Paradyne Modem 3811PLUS User Manual

TM  
COMSPHERE 3811Plus Modem  
Installation Instructions  
Document Number 3980-A2-GZ41-20  
June 1998  
4. When installed in the final configuration, the  
product must comply with the applicable Safety  
Standards and regulatory requirements of the  
country in which it is installed. If necessary,  
consult with the appropriate regulatory agencies  
and inspection authorities to ensure compliance.  
User’s Guide  
This document provides basic installation instructions  
for the COMSPHERE 3811Plus (Model 3981) modem.  
For complete configuration and operation instructions,  
refer to the COMSPHERE 3800Plus Modems Users  
Guide (Document Number 3980-A2-GB30).  
In addition, if the equipment is to be used with  
telecommunications circuits, take the following  
precautions:  
Contact your local sales representative, service  
representative, or distributor directly for any help needed.  
For additional information concerning warranty, sales,  
service, repair, installation, documentation, training,  
distributor locations, or Paradyne worldwide office  
locations, use one of the following methods:  
Never install telephone wiring during a lightning  
storm.  
Never install telephone jacks in wet locations  
unless the jack is specifically designed for wet  
locations.  
Via the Internet: Visit the Paradyne World Wide  
Never touch uninsulated telephone wires or  
terminals unless the telephone line has been  
disconnected at the network interface.  
Via Telephone: Call our automated call system to  
receive current information via fax or to speak with a  
company representative.  
Use caution when installing or modifying telephone  
lines.  
Within the U.S.A., call 1-800-870-2221  
Outside the U.S.A., call 1-727-530-2340  
Avoid using a telephone (other than a cordless type)  
during an electrical storm. There may be a remote  
risk of electric shock from lightning.  
Important Safety Instructions  
Do not use the telephone to report a gas leak in the  
vicinity of the leak.  
1. Read and follow all warning notices and  
instructions marked on the product or included in  
the manual.  
Government Requirements  
2. Slots and openings in the cabinet are provided for  
ventilation. To ensure reliable operation of the  
product and to protect it from overheating, these  
slots and openings must not be blocked or  
covered.  
Notice to Users of the United States Public  
Switched Telephone Network  
1. This equipment complies with Part 68 of the FCC  
rules. On the equipment is a label that contains,  
among other information, the FCC registration  
number and ringer equivalence number (REN) for  
this equipment. The label is located on the circuit  
card assembly of the 3811Plus. If requested, this  
3. General purpose cables may be provided with this  
product. Special cables, which may be required by  
the regulatory inspection authority for the  
installation site, are the responsibility of the  
customer.  
3980-A2-GZ41-20  
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
This modem is suitable for connection to BT circuits  
with signalling at a nominal frequency of 2280 Hz and  
may be connected to multipoint or point-to-point circuits.  
The apparatus does not require signalling or otherwise use  
the frequency range 0200 Hz.  
CAUTION  
Users should not attempt to  
make such connections  
themselves, but should  
contact the appropriate  
electric inspection authority,  
or electrician, as appropriate.  
No d.c. interaction is intended between the modem and  
the telephone network.  
This apparatus may be directly connected to a  
speechband circuit or connected to a relevant branch  
system for speechband circuits.  
The Load Number for this equipment is on the label on  
the modem. The Load Number (LN) assigned to each  
terminal device denotes the percentage of the total load to  
be connected to a telephone loop which is used by the  
device to prevent overloading. The termination on a loop  
may consist of any combination of devices subject only to  
the requirement that the total of the Load Numbers of all  
devices does not exceed 100.  
All European Countries  
Safety Notice  
Interconnection circuits between this modem and any  
other equipment should be such that the equipment  
continues to comply with the requirements of EN41003  
for TNV (Telephone Network Voltage) circuits and  
EN60950 for SELV (Safety Extra Low Voltage) circuits  
after making connection between circuits.  
United Kingdom  
Ringer Equivalence Number  
The Ringer Equivalence Number (REN) is a customer  
guide indicating approximately the maximum number of  
items of apparatus that should be connected  
simultaneously to the telephone line. The sum of the  
RENs should not exceed four. This value includes any  
BT-provided instrument which may be assumed to have a  
REN of 1 unless marked otherwise. The REN of this  
modem is 1.  
Japan  
Notices  
Connection to Leased Lines  
If any other apparatus, including cable or wiring, is  
connected between the apparatus and the point of  
connection to any speechband circuit, then all that other  
apparatus shall comply with the following:  
This equipment is classified in the 1st Class  
category. When used in a residential area or  
in an adjacent area thereto, radio  
interference may be caused to radios and  
TV receivers, etc. VCCI-1  
1. The overall transmission characteristics of all that  
other apparatus shall be such as to introduce no  
material effect upon the electrical conditions  
presented to one another by the apparatus and the  
speechband circuit; and  
2. All that other apparatus shall comprise only:  
Restrictions  
(i) apparatus approved for the purpose of  
connection between the apparatus and a  
speechband circuit; and  
Due to JATE (Japan Approvals Institute for  
Telecommunications Equipment) regulations, only three  
attempts to dial a number are permitted in a 3-minute  
period. If a fourth attempt is made to dial the same  
number, the modem returns the ERROR return code. This  
restriction applies to the number dialed from the  
(ii) cable or wiring complying with a code of  
practice for the installation of equipment covered  
by this part of BS 6328 or such other requirements  
as may be applicable.  
3980-A2-GZ41-20  
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
command line or from a directory. An occurrence of the  
restriction is canceled when a different number is dialed,  
or when three minutes have elapsed.  
Installation  
Customer-Supplied Equipment  
The 3811Plus modem (see Figure 1) is designed for  
installation in a COMSPHERE 3000 Series Carrier which  
supplies operating power and the dial-line and/or  
leased-line network connections. For power, dial-line,  
leased-line, Network Interface Module (NIM), and  
network management cabling information, refer to the  
COMSPHERE 3000 Series Carrier Installation Manual  
(Document Number 3000-A2-GA31).  
Equipment Warranty and  
Support  
Technical Support  
Contact your local sales representative, service  
representative, or distributor directly for any help needed.  
For additional information concerning warranty, sales,  
service, repair, installation, documentation, training,  
distributor locations, or Paradyne worldwide office  
locations, use one of the following methods:  
In addition to the carrier, the following  
customer-supplied equipment may be required for the  
installation of a 3811Plus modem:  
A Shared Diagnostic Unit (SDU, required for  
network management applications and multiple  
carriers).  
Via the Internet: Visit the Paradyne World Wide  
A Shared Diagnostic Control Panel (SDCP).  
Via Telephone: Call our automated call system to  
receive current information via fax or to speak with  
a company representative.  
One 6-position to 6-position modular cord (required  
for network management applications).  
Two 50-pin mass termination cables, one NIM for  
modems installed in Slots 1–8, and one NIM for  
modems installed in Slots 9–16 (required for  
dial-line applications).  
— Within the U.S.A., call 1-800-870-2221  
— From outside the U.S.A., call 727-530-2340  
One of the following dial or leased network  
interfaces:  
Equipment Service  
After opening the modem’s package, check for damage  
and verify that the following items are present:  
— 50-pin to modular cable (RJ11C) for dial  
permissive applications  
3811Plus modem  
— 50-pin to modular cable (JM8) for leased line  
applications  
Rear connector plate with DB-25-P edge card  
connector  
An RS-232 DTE cable with a DB25 connector at  
one end and a connector appropriate to your DTE at  
the other end.  
Examine the equipment carefully upon arrival. If there  
is an obvious defect or you experience trouble please  
contact your sales or service representative (as  
If the modem is to be managed by a network  
management system, an SDU must be supplied and  
properly connected to the network management controller.  
For proper network management connection to the SDU,  
refer to the appropriate network management system  
user’s guide.  
appropriate) for repair or warranty information. If the  
product needs to be returned to the company service  
center for repair, contact them directly for return  
instructions using one of the following methods:  
Via the Internet: Visit the Paradyne World Wide  
Via Telephone: Call our automated call system to  
receive current information via fax or to speak with  
a company representative.  
— Within the U.S.A., call 1-800-870-2221  
— From outside the U.S.A., call 727-530-2340  
4
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3980-A2-GZ41-20  
Rear  
Connector  
Plate  
EIA232/V.24  
Connector  
Faceplate  
EIA232/V.24  
Status  
Edge Card  
Connector  
Pwr  
Alrm  
Test  
Dial  
RI  
142  
125  
Busy  
Serv  
SQ  
103  
104  
105  
106  
107  
108  
109  
TXD  
RXD  
RTS  
CTS  
DSR  
DTR  
LSD  
Front Panel  
Spkr  
Unused  
3811Plus  
496-14488-02  
Figure 1. 3811Plus Modem  
3980-A2-GZ41-20  
June 1998  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
The COMSPHERE 3000 Series Carrier has 17 slots  
which can hold up to 16 modems and one SDU. The SDU  
is required when the modems in the carrier are controlled  
by an NMS, or when multiple carriers in a cabinet  
configuration are to be controlled by a single SDCP. The  
SDCP of the COMSPHERE 3000 Series Carrier is the  
user interface to the 3811Plus modem. A single SDCP can  
control modems in up to eight carriers.  
To install a 3811Plus modem into the carrier, perform  
the following steps.  
" Procedure  
1. At the rear of the carrier, install the rear connector  
plate. Make sure the plate uses the same slot  
position as that intended for the modem.  
25-Pin  
DTE Connectors  
495-14797  
.42  
EAI32/V  
2. At the front of the carrier, hold the modem  
vertically, with the latch on its faceplate in the  
open position, and insert it into the top and bottom  
card guides of one of the slots numbered 1–16.  
(830)  
(
Slide the modem into the slot, aligning the modem  
with the rear connector plate, until the backplane  
connector and DTE connector seat firmly into the  
back of the carrier. To lock the modem into the  
carrier, press the faceplate latch until a click is  
heard.  
.52  
.53  
V
R3S6A/V  
P21  
496-14906  
Loosely fasten the plate. This allows for slight  
adjustments later when installing the modem.  
CAUTION  
Always use a ground strap  
when handling a modem.  
Always store a 3811Plus  
modem in an antistatic bag  
when it is removed from the  
carrier.  
6
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3980-A2-GZ41-20  
3. Rotate the circuit pack lock(s) into the closed  
position, and tighten the screw.  
Check the SDCP  
If an SDCP is installed, verify that the SDCP can be  
used to control the modem. Perform the following steps.  
Circuit  
Pack  
Lock  
Carrier Slots 1–16  
SDU  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
Select  
OK Alarm BckUp Test EC  
F1  
F2  
F3  
COMSPHERE 3000  
Keypad  
Circuit  
Closed  
Status  
Indicators  
LCD  
Select  
Key  
Card  
Display  
(Locked)  
Guides  
496-12348a-03  
" Procedure  
1. Press the  
key on the SDCP. The cursor  
Select  
Open  
(Unlocked)  
appears in the two-digit slot selection entry.  
2. Press the  
key to position the cursor on the  
two-digit carrier selection entry.  
3. Press the F1 () or F2 () key until the carrier  
Latch  
495-14813  
number you want appears on the LCD.  
The carrier number selection has a range of 1 to 8.  
With an SDU installed, a single SDCP can control  
up to eight carriers.  
4. If the carrier is connected to power, the Power  
LED on the faceplate of the 3811Plus lights up.  
After several seconds the modem completes its  
power-up self-test in which all faceplate LEDs  
light up.  
4. Press the  
key to position the cursor on the slot  
selection entry.  
If the modem fails, or an alarm condition exists,  
the Alrm LED on the faceplate lights up or  
flashes. It may be possible to run a diagnostic  
self-test from the SDCP. See Test Branch in the  
COMSPHERE 3800Plus Modems Users Guide.  
5. Press the F1 () or F2 () key until the slot  
number (1–16) you want appears on the LCD.  
(Ignore the AB designator that appears on the  
LCD since it is not applicable to the 3811Plus  
modem.)  
Return to the rear of the carrier and tighten the  
rear connector plate.  
The Front Panel LED on the modem’s faceplate  
lights up.  
5. Connect an RS-232D DTE cable to the top  
connector of the rear connector plate. (The bottom  
connector is unused.)  
6. Press the  
key to place the SDCP in direct  
Select  
communication with the selected modem.  
The LCD displays the Top-Level menu for the  
selected modem.  
6. Connect the other end of the cable to your DTE.  
7. Configure the modem as described in the  
following section, Select Factory Configuration  
Options.  
3980-A2-GZ41-20  
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
5. Press the  
key until the appropriate factory  
Select Factory Configuration  
Options  
preset appears on the LCD, and press the  
corresponding function key to select your choice.  
If you select Sync Leased, a new prompt asks you  
to select Answer Mode (F1) or Originate Mode  
(F3). Press the appropriate key.  
After the modem passes the power-up self-test,  
configure it for operation using one of the factory preset  
configurations.  
The 3811Plus modem has several factory preset  
templates that contain the proper configuration options  
(straps) for different environments. Modems are shipped  
from the factory with the Async Dial default configuration  
options stored in memory. To prepare the modem for Sync  
Dial, Sync Leased, UNIX Dial, Cellular (Mobile), or  
Cellular (PSTN), you must change the factory setting,  
using either the SDCP or the AT command &Fn, as  
described in the following sections.  
6. Choose Function now appears and displays the  
Edit and Save functions.  
7. Press the F3 key (Save).  
The LCD displays Sav EditArea to.  
8. The Active (Saved), Customer 1, and Customer 2  
configuration areas are nonvolatile memory  
locations. Active (Saved) contains the most  
recently saved changes to any configuration  
options. In the event of power loss, the modem  
retrieves these configuration options.  
The Cellular (Mobile) and Cellular (PSTN) settings  
(and the analogous AT commands &F5 and &F6) are  
available only if Enhanced Throughput Cellular (ETC )  
is installed.  
Press the F1 key to select Active (Saved). The  
LCD displays Command Complete.  
Configuring a Modem Using the SDCP  
9. The modem is now configured with the selected  
To change a factory template from the Async Dial  
preset configuration using the SDCP, perform the  
following steps.  
factory template. Press the  
the Top-Level menu.  
key to return to  
" Procedure  
Configuring a Modem Using AT Commands  
1. Press the  
key on the SDCP. Use the  
Select  
When using AT commands, the following criteria must  
be met:  
function keys to enter the carrier number and slot  
number of the modem to be configured. Press the  
key again. The Front Panel LED of the  
selected modem lights up.  
Select  
Make sure the asynchronous DTE’s communication  
software is configured for 10-bit character format  
(including the start bit); for example, 8 data bits, no  
parity, and 1 stop bit.  
2. Press the  
view.  
key until Configure comes into  
Make sure the DTE (RS-232D) cable is attached to  
the DTE connector on the rear of the  
COMSPHERE 3000 Series Carrier, and the correct  
serial communications port on the asynchronous  
DTE.  
Idle : 28.8  
Test  
Configure  
F3  
F1  
F2  
On initial power-up, the modem is in Command  
mode. To verify that the modem is connected and  
functioning properly, enter the following:  
3. Press the function key below Configure to select  
the Configure branch.  
TYPE: AT  
PRESS: Return (Enter)  
The screen displays OK.  
The LCD now displays Ld EditArea frm.  
4. Press the  
key until Factory comes into view,  
then press the F1 key to display the factory preset  
configurations.  
8
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3980-A2-GZ41-20  
To change a factory template using AT commands,  
perform the following steps.  
Menu Structure  
The menu tree accessible from the SDCP contains the  
following branches:  
" Procedure  
1. Enter the appropriate factory configuration  
command (&Fn) followed by the &W0 command  
to store the configuration in Active (Saved) and  
the Z command to reset the modem.  
Call Setup  
Status  
Used to dial, disconnect, and  
answer telephone calls as well  
as store up to 10 telephone  
numbers in directory locations.  
TYPE: AT&Fn&W0Z  
Used to monitor the current  
status of the VF line and DTE  
interface as well as view the  
identity of the modem.  
Where: n is one of the following Factory  
configurations:  
0 is Async Dial  
1 is Sync Dial  
2 is Sync Leased (Answer Mode)  
3 is UNIX Dial  
4 is Sync Leased (Originate Mode)  
5 is Cellular (Mobile)  
6 is Cellular (PSTN)  
Test  
Used to begin and end various  
modem tests.  
Configure  
Used to change and save the  
modem’s configuration  
options.  
Control  
Remote  
Security  
Used to control the modem’s  
hardware and software  
functions.  
PRESS: Return (Enter)  
2. The selected factory configuration is saved and the  
modem is reset.  
Used to access and control a  
remote 3800Plus series  
modem.  
Synchronous factory preset configurations (&F1, &F2,  
and &F4) inhibit AT command control. To regain AT  
command control, you must use the SDCP to load a  
different factory preset configuration.  
Used to control the modem’s  
dial access security. Appears  
only if the optional security  
feature is installed.  
The AT commands &F5 and &F6 are available only if  
Enhanced Throughput Cellular (ETC) is installed.  
The following pages show the general menu structure  
of the SDCP displays. The model, installed features, and  
configuration options all may affect what is actually  
displayed at each level of the menus.  
3980-A2-GZ41-20  
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Displays current status of modem along with  
data rate and error control mode.  
“Status”  
Status  
to next page  
Call_Setup  
Test  
Dial  
Answer  
Change_Directory  
Disconnect  
Dial_Standby  
or  
Return_to_Dial  
VF  
DTE  
SDC  
Options Record  
Identity  
RX  
Ser#  
Mod #  
FRev  
HPt#  
FPt#  
LSD  
DTR  
DSR  
Tst  
TXD  
RXD  
RTS  
CTS  
No Signal SigQual  
RcvLev  
TX  
Display  
Clear  
Directory Locations 1 – 10  
Sig/Noise  
NearEcho  
FarEcho  
FarEchDel  
EchoFreqOff  
Does not appear in Remote Mode.  
(Rem_Digital_Loop, Loc_Digital_Loop, and  
Pattern appear if the secondary channel is  
used.)  
Some choices within this group may not  
appear depending upon how previous  
configuration options have been selected.  
Abort  
Self  
Rem_Digital_Loop  
Pattern  
Appears only if SDC is installed.  
Loc_Digital_Loop  
Loc_Analog_Loop  
to next page  
DTE_Interface  
DTE_Dialer  
Line_Dialer  
AutoAnswerRing#  
Dialer Type  
Dial_Line  
Modulation  
Async/Sync Mode  
Async DTE Rate  
Sync DTE Rate  
#Data Bits  
Parity Bit  
#Stop Bits  
DTR Action  
DSR Control  
RTS Action  
CTS Control  
RTS/CTS Delay  
LSD Control  
DTE Dialer Type  
AT Escape Char  
Escape GuardTim  
BreakForceEscap  
CommandCharEcho  
CarriageRtn Char  
Backspace Char  
Linefeed Char  
Dial Line Rate  
Automode  
Autorate  
Dial TX Level  
V22b Guard Tone  
Train Time  
Asymmetric Rate  
Proactive Retrain  
Fall Fwd Delay  
DialTone Detect  
Blind Dial Paus  
BusyTone Detect  
"," Pause Time  
NoAnswer Timout  
Fast Disconnect  
Long Space Disc  
No Carrier Disc  
No Data Disc  
NoDataDiscTrig  
Auto Make Busy  
MakeBusyViaDTR  
DTR Auto Redial  
MI/MIC Dialing  
Result Codes  
ExtendResltCode  
ResultCode Form  
V25bis Coding  
TX Clock Source  
CT111_Rate Cntl  
DTE_Rate = VF  
V25bis IdleFill  
V.25b NewLineChr  
AT Cmnd Mode  
DTR Cont Repeat  
98-14528a-03  
10  
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3980-A2-GZ41-20  
from previous page  
to next page  
Configure  
Ld EditArea frm:  
Activ (Operating)  
Customer2  
Customer1  
Factory  
Async_Dial  
Sync_Leased  
Choose Mode  
Cellular  
(PSTN)  
Active (Saved)  
Sync_Dial  
UNIX_Dial  
Cellular  
(Mobile)  
Answer  
Originate  
Choose Function  
Edit  
Save  
Active (Saved) Customer1  
Customer2  
from previous page  
Leased_Line  
Leased Mode  
Modulation  
LeasedLine Rate  
Autorate  
Leased TX Level  
Bad Ln Auto Orig  
Rate Auto Orig  
Auto Redial  
AutoDialStandby  
CarrierOn Level  
V.29 TrainOnData  
Asymmetric Rate  
Fall Fwd Delay  
V42/MNP/Buffer  
Err Contrl Mode  
Sync Comp Mode  
SDC Negotiation  
SDC Idle Fill  
SDC BitEncoding  
SyncDTE CRC  
SDC Delay Min  
Sync Flow Cntrl  
V42bis Compress  
MNP5 Compress  
EC Negotiat Bfr  
EC Fallbck Char  
Flw Cntl of DTE  
Flw Cntl of Mdm  
XON/XOFF Psthru  
Mdm/Mdm FlowCtl  
Break Buffr Ctl  
Test  
Misc  
StrapsWhenDisc  
Speaker Control  
Speaker Volume  
Access frm Remt  
RemAccssPasswrd  
Dir#1_Callback  
NetMngmtAddress  
NMS_Call_Msgs  
NMS DTR Alarm  
NetworkPosition  
CellulrRJ11Adpt  
Security  
DTE RL (CT140)  
DTE LL (CT141)  
Test Timeout  
Rcv Remote Loop  
V54 Address  
V54 Device Type  
EntryWait_Time  
VF_Prompt_Type  
#DTE_PW_Tries  
DTE_PW_TermChar  
DTE_PW_BkSpChar  
Get_User_ID  
NMS_Reporting  
Answer_Secur  
Originate_Secur  
Does not appear if configured for  
Synchronous mode  
Only appears if Sync_Leased factory  
template is selected.  
Send Break Cntl  
[SDC Options]  
Tx Buff Disc Delay  
Rx Buff Disc Delay  
Max Frame Size  
Cellular Enhance  
BfrSizeInBfrMode  
Some choices within this group may  
not appear depending upon how previous  
configuration options have been selected.  
Some choices within this group appear  
only if optional features are installed.  
98-14528b-03  
3980-A2-GZ41-20  
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
from previous page  
Control  
Remote  
Security  
Secondary  
Prim (data blckd)  
(ExitRem appears  
instead of Remote when  
using Remote Mode)  
Set_Access_Ctrl  
(Admin Password?)  
Reset_Security  
EditPassWdTable  
Set_Orig_Secur  
Set_Admin_PsWd  
Set_Answer_Sec  
Speaker  
Make_Busy  
or  
Download Code  
RemoveMakeBusy  
Reset  
Service_Line  
or  
DiscServLine  
Does not appear in Remote Mode.  
(Rem_Digital_Loop, Loc_Digital_Loop, and  
Pattern appear if the secondary channel is  
used.)  
98-14528c-03  
*3980-A2-GZ41-20*  
*3980–A2–GZ41–20*  
Copyright E 1998 Paradyne Corporation  
12  
June 1998  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3980-A2-GZ41-20  

Miele Convection Oven h 4331 User Manual
Miele Convection Oven H 4784 BP User Manual
Navman Marine Radio MCB 7270 User Manual
NETGEAR Network Card WN511T User Manual
Oki Printer PAGE 6E User Manual
Omron Heart Rate Monitor HR 310 User Manual
Onkyo Stereo Amplifier A 9755 User Manual
Panasonic Answering Machine KX TD612E User Manual
Panasonic Fax Machine KX FC241AL User Manual
Panasonic Telephone Accessories KX TS560MX User Manual