In Remote Fault Detection (RFD), the UTP port
transmits a Link signal only when receiving a Link at the
fiber port. The fiber port transmits a Link only when
receiving Link signals both at the fiber port and the UTP
port. As a result, fiber faults (no “Link” received at the
fiber) are looped-back and can be reported to the network’s
core [Fig 1(c)].
2. Attach the UTP port to a 10BASE-T Ethernet device
using a Category 5 cable. If the attached device
features 10/100 or 10/100/1000 Auto-Negotiation,
disable this feature and manually set the UTP port
speed of the connected device to 10Mbps.
ABOUT THIS MANUAL:
FRONT PANEL DIP-SWITCH SETTINGS:
This document supports revision “xx/20” of the
iConverter 10FL/T. Please refer to the serial number
label on the ROM chip of the 10FL/T for the revision
number of your product. This revision incorporates the
following improvements to the 10FL/T.
iConverter 10FL/T User Manual
Fig. 2 DIP-Switches
3. Using a multimode or single-mode dual-fiber cable as
required per the converter type, attach the fiber port
to a 10BASE-FL mating Ethernet device. The transmit
(Tx) must attach to the receive side of the mating
device and the receive (Rx) must attach to the
transmit side.
REMOTE FAULT DETECT “R/FLT DET” DIP-SWITCH:
1. Link Propagate is the default link mode.
When the Remote Fault Detect DIP-Switch is in the
“R/Flt Det” position, the Remote Fault Detect mode is
enabled. When in the “Norm” (factory setting) position,
Remote Fault Detect is disabled and Link Propagate is
enabled.
LP
LP
OVERVIEW:
Fiber
The iConverter 10FL/T converters support the IEEE 802.3
Ethernet standard and convert 10BASE-T unshielded
twisted pair (UTP) to 10BASE-FL fiber optic cabling. Mod-
els are available for multimode (MM) and single-mode
(SM) dual fiber and single-mode single-fiber.
UTP
UTP
Fiber
4. Single-fiber (SF) converters must be used in matched
pairs. The transmit (Tx) and receive (Rx) wavelengths
of one converter must match the receive (Rx) and
transmit (Tx) wavelengths of the mating converter.
For example, an 8310-1 must be connected to an
8311-1.
iConverter 10FL/T Dual Fiber Modules
Note that connecting two converters when both are
set to RFD mode is illegal and will cause a “deadly
embrace” lockup.
Switch 1 Converter A
LP
Converter B Switch 2
LP
Connector Type
Fiber Type
Distance
The 10FL/T supports Half-Duplex and Full-Duplex modes
and features a crossover UTP switch for easy
attachment to hubs, switches and workstations.
ST
8300-0 8302-0
8300-1
SC
MT-RJ
LC
RJ45 Crossover “X / =” Switch (Not Shown):
MM
MM
SM
SM
SM
2 km
5 km
-
-
-
When connecting the UTP port to a hub or switch, set
switch to Straight-Through “=” (factory setting). When
connecting to a workstation, set it to Crossover “X”.
-
8304-1
The 10FL/T can be used in an unmanaged or managed
fashion. When unmanaged, the 10FL/T can be installed
in a chassis without a Network Management Module (NMM).
To be managed, a NMM module must be installed in the
same chassis.
30 km
60 km
120 km
8301-1 8303-1 8305-1 8307-1
Switch 1 Converter A
LP
Converter B Switch 2
RFD
8301-2 8303-2
8303-3
-
-
8307-2
8307-3
LED INDICATORS:
-
LED
Color Description
Pwr:
Yellow On-Power on
iConverter 10FL/T Single-Fiber Modules
Lk/Act (F/O): Green On-Link; Blink-Activity
Lk/Act (UTP): Green On-Link; Blink-Activity
LINK MODES:
In order to accommodate different user needs, the 10FL/T
supports two different linking modes.
Fiber /
Connector
Type
Tx: 1310 nm,
Rx: 1550 nm
Tx: 1550 nm,
Rx: 1310 nm
Distance
MOUNTINGAND CABLE ATTACHMENT:
The iConverter modules are hot-swappable and can be
installed into any iConverter chassis.
Switch 1 Converter A
LED On
Converter B Switch 2
SM / SC
SM / SC
20 km
40 km
8310-1
8310-2
8311-1
8311-2
In Link Propagate (LP), sometimes referred to as “Link
Loss Carry Forward”, a converter port transmits a Link
signal only when receiving a Link at its other port. For
example, the UTP transmits a Link only when receiving a
Link at the fiber port [Fig 1(b)]. Link propagate is the
factory default setting.
LED Off
1. Using the chassis’ module guides for alignment,
insert the module into the selected slot and secure using
the front panel fastener screw.
LED status depends on connected device
Off if device is AN, On if device is Manual
For wide temperature (-40 to 60º C) modules, add a "W" to the
end of the model number. Consult factory for other configurations
and extended temperature(-40 to +75º C) modules.
When using single-fiber (SF) media converter models, the Tx
wavelength on one end has to match the Rx wavelength on the other.
Fig. 1 Link Modes
Page 2
Page 3
Page 4
Page 5
TECHNICAL SUPPORT:
10FL/T SPECIFICATIONS:
Notes:
Limitation of Warranty
Warning
For help with this product, contact our Technical Support:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other
than that contained in the operating instructions, unless
you are qualified and certified to do so by Omnitron
Systems Technology, Inc.
The foregoing warranty shall not apply to defects
resulting from improper or inadequate use and/or
maintenance of the equipment by Buyer, Buyer-supplied
equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including
repairs of equipment by personnel not specifically
authorized and certified by Omnitron), or misuse, or
operating outside the environmental specification of
the product (including but not limited to voltage, ambient
temperature, radiation, unusual dust, etc.), or improper
site preparation or maintenance.
Model Type
Protocols
10FL/T
Phone:
Fax:
(949) 250-6510
(949) 250-6514
10BASE-FL, 10 BASE-T
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Address: Omnitron Systems Technology, Inc.
140 Technology Dr., #500
UTP
Connectors
RJ-45
Irvine, CA 92618 USA
Fiber
Connectors
SC, ST, LC, MT-RJ,
Single-Fiber SC
E-mail:
URL:
Warranty
This product is warranted to the original purchaser
against defects in material and workmanship for a
period of 2 YEARS from the date of shipment. A
LIFETIME limited warranty may be obtained by the
original purchaser by REGISTERING this product with
Omnitron within 90 days from the date of shipment. To
register, complete and mail or fax the enclosed
Registration Card to the indicated address. You may
also register your product on the internet at
warranty period, Omnitron will, at its option, repair or
replace a product which is proven to be defective.
Controls
LS/LP, RFD
Power, F/O Link, UTP Link
W:0.85" x D:4.5" x H:2.8"
8 oz.
LED Displays
Dimensions
Weight
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
UL, CE, FCC Class A
NEBS Level 3
,
Compliance
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for
any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Power
Requirement
0.5A @ 3.3VDC (typical)
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense.
Omnitron will pay the shipping charge to return the
product to Buyer’s designated US address (within the
48 contiguous states and the District of Columbia)
using Omnitron’s standard shipping method.
Temperature
Humidity
Altitude
5 to 95% (non-condensing)
-100m to 4000m
830,000
MTBF (hrs)
040-08300-001J 9/07
Page 6
Page 7
Page 8
Page 9
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
|