmpOutErrors (1.3.6.1.2.1.5.15)  
The number of ICMP messages which this entity did not send due to problems  
discovered within ICMP, such as a lack of buffers. This value should not include  
errors discovered outside the ICMP layer such as the inability of IP to route the  
resultant datagram. In some implementations, there may be no types of errors  
which contribute to this counter's value.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutDestUnreachs (1.3.6.1.2.1.5.16)  
The number of ICMP Destination Unreachable messages sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutTimeExcds (1.3.6.1.2.1.5.17)  
The number of ICMP Time Exceeded messages sent.  
Syntax  
Counter  
Access  
read-only  
4-34  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The ICMP Group  
A
Status  
mandatory  
icmpOutParmProbs (1.3.6.1.2.1.5.18)  
The number of ICMP Parameter Problem messages sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutSrcQuenchs (1.3.6.1.2.1.5.19)  
The number of ICMP Source Quench messages sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutRedirects (1.3.6.1.2.1.5.20)  
The number of ICMP Redirect messages sent. For a host, this object will always  
be zero, since hosts do not send redirects.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutEchos (1.3.6.1.2.1.5.21)  
The number of ICMP Echo (request) messages sent.  
59047-09 C  
4-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The ICMP Group  
S
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutEchoReps (1.3.6.1.2.1.5.22)  
The number of ICMP Echo Reply messages sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutTimestamps (1.3.6.1.2.1.5.23)  
The number of ICMP Timestamp (request) messages sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutTimestampReps (1.3.6.1.2.1.5.24)  
The number of ICMP Timestamp Reply messages sent.  
Syntax  
Counter  
Access  
read-only  
4-36  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The TCP Group  
A
Status  
mandatory  
icmpOutAddrMasks (1.3.6.1.2.1.5.25)  
The number of ICMP Address Mask Request messages sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
icmpOutAddrMaskReps (1.3.6.1.2.1.5.26)  
The number of ICMP Address Mask Reply messages sent.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
The TCP Group  
Implementation of the TCP group is mandatory for all systems that implement the  
TCP. Instances of object types that represent information about a particular TCP  
connection are transient; they persist only as long as the connection in question.  
tcpRtoAlgorithm (1.3.6.1.2.1.6.1)  
The algorithm used to determine the timeout value used for retransmitting  
unacknowledged octets.  
Syntax  
INTEGER  
Access  
read-only  
59047-09 C  
4-37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The TCP Group  
S
Status  
mandatory  
tcpRtoMin (1.3.6.1.2.1.6.2)  
The minimum value permitted by a TCP implementation for the retransmission  
timeout, measured in milliseconds. More refined semantics for objects of this type  
depend upon the algorithm used to determine the retransmission timeout. In  
particular, when the timeout algorithm is rsre(3), an object of this type has the  
semantics of the LBOUND quantity described in RFC 793.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
tcpRtoMax (1.3.6.1.2.1.6.3)  
The maximum value permitted by a TCP implementation for the retransmission  
timeout, measured in milliseconds. More refined semantics for objects of this type  
depend upon the algorithm used to determine the retransmission timeout. In  
particular, when the timeout algorithm is rsre(3), an object of this type has the  
semantics of the UBOUND quantity described in RFC 793.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
tcpMaxConn (1.3.6.1.2.1.6.4)  
The limit on the total number of TCP connections the entity can support. In entities  
where the maximum number of connections is dynamic, this object should contain  
the value -1.  
Syntax  
INTEGER  
4-38  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The TCP Group  
A
Access  
read-only  
Status  
mandatory  
tcpActiveOpens (1.3.6.1.2.1.6.5)  
The number of times TCP connections have made a direct transition to the  
SYN-SENT state from the CLOSED state.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
tcpPassiveOpens (1.3.6.1.2.1.6.6)  
The number of times TCP connections have made a direct transition to the  
SYN-RCVD state from the LISTEN state.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
tcpAttemptFails (1.3.6.1.2.1.6.7)  
The number of times TCP connections have made a direct transition to the  
CLOSED state from either the SYN-SENT state or the SYN-RCVD state, plus the  
number of times TCP connections have made a direct transition to the LISTEN  
state from the SYN-RCVD state.  
Syntax  
Counter  
Access  
read-only  
59047-09 C  
4-39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The TCP Group  
S
Status  
mandatory  
tcpEstabResets (1.3.6.1.2.1.6.8)  
The number of times TCP connections have made a direct transition to the  
CLOSED state from either the ESTABLISHED state or the CLOSE-WAIT state.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
tcpCurrEstab (1.3.6.1.2.1.6.9)  
The number of TCP connections for which the current state is either  
ESTABLISHED or CLOSE-WAIT.  
Syntax  
Gauge  
Access  
read-only  
Status  
mandatory  
tcpInSegs (1.3.6.1.2.1.6.10)  
The total number of segments received, including those received in error. This  
count includes segments received on currently established connections.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
4-40  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The TCP Connection Table  
A
tcpOutSegs (1.3.6.1.2.1.6.11)  
The total number of segments sent including those on current connections, but  
excluding those containing only retransmitted octets.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
tcpRetransSegs (1.3.6.1.2.1.6.12)  
The total number of segments retransmitted. That is, the number of TCP  
segments transmitted containing one or more previously transmitted octets.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
The TCP Connection Table  
The TCP connection table contains information about this entity's existing TCP  
connections.  
tcpConnState (1.3.6.1.2.1.6.13.1.1)  
The state of this TCP connection. The only value which may be set by a  
management station is deleteTCB(12). Accordingly, it is appropriate for an agent  
to return a “badValue” response if a management station attempts to set this  
object to any other value.  
If a management station sets this object to the value deleteTCB(12), then this has  
the effect of deleting the TCB (as defined in RFC 793) of the corresponding  
connection on the managed Node. The result is an immediate termination of the  
connection.  
Syntax  
INTEGER  
59047-09 C  
4-41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The TCP Connection Table  
S
Access  
read-write  
Status  
mandatory  
Return Value  
Writes not supported.  
tcpConnLocalAddress (1.3.6.1.2.1.6.13.1.2)  
The local IP address for this TCP connection. In the case of a connection in the  
listen state which is willing to accept connections for any IP interface associated  
with the Node, the value 0.0.0.0 is used.  
Syntax  
IpAddress  
Access  
read-only  
Status  
mandatory  
tcpConnLocalPort (1.3.6.1.2.1.6.13.1.3)  
The local port number for this TCP connection.  
Syntax  
INTEGER (0..65535)  
Access  
read-only  
Status  
mandatory  
tcpConnRemAddress (1.3.6.1.2.1.6.13.1.4)  
The remote IP address for this TCP connection.  
Syntax  
IpAddress  
Access  
read-only  
4-42  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
Additional TCP Objects  
A
Status  
mandatory  
tcpConnRemPort (1.3.6.1.2.1.6.13.1.5)  
The remote port number for this TCP connection.  
Syntax  
INTEGER (0..65535)  
Access  
read-only  
Status  
mandatory  
Additional TCP Objects  
Following are the additional TCP objects.  
tcpInErrs (1.3.6.1.2.1.6.14)  
The total number of segments received in error (for example, bad TCP  
checksums).  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
tcpOutRsts (1.3.6.1.2.1.6.15)  
The number of TCP segments sent containing the RST flag.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The UDP Group  
S
The UDP Group  
Implementation of the UDP group is mandatory for all systems which implement  
the UDP.  
udpInDatagrams (1.3.6.1.2.1.7.1)  
The total number of UDP datagrams delivered to UDP users.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
udpNoPorts (1.3.6.1.2.1.7.2)  
The total number of received UDP datagrams for which there was no application  
at the destination port.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
udpInErrors (1.3.6.1.2.1.7.3)  
The number of received UDP datagrams that could not be delivered for reasons  
other than the lack of an application at the destination port.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
4-44  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The UDP Listener Table  
A
udpOutDatagrams (1.3.6.1.2.1.7.4)  
The total number of UDP datagrams sent from this entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
The UDP Listener Table  
The UDP listener table contains information about this entity's UDP end-points on  
which a local application is currently accepting datagrams.  
udpLocalAddress (1.3.6.1.2.1.7.5.1.1)  
The local IP address for this UDP listener. In the case of a UDP listener which is  
willing to accept datagrams for any IP interface associated with the Node, the  
value 0.0.0.0 is used.  
Syntax  
IpAddress  
Access  
read-only  
Status  
mandatory  
udpLocalPort (1.3.6.1.2.1.7.5.1.2)  
The local port number for this UDP listener.  
Syntax  
INTEGER (0..65535)  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The EGP Group  
S
The EGP Group  
Implementation of the EGP group is mandatory for all systems which implement  
the EGP.  
egpInMsgs (1.3.6.1.2.1.8.1)  
The number of EGP messages received without error.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpInErrors (1.3.6.1.2.1.8.2)  
The number of EGP messages received that proved to be in error.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpOutMsgs (1.3.6.1.2.1.8.3)  
The total number of locally generated EGP messages.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
4-46  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The EGP Neighbor Table  
A
egpOutErrors (1.3.6.1.2.1.8.4)  
The number of locally generated EGP messages not sent due to resource  
limitations within an EGP entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
The EGP Neighbor Table  
The EGP neighbor table contains information about this entity's EGP neighbors.  
egpNeighState (1.3.6.1.2.1.8.5.1.1)  
The EGP state of the local system with respect to this entry's EGP neighbor. Each  
EGP state is represented by a value that is one greater than the numerical value  
associated with the state in RFC 904.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
egpNeighAddr (1.3.6.1.2.1.8.5.1.2)  
The IP address of this entry's EGP neighbor.  
Syntax  
IpAddress  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The EGP Neighbor Table  
S
egpNeighAs (1.3.6.1.2.1.8.5.1.3)  
The autonomous system of this EGP peer. Zero should be specified if the  
autonomous system number of the neighbor is not yet known.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
egpNeighInMsgs (1.3.6.1.2.1.8.5.1.4)  
The number of EGP messages received without error from this EGP peer.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpNeighInErrs (1.3.6.1.2.1.8.5.1.5)  
The number of EGP messages received from this EGP peer that proved to be in  
error (for example, bad EGP checksum).  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpNeighOutMsgs (1.3.6.1.2.1.8.5.1.6)  
The number of locally generated EGP messages to this EGP peer.  
Syntax  
Counter  
4-48  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The EGP Neighbor Table  
A
Access  
read-only  
Status  
mandatory  
egpNeighOutErrs (1.3.6.1.2.1.8.5.1.7)  
The number of locally generated EGP messages not sent to this EGP peer due to  
resource limitations within an EGP entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpNeighInErrMsgs (1.3.6.1.2.1.8.5.1.8)  
The number of EGP-defined error messages received from this EGP peer.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpNeighOutErrMsgs (1.3.6.1.2.1.8.5.1.9)  
The number of EGP-defined error messages sent to this EGP peer.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The EGP Neighbor Table  
S
egpNeighStateUps (1.3.6.1.2.1.8.5.1.10)  
The number of EGP state transitions to the UP state with this EGP peer.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpNeighStateDowns (1.3.6.1.2.1.8.5.1.11)  
The number of EGP state transitions from the UP state to any other state with this  
EGP peer.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
egpNeighIntervalHello (1.3.6.1.2.1.8.5.1.12)  
The interval between EGP Hello command retransmissions, in hundredths of a  
second. This represents the t1 timer as defined in RFC 904.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
egpNeighIntervalPoll (1.3.6.1.2.1.8.5.1.13)  
The interval between EGP poll command retransmissions, in hundredths of a  
second. This represents the t3 timer as defined in RFC 904.  
4-50  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The EGP Neighbor Table  
A
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
egpNeighMode (1.3.6.1.2.1.8.5.1.14)  
The polling mode of this EGP entity, either passive or active.  
Syntax  
INTEGER { active(1), passive(2) }  
Access  
read-only  
Status  
mandatory  
egpNeighEventTrigger (1.3.6.1.2.1.8.5.1.15)  
A control variable used to trigger operator-initiated Start and Stop events. When  
read, this variable always returns the most recent value that  
egpNeighEventTrigger was set to. If it has not been set since the last initialization  
of the network management subsystem on the Node, it returns a value of “stop”.  
When set, this variable causes a Start or Stop event on the specified neighbor, as  
specified on pages 8-10 of RFC 904. Briefly, a Start event causes an Idle peer to  
begin neighbor acquisition and a non-Idle peer to re-initiate neighbor acquisition.  
A stop event causes a non-Idle peer to return to the Idle state until a Start event  
occurs, either by egpNeighEventTrigger or otherwise.  
Syntax  
INTEGER { start(1), stop(2) }  
Access  
read-write  
Status  
mandatory  
59047-09 C  
4-51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4 – MIB-II Objects  
The Transmission Group  
S
egpAs (1.3.6.1.2.1.8.6)  
The autonomous system number of this EGP entity.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
The Transmission Group  
Based on the transmission media underlying each interface on a system, the  
corresponding portion of the Transmission group is mandatory for that system.  
When Internet-standard definitions for managing transmission media are defined,  
the transmission group is used to provide a prefix for the names of those objects.  
Typically, such definitions reside in the experimental portion of the MIB until they  
are "proven", then as a part of the Internet standardization process, the definitions  
are accordingly elevated and a new object identifier, under the transmission group  
is defined. By convention, the name assigned is:  
type OBJECT IDENTIFIER ::= { transmission number }.  
Where "type" is the symbolic value used for the media in the ifType column of the  
ifTable object, and "number" is the actual integer value corresponding to the  
symbol.  
The SNMP Group  
Implementation of the SNMP group is mandatory for all systems which support an  
SNMP protocol entity. Some of the objects defined below will be zero-valued in  
those SNMP implementations that are optimized to support only those functions  
specific to either a management agent or a management station. In particular, it  
should be observed that the objects below refer to an SNMP entity, and there may  
be several SNMP entities residing on a managed Node.  
snmpInPkts (1.3.6.1.2.1.11.1)  
The total number of messages delivered to the SNMP entity from the transport  
service.  
Syntax  
Counter  
4-52  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The SNMP Group  
A
Access  
read-only  
Status  
mandatory  
snmpOutPkts (1.3.6.1.2.1.11.2)  
The total number of SNMP messages passed from the SNMP protocol entity to  
the transport service.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInBadVersions (1.3.6.1.2.1.11.3)  
The total number of SNMP messages delivered to the SNMP protocol entity and  
were for an unsupported SNMP version.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInBadCommunityNames (1.3.6.1.2.1.11.4)  
The total number of SNMP messages delivered to the SNMP protocol entity which  
used a SNMP community name not known to the entity.  
Syntax  
Counter  
Access  
read-only  
59047-09 C  
4-53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The SNMP Group  
S
Status  
mandatory  
snmpInBadCommunityUses (1.3.6.1.2.1.11.5)  
The total number of SNMP messages delivered to the SNMP protocol entity which  
represented an SNMP operation which was not allowed by the SNMP community  
named in the message.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInASNParseErrs (1.3.6.1.2.1.11.6)  
The total number of ASN.1 or BER errors encountered by the SNMP protocol  
entity when decoding received SNMP messages.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInTooBigs (1.3.6.1.2.1.11.8)  
The total number of SNMP PDUs delivered to the SNMP protocol entity and for  
which the value of the error-status field is “tooBig”.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
4-54  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The SNMP Group  
A
snmpInNoSuchNames (1.3.6.1.2.1.11.9)  
The total number of SNMP PDUs delivered to the SNMP protocol entity and for  
which the value of the error-status field is "NoSuchName".  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInBadValues (1.3.6.1.2.1.11.10)  
The total number of SNMP PDUs delivered to the SNMP protocol entity and for  
which the value of the error-status field is “badValue”.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInReadOnlys (1.3.6.1.2.1.11.11)  
The total number valid SNMP PDUs delivered to the SNMP protocol entity and for  
which the value of the error-status field is “readOnly”. It should be noted that it is a  
protocol error to generate an SNMP PDU which contains the value ”readOnly” in  
the error-status field, as such, this object is provided as a means of detecting  
incorrect implementations of the SNMP.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The SNMP Group  
S
snmpInGenErrs (1.3.6.1.2.1.11.12)  
The total number of SNMP PDUs delivered to the SNMP protocol entity and for  
which the value of the error-status field is “genErr”.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInTotalReqVars (1.3.6.1.2.1.11.13)  
The total number of MIB objects retrieved successfully by the SNMP protocol  
entity as the result of receiving valid SNMP Get-Request and Get-Next PDUs.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInTotalSetVars (1.3.6.1.2.1.11.14)  
The total number of MIB objects altered successfully by the SNMP protocol entity  
as the result of receiving valid SNMP Set-Request PDUs.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInGetRequests (1.3.6.1.2.1.11.15)  
The total number of SNMP Get-Request PDUs accepted and processed by the  
SNMP protocol entity.  
4-56  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The SNMP Group  
A
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInGetNexts (1.3.6.1.2.1.11.16)  
The total number of SNMP Get-Next PDUs accepted and processed by the SNMP  
protocol entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInSetRequests (1.3.6.1.2.1.11.17)  
The total number of SNMP Set-Request PDUs accepted and processed by the  
SNMP protocol entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpInGetResponses (1.3.6.1.2.1.11.18)  
The total number of SNMP Get-Response PDUs accepted and processed by the  
SNMP protocol entity.  
Syntax  
Counter  
59047-09 C  
4-57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The SNMP Group  
S
Access  
read-only  
Status  
mandatory  
snmpInTraps (1.3.6.1.2.1.11.19)  
The total number of SNMP Trap PDUs accepted and processed by the SNMP  
protocol entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpOutTooBigs (1.3.6.1.2.1.11.20)  
The total number of SNMP PDUs generated by the SNMP protocol entity and for  
which the value of the error-status field is “tooBig”'  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpOutNoSuchNames (1.3.6.1.2.1.11.21)  
The total number of SNMP PDUs generated by the SNMP protocol entity and for  
which the value of the error-status is "NoSuchName".  
Syntax  
Counter  
Access  
read-only  
4-58  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The SNMP Group  
A
Status  
mandatory  
snmpOutBadValues (1.3.6.1.2.1.11.22)  
The total number of SNMP PDUs generated by the SNMP protocol entity and for  
which the value of the error-status field is “badValue”.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpOutGenErrs (1.3.6.1.2.1.11.24)  
The total number of SNMP PDUs generated by the SNMP protocol entity and for  
which the value of the error-status field is “genErr”.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpOutGetRequests (1.3.6.1.2.1.11.25)  
The total number of SNMP Get-Request PDUs generated by the SNMP protocol  
entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
59047-09 C  
4-59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
4 – MIB-II Objects  
The SNMP Group  
S
snmpOutGetNexts (1.3.6.1.2.1.11.26)  
The total number of SNMP Get-Next PDUs generated by the SNMP protocol  
entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpOutSetRequests (1.3.6.1.2.1.11.27)  
The total number of SNMP Set-Request PDUs generated by the SNMP protocol  
entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpOutGetResponses (1.3.6.1.2.1.11.28)  
The total number of SNMP Get-Response PDUs generated by the SNMP protocol  
entity.  
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpOutTraps (1.3.6.1.2.1.11.29)  
The total number of SNMP Trap PDUs generated by the SNMP protocol entity.  
4-60  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
4 – MIB-II Objects  
The SNMP Group  
A
Syntax  
Counter  
Access  
read-only  
Status  
mandatory  
snmpEnableAuthenTraps (1.3.6.1.2.1.11.30)  
Indicates whether the SNMP agent process is permitted to generate  
authentication-failure traps. The value of this object overrides any configuration  
information; as such, it provides a means whereby all authentication-failure traps  
may be disabled.  
It is strongly recommended that this object be stored in non-volatile memory so  
that it remains constant between re-initializations of the network management  
system.  
Syntax  
INTEGER { enabled(1), disabled(2) }  
Access  
read-write  
Status  
mandatory  
Return Value  
Read returns enabled (1) if AuthFailureTrap = True, otherwise disabled (2).  
Writes not supported.  
59047-09 C  
4-61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4 – MIB-II Objects  
The SNMP Group  
S
Notes  
4-62  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 Fibre Alliance MIB Objects  
This section covers the implementation details for the Fibre Alliance Management  
Information Bases (FA-MIB) version 6.0 on the SANbox switch.  
FA MIB Definitions  
The FA-MIB version 4.0 is a collection of structured objects that resides on the  
workstation with the manager application. These objects define the syntax for  
information exchanged between the manager and the agent. The textual  
substitutions in Table 5-1 are specific to the FA-MIB and can be used in place of  
primitive data types.  
Table 5-1. FA-MIB Textual Substitutions  
Description  
Syntax  
FcNameId  
FcGlobalId  
FcAddressId  
OCTET STRING (SIZE(8))  
OCTET STRING (SIZE(16))  
OCTET STRING (SIZE(3))  
FcEventSeverity INTEGER {  
unknown (1),  
emergency (2),  
alert (3),  
critical (4),  
error (5),  
warning (6),  
notify (7),  
info (8),  
debug (9),  
mark (10) - All messages logged  
}
59047-09 C  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
FA MIB Definitions  
S
Table 5-1. FA-MIB Textual Substitutions (Continued)  
Description  
Syntax  
FcUnitType  
INTEGER {  
unknown(1)  
other(2) - none of the following  
hub(3) - passive connectivity unit supporting loop protocol.  
switch(4) - active connectivity unit supporting multiple protocols.  
gateway(5) - unit that converts not only the interface but also  
encapsulates the frame into another protocol. The assumption is  
that there is always two gateways connected together. For exam-  
ple, FC <-> ATM.  
converter(6) - unit that converts from one interface to another. For  
example, FC <-> SCSI.  
hba(7) - host bus adapter  
proxy-agent(8) - software proxy-agent  
storage-device(9) - disk, cd, tape, etc.  
host(10) - host computer  
storage-subsystem(11) - raid, library, etc.  
module(12) - subcomponent of a system  
swdriver(13) - software driver  
storage-access-device(14) - Provides storage management and  
access for heterogeneous hosts and heterogeneous devices  
wdm(15) - waveform division multiplexer  
ups(16) - uninterruptable power supply  
}
revisionNumber  
The revision number for this MIB. The format of the revision value is as follows:  
(0) = high order major revision number  
(1) = low order major revision number  
(2) = high order minor revision number  
(3) = low order minor revision number  
The value will be stored as an ASCII value. The following is the current value of  
04.00 for this object.  
(0) = '0'  
(1) = '4'  
5-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Connectivity Unit Group  
A
(2) = '0'  
(3) = '0'  
Syntax  
DisplayString (SIZE (4))  
Access  
read-only  
Status  
mandatory  
Return Value  
A four digit ASCII value (for example, 0400 for MIB revision 4.0).  
Connectivity Unit Group  
The objects described in this section are not in a table format. An example of how  
to access one of these objects is:  
"snmpget localhost public fcmgmt.connSet.uNumber.0".  
uNumber (1.3.6.1.3.94.1.1)  
The number of connectivity units present on this system (represented by this  
agent). May be a count of the boards in a chassis or the number of full boxes in a  
rack.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The number of switches in fabric.  
systemURL (1.3.6.1.3.94.1.2)  
The top-level URL of the system. If it does not exist, the value is an empty string.  
The URL format is implementation dependant and can have keywords embedded  
that are preceded by a percent sign (for example, %USER).  
59047-09 C  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Connectivity Unit Group  
S
Syntax  
DisplayString  
Access  
read-write  
Status  
mandatory  
Return Value  
The switch IP address. For example, http://10.0.0.1. Writes not supported,  
returns 'NoSuchName".  
statusChangeTime (1.3.6.1.3.94.1.3)  
The sysUpTime timestamp at which the last status change occurred for any  
members of the set, in centiseconds.  
Syntax  
TimeTicks  
Access  
read only  
Status  
obsolete  
Return Value  
The sysUpTime timestamp at which the last status change occurred.  
configurationChangeTime (1.3.6.1.3.94.1.4)  
The sysUpTime timestamp at which the last configuration change occurred for  
any members of the set, in centiseconds. This represents a union of change  
information for connUnitConfigurationChangeTime.  
Syntax  
TimeTicks  
Access  
read only  
Status  
obsolete  
5-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
Return Value  
The sysUpTime timestamp at which the last configuration change occurred.  
connUnitTableChangeTime (1.3.6.1.3.94.1.5)  
The sysUpTime timestamp at which the connUnitTable was updated (an entry was  
either added or deleted), in centiseconds.  
Syntax  
TimeTicks  
Access  
read only  
Status  
obsolete  
Return Value  
The sysUpTime timestamp at which the connUnitTable was updated.  
Connectivity Table  
The objects described in this section are in a table format indexed by switch World  
Wide Name. An example of how to access one of these objects given a WWN of  
100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.connSet.connUnitTable.connUnitEntry.connUnitId..16.0.0.192.  
221.0.144.167.0.0.0.0.0.0.0.0".  
connUnitId (1.3.6.1.3.94.1.6.1.1)  
The unique identification for this connectivity unit among those within this proxy  
domain. The value must be unique within the proxy domain because it is the index  
variable for connUnitTable. The value assigned to a given connectivity unit should  
be persistent across agent and unit resets. It should be the same as  
connUnitGlobalId if connUnitGlobalId is known and stable.  
Syntax  
FcGlobalId  
Access  
read-only  
59047-09 C  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
Status  
mandatory  
Return Value  
The World Wide Name of the switch followed by 8 bytes of zeros. For  
example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitGlobalId (1.3.6.1.3.94.1.6.1.2)  
An optional global-scope identifier for this connectivity unit. It must be a WWN for  
this connectivity unit or 16 octets of value zero.  
Syntax  
connUnitGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
The World Wide Name of the switch followed by 8 bytes of zeros. For  
example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitType (1.3.6.1.3.94.1.6.1.3)  
The type of this connectivity unit.  
Syntax  
FcUnitType  
Access  
read-only  
Status  
mandatory  
Return Value  
switch (4)  
connUnitNumports (1.3.6.1.3.94.1.6.1.4)  
Number of physical ports in the connectivity unit (internal/embedded, external).  
5-6  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The number of ports on the switch.  
connUnitState (1.3.6.1.3.94.1.6.1.5)  
The operational state of the switch mapped. The overall state of connectivity unit.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-2 for switch operational states.  
Table 5-2. Switch Operational States  
Switch State  
Return State  
online  
online (2)  
offline (3)  
offline (3)  
unknown (1)  
offline  
diagnostics  
other  
connUnitStatus (1.3.6.1.3.94.1.6.1.6)  
Overall status of the connectivity unit. The goal of this object is to be the single  
poll point to check the status of the connunit. If there is any other component that  
has warning, then this should be set to warning. any of these values may occur  
with any of the ConnUnitState values.  
59047-09 C  
5-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-3 for connectivity unit return values. Return value will be OK  
(3), unless one or more of the following occurs.  
Table 5-3. SANbox 5000 Series Connectivity Unit Return Values  
Status  
Return Value  
If one power supply is reporting Bad  
and/or not installed  
warning (4)  
failed (5)  
If both power supplies are reporting Bad  
and/or not installed  
If one or more cooling fan failed  
If all cooling fans failed  
warning (4)  
failed (5)  
If temperature status = "Warm"  
If temperature status = "Overheating"  
If any port down  
warning (4)  
failed (5)  
warning (4)  
failed (5)  
If POST failed  
If switch Offline or in Diagnostics mode  
warning (4)  
Refer to Table 5-4 for connectivity unit return values. Return value will be OK  
(3), uninstalled IO or CPU boards are ignored  
Table 5-4. SANbox 9000 Series Connectivity Unit Return Values  
Status  
Return Value  
If either FAN or PS boards are not installed warning (4)  
If all FANs or all PS boards are not  
installed  
failed (5)  
5-8  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
Table 5-4. SANbox 9000 Series Connectivity Unit Return Values  
Status  
Return Value  
If installed board's faultList is not NONE  
warning (4)  
connUnitProduct (1.3.6.1.3.94.1.6.1.7)  
The sml attribute Config.Snmp.SysDescr. This is the system description shown on  
the 'show version' telnet screen. It can also be read on the 'show setup snmp'  
screen and written using the 'set setup snmp' Telnet screen.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the switch SystemDescription: SANbox 5200 = SANbox 5200 FC  
Switch, SANbox 5202 = SANbox 5602 FC Switch, SANbox 5600 = SANbox  
5600 FC Switch, SANbox 5602 = SANbox 5602 FC Switch, SANbox 9100 =  
SANbox 9100 FC Switch, SANbox 9200 = SANbox 9200 FC Switch.  
connUnitSn (1.3.6.1.3.94.1.6.1.8)  
The serial number for this connectivity unit.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
The chassis serial number.  
connUnitUpTime (1.3.6.1.3.94.1.6.1.9)  
The number of centiseconds since the last unit initialization.  
59047-09 C  
5-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
Syntax  
TimeTicks  
Access  
read-only  
Status  
mandatory  
Return Value  
The time interval since either POST or a reset (not including hotreset  
command for the NDCLA feature). POST (Power-On Self-Test) occurs  
during Power-On, or hardreset.  
connUnitUrl (1.3.6.1.3.94.1.6.1.10)  
URL to launch a management application, if applicable. Otherwise, it’s an empty  
string. In a standalone unit, this would be the same as the top-level URL. This has  
the same definition as systemURL for keywords. If write is not supported, then the  
return value is invalid. This value will be retained across boots.  
Syntax  
DisplayString  
Access  
read-write  
Status  
mandatory  
Return Value  
The switch IP address. For example, http://10.0.0.1. Writes not supported,  
returns 'NoSuchName".  
connUnitDomainId (1.3.6.1.3.94.1.6.1.11  
24 bit Fibre Channel address ID of this connectivity unit, right justified with leading  
zeros if required. This should be set to the Fibre Channel address ID, or if it is a  
switch, it would be set to the Domain Controller address. If this value is not  
applicable, return all bits set to one.  
Syntax  
OCTET STRING (SIZE(3))  
5-10  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
The domain controller address. For example, FF FC 65.  
connUnitProxyMaster (1.3.6.1.3.94.1.6.1.12)  
A value of “yes” means this is the proxy master unit for a set of managed units.  
For example, this could be the only unit with a management card in it for a set of  
units. A standalone unit should return “yes” for this object.  
Syntax  
INTEGER {  
unknown(1),  
no(2),  
yes(3)  
}
Access  
read-only  
Status  
mandatory  
Return Value  
If out-of-band switch, returns yes (3). If in-band switch, returns no (2).  
59047-09 C  
5-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
connUnitPrincipal (1.3.6.1.3.94.1.6.1.13)  
Whether this connectivity unit is the principal unit within the group of fabric  
elements. If this value is not applicable, the return is unknown.  
Syntax  
INTEGER {  
unknown(1),  
no(2),  
yes(3)  
}
Access  
read-only  
Status  
mandatory  
Return Value  
For the principal switch, returns yes (3); otherwise returns no (2).  
connUnitNumSensors (1.3.6.1.3.94.1.6.1.14)  
Number of sensors in the connUnitSensorTable elements. If this value is not  
applicable, return unknown.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the number of sensors listed in the connUnitSensorTable. SANbox  
5200 = 3, SANbox 5202 = 6, SANbox 5600 = 3, SANbox 5602 = 6, SANbox  
9000 Series is dependent on number of blades installed  
5-12  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
connUnitStatusChangeTime (1.3.6.1.3.94.1.6.1.15)  
The sysUpTime timestamp, in centiseconds, at which the last status change  
occurred.  
Syntax  
TimeTicks  
Access  
read-only  
Status  
obsolete  
Return Value  
This object is obsolete. Always returns error status "NoSuchName".  
connUnitConfigurationChangeTime (1.3.6.1.3.94.1.6.1.16)  
The sysUpTime timestamp, in centiseconds, at which the last configuration  
change occurred.  
Syntax  
TimeTicks  
Access  
read-only  
Status  
obsolete  
Return Value  
This object is obsolete. Always returns error status "NoSuchName".  
59047-09 C  
5-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
connUnitNumRevs (1.3.6.1.3.94.1.6.1.17)  
The number of revisions in the connUnitRevsTable.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The number of entries in the revision table. The revision numbers of all  
components of the switch. SANbox 5200 = 3, SANbox 5202 = 3, SANbox  
5600 = 3, SANbox 5602 = 3, SANbox 9000 Series is dependent on number  
of blades installed  
connUnitNumZones (1.3.6.1.3.94.1.6.1.18)  
Number of zones defined in connUnitZoneTable.  
Syntax  
INTEGER  
Access  
read-only  
Status  
obsolete  
Return Value  
This object is obsolete. Always returns error status "NoSuchName".  
5-14  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
connUnitModuleId (1.3.6.1.3.94.1.6.1.19)  
This is a unique ID, persistent between boots, that can be used to group a set of  
connUnits together into a module. The intended use would be to create a  
connUnit with a connUnitType of “module” to represent a physical or logical group  
of connectivity units. Then, the value of the group would be set to the value of  
connUnitId for this “container” connUnit. connUnitModuleId should be zeros if this  
connUnit is not part of a module.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
The World Wide Name of the switch followed by 8 bytes of zeros. For  
example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitName (1.3.6.1.3.94.1.6.1.20)  
A display string containing a name for this connectivity unit. This object value  
should be persistent between boots.  
Syntax  
DisplayString (SIZE(0..79))  
Access  
read-write  
Status  
mandatory  
Return Value  
The SymbolicName of Switch. The default's are: SANbox 5200 = SANbox,  
SANbox 5202 = SANbox, SANbox 5600 = SANbox, SANbox 5602 =  
SANbox, SANbox 9100 = SANbox, SANbox 9200 = SANbox  
59047-09 C  
5-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
connUnitInfo (1.3.6.1.3.94.1.6.1.21)  
A display string containing information about this connectivity unit. This object  
value should be persistent between boots.  
Syntax  
DisplayString  
Access  
read-write  
Status  
mandatory  
Return Value  
Returns the ConfigDescription field for the switch. The default for SANbox  
5000/9000 Series = Default Config.  
connUnitControl (1.3.6.1.3.94.1.6.1.22)  
This object is used to control the addressed connUnit. “Cold Start” and “Warm  
Start” are as defined in MIB-II and are not meant to be a factory reset.  
resetConnUnitColdStart: the addressed unit performs a “Cold Start” reset.  
resetConnUnitWarmStart: the addressed unit performs a “Warm Start” reset.  
offlineConnUnit: the addressed unit puts itself into an implementation  
dependant “offline” state. In general, if a unit is in an offline state, it cannot  
be used to perform meaningful Fibre Channel work.  
onlineConnUnit: the addressed unit puts itself into an implementation  
dependant “online” state. In general, if a unit is in an online state, it is  
capable of performing meaningful Fibre Channel work.  
Each implementation may chose not to allow any or all of these values on a SET.  
Syntax  
INTEGER {  
unknown(1),  
invalid(2),  
resetConnUnitColdStart(3),  
resetConnUnitWarmStart(4),  
offlineConnUnit(5),  
onlineConnUnit(6)  
}
5-16  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
Access  
read-write  
Status  
mandatory  
Return Value  
Refer to the following tables for connUnitControl values.  
Table 5-5. connUnitContol Read Return Values  
Switch Setting Return Value  
Online  
Online (6)  
Offline (5)  
Offline (5)  
Unknown (1)  
Offline  
Diagnostics  
Other  
Table 5-6. connUnitContol Write Control Values  
Control Value Result  
Cold Reset (3)  
Offline (5)  
Online (6)  
other  
Reset  
Offline  
Online  
Not supported  
connUnitContact (1.3.6.1.3.94.1.6.1.23)  
Contact information for this connectivity unit, and is persistent across boots.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-write  
Status  
mandatory  
59047-09 C  
5-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
Return Value  
The default is: <sysContact undefined>. The string size is limited to a  
maximum of 64.  
connUnitLocation (1.3.6.1.3.94.1.6.1.24)  
Location information for this connectivity unit, and is persistent across boots.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-write  
Status  
mandatory  
Return Value  
The default is: <sysLocation undefined>. The string size is limited to a  
maximum of 64.  
connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)  
This value defines the event severity that will be logged by this connectivity unit.  
All events of severity less than or equal to connUnitEventFilter are logged in  
connUnitEventTable.  
Syntax  
FcEventSeverity  
Access  
read-write  
Status  
mandatory  
Return Value  
The switch log level setting. Refer to the following tables for  
connUnitEventFilter values.  
Table 5-7. connUnitEventFilter Read Return Values  
Severity Levels  
Return Value  
Critical  
Critical (4)  
5-18  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Connectivity Table  
A
Table 5-7. connUnitEventFilter Read Return Values  
Severity Levels Return Value  
Warn  
Info  
Warning (6)  
Info (8)  
None  
Unknown (1)  
Table 5-8. connUnitEventFilter Control Write Values  
Control Value Result  
Emergency (2)  
Alert (3)  
Critical  
Critical  
Critical  
Warn  
Warn  
Info  
Critical (4)  
Error (5)  
Warning (6)  
Notify (7)  
Info (8)  
Info  
Debug (9)  
Mark (10)  
Unknown (1)  
Info  
Info  
None  
connUnitNumEvents (1.3.6.1.3.94.1.6.1.26)  
Number of events currently in the connUnitEventTable.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
An integer indicating the number of events in the event table.  
59047-09 C  
5-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Connectivity Table  
S
connUnitMaxEvents (1.3.6.1.3.94.1.6.1.27)  
Maximum number of events that can be defined in connUnitEventTable.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns 30.  
connUnitEventCurrID (1.3.6.1.3.94.1.6.1.28)  
The last used event ID (connUnitEventIndex).  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The event ID of the last event.  
connUnitFabricID (1.3.6.1.3.94.1.6.1.29)  
A globally unique value to identify the fabric that this ConnUnit belongs to,  
otherwise empty string. This would typically be equal to the connUnitGlobalID of  
the primary switch in a Fibre Channel fabric.  
Syntax  
FcGlobalId  
MaxAccess  
read-only  
Status  
mandatory  
5-20  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Revision Table  
A
Return Value  
Returns the World Wide Name of the principal switch followed by 8 bytes of  
zeros. For example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitNumLinks (1.3.6.1.3.94.1.6.1.30)  
The number of links in the link table.  
Syntax  
INTEGER  
MaxAccess  
read-only  
Status  
mandatory  
Return Value  
Returns the number of link table entries for each switch.  
connUnitVendorId (1.3.6.1.3.94.1.6.1.31)  
The connectivity unit vendor's name.  
Syntax  
DisplayString (SIZE (0..79))  
read-only  
Status  
mandatory  
Return Value  
"QLogic"  
Revision Table  
The objects described in this section are in a table format indexed by World Wide  
Name and Index. The Table of revisions for hardware and software elements.  
There are four revision items in each switch. An example of how to access one of  
these objects given a WWN of 100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.connSet.connUnitRevsTable.connUnitRevsEntry.connUnitRevsUni  
tId.16.0.0.192.221.0.144.167.0.0.0.0.0.0.0.0.1".  
59047-09 C  
5-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Revision Table  
S
The number of entries in this table will be variable depending on which platform is  
being examined and the number of blades installed. SNMP first reports the  
firmware revision and flasher shell version. It then iterates through each of the  
installed blades reporting the PCB revision and ASIC version.  
connUnitRevsUnitId (1.3.6.1.3.94.1.7.1.1)  
The connUnitId of the connectivity unit that contains this revision table.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the World Wide Name of the switch followed by 8 bytes of zeros.  
For example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitRevsIndex (1.3.6.1.3.94.1.7.1.2)  
A unique value among all connUnitRevsEntrys with the same value of  
connUnitRevsUnitId, in the range between 1 and  
connUnitNumRevs[connUnitRevsUnitId].  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
The revision table index.  
connUnitRevsRevId (1.3.6.1.3.94.1.7.1.3)  
A vendor-specific string identifying a revision of a component of the connUnit  
indexed by connUnitRevsUnitId.  
Syntax  
DisplayString  
5-22  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Revision Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-9 for SANbox 5000/9000 Series connUnitRevsRevtId return  
values.  
Table 5-9. SANbox 5000/9000 Series ConnUnitRevsRevId Return Values  
Table Index  
Return Value  
1
2
3
Active Firmware Image  
Flasher Shell Version  
Hardware ASIC Version (1 per blade)  
connUnitRevsDescription (1.3.6.1.3.94.1.7.1.4)  
Description of a component to which the revision corresponds.  
Syntax  
DisplayString  
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-10 for SANbox 5200/5600 Series connUnitRevsDescription  
return values.  
Table 5-10. SANbox 5200/5600 Series ConnUnitRevsDescription Return  
Values  
Table Index  
Return Value  
1
2
Active Firmware Version  
Flasher Shell Version  
59047-09 C  
5-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Sensor Table  
S
Table 5-10. SANbox 5200/5600 Series ConnUnitRevsDescription Return  
Values  
Table Index  
Return Value  
3
Hardware ASIC Version  
Sensor Table  
The objects described in this section are in a table format indexed by World Wide  
Name and Index. The Index is the sensor number being interrogated. There are  
six sensor items in each switch. An example of how to access one of these  
objects given a WWN of 100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.connSet.connUnitSensorTable.connUnitSensorEntry.connUnitSen  
sorUnitId.16.0.0.192.221.0.144.167.0.0.0.0.0.0.0.0.1".  
connUnitSensorUnitId (1.3.6.1.3.94.1.8.1.1)  
The connUnitId of the connectivity unit that contains this sensor table.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the World Wide Name of the switch followed by 8 bytes of zeros.  
For example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitSensorIndex (1.3.6.1.3.94.1.8.1.2)  
A unique value among all connUnitSensorEntrys with the same value of  
connUnitSensorUnitId, in the range between 1 and  
connUnitNumSensor[connUnitSensorUnitId].  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
5-24  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Sensor Table  
A
Status  
mandatory  
Return Value  
The sensor table index.  
connUnitSensorName (1.3.6.1.3.94.1.8.1.3)  
A textual identification of the sensor intended primarily for operator use.  
Syntax  
DisplayString  
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-11 for SANbox 5200/5600 connUnitSensorName return  
values.  
Table 5-11. SANbox 5200/5600 ConnUnitSensorName Return Values  
Table Index  
Return Value  
1
2
3
Power Supply 1 Status  
Temperature Status  
Temperature Sensor 1 Value  
Refer to Table 5-12 for SANbox 5202/5602 connUnitSensorName return  
values.  
59047-09 C  
5-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Sensor Table  
S
Table 5-12. SANbox 5202/5602 ConnUnitSensorName Return Values  
Table Index Return Value  
1
2
3
4
5
6
Power Supply 1 Status  
Power Supply 2 Status  
Fan 1 Status  
Fan 2 Status  
Temperature Status  
Temperature Sensor 1 Value  
Refer to Table 5-12 for SANbox 9000 connUnitSensorName return values.  
Table 5-13. SANbox 9000 ConnUnitSensorName Return Values  
Table Index  
Return Value  
1
Power Supply 1 Status  
2
Power Supply 2 Status  
Fan 1 Status  
3
4
Fan 2 Status  
5-19  
20-45  
Temperature Status (1 value per blade)  
Temperature Value (I/O blades have 4 val-  
ues, CPU blades have 7 values)  
46-60  
Voltage Status (all blade types have 1  
value)  
connUnitSensorStatus (1.3.6.1.3.94.1.8.1.4)  
The status indicated by the sensor.  
Syntax  
INTEGER {  
unknown(1)  
other(2) - the sensor indicates other than ok (warning or failure).  
ok(3) - the sensor indicates ok  
warning(4) - the sensor indicates a warning  
failed(5) - the sensor indicates failure  
}
5-26  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Sensor Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to the following tables for connUnitSensorStatus return values.  
Table 5-14. ConnUnitSensorStatus Return Values for Board Temperature  
Switch Value Return Value  
Normal  
Warm  
OK (3)  
Warning (4)  
Failed (5)  
Unknown (1)  
Overheating  
Other  
Table 5-15. ConnUnitSensorStatus Return Values for Fan Status  
Switch Value Return Value  
Good  
Bad  
OK (3)  
Failed (5)  
Unknown (1)  
Other  
Table 5-16. ConnUnitSensorStatus Return Values for Voltage Status  
Switch Value Return Value  
Good  
Bad  
OK (3)  
Failed (5)  
Unknown (1)  
Other  
connUnitSensorInfo (1.3.6.1.3.94.1.8.1.5)  
Miscellaneous static information about the sensor, such as its serial number.  
Syntax  
DisplayString  
59047-09 C  
5-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Sensor Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns an empty string.  
connUnitSensorMessage (1.3.6.1.3.94.1.8.1.6)  
This describes the status of the sensor as a message. It may also provide more  
resolution on the sensor indication. For example, “Cover temperature 1503K,  
above nominal operating range” ::= { connUnitSensorEntry 6 }.  
Syntax  
DisplayString  
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-17 for SANbox 5200/5600 Series connUnitSensorMessage  
values.  
Table 5-17. ConnUnitSensorMessage Values  
Sensor  
Value  
Power Supply  
Fan  
Good/Bad/NotInstalled  
Good/Bad/NotInstalled  
Normal/Warm/Overheating/NotInstalled  
Degrees in C  
Temperature Status  
Temperature Value  
5-28  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Sensor Table  
A
connUnitSensorType (1.3.6.1.3.94.1.8.1.7)  
The type of component being monitored by this sensor.  
Syntax  
INTEGER {  
unknown(1),  
other(2),  
battery(3),  
fan(4),  
power-supply(5),  
transmitter(6),  
enclosure(7),  
board(8),  
receiver(9)  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-18 for connUnitSensorType return values.  
Table 5-18. ConnUnitSensorType Return Values  
Sensor Value  
Temperature  
Fan  
Board (8)  
Fan (4)  
Power Supply  
Voltage  
Power Supply (5)  
Board (8)  
59047-09 C  
5-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Sensor Table  
S
connUnitSensorCharacteristic (1.3.6.1.3.94.1.8.1.8)  
The characteristics being monitored by this sensor.  
Syntax  
INTEGER {  
unknown(1),  
other(2),  
temperature(3),  
pressure(4),  
emf(5),  
currentValue(6), - current is a keyword  
airflow(7),  
frequency(8),  
power(9),  
door(10)  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-19 for connUnitSensorCharacterisitic values.  
Table 5-19. ConnUnitSensorCharacteristic Values  
Sensor  
Value  
Temperature Value  
Temperature (3)  
Temperature (3)  
Airflow (7)  
Temperature Status  
Fan  
Power Supply  
Power (9)  
5-30  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Port Table  
A
Port Table  
The objects described in this section are in a table format indexed by World Wide  
Name and Index. The Index is the port number being interrogated. There may be  
different numbers of ports in each switch so the agent must determine the  
maximum allowable index on a switch by switch basis. An example of how to  
access one of these objects given a WWN of 100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.connSet.connUnitPortTable.connUnitPortEntry.connUnitPortUni  
tId.16.0.0.192.221.0.144.167.0.0.0.0.0.0.0.0.1".  
connUnitPortUnitId (1.3.6.1.3.94.1.10.1.1)  
The connUnitId of the connectivity unit that contains this port.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the World Wide Name of the switch followed by 8 bytes of zeros.  
For example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitPortIndex (1.3.6.1.3.94.1.10.1.2)  
A unique value among all connUnitPortEntrys on this connectivity unit, between 1  
and connUnitNumPort[connUnitPortUnitId].  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
The index for each port on the switch. SANbox 5200/5600 Series = 1 -  
8,12,16,20 (varies depending on number of licensed ports)  
59047-09 C  
5-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Table  
S
connUnitPortType (1.3.6.1.3.94.1.10.1.3)  
The port type.  
Syntax  
INTEGER {  
unknown(1),  
other(2),  
not-present(3),  
hub-port(4),  
n-port(5), - end port for fabric  
nl-port(6), - end port for loop  
fl-port(7), - public loop  
f-port(8), - fabric port  
e-port(9), - fabric expansion port  
g-port(10), - generic fabric port  
domain-ctl(11), - domain controller  
hub-controller(12),  
scsi(13), - parallel SCSI port  
escon(14),  
lan(15),  
wan(16),  
ac(17), - AC power line  
dc(18), - DC power line  
ssa(19) - serial storage architecture  
wdm(20),-- optical wave division multiplex  
ib 21), - Infiniband  
ipstore(22) - IP storage  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-20 for connUnitPortType return values.  
Table 5-20. ConnUnitPortType Return Values  
Switch Port Type  
Return Value  
G
g-port (10)  
5-32  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Port Table  
A
Table 5-20. ConnUnitPortType Return Values  
Switch Port Type Return Value  
FL  
fl-port (7)  
f-port (8)  
F
E
e-port (9)  
other (2)  
Donor  
other  
unknown (1)  
connUnitPortFCClassCap (1.3.6.1.3.94.1.10.1.4)  
Bit mask that specifies the classes of service capability of this port. If this is not  
applicable, return all bits set to zero.  
The bits have the following definition:  
unknown - 0  
class-f - 1  
class-one - 2  
class-two - 4  
class-three - 8  
class-four - 16  
class-five - 32  
class-six - 64  
Syntax  
OCTET STRING (SIZE (2))  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns 0x0d (Class f, Class 2, and Class 3).  
59047-09 C  
5-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Port Table  
S
connUnitPortFCClassOp (1.3.6.1.3.94.1.10.1.5)  
Bit mask that specifies the classes of service that are currently operational. If this  
is not applicable, return all bits set to zero. This object has the same definition as  
connUnitPortFCClassCap" ::= { connUnitPortEntry 5 }.  
Syntax  
OCTET STRING (SIZE (2))  
Access  
read-only  
Status  
mandatory  
Return Value  
If F or FL, returns 0x0c (Class 2, and Class 3), else returns 0x0d (Class f,  
Class 2, and Class 3).  
connUnitPortState (1.3.6.1.3.94.1.10.1.6)  
The user selected state of the port hardware.  
Syntax  
INTEGER {  
unknown(1),  
online(2), - available for meaningful work  
offline(3), - not available for meaningful work  
bypassed(4), - no longer used (4/12/00)  
diagnostics(5)  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-21 for connUnitPortState return values.  
5-34  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Table  
A
Table 5-21. ConnUnitPortState Return Values  
Port Value Return Value  
Online  
online (2)  
offline (3)  
offline (3)  
Offline  
Downed  
Diagnostics  
other  
diagnostics (5)  
unknown (1)  
connUnitPortStatus (1.3.6.1.3.94.1.10.1.7)  
An overall protocol status for the port. This value of connUnitPortState is not  
online, then this is reported Unknown.  
Syntax  
INTEGER {  
unknown(1),  
unused(2), - device cannot report this status  
ready(3), - FCAL Loop or FCPH Link reset protocol; initialization complete  
warning(4), - do not use (4/12/00)  
failure(5), - do not use (4/12/00)  
notparticipating(6), - loop not participating and does not have a loop address  
initializing(7), - protocol is proceeding  
bypass(8), - do not use (4/12/00)  
ols(9) - FCP offline status  
other(10) - status not described above  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns unused (2).  
connUnitPortTransmitterType (1.3.6.1.3.94.1.10.1.8)  
The technology of the port transceiver.  
Syntax  
INTEGER {  
59047-09 C  
5-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Port Table  
S
unknown(1),  
other(2),  
unused(3),  
shortwave(4),  
longwave(5),  
copper(6),  
scsi(7),  
longwaveNoOFC(8),  
shortwaveNoOFC(9),  
longwaveLED(10),  
ssa(11)  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-22 for connUnitPortTransmitterType return values.  
Table 5-22. ConnUnitPortTransmitterType Return Values  
SFP Transmitter Type Return Value  
Not Installed  
Unused (3)  
SL  
Shortwave (4)  
Longwave (5)  
LL  
LC  
LongwaveNoOFC (8)  
ShortwaveNoOFC (9)  
Copper (6)  
SN  
EL  
Other  
Unknown (1)  
connUnitPortModuleType (1.3.6.1.3.94.1.10.1.9)  
The module type of the port connector.  
Syntax  
INTEGER {  
unknown(1),  
other(2),  
5-36  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Port Table  
A
gbic(3),  
embedded(4), - fixed (oneXnine)  
glm(5),  
gbicSerialId(6),  
gbicNoSerialId(7),  
gbicNotInstalled(8),  
smallFormFactor(9) - this is generically a small form factor connector.  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-23 for connUnitPortModuleType return values.  
Table 5-23. ConnUnitPortModuleType Return Values  
Type Value  
1 Gb/2Gb Ports  
10 Gb Ports  
smallFormFactor(9)  
Other (2)  
connUnitPortWwn (1.3.6.1.3.94.1.10.1.10)  
The World Wide Name of the port, if applicable, otherwise returns all zeros.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the Port World Wide Name followed by 8 bytes of zeros. For  
example, the return value for port #2 would be 20 02 00 C0 DD 00 71 C9 00  
00 00 00 00 00 00 00, and the return value for port #2 would be 20 0E 00 C0  
DD 00 71 C9 00 00 00 00 00 00 00 00. If a port is configured as a Donor,  
return value = 0.  
59047-09 C  
5-37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Port Table  
S
connUnitPortFCId (1.3.6.1.3.94.1.10.1.11)  
This is the assigned Fibre Channel ID of this port. This value is expected to be a  
Big Endian value of 24 bits. If this is a loop, then it is the ALPA that is connected. If  
this is an E_Port, then it will only contain the domain ID left justified, zero filled. If  
this port does not have a Fibre Channel address, returns all bits set to 1.  
Syntax  
FcAddressId  
Access  
read-only  
Status  
mandatory  
Return Value  
The address for each port based on Domain, Area, and ALPA. For example,  
port #15 would be equal to 640F00 (Domain = 0x64, Area = 0x0F, ALPA =  
0x00).  
connUnitPortSn (1.3.6.1.3.94.1.10.1.12)  
The serial number of the unit. If not applicable, returns an empty string.  
Syntax  
DisplayString (SIZE(0..79))  
Access  
read-only  
Status  
unsupported  
Return Value  
Return Value = The media part number of the SFP (or MediaPartNumber) if  
installed.  
connUnitPortRevision (1.3.6.1.3.94.1.10.1.13)  
The port revision. For example, for a GBIC.  
Syntax  
DisplayString (SIZE(0..79))  
5-38  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Table  
A
Access  
read-only  
Status  
unsupported  
Return Value  
Return Value = The media revision of the SFP (or MediaRevision) if  
installed.  
connUnitPortVendor (1.3.6.1.3.94.1.10.1.14)  
The port vendor. For example, for a GBIC.  
Syntax  
DisplayString (SIZE(0..79))  
Access  
read-only  
Status  
unsupported  
Return Value  
The port vendor as reported by the SFP (if supported).  
connUnitPortSpeed (1.3.6.1.3.94.1.10.1.15)  
The speed of the port in kilobytes per second.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The operational speed, otherwise returns the administrative speed setting. If  
1 Gbps, returns 106250. If 2 Gbps, returns 212500. If 4 Gbps, returns  
425000. If 10 Gbps, returns 1062500.  
59047-09 C  
5-39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Port Table  
S
connUnitPortControl (1.3.6.1.3.94.1.10.1.16)  
This object is used to control the addressed connUnit's port.  
resetConnUnitPort: If the addressed connUnit allows this operation to be  
performed to this port, the addressed port performs a vendor-specific ”reset”  
operation. Examples of these operations are: the Link Reset protocol, the  
Loop Initialization protocol, or a re-synchronization occurring between the  
transceiver in the addressed port to the transceiver that the port is  
connected to.  
bypassConnUnitPort: If the addressed connUnit allows this operation to be  
performed to this port, the addressed port performs a vendor-specific  
“bypass” operation. Examples of these operations are transitioning from  
online to offline, a request (non-participating) command to the Loop Port  
state machine, or removal of the port from an arbitrated loop by a hub.  
unbypassConnUnitPort: If the addressed connUnit allows this operation to  
be performed to this port, the addressed port performs a vendor-specific  
“unbypass” operation. Examples of these operations are the Link Failure  
protocol, a request (participating) command to the Loop Port state machine,  
or addition of the port to an arbitrated loop by a hub.  
offlineConnUnitPort: If the addressed connUnit allows this operation to be  
performed to this port, the addressed port performs a vendor-specific  
“offline” operation. Examples of these operations are disabling a port's  
transceiver, the Link Failure protocol, request (non-participating) command  
to the Loop Port state machine, or removal of the port from an arbitrated  
loop by a hub.  
onlineConnUnitPort: If the addressed connUnit allows this operation to be  
performed to this port, the addressed port performs a vendor-specific  
“online” operation. Examples of these operations are enabling a port's  
transceiver, the Link Failure protocol, request (participating) command to the  
Loop Port state machine, or addition of the port from an arbitrated loop by a  
hub.  
resetConnUnitPortCounters: If the addressed connUnit allows this  
operation to be performed to this port, the addressed port statistics table  
counters will be set to zero.  
Each implementation may choose not to allow any or all of these values on a SET.  
On a read, if you do not support write, then return invalid. Otherwise, return the  
last control operation attempted.  
Syntax  
INTEGER {  
unknown(1),  
invalid(2),  
resetConnUnitPort(3),  
5-40  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Port Table  
A
bypassConnUnitPort(4),  
unbypassConnUnitPort(5),  
offlineConnUnitPort(6),  
onlineConnUnitPort(7),  
resetConnUnitPortCounters(8)  
}
Access  
read-write  
Status  
mandatory  
Return Value  
Refer to Table 5-24 for connUnitPortControl read return values.  
Table 5-24. ConnUnitPortControl Read Return Values  
Port Value Return Value  
Online  
online (7)  
offline (6)  
offline (6)  
unknown (1)  
Offline  
Diagnostics  
other  
Refer to Table 5-25 for connUnitPortControl write command values.  
Table 5-25. ConnUnitPortControl Write Command Values  
Control Value  
Command Sent  
Online (7)  
Offline (6)  
online  
offline  
ResetCounters (8)  
other  
clear counters  
error returned  
connUnitPortName (1.3.6.1.3.94.1.10.1.17)  
A user-defined name for this port. This means that up to DisplayString characters  
may be supported. If less than, then the name will be truncated in the connunit.  
59047-09 C  
5-41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Table  
S
Syntax  
INTEGER  
Access  
read-write  
Status  
mandatory  
Return Value  
The symbolic port name. A 1G or 2G only capable port, would return port  
followed by the port number. 10G ports would return 10G followed by the  
port number. For example, a 1G/2G port#2 would return 'Port2' and a 10G  
port#18 would return '10G-18' by default.  
connUnitPortPhysicalNumber (1.3.6.1.3.94.1.10.1.18)  
This is the internal port number this port is known by. In many implementations,  
this should be the same as connUnitPortIndex. Some implementations may have  
an internal port representation not compatible with the rules for table indexes. In  
that case, provide the internal representation of this port in this object. This value  
may also be used in the connUnitLinkPortNumberX or connUnitLinkPortNumberY  
objects of the connUnitLinkTable.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The physical port number.  
connUnitPortStatObject (1.3.6.1.3.94.1.10.1.19)  
This contains the OID of the first object of the table that contains the statistics for  
this particular port. If this has a value of zero, then there are no statistics available  
for this port. The port type information will help identify the statistics objects that  
will be found in the table.  
Syntax  
OBJECT IDENTIFIER  
5-42  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Table  
A
Access  
read-only  
Status  
deprecated  
Return Value  
The port object ID (1.2.6.1.3.94.4.5.1.1).  
connUnitPortProtocolCap (1.3.6.1.3.94.1.10.1.20)  
Bit mask that specifies the driver level protocol capability of this port. If this is not  
applicable, returns all bits set to zero.  
The bits have the following definitions:  
unknown - 0  
Loop - 1  
Fabric - 2  
SCSI - 4  
TCP/IP - 8  
VI - 16  
FICON - 32  
Syntax  
OCTET STRING (SIZE (2))  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns 0x03 (Loop, Fabric).  
connUnitPortProtocolOp (1.3.6.1.3.94.1.10.1.21)  
Bit mask that specifies the driver level protocol(s) that are currently operational. If  
not applicable, return all bits set to zero. This object has the same definition as  
connUnitPortProtocolCap.  
Syntax  
OCTET STRING (SIZE (2))  
59047-09 C  
5-43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Table  
S
Access  
read-only  
Status  
unsupported  
Return Value  
Always returns error status "NoSuchName".  
connUnitPortNodeWwn (1.3.6.1.3.94.1.10.1.22)  
The Node World Wide Name of the port if applicable, otherwise all zeros. This  
should have the same value for a group of related ports. The container is defined  
as the largest physical entity. For example, all ports on HBAs on a host will have  
the same Node WWN. All ports on the same storage subsystem will have the  
same Node WWN." ::= { connUnitPortEntry 22 }.  
Syntax  
FcNameId  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the World Wide Node Name of the switch. For example: 10 00 00  
C0 DD 00 71 C9.  
connUnitPortHWState (1.3.6.1.3.94.1.10.1.23)  
The hardware detected state of the port.  
Syntax  
INTEGER {  
unknown(1),  
failed(2), - port failed diagnostics  
bypassed(3), - FCAL bypass, loop only  
active(4), - connected to a device  
loopback(5), - Port in external loopback  
txfault(6), - Transmitter fault  
noMedia(7), - media not installed linkDown  
(8) - waiting for activity (rx sync)  
}
5-44  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Event Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
Refer to Table 5-26 for connUnitPortHWState port state return values.  
Table 5-26. ConnUnitPortHWState Port State Return Values  
Port State  
Return Value  
If DiagStatus = Failed  
Failed (2)  
If SFP = Not Installed  
If SyncStatus = SyncAcquired  
If SyncStatus = SyncLost  
Other  
NoMedia (7)  
Active (4)  
LinkDown (8)  
Unknown (1)  
Event Table  
The objects described in this section are in a table format indexed by World Wide  
Name and Index. The maximum index is determined based on the number of  
events in the table. An example of how to access one of these objects given a  
WWN of 100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.connSet.connUnitEventTable.connUnitEventEntry.connUnitEvent  
UnitId.16.0.0.192.221.0.144.167.0.0.0.0.0.0.0.0.1".  
connUnitEventUnitId (1.3.6.1.3.94.1.11.1.1)  
The connUnitId of the connectivity unit that contains this event table.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Event Table  
S
Return Value  
The World Wide Name of the switch followed by 8 bytes of zeros. For  
example, 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitEventIndex (1.3.6.1.3.94.1.11.1.2)  
Each connectivity unit has its own event buffer. As it wraps, it may write over  
previous events. This object is an index into the buffer. It is recommended that this  
table be read using getNext's to retrieve the initial table. The management  
application should read the event table at periodic intervals and then determine if  
any new entries were added by comparing the last known index value with the  
current highest index value. The management application should then update its  
copy of the event table. If the read interval is too long, it is possible that there may  
be events that may not be contained in the agent's internal event buffer. For  
example, an agent may read events 50-75. At the next read interval,  
connUnitEventCurrID is 189. If the management application tries to read event  
index 76, and the agent's internal buffer is 100 entries max, event index 76 will no  
longer be available.  
The index value is an incrementing integer starting from one every time there is a  
table reset. On table reset, all contents are emptied and all indexes are set to  
zero. When an event is added to the table, the event is assigned the next higher  
integer value than the last item entered into the table. If the index value reaches  
its maximum value, the next item entered will cause the index value to roll over  
and start at one again.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
The table index.  
5-46  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Event Table  
A
connUnitEventId (1.3.6.1.3.94.1.11.1.3)  
The internal event ID. Incremented for each event, ranging between 1 and  
connUnitMaxEvents. Not used as table index to simplify the agent  
implementation. When this reaches the end of the range specified by  
connUnitMaxEvents, the ID will roll over to start at one. This value will be set back  
to one at reset. The relationship of this value to the index is that internal event ID  
may represent a smaller number than a 32 bit integer (for example, maximum 100  
entries) and would only have a value range up to connUnitMaxEvents.  
Syntax  
INTEGER  
Access  
read-only  
Status  
deprecated  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
connUnitREventTime (1.3.6.1.3.94.1.11.1.4)  
The real time when the event occurred. It has the following format.  
DDMMYYYY HHMMSS  
DD=day number  
MM=month number  
YYYY=year number  
HH=hour number  
MM=minute number  
SS=seconds number  
If not applicable, return either a NULL string or “00000000 000000”.  
Syntax  
DisplayString (SIZE (0..15))  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Event Table  
S
Return Value  
The timestamp of the event.  
connUnitSEventTime (1.3.6.1.3.94.1.11.1.5)  
This is the sysUpTime timestamp when the event occurred.  
Syntax  
connUnitSEventTime  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns error status "NoSuchName".  
connUnitEventSeverity (1.3.6.1.3.94.1.11.1.6)  
The event severity level.  
Syntax  
FcEventSeverity  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns error status "NoSuchName".  
connUnitEventType (1.3.6.1.3.94.1.11.1.7)  
The type of this event.  
Syntax  
INTEGER {  
unknown(1),  
other(2),  
status(3),  
configuration(4),  
5-48  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Event Table  
A
topology(5)  
}
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns 3 (Status).  
connUnitEventObject (1.3.6.1.3.94.1.11.1.8)  
This is used with the connUnitEventType to identify which object the event refers  
to. Examples include connUnitPortStatus.connUnitId.connUnitPortIndex and  
connUnitStatus.connUnitId.  
Syntax  
OBJECT IDENTIFIER  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns error status "NoSuchName".  
connUnitEventDescr (1.3.6.1.3.94.1.11.1.9)  
The description of the event.  
Syntax  
DisplayString  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Link Table  
S
Return Value  
The event description in the form:  
"[Id][timestamp][severity][module][Description]"  
Link Table  
The objects described in this section are in a table format indexed by World Wide  
Name and Index. The index is an index into the link table for the switch. There  
may be as many link entries as there are ports. An example of how to access one  
of these objects given a WWN of 100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.connSet.connUnitLinkTable.connUnitLinkEntry.connUnitLinkUni  
tId.16.0.0.192.221.0.144.167.0.0.0.0.0.0.0.0.1".  
If the agent is able to discover links which do not directly attach to members of its  
agency and its discovery algorithm gives some assurance the links are recently  
valid, it may include these links. Link information entered by administrative action  
may be included even if not validated directly if the link has at least one endpoint  
in this agency, but should not be included otherwise.  
A connectivity unit should fill the table in as best it can. One of the methods to fill  
this in would be to use the RNID ELS (ANSI document 99-422v0). This allows one  
to query a port for the information needed for the link table.  
This table is accessed either directly if the management software has an index  
value or via GetNexts. The value of the indexes are not required to be contiguous.  
Each entry created in this table will be assigned an index. This relationship is kept  
persistent until the entry is removed from the table or the system is reset. The total  
number of entries are defined by the size of the table  
connUnitLinkUnitId (1.3.6.1.3.94.1.12.1.1)  
The connUnitId of the connectivity unit that contains this link table.  
Syntax  
connUnitLinkUnitId  
Access  
read-only  
Status  
mandatory  
Return Value  
The World Wide Name of the switch followed by 8 bytes of zeros. For  
example, 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
5-50  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Link Table  
A
connUnitLinkIndex (1.3.6.1.3.94.1.12.1.2)  
This index is used to create a unique value for each entry in the link table with the  
same connUnitLinkUnitId. The value can only be reused if it is not currently in use  
and the value is the next candidate to be used. This value wraps at the highest  
value represented by the size of INTEGER. This value is reset to zero when the  
system is reset, and the first value to be used is one.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
The table index.  
connUnitLinkNodeIdX (1.3.6.1.3.94.1.12.1.3)  
The Node WWN of the unit at one end of the link. If the Node WWN is unknown  
and the Node is a connUnit in the responding agent, then the value of this object  
must be equal to its connUnitID.  
Syntax  
OCTET STRING (SIZE(16))  
Access  
read-only  
Status  
mandatory  
Return Value  
The World Wide Name of the local switch for each entry in the link table. For  
example, 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitLinkPortNumberX (1.3.6.1.3.94.1.12.1.4)  
The port number on the unit specified by connUnitLinkNodeIdX if known,  
otherwise -1. If the value is non-negative, then it will be equal to  
connUnitPortPhysicalNumber.  
59047-09 C  
5-51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Link Table  
S
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
The local port number for each entry in the link table.  
connUnitLinkPortWwnX (1.3.6.1.3.94.1.12.1.5)  
The port WWN of the unit specified by connUnitLinkNodeIdX if known, otherwise  
16 octets of binary 0" ::= { connUnitLinkEntry 5 }.  
Syntax  
connUnitLinkPortWwnX  
Access  
read-only  
Status  
mandatory  
Return Value  
The local World Wide port number for each entry in the link table.  
connUnitLinkNodeIdY (1.3.6.1.3.94.1.12.1.6)  
The Node WWN of the unit at the other end of the link. If the Node WWN is  
unknown and the Node is a connUnit in the responding SNMP agency, then the  
value of this object must be equal to its connUnitID.  
Syntax  
OCTET STRING (SIZE(16))  
Access  
read-only  
Status  
mandatory  
5-52  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Link Table  
A
Return Value  
The remote World Wide Node number for each entry in the link table.  
connUnitLinkPortNumberY (1.3.6.1.3.94.1.12.1.7)  
The port number on the unit specified by connUnitLinkNodeIdY if known,  
otherwise -1. If the value is non-negative, then it will be equal to  
connUnitPortPhysicalNumber.  
Syntax  
OCTET STRING (SIZE(16))  
Access  
read-only  
Status  
mandatory  
Return Value  
The remote port number for inter-switch link, if known. Otherwise, -1  
(0xFFFFFFFF).  
connUnitLinkPortWwnY (1.3.6.1.3.94.1.12.1.8)  
The port WWN on the unit specified by connUnitLinkNodeIdY if known, otherwise  
16 octets of binary 0" ::= { connUnitLinkEntry 8 }.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
The remote Port World Wide Name for each entry in the link table, if known.  
connUnitLinkAgentAddressY (1.3.6.1.3.94.1.12.1.9)  
The address of an FCMGMT MIB agent for the Node identified by  
connUnitLinkNodeIdY, if known. Otherwise 16 octets of binary 0" ::=  
{connUnitLinkEntry 9}.  
59047-09 C  
5-53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Link Table  
S
Syntax  
OCTET STRING (SIZE(16))  
Access  
read-only  
Status  
mandatory  
Return Value  
The remote IP address of the remote switch, if known. Otherwise, returns  
sixteen zeroes.  
connUnitLinkAgentAddressTypeY (1.3.6.1.3.94.1.12.1.10)  
If connUnitLinkAgentAddressY is nonzero, it is a protocol address.  
ConnUnitLinkAgentAddressTypeY is the “address family number” assigned by  
IANA to identify the address format.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns 1 (Ipv4).  
connUnitLinkAgentPortY (1.3.6.1.3.94.1.12.1.11)  
The IP port number for the agent. This is provided in case the agent is at a  
non-standard SNMP port.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
5-54  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Link Table  
A
Return Value  
Returns value of 0.  
connUnitLinkUnitTypeY (1.3.6.1.3.94.1.12.1.12)  
Type of the Fibre Channel connectivity unit as defined in connUnitType.  
Syntax  
FcUnitType  
Access  
read-only  
Status  
mandatory  
Return Value  
The type of remote device in the link table. For example, switch (4).  
connUnitLinkConnIdY (1.3.6.1.3.94.1.12.1.13  
This is the Fibre Channel ID of this port. If the connectivity unit is a switch, this is  
expected to be a Big Endian value of 24 bits. If this is loop, then it is the ALPA that  
is connected. If this is an E_Port, then it will only contain the domain ID. If not any  
of those, unknown or cascaded loop, returns all bits set to 1.  
Syntax  
OCTET STRING (SIZE(3))  
Access  
read-only  
Status  
mandatory  
Return Value  
The remote Fibre Channel address of each entry in the link table.  
connUnitLinkCurrIndex (1.3.6.1.3.94.1.12.1.14)  
The last used link index.  
Syntax  
INTEGER  
59047-09 C  
5-55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Zone Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
The last used link table index number.  
Zone Table  
The objects described in this section are in a table format indexed Zone number  
and Index. The zones are numbered 1 to connUnitZoneSetNumZones, the index  
represents the members within the zones.  
An example of how to access one of these objects:  
fcmgmt.connSet.connUnitZoneTable.connUnitZoneEntry.connUnitZoneIndex.1.1  
connUnitZoneIndex (1.3.6.1.3.94.1.13.1.1)  
Unique table index for each zone. Valid values are between 1 and  
connUnitZoneSetNumZones.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns index number for each zone within the active zoneset.  
connUnitZoneMemberIndex (1.3.6.1.3.94.1.13.1.2)  
Unique table index for each zone member. Valid values are between 1 and  
connUnitZoneNumMembers.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
5-56  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Zone Table  
A
Status  
mandatory  
Return Value  
Returns index number for each member within a zone.  
connUnitZoneSetName (1.3.6.1.3.94.1.13.1.3)  
Name of the active zone set to which the zone and zone member belong.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the zone set name.  
connUnitZoneSetNumZones (1.3.6.1.3.94.1.13.1.4)  
The number of zones in the active zone set.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the number of zones within the active zoneset.  
connUnitZoneName (1.3.6.1.3.94.1.13.1.5)  
Name of the zone.  
Syntax  
DisplayString (SIZE (0..79))  
59047-09 C  
5-57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Zone Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the name of the zone.  
connUnitZoneCapabilities (1.3.6.1.3.94.1.13.1.6)  
1-byte bit mask that specifies the zoning capabilities supported by the fabric.  
Bit 7 - Soft zones supported.  
Bit 6 - Hard zones supported.  
Bits 5-0 - Reserved.  
Syntax  
OCTET STRING (SIZE(1))  
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns 0xC0.  
connUnitZoneEnforcementState (1.3.6.1.3.94.1.13.1.7)  
1-byte bit mask that specifies the current enforcement of the Zone Set.  
Bit 7 - Soft zone set enforced.  
Bit 6 - Hard zone set enforced.  
Bits 5-0 - Reserved.  
Syntax  
OCTET STRING (SIZE(1))  
Access  
read-only  
5-58  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Zone Table  
A
Status  
mandatory  
Return Value  
Returns the zone type. Mapped as follows:  
Soft.......0x80  
Hard......0x40  
connUnitZoneAttributeBlock (1.3.6.1.3.94.1.13.1.8)  
A variable length structure that contains extended zone attributes defined in the  
FC-GS-4 enhanced zone server. See FC-GS-4 draft standard for details and  
format of the structure. Support of this object is optional.  
Syntax  
OCTET STRING (SIZE(80))  
Access  
read-only  
Status  
mandatory  
Return Value  
Not supported. Always returns SNMP error NoSuchName.  
connUnitZoneNumMembers (1.3.6.1.3.94.1.13.1.9)  
Number of zone members in the zone: connUnitZoneName.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns total number of members in a zone.  
59047-09 C  
5-59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Zone Table  
S
connUnitZoneMemberIdType (1.3.6.1.3.94.1.13.1.10)  
Type of zone member ID:  
1- Port WWN  
2- Domain & Port ID  
3- FC Address  
4- Node WWN  
5- Alias Name  
6-'FF'h - Vendor specified.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Retrieves the member ID type.  
WWN...............0x01 // Port WWN  
Domain/Port....0x02 // Domain & Port ID  
FCaddress.......0x03 // FC Address  
[other]................0xff // Vendor specific  
connUnitZoneMemberID (1.3.6.1.3.94.1.13.1.11)  
ID of the zone member based on connUnitZoneMemberIdType.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the zone member name as a 16 8-bit octets. Mapped as follows:  
5-60  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Zoning Alias Table  
A
WWN member - WWN (8 bytes) followed by 8 bytes of zeros.  
FC address - FC address (3 bytes) followed by 13 bytes of zeros.  
Domain/Port - Domain/Port address (2 bytes) followed by 14 bytes of zeros.  
Zoning Alias Table  
The objects described in this section are in a table format indexed by Alias  
Number and Index. The aliases are numbered 1 to  
connUnitZoningAliasNumAliases, the index represents the members within the  
alias. An example of how to access one of these objects:  
"fcmgmt.connSet.connUnitZoneTable.connUnitZoneEntry.connUnitZoningAliasIn  
dex.1.1"  
connUnitZoningAliasIndex (1.3.6.1.3.94.1.14.1.1)  
Unique table index for each alias. Valid values are between 1 and  
connUnitZoningAliasNumAliases.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the alias index.  
connUnitZoningAliasMemberIndex (1.3.6.1.3.94.1.14.1.2)  
Unique table index for each alias member. Valid values are between 1 and  
connUnitZoningAliasNumMembers.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Zoning Alias Table  
S
Return Value  
Returns the alias member index.  
connUnitZoningAliasNumAliases (1.3.6.1.3.94.1.14.1.3)  
The number of aliases defined in this table.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns number of aliases defined.  
connUnitZoningAliasName (1.3.6.1.3.94.1.14.1.4)  
The alias name.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns Alias name.  
connUnitZoningAliasNumMembers (1.3.6.1.3.94.1.14.1.5)  
Number of members in the alias: connUnitZoningAliasName.  
Syntax  
INTEGER  
Access  
read-only  
5-62  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Zoning Alias Table  
A
Status  
mandatory  
Return Value  
Returns number of members in a defined Alias zone.  
connUnitZoningAliasMemberIdType (1.3.6.1.3.94.1.14.1.6)  
Type of alias member ID:  
1- Port WWN  
2- Domain & Port ID  
3- FC Address  
Others: reserved.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the alias member Id type. Mapped as follows:  
WWN................. 0x01 // Port WWN  
DomainPort........ 0x02 // Domain & Port ID  
FC Address........ 0x03 // FC Address  
[other]................ 0xff // Vendor specific  
connUnitZoningAliasMemberID (1.3.6.1.3.94.1.14.1.7)  
ID of the alias member based on connUnitZoningAliasMemberIdType.  
Syntax  
FcGlobalId  
Access  
read-only  
59047-09 C  
5-63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Status  
mandatory  
Return Value  
Returns the alias zone member name as 16 8-bit octets. Mapped as follows:  
WWN member - WWN (8 bytes) followed by 8 bytes of zeros.  
FC address - FC address (3 bytes) followed by 13 bytes of zeros.  
Domain/Port - Domain/Port address (2 bytes) followed by 14 bytes of zeros.  
Port Statistics Table  
The objects described in this section are in a table format indexed by World Wide  
Name and Index. The index represents the port number to interrogate. An  
example of how to access one of these objects given a WWN of  
100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.statSet.connUnitPortStatTable.connUnitPortStatEntry.connUni  
tPortStatUnitId.16.0.0.192.221.0.144.167.0.0.0.0.0.0.0.0.1".  
There is one and only one statistics table for each individual port. For all objects in  
statistics table, if the object is not supported by the conn unit then the high order  
bit is set to 1 with all other bits set to zero. The high order bit is reserved to  
indicate if the object if supported or not. All objects start at a value of zero at  
hardware initialization and continue incrementing till end of 63 bits and then wrap  
to zero.  
connUnitPortStatUnitId (1.3.6.1.3.94.4.5.1.1)  
A unique value among all entries in this table having the same  
connUnitPortStatUnitId, between 1 and connUnitNumPort  
[connUnitPortStatUnitId].  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
mandatory  
5-64  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
Return Value  
Returns the World Wide Name of the switch followed by 8 bytes of zeros.  
For example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitPortStatIndex (1.3.6.1.3.94.4.5.1.2)  
A unique value among all entries in this table, between 0 and  
connUnitNumPort[connUnitPortUnitId].  
Syntax  
INTEGER (0..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
The port table index.  
connUnitPortStatCountError (1.3.6.1.3.94.4.5.1.3)  
A count of the errors that have occurred on this port.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
A hexidecimal value indicating the total number of errors for a port.  
connUnitPortStatCountTxObjects (1.3.6.1.3.94.4.5.1.4)  
The number of frames/packets/IOs/etc transmitted by this port. A Fibre Channel  
frame starts with SOF and ends with EOF. Fibre Channel loop devices should not  
count frames passed through. This value represents the sum total for all other Tx  
objects.  
Syntax  
OCTET STRING (SIZE (8))  
59047-09 C  
5-65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
A hexidecimal value indicating the total number of bytes transmitted by a  
port.  
connUnitPortStatCountRxObjects (1.3.6.1.3.94.4.5.1.5)  
The number of frames/packets/IOs/etc received by this port. A Fibre Channel  
frame starts with SOF and ends with EOF. Fibre Channel loop devices should not  
count frames passed through. This value represents the sum total for all other Rx  
objects.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
A hexidecimal value indicating the total number of bytes received by a port.  
connUnitPortStatCountTxElements (1.3.6.1.3.94.4.5.1.6)  
The number of octets or bytes that have been transmitted by this port. One  
second periodic polling of the port. This value is saved and compared with the  
next polled value to compute net throughput. For Fibre Channel, ordered sets are  
not included in the count.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
5-66  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
Return Value  
A hexidecimal value indicating the total number of bytes transmitted by a  
port.  
connUnitPortStatCountRxElements (1.3.6.1.3.94.4.5.1.7)  
The number of octets or bytes that have been received by this port. One second  
periodic polling of the port. This value is saved and compared with the next polled  
value to compute net throughput. For Fibre Channel, ordered sets are not  
included in the count.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
A hexidecimal value indicating the total number of bytes received by a port.  
connUnitPortStatCountBBCreditZero (1.3.6.1.3.94.4.5.1.8)  
Count of transitions in/out of BBcredit zero state. The other side is not providing  
any credit. This is a Fibre Channel statistic only.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountInputBuffersFull (1.3.6.1.3.94.4.5.1.9)  
Count of occurrences when all input buffers of a port were full and outbound  
buffer-to-buffer credit transitioned to zero. There is no credit to provide to other  
side. This is a Fibre Channel statistic only.  
59047-09 C  
5-67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountFBSYFrames (1.3.6.1.3.94.4.5.1.10)  
Count of times that FBSY was returned to this port as a result of a frame that  
could not be delivered to the other end of the link. This occurs if either the fabric or  
the destination port is temporarily busy. Port can only occur on SOFc1 frames (the  
frames that establish a connection). This is a Fibre Channel-only statistic. This is  
the sum of all classes. If you cannot keep the by-class counters, then keep the  
sum counters.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
A hexidecimal number indicating the total number of FBusy on a port.  
connUnitPortStatCountPBSYFrames (1.3.6.1.3.94.4.5.1.11)  
Count of times that PBSY was returned to this port as a result of a frame that  
could not be delivered to the other end of the link. This occurs if the destination  
port is temporarily busy. PBSY can only occur on SOFc1 frames (the frames that  
establish a connection). This is a Fibre Channel-only statistic. This is the sum of  
all classes. If you cannot keep the by-class counters, then keep the sum counters.  
Syntax  
OCTET STRING (SIZE (8))  
5-68  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit set to 1 with remaining bits set to  
zero.  
connUnitPortStatCountFRJTFrames (1.3.6.1.3.94.4.5.1.12)  
Count of times that FRJT was returned to this port as a result of a frame that was  
rejected by the fabric. This is the total for all classes and is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
A hexidecimal number indicating the total number of Frame Rejects on a  
port.  
connUnitPortStatCountPRJTFrames (1.3.6.1.3.94.4.5.1.13)  
Count of times that FRJT was returned to this port as a result of a frame that was  
rejected at the destination N_Port. This is the total for all classes and is a Fibre  
Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass1RxFrames (1.3.6.1.3.94.4.5.1.14)  
Count of Class 1 frames received at this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass1TxFrames (1.3.6.1.3.94.4.5.1.15)  
Count of Class 1 frames transmitted out this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass1FBSYFrames (1.3.6.1.3.94.4.5.1.16  
Count of times that FBSY was returned to this port as a result of a Class 1 frame  
that could not be delivered to the other end of the link. This occurs if either the  
fabric or the destination port is temporarily busy. FBSY can only occur on SOFc1  
frames (the frames that establish a connection). This is a Fibre Channel-only  
statistic.  
5-70  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass1PBSYFrames (1.3.6.1.3.94.4.5.1.17)  
Count of times that PBSY was returned to this port as a result of a Class 1 frame  
that could not be delivered to the other end of the link. This occurs if the  
destination N_Port is temporarily busy. PBSY can only occur on SOFc1 frames  
(the frames that establish a connection). This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass1FRJTFrames (1.3.6.1.3.94.4.5.1.18  
Count of times that FRJT was returned to this port as a result of a Class 1 frame  
that was rejected by the fabric. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass1PRJTFrames (1.3.6.1.3.94.4.5.1.19)  
Count of times that FRJT was returned to this port as a result of a Class 1 frame  
that was rejected at the destination N_Port. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass2RxFrames (1.3.6.1.3.94.4.5.1.20)  
Count of Class 2 frames received at this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of Class 2 frames received by a port.  
connUnitPortStatCountClass2TxFrames (1.3.6.1.3.94.4.5.1.21)  
Count of Class 2 frames transmitted out this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
5-72  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of Class 2 frames transmitted by a port.  
connUnitPortStatCountClass2FBSYFrames (1.3.6.1.3.94.4.5.1.22)  
Count of times that FBSY was returned to this port as a result of a Class 2 frame  
that could not be delivered to the other end of the link. This occurs if either the  
fabric or the destination port is temporarily busy. FBSY can only occur on SOFc1  
frames (the frames that establish a connection). This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass2PBSYFrames (1.3.6.1.3.94.4.5.1.23)  
Count of times that PBSY was returned to this port as a result of a Class 2 frame  
that could not be delivered to the other end of the link. This occurs if the  
destination N_Port is temporarily busy. PBSY can only occur on SOFc1 frames  
(the frames that establish a connection). This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass2FRJTFrames (1.3.6.1.3.94.4.5.1.24)  
Count of times that FRJT was returned to this port as a result of a Class 2 frame  
that was rejected by the fabric. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass2PRJTFrames (1.3.6.1.3.94.4.5.1.25)  
Count of times that FRJT was returned to this port as a result of a Class 2 frame  
that was rejected at the destination N_Port. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountClass3RxFrames (1.3.6.1.3.94.4.5.1.26)  
Count of Class 3 frames received at this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
5-74  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of Class 3 frames received by a port.  
connUnitPortStatCountClass3TxFrames (1.3.6.1.3.94.4.5.1.27)  
Count of Class 3 frames transmitted out this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of Class 3 frames transmitted by a port.  
connUnitPortStatCountClass3Discards (1.3.6.1.3.94.4.5.1.28)  
Count of Class 3 frames that were discarded upon reception at this port. There is  
no FBSY or FRJT generated for Class 3 frames. They are simply discarded if they  
cannot be delivered. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of Class3Toss frames for a port.  
59047-09 C  
5-75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
connUnitPortStatCountRxMulticastObjects (1.3.6.1.3.94.4.5.1.29)  
Count of Multicast frames or packets received at this port.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountTxMulticastObjects (1.3.6.1.3.94.4.5.1.30)  
Count of Multicast frames or packets transmitted out this port.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountRxBroadcastObjects (1.3.6.1.3.94.4.5.1.31)  
Count of Broadcast frames or packets received at this port.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
5-76  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountTxBroadcastObjects (1.3.6.1.3.94.4.5.1.32)  
Count of Broadcast frames or packets transmitted out this port. On a Fibre  
Channel loop, count only OPNr frames generated.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountRxLinkResets (1.3.6.1.3.94.4.5.1.33)  
Count of link resets. This is the number of LRs received. This is a Fibre  
Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of RxLinkResets received by a port.  
connUnitPortStatCountTxLinkResets (1.3.6.1.3.94.4.5.1.34)  
Count of link resets. The number of LRs transmitted. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
59047-09 C  
5-77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of TxLinkResets transmitted by a port.  
connUnitPortStatCountNumberLinkResets (1.3.6.1.3.94.4.5.1.35)  
Count of link resets and LIPs detected at this port. The number of times the reset  
link protocol is initiated. These are the count of the logical resets, and a count of  
the number of primitives. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of TotalLinkResets for a port.  
connUnitPortStatCountRxOfflineSequences (1.3.6.1.3.94.4.5.1.36)  
Count of offline primitive OLSs received at this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of RxOfflineSeqs received by a port.  
5-78  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
connUnitPortStatCountTxOfflineSequences (1.3.6.1.3.94.4.5.1.37)  
Count of offline primitive OLSs transmitted by this port. This is a Fibre  
Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of TxOfflineSeqs transmitted by a port.  
connUnitPortStatCountNumberOfflineSequences (1.3.6.1.3.94.4.5.1.38)  
Count of offline primitive sequences received at this port. This is a Fibre  
Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of TotalOfflineSeqs received by a port.  
connUnitPortStatCountLinkFailures (1.3.6.1.3.94.4.5.1.39)  
Count of link failures. This count is part of the Link Error Status Block (LESB).  
(FC-PH 29.8). This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
59047-09 C  
5-79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Status  
mandatory  
Return Value  
The total number of LinkFailures for a port.  
connUnitPortStatCountInvalidCRC (1.3.6.1.3.94.4.5.1.40)  
Count of frames received with invalid CRC. This count is part of the Link Error  
Status Block (LESB). (FC-PH 29.8). Loop ports should not count CRC errors  
passing through when monitoring. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of InvalidCRCs received by a port.  
connUnitPortStatCountInvalidTxWords (1.3.6.1.3.94.4.5.1.41)  
Count of invalid transmission words received at this port. This count is part of the  
Link Error Status Block (LESB). (FC-PH 29.8). This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of DecodeErrors for a port.  
5-80  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
connUnitPortStatCountPrimitiveSequenceProtocolErrors  
(1.3.6.1.3.94.4.5.1.42)  
Count of primitive sequence protocol errors detected at this port. This count is part  
of the Link Error Status Block (LESB). (FC-PH 29.8). This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of PrimSeqErrors for a port.  
connUnitPortStatCountLossofSignal (1.3.6.1.3.94.4.5.1.43)  
Count of instances of signal loss detected at port. This count is part of the Link  
Error Status Block (LESB). (FC-PH 29.8). This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountLossofSynchronization (1.3.6.1.3.94.4.5.1.44)  
Count of instances of synchronization loss detected at port. This count is part of  
the Link Error Status Block (LESB). (FC-PH 29.8). This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
59047-09 C  
5-81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
The total number LossOfSyncs detected by this port.  
connUnitPortStatCountInvalidOrderedSets (1.3.6.1.3.94.4.5.1.45)  
Count of invalid ordered sets received at port. This count is part of the Link Error  
Status Block (LESB). (FC-PH 29.8). This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountFramesTooLong (1.3.6.1.3.94.4.5.1.46)  
Count of frames received at this port where the frame length was greater than  
what was agreed to in FLOGI/PLOGI. This could be caused by losing the end of  
frame delimiter. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
5-82  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Port Statistics Table  
A
connUnitPortStatCountFramesTruncated (1.3.6.1.3.94.4.5.1.47)  
Count of frames received at this port where the frame length was less than the  
minimum indicated by the frame header (normally 24 bytes). It could be more if  
the DFCTL field indicates an optional header should have been present. This is a  
Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountAddressErrors (1.3.6.1.3.94.4.5.1.48)  
Count of frames received with unknown addressing.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
The total number of InvalidDestAddr frames received by a port.  
connUnitPortStatCountDelimiterErrors (1.3.6.1.3.94.4.5.1.49)  
Count of invalid frame delimiters received at this port. An example is a frame with  
a Class 2 start and a Class 3 at the end. This is a Fibre Channel-only statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
59047-09 C  
5-83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Simple Name Server Table  
S
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
connUnitPortStatCountEncodingDisparityErrors (1.3.6.1.3.94.4.5.1.50)  
Count of disparity errors received at this port. This is a Fibre Channel-only  
statistic.  
Syntax  
OCTET STRING (SIZE (8))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns high order bit to 1 with all other bits set to zero.  
Simple Name Server Table  
The objects described in this section are in a table format indexed by World Wide  
Name and Index. The index represents the table index. An example of how to  
access one of these objects given a WWN of 100000c0dd0090a7 is:  
"snmpget localhost public  
fcmgmt.connUnitServiceSet.connUnitServiceTables.connUnitSnsTable.c  
onnUnitSnsEntry.connUnitSnsId.16.0.0.192.221.0.144.167.0.0.0.0.0.0  
.0.0.1".  
The Fibre Channel Simple Name Server table contains an entry for each device  
presently known to this connUnit. There will not be any version on this since  
FC-GS3 does not define a version today.  
This table is accessed either directly if the management software has an index  
value or using GetNexts. The value of the indexes are not required to be  
contiguous. Each entry created in this table will be assigned an index. This  
relationship is kept persistent until the entry is removed from the table or the  
system is reset. The total number of entries are defined by the size of the table.  
5-84  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Simple Name Server Table  
A
connUnitSnsMaxEntry (1.3.6.1.3.94.5.1.1)  
The current number of entries in the table.  
Syntax  
INTEGER  
MaxAccess  
read-only  
Status  
mandatory  
Return Value  
Returns the number of entries registered in the Simple Name Server for all  
switches.  
connUnitSnsId (1.3.6.1.3.94.5.2.1.1.1)  
The connUnitId of the connectivity unit that contains this Name Server table.  
Syntax  
OCTET STRING (SIZE (16))  
Access  
read-only  
Status  
mandatory  
Return Value  
Returns the World Wide Name of the switch followed by 8 bytes of zeros.  
For example: 10 00 00 C0 DD 00 71 C9 00 00 00 00 00 00 00 00.  
connUnitSnsPortIndex (1.3.6.1.3.94.5.2.1.1.2)  
The physical port number of this SNS table entry. Each physical port has an SNS  
table with 1-n entries indexed by ConnUnitSnsPortIdentifier (port address).  
Syntax  
INTEGER  
Access  
read-only  
59047-09 C  
5-85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Simple Name Server Table  
S
Status  
mandatory  
Return Value  
The name server table index.  
connUnitSnsPortIdentifier (1.3.6.1.3.94.5.2.1.1.3)  
The port identifier for this entry in the SNS table.  
Syntax  
FcAddressId  
Access  
read-only  
Status  
mandatory  
Return Value  
The 24-bit Fibre Channel address for each entry in the name server table  
based on Domain, Area, and ALPA.  
connUnitSnsPortName (1.3.6.1.3.94.5.2.1.1.4)  
The Port World Wide Name for this entry in the SNS table.  
Syntax  
FcNameId  
Access  
read-only  
Status  
mandatory  
Return Value  
The Port World Wide Name of the device in the name server table.  
connUnitSnsNodeName (1.3.6.1.3.94.5.2.1.1.5)  
The Node name for this entry in the SNS table.  
Syntax  
FcNameId  
5-86  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Simple Name Server Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
The Node World Wide Name of the device in the name server table.  
connUnitSnsClassOfSvc (1.3.6.1.3.94.5.2.1.1.6)  
The classes of service offered by this entry in the SNS table.  
Syntax  
OCTET STRING (SIZE (1))  
Access  
read-only  
Status  
mandatory  
Return Value  
A value indicating the first registered class of service for an entry in the  
name server table. This is a bit mask where each bit that represents the  
class of service is set to a value of one if the class is supported. Class 1 is bit  
zero.  
connUnitSnsNodeIPAddress (1.3.6.1.3.94.5.2.1.1.7)  
The IPv6 formatted address of the Node for this entry in the SNS table.  
Syntax  
OCTET STRING (SIZE (16))  
Access  
read-only  
Status  
mandatory  
Return Value  
The switch IP address in IPv6 format.  
59047-09 C  
5-87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Simple Name Server Table  
S
connUnitSnsProcAssoc (1.3.6.1.3.94.5.2.1.1.8)  
The process associator for this entry in the SNS table.  
Syntax  
OCTET STRING (SIZE (16))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
connUnitSnsFC4Type (1.3.6.1.3.94.5.2.1.1.9)  
The FC-4 types supported by this entry in the SNS table.  
Syntax  
OCTET STRING (SIZE (32))  
Access  
read-only  
Status  
mandatory  
Return Value  
A value indicating the FC-4 Types registered for the device in the name  
server table. This is a 32 byte field with each bit uniquely identifying the FC-4  
Type registered as defined in FC-GS-3 specification. Example: SCSI FCP  
(bit 8) = 00 00 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  
00 00 00 00 00 00 00 00 00 00.  
connUnitSnsPortType (1.3.6.1.3.94.5.2.1.1.10)  
The port type of this entry in the SNS table.  
Syntax  
OCTET STRING (SIZE (1))  
Access  
read-only  
5-88  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Simple Name Server Table  
A
Status  
mandatory  
Return Value  
A value indicating the PortType for the entry in the name server table. Refer  
to Table 5-27 for connUnitPortType port type return values.  
Table 5-27. ConnUnitPortType State Return Values  
Port Type  
Return Value (hexidecimal)  
N
1
NL  
F/NL  
NX  
F
2
3
7F  
8
FL  
E
82  
84  
85  
B
connUnitSnsPortIPAddress (1.3.6.1.3.94.5.2.1.1.11)  
The IPv6 formatted address of this entry in the SNS table.  
Syntax  
OCTET STRING (SIZE (16))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
connUnitSnsFabricPortName (1.3.6.1.3.94.5.2.1.1.12)  
The fabric port name of this entry in the SNS table.  
Syntax  
FcNameId  
59047-09 C  
5-89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Simple Name Server Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
The switch port Port World Wide Name for the device in the name server  
table.  
connUnitSnsHardAddress (1.3.6.1.3.94.5.2.1.1.13)  
The hard ALPA of this entry in the SNS table.  
Syntax  
FcAddressId  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
connUnitSnsSymbolicPortName (1.3.6.1.3.94.5.2.1.1.14)  
The symbolic port name of this entry in the SNS table.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
The symbolic Port Name registered by the device in the name server table. If  
not registered, returns (NULL).  
5-90  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Platform Table  
A
connUnitSnsSymbolicNodeName (1.3.6.1.3.94.5.2.1.1.15)  
The symbolic Node name of this entry in the SNS table.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
The symbolic Node Name registered by the device in the name server table.  
If not registered, returns (NULL).  
Platform Table  
The Platform Table is a simple, read-only view of platform registration entries.  
Platform registry is a service hosted by the connectivity unit, in a very similar  
manner as the SNS table. The platform table is contained by the connectivity unit.  
A platform can register it's attributes and platform nodes with the registry service.  
The platform table is a flat, double-indexed MIB table. To keep the table simple,  
only one platform management URL is exposed. If a platform registers more than  
one management URL, the first one is reported in this table. This table is based on  
the fabric configuration server defined in the FC-GS-3 standard and enhanced  
platform attributes proposed for FC-GS-4. Note that the information contained in  
this table may only contain the platforms that this connUnit can see or it may  
contain a fabric wide view of the platforms.  
connUnitPlatformMaxEntry (1.3.6.1.3.94.5.1.2)  
The maximum number of entries in the platform table.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
59047-09 C  
5-91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5 – Fibre Alliance MIB Objects  
Platform Table  
S
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformIndex (1.3.6.1.3.94.5.2.2.1.1)  
Unique table index for each platform. Valid values are between 1 and  
connUnitPlatformsMaxEntry.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformNodeIndex (1.3.6.1.3.94.5.2.2.1.2)  
Unique table index for each platform node. Valid values are between 1 and  
connUnitPlatformsNumNodes.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformUnitID (1.3.6.1.3.94.5.2.2.1.3)  
The connUnitId of the connectivity unit that contains this Platform table.  
Syntax  
FcGlobalId  
Access  
read-only  
5-92  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Platform Table  
A
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformName (1.3.6.1.3.94.5.2.2.1.4)  
The platform name. May be either a readable string or a unique ID format as  
specified in the FC-GS-4 draft standard.  
Syntax  
OCTET STRING (SIZE(79))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformType (1.3.6.1.3.94.5.2.2.1.6)  
The platform type.  
Syntax  
FcUnitType  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformLabel (1.3.6.1.3.94.5.2.2.1.7)  
An administratively assigned symbolic name for the platform. The Platform Label  
shall only contain print-able ASCII characters.  
Syntax  
DisplayString (SIZE (0..79))  
59047-09 C  
5-93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Platform Table  
S
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformDescription (1.3.6.1.3.94.5.2.2.1.8)  
A textual description of the platform. This value should include the full name and  
version identification of the platform's hardware type and software operating  
system. The Platform Description shall only contain printable ASCII characters.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformLocation (1.3.6.1.3.94.5.2.2.1.9)  
The physical location of the platform (e.g., telephone closet, 3rd floor). The  
Platform Location shall only contain printable ASCII characters.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
5-94  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Platform Table  
A
connUnitPlatformManagementUrl (1.3.6.1.3.94.5.2.2.1.10)  
Primary management URL for the platform. If the platform registers more than one  
URL, then this URL is equal to the first in the list.  
Syntax  
DisplayString (SIZE (0..79))  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformNumNodes (1.3.6.1.3.94.5.2.2.1.11)  
Number of nodes contained in the platform.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
Unsupported. Always returns error status "NoSuchName"  
connUnitPlatformNodeName (1.3.6.1.3.94.5.2.2.1.12)  
The name (WWN - world wide name) of the node contained by the platform.  
Syntax  
FcGlobalId  
Access  
read-only  
Status  
read-only  
59047-09 C  
5-95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Trap Table  
S
Return Value  
Unsupported. Always returns error status "NoSuchName"  
Trap Table  
Traps are asynchronous messages sent from the agent (residing on the switch) to  
the manager (residing on the workstation) to identify significant events.  
There can be up to 5 trap addresses within the trap table. All trap information is  
stored within the switch and is accessible to Telnet and the SNMP agent, and is  
persistent between boots. An example of how to access one of these objects  
given an IP address of 10.32.165.4 is:  
"snmpget localhost public  
fcmgmt.trapReg.trapRegTable.trapRegEntry.trapRegFilter.10.32.165.4  
.162".  
A trap event is reported when the incoming error has a severity level less than or  
equal to the configured severity level. The trap event types and trap severity levels  
are listed in Table 5-28.  
Table 5-28. Trap Severity Levels  
Event Type  
Severity Level  
Unknown  
Emergency  
Alert  
1
2
3
Critical  
Error  
4
5
Warning  
Notify  
6
7
Info  
8
Debug  
Mark  
9
10  
trapMaxClients (1.3.6.1.3.94.2.1)  
The maximum number of SNMP trap recipients supported by the connectivity unit.  
Syntax  
INTEGER  
5-96  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                             
5 – Fibre Alliance MIB Objects  
Trap Table  
A
Access  
read-only  
Status  
mandatory  
Return Value  
Always returns 5.  
trapClientCount (1.3.6.1.3.94.2.2)  
The current number of rows in the trap table.  
Syntax  
INTEGER  
Access  
read-only  
Status  
mandatory  
Return Value  
A value (1-5) indicating number of configured trap clients.  
trapRegIpAddress (1.3.6.1.3.94.2.3.1.1)  
The IP address of a client registered for traps.  
Syntax  
IpAddress  
Access  
read-only  
Status  
mandatory  
Return Value  
The IP addresses (as defined in the trap table) of where to send traps when  
they occur.  
59047-09 C  
5-97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 – Fibre Alliance MIB Objects  
Trap Table  
S
trapRegPort (1.3.6.1.3.94.2.3.1.2)  
The UDP port to send traps to for this host. Normally this would be the standard  
trap port (162). This object is an index and must be specified to create a row in  
this table.  
Syntax  
INTEGER (1..2147483647)  
Access  
read-only  
Status  
mandatory  
Return Value  
The configured port number of where to send traps when they occur. The  
port number can be configured in the switch SNMP setup parameters.  
Default is 162.  
trapRegFilter (1.3.6.1.3.94.2.3.1.3)  
This value defines the trap severity filter for this trap host. The connUnit will send  
traps to this host that have a severity level less than or equal to this value. The  
default value of this object is “warning”.  
Syntax  
FcEventSeverity  
Access  
read-write  
Status  
mandatory  
Return Value  
A value indicating the trap severity level. Refer to Table 5-28 for trap severity  
levels.  
trapRegRowState (1.3.6.1.3.94.2.3.1.4)  
Specifies the state of the row.  
rowDestroy  
READ: Can never happen.  
WRITE: Remove this row from the table.  
5-98  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5 – Fibre Alliance MIB Objects  
Trap Table  
A
rowInactive  
READ: Indicates that this row does exist, but that traps are not enabled  
to be sent to the target.  
WRITE: If the row does not exist, and the agent allows writes to the  
trap table, then a new row is created. The values of the optional  
columns will be set to default values. Traps are not enabled to be sent  
to the target. If the row already existed, then traps are disabled from  
being sent to the target.  
rowActive  
READ: Indicates that this row exists, and that traps are enabled to be  
sent to the target.  
WRITE: If the row does not exist, and the agent allows writes to the  
trap table, then a new row is created. The values of the optional  
columns will be set to default values. Traps are enabled to be sent to  
the target. If the row already exists, then traps are enabled to be sent  
to the target.  
A value of “rowActive” or “rowInactive” must be specified to create a row in  
the table.  
Syntax  
INTEGER {  
rowDestroy(1), - Remove row from table.  
rowInactive(2), - Row exists, but traps disabled  
rowActive(3) - Row exists and is enabled for sending traps  
}
Access  
read-write  
Status  
mandatory  
Return Value  
Returns rowActive (3), if valid entry in trap table.  
59047-09 C  
5-99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 – Fibre Alliance MIB Objects  
Related Traps  
S
Related Traps  
The following traps contain the trap information being sent from the agent to the  
manager.  
connUnitStatusChange (1.3.6.1.3.94.0.1)  
The overall status of the connectivity unit has changed. The recommended  
severity level (for filtering) is “alert”. Sent whenever a Switch.OperChange or  
Switch.StateChange event occurs.  
Variables: { connUnitStatus, connUnitState }  
connUnitDeletedTrap (1.3.6.1.3.94.0.3)  
A connUnit has been deleted from this agent. The recommended severity level  
(for filtering) is “warning”. Sent whenever an Eport.OperChange event occurs and  
the connUnitTable is smaller than previously noted (A connUnit has gone away).  
Variables: { connUnitId }  
connUnitEventTrap (1.3.6.1.3.94.0.4)  
An event has been generated by the connectivity unit. The recommended severity  
level (for filtering) is “info”. Sent when a change notification occurs that does not fit  
into any other specific category.  
Variables:  
{ connUnitEventId, connUnitEventType, connUnitEventObject,  
connUnitEventDescr }  
Figure 5-1 provides the standard format of the connUnitEventDescr variable.  
Chassis, Blade, and Port are always 0.  
Chassis  
Tag #  
Port  
27; 33; 0; 0; 0; [TimeDate] [Module] [Addr] [Descr]  
Event #  
Blade  
Figure 5-1 connUnitEventDescr Variable Format  
Table 5-29 lists the fields in the connUnitEventDescr variable.  
5-100  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5 – Fibre Alliance MIB Objects  
Related Traps  
A
Table 5-29. connUnitEventDescr Variable Field Descriptions  
connUnitEventDescr Variable  
Description  
Tag #  
The number that identifies the event.  
The event counter.  
Event #  
Chassis  
Blade  
The switch on which the event occurred.  
The I/O blade on which the event  
occurred.  
Port  
The port on which the event occurred.  
The time stamp of the event.  
TimeDate  
Module  
The software module where the event was  
initiated.  
Addr  
The address in the software module where  
the event was initiated.  
Descr  
The description of the event.  
Table 5-30 lists the trap information returned for the connUnitEventDescr variable.  
Table 5-30. Filter Trap Levels  
Trap Type  
Cause  
Filter Level  
connUnitPortStatusChange  
User port config change  
User port state change  
E_Port alarm  
eventSeverity_info  
eventSeverity_info  
eventSeverity_critical  
connUnitDeletedTrap  
connUnitStatusChange  
Fabric change and unit  
deleted  
eventSeverity_info  
Switch state change  
Switch reset  
eventSeverity_info  
eventSeverity_critical  
59047-09 C  
5-101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Related Traps  
S
Table 5-30. Filter Trap Levels  
Trap Type  
Cause  
Filter Level  
connUnitSensorStatusChange Power supply bad alarm  
Power supply OK alarm  
Fan bad alarm  
eventSeverity_critical  
eventSeverity_critical  
eventSeverity_critical  
eventSeverity_critical  
eventSeverity_critical  
eventSeverity_critical  
eventSeverity_critical  
Fan OK alarm  
Overheat alarm  
Overwarm alarm  
Temperature OK alarm  
connUnitEventTrap  
SNMP config change  
Switch config change  
System config change  
Topology change  
Zoning change  
eventSeverity_info  
eventSeverity_info  
eventSeverity_info  
eventSeverity_info  
eventSeverity_info  
eventSeverity_critical  
eventSeverity_info  
eventSeverity_critical  
eventSeverity_warning  
Zoning merge failure  
NameServer change  
Generic alarm  
Generic event  
connUnitSensorStatusChange (1.3.6.1.3.94.0.5)  
The overall status of the connectivity unit has changed. The recommended  
severity level (for filtering) is “alert”. Sent whenever any of the following  
notifications occur:  
Chassis.PsBadAlarm  
Chassis.PsOkAlarm  
Chassis.FanBadAlarm  
Chassis.FanOkAlarm  
Blade.OverheatAlarm  
Blade.OverwarmAlarm  
Variables: { connUnitSensorStatus }  
connUnitPortStatusChange (1.3.6.1.3.94.0.6)  
The overall status of the connectivity unit has changed. The recommended  
severity level (for filtering) is “alert”. Sent whenever a UserPort.StateChange or  
UserPort.OperChange event occurs.  
5-102  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Related Traps  
A
Enterprise: fcmgmt  
Variables: { connUnitPortStatus, connUnitPortState }  
coldStart  
A coldStart trap signifies that the SNMPv2 entity, acting in an agent role, is  
re-initializing itself and that its configuration may have been altered.  
authenticationFailure  
An authenticationFailure trap signifies that the SNMPv2 entity, acting in an agent  
role, has received a protocol message that is not properly authenticated. While all  
implementations of the SNMPv2 must be capable of generating this trap, the  
snmpEnableAuthenTraps object indicates whether this trap will be generated.  
59047-09 C  
5-103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 – Fibre Alliance MIB Objects  
Related Traps  
S
Notes  
5-104  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 Fabric Element MIB Objects  
This section covers the implementation details for the Fabric Element  
Management Information Bases (FE-MIB) on the SANbox switch.  
Fibre Channel FE MIB Definitions  
The textual substitutions in Table 6-1 are specific to the FE-MIB and can be used  
in place of primitive data types.  
Table 6-1. FA-MIB Textual Substitutions  
Description  
Syntax  
MilliSeconds  
Unsigned32  
MicroSeconds  
FcNameId  
Unsigned32  
OCTET STRING (SIZE (8))  
OCTET STRING (SIZE (3))  
Integer32 (128..2112)  
Integer32 (0..32767)  
Integer32 (0..255)  
FcAddressId  
FcRxDataFieldSize  
FcBbCredit  
FcphVersion  
FcStackedConnMode INTEGER {  
none(1),  
transparent(2),  
lockedDown(3)  
}
59047-09 C  
6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
6 – Fabric Element MIB Objects  
Configuration Group  
S
Table 6-1. FA-MIB Textual Substitutions  
Description  
Syntax  
FcCosCap  
BITS {  
classF(0),  
class1(1),  
class2(2),  
class3(3),  
class4(4),  
class5(5),  
class6(6)  
}
FcCosCap  
BITS {  
classF(0),  
class1(1),  
class2(2),  
class3(3),  
class4(4),  
class5(5),  
class6(6)  
}
FcFeModuleCapacity Unsigned32  
FcFeFxPortCapacity  
FcFeModuleIndex  
FcFeFxPortIndex  
FcFeNxPortIndex  
FcBbCreditModel  
Unsigned32  
Unsigned32  
Unsigned32  
Integer32 (1..126)  
INTEGER { regular(1), alternate (2) }  
Configuration Group  
This group consists of scalar objects and tables. It contains the configuration and  
service parameters of the Fabric Element and the FxPorts. The group represents  
a set of parameters associated with the Fabric Element or an FxPort to support its  
NxPorts. The objects described in this section are not in a table format. An  
example of how to access one of these objects is:  
"snmpget localhost public fcFeFabricName.0".  
6-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6 – Fabric Element MIB Objects  
Configuration Group  
A
fcFeFabricName (1.3.6.1.2.1.75.1.1.1)  
The Name_Identifier of the Fabric to which this Fabric Element belongs.  
Syntax  
FcNameId  
Access  
read-write  
Status  
Current  
Return Value  
The World Wide Name of the principal switch. For example, 10 00 00 C0 DD  
00 71 C2. Writes are not supported.  
fcFeElementName (1.3.6.1.2.1.75.1.1.2)  
The Name_Identifier of the Fabric Element.  
Syntax  
FcNameId  
Access  
read-write  
Status  
Current  
Return Value  
The World Wide Name of the switch. For example, 10 00 00 C0 DD 00 71  
C9. Writes are not supported.  
fcFeModuleCapacity (1.3.6.1.2.1.75.1.1.3)  
The maximum number of modules in the Fabric Element, regardless of their  
current state.  
Syntax  
FcFeModuleCapacity  
Access  
read-only  
Status  
Current  
59047-09 C  
6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Module Table  
S
Return Value  
The total number of switches in the fabric if ProxyEnable setting is Enabled  
on the out-of-band switch. If ProxyEnable setting is disabled on the  
out-of-band switch, return value = 1.  
Module Table  
The objects described in this section are in table format indexed by switch. An  
example of how to access one of these objects is: "snmpget localhost public  
fcFeModuleDescr.1". This table contains one entry for each module.  
fcFeModuleDescr (1.3.6.1.2.1.75.1.1.4.1.2)  
A textual description of the module. This value should include the full name and  
version identification of the module.  
Syntax  
SnmpAdminString  
Access  
read-only  
Status  
current  
Return Value  
A configuration description of the module table entry. The defaults are:  
SANbox 5200 = SANbox 5200 FC Switch, SANbox 5202 = SANbox 5202  
FC Switch, SANbox 5600 = SANbox 5600 FC Switch, SANbox 5602 =  
SANbox 5602 FC Switch  
fcFeModuleObjectID (1.3.6.1.2.1.75.1.1.4.1.3)  
The vendor's authoritative identification of the module. This value may be  
allocated within the SMI enterprises subtree (1.3.6.1.4.1), and provides a means  
for determining what kind of module is being managed.  
For example, this object could take the value 1.3.6.1.4.1.99649.3.9 if vendor  
“Neufe Inc.” was assigned the subtree 1.3.6.1.4.1.99649, and had assigned the  
identifier 1.3.6.1.4.1.99649.3.9 to its FeFiFo-16 PlugInCard.  
Syntax  
OBJECT IDENTIFIER  
Access  
read-only  
6-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Module Table  
A
Status  
current  
Return Value  
The module identification numbers are: SANbox 5200 =  
1.3.6.1.4.1.1663.1.1.1.1.17, SANbox 5202 = 1.3.6.1.4.1.1663.1.1.1.1.30,  
SANbox 5600 = 1.3.6.1.4.1.1663.1.1.1.1.23, SANbox 5602 =  
1.3.6.1.4.1.1663.1.1.1.1.24  
fcFeModuleOperStatus (1.3.6.1.2.1.75.1.1.4.1.4)  
Switch definitions map 1-to-1 with the MIB definitions. This object indicates the  
operational status of the module.  
online (1) - the module is functioning properly  
offline (2) - the module is not available  
testing (3) - the module is under testing  
faulty (4) - the module is defective in some way  
Syntax  
INTEGER {  
online(1), - functional  
offline(2), - not available  
testing(3), - under testing  
faulty(4) - defective  
}
Access  
read-only  
Status  
Current  
Return Value  
The operational status of that module.  
Table 6-2. Module Operational Status Return Values  
Mode Return Value  
online  
online(1)  
offline(2)  
testing(3)  
offline  
diagnostics  
59047-09 C  
6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6 – Fabric Element MIB Objects  
Module Table  
S
Table 6-2. Module Operational Status Return Values  
Mode  
Return Value  
other  
faulty(4)  
fcFeModuleLastChange (1.3.6.1.2.1.75.1.1.4.1.5)  
This object contains the value of sysUpTime when the module entered its current  
operational status. A value of zero indicates that the operational status of the  
module has not changed since the agent last restarted.  
Syntax  
TimeStamp  
Access  
read-only  
Status  
Current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFeModuleFxPortCapacity (1.3.6.1.2.1.75.1.1.4.1.6)  
The number of FxPort that can be contained within the module. Within each  
module, the ports are uniquely numbered in the range from 1 to  
fcFeModuleFxPortCapacity inclusive. However, the numbers are not required to  
be contiguous.  
Syntax  
FcFeFxPortCapacity  
Access  
read-only  
Status  
current  
Return Value  
The total number of ports capability on the switch. SANbox 5200/5600  
Series = 1 - 8, 12, 16, 20 (varies depending on number of licensed ports)  
fcFeModuleName (1.3.6.1.2.1.75.1.1.4.1.7)  
The Name_Identifier of the switch.  
6-6  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
FxPort Configuration Table  
A
Syntax  
FcNameId  
Access  
read-write  
Status  
current  
Return Value  
The World Wide Name of the switch. Writes are not supported. For example,  
10 00 00 C0 DD 00 71 C9.  
FxPort Configuration Table  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: snmpget  
localhost public fcFxPortName.1.1. This table contains one entry for each FxPort  
and Configuration parameters of the ports. This table contains, one entry for each  
FxPort, configuration parameters of the ports.  
fcFxPortName (1.3.6.1.2.1.75.1.1.5.1.2)  
The World Wide Name of this FxPort. Each FxPort has a unique Port World Wide  
Name within the Fabric.  
Syntax  
FcNameId  
Access  
read-only  
Status  
current  
Return Value  
Returns the Port World Wide Name for each port on switch. For example,  
the return value for port #2 would be 20 02 00 C0 DD 00 71 C9, and the  
return value for port #14 would be 20 0E 00 C0 DD 00 71 C9.  
fcFxPortFcphVersionHigh (1.3.6.1.2.1.75.1.1.5.1.3)  
The highest or most recent version of FC-PH that the FxPort is configured to  
support.  
59047-09 C  
6-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
FxPort Configuration Table  
S
Syntax  
FcphVersion  
Access  
read-only  
Status  
Current  
Return Value  
Always returns 32 (0x20).  
fcFxPortFcphVersionLow (1.3.6.1.2.1.75.1.1.5.1.4)  
The lowest or earliest version of FC-PH that the FxPort is configured to support.  
Syntax  
FcphVersion  
Access  
read-only  
Status  
current  
Return Value  
Always returns 9.  
fcFxPortBbCredit (1.3.6.1.2.1.75.1.1.5.1.5)  
The total number of receive buffers available for holding Class 1 connect-request,  
Class 2, or Class3 frames from the attached NxPort. It is for buffer-to-buffer flow  
control in the direction from the attached NxPort (if applicable) to FxPort.  
Syntax  
FcBbCredit  
Access  
read-only  
Status  
current  
Return Value  
The default number of receive buffers for each port, unless extended credits  
are used. SANbox 5200/5600 Series = 16  
6-8  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
FxPort Configuration Table  
A
fcFxPortRxBufSize (1.3.6.1.2.1.75.1.1.5.1.6)  
The largest Data_Field Size (in octets) for an FT_1 frame that can be received by  
the FxPort.  
Syntax  
FcRxDataFieldSize  
Access  
read-only  
Status  
current  
Return Value  
Always returns 2112 (0x840).  
fcFxPortRatov (1.3.6.1.2.1.75.1.1.5.1.7)  
The Resource_Allocation_Timeout Value configured for the FxPort. This is used  
as the timeout value for determining when to reuse an NxPort resource such as a  
Recovery_Qualifier. It represents E_D_TOV plus twice the maximum time that a  
frame may be delayed within the fabric and still be delivered. Refer to  
Syntax  
MilliSeconds  
Access  
read-only  
Status  
Current  
Return Value  
The default is: 10000 (0x2710).  
fcFxPortEdtov (1.3.6.1.2.1.75.1.1.5.1.8)  
The E_D_TOV value configured for the FxPort. The Error_Detect_Timeout Value  
is used as the timeout value for detecting an error condition.  
Syntax  
MilliSeconds  
Access  
read-only  
59047-09 C  
6-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
FxPort Configuration Table  
S
Status  
current  
Return Value  
The default is: 2000 (0x7D0).  
fcFxPortCosSupported (1.3.6.1.2.1.75.1.1.5.1.9)  
A value indicating the set of classes of service supported by the FxPort.  
Syntax  
FcCosCap  
Access  
read-only  
Status  
Current  
Return Value  
Always returns Class 3, 2, and F (0x0D).  
fcFxPortIntermixSupported (1.3.6.1.2.1.75.1.1.5.1.10)  
A flag indicating whether or not the FxPort supports an Intermixed Dedicated  
Connection.  
Syntax  
TruthValue  
Access  
read-only  
Status  
current  
Return Value  
Always returns False (2).  
fcFxPortStackedConnMode (1.3.6.1.2.1.75.1.1.5.1.11)  
A value indicating the mode of Stacked Connect supported by the FxPort.  
Syntax  
FcStackedConnMode  
6-10  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
FxPort Configuration Table  
A
Access  
read-only  
Status  
current  
Return Value  
Always returns None (1).  
fcFxPortClass2SeqDeliv (1.3.6.1.2.1.75.1.1.5.1.12)  
A flag indicating whether or not Class 2 Sequential Delivery is supported by the  
FxPort.  
Syntax  
TruthValue  
Access  
read-only  
Status  
current  
Return Value  
Always returns True (1).  
fcFxPortClass3SeqDeliv (1.3.6.1.2.1.75.1.1.5.1.13)  
A flag indicating whether or not Class 3 Sequential Delivery is supported by the  
FxPort.  
Syntax  
TruthValue  
Access  
read-only  
Status  
current  
Return Value  
Always returns True (1).  
59047-09 C  
6-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
The Status Group  
S
fcFxPortHoldTime (1.3.6.1.2.1.75.1.1.5.1.14)  
The maximum time, in microseconds, that the FxPort shall hold a frame before  
discarding the frame if it is unable to deliver the frame. The value 0 means that the  
FxPort does not support this parameter.  
Syntax  
MicroSeconds  
Access  
read-only  
Status  
current  
Return Value  
The default ED_TOV parameter is: 2000 (0x7D0).  
The Status Group  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortId.1.1". This group consists of tables that contain  
operational status and established service parameters for the Fabric Element and  
the attached NxPorts.  
This group consists of tables that contains operational status and established  
service parameters for the Fabric Element and the attached NxPorts. This table  
contains one entry for each FxPort, and the operational status and parameters of  
the FxPorts.  
fcFxPortID (1.3.6.1.2.1.75.1.2.1.1.1)  
The address identifier by which this FxPort is identified within the fabric. The  
FxPort may assign its address identifier to its attached NxPort(s) during Fabric  
Login.  
Syntax  
FcAddressId  
Access  
read-only  
Status  
current  
6-12  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
The Status Group  
A
Return Value  
The address of each port based on Domain, Area, and ALPA. Example, 64  
03 00.  
fcFxPortBbCreditAvailable (1.3.6.1.2.1.75.1.2.1.1.2)  
The number of buffers currently available for receiving frames from the attached  
port in the buffer-to-buffer flow control. The value should be less than or equal to  
fcFxPortBbCredit.  
Syntax  
Gauge32  
Access  
read-only  
Status  
Current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortOperMode (1.3.6.1.2.1.75.1.2.1.1.3)  
The current operational mode of the FxPort.  
Syntax  
INTEGER { unknown(1), fPort(2), flPort(3) }  
Access  
read-only  
Status  
current  
Return Value  
Refer to Table 6-3 for fcFxPortOperMode return values.  
Table 6-3. Port Operational Modes  
Mode  
Return Value  
Unknown  
1
2
3
F_Port  
FL_Port  
59047-09 C  
6-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
6 – Fabric Element MIB Objects  
FxPort Physical Level Table  
S
fcFxPortAdminMode (1.3.6.1.2.1.75.1.2.1.1.4)  
The desired operational mode of the FxPort.  
Syntax  
INTEGER { fPort(2), flPort(3) }  
Access  
read-write  
Status  
Current  
Return Value  
Unsupported. Always returns error status 'NoSuchName'.  
FxPort Physical Level Table  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortPhysAdminStatus.1.1". This table contains one entry for  
each FxPort in the Fabric Element, the physical level status, and parameters of  
the FxPorts.  
This table contains one entry for each FxPort in the Fabric Element, and the  
physical level status and parameters of the FxPorts.  
fcFxPortPhysAdminStatus (1.3.6.1.2.1.75.1.2.2.1.1)  
The desired state of the FxPort. A management station may place the FxPort in a  
desired state by setting this object accordingly. The testing(3) state indicates that  
no operational frames can be passed. When a Fabric Element initializes, all  
FxPorts start with fcFxPortPhysAdminStatus in the offline(2) state. As the result of  
either explicit management action or per configuration information accessible by  
the Fabric Element, fcFxPortPhysAdminStatus is then changed to either the  
online(1) or testing(3) states, or remains in the offline state.  
Syntax  
INTEGER {  
online(1), - place port online  
offline(2), - take port offline  
testing(3) - initiate test procedures  
}
Access  
read-write  
6-14  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
FxPort Physical Level Table  
A
Status  
current  
Return Value  
Refer to Table 6-4 for fcFxPortPhysAdminStatus read values.  
Table 6-4. fcFxPortPhysAdminStatus Read Return Values  
Port Value  
Online  
online (1)  
offline (2)  
testing (3)  
offline (2)  
Offline  
Diagnostics  
Down  
Refer to Table 6-5 for fcFxPortPhysAdminStatus write values.  
Table 6-5. fcFxPortPhysAdminStatus Write Values  
Port  
Value  
Online  
online (1)  
offline (2)  
testing (3)  
Offline  
Diagnostics  
fcFxPortPhysOperStatus (1.3.6.1.2.1.75.1.2.2.1.2)  
The current operational status of the FxPort. The testing(3) indicates that no  
operational frames can be passed. If fcFxPortPhysAdminStatus is offline(2), then  
fcFxPortPhysOperStatus should be offline(2). If fcFxPortPhysAdminStatus is  
changed to online(1), then fcFxPortPhysOperStatus should change to online(1). If  
the FxPort is ready to accept Fabric Login request from the attached NxPort, it  
should proceed and remain in the link- failure(4) state if, and only if, there is a fault  
that prevents it from going to the online(1) state.  
Syntax  
INTEGER {  
online(1), - Login may proceed  
offline(2), - Login cannot proceed  
testing(3), - port is under test  
linkFailure(4) - failure after online/testing  
}
59047-09 C  
6-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
FxPort Physical Level Table  
S
Access  
read-only  
Status  
current  
Return Value  
Refer to Table 6-6 for fcFxPortPhysOperStatus return values.  
Table 6-6. fcFxPortPHysOperStatus Return Values  
Status Return Value  
Online  
online (1)  
Offline  
offline (2)  
Diagnostic  
Down  
testing (3)  
linkfailure (4)  
fcFxPortPhysLastChange (1.3.6.1.2.1.75.1.2.2.1.3)  
The value of sysUpTime at the time the FxPort entered its current operational  
status. A value of zero indicates that the FxPort's operational status has not  
changed since the agent last restarted.  
Syntax  
TimeStamp  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortPhysRttov (1.3.6.1.2.1.75.1.2.2.1.4)  
The Receiver_Transmitter_Timeout value of the FxPort. This is used by the  
receiver logic to detect a loss of synchronization.  
Syntax  
Milliseconds  
6-16  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
6 – Fabric Element MIB Objects  
Fx Port Fabric Login Table  
A
Access  
read-write  
Status  
current  
Return Value  
The default RT_TOV parameter is: 100 (0x64). This is a global setting for the  
switch. If writing value to a port, all ports will reflect this new value.  
Fx Port Fabric Login Table  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortFcphVersionAgreed.1.1". This table contains one entry  
for each FxPort in the fabric element and the service parameters that have been  
established from the most recent Fabric Login (implicit or explicit).  
This table contains one entry for each FxPort in the fabric element, and the  
service parameters that have been established from the most recent Fabric Login,  
implicit or explicit.  
fcFxPortFcphVersionAgreed (1.3.6.1.2.1.75.1.2.3.1.2)  
The version of FC-PH that the FxPort has agreed to support from the Fabric  
Login.  
Syntax  
FcphVersion  
Access  
read-only  
Status  
current  
Return Value  
Unsupported.  
fcFxPortNxPortBbCredit (1.3.6.1.2.1.75.1.2.3.1.3)  
The total number of buffers available for holding class 1 connect-request, class 2,  
or class 3 frames to be transmitted to the attached NxPort. It is for buffer-to-buffer  
flow control in the direction from FxPort to NxPort. The buffer-to-buffer flow control  
mechanism is indicated in the respective fcFxPortBbCreditModel.  
59047-09 C  
6-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Fx Port Fabric Login Table  
S
Syntax  
FcBbCredit  
Access  
read-only  
Status  
current  
Return Value  
Unsupported.  
fcFxPortNxPortRxDataFieldSize (1.3.6.1.2.1.75.1.2.3.1.4)  
The Receive Data Field Size of the attached NxPort. This object specifies the  
largest Data Field Size for an FT_1 frame that can be received by the NxPort.  
Syntax  
FcRxDataFieldSize  
Access  
read-only  
Status  
current  
Return Value  
Unsupported.  
fcFxPortCosSuppAgreed (1.3.6.1.2.1.75.1.2.3.1.5)  
A variable indicating that the attached NxPort has requested the FxPort for the  
support of classes of services and the FxPort has granted the request.  
Syntax  
FcCosCap  
Access  
read-only  
Status  
current  
6-18  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
Fx Port Fabric Login Table  
A
Return Value  
The bits have the following bit-mapped definition:  
Bit 7 Class-six  
Bit 6 Class-five  
Bit 5 Class-four  
Bit 4 Class-three  
Bit 3 Class-two  
Bit 2 Class-one  
Bit 1 Class F  
For example: If Class 3, return value 0x10.  
fcFxPortIntermixSuppAgreed (1.3.6.1.2.1.75.1.2.3.1.6)  
A variable indicating that the attached NxPort has requested the FxPort for the  
support of Intermix and the FxPort has granted the request. This flag is only valid  
if Class 1 service is supported.  
Syntax  
TruthValue  
Access  
read-only  
Status  
current  
Return Value  
Always returns false (2).  
fcFxPortStackedConnModeAgreed (1.3.6.1.2.1.75.1.2.3.1.7)  
A variable indicating whether the FxPort has agreed to support stacked connect  
from the Fabric Login. This is only meaningful if the ports are using Class 1  
service.  
Syntax  
FcStackedConnMode  
59047-09 C  
6-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
Fx Port Fabric Login Table  
S
Access  
read-only  
Status  
current  
Return Value  
Always returns none (1).  
fcFxPortClass2SeqDelivAgreed (1.3.6.1.2.1.75.1.2.3.1.8)  
A variable indicating whether the FxPort has agreed to support Class 2 sequential  
delivery from the Fabric Login. This is only meaningful if the ports are using Class  
2 service.  
Syntax  
TruthValue  
Access  
read-only  
Status  
Current  
Return Value  
Always returns true (1).  
fcFxPortClass3SeqDelivAgreed (1.3.6.1.2.1.75.1.2.3.1.9)  
A flag indicating whether the FxPort has agreed to support Class 3 sequential  
delivery from the Fabric Login. This is only meaningful if the ports are using Class  
3 service.  
Syntax  
TruthValue  
Access  
read-only  
Status  
current  
Return Value  
Always returns true (1).  
6-20  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
Fx Port Fabric Login Table  
A
fcFxPortNxPortName (1.3.6.1.2.1.75.1.2.3.1.10)  
The port name of the attached NxPort.  
Syntax  
FcNameId  
Access  
read-only  
Status  
Current  
Return Value  
Returns the Switch Port's Port World Wide Name for the attached device.  
fcFxPortConnectedNxPort (1.3.6.1.2.1.75.1.2.3.1.11)  
The address identifier of the destination NxPort with which this FxPort is currently  
engaged in a either a Class 1 or loop connection. If this FxPort is not engaged in a  
connection, then the value of this object is “000000”H.  
Syntax  
FcAddressId  
Access  
read-only  
Status  
Current  
Return Value  
Unsupported.  
fcFxPortBbCreditModel (1.3.6.1.2.1.75.1.2.3.1.12)  
This object identifies the BB_Credit model used by the FxPort.  
Syntax  
FcBbCreditModel  
Access  
read-write  
Status  
current  
59047-09 C  
6-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
The Error Group  
S
Return Value  
Returns alternate (2). Writes not supported.  
The Error Group  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortLinkFailures.1.1". This group consists of tables that  
contain information about the various types of errors detected. The management  
station may use the information in this group to determine the quality of the link  
between the FxPort and its attached NxPort.  
The FxPort Error table contains, one entry for each FxPort in the Fabric Element,  
counters recording numbers of errors detected since the management agent  
re-initialized. The first 6 columnar objects after the port index corresponds to the  
counters in the Link Error Status Block.  
fcFxPortLinkFailures (1.3.6.1.2.1.75.1.3.1.1.1)  
The number of link failures detected by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of LinkFailures encountered for a port.  
fcFxPortSyncLosses (1.3.6.1.2.1.75.1.3.1.1.2)  
The number of loss of synchronizations detected by the FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
6-22  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
The Error Group  
A
Return Value  
The total number of LossOfSyncs encountered for a port.  
fcFxPortSigLosses (1.3.6.1.2.1.75.1.3.1.1.3)  
The number of loss of signals detected by the FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortPrimSeqProtoErrors (1.3.6.1.2.1.75.1.3.1.1.4)  
The number of primitive sequence protocol errors detected by the FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of PrimSeqErrors encountered for a port.  
fcFxPortInvalidTxWords (1.3.6.1.2.1.75.1.3.1.1.5)  
The number of invalid transmission words detected by the FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
59047-09 C  
6-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
The Error Group  
S
Return Value  
The total number of DecodeErrors encountered for a port.  
fcFxPortInvalidCrcs (1.3.6.1.2.1.75.1.3.1.1.6)  
The number of invalid CRCs detected by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of InvalidCRCs encountered for a port.  
fcFxPortDelimiterErrors (1.3.6.1.2.1.75.1.3.1.1.7)  
The number of Delimiter Errors detected by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortAddressIdErrors (1.3.6.1.2.1.75.1.3.1.1.8)  
The number of address identifier errors detected by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
6-24  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
The Error Group  
A
Return Value  
The total number of InvDestAddrs encountered for a port.  
fcFxPortLinkResetIns (1.3.6.1.2.1.75.1.3.1.1.9)  
The number of Link Reset Protocols received by this FxPort from the attached  
NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of RxLinkResets received by a port.  
fcFxPortLinkResetOuts (1.3.6.1.2.1.75.1.3.1.1.10)  
The number of Link Reset Protocols issued by this FxPort to the attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of TxLinkResets sent by a port.  
fcFxPortOlsIns (1.3.6.1.2.1.75.1.3.1.1.11)  
The number of Offline Sequences received by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
59047-09 C  
6-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Accounting Groups  
S
Status  
current  
Return Value  
The total number of RxOfflineSeqs received by a port.  
fcFxPortOlsOuts (1.3.6.1.2.1.75.1.3.1.1.12)  
The number of Offline Sequences issued by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of TxOflineSeqs sent by a port.  
Accounting Groups  
Each group consists of a table that contains accounting information for the  
FxPorts in the Fabric Element: Class 1 Accounting Group, Class 2 Accounting  
Group, and Class 3 Accounting Group.  
Class 1 Accounting Table  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortC1InFrames.1.1". This table contains one entry for each  
FxPort in the Fabric Element and Counter32s for certain types of events that have  
occurred in the FxPorts since the management agent was re-initialized.  
fcFxPortC1InFrames (1.3.6.1.2.1.75.1.4.1.1.1)  
The number of Class 1 frames (other than Class 1 connect-request) received by  
this FxPort from its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
6-26  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
6 – Fabric Element MIB Objects  
Accounting Groups  
A
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1OutFrames (1.3.6.1.2.1.75.1.4.1.1.2)  
The number of Class 1 frames (other than Class 1 connect- request) delivered  
through this FxPort to its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1InOctets (1.3.6.1.2.1.75.1.4.1.1.3)  
The number of Class 1 frame octets, including the frame delimiters, received by  
this FxPort from its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1OutOctets (1.3.6.1.2.1.75.1.4.1.1.4)  
The number of Class 1 frame octets, including the frame delimiters, delivered  
through this FxPort its attached NxPort.  
Syntax  
Counter32  
59047-09 C  
6-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Accounting Groups  
S
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1Discards (1.3.6.1.2.1.75.1.4.1.1.5)  
The number of Class 1 frames discarded by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1FbsyFrames (1.3.6.1.2.1.75.1.4.1.1.6)  
The number of F_BSY frames generated by this FxPort against Class 1  
connect-request.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1FrjtFrames (1.3.6.1.2.1.75.1.4.1.1.7)  
The number of F_RJT frames generated by this FxPort against Class 1  
connect-request.  
6-28  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Accounting Groups  
A
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1InConnections (1.3.6.1.2.1.75.1.4.1.1.8)  
The number of Class 1 connections successfully established in which the  
attached NxPort is the source of the connect-request.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
fcFxPortC1OutConnections (1.3.6.1.2.1.75.1.4.1.1.9)  
The number of Class 1 connections successfully established in which the  
attached NxPort is the destination of the connect-request.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
59047-09 C  
6-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
Class 2 Accounting Table  
S
fcFxPortC1ConnTime (1.3.6.1.2.1.75.1.4.1.1.10)  
The cumulative time that this FxPort has been engaged in Class 1 connection.  
The amount of time is counted from after a connect-request has been accepted  
until the connection is disengaged, either by an EOFdt or Link Reset.  
Syntax  
Milliseconds  
Access  
read-only  
Status  
current  
Return Value  
Unsupported. Always returns error status "NoSuchName".  
Class 2 Accounting Table  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortC2InFrames.1.1". This table contains one entry for each  
FxPort in the Fabric Element and Counter32s for certain types of events that have  
occurred in the FxPorts since the management agent was re-initialized.  
fcFxPortC2InFrames (1.3.6.1.2.1.75.1.4.2.1.1)  
The number of Class 2 frames received by this FxPort from its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class2FramesIn received by a port.  
fcFxPortC2OutFrames (1.3.6.1.2.1.75.1.4.2.1.2)  
The number of Class 2 frames delivered through this FxPort to its attached  
NxPort.  
6-30  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
6 – Fabric Element MIB Objects  
Class 2 Accounting Table  
A
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class2FramesOut sent by a port.  
fcFxPortC2InOctets (1.3.6.1.2.1.75.1.4.2.1.3)  
The number of Class 2 frame octets, including the frame delimiters, received by  
this FxPort from its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class2WordsIn received by a port.  
fcFxPortC2OutOctets (1.3.6.1.2.1.75.1.4.2.1.4)  
The number of Class 2 frame octets, including the frame delimiters, delivered  
through this FxPort to its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class2WordsOut sent by a port.  
59047-09 C  
6-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
Class 2 Accounting Table  
S
fcFxPortC2Discards (1.3.6.1.2.1.75.1.4.2.1.5)  
The number of Class 2 frames discarded by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class2Toss discarded by a port.  
fcFxPortC2FbsyFrames (1.3.6.1.2.1.75.1.4.2.1.6)  
The number of F_BSY frames generated by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of FBusy frames generated by this port for Class 2 and 3  
frames.  
fcFxPortC2FrjtFrames (1.3.6.1.2.1.75.1.4.2.1.7)  
The number of F_RJT frames generated by this FxPort against Class 2 frames.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
6-32  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Class 3 Accounting Table  
A
Return Value  
The total number of FReject frames generated by this port for Class 2 and 3  
frames.  
Class 3 Accounting Table  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortC3InFrames.1.1". This table contains one entry for each  
FxPort in the Fabric Element and Counter32s for certain types of events that have  
occurred in the FxPorts since the management agent has re-initialized.  
fcFxPortC3InFrames (1.3.6.1.2.1.75.1.4.3.1.1)  
The number of Class 3 frames received by this FxPort from its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class3FramesIn received by a port.  
fcFxPortC3OutFrames (1.3.6.1.2.1.75.1.4.3.1.2)  
The number of Class 3 frames delivered through this FxPort to its attached  
NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class3FramesOut sent by a port.  
59047-09 C  
6-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Class 3 Accounting Table  
S
fcFxPortC3InOctets (1.3.6.1.2.1.75.1.4.3.1.3)  
The number of Class 3 frame octets, including the frame delimiters, received by  
this FxPort from its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class3WordsOut received by a port.  
fcFxPortC3OutOctets (1.3.6.1.2.1.75.1.4.3.1.4)  
The number of Class 3 frame octets, including the frame delimiters, delivered  
through this FxPort to its attached NxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
Return Value  
The total number of Class3WordsOut sent by a port.  
fcFxPortC3Discards (1.3.6.1.2.1.75.1.4.3.1.5)  
The number of Class 3 frames discarded by this FxPort.  
Syntax  
Counter32  
Access  
read-only  
Status  
current  
6-34  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Capability Group  
A
Return Value  
The total number of Class3Toss discarded by a port.  
Capability Group  
The objects described in this section are in table format indexed by switch index  
and port index. An example of how to access one of these objects is: "snmpget  
localhost public fcFxPortName.1.1". The Capability Group consists of a table  
describing information about what each FxPort is inherently capable of operating  
or supporting. A capability may be used as expressed in its respective object  
value in the Configuration group.  
fcFxPortCapFcphVersionHigh (1.3.6.1.2.1.75.1.5.1.1.1)  
The highest or most recent version of FC-PH that the FxPort is capable of  
supporting.  
Syntax  
FcphVersion  
Access  
read-only  
Status  
current  
Return Value  
Always returns 32 (0x20).  
fcFxPortCapFcphVersionLow (1.3.6.1.2.1.75.1.5.1.1.2)  
The lowest or earliest version of FC-PH that the FxPort is capable of supporting.  
Syntax  
FcphVersion  
Access  
read-only  
Status  
current  
Return Value  
Always returns 9.  
59047-09 C  
6-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Capability Group  
S
fcFxPortCapBbCreditMax (1.3.6.1.2.1.75.1.5.1.1.3)  
The maximum number of receive buffers available for holding Class 1  
connect-request, Class 2, or Class 3 frames from the attached NxPort.  
Syntax  
FcBbCredit  
Access  
read-only  
Status  
current  
Return Value  
The default is: 255 (0xFF).  
fcFxPortCapBbCreditMin (1.3.6.1.2.1.75.1.5.1.1.4)  
The minimum number of receive buffers available for holding Class 1  
connect-request, Class 2, or Class 3 frames from the attached NxPort.  
Syntax  
FcBbCredit  
Access  
read-only  
Status  
current  
Return Value  
The default is: 0 (0x00).  
fcFxPortCapRxDataFieldSizeMax (1.3.6.1.2.1.75.1.5.1.1.5)  
The maximum size in bytes of the Data Field in a frame that the FxPort is capable  
of receiving from its attached NxPort.  
Syntax  
FcRxDataFieldSize  
Access  
read-only  
Status  
current  
6-36  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Capability Group  
A
Return Value  
2112 (0x840).  
fcFxPortCapRxDataFieldSizeMin (1.3.6.1.2.1.75.1.5.1.1.6)  
The minimum size in bytes of the Data Field in a frame that the FxPort is capable  
of receiving from its attached NxPort.  
Syntax  
FcRxDataFieldSize  
Access  
read-only  
Status  
current  
Return Value  
128 (0x80).  
fcFxPortCapCos (1.3.6.1.2.1.75.1.5.1.1.7)  
A value indicating the set of classes of service that the FxPort is capable of  
supporting.  
Syntax  
FcCosCap  
Access  
read-only  
Status  
current  
Return Value  
Always returns Class F, 2, and 3 (0x0d).  
fcFxPortCapIntermix (1.3.6.1.2.1.75.1.5.1.1.8)  
A flag indicating whether or not the FxPort is capable of supporting the intermixing  
of Class 2 and Class 3 frames during a Class 1 connection. This flag is only valid  
if the port is capable of supporting Class 1 service.  
Syntax  
TruthValue  
59047-09 C  
6-37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Capability Group  
S
Access  
read-only  
Status  
current  
Return Value  
Always returns False (2).  
fcFxPortCapStackedConnMode (1.3.6.1.2.1.75.1.5.1.1.9)  
A value indicating the mode of Stacked Connect request that the FxPort is  
capable of supporting.  
Syntax  
FcStackedConnMode  
Access  
read-only  
Status  
current  
Return Value  
Always returns None (1).  
fcFxPortCapClass2SeqDeliv (1.3.6.1.2.1.75.1.5.1.1.10)  
A flag indicating whether or not the FxPort is capable of supporting Class 2  
Sequential Delivery.  
Syntax  
TruthValue  
Access  
read-only  
Status  
current  
Return Value  
Always returns true (1).  
fcFxPortCapClass3SeqDeliv (1.3.6.1.2.1.75.1.5.1.1.11)  
A flag indicating whether or not the FxPort is capable of supporting Class 3  
Sequential Delivery.  
6-38  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
6 – Fabric Element MIB Objects  
Capability Group  
A
Syntax  
TruthValue  
Access  
read-only  
Status  
current  
Return Value  
Always returns true (1).  
fcFxPortCapHoldTimeMaxv (1.3.6.1.2.1.75.1.5.1.1.12)  
The maximum holding time that the FxPort is capable of supporting, in  
microseconds.  
Syntax  
MicroSeconds  
Access  
read-only  
Status  
current  
Return Value  
20000 (0x4E20)  
fcFxPortCapHoldTimeMin (1.3.6.1.2.1.75.1.5.1.1.13)  
The minimum holding time that the FxPort is capable of supporting, in  
microseconds.  
Syntax  
MicroSeconds  
Access  
read-only  
Status  
current  
Return Value  
10 (0x0A)  
59047-09 C  
6-39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6 – Fabric Element MIB Objects  
Capability Group  
S
Notes  
6-40  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 QLOGIC MIB Objects  
This section covers the implementation details for the QLOGIC Management  
Information Bases (QLOGIC-MIB) on the SANbox switch.  
QLOGIC MIB Definitions  
This MIB replaces the fcFxPortPhysTable module defined in  
FIBRE-CHANNEL-FE-MIB, and defines volatile control objects for ports in a  
QLogic SANbox switch. If the switch gets reset, these values revert back to the  
default values in the configuration file.  
fcQxPortPhysAdminStatus (1.3.6.1.4.1.1663.1.3.10.1.1.3)  
The desired state of the FxPort. A management station may place the FxPort in a  
desired state by setting this object accordingly. The testing(3) state indicates that  
no operational frames can be passed. When a Fabric Element initializes, all  
FxPorts start with fcQxPortPhysAdminStatus in the offline(2) state. As the result of  
either explicit management action or per configuration information accessible by  
the Fabric Element, fcQxPortPhysAdminStatus is then changed to either the  
online(1) or testing(3) states, or remains in the offline state.  
Syntax  
INTEGER {  
online(1), - place port online  
offline(2), - take port offline  
testing(3) - initiate test procedures  
}
Access  
read-write  
Status  
current  
Return Value  
Refer to Table 7-1 for fcQxPortPhysAdminStatus read values.  
59047-09 C  
7-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
7 – QLOGIC MIB Objects  
QLOGIC MIB Definitions  
S
Table 7-1. fcQxPortPhysAdminStatus Read Return Values  
Port Value  
Online  
Offline  
online (1)  
offline (2)  
testing (3)  
offline (2)  
Diagnostics  
Down  
Refer to Table 7-2 for fcQxPortPhysAdminStatus write values.  
Table 7-2. fcQxPortPhysAdminStatus Write Values  
Port  
Value  
Online  
online (1)  
offline (2)  
testing (3)  
Offline  
Diagnostics  
fcQxPortPhysOperStatus (1.3.6.1.4.1.1663.1.3.10.1.1.4)  
The current operational status of the FxPort. The testing(3) indicates that no  
operational frames can be passed. If fcQxPortPhysAdminStatus is offline(2), then  
fcQxPortPhysOperStatus should be offline(2). If fcQxPortPhysAdminStatus is  
changed to online(1), then fcQxPortPhysOperStatus should change to online(1). If  
the FxPort is ready to accept Fabric Login request from the attached NxPort, it  
should proceed and remain in the link- failure(4) state if, and only if, there is a fault  
that prevents it from going to the online(1) state.  
Syntax  
INTEGER {  
online(1), - Login may proceed  
offline(2), - Login cannot proceed  
testing(3), - port is under test  
linkFailure(4) - failure after online/testing  
}
Access  
read-only  
Status  
current  
7-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
7 – QLOGIC MIB Objects  
Related Traps  
A
Return Value  
Refer to Table 7-3 for fcQxPortPhysOperStatus return values.  
Table 7-3. fcFxPortPHysOperStatus Return Values  
Status Return Value  
Online  
online (1)  
Offline  
offline (2)  
Diagnostic  
Down  
testing (3)  
linkfailure (4)  
Related Traps  
The following traps contain the trap information being sent from the agent to the  
manager.  
qlSB2PortLinkDown (qLogicExperimental 0 10)  
A linkDown trap signifies that the SNMP entity, acting in an agent role, has  
detected that the fcQxPortPhysOperStatus object for one of its communication  
links has left the online state and transitioned to some other state. The current  
state is indicated by the included value of fcQxPortPhysOperStatus.  
Variables:  
{ fcQxPortPhysAdminStatus, fcQxPortPhysOperStatus }  
qlSB2PortLinkUp (qLogicExperimental 0 11)  
A linkUp trap signifies that the SNMP entity, acting in an agent role, has detected  
that the fcQxPortPhysOperStatus object for one of its communication links has  
entered the online state from some other state. The current state is indicated by  
the included value of fcQxPortPhysOperStatus.  
Variables:  
{ fcQxPortPhysAdminStatus, fcQxPortPhysOperStatus }  
qlconnUnitAddedTrap (qLogicExperimental 0 12)  
A connUnit has been aded to this agent.  
Variables:  
{ connUnitId }  
59047-09 C  
7-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
7 – QLOGIC MIB Objects  
Related Traps  
S
Notes  
7-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 Firmware Download MIB  
Objects  
This section covers the implementation details for the Firmware Download  
Management Information Bases (FD-MIB) on the SANbox switch.  
Firmware Download MIB Definitions  
The FD-MIB enables you to download, install, and activate new firmware on  
QLogic SANbox switches using the Trivial File Transfer Protocol (TFTP). The  
downloaded firmware can be activated using a hot reset (non-disruptive) or a hard  
reset (disruptive).  
A hot reset is a Non-Disruptive Code Load Activation (NDCLA) operation. The  
firmware will be activated, the switch will be reset without a Power On Self Test,  
and switch traffic will not be disrupted. The switch does not need to be rebooted  
after the firmware is activated. During a hotreset operation, fabric services will be  
unavailable for a short period (30-75 seconds depending on switch model). To  
ensure that the NDCLA operation is successful, verify that all administrative  
changes to the fabric (if any) are complete. When you need to do NDCLA/hotreset  
to multiple switches, only perform the NDCLA/hotreset on one switch at a time,  
and wait 75 seconds before performing the NDCLA/hotreset operation on the next  
switch.  
A hard reset is a Normal (or regular) reset operation. The firmware will be  
activated, the switch will be reset with a Power On Self Test, and switch traffic will  
be disrupted. The switch must be rebooted after the firmware is activated.  
qlgcChFwOpResult (1.3.6.1.4.1.3873.3.1.1.2.1)  
The status of the last firmware download and/or installation attempt.  
Syntax  
OBJECT IDENTIFIER  
Access  
read-only  
59047-09 C  
8-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
8 – Firmware Download MIB Objects  
Firmware Download MIB Definitions  
S
Status  
Current  
Return Value  
Returns the following:  
DownloadNoError: 1.3.6.1.4.1.3873.3.1.1.1.1.1,  
DownloadHostError: 1.3.6.1.4.1.3873.3.1.1.1.1.2,  
DownloadFileError: 1.3.6.1.4.1.3873.3.1.1.1.1.3,  
InstallNoError: 1.3.6.1.4.1.3873.3.1.1.1.2.1,  
InstallFileError: 1.3.6.1.4.1.3873.3.1.1.1.2.2,  
InstallFileErrorNoAdmin: 1.3.6.1.4.1.3873.3.1.1.1.2.3,  
ResetNoError: 1.3.6.1.4.1.3873.3.1.1.1.3.1,  
ResetNoErr: 1.3.6.1.4.1.3873.3.1.1.1.3.2,  
ResetNoAdmin: 1.3.6.1.4.1.3873.3.1.1.1.3.3  
qlgcChFwOpRequest (1.3.6.1.4.1.3873.3.1.1.2.2)  
Starts the operation to download/install firmware, and/or reset the switch.  
Syntax  
INTEGER {  
(1) - auto (downloads, installs, and resets the switch)  
(2) - downloadOnly  
(3) - installOnly  
(4) - resetOnly  
}
Access  
read-write  
Status  
current  
qlgcChFwDwldHostAddrType (1.3.6.1.4.1.3873.3.1.1.2.3)  
The type of the IP address from which the firmware file is accessed.  
Syntax  
INTEGER  
Access  
read-write  
Status  
current  
8-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
8 – Firmware Download MIB Objects  
Firmware Download MIB Definitions  
A
qlgcChFwDwldHostAddr (1.3.6.1.4.1.3873.3.1.1.2.4)  
The IP address from which the firmware file is accessed.  
Syntax  
IP ADDRESS  
Access  
read-write  
Status  
current  
qlgcChFwDwldHostPort (1.3.6.1.4.1.3873.3.1.1.2.5)  
The port number (defaults is 69) used to transfer the firmware file.  
Syntax  
INTEGER  
Access  
read-write  
Status  
current  
qlgcChFwDwldPathName (1.3.6.1.4.1.3873.3.1.1.2.6)  
The full directory name on the server where the firmware file is located. If the  
firmware file to be downloaded is in a subdirectory, setting this path name to the  
name of that subdirectory is required.  
Syntax  
DisplayString  
Access  
read-write  
Status  
current  
qlgcChFwDwldFileName (1.3.6.1.4.1.3873.3.1.1.2.7)  
The filename of the firmware being transferred.  
Syntax  
DisplayString  
59047-09 C  
8-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
8 – Firmware Download MIB Objects  
Firmware Download MIB Definitions  
S
Access  
read-write  
Status  
current  
qlgcChFwResetMethod (1.3.6.1.4.1.3873.3.1.1.2.8)  
The value for the type of reset (hot reset or hard reset).  
Syntax  
INTEGER {  
(1) - Normal (disruptive)  
(2) - NDCLA (Non-Disruptive Code Load Activation)  
Access  
read-write  
Status  
current  
8-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
9 Maintenance Panel Health  
Check MIB Objects  
This section covers the implementation details for the Maintenance Panel (MP)  
MIB (QLGC-MP-MIB) on the SANbox 9000 switches. This MIB applies only to the  
SANbox 9000 switches.  
Maintenance Panel MIB Definitions  
The Maintenance Panel MIB allows you to monitor the health of the maintenance  
panel. This MIB consists of a single point status report object which reports the  
status of the EPROM (ok/alarm). It also defines a trap which will be reported if the  
status changes.  
qlgcMPStatus (1.3.6.1.4.1.3873.3.2.1.1.1)  
Represents the current status of eprom.  
Syntax  
Integer32  
Access  
ReadOnly  
Status  
Current  
Return Value  
ok (1)  
alarm (2)  
59047-09 C  
9-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
9 – Maintenance Panel Health Check MIB Objects  
Related Traps  
S
Related Traps  
The following trap relates the status of the MP health check status when the status  
changes state.  
qlgcMPStatusChange (1.3.6.1.4.1.3873.3.2.0.1)  
The status of the maintenance panel eprom monitor changed.  
Variables:  
{ qlgcMPStatus }  
9-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Glossary  
AL_PA  
Bit Error Rate  
The probability that a transmitted bit will be  
Arbitrated Loop Physical Address  
erroneously received. The BER is  
measured by counting the number of bits  
in error at the output of a receiver and  
dividing by the total number of bits in the  
transmission. BER is typically expressed  
as a negative power of 10.  
Arbitrated Loop  
A Fibre Channel topology where ports use  
arbitration to establish a point-to-point  
circuit.  
Arbitrated Loop Physical Address (AL_PA)  
Buffer Credit  
A unique one-byte value assigned during  
loop initialization to each NL_Port on a  
Loop.  
A measure of port buffer capacity equal to  
one frame.  
Abstract Syntax Notation (ASN.1)  
Class 2 Service  
Abstract Syntax Notation number One  
(ASN.1) is an international standard that  
specifies data used in communication  
protocols.  
A service that multiplexes frames at frame  
boundaries to or from one or more  
N_Ports wit h acknowledgment provided.  
Class 3 Service  
Authentication Trap  
A service that multiplexes frames at frame  
boundaries to or from one or more  
N_Ports without acknowledgment.  
Enables or disables the reporting of SNMP  
authentication failures. If enabled, a notifi-  
cation trap is sent to the configured trap  
addresses in the event of an authentica-  
tion failure. The default value is False.  
Contact  
Specifies the name of the contact person  
who is to be contacted to respond to trap  
events. The default is undefined.  
BER  
Bit Error Rate  
Datagram  
A message sent between two communi-  
cating entities for which no explicit link  
level acknowledgement is expected.  
Domain ID  
User defined name that identifies the  
switch in the fabric.  
59047-09 C  
Glossary-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SANbox Simple Network Management Protocol  
Reference Guide  
S
Fabric Management Switch  
IP  
The switch through which the fabric is  
managed.  
Internet Protocol  
ISLSecurity  
Flash Memory  
ISLSecurity determines which switches a  
port will establish a link with. ANY - we will  
link with any switch. Ours - we will only link  
to another QLogic switch. None - the port  
will not establish an ISL link.  
Memory on the switch that contains the  
chassis control firmware.  
Frame  
Data unit consisting of a start-of-frame  
(SOF) delimiter, header, data payload,  
CRC, and an end-of-frame (EOF) delim-  
iter.  
LCFEnable  
LCFEnable gives preference to Link  
control frames (such as Class 2 ACK  
frames) over other frames, when queued  
for transmission in the switch. This may  
provide better performance when running  
Class 2 traffic. LCFEnable is incompatible  
with MFSEnable, and both cannot be  
selected. (True / False)  
ICMP  
Internet Control Message Protocol  
IETF  
Internet Engineering Task Force  
Initiator  
LIP  
The device that initiates a data exchange  
with a target device.  
Loop Initialization Primitive sequence  
Location  
Specifies the switch location. The default  
Internet Engineering Task Force  
A large open international community of  
network designers, operators, vendors,  
and researchers concerned with evolution  
and smooth operation of the Internet, and  
responsible for producing RFCs. The  
standards body responsible for Internet  
standards, including SNMP, TCP/IP and  
policy for QoS.  
is undefined.  
Logged-In LED  
A port LED that indicates device login or  
loop initialization status.  
Management Information Base  
A set of guidelines and definitions for the  
Fibre Channel functions.The specification  
and formal description of a set of objects  
and variables that can be read and  
possibly written using the SNMP protocol.  
Various standard MIBs are defined by the  
Internet Engineering Task Force.  
Internet Control Message Protocol  
A control protocol strongly related to IP  
and TCP, and used to convey a variety of  
control and error indications.  
InteropCredit  
Management Workstation  
Port configuration parameter that adjusts  
the number of port buffer credits to allow  
interoperability with some non-QLogic  
switches.  
Workstation that manages the fabric  
through the fabric management switch.  
Glossary-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
MIB  
QoS  
Quality of Service  
Management Information Base  
MSEnable  
Determines whether GS-3 management  
POST  
Power On Self Test  
server commands will be accepted on the  
port. It can be used to prevent in-band  
management of the switch on any or all  
ports. (True / False)  
Power On Self Test (POST)  
Diagnostics that the switch chassis  
performs at start up.  
NL_Port  
Private Device  
Node Loop Port. A Fibre Channel device  
port that supports arbitrated loop protocol.  
A device that can communicate only with  
other devices on the same loop.  
N_Port  
Private Loop  
Node Port. A Fibre Channel device port in  
a point-to-point or fabric connection.  
A loop of private devices connected to a  
single switch port.  
NMS  
Read Community  
Network Management Station  
Read Community Authentication. A  
write-only field; the value on the switch  
and the SNMP management server must  
be the same. The default value is Public.  
Network Management Station  
The console through which an adminis-  
trator performs management functions.  
Request For Comment (RFC)  
NoClose  
Internet-related specifications, including  
standards, experimental definitions, infor-  
mational documents and best practice  
definitions, produced by the IETF.  
Causes the switch to keep the loop open,  
if no other device is arbitrating. It is  
intended to improve performance when  
there is a single L_Port device connected  
to the switch. (True / False).  
Enterprise Fabric Suite 2007  
Switch management application.  
Node  
SFF  
An addressable entity connected to an I/O  
bus or network. Used primarily to refer to  
computers, storage devices, and storage  
subsystems. The component of a node  
that connects to the bus or network is a  
port.  
Small Form-Factor transceiver.  
SFP  
Small Form-Factor Pluggable. A trans-  
ceiver device, smaller than a GigaBit Inter-  
face Converter, that plugs into the Fibre  
Channel port.  
Object  
In the context of access control, an entity  
to which access is controlled and/or usage  
of which is restricted to authorized  
subjects.  
59047-09 C  
Glossary-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Simple Network Management Protocol  
Trap Port  
The port number on which the trap is set.  
The protocol governing network manage-  
ment and that allows monitoring of network  
devices.  
Trap Severity  
Specifies a severity level to assign to the  
trap. Trap severity levels include  
SMI  
Structure of Management Information  
Unknown, Emergency, Alert, Critical, Error,  
Warning, Notify, Info, Debug, and Mark  
Small Form Factor  
UDP  
A transceiver device, smaller than a  
GigaBit Interface Converter, that is perma-  
nently attached to the circuit board.  
User Datagram Protocol  
User Datagram Protocol  
Small Form-Factor Pluggable  
An Internet protocol that provides connec-  
tion-less datagram delivery service to  
applications. Abbreviated UDP. UDP over  
Internet Protocol adds the ability to  
address multiple endpoints within a single  
network node to IP.  
A transceiver device, smaller than a  
GigaBit Interface Converter, that plugs into  
the Fibre Channel port.  
SNMP  
Simple Network Management Protocol  
VIEnable  
Structure of Management Information  
FC-VI. When enabled, VI preference  
frames will be transmitted ahead of other  
frames. (True / False)  
A notation for setting or retrieving manage-  
ment variables over SNMP.  
Target  
Worldwide Name (WWN)  
A storage device that responds to an initi-  
ator device.  
A unique 64-bit address assigned to a  
device by the device manufacturer.  
TCP  
Write Community  
Transmission Control Protocol  
Write Community Authentication. A  
write-only field; the value on the switch  
and the SNMP management server must  
be the same. The default value is Private.  
Trap Address  
Specifies the IP address to which SNMP  
traps are sent. The default is 127.0.0.1. A  
maximum of 5 trap addresses are  
supported.  
WWN  
Worldwide Name  
Trap Community  
Zone  
Trap Community Authentication. A  
A set of ports or devices grouped together  
to control the exchange of information.  
write-only field; the value on the switch  
and the SNMP management server must  
be the same. The default value is Public.  
Glossary-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
Zone Set  
A set of zones grouped together. The  
active zone set defines the zoning for a  
fabric.  
59047-09 C  
Glossary-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Notes  
Glossary-6  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
A
C
59047-09 C  
Index-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SANbox Simple Network Management Protocol  
Reference Guide  
S
connUnitPortStatCountLossofSynchronization  
connUnitPortStatCountNumberLinkResets  
connUnitPortStatCountNumberOfflineSequen  
connUnitPortStatCountPrimitiveSequenceProt  
connUnitPortStatCountRxBroadcastObjects  
connUnitPortStatCountRxMulticastObjects  
connUnitPortStatCountRxOfflineSequences  
connUnitPortStatCountClass1FBSYFrames  
connUnitPortStatCountClass1FRJTFrames  
connUnitPortStatCountClass1PBSYFrames  
connUnitPortStatCountClass1PRJTFrames  
connUnitPortStatCountClass2FBSYFrames  
connUnitPortStatCountClass2FRJTFrames  
connUnitPortStatCountTxBroadcastObjects  
connUnitPortStatCountTxMulticastObjects  
connUnitPortStatCountClass2PBSYFrames  
connUnitPortStatCountClass2PRJTFrames  
connUnitPortStatCountTxOfflineSequences  
connUnitPortStatCountEncodingDisparityError  
connUnitPortStatCountInvalidOrderedSets  
Index-2  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
F
D
E
59047-09 C  
Index-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Index-4  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
G
I
59047-09 C  
Index-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Q
R
S
L
M
N
P
Index-6  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
A
U
T
W
59047-09 C  
Index-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SANbox Simple Network Management Protocol  
Reference Guide  
S
Notes  
Index-8  
59047-09 C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 www.qlogic.com  
Europe Headquarters QLogic (UK) LTD. Quatro House Lyon Way, Frimley Camberley Surrey, GU16 7ER UK +44 (0) 1276 804 670  
D
© 2000-2008 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic, the QLogic logo, SANbox, SANblade, QuickTools, and Manage-  
ment Suite are trademarks or registered trademarks of QLogic Corporation. Gnome is a trademark of the GNOME Foundation Corporation. Java and Solaris are registered trademarks of Sun  
Microsystems, Inc. Linux is a registered trademark of Linus Torvalds. Mac OS X and Safari are registered trademarks of Apple Computer, Inc. Microsoft, Windows XP, Windows 2003, and  
Internet Explorer are trademarks of Microsoft Corporation. Netscape Navigator and Mozilla are trademarks or registered trademarks of Netscape Communications Corporation. Red Hat is a  
registered trademark of Red Hat Software Inc. SUSE is a trademark of Novell, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners. Infor-  
mation supplied by QLogic Corporation is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this publication. QLogic Corporation reserves the  
right, without notice, to make changes in product design or specifications.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Python Automobile Alarm 871XP User Guide
Rangemaster Ventilation Hood RMG2H60SS User Guide
Ricoh Camera Flash GF 1 User Guide
RocketFish Bluetooth Headset RF GPS31126 User Guide
Rosen Entertainment Systems Games G10 User Guide
Rosen Entertainment Systems GPS Receiver DS HD0820 User Guide
Sanyo Air Conditioner 12KHS71 User Guide
Sanyo Indoor Furnishings POA CH EX06 User Guide
Sanyo Projector PLV WF20 User Guide
Scion Stereo System PT546 00121 User Guide