Sanyo Air Conditioner 12KHS71 User Guide

Print Form  
Split System Submittal Data  
System: 12KHS71  
Indoor/Outdoor: KHS1271/CH1271  
Wall Mounted Heat Pump  
Job Name:  
Location:  
Approval:  
Date:  
Engineer:  
Construction:  
Unit #:  
Drawing #:  
Submitted to:  
Submitted by:  
Reference:  
General Data (at 115V)  
V/PH/Hz  
Power  
115/1/60  
Circuit Ampacity  
Fuse Size, Max.  
(A)  
(A)  
20  
20  
Refrigerant  
Lbs. - R410a (outdoor unit)  
Control  
R410A  
2.43  
Electric Expansion Valve  
Compressor  
No. used  
R.L. Amps - L.R.  
Crankcase Heater  
DC Rotary Inverter  
1
9.8/10.6-20  
20  
Flare  
65  
23  
Connection  
(A)  
(W)  
Line Length, Max (ft.)  
Lift Difference, Max (ft.)  
Line Size  
Outdoor Unit  
Fan type  
Dia. (in.) - No. Speeds  
Type Drive - No. Speeds  
No. Poles  
(in. O.D. Discharge)  
(in. O.D. Suction)  
1/4”  
3/8”  
Line Size  
Propeller  
15-3/4-1  
Direct - 3  
8-750  
Dimensions  
(in.)  
H x W x D  
Indoor Unit  
(RPM)  
(W)  
(Uncrated) 11-7/32 x 32-15/32 x 7-7/16  
No. Motors  
30-1  
(Crated)  
(Uncrated)  
(Crated)  
13-25/32 x 35-7/16 x 10-1/32  
21-9/16 x 28-11/32 x 10-7/16  
23-5/8 x 33-11/16 x 14-1/4  
(High)  
(A)  
1059  
0.6  
CFM  
F.L. Amps  
Outdoor Unit  
Aluminum Fin & Copper Pipe  
Corrugated Plate - Inner Rifed  
Coil Type  
Weight  
Net  
Shipping  
Indoor  
19.8  
24.3  
Outdoor  
77.2  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
(lbs.)  
(lbs.)  
2-18.1  
3.95  
5/16”  
83.8  
(sq.ft.)  
(in.)  
Tube Size  
Indoor  
2.82  
Outdoor  
6.36  
Shipping Volume  
(cu.ft.)  
Indoor Unit  
Fan type  
Dia. & Length (in.) - No. Speeds  
No. Speeds  
No. Poles  
No. Motors  
CFM  
Performance Data @ ARI Standard Conditions (230/208V)  
Cooling  
Cross Flow  
D3-11/6 L24-31/32-1  
3 & Auto  
Total Capacity  
Sensible Capacity  
Latent Capacity  
SEER  
(BTU/H)  
(BTU/H)  
(BTU/H)  
11,900 (3,000-11,900)  
(RPM, High)  
(W)  
(HI/Med/Lo)  
(Hi) (dB-A)  
(A)  
4-1250  
14.8-1  
294/259/212  
9,100  
2,800  
17  
4.26  
Indoor Sound Rating  
F.L. Amps  
Dehumidification  
Amps  
Power Inputs  
Outdoor Sound Rating  
(Pints/H)  
(A)  
(W)  
(dB-A)  
36  
0.346  
-/10.9 (2.5-10.9)  
-/1,090 (250-1,090)  
47  
Coil Type  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
Tube Size  
Aluminum Plate Fin & Copper Tube  
Slit Plate - Inner Rifed  
2-19.5  
Heating  
Total Capacity  
HSPF  
(sq.ft.)  
(in.)  
(in.)  
2.02  
9/32”  
23/32”  
(BTU/H) 14,300 (3,000-14,300)  
9.3  
Drain Connection Size  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Raritan Engineering Water System MCCAT116 User Guide
Ricoh Printer SP 112 User Guide
Rockford Fosgate Car Speaker FNP2414 User Guide
Rosewill Network Router RNX N150HG User Guide
Salter Housewares Scale SH6941 User Guide
Samsung Blu ray Player BDF7500 User Guide
Samsung Range FTQ386LWUX User Guide
Sanus Systems TV Mount VMPL2 User Guide
Sanyo VCR VHR H530 User Guide
Seagate Server 73LP User Guide