1.
2.
Procedure
3.
Indicates that a step-by-step procedure follows.
REFERENCE
Indicates where you can find additional information on the subject at hand.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
GN Series Hardware Manual
Table of Contents
1.1 Safety Instructions ..................................................................................... 2
1.2 Overview.................................................................................................... 4
1.3 Electrostatic Discharge (ESD) ................................................................... 5
1.3.1 Grounding Methods....................................................................................5
1.4 FCC Statement.......................................................................................... 6
1.5 Electromagnetic Compatibility ................................................................... 7
2.1 Product Parts........................................................................................... 10
3.1 All Views .................................................................................................. 14
3.2 Front View................................................................................................ 16
3.2.1 USB Interface on the Front ......................................................................16
3.2.2 Front Plates..............................................................................................17
3.2.3 Display with Touch Screen.......................................................................17
3.2.4 Calibrating the Touch Screen...................................................................17
iii
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
GN Series Hardware Manual
3.3 Bottom View .............................................................................................23
3.3.1 Optional Interfaces ...................................................................................23
3.3.2 DC Power Connector ...............................................................................25
3.3.4 VGA Interface Connector .........................................................................25
3.3.5 Reset Button.............................................................................................26
3.3.6 Status LEDs .............................................................................................26
3.4 Top View ..................................................................................................27
3.4.1 Compact Flash Card Slot .........................................................................27
3.5 Left and Right Side View..........................................................................28
3.6 Rear View.................................................................................................30
3.7 Single-Board Computer............................................................................32
3.8.1 DC Power Plug.........................................................................................33
3.10.2 Replacing the Lithium Battery ..................................................................41
4.1 General Specifications .............................................................................44
4.2 Environmental Specifications ...................................................................46
4.3 Dimensions...............................................................................................47
4.3.1 Front Views ..............................................................................................47
4.3.2 Rear and Right Side Views ......................................................................49
4.4 Pin Assignments.......................................................................................52
iv
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
Table of Contents
4.4.2 USB Interfaces.........................................................................................52
4.4.3 RS232 (COM1, COM2)............................................................................52
4.4.5 RS422/RS485 Configured as RS485 (4-Wire Mode), Full Duplex, Bus
Master ......................................................................................................53
4.4.7 VGA Port (VGA).......................................................................................54
4.4.8 DC Power Connector ...............................................................................54
4.5 Cables...................................................................................................... 55
v
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Introduction
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
GN Series Hardware Manual
1.1 Safety Instructions
WARNING
To ensure safe operation, observe these safety instructions.
!
I
•
•
Always take precautions to ensure the overall safety of your system so that the whole
system remains safe in the event of failure of this product or other external factor.
DO NOT USE THE PROGRAMMABLE DISPLAY TO CONTROL SAFETY
FEATURES OR OTHER CRITICAL OPERATIONS OF EQUIPMENT OR SYSTEMS.
A COMMUNICATION ERROR (FOR ANY REASON) MIGHT PREVENT SUCH
SAFETY FEATURES OR CRITICAL OPERATIONS FROM FUNCTIONING
PROPERLY.
•
•
Do not use this product in areas with inflammable gas. It could lead to an explosion.
Exposing this product to excessive heat or open flames could damage the lithium
battery or other electronic parts.
•
•
•
The on-site electrical installation must meet the requirements of the country’s specific
local regulations.
If a power cable comes with the product, only this cable should be used. Do not use
an extension cable to connect the product.
To guarantee that sufficient air circulation is available to cool the product, please
ensure that the ventilation openings are not covered or blocked. If a filter mat is
provided, this should be cleaned regularly.
•
•
Do not place the system close to heat sources or damp places.
Only devices or parts which fulfill the requirements of SELV circuits (Safety Extra Low
Voltage) as stipulated by IEC 60950-1 may be connected to the available interfaces.
NOTE
ꢀ
Opening the device during the guarantee period will render the guarantee null
and void.
•
Before opening the device, make sure that the device is disconnected from the mains.
Switching off the device by its power button does not disconnect it from the mains.
Complete disconnection is only possible if the power cable is removed from the wall
plug or from the device. Ensure that there is free and easy access to enable
disconnection.
•
If the system is expanded, you must observe the following:
-
-
that all effective legal regulations and all technical data are adhered to
the power consumption of any add-on card does not exceed the specified
limitations
2
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
1.1 Safety Instructions
-
the current consumption of the system does not exceed the value stated on the
product label.
•
Switch off and ensure that the device cannot be operated if the following apply
because safe operation may no longer be possible:
-
-
the device has visible damages or
the device is no longer functioning
Additional safety instructions for DC power supply circuits
•
To guarantee safe operation of devices with DC power supply voltages greater than 60V DC or a power
consumption larger than 240VA, please observe that:
-
the device is set up, installed and operated in a room or enclosure marked with
“RESTRICTED ACCESS” if there are no safety messages on the device itself
such as safety signs or labels.
-
no cables or parts without insulation in electrical circuits with dangerous voltage or
power should be touched directly or indirectly
-
-
a reliable protective earthing connection is provided
a suitable, easily accessible disconnecting device is used in the application (e.g.
overcurrent protective device) if the device itself cannot be disconnected
-
-
a disconnect device, if provided in or as part of the equipment, shall disconnect
both poles simultaneously
interconnecting power circuits of different devices cause no electrical hazards
•
•
A sufficient dimensioning of the power cable wires must be selected – according to the
maximum electrical specifications on the product label – as stipulated by EN60950-1
or EN60204 or UL508 regulations.
The devices do not generally fulfill the requirements for “centralized DC power
systems” (UL 60950-1, Annex NAB; D2) and therefore may not be connected to such
devices!
3
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
GN Series Hardware Manual
1.2 Overview
The GN series touch panels are human-machine interfaces (HMIs) designed for demanding
industrial applications such as installation in an instrument panel or switching cabinet.
NOTE
ꢀ
All versions are suitable for installation in an instrument panel or switching
cabinet. Use the mounting clamps included with the product.
The GN series includes:
•
•
•
•
GN07, 7" display
GN10, 10.4" display
GN12, 12.1" display
GN15, 15" display
In front of the display there is a touch screen that also protects the display surface from dirt
and scratches. The system is suitable for operation in harsh industrial environments.
The GN is equipped with interfaces such as 1x serial COM1 (RS232), 2x LAN (10/100/1000
Mbps), 2x USB (2.0), 1x VGA. Additional interfaces can be installed as follows:
•
The GN10/GN12/GN15 can be expanded with up to two different modules for
RS422/485 industrial fieldbus interfaces and/or an additional serial port COM2 as
RS232.
•
The GN07 can be expanded with one module for the RS422/485 or an industrial
fieldbus interface or an additional serial port COM2 as RS232.
The GN is designed to be connected to a +24V DC power supply using the DC power plug
(included).
NOTE
ꢀ
The GN series touch panels are designed to fulfill the IP65 degree of protection
for the front side. However, the USB connector on the front (if present) must be
covered by the elastic captive rubber coat.
The GN is a fanless system. The cooling of the unit is performed by ventilation holes in the
housing. The ventilation holes are located at the sides of the device and provide air circulation
in order to prevent the system from overheating.
NOTE
ꢀ
When powering on the GN, make sure that the ventilation holes are not
obstructed.
4
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
1.3 Electrostatic Discharge (ESD)
1.3 Electrostatic Discharge (ESD)
A sudden discharge of electrostatic electricity can destroy static-sensitive devices or
micro-circuitry. Proper packaging and grounding techniques are necessary prerequisites for
avoiding damage. Always take the following precautions:
•
•
Transport printed circuit boards in static-safe containers such as boxes or bags.
Keep electrostatic sensitive parts in their containers until they arrive at a static-free
station.
•
•
Always be properly grounded when touching a sensitive printed-circuit board,
component, or assembly.
Store electrostatic-sensitive printed-circuit boards in protective packaging or on
conductive foam.
1.3.1 Grounding Methods
Guard against electrostatic damage of the device by taking the following preventative steps:
•
Cover workstations with approved anti-static material. Provide a wrist strap connected
to a work surface and properly grounded tools and equipment.
•
•
Use anti-static mats, heel straps, or air ionizers for added protection.
Handle electrostatic-sensitive components, PCBs, and assemblies by the case or the
edge of the board.
•
•
Avoid contact with pins, leads, or circuitry.
Turn off power and input signals before inserting and removing connectors or test
equipment.
•
•
•
Keep the work area free of non-conductive materials such as ordinary plastic
assembly aids and Styrofoam.
Use field service tools, such as cutters, screwdrivers, and vacuum cleaners that are
conductive.
Always lay drives and PCBs with the component-side down on the foam.
5
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
GN Series Hardware Manual
1.4 FCC Statement
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in residential area
is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense. This Class A digital apparatus complies with the Canadian
ICES-003.
6
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
1.5 Electromagnetic Compatibility
1.5 Electromagnetic Compatibility
This product has been designed for industrial use. The most recent version of the EMC
guidelines (EMC Directive 2004/108/EC) and national laws apply. If the user modifies and/or
adds to the equipment (e.g. installation of add-on cards), the prerequisites for the CE conformity
declaration (safety requirements) may no longer apply.
7
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
GN Series Hardware Manual
1.6 Applicable Directives and Standards
Applicable directives for the CE mark
Low Voltage Directive (Electrical Safety)
EMC Directive
2006/95/EC
2004/108/EC
Electrical safety
Standards
EUROPE
EN 60950-1: 2006
USA / Canada
CB Scheme
UL 60950-1: 2006 cULus Listed
CB Certification
EMC
Standards
EN 61000-3-2:2006
EN 61000-3-3:2006
Limits - Limits for harmonic current emissions (equipment
input current <= 16 A per phase)
Limitation of voltage changes, voltage fluctuations and
flicker in public low-voltage supply systems, for equipment
with rated current <=16 A per phase and not subjected to
conditional connection
EUROPE
Generic standards - Emission standard for residential,
commercial and light-industrial environments (Emission):
EN 61000-6-3: 2007
Emission of Information technology equipment – Radio
disturbance characteristics – Limits and methods of
measurement
EN 55022/B: 2006
Generic standards - Immunity for industrial environments
(Immunity): EN 61000-6-2: 2005
U.S.A.
FCC 47 CFR Part 15, Class A
ICES-003
Canada
8
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Scope of Delivery
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Scope of Delivery
GN Series Hardware Manual
2.1 Product Parts
The system comes with the following parts:
Item
Description
GN system in the configuration ordered:
•
•
•
•
GN07
GN10
GN12
GN15
Phoenix power plug
Stylus (touch pen)
4 x mounting clamp with Allen screws for the GN07
8 x mounting clamp with Allen screws for the GN10
6 x mounting clamp with Allen screws for the GN12
8 x mounting clamp with Allen screws for the GN15
10
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
2.2 Type Label and Product Identification
2.2 Type Label and Product Identification
Product name
AIGN07xxxx
AIGN10xxxx
AIGN12xxxx
AIGN15xxxx
Product identification
GN07 (system with a 7" display)
GN10 (system with a 10.4" display)
GN12 (system with a 12.1" display)
GN15 (system with a 15" display)
The xxxx stands for the system configuration ordered, which depends on the application, e.g.
Machine Vision. The inspection status label and the type label (product name, serial number)
are located on the rear of the device (see page 30).
11
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3
Product Description
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
3.1 All Views
The pictures show a GN10.
Bottom view
Right view
Front view
Top view
Left view
14
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.1 All Views
Rear view
15
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
3.2 Front View
NOTE
ꢀ
The GN07 is not equipped with a USB interface on the front.
1
2
3
Typical front view
1
Front plate
2
3
TFT display with touch screen (glass-to-glass technology)
Covered USB interface
3.2.1 USB Interface on the Front
NOTE
ꢀ
•
•
The GN series touch panels are designed to fulfill the IP65 degree of
protection for the front side. However, the USB connector on the front (if
present) must be covered by the elastic captive rubber coat.
The GN07 is not equipped with a USB interface on the front.
This USB 2.0 interface allows you to connect different USB-compatible devices to the GN
series. The USB connector is covered by an elastic captive rubber coat. The rubber coat
prevents the penetration of fluids when no device is connected.
16
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.2 Front View
3.2.2 Front Plates
All versions are suitable for installation in an instrument panel or switching cabinet. The
material used for the front plate differs depending on the system:
•
•
GN07: zinc-coated steel plate painted RAL9011 (black)
Others: aluminum front plate with polyester front foil
Dimensions (mm)
GN07
GN10
GN12
GN15
Front plate (W x H)
235 x 168
157 x 95.8
348 x 277
380 x 312
449.4 x 354
Display (W x H)
214.2 x 161.2
295 x 234 x 44
248 x 186.5
306 x 230
Rear side enclosure (W x H x D)
215 x 146.2 x
45.7
324 x 263 x 49.5
406.4 x 311 x 50
3.2.3 Display with Touch Screen
touch screen (glass-glass technology). A stylus is supplied for touch screen operation.
The surface of the display is also mechanically protected by the touch screen. The touch
screen (USB connected) registers contacts of a finger or a pen and allows you to move the
mouse pointer. This works only if the necessary software is installed. You receive the touch
screen driver for your operating system installed on your system.
NOTE
ꢀ
•
•
Do not use a hard or a pointed object (like screw drivers) to operate the
touch screen because this can damage the touch screen surface.
The front panel (GN10/GN12/GN15) and the touch screen are covered by a
plastic overlay. Be careful when cleaning the plastic overlay (see page 22).
3.2.4 Calibrating the Touch Screen
Calibration serves two purposes:
•
•
Sets the active area of the touch screen.
Aligns the active area of the touch screen to the screen's image.
NOTE
ꢀ
Before you calibrate the touch screen, let the system warm up for 30 minutes.
Calibration aligns the active touch-sensitive area of the touch screen with the image on the
display. Calibration also determines the edges of the screen's image and locates the center of
the touch screen. If the touch screen is not calibrated properly, the active area of the touch
17
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
screen may not be aligned with the screen's image or may be unnecessarily small in size. If
you need to access the calibration routine, use a USB mouse.
The touch screen of your GN system is factory calibrated. Run the calibration routine when an
alignment problem exists between the mouse pointer and the stylus contact location on the
screen. You can adjust the touch screen calibration with the software "Hampshire TSHARC
Control Panel".
Depending on the operation system installed, the calibration procedure is slightly different.
3.2.4.1 Calibration under Windows® XP
To calibrate the system under Windows® XP, please proceed as follows:
1.
2.
Procedure
3.
1. Start → Programs → Hampshire TSHARC Control Panel
The following screen will appear:
18
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.2 Front View
2. Select the "Calibration" tab
3. Select [Configure] to set up calibration
4. Select the number of calibration points and offset
5. Select [OK]
19
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
6. Select [Test]
7. When prompted, touch the panel at the location indicated
8. Select [Accept]
REFERENCE
For more information about touch screen calibration, see the Hampshire®
TSHARC™ UniWinDriver™ Users Manual for Windows® XP.
20
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.2 Front View
3.2.4.2 Calibration under Windows® XP Embedded
To calibrate the system under Windows® XP Embedded, please proceed as follows:
1.
2.
Procedure
3.
1. Double-click the icon "hwincal.exe" on the desktop
This starts the calibration program C:\Program Files\tsharc\hwincal.exe.
Link to hwincal.exe
The following screen appears.
21
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
2. Touch the center of each target as accurately as possible
REFERENCE
For more information about touch screen calibration, see the Hampshire®
TSHARC™ UniWinDriver™ Users Manual for Windows® XP.
3.2.5 Touch Screen Care and Cleaning
For cleaning we recommend a mild detergent and water. Do not use of strong solvents, which
could attack paint or plastic. Protect the plastic overlay and the touch screen surface from
direct heat sources such as cigarettes. The display front is sealed against dust, liquids, etc.
The front surface of the touch screen is a flexible plastic foil. Avoid touching it with sharp
objects such as a knife, a pen or a pencil tip. Sharp objects can permanently damage the
functionality of the touch screen. Units without a touch screen have a polycarbonate shield,
which may be scratched if an object is sufficiently sharp.
22
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.3 Bottom View
3.3 Bottom View
Bottom view of the GN10/GN12/GN15
Status LED, storage medium
Status LED, system
Optional interfaces*
COM1 (RS232)
VGA
DC power connector
Grounding
screw
24V DC
N.C.
COM 1
USB
VGA
LAN 0
LAN 1
2 x LAN 2 x USB Power button
Reset button
Mounting clamp
with Allen screw
Mounting clamp
with Allen screw
*Optional interfaces: RS422/485 (insulated), industrial fieldbus, industrial Ethernet...
Bottom view of the GN07
Status LED, storage medium
Optional interface*
COM1 (RS232)
Power button
VGA
Status LED, system
DC power connector
Grounding
screw
24V DC
N.C.
LAN 0
LAN 1
USB
COM 1
VGA
2 x LAN
2 x USB
Reset button
Mounting clamp
with Allen screw
Mounting clamp
with Allen screw
*Optional interface: RS422/485 (insulated), industrial fieldbus...
3.3.1 Optional Interfaces
Three optional interfaces are available:
•
•
•
Industrial fieldbus
Industrial Ethernet (not GN07)
Depending on your requirements, GN10/GN12/GN15 supports up to two optional interfaces;
GN07 supports one.
3.3.1.1 RS422/RS485 Serial Interface
The optional RS422/485 serial interface is available as a Sub-D 9-pin connector (female). The
interface can be configured via DIP switches (see tables).
23
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
RS485 mode communication can be either in full-duplex or half-duplex mode. While running in
RS485 half duplex mode, the system stays in receiver mode. Switching to transmission mode
occurs automatically and is triggered by the RTS line or the last sent message using the TxD
line, which the user defines.
•
RTS: the RTS signal must be activated by the application software before starting the
data packet transmission The RTS signal has to be disabled again afterdata
transmission has been terminated.
•
TxD: the receiver device has to wait a certain time (timeout) before starting to send
any data.
ON
1
2
3
4
5
6
7
8
Default DIP switch settings
DIP switch (SW1) settings. Factory settings are marked in gray.
Serial communication
type
Switch from transmitting to SW1 settings
receiving mode
DIP1
DIP2
DIP3
RS422 4-channel mode
-
-
OFF
ON
OFF
OFF
OFF
ON
RS485 4-wire mode (Bus
Master)
RS485 2-wire mode
RS485 2-wire mode
RTS
ON
ON
ON
ON
ON
Timeout
OFF
Termination resistor for RS422 and RS485
SW1 settings
DIP4
Deactivated
Activated
OFF
ON
Timeout
Min. baud rate
SW1 settings
DIP5
DIP6
DIP7
DIP8
10.2ms
9.6ms
1200
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
9.0ms
8.4ms
7.8ms
7.2ms
6.5ms
5.9ms
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
4.8ms
4.3ms
2400
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
24
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.3 Bottom View
Timeout
Min. baud rate
SW1 settings
DIP5
DIP6
DIP7
DIP8
3.7ms
3.1ms
ON
ON
OFF
OFF
ON
ON
OFF
ON
2.5ms
1.9ms
4800
ON
ON
ON
ON
OFF
OFF
OFF
ON
1.2ms
0.6ms
9600
ON
ON
ON
ON
ON
ON
OFF
ON
19200
3.3.2 DC Power Connector
DC power connector
GN unit.
3.3.3 LAN0 and LAN1 Ethernet Interface Connectors
These interface connectors are provided as RJ45 sockets with integrated LEDs.
Ethernet port
LAN0
Data transfer rate
10/100/1000 Mbps
10/100/1000 Mbps
LAN1
Ethernet LED States:
Left LED state
Link activity state
Right LED state
Link speed
10 Base-T
Off
Green
Link active
Green
Yellow
100 Base-T
1000 Base-T
3.3.4 VGA Interface Connector
An external (analog) monitor can be plugged into this Sub-D 15-pin socket.
25
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
3.3.5 Reset Button
To restart the GN unit e.g. after a system hang-up, press the reset button with a pen, for
example. The system restarts automatically; you do not have to switch the computer off and
on.
NOTE
ꢀ
During a reset, all data in the main memory is erased.
3.3.6 Status LEDs
Status LED, storage medium (HDD/CF)
LED
Green
Red
Status
CF activity.
HDD activity.
Status LED, system
LED
Status
Green
Orange
The system is running.
The system is in standby.
Orange blinks 4 times
Off
Battery is improperly connected. Switch the +/- pole.
The system is disconnected from the power source.
NOTE
ꢀ
•
•
Use an isolating switch to turn the DC power supply on and off.
The GN unit is only completely disconnected from the DC main power
supply when the DC power cord is disconnected either from the power
supply or the unit. Therefore, the DC power cord and its connectors must
always remain easily accessible.
3.3.7 Grounding Screw (M4) with Lock Washers
The housing of the GN unit must be grounded by establishing a large-area contact between
the grounding screw M4x19 (DIN7985) with 2 x lock washer M4 (DIN6797) and an appropriate
grounding connection point. The minimum cross section of the grounding conductor is 1mm2
(AWG 18).
26
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.4 Top View
3.4 Top View
Mounting clamp
with Allen screw
Mounting clamp
with Allen screw
CF card slot
CF card eject button
Top of the GN10/12/15
Mounting clamp
with Allen screw
Mounting clamp
with Allen screw
CF card slot
CF card eject button
Top of the GN07
NOTE
ꢀ
•
•
The GN07 system does not have mounting slots on the top.
When powering up the system, make sure that the air intake and exhaust
openings are not obstructed.
3.4.1 Compact Flash Card Slot
The system is equipped with a compact flash (CF) card slot and only accepts CF cards type I.
NOTE
ꢀ
•
•
Before installing or removing the CF card, the GN unit must be powered
down and disconnected from the power supply.
The GN10/GN12/GN15 is equipped with an angled metal cover in order to
cover the card slot if no CF card is inserted. If a CF card is inserted, the
cover can be mounted in the "safe-keeping" location. The GN07 does not
have an angled metal cover for the CF card slot.
27
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
3.5 Left and Right Side View
1 2
2
1
3
3
4
6
4
7
6
5
5
6
6
6
6
Right side of a GN10
Left side of a GN10
28
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.5 Left and Right Side View
1
1
3
3
6
6
4
4
6
6
Right side of a GN07
Left side of a GN07
1
2
3
4
5
6
7
Front panel of the system with seal on the rear
Enclosure of the display
System cover
Type label
Screws that secure the cover on the left and right side
Mounting slots with installed mounting clamp and Allen screw
"Safe-keeping" location for the angled metal cover of the CF slot if a CF card is inserted (the cover is not
used for the GN07)
29
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
3.6 Rear View
1
2
3
4
5
3
6
3
3
3
3
3
3
Rear of the GN10
30
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.6 Rear View
1
2
4
3
3
3
3
Rear of the GN07
1
2
3
4
5
6
Front panel of the system with seal at the rear side
Type label
Mounting clamp and Allen screw for mounting to a subframe
System cover
Cover for the CF card slot ("safe keeping" location, if a CF card is inserted)
CF card slot and CF card eject button
31
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
3.7 Single-Board Computer
The GN unit is equipped with a single-board computer based on Intel® Atom™ Processor.
32
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.8 Connecting the System to the Power Supply
3.8 Connecting the System to the Power Supply
CAUTION
•
•
Attach the power cable last!
Before using your system, you should first become familiar with the system
components and check that everything is connected properly.
3.8.1 DC Power Plug
The GN panels are delivered with a DC power plug (3-pin Phoenix connector), which you
need to prepare.
NOTE
ꢀ
The length of the wires connected to the DC power connector may not exceed
10m.
1
2
3
DC power plug
1
2
3
Cover for terminal screws
"-" wire terminal
"+" wire terminal
1.
2.
3.
Procedure
1. Cut the two isolated wires [AWG18 (Ø up to 1mm2)] to the required length
2. Strip each end 5 – 7mm
7mm
3. Apply wire end ferrules
33
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
4. Lift the cover, for example with a screwdriver, to access the terminal screws
5. Turn the terminal screws counter-clockwise to loosen
6. Insert the wires into the corresponding terminals
Make sure that the polarity is correct!
7. Turn the screws clockwise to tighten
OK
8. Close the cover
9. Prepare the other end of each wire for connection to the DC power supply
3.8.2 Connecting to the DC Power Supply
Connect the GN panel to a DC power supply using the DC power plug and a corresponding
cable (see page 34).
The DC power supply must be able to output 50W to cope with the inrush current.
NOTE
ꢀ
•
The DC power supply should be able to be switched off and on via an
isolating switch.
34
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.8 Connecting the System to the Power Supply
•
The unit is only completely disconnected from the DC main power supply
when the DC power cord is disconnected either from the power supply or
the unit. Therefore, the DC power cord and its connectors must always
remain easily accessible.
1 2
+
–
Connecting to the DC power supply
1
2
PC unit
Display
WARNING
Ensure that the DC power supply is switched off via an isolating
switch in order to ensure that no power is flowing from the
external power supply during the connection procedure.
Otherwise, electric shock may be the result.
!
1.
2.
3.
Procedure
1. Connect the 3-pin DC power connector of the DC power cable to the
appropriate DC power connector of the GN panel.
The DC power connector of the system is located on the rear bottom side and is
place.
2. Connect the other end of the DC power cable to the terminals of the 24V DC
power supply
Ensure that the power connections maintain the proper polarity.
3. Switch on the isolating switch in order to apply voltage to the terminals of
the power supply (cable wires)
When turning on power to the system via the isolating switch, the GN panel will
immediately boot the installed operating system.
35
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
3.9 Mounting the System to a Subframe or Panel
The system is delivered with mounting clamps and Allen screws in order to mount the system
to a subframe or panel.
1
2
3
3
3
3
4
Mounting a GN10
1
2
3
4
Example of subframe for system installation
Enclosure of the 10.4" display
Mounting clamp with screw
Compact flash card slot
1
2
3
3
3
4
Mounting a GN15
1
2
3
4
Example of subframe for system installation
Enclosure of the 15" display
Mounting clamp with screw
Compact flash card slot
36
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.9 Mounting the System to a Subframe or Panel
The mounting clamps enable easy, fast mounting of the GN unit onto an instrument panel or
wall panel.
Item
GN07
GN10
GN12
GN15
Rear side enclosure
(W x H x D, mm)
215 x 146.3 x 45.75 295 x 234 x 44
324 x 263 x 49.5
406.4 x 311 x 50
Panel cutout
(W x H, mm)
217 x 148
1.5 – 6
4 x
297 x 236
1.5 – 6
8 x
326 x 265
1.5 – 8
6 x
408 x 313
1.5 – 8
8 x
Metal mounting panel
thickness (mm)
Mounting clamps with
screws
Required tool
Allen wrench 2mm
Proper torque
Mounting position
Tighten the screws with a torque of 0.5•Nm
Ensure the vertical and horizontal alignment of the system.
NOTE
ꢀ
•
•
In order to ensure IP65 front sealing against dust and water, mount the
system on a non-textured surface. Before you install the GN unit on a panel
or a subframe for a switching cabinet, verify that the seal on the rear of the
front plate is in perfect condition. The seal has to be in place without
defects and dirt.
When you install the GN07 on a panel or a subframe for a switching cabinet,
leave enough free space at the rear top side to insert or remove the CF card.
To mount the system to a subframe or to a panel, proceed as follows:
1.
2.
Procedure
3.
1. Assemble the mounting clamps with the Allen screws included
2. Depending on the dimension of the display enclosure of your system, cut a
hole in the panel/subframe
Refer to the tables for the panel cut-out dimensions. The panel where you intend
to attach the system must be accessible from both the front and the rear side. The
system must be turned off and disconnected from the power supply and
peripheral devices
3. Insert the system into the panel cut-out from the front
In order to ensure the protection class IP65 on the front after installation, the
contact surface with the seal must be clean and flush.
4. Ensure the vertical and horizontal alignment of the system
37
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
5. Fasten the system from the rear using the mounting clamps
6. Hook the mounting clamps with screws from the rear side of the panel into
the corresponding pairs of slots of the enclosure
6.5mm
Maximum height for mounting the bracket
The system must be attached firmly with the screws. Tighten the screws with a
torque of 0.5•Nm.
38
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.10 Accessing Internal Components
3.10 Accessing Internal Components
WARNING
Before removing the cover of the GN unit in order to gain access
!
to the internal components, the system must be powered down
and the power cord has to be disconnected from the power
supply.
Otherwise, electric shock may be the result.
The system may only be opened in accordance with the description in this hardware manual
for:
•
•
Replacing the lithium battery
Configuring the RS422/RS485 interface (GN10/GN12/GN15). These procedures may
be carried out by qualified specialized personnel only.
CAUTION
•
•
Do not operate the system without the cover.
Please observe the safety instructions for handling assemblies with
static-sensitive devices. Failure to do so can result in damage to the device.
3.10.1 Configuration of the RS422/RS485 Port
switches. In order to change the factory configuration (RS422 4-channel mode), proceed as
follows:
NOTE
ꢀ
The new port configuration has to be set before the system is installed on a
panel or into a switching cabinet. The system must be disconnected from the
power supply. Disconnect all peripheral devices. Before you begin, ensure that
you have a clean, flat and ESD-safe surface to work on.
1.
2.
Procedure
3.
1. Close all applications and shut down the system properly
2. Disconnect the power cord from the power supply
3. Disconnect all peripheral devicess
The system should lay on a flat, clean surface with the front panel facing
downwards. Make sure that the display surface is protected against scratching
39
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
and damage.
4. GN07: Unscrew the screws that secure the cover
GN10/12/15: Unscrew the screws that secure the metal cover on the
optional interface area
5. Remove the cover and put it aside
6. Locate the DIP switches in the unit
7. By use of an insulated thin tool (e. g. screwdriver or a stylus) set the DIP
switches to the up (for ON) or down (for OFF) position corresponding to the
port configuration required
timeout.
ON
1
2
3
4
5
6
7
8
8. Put the cover back on
9. When the cover is firmly in place, fasten the screws
40
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
3.10 Accessing Internal Components
3.10.2 Replacing the Lithium Battery
The motherboard is equipped with a lithium battery.
Location of the lithium battery
1
2
Lithium battery
Motherboard
WARNING
There is a risk of explosion if the battery is replaced by an
incorrect type. The lithium battery must be replaced with an
identical battery or of the same battery type (lithium battery 3,0V
for a real-time clock, type: CR2032). The lithium battery type must
be UL-listed.
!
To replace this battery, please proceed as follows:
1.
2.
Procedure
3.
1. Close all applications and shut down the system properly
2. Disconnect the power cord from the power supply
3. Disconnect all peripheral devicess
The system should lay on a flat, clean surface with the front panel facing
downwards. Make sure that the display surface is protected against scratching
and damage.
4. GN07: Unscrew the screws that secure the cover
GN10/12/15: Unscrew the screws that secure the metal cover on the
optional interface area
5. Remove the cover and put it aside
41
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Description
GN Series Hardware Manual
6. Pull the battery outwards
7. Position the new lithium battery in the battery holder with the positive (+)
pole facing up
8. Gently push the battery as far as it goes into the holder
Make sure that you insert the battery correctly. The positive pole must be facing
up!
9. Put the cover back on
10. When the cover is firmly in place, fasten the screws
NOTE
ꢀ
Do not dispose of lithium batteries in domestic waste. Dispose of the battery
according to the local regulations dealing with the disposal of hazardous
materials (e.g. take it to the collection points for old batteries).
42
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4
Technical Data
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
GN Series Hardware Manual
4.1 General Specifications
GN series
GN07
GN10
GN12
GN15
TFT LCD
Display
Screen size
Active area (H x V)
[mm]
7"
10.4"
211.2 x 158.4
12.1"
15"
152.4 x 91.44
304.1 x 228.1
246.0 x 184.5
Resolution
(H x V) [pixel]
800 x 480
800 x 600
(SVGA)
800 x 600
(SVGA)
1024 x 768
(XGA)
Pixel pitch
0.1905 x 0.1905
0.264 x 0.264
0.3075 x 0.3075
0.297 x 0.297
(H x V) [mm]
262k
1 x CCFL
230
Color depth
16.2M
2 x CCFL
Backlight
Brightness cd/m2
33-LED
330
400
1x 6bit LVDS
350
Control signal
Viewing angle (°)
(r / l / u / d)
60 / 60 / 40 / 55
400:1
70 / 70 / 55 / 65
70 / 70 / 50 / 60
70 /70 / 65 /60
700: 1
Contrast ratio
500:1
500:1
4 wire resistive analog
Touch screen
Yes
Single-board computer with Intel®
Atom™ processor N270 1.6 GHz
Yes
Lithium battery 3.0 V for real-time
clock. Type CR2032, UL-listed
Yes
Yes
Reset button (RESET)
Power button (PWR)
12V DC (2.8A max.) to 24V DC (1.8A max.) ±10%
Yes
Power supply input (see note)
Status LEDs, system and storage
medium
2 x
3 x
USB 2.0 interface
2 x
Ethernet interface
(10/100/1000Mbps) (LAN0, LAN1)
1 x
1 x
VGA interface
Serial RS232 interface (COM1)
Protection class IP65 (front side)
Optional interfaces:
Yes
1 x
2 x
•
•
•
•
Serial RS422/485
Serial RS232
Industrial fieldbus
Industrial Ethernet (not GN07)
Yes
1 x
Mini PCIexpress slot
Compact flash card slot
Storage media
CF card
Phoenix/Phoenix-Award
BIOS
Standard: Windows CE
Operating system
(Other operating systems available upon request.)
1 x
DC power connector (3 pin)
44
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
4.1 General Specifications
GN series
GN07
GN10
GN12
GN15
1 x
6 x (2 screws)
DC power plug (3 pin)
Mounting clamps
4 x (1 screw)
8 x (1 screw)
8 x (2 screws)
NOTE
ꢀ
The DC power supply must be able to output 50W to cope with the inrush
current.
45
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
GN Series Hardware Manual
4.2 Environmental Specifications
Item
Specification
Thermal management
Operating temperature / relative humidity
Passive cooling for CPU and system
0 … +45°C, 20 – 90% (non-condensing)
-20 … +70°C, 10 – 90% (non-condensing)
Storage / transit temperature / relative
humidity
Operating altitude
-300m to 3,000m
Storage / transit altitude
Operating shock
-300m to 4,500m
15G, 11ms duration, half-sinus
50G, 11ms duration, half-sinus
10 – 58Hz ± 0.1 mm
58 – 500Hz; 1G
Storage / transit vibration
Operating vibration
Storage / transit vibration
Degree of protection
10 – 58Hz ± 0.15 mm
58 – 500Hz; 2.0G
IP65 (front panel side)
46
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
4.3 Dimensions
4.3 Dimensions
Dimension
Height
GN07
GN10
GN12
GN15
168mm
235mm
50.3mm
277mm
348mm
49.6mm
312mm
380mm
57.1mm
354mm
449.4mm
55.6mm
Width
Depth (total)
Depth (without front plate)
Weight
47.3mm
2.6kg
45.6mm
3.6kg
51.1mm
4.9kg
51.6mm
6.5kg
4.3.1 Front Views
GN07
239
157
235
47
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
GN Series Hardware Manual
GN10
214.2
348
GN12
248
380
48
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
4.3 Dimensions
GN15
306
449.4
4.3.2 Rear and Right Side Views
GN07
45.7
3
1.6
10
215
49
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
GN Series Hardware Manual
GN10
44
4
17.2
15
1.6
295
GN12
49.5
22.8
6
1.6
324
50
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
4.3 Dimensions
GN15
50
23.2
4
77.2
295
1.6
406.4
51
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
GN Series Hardware Manual
4.4 Pin Assignments
In this section you can find the pin assignments for the standard interfaces.
4.4.1 Ethernet Interfaces (LAN0 and LAN1)
Pin No.
Signal name
MDI0+
RJ45 (female) connector
1
2
MDI0-
3
MDI1+
4
MDI2+
5
MDI2-
6
MDI1-
7
MDI3+
8
MDI3-
LED (green)
LINK / ACTIVE
LED (off/green/yellow) 10/100/1000 Base-T
4.4.2 USB Interfaces
Pin No.
Signal name
4-pin USB socket, type A, version 2.0/1.1
1
2
3
4
VCC
Data -
Data +
Ground
4.4.3 RS232 (COM1, COM2)
Pin
1
Signal short name
Long name
9-pin Sub-D plug (male)
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
Data carrier detect
Receive data
2
3
Transmit data
Data terminal ready
Signal ground
Data set ready
Request to send
Clear to send
1
5
4
5
6
6
9
7
8
9
Ring indicator
52
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
4.4 Pin Assignments
4.4.4 RS422/RS485 Configured as RS422 (4-Channel Mode)
Use the DIP switches to configure the interfaces (see page 23).
Pin
1
Signal short name
TxD -
Long name
9-pin Sub-D plug (female)
Transmit data -
Receive data +
Transmit data +
Receive data -
Signal ground
2
RxD +
3
TxD +
1
5
4
RxD -
5
GND
6
RTS -
Request to send -
Request to send +
Clear to send +
Clear to send -
9
6
7
RTS +
8
CTS +
9
CTS -
4.4.5 RS422/RS485 Configured as RS485 (4-Wire Mode), Full Duplex, Bus
Master
Use the DIP switches to configure the interfaces (see page 23).
Pin
1
Signal short name
Long name
Transmit data -
Receive data +
Transmit data +
Receive data -
Signal ground
Not connected
Not connected
Not connected
Not connected
9-pin Sub-D plug (female)
TxD -
RxD +
TxD +
RxD -
GND
NC
2
3
1
5
4
5
6
9
6
7
NC
8
NC
9
NC
4.4.6 RS422/RS485 Configured as RS485 (2-Wire Mode), Half Duplex
Use the DIP switches to configure the interfaces (see page 23).
Pin
1
Signal name
9-pin Sub-D plug (female)
Data -)
NC
2
3
Data +)
NC
1
5
4
5
GND
NC
6
9
6
7
NC
8
NC
9
NC
53
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
GN Series Hardware Manual
4.4.7 VGA Port (VGA)
Pin
1
Signal name
Analog red output
Analog green output
Analog blue output
Not connected
GND
15-pin Sub-D-Plug (female)
2
3
4
5
6
GND
1
5
7
GND
8
GND
9
+5V (DDC)
GND
10
6
15
11
10
11
12
13
14
15
Not connected
SDA (DDC)
TTL Hsync
TTL Vsync
SCL (DDC)
4.4.8 DC Power Connector
Pin
1
Signal name
3-pin POWER SUBCON (male)
0V input (-24V DC polarity on the unit panel)
+24V DC (input) NC
2
3
Functional earth
54
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
GN Series Hardware Manual
4.5 Cables
4.5 Cables
Type of communication
Description
Product no.
RS232C
AFC8513D
AIP81862E1D
AIGNCAB232D
—
•
•
•
•
•
•
GN COM1 to PLC TOOL port (5-pin mini-DIN)
Cable length: 3m
RS232C
RS232C
Ethernet
GN COM1 to FP2 COM/MCU RS232
Cable length: 2m
GN COM1 (9-pin Sub-D), loose wire
Cable length: 3m
You may use a commercially available Ethernet LAN
cable to program the GN panel, for example.
RS232 connection cable wiring
GN side
5
1
9-pin Sub-D female
metal housing
9
6
*
Signal
Wire color
Pin no.
Signal
**
Housing
FG
Green
White
Brown
SG
SD
RD
SG (GND)
5
2
3
1
4
6
7
8
RD (RXD)
SD (TXD)
CD (DCD)
ER (DTR)
DR (DSR)
RS (RTS)
Example wire colors, e.g. for cable
product nr. AFC8513D
*
Connect cable shield low-resistive
to EMC ground.
**
CS (CTS)
55
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
GN Series Hardware Manual
RS485 connection cable wiring
GN side
1
5
9-pin Sub-D male
metal housing
6
9
Signal
Pin no.
Signal
FG
*
Housing
1
3
5
Data-)
Data-)
Data+)
GND/SG
Data+)
GND/SG
Connect cable shield low-resistive to EMC ground.
*
56
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
DIP switches...........................................23
Display..............................................17, 44
Display with Touch Screen.....................17
Index
A
E
Accessing Internal Components.............39
All Views .................................................14
Applicable Directives and Standards........8
Electromagnetic compatibility...................7
Electromagnetic Compatibility ..................7
Electrostatic discharge .............................5
Electrostatic Discharge (ESD)..................5
Environmental Specifications .................46
Ethernet ............................................25, 52
Ethernet Interfaces (LAN0 and LAN1)....52
B
Battery ....................................................41
BEFORE BEGINNING...............................i
Bottom View............................................23
C
F
Cables.....................................................55
Calibrating the Touch Screen.................17
Calibration...................................17, 18, 21
Calibration under Windows® XP ............18
FCC statement..........................................6
FCC Statement.........................................6
Front Plates ............................................17
Front View...............................................16
Front Views.............................................47
Calibration under Windows® XP
Embedded...........................................21
CE directives.............................................8
Cleaning..................................................22
Compact flash card.................................44
Compact flash card slot....................27, 30
Compact Flash Card Slot .......................27
Configuration of the RS422/RS485 Port.39
G
General Specifications............................44
Grounding...........................................5, 26
Grounding Methods ..................................5
Grounding Screw (M4) with Lock Washers
............................................................26
Connecting the System to the Power
H
Supply .................................................33
Connecting to the DC Power Supply......34
Hampshire TSHARK software....17, 18, 21
D
I
DC power connector...................25, 33, 54
DC Power Connector........................25, 54
DC power plug............................10, 25, 33
DC Power Plug .......................................33
Dimensions.......................................47, 49
Important Symbols.................................... ii
Interface configuration............................23
Interfaces..........................................23, 25
Introduction...............................................1
57
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
GN Series Hardware Manual
L
RS232 (COM1, COM2)...........................52
RS422/RS485 Configured as RS422
LAN0 and LAN1 Ethernet Interface
(4-Channel Mode) ...............................53
Connectors..........................................25
RS422/RS485 Configured as RS485
Left and Right Side View ........................28
(2-Wire Mode), Half Duplex.................53
RS422/RS485 Configured as RS485
(4-Wire Mode), Full Duplex, Bus Master
............................................................53
M
Material of front plate..............................17
Monitor..............................................25, 54
Mounting clamp.....................10, 27, 30, 36
RS422/RS485 Serial Interface................23
Rubber coat ............................................16
Mounting the System to a Subframe or
Panel ...................................................36
S
Safety Instructions ....................................2
Scope of Delivery......................................9
Serial interface............................23, 52, 53
Single-Board Computer ..........................32
Specifications....................................44, 46
Status LEDs............................................26
Stylus ................................................10, 17
O
Opening the system................................39
Optional Interfaces..................................23
Overview...................................................4
P
Panel cutout............................................36
Pin Assignments .....................................52
Power button...........................................23
Power LEDs............................................26
Product Description.................................13
Product Parts ..........................................10
Protection class...........................36, 44, 46
T
Technical Data........................................43
Timeout...................................................23
Top View.................................................27
Touch Screen Care and Cleaning ..........22
Type label ...................................11, 28, 30
Type Label and Product Identification ....11
R
U
Real-time clock .......................................41
Rear and Right Side Views.....................49
Rear View ...............................................30
Record of Changes.................................60
Replace battery.......................................41
Replacing the Lithium Battery.................41
Reset button............................................26
Reset Button ...........................................26
USB interface....................................16, 52
USB Interface on the Front.....................16
USB Interfaces........................................52
V
Ventilation holes..................................4, 27
VGA interface....................................25, 54
58
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
GN Series Hardware Manual
VGA Interface Connector .......................25
VGA Port (VGA)......................................54
59
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
Record of Changes
Manual No.
Date
Description of Changes
ACGM0192V1EN
April 2010
First edition.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Miele Door MLT 75 User Manual
Miele Washer t 250 c User Manual
Moxa Technologies Switch EDS 508 User Manual
NeumannBerlin Microphone PS 10 User Manual
Omega Engineering Thermometer HHM57 User Manual
Optimus Cassette Player 120 2113 User Manual
Panasonic Answering Machine KX TG8162AL User Manual
Panasonic Car Stereo System CQ 5335U User Manual
Panasonic Personal Computer CF 51 User Manual
Patton electronic Network Card Model 3088 I User Manual