Wavelength  
(TX/RX)  
Model  
Connector  
Mode  
Distance  
C-1000MM-S1SC10U  
CM-1000MM-S1SC10U  
SC  
SM  
10 km/6.2 mi.  
1310/1490 nm  
1490/1310 nm  
C-1000MM-S1SC10D  
CM-1000MM-M2xx05  
SC  
SM  
10 km/6.2 mi.  
Note 2: Please refer the Perle web site for the most up to date  
Installation guides, models and specifications.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
The default switch settings (all switches in the UP position) will  
work for most installations. See the Operation section of this guide  
for more details.  
The module comes equipped with a bank of DIP switches and  
jumpers for setting configuration  
The default DIP switch settings (all switches in the UP position)  
and jumper setting will work for most installations.  
The following steps are used to configure the Perle Gigabit Fiber  
to Fiber Media Converter Module:  
1. Set the Auto-Config jumper. (CM-1000MM only) (optional)  
2. Set the DIP switch settings (optional).  
3. Insert the Media Converter Module into the chassis.  
4. Connect the fiber cables.  
Auto-Config Jumper (CM-1000MM only)  
The Auto-Config jumper is J5.  
Refer to the diagram below for labelling.  
Auto (Pin 2 and Pin 3 are strapped): When set to Auto the  
module will, at power-up, check its internal flash memory to see if  
configuration information has been downloaded to it from a  
management module. If so, it will use this as its running  
configuration. If there is no configuration in flash it will read the  
settings of the DIP switches and use those as its running  
configuration.  
SW: (Pin 1 and Pin 2 are strapped): When set to SW (Switch),  
the module will, at power-up, read the settings of the DIP Switches  
and use those as it running configuration. It will ignore any  
configuration information in its flash memory.  
NOTE: The default jumper setting is Auto  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIP Switch Settings  
Fiber Negotiation (Switch 1)  
Switch Position Mode  
Up (default)  
Down  
Auto  
Off  
Auto: In this mode of operation the Media Converter will negotiate  
fiber parameters on both MM1and MM2/SM2 (fiber ports). This will  
ensure the most optimal connection parameters will be in effect. If  
connecting to another Perle media converter, this parameter  
should be set to Auto.  
Off: Fiber negotiation on both fiber ports will be disabled. Fiber  
Negotiation should only be turned off, if the fiber link partner does  
not support fiber link negotiations.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Link Mode (Switch 2)  
Switch Position Mode  
Up (default)  
Down  
Smart Link Pass-Through Mode  
Standard Mode  
Smart Link Pass-Through: In this mode, the link state on one  
connection is directly reflected through the Media Converter to the  
other connection. If link is lost on one of the connections, then the  
other link will be brought down.  
Standard Mode: In this mode the links can be brought up and  
down independently of each other. A loss of link on either fiber  
connection can occur without affecting the other connection.  
Fiber Fault Alert (Switch 3)  
Switch Position Mode  
Up (default)  
Down  
Enabled  
Disabled  
Enabled: If the media converter module detects a loss of fiber  
signal on the fiber receiver, the media module will immediately  
disable its fiber transmitter signal on this port. This, in effect,  
notifies the fiber link partner that an error condition exists on the  
fiber connection.  
If the remote media converter module is set up for Fiber Fault  
Alert(FFA) Enabled and the local media converter is set up with  
Smart Link Pass-Through, a loss of fiber link on either the transmit  
or receive line will be passed through to the other fiber connection.  
Disabled: The media converter module will not monitor for fiber  
fault.  
Note: This feature is not required; if Fiber negotiation has been  
enabled since link negotiation accomplishes the same thing. When  
Fiber Negotiation is enabled this switch is ignored.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Illustration of the FFA  
Media Converter A Configuration  
Link Mode–Standard Mode  
Fiber Fault Alert  
Media Converter B Configuration  
Link Mode–Smart Link Pass Through Mode  
Fiber Fault Alert  
Sequence of Events  
1. Media Converter  
A
A
B
loses fiber connection (RX) on MM2/SM2.  
disables the transmitter (TX) MM2/SM2.  
detects loss of fiber link on receiver RX –  
2. Media Converter  
3. Media Converter  
MM2/SM2.  
4. Media Converter  
5. Media Converter  
B
A
turns off transmitter (TX) on MM1.  
MM1 is not affected  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Loopback Fiber 1 (Switch 4)  
Switch Position Mode  
Up (default)  
Down  
Disabled  
Enabled  
Disabled: The loopback feature is disabled. This is the normal  
position for regular operation. The switch must be set to this  
position in order for data to pass through the Media Converter  
Module.  
Enabled: This is a test mode. All data received on the receive  
(RX) fiber connection is looped back to the transmit (TX) fiber  
connection.  
Note: Only one fiber interface can be in loopback at a time.  
Remote Loopback Fiber 2 (Switch 5  
Switch Position Mode  
Up (default)  
Down  
Disabled  
Enabled  
Disabled: The loopback feature is disabled. This is the normal  
position for regular operation. The switch must be set to this  
position in order for data to pass through the Media Converter  
Module.  
Enabled: This is a test mode. All data received on the receive  
(RX) fiber connection is looped back to the transmit (TX) fiber  
connection.  
Note: Only one fiber interface can be in loopback at a time.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing Media Converter Modules  
Caution: Observe electrostatic discharge precautions when  
installing the Media Converter Module(s) into the Chassis. Failure  
to observe this caution could result in damage to the Module(s)  
and/or chassis.  
The Perle Media Converter Modules can be installed in any  
available slot and in any order within the chassis.  
1. Remove the Module from its packaging.  
2. Using a cross-head screwdriver, remove the screw holding the  
face plate to the Chassis to reveal the slot opening.  
3. Set the jumpers and DIP switches on the Media Converter  
Module to the desired operating mode.(optional)  
4. Locate the top and bottom alignment guides inside the MCR  
Chassis.  
5. Using the module alignment guides gently slide the module  
into the slot until it becomes flush with the front of the Chassis.  
Light pressure may be needed to seat the module. Do not  
force the module as you might cause damage. If there is  
resistance, remove the module and check the module  
connector for damaged or incorrectly aligned pins. If these are  
not damaged, retry module insertion.  
6. Tighten the captive retainer screw to ensure the Media  
Converter Module is locked in place.  
7. Remove the dust cap from the fiber connector and connect the  
fiber and copper cables.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing Media Convert Modules  
1. Loosen the captive retainer screw on the front of the Media  
Converter Module and gently pull the module out.  
2. If not inserting a replacement Media Converter Module then  
cover the opening slot with a face plate and secure the screw.  
Installing the Duplex Fiber Cable  
1. Locate a 1000Base-X compliant duplex (2 strands) fiber cable  
with appropriate connectors.  
2. Connect the fiber cables from one Converter to the other  
Converter/switch/fiber device ensuring that the RX and TX are  
reversed at the opposite end.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Simplex Fiber Cable  
1. Locate a 1000Base-X compliant simplex (1 strand) fiber cable  
with appropriate connectors.  
2. Connect the fiber cable from one Converter to the other  
Converter/switch/fiber device.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Status LED  
The Perle Gigabit Media Converter Modules have three single  
colored status LEDs located on the face plate of the module.  
PWR - Power/Test  
On: Power is on, module is operating normally.  
Blinking slowly: the module is in loopback mode.  
Blinking quickly: the module has a hardware error.  
LK1- MM1 (Fiber Link10) Activity  
On: Fiber link present.  
Blinking quickly: Fiber link present and receiving data.  
Blinking slowly: The fiber link has been taken down as a  
result of Smart Link Pass-Through  
Off: No fiber link.  
LK2- MM2/SM2 (Fiber Link 2) Activity  
On: Fiber link present.  
Blinking quickly: Fiber link present and receiving data.  
Blinking slowly: The fiber link has been taken down as a  
result of Smart Link Pass-Through.  
Off: No fiber link.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
General  
Ensure the module is securely seated in the chassis. The  
PWR LED on the module should be on solid.  
Ensure all cabling is of the correct type and is in good  
operating condition.  
Ensure both devices on either end of the fiber are compatible.  
If using a simplex fiber connection, ensure that you have both  
an Upstream (U) and Downstream (D) Media Converters.  
For dual-stranded fiber connections, ensure the RX and TX  
has been reversed between the two Media Converters.  
No connectivity  
If unable to get full connectivity with all DIP switches in the UP  
position, these methods are recommended for troubleshooting.  
Method 1  
1. Turn off Fiber Negotiation (SW1 Down) on both media  
converters. Leave all other switches UP.  
2. Connect the near end device to port MM1, the LK1 LED  
should be lit to indicate a good fiber connections. If the LK1  
LED is not lit, then check the fiber cable and the attached  
device.  
3. Repeat step 2 for port MM2/SM2.  
4. Return the media converter to the desired configuration.  
Method 2:  
The fiber connection can also be verified by configuring the remote  
media converter for loopback mode. The LEDs on both media  
converters should be lit. Data should pass through the local  
converter then over the fiber connection to the remote media  
converter.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: If troubleshooting a CM-1000MM, setting the Auto-Config  
jumper (J5) to SW will ensure the DIP switches are being read.  
Technical Specifications  
The following applies to all C-1000MM and CM-1000MM media  
converters:  
Power Input/Consumption  
Operating Temperature:  
Storage Temperature:  
Operating Humidity:  
Storage Humidity:  
12V DC /2.5 W  
0°C - 50°C (32°F - 122°F)  
-25°C - 70°C (-13°F - 158°F)  
5% to 90% non-condensing  
5% to 95% non-condensing  
Up to 3,048 m (10,000 ft)  
0.15 kg (0.33 lbs)  
Operating Altitude:  
Weight:  
MTBF: (C-1000MM)  
MTBF: (CM-1000MM)  
421,344 hours  
417,722 hours  
Fiber Optic Specifications:  
Fiber port 1 – MM1  
Wave  
length  
(nm)  
TX  
Power  
(dB)  
RX  
Power  
(dB)  
Budget  
(dB)  
Model  
Mode  
C-1000MM-M2SC05  
CM-1000MM-M2SC05  
TX: 850  
RX: 850  
Min: -9.5 Min: -17  
MM  
7.5  
Max: -4  
Max: -3  
Fiber port 2 – MM2/SM2  
Wave  
length  
(nm)  
TX  
Power  
(dB)  
RX  
Power  
(dB)  
Budget  
(dB)  
Model  
Mode  
C-1000MM-M2SC05  
CM-1000MM-M2SC05  
TX: 850  
RX: 850  
Min: -9.5 Min: -17  
Max: -4 Max: -3  
MM  
MM  
MM  
SM  
7.5  
C-1000MM-M2ST05  
CM-1000MM-M2ST05  
TX: 850  
RX: 850  
Min: -9.5 Min: -17  
Max: -4 Max: -3  
7.5  
C-1000MM-M2LC05  
CM-1000MM-M2LC05  
TX: 850  
RX: 850  
Min: -9.5 Min: -17  
Max: -4 Max: -3  
7.5  
C-1000MM-S2SC10  
CM-1000MM-S2SC10  
TX: 1310  
RX:1310  
Min: -9.5 Min: -20  
Max: -3 Max: -3  
10.5  
10.5  
C-1000MM-S2ST10  
CM-1000MM-S2ST10  
TX: 1310  
RX:1310  
Min: -9.5 Min: -20  
Max: -3 Max: -3  
SM  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C-1000MM-M2LC10  
CM-1000MM-M2LC10  
TX: 1310  
RX:1310  
Min: -9.5 Min: -20  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
SM  
10.5  
20  
20  
20  
21  
23  
23  
32  
32  
32  
11  
11  
Max: -3  
Max: -3  
C-1000MM-S2SC40  
CM-1000MM-S2SC40  
TX: 1310  
RX:1310  
Min: -3  
Max: 5  
Min: -23  
Max: -3  
C-1000MM-S2ST40  
CM-1000MM-S2ST40  
TX: 1310  
RX:1310  
Min: -3  
Max: 5  
Min: -23  
Max: -3  
C-1000MM-S2LC40  
CM-1000MM-S2LC40  
TX: 1310  
RX:1310  
Min: -3  
Max: 2  
Min: -23  
Max: -3  
C-1000MM-S2SC70  
CM-1000MM-S2SC70  
TX: 1550  
RX:1550  
Min: -2  
Max: 5  
Min: -23  
Max: -3  
C-1000MM-S2ST70  
CM-1000MM-S2ST70  
TX: 1550  
RX:1550  
Min:  
Max: 5  
0
Min: -23  
Max: -3  
C-1000MM-S2LC70  
CM-1000MM-S2LC70  
TX: 1550  
RX:1550  
Min:  
Max: 5  
0
Min: -23  
Max: -3  
C-1000MM-S2SC120  
CM-1000MM-S2SC120  
TX: 1550  
RX:1550  
Min:  
Max: 5  
0
Min: -32  
Max: -9  
C-1000MM-S2ST120  
CM-1000MM-S2ST120  
TX: 1550  
RX:1550  
Min:  
Max: 5  
0
Min: -32  
Max: -9  
C-1000MM-S2LC120  
CM-1000MM-S2LC120  
TX: 1550  
RX:1550  
Min:  
Max: 5  
0
Min: -32  
Max: -9  
C-1000MM-S1SC10U  
CM-1000MM-S1SC10U  
TX: 1310  
RX:1490  
Min: -9  
Max: -3  
Min: -20  
Max: -3  
C-1000-S1SC10D  
CM-1000-S1SC10D  
TX:1490  
RX:1310  
Min: -9  
Max: -3  
Min: -20  
Max: -3  
Fiber Cabling Requirements:  
MM: 50/125 microns or 62.5/125 microns  
SM: 9/125 microns  
Note: Please refer the product page on the Perle website for the  
most up to date models and specifications.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance Information  
FCC  
This product has been found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated  
in a commercial environment. This equipment generates, uses, and can radiate  
radio frequency energy and, if not installed and used in accordance with the  
instructions in this Guide, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful  
interference, in which case the user will be required to correct the interference at  
his/her own expense.  
EN 55022, Class A,  
WARNING This is a Class A product. In a domestic environment this product may  
cause radio interference in which case the user may be required to take adequate  
measures.  
EN 55024, Class A  
Laser Safety – IEC 60825-1:2007  
This product meets Class I Laser safety requirements per IEC-60825-1:2007  
standard and complies with FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11.  
WARNING: Visible and invisible laser radiation may be present when cables are  
not connected. Do not stare into the beam or view the beam directly with optical  
instruments. Failure to observe this warning could result in an eye injury or  
blindness.  
WARNING: Use of controls, adjustments or the performance of procedures other  
than those specified herein may result in hazardous radiation exposure.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty / Registration  
Perle’s standard Lifetime Warranty provides customers with return  
to factory repairs for Perle products that fail under the conditions of  
the warranty coverage. Details can be found at:  
Contacting Technical Support  
Contact information for the Perle Technical Assistance Center  
(PTAC) can be found at the link below. A Technical Support Query  
may be made via this web page.  
Copyright  
© 2011 Perle Systems Limited  
All rights reserved. No part of this document may be reproduced or used in any form  
without written permission from Perle Systems.  
Gigabit Fiber to Fiber Media Converter Module – Installation Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peg Perego Stroller aria on track User Manual
Philips Baby Accessories SCF660 27 User Manual
Philips Universal Remote SBC RU 880 User Manual
Philips Work Light 66704 30 16 User Manual
Planet Technology Network Router ADE 3400v3 User Manual
Porter Cable Air Compressor CPF6025VP User Manual
Poulan Snow Blower 428863 User Manual
ProForm Home Gym 831285840 User Manual
ProForm Treadmill 625 EX User Manual
PYLE Audio Car Video System PLD 169U User Manual