INDIVIDUAL DATA SHEETS
For standby power supplies. Expected trickle life: Approx. 6 years at
25°C, Approx. 10 years at 20°C.
LC-P0612P
Dimensions (mm)
Terminal type: Faston 187 or Faston 250 with hole
1.5
0.5
+
-
1.5
0.5
+
50
16
151
-
130.3
Labels will vary, see page 73 for example of labels.
150.2
49.2
Battery case resin: Flame-retardant (UL94V-0)
Specifications
Discharge characteristics (25°C)(Note)
Nominal voltage
Rated capacity (20 hour rate)
Length
6V
12Ah
151 mm
50 mm
94 mm
100 mm
2 kg
Width
Height
7.2
6.9
6.6
6.3
6.0
5.7
5.4
5.1
4.8
4.5
4.2
3.9
Dimensions
Total Height
Approx. mass
* The total height of #250 teminal is 101.5mm.
1.2A
0.6A
20
3A
6A
12A
24A
20
Characteristics
0
1
2
4
6
8 10
(Minute)
Duration of discharge
40 60
2
4
6
8 10
40
20 hour rate (600mA)
12.0Ah
11.3Ah
10.4Ah
8.1Ah
(Hour)
10 hour rate (1130mA)
5 hour rate (2080mA)
1 hour rate (8100mA)
1.5 hour rate discharge
Cut-off voltage 5.25 V
Capacity(note)
(25°C)
5.8A
Duration of discharge vs. Discharge current (Note)
Fully charged battery
(25°C)
Internal resistance
Approx. 15mΩ
30
Temperature
dependency
of capacity
40°C
25°C
0°C
102%
100%
85%
20
15
(20 hour rate)
-15°C
65%
10
Residual capacity
after standing 3 months
Residual capacity
after standing 6 months
Residual capacity
after standing 12 months
91%
40˚C
5
4
Self discharge
(25°C)
82%
3
25˚C
64%
2
Charge
Method
(Constant
Voltage)
1.5
Initial current
1.8 A or smaller
0˚C
Trickle use
1
6.8V to 6.9V
(per 6V cell 25°C)
50
Control voltage
40
-15˚C
30
(Note) The above characteristics data are average values obtained within
three charge/discharge cycles, not the minimum values.
20
(Note) For cycle use of the battery, please contact us in advance.
10
5
3
300 500
(mA)
1
3
5
10
30
50
100
(A)
Discharge current
Sealed Lead-Acid Batteries
58
Download from Www.Somanuals.com. All Manuals Search And Download.
|