Nortel Networks Answering Machine P0886634 User Manual

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •  
Norstar Voice Mail 4.0 FAX  
Installation Guide  
• • • • • • • • • • • • • • • • • • • • • • • • •  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ii  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory information iii  
Regulatory information  
FCC Regulations  
This equipment complies with Part 68 Rules and Regulations of the FCC  
Regulations for direct connection to the public switched telephone network.  
DOC Regulations  
This equipment complies with CS-03 Rules and Regulations of the Canadian DOC  
Regulations for direct connection to the public switched telephone network.  
Radio frequency interference  
Warning: This equipment generates, uses, and can radiate radio frequency energy,  
and if not installed and used in accordance with the instruction manual, may cause  
interference to radio communications. It has been tested and found to comply with  
the limits for a Class A computing device pursuant to Subpart J of Part 15 of the  
FCC Rules and CSA specification C108.8, which are designed to provide  
reasonable protection against such interference when operated in a commercial  
environment. Operation of this equipment in a residential area is likely to cause  
interference in which case users will be required at their own expense to take  
whatever measures necessary to correct the interference.  
This apparatus does not exceed the Class A limits for radio noise emissions from  
digital apparatus set out in the Radio Interference Regulations for the Canadian  
Department of Communications.  
CAUTION  
The Norstar Applications Module contains fragile electronic parts. DO NOT  
DROP OR BUMP THE MODULE.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
iv Repair facilities  
Repair facilities  
In the event of equipment malfunction, all repairs must be performed by Northern  
Telecom or by one of its authorized dealers.  
In the USA:  
In Canada:  
Northern Telecom Inc.  
Northern Telecom Canada Ltd.  
30 Norelco Drive  
Weston, ON  
Nashville Repair and Distribution Center  
640 Massman Drive  
Nashville, TN 37210  
M9L 2X6  
Attn: RA#  
Tel: (416) 744-5201  
Fax: (416) 744-5227  
Tel: (615) 883-9220  
Note: You receive an RA# when you call the repair center in Nashville. This  
number should appear on the package of any and all parts sent to this  
location for repair.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Introduction to Norstar Voice Mail FAX  
1
Norstar Voice Mail FAX provides Norstar Voice Mail with fax functionality. This  
installation guide is intended for the installer of Norstar Voice Mail FAX and  
describes how the FAX option should be installed and prepared for operation.  
Norstar Voice Mail FAX can be installed on systems equipped with either a Media  
Services Base Interface Card (BIC) or Digital Voice Cards (DVC)s. The procedures  
for installing the Digital Fax Card (DFC) differs between the systems. Follow the  
instruction on which system you have installed.  
The installer is responsible for:  
installing the DFC  
connecting the DFC to the DVCs or BIC  
enabling the FAX software  
FAX overview  
The Norstar Voice Mail FAX software is factory installed on the Norstar  
Applications Module (NAM). The FAX software must be enabled after the DFC is  
installed.  
The FAX option provides Norstar Voice Mail with the following features:  
Fax Mail – Faxes received from external fax machines are stored in personal  
mailboxes  
Fax Answering – Faxes received from external fax machines are automatically  
sent to a predefined fax extension  
Fax-on-demand – An external caller can request a fax to be sent to them from a  
Fax-on-demand Mailbox  
Fax Overflow – When the office fax machine is unavailable for use, faxes can  
be temporarily stored in a fax Overflow Mailbox and printed later  
Fax System Group Message (Fax Broadcast) – A Fax System Group Message  
can be sent whenever you want to notify a special group, by way of a fax, of a  
pending event or company notice  
To print fax documents from a Fax Overflow Mailbox, the fax machine must be  
connected to the same Norstar system as the NAM. To print a fax document from a  
Personal Mailbox, the fax machine does not need to be connected to a Norstar  
system. A fax machine may also be required for loading fax documents in a Fax-  
on-demand Mailbox.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2 Introduction to Norstar Voice Mail FAX  
Figure 1 FAX overview  
External fax machine  
External caller receives a fax from  
Fax-on-Demand Mailbox.  
OR  
Fax sent to office fax machine behind  
Norstar or to a Personal Mailbox.  
Personal Mailbox  
receives a fax as part of  
a message.  
Other office  
Norstar  
office  
Mailboxes are accessed and  
fax programming is done from  
here.  
Fax Overflow  
Mailbox stores faxes if  
office fax machine is busy  
and prints them later.  
DVC or BIC  
DFC  
Norstar  
Telephone  
Norstar  
Voice Mail  
ATA  
Fax-on-demand Mailbox  
sends out a fax at the  
request of an external caller.  
Fax-on-demand faxes can be fed  
into office fax machine and are  
then sent to the desired  
Fax-on-demand Mailbox.  
Office fax machine  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction to Norstar Voice Mail FAX 3  
DFC overview  
The Digital Fax Card (DFC) is installed in an expansion bus slot on the Norstar  
Application Module (NAM) and supports four Fax Channels.  
There are no Time Compression Multiplexing (TCM) connections to the DFC. The  
DFC uses the Voice Channels on the Digital Voice Cards (DVCs) or BIC to connect  
the Fax Channels to fax machines or a call.  
Note: When Norstar Voice Mail FAX is using a Voice Channel to connect to the  
fax machine or a caller, that Voice Channel cannot be used by other users  
until the FAX function is complete.  
Specifications  
The DFC is an AT bus compatible card that provides:  
9600 baud with auto-step-down to 7200, 4800 and 2400 bps  
DTMF generate and detect  
error correction mode  
fine and normal image resolution  
V.21, V.27, V.29, T.4 (MH&MR), T.6 (MMR), T.30 protocols  
four Group III analog Fax Channels  
Special tools  
Before you begin replacing or upgrading the components, ensure you have the  
following equipment:  
#2 Phillips head screwdriver with a 3.5 in. long blade  
3/16 in. slot screwdriver  
an antistatic grounding strap  
3/16 in. nut driver (recommended)  
You may also need the Norstar Applications Module Installation and Maintenance  
Manual. The Norstar Applications Module Installation and Maintenance Manual  
is included on the Norstar Voice Mail 4.0 Documentation and Client Software CD-  
ROM. All the Norstar Voice Mail Installation Manuals on the CD-ROM are  
protected by the password: Norstar99.  
CAUTION  
You must wear an antistatic grounding strap at all times when handling  
electronic components. Failure to do so may result in damage to the equipment.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
4 Introduction to Norstar Voice Mail FAX  
Precautions  
Before installing or upgrading a DFC, you must take the following precautions:  
Shut down the Norstar Voice Mail system—A shutdown procedure allows  
Norstar Voice Mail to perform all necessary shutdown activities before power  
is removed. For more information, refer to "Shutting down the Norstar Voice  
Unplug the NAM power cord—The NAM power supply contains high  
voltage. If you do not unplug the power cord, you may severely injure yourself.  
Also, if cards are installed or removed from the NAM before the power cord is  
unplugged, the cards and/or the NAM may be damaged.  
Wear an antistatic ground strap—Static electricity can damage the  
components on the cards and the NAM. Always wear a properly grounded  
antistatic strap while handling the DFC, DVC, BIC or any other Norstar Voice  
Mail component. Ground yourself by attaching one end of the grounding strap  
to your wrist and the other end to a grounded metal surface.  
Enabling the FAX software  
The FAX option must be enabled after installing the DFC. Refer to "Enabling the  
instructions on how to enable the FAX option.  
After FAX capability is added to Norstar Voice Mail, you can add or customize Fax  
Overflow and Fax-on-demand information. For more information about  
customizing the FAX software, refer to the Norstar Voice Mail FAX Set Up and  
Operation Guide.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the DFC on systems equipped with  
DVCs  
2
Only one DFC can be installed in the Norstar Applications Module (NAM). The  
DFC connects to the DVCs through the PCM Expansion Bus (PEB) cable. This  
cable must be connected from the DFC to each DVC. The PEB cable connects the  
DFC to the DVC to share the ports connected to Norstar.  
The following section provides step-by-step instructions for the installation of the  
FAX software, a DFC and the PEB cable in a Norstar Voice Mail system equipped  
with Digital Voice Cards (DVC)s. For information on installing a DFC in a  
Norstar Voice Mail system equipped with a Media Services Base Interface Card  
Figure 2 Digital Fax Card and PEB cable  
PEB Connector  
Interrupt  
SW2  
SW1  
PEB Terminator  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6 Installing the DFC on systems equipped with DVCs  
Installation overview  
To add Norstar Voice Mail FAX to a system equipped with DVCs you must:  
Set the DFC jumpers  
Install the DFC  
Connect the DFC to the DVCs with the PEB cable  
Enable the FAX software  
Shutting down the Norstar Voice Mail system  
Before you remove the power from Norstar Voice Mail, you must shutdown the  
Norstar Voice Mail system. Performing a shutdown allows Norstar Voice Mail to  
perform all necessary shutdown activities before the power is removed. A shutdown  
prevents data from being lost.  
Note: A shutdown must be done from a Norstar telephone with a two-line display.  
To shutdown the Norstar Voice Mail system:  
Feature  
9
1
5
1. Press  
.
Password  
2
2
2
3
7
7
2
2. Enter the default password  
(ACCESS2) and press OK.  
ACCESS Server  
3. Press NEXT.  
BACK  
ADMIN  
System shutdown  
BACK NEXT  
4. Press SHOW.  
Shutdown type  
5. Press NEXT until the display shows:  
QUIT  
GRACE  
Shutdown type  
QUIT NEXT  
6. Press QUICK, then YES to continue with the  
shutdown.  
The Norstar Voice Mail system shuts down in 15 seconds. For more information  
about shutdown procedures, refer to the Norstar Applications Module Installation  
and Maintenance Manual.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installing the DFC on systems equipped with DVCs 7  
Opening the NAM  
1. Warn customers that Norstar Voice Mail will be out of service while you are  
installing the FAX option.  
2. Shutdown the Norstar Voice Mail system.  
3. Unplug the NAM power cord from the AC outlet.  
4. Ground yourself by attaching one end of the grounding strap to your wrist and  
the other end to a grounded metal surface.  
5. Open the module door. The door may be locked. To unlock the door, use a  
screwdriver to turn the lock in the bottom-right corner of the door. Turn the  
lock 90° counterclockwise until the screwdriver slot is vertical.  
Figure 3 Unlocking the module door  
6. Remove the two screws holding the front cover to the module. The screws are  
located along the top of the front cover.  
7. Slide the front cover up and out from the module.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
8 Installing the DFC on systems equipped with DVCs  
Figure 4 Removing the front cover  
Installing the DFC in the NAM  
1. Make sure you are wearing your antistatic grounding strap. Ground yourself  
by attaching one end of the grounding strap to your wrist and the other end to  
a grounded metal surface.  
2. If you are installing FAX on an earlier NAM, locate slot 7 on the expansion  
bus. Remove the slot cover screw and the metal slot cover from the slot. Refer  
If you are installing FAX on a NAM II, locate slot 8 on the expansion bus.  
Remove the slot cover screw and the metal slot cover from the slot. Refer to  
Keep the metal slot cover and screw. You must re-install the metal slot cover  
if you remove the DFC.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the DFC on systems equipped with DVCs 9  
Figure 5 Locating the expansion bus slots on a NAM  
DFC - Slot 7  
Figure 6 Locating the expansion bus slots on a NAM II  
DFC - Slot 8  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
10 Installing the DFC on systems equipped with DVCs  
3. Switch SW1 should be set according to the following table:  
Position 8  
State off  
7
6
5
4
3
2
1
on  
off  
off  
on  
on  
on  
on  
4. Switch SW2 should be set according to the following table:  
Position 2  
State on  
1
on  
5. Ensure there is a jumper on position 10 of the INTERRUPT.  
Note: The settings in these table are the default values and should be set  
the location of the switch SW1, SW2 and the INTERRUPT jumpers.  
6. Carefully hold the DFC along the top only. Insert the card by aligning  
between the metal groove on one side and the slot opening on the other side.  
7. Push the DFC straight in until it is snugly in place. Ensure the edge connector  
is firmly inserted into the socket.  
8. Fasten the slot cover screw in the DFC slot cover.  
Note: If there is a DVC in slot 6 of the NAM, you must connect the PEB  
cable to the DFC before installation. If there is a DVC in slot 7 of the  
NAM II, you must connect the PEB cable to the DFC before  
installation.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the DFC on systems equipped with DVCs 11  
Installing the PEB Cable  
In this example, the Norstar Voice Mail module is equipped with four DVCs. The  
DFC is at the right end of the PEB “chain” in slot 7 and the leftmost DVC, DVC 1,  
is at the other end of the chain in slot 3.  
Figure 7 NAM PEB Cable installation example  
DFC  
Slot 7  
DVC4  
Slot 6  
DVC2  
Slot 5  
DVC3  
Slot 4  
DVC1  
Slot 3  
example, the module is equipped with four DVCs. The DFC is at the right end of  
the PEB “chain” in slot 8 and the leftmost DVC, DVC 1, is at the other end of the  
chain in slot 2.  
Figure 8 NAM II PEB Cable installation example  
DFC  
Slot 8  
DVC 4  
Slot 7  
DVC 2  
Slot 5  
SBC  
Slot 4  
DVC 3  
Slot 6  
DVC 1  
Slot 2  
To install the PEB cable:  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
12 Installing the DFC on systems equipped with DVCs  
1. Remove all DVCs from the NAM.  
location of the PEB terminators.  
Figure 9 Digital Voice Card  
PEB connector  
PEB terminator  
XRN1  
PEB terminator  
XRN2  
To remove a PEB terminator, place a flat-head screwdriver between the terminator  
and its socket and gently pry the terminator loose.  
Figure 10 Removing a PEB terminator  
3. Remove both PEB terminators, XRN1 and XRN2, from any remaining DVCs.  
Note: Keep the PEB terminators in a safe place. If the DFC is removed, the  
terminator plugs must be re-installed on the DVCs.  
4. Connect one end of the PEB cable to the PEB socket on the DFC. The PEB  
cable is keyed and can only be installed one way. You must also ensure the  
Pin 1 indicator (colored stripe) is on the edge furthest away from the top of the  
NAM.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the DFC on systems equipped with DVCs 13  
Figure 11 Installing the PEB Cable  
PEB Connector  
Interrupt  
SW2  
SW1  
DFC  
PEB Terminator  
5. Insert the DVCs and connect the PEB cable to each card.  
Note: To ease installation, start with the DVC that is closest to the DFC and  
finish with the DVC farthest away. Also make sure you connect the  
PEB cable before you insert the next DVC.  
6. Fold the PEB cable so it lies flat against the card edges.  
Enabling the FAX software  
The FAX option must be enabled after installing the DFC.  
After FAX capability has been added to Norstar Voice Mail, you can add or  
customize Fax Overflow and Fax-on-demand information. For more information  
about customizing the FAX software, refer to the Norstar Voice Mail FAX Set Up  
and Operation Guide.  
1. Insert the FXENABLE diskette into the floppy disk drive.  
2. Plug in the module and wait for the NAM to boot from the disk. This takes  
approximately three minutes.  
3. After all disk activity has ceased and the light on the floppy disk drive has  
gone out, unplug the NAM and remove the FXENABLE diskette from the  
floppy disk drive. The FAX software is now enabled.  
4. Replace the front cover. Insert the tongues on the bottom of the front cover  
into the module slots.  
5. Fasten the two screws holding the front cover to the module.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
14 Installing the DFC on systems equipped with DVCs  
6. Close the module door.  
Note: To lock the door, turn the lock 90° clockwise until the screwdriver slot  
is horizontal.  
7. Plug the power cord into the AC outlet.  
Adding a Digital Voice Card after FAX is installed  
After you have installed the FAX option on the NAM, the installation of another  
DVC requires a few extra steps. These extra steps are required to remove PEB  
terminators and install the PEB cable.  
To install a DVC:  
1. Warn customers that Norstar Voice Mail will be out of service while you are  
installing the expansion card.  
2. Shutdown the NAM. For more information, refer to "Shutting down the  
3. Remove the NAM power cord from the AC outlet.  
4. Ground yourself by attaching one end of the grounding strap to your wrist and  
the other end to a grounded metal surface.  
6. Set the switches and jumpers on the DVC you are adding. Settings for the  
switches and jumpers are listed in the Norstar Applications Module II  
Installation and Maintenance Manual.  
7. Remove the XRN1 and XRN2 terminators from the DVC you are installing.  
Note: Keep the PEB terminators in a safe place. If the DFC is removed, the  
terminator plugs must be re-installed on the DVCs.  
8. Disconnect the PEB cable from the DVCs already installed in the NAM.  
9. Remove the slot cover screw and the metal slot cover from the slot you are  
adding the new DVC to. DVC slot assignment is listed in the  
Norstar Applications Module II Installation and Maintenance Manual.  
10. Insert the new DVC into the appropriate slot.  
11. Connect the PEB cable to each DVC in the NAM.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the DFC on systems equipped with DVCs 15  
12. Fold the PEB cable so it lies flat against the card edges.  
13. Replace the front cover and close the module door.  
14. Plug the power cord into the AC outlet.  
For a detailed description about installing a DVC, refer to the  
Norstar Applications Module II Installation and Maintenance Manual.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16 Installing the DFC on systems equipped with DVCs  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the DFC on systems equipped with  
a BIC  
3
Only one DFC can be installed in the NAM. The DFC connects to the Media  
Services Bus Expansion Card (BEC) daughterboard attached to the Media Services  
Base Interface Card (BIC) through the PCM Expansion Bus (PEB) cable. This cable  
must be connected from the DFC to the BIC. The PEB cable connects the DFC to  
the BIC to share the ports connected to the Norstar KSU.  
The following section provides step-by-step instructions for the installation of the  
FAX software, a DFC, a BEC and the PEB cable in a Norstar Voice Mail system  
that is equipped with a BIC. For information on installing a DFC in a  
Norstar Voice Mail system equipped with a Digital Voice Card (DVC), refer to  
Figure 12 Digital Fax Card  
PEB Connector  
Interrupt  
SW2  
SW1  
PEB Terminator  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
18 Installing the DFC on systems equipped with a BIC  
Installation overview  
To add Norstar Voice Mail FAX to a system equipped with a BIC you must:  
Remove the BIC from the NAM  
Install the Media Services Bus Expansion Card (BEC) Type A on to the BIC  
Re-install the BIC in the NAM  
Set the BEC jumpers  
Install the DFC  
Connect the DFC to the BIC with the PEB cable  
Enable the FAX software.  
Removing the BIC  
The BIC is removed when a Media Services Bus Expansion Card (BEC) is being  
added to the BIC. The BEC is installed along with the DFC to provide the NAM  
Norstar Voice Mail FAX capability.  
To remove the BIC:  
1. Shutdown the Norstar Voice Mail system. For more information, refer to  
2. Remove the NAM power cord from the AC outlet.  
3. Ground yourself by attaching one end of the grounding strap to your wrist and  
the other end to a grounded metal surface.  
5. If you have a NAM II, disconnect the Serial Port A and Serial Port B  
connectors from the SBC. Disconnect the keyboard/mouse connector from the  
If you have a new NAM, proceed to step 6. The new NAM has 6 expansion  
slots.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the DFC on systems equipped with a BIC 19  
Figure 13 Disconnecting the Serial Ports A and B and the keyboard/ mouse connector  
Keyboard/ mouse  
backplane connector  
Serial Port A Connector  
Serial Port B Connector  
Keyboard/ mouse  
Connector  
6. Locate the BIC and disconnect the fiber cable.The BIC is located in Slot 2 of  
the NAM II and in Slot 4 of the new NAM.  
7. Remove the slot cover screw.  
8. Use both hands to carefully hold the BIC along the top. Lift the BIC straight  
up and out from the module. Sometimes the BIC is tightly seated and difficult  
to remove. You may need to wiggle it out with a slight rocking motion.  
Installing the Media Services Bus Expansion Card (BEC) on the BIC  
A Media Services Bus Expansion Card (BEC) Type A is a daughterboard that is  
installed on the BIC provides the BIC with the ability to connect to a Digital Fax  
Card (DFC).  
Before you begin the installation, you must have #2 Phillips screwdriver.  
To install the BEC:  
1. Ground yourself by attaching one end of the grounding strap to your wrist and  
the other end to a grounded metal surface.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
20 Installing the DFC on systems equipped with a BIC  
2. Place the BIC on a flat surface, with the components facing up. Refer to  
Caution  
Failure to place the BIC on a flat surface may result in serious damage to the  
BIC. While the BIC is out of the NAM, be careful not to slide or catch the back of  
the BIC, this may cause damage to the pins on the back of the board.  
3. Unpack the small plastic bag from the shipping container. Make sure you have  
two screws and two jumpers.  
4. Locate JP1 and JP2 on the BEC. JP1 and JP2 are located next to the PEB  
connector.  
5. Remove the two jumpers from the small plastic bag. Install the two jumpers in  
an “open” position on the bottom pin of JP1 and JP2. For the jumper to be in  
the “open” position, the outside half of each jumper must not cover a pin.  
Figure 14 BEC jumper position  
Jumper  
Jumper  
6. Unpack the BEC daughterboard from the shipping container and antistatic  
bag. The BIC is equipped with two posts at the bottom of the board for  
connection of the BEC daughterboard. Handle the BEC daughterboard by its  
edges at all times. Do not touch any card components. Make sure you have the  
two screws that came with the BEC daughterboard.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the DFC on systems equipped with a BIC 21  
Figure 15 BIC connection points  
Fiber connectors  
Female BEC daughterboard connection points  
Connection post screw hole posts  
PEC Slots (4)  
7. Lightly press the BEC daughterboard down onto the female BEC  
daughterboard connectors on the BIC. The BIC connection screw hole posts  
should be flush with the BEC daughterboard screw holes. For the location of  
8. Before pressing the BEC daughterboard completely down, ensure the male  
BEC daughterboard connectors line up with the female BEC daughterboard  
connection points on the BIC.  
9. Fasten the BEC daughterboard to the BIC connection screw hole posts using  
the two screws provided. For the location of the BIC and BEC daughterboard  
11. Replace the front cover.  
12. Plug the power cord into the AC outlet.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
22 Installing the DFC on systems equipped with a BIC  
Re-installing the BIC in the NAM  
Before you begin to install the BIC, ensure you use an antistatic strap to ground  
yourself.  
To re-install the BIC:  
1. Ground yourself by attaching one end of the grounding strap to your wrist and  
the other end to a grounded metal surface.  
2. Locate expansion slot 2 for a NAM II and slot 4 for a new NAM.  
3. Gently push the large ribbon cables leading to the SBC flat against the  
backplane. This allows for easier installation of the BIC.  
4. Carefully hold the BIC along the top. Insert the card by aligning it between  
the metal groove on one side and the slot opening on the other side.  
Figure 16 Re-installing the BIC in a NAM II  
Slot 2  
BIC  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the DFC on systems equipped with a BIC 23  
Figure 17 Re-installing the BIC in a new NAM  
Slot 4  
BIC  
5. Push the BIC straight back until it fits snugly in place. Ensure the edge  
connector is firmly inserted into the socket.  
6. If you have a NAM II, reconnect the Serial Port A and Serial Port B  
connectors to the SBC. Reconnect the keyboard/mouse connector to the SBC.  
Note: Ensure the keyboard/mouse ribbon cable is still connected to the  
backplane.  
7. Fasten the slot cover screw in the BIC slot cover.  
8. Replace the front cover.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24 Installing the DFC on systems equipped with a BIC  
Installing the DFC in the NAM  
1. Ground yourself by attaching one end of the grounding strap to your wrist and  
the other end to a grounded metal surface.  
2. If you have a NAM II, locate slot 8 on the expansion bus. If you have a new  
NAM, locate slot 1 on the expansion bus. Remove the slot cover screw and  
the metal slot cover from the slot. Keep the metal slot cover and screw. You  
will have to re-install the metal slot cover if you remove the DFC.  
3. Switch SW1 should be set according to the following table:  
Position 8  
State off  
7
6
5
4
3
2
1
on  
off  
off  
on  
on  
on  
on  
4. Switch SW2 should be set according to the following table:  
Position 2  
State on  
1
on  
5. Ensure there is a jumper on position 10 of the INTERRUPT.  
Note: The settings in these table are the default values and should be set  
the location of the switch SW1, SW2 and the INTERRUPT jumpers.  
6. Carefully hold the DFC along the top only. Insert the card by aligning  
between the metal groove on one side and the slot opening on the other side.  
7. Push the DFC straight in until it is snugly in place. Ensure the edge connector  
is firmly inserted into the socket.  
8. Fasten the slot cover screw in the DFC slot cover.  
Connecting the DFC to the BIC with the PEB Cable  
There are no fiber connections to the DFC. The DFC uses the voice ports on the BIC  
to connect the fax ports to fax machines or a call.  
Only one DFC can be installed in a NAM. The DFC connects to the BEC  
daughterboard attached to the BIC through the PCM Expansion Bus (PEB) cable.  
This cable must be connected from the DFC to the BIC. The PEB cable connects  
the DFC to the BIC to share the ports connected to the Norstar KSU.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the DFC on systems equipped with a BIC 25  
Note: The BIC must have a BEC daughterboard installed before it can be  
connected to the DFC. For instructions on installing the BEC  
DFC is at the right end of the PEB “chain” in slot 8 and the BIC is at the other end  
of the chain in slot 2. The three extra connectors on the PEB cable remain empty.  
DFC is in slot 1 and the BIC is at the other end of the chain in slot 4. The three extra  
connectors on the PEB cable remain empty.  
You must use the PEB cable provided in the BEC shipping container. The PEB  
cable is pre-folded for correct installation.  
WARNING  
The microprocessor heat sink may be hot. Pay careful attention not to touch the  
heat sink when installing the PEB cable.  
Figure 18 Connecting the BIC to the DFC in a NAM II  
DFC connector  
PEB Cable  
Empty PEB  
cable connectors  
BIC connector located  
on the BEC daughterboard  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
26 Installing the DFC on systems equipped with a BIC  
Figure 19 Connecting the BIC to the DFC  
DFC connector  
PEB Cable  
DFC in slot 1  
BIC connector located  
on the BEC daughterboard  
BIC in slot 4  
To connect the BIC to the DFC with the PEB cable:  
WARNING  
The microprocessor heat sink may be hot. Pay careful attention not to touch the  
heat sink when installing the PEB cable.  
1. Connect one end of the PEB cable to the PEB socket on the DFC. The PEB  
cable is keyed and can only be installed one way. You must also ensure the  
Pin 1 indicator (colored stripe) is on the edge furthest away from the top of the  
module.  
2. Connect the last connector on the PEB cable to the BIC. The remaining  
connectors on the PEB cable can remain empty and can be folded and gently  
pushed flat against the backplane.  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the DFC on systems equipped with a BIC 27  
Enabling the FAX software  
The FAX option must be enabled after installing the DFC.  
After FAX capability has been added to Norstar Voice Mail, you can add or  
customize Fax Overflow and Fax-on-demand information. For more information  
about customizing the FAX software, refer to the Norstar Voice Mail FAX Set Up  
and Operation Guide.  
1. Insert the FXENABLE diskette into the floppy disk drive.  
2. Plug the power cord into the AC outlet and wait for the NAM to boot from the  
disk. This takes two to three minutes.  
3. When all disk activity has ceased and the light on the floppy disk drive goes  
out, unplug the NAM and remove the FXENABLE diskette from the floppy  
disk drive.  
4. Replace the front cover. Insert the tongues on the bottom of the front cover  
into the module slots.  
5. Fasten the two screws holding the front cover to the module.  
6. Close the module door. To lock the door, turn the lock 90° clockwise until the  
screwdriver slot is horizontal.  
7. Plug the power cord into the AC outlet.  
P0886634 Issue 1.0  
FAX Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
28 Installing the DFC on systems equipped with a BIC  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29  
Tell us what you think...  
This is your document. Nortel wants it to work well for you.  
Please take a few minutes to answer the questions on the other side of this page. Fax it  
back to us at the number provided, or mail it to the address below.  
Your comments will be used to make improvements.  
Thank you. We appreciate your time and consideration.  
Nortel Product Training and Documentation  
Return mail address:  
Documentation User Comments Survey  
Nortel Product Training and Documentation  
P.O. Box 833858  
M/S H300  
Richardson, TX 75083-3858  
USA  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30  
Fax to:  
Documentation User Comments Survey  
Nortel Product Training and Documentation  
1-972-684-8699  
Please circle the most appropriate number on the scale for each question.  
1. Overall, are you satisfied with this document?  
Yes  
2. Is it easy to find information in this document?  
Yes  
7
6
5
4
3
2
1
No  
7
6
5
4
3
2
1
No  
3. Have you found the information in this document to be technically accurate?  
Yes  
4. Is this document clearly written?  
Yes  
7
6
5
4
3
2
1
1
1
1
No  
No  
No  
No  
7
6
5
4
3
2
5. Is the information in this document complete for its purpose?  
Yes  
7
6
5
4
3
2
6. Does this document help you do your job?  
Yes  
7
6
5
4
3
2
Comments:  
Optional:  
Your name___________________________________  
Fax___________________________________  
Company___________________________________  
FAX Installation Guide  
P0886634 Issue 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-800-4 NORTEL  
Norstar is a trademark of Northern Telecom.  
P0886634 Issue 1.0  
Printed in Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Washer W 435 E WPS User Manual
Multiquip SONAR jwn24hscsl User Manual
NETGEAR Network Card XWNB5201 User Manual
Nilfisk Advance America Vacuum Cleaner BRV 900 User Manual
Olympus MP3 Player DS 330 User Manual
Omega Engineering Thermometer HHM57 User Manual
Ozaki Worldwide Speaker System HM050 User Manual
Palsonic Computer Monitor TFTV435 User Manual
Panasonic Outdoor Ceiling Fan FV 15VQ3 User Manual
Pass Labs Stereo Amplifier 5XA305 User Manual