OM-1314
180 846A
February 1997
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Description
Arc Welding Power Source And Wire
Feeder
R
Millermatic Challenger
And M-15 Gun
Visit our website at
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
3
3
4
5
5
5
WARNING
This product, when used
for welding or cutting,
produces fumes or
gases which contain
chemicals known to the
State of California to
cause birth defects and,
in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
8
8
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. Installing Work Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Installing Gas Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Installing Welding Gun And Setting Gun Polarity For Wire Type . . . . . . . . . . . . . . . . . . . . . . .
2-7. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-8. Selecting A Location And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-9. Installing Wire Spool And Adjusting Hub Tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-10. Installing Drive Roll And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-11. Weld Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
9
9
10
11
11
12
13
13
14
15
16
SECTION 3 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SECTION 4 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4-1. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Fuse F1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Short Circuit Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Replacing Gun Contact Tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Unicable Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Cleaning Or Replacing Gun Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Replacing Switch And/Or Head Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Cleaning Or Repairing Drive Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
17
17
18
18
19
20
21
22
SECTION 5 – ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
SECTION 6 – MIG WELDING (GMAW) GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6-1. Typical MIG Process Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Typical MIG Process Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Holding And Positioning Welding Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Conditions That Affect Weld Bead Shape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-5. Gun Movement During Welding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-6. Poor Weld Bead Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-7. Good Weld Bead Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-8. Troubleshooting – Excessive Spatter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-9. Troubleshooting – Porosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-10. Troubleshooting – Excessive Penetration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-11. Troubleshooting – Lack Of Penetration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-12. Troubleshooting – Incomplete Fusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-13. Troubleshooting – Burn-Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-14. Troubleshooting – Waviness Of Bead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-15. Troubleshooting – Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-16. Common MIG Shielding Gases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
25
26
27
28
28
28
29
29
30
30
30
31
31
31
32
SECTION 7 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
OPTIONS AND ACCESSORIES
WARRANTY
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_5/97
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
Y
Marks a special safety message.
. Means “Note”; not safety related.
1-2. Arc Welding Hazards
Y
The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.
D
D
D
If earth grounding of the workpiece is required, ground it directly
with a separate cable – do not use work clamp or work cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D
D
D
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Y
Y
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D
D
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
ELECTRIC SHOCK can kill.
Do not connect more than one electrode or work cable to any
single weld output terminal.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
groundedequipment is a hazard.
D
Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D
D
D
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
FUMES AND GASES can be hazardous.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D
D
Keep your head out of the fumes. Do not breathe the fumes.
D
D
Use AC output ONLY if required for the welding process.
If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
If AC output is required, use remote output control if present on
unit.
D
D
If ventilation is poor, use an approved air-supplied respirator.
D
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D
D
Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
Always verify the supply ground – check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
groundedreceptacle outlet.
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D
D
When making input connections, attach proper grounding conduc-
tor first – double-check connections.
Frequently inspect input power cord for damage or bare wiring –
replace cord immediately if damaged – bare wiring can kill.
Do not weld on coated metals, such as galvanized, lead, or
cadmiumplated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-suppliedrespirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
D
D
D
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
OM-1314 Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
ARC RAYS can burn eyes and skin.
BUILDUP OF GAS can injure or kill.
D
D
Shut off shielding gas supply when not in use.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
Always ventilate confined spaces or use
approved air-supplied respirator.
D
Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
HOT PARTS can cause severe burns.
D
D
D
Wear approved safety glasses with side shields under your
helmet.
D
D
Do not touch hot parts bare handed.
Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
Allow cooling period before working on gun or
torch.
Wear protective clothing made from durable, flame-resistant mate-
rial (leather and wool) and foot protection.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
D
D
Pacemaker wearers keep away.
Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
NOISE can damage hearing.
D
D
D
Protect yourself and others from flying sparks and hot metal.
Do not weld where flying sparks can strike flammable material.
Noise from some processes or equipment can
damagehearing.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D
Wear approved ear protection if noise level is
high.
D
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D
D
Watch for fire, and keep a fire extinguisher nearby.
CYLINDERS can explode if damaged.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D
D
Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D
D
Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D
D
Do not use welder to thaw frozen pipes.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
D
D
Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder – explosion will result.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
FLYING METAL can injure eyes.
D
D
Turn face away from valve outlet when opening cylinder valve.
D
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D
Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
D
Wear approved safety glasses with side
shields even under your welding helmet.
OM-1314 Page 2
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D
Do not install or place unit on, over, or near
combustiblesurfaces.
D
D
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
D
Do not install unit near flammables.
D
Do not overload building wiring – be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D
D
D
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communicationsequipment.
Use equipment of adequate capacity to lift and
support unit.
D
Have only qualified persons familiar with
electronic equipment perform this installation.
If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
D
The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
If notified by the FCC about interference, stop using the
equipmentat once.
OVERUSE can cause OVERHEATING
D
D
Allow cooling period; follow rated duty cycle.
D
D
Have the installation regularly checked and maintained.
Reduce current or reduce duty cycle before
starting to weld again.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
D
Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
D
D
Put on grounded wrist strap BEFORE handling
boards or parts.
ARC WELDING can cause interference.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
D
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
MOVING PARTS can cause injury.
D
Be sure all equipment in the welding area is
electromagneticallycompatible.
D
D
Keep away from moving parts.
Keep away from pinch points such as drive
rolls.
D
D
D
D
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
WELDING WIRE can cause injury.
Be sure this welding machine is installed and grounded
according to this manual.
D
D
Do not press gun trigger until instructed to do
so.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Recommended Safe Practices for the Preparation for Weldingand Cut-
ting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-1314 Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined.Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
4. Keep welding power source and cables as far away from opera-
tor as practical.
5. Connect work clamp to workpiece as close to the weld as possi-
ble.
About Pacemakers:
To reduce magnetic fields in the workplace, use the following
procedures:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-1314 Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT
UTILISATION
som _nd_fre 5/97
1-1. Signification des symboles
SignifieMise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
Y
Identifie un message de sécurité particulier.
. Signifie NOTA ; n’est pas relatif à la sécurité.
1-2. Dangers relatifs au soudage à l’arc
Y
Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
à la section 1-4. Veuillez lire et respecter toutes ces normes de
sécurité.
D
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-
champ les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.
Maintenir solidement en place tous les panneaux et capots.
Y
Y
L’installation, l’utilisation, l’entretien et les réparations ne doi-
vent être confiés qu’à des personnes qualifiées.
Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
Au cours de l’utilisation, tenir toute personne à l’écart et plus par-
ticulièrement les enfants.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimenta-
tion électrique.
D
Arrêter les convertisseurs, débrancher le courant électrique, et dé-
charger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.
D
D
Ne jamais toucher les pièces électriques sous tension.
Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
LES FUMÉES ET LES GAZ peuvent
D
S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact phy-
sique éventuel avec la pièce ou la terre.
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
être dangereux.
Le soudage génère des fumées et des gaz. Leur
D
D
D
D
inhalation peut être dangereux pour votre santé.
D
Eloigner votre tête des fumées. Ne pas respirer
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
les fumées.
D
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimenta-
tion d’air homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consomma-
bles, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxy-
gène provoquant des blessures ou des accidents mortels. S’assu-
rer que l’air de respiration ne présente aucun danger.
Si l’utilisation d’une source électrique àcourant électrique s’avère néces-
saire, se servir de la fonction de télécommande si l’appareil en est équipé.
D
D
Couper l’alimentation ou arrêter le moteur avant de procéder à l’instal-
lation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
Toujours vérifier la terre du cordon d’alimentation – Vérifier et s’assu-
rer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D
D
D
D
D
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-
ment n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.
D
D
En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé – remplacer le cordon immédiatement s’il est
endommagé – un câble dénudé peut provoquer une électrocution.
Mettre l’appareil hors tension quand on ne l’utilise pas.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-
sante ou mal épissés.
D
D
D
D
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct – ne pas utiliser le connecteur de pièce ou le câble de
retour.
OM-1314 Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
LES RAYONS DE L’ARC peuvent pro-
voquer des brûlures dans les yeux et
sur la peau.
LES ACCUMULATIONS DE GAZ ris-
quent de provoquer des blessures ou
même la mort.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.
D
Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
D
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respi-
rateur d’adduction d’air homologué.
D
Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regar-
der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
DES PIÈCES CHAUDES peuvent pro-
voquer des brûlures graves.
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas re-
garder l’arc.
Porter des vêtements de protection constitué dans une matière dura-
ble, résistant au feu (cuir ou laine) et une protection des pieds.
D
D
Ne pas toucher des parties chaudes à mains nues
Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
D
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincel-
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D
D
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.
les, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D
D
D
Se protéger et d’autres personnes de la projection d’étincelles et de
LE BRUIT peut affecter l’ouïe.
métal chaud.
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
Le bruit des processus et des équipements peut affecter
l’ouïe.
Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneuse-
ment avec des protections homologués.
Des étincelles et des matériaux chauds du soudage peuvent facile-
ment passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
D
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
D
D
D
D
Surveiller tout déclenchement d’incendie et tenir un extincteur à proxi-
Si des BOUTEILLES sont endomma-
gées, elles pourront exploser.
mité.
Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endomma-
gée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-
rés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
Brancher le câble sur la pièce le plus près possible de la zone de sou-
dage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’élec-
trocution et d’incendie.
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-
lées.
En cas de non utilisation, enlever la baguette d’électrode du porte-
électrode ou couper le fil à la pointe de contact.
Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans re-
vers, des chaussures hautes et un couvre chef.
Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.
manipuler avec précaution.
D
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étin-
celles et des arcs.
Placer les bouteilles debout en les fixant dans un support stationnai-
re ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres cir-
cuits électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec une
D
D
D
D
D
bouteille.
D
D
D
Ne jamais souder une bouteille pressurisée – risque d’explosion.
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
D
D
D
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
Maintenir le chapeau de protection sur la soupape, sauf en cas d’uti-
lisation ou de branchement de la bouteille.
Lire et suivre les instructions concernant les bouteilles de gaz com-
primé, les équipements associés et les publications P-1 CGA énu-
mérées dans les normes de sécurité.
D
Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques vo-
lantes. Pendant la période de refroidissement des soudures, elles ris-
quent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
OM-1314 Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
Ne pas placer l’appareil sur, au-dessus ou à proxi-
mité de surfaces infllammables.
D
D
Rester à l’écart des organes mobiles comme le
ventilateur.
Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
D
D
Ne pas installer l’appareil à proximité de produits inflammables
Ne pas surcharger l’installation électrique – s”assurer que l’alimen-
tation est correctement dimensionné et protégé avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉ-
QUENCE (H.F.) risque de provoquer
des interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D
Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de ra-
dio–navigationet de communication, les services
de sécurité et les ordinateurs.
D
D
Utiliser l’anneau de levage uniquement pour sou-
lever l’appareil, NON PAS les chariot, les bouteil-
les de gaz ou tout autre accessoire.
D
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installa-
tion.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D
En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.
D
D
Si le FCC signale des interférences, arrêter immédiatement l’appa-
reil.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
D
D
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interfé-
rences éventuelles.
D
D
Prévoir une période de refroidissement, respec-
ter le cycle opératoire nominal.
Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.
LE SOUDAGE À L’ARC risque de
D
Ne pas obstruer les passages d’air du poste.
provoquer des interférences.
LES CHARGES ÉLECTROSTATI-
QUES peuvent endommager les cir-
cuits imprimés.
D
L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit com-
D
D
Établir la connexion avec la barrette de terre
patible électromagnétiquement.
avant de manipuler des cartes ou des pièces.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires tel-
les que le déplacement du poste, l’utilisation de câbles blindés, l’uti-
lisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
D
D
D
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
D
Ne pas s’approcher des organes mobiles.
Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
LES FILS DE SOUDAGE peuvent pro-
voquer des blessures.
D
D
Porteurs de stimulateur cardiaque, restez à dis-
D
D
Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
tance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’appro-
cher des opérations de soudage à l’arc, de gou-
geage ou de soudage par points.
Ne pas diriger le pistolet vers soi, d’autres person-
nes ou toute pièce mécanique en engageant le fil
de soudage.
OM-1314 Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
RecommendedSafe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1
Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiqueset champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitablede réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
2
3
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4
5
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.
OM-1314 Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 2 – INSTALLATION
2-1. Specifications
Amperes Input at
Maximum
Open-Circuit
Voltage DC
Rated Welding
Amperage
Range
Rated Load Out-
put 230 V, 60 Hz,
Single-Phase
Overall
Dimensions
KVA
KW
Weight
Output
Length: 17 in
(432 mm)
130 A @ 20.5 Volts
DC, 30% Duty Cycle
Width: 10 in
(254 mm)
20.5
(0.27)*
4.7
(.05)*
4
95 lb
(43.1 kg)
40 – 170
33
(.04)*
Height: 15-1/2 in
(394 mm)
Solid/
Stainless
Flux Cored/
Aluminum
Calculated Wire
Speed Range At
No Load
Max Wire Feed Speed While Welding
Wire Type
And Dia
.023 – .035 in
.030 – .045 in
126 – 722 IPM
500 IPM
(0.6 – 0.9 mm)
(0.8 – 1.1 mm)
(3.2 – 18.3 m/min)
(12.7 m/min)
* While idling
2-2. Volt-Ampere Curves
Volt-ampere curves show mini-
mum and maximum voltage and
amperage output capabilities of
unit. Curves of other settings fall be-
tween curves shown.
va_curve1 4/95 – SB-180 765
OM-1314 Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
2-3. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
300
250
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
200
150
Y
Exceeding duty cycle can
damage unit or gun and void
warranty.
100
75
50
10
15 20 25 30
40 50 60 70 80 100
% DUTY CYCLE
30% Duty Cycle At 130 Amperes
3 Minutes Welding
7 Minutes Resting
Overheating
A or V
0
15
OR
Reduce Duty Cycle
Minutes
duty1 4/95 – SB-180 844
OM-1314 Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
2-4. Installing Work Clamp
1
2
3
4
Insulator
1
Bolt
Smaller Hole
Work Clamp Tabs
Bend tabs around work cable.
5
6
Work Cable From Unit
Nut
6
2
5
Tools Needed:
3/8, 7/16 in
3
4
Ref. ST-025 190-D
2-5. Installing Gas Supply
Obtain gas cylinder and chain to
running gear, wall, or other station-
ary support so cylinder cannot fall
and break off valve.
1
2
1
2
Cap
Cylinder Valve
Remove cap, stand to side of valve,
and open valve slightly. Gas flow
blows dust and dirt from valve.
Close valve.
3
4
Cylinder
Regulator/Flowmeter
Install so face is vertical.
Gas Hose Connection
3
5
Fitting has 5/8-18 right-hand
threads. Install gas hose.
6
Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour). Check wire manufactur-
er’s recommended flow rate.
Argon Gas
7
8
CO Adapter
2
O-Ring
Install adapter with O-ring between
regulator/flowmeter and
cylinder.
CO
2
OR
6
5
1
2
4
3
7
8
Tools Needed:
5/8, 1-1/8 in
CO Gas
2
ssb3.1* 12/92 – ST-158 697-A
OM-1314 Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
2-6. Installing Welding Gun And Setting Gun Polarity For Wire Type
1
2
3
4
5
Gun Opening
Gun Trigger Receptacle
Gun Securing Nut
Drive Assembly
Gun End
Loosen securing nut. Insert gun
end through opening until it bottoms
against drive assembly. Tighten
nut.
6
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
Close door.
. Follow wire manufacturer’s recommendation.
Solid Steel Or
Aluminum Wires
(GMAW–With Gas)
Flux Cored Wires
(FCAW–Without Gas)
Straight Polarity
DCEN
Reverse Polarity
DCEP
1
2
Front Panel Openings
3
4
6
5
Tools Needed:
5/16 in
ST-149 328-B / Ref. ST-159 270
OM-1314 Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
2-7. Electrical Service Guide
230
20.5
25
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC)
14
64 (19)
14
S-0092-J
2-8. Selecting A Location And Connecting Input Power
1
Rating Label
Supply correct input power.
2
3
Plug
Receptacle
Connect plug to receptacle.
Line Disconnect Device
See Section 2-7.
Special installation may be
4
18 in (457 mm) of
space for airflow
4
Y
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
L1
L2
Y
Always connect
grounding
conductor first.
= GND/PE
3
L1
L2
1
2
230 VAC, 1
Y
Do not move or operate unit
where it could tip.
ssb2.2* 1/94 – ST-801 504
OM-1314 Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
2-9. Installing Wire Spool And Adjusting Hub Tension
1 Lb Wire Spool
Standard Wire Spool
Standard Wire Reel
Part No. 183 312
Part No. 135 615
When a slight force is needed
to turn spool, tension is set.
Tools Needed:
15/16 in
S-0499
OM-1314 Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
2-10. Installing Drive Roll And Threading Welding Wire
Install drive roll onto shaft with de-
sired groove in, and one set screw
facing flat side of shaft. Tighten both
set screws.
1
Install drive roll.
For Flux Cored Wire
For Solid Wire
3
Pull and hold wire; cut off end.
2
Open pressure assembly.
6 in
(150 mm)
4
Push wire thru guides into gun;
continue to hold wire.
5
Close and tighten pressure assembly,
and let go of wire.
6
Remove gun nozzle and contact tip.
8
Press gun trigger until wire comes out
of gun.
7
Turn power On.
9
Reinstall contact tip and nozzle.
10 Feed wire to check drive roll
pressure. Tighten knob enough to
prevent slipping. Cut off wire; leave
1/4–1/2 in (6–13 mm). Close and
latch door.
Tools Needed:
WOOD
Ref. ST-149 266-B / Ref. ST-149 326-B / Ref. 150 093-A / Ref. 180 968 / S-0627-A
OM-1314 Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
2-11. Weld Parameters
Material Thickness
Wire Type,
Shielding Gas,
And Flow Rate
Wire
Diameter
(inch)
Operator
Controls
1/4 in.
3/16 in.
1/8 in.
14 ga.
16 ga.
18 ga.
20 ga.
22 ga.
(6.4 mm) (4.8 mm) (3.2 mm)
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
Voltage Tap
Wire Speed
– –
– –
6
5
70
5
4
60
4
3
50
3
3
30
3
2
20
2
2
5
1
.023
.030
.035
.023
.030
.035
.030
.035
.023
.030
0
E70S-6
1
– –
– –
– –
– –
1
CO
2
60
6
45
5
40
4
35
3
30
2
25
2
20
2
20 cfh+
30
6
20
5
20
4
20
3
20
3
15
2
5
2
100
6
90
5
75
4
60
3
50
3
35
2
20
1
10
1
E70S-6
75% Argon
25% CO
20 cfh+
2
70
6
60
5
50
5
40
4
30
3
20
2
10
2
0
– –
– –
– –
– –
– –
– –
3
50
6
45
6
40
5
30
4
25
3
25
2
10
2
50
6
45
6
30
5
20
4
20
3
10
– –
– –
3
10
– –
– –
3
E71T-GS
Flux Core
40
– –
– –
– –
– –
40
5
30
4
20
4
20
3
ER 308
Stainless Steel
Tri-Mix
100
6
90
5
75
4
60
3
50
3
40
– –
– –
25
– –
– –
20 cfh+
75
70
60
50
40
*Do not change Voltage switch position while welding. Wire Speed value in Table is a starting value only, and Wire Speed control setting can be fine
tuned during welding.
S-181 186
SECTION 3 – OPERATION
3-1. Controls
1
Wire Speed Control
Use control to select a wire feed
speed. As Voltage switch setting in-
creases, wire speed range also in-
creases.
1
2
2
Voltage Switch
The higher the selected number,
the thicker the material that can be
welded. Do not switch while
welding.
3
Power Switch
3
Ref. ST-182 986-B
OM-1314 Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 4 – MAINTENANCE & TROUBLESHOOTING
4-1. Maintenance
. Maintain more often
Y
Disconnectpower
before maintaining.
during severe conditions.
3 Months
Repair Or
Clean And
Tighten
Weld
Replace
Cracked
Cables
Replace
Damaged Or
Unreadable
Labels
Connections
And Cords
6 Months
Blow Out Or
Vacuum Inside
stat_maint – 2/96
4-2. Fuse F1
Y
Turn Off unit, disconnect in-
put power. Unlatch door and
remove wrapper.
1
1
2
Circuit Board PC1
Fuse F1 (See Parts List For
Rating)
If F1 opens, wire drive motor shuts
down. Replace F1 if open.
2
Reinstall wrapper, and latch door.
Tools Needed:
3/8 in
Ref. ST-801 552
4-3. Short Circuit Shutdown
If contact tip is shorted and sticks to workpiece, the unit shuts down, but fan runs. To resume operation, release gun
trigger, turn Off unit, and remove contact tip from workpiece. Check contact tip and replace if damaged. Turn On unit to
continue operation.
OM-1314 Page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
4-4. Replacing Gun Contact Tip
Y
Turn Off power before
replacing contact tip.
1
2
Nozzle
Contact Tip
Cut off welding wire at contact tip.
Remove nozzle.
Remove contact tip and install new
contact tip. Reinstall nozzle.
2
1
Tools Needed:
ST-149 326-B
4-5. Unicable Repair
To repair or replace unicable, order Unicable Clamp Kit, part number 172 017. Kit includes all required instructions,
clamps, inner support tube, compression clip, switch leads, and connectors.
OM-1314 Page 18
Download from Www.Somanuals.com. All Manuals Search And Download.
4-6. Cleaning Or Replacing Gun Liner
Tools Needed:
Y
Disconnect gun from unit.
3/8 in
Head Tube
Remove nozzle, contact tip,
adapter, and wire outlet guide.
3/8 in
Wire Outlet Guide
Remove liner.
Lay gun cable out straight
before installing new liner.
To Reassemble Gun:
Insert new liner.
Install and tighten wire outlet guide.
Cut liner off 3/4 in (20 mm) (3/8 in
[9.5 mm] for aluminum) from head
tube.
Blow out gun casing.
Install adapter, contact tip, and
nozzle.
Ref. ST-800 797-A
OM-1314 Page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
4-7. Replacing Switch And/Or Head Tube
Y
Disconnect gun from unit.
3
Slide handle.
2
Remove switch housing. Note: If installing new
switch, push switch lead connectors onto terminal of
new switch (polarity is not important). Install switch
back into handle, and secure with handle locking nut.
If replacing head tube, continue to end of figure.
1
Remove handle
locking nut.
4
Secure head
tube in vice.
5
Remove shock washers
from front and rear of
head tube.
6
Loosen jam nut. Remove
from vice and turn head
tube out by hand.
Do not disturb cable connection between
cable connector and connector nut.
7
Install both existing shock washers
to new head tube and hand-tighten
head tube into connector cable.
8
Place head tube in vice and tighten
to within 1/8 in (3.2 mm) spacing be-
tween connector cable and body.
9
Remove from vice. Reposition
handle and install switch housing.
Secure with handle locking nut.
Tools Needed:
3/4 in
Ref. ST-800 795-A
OM-1314 Page 20
Download from Www.Somanuals.com. All Manuals Search And Download.
4-8. Cleaning Or Repairing Drive Assembly
Y
Turn Off power before
cleaning or repairing drive
assembly.
1
2
Wire Spool
Nozzle
Cut welding wire off at nozzle.
Retract wire onto spool and secure.
3
4
5
6
7
Pressure Roll Arm
Cotter Pin
Pin
Screw
Bearing
Remove bearing. Install new bear-
ing and secure with screw. Reinstall
arm onto pin and secure with cotter
pin.
8
9
Setscrew
Drive Roll
Remove drive roll.
1
Push drive roll onto shaft with
desired groove in. Turn drive roll so
one setscrew faces flat side of
shaft, and tighten both setscrews.
10 Wire Inlet Guide
2
Remove guide by pressing on
barbed area or cutting off one end
near housing and pulling it out of
hole. Push new guide into hole from
rear until it snaps in place.
Close door.
3
5
6
7
8
4
9
10
8
Tools Needed:
5/64 in
Ref. ST-150 093-A / ST-149 266-B
OM-1314 Page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
4-9. Troubleshooting
Welding Trouble
Remedy
Secure power cord plug in receptacle (see Section 2-8).
Check and replace power switch if necessary.
No weld output; wire does not feed.
Check fuse F1, and replace if necessary (see Section 4-2).
Replace building line fuse or reset circuit breaker if open (see Section 2-8).
Secure gun trigger plug in receptacle or repair leads, or replace trigger switch (see Section 2-6 and/or
4-7).
ThermostatTP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled
(see Section 2-3).
No weld output; wire feeds.
Connect work clamp to get good metal to metal contact.
Replace contact tip (see Section 4-4).
Low weld output.
Connect unit to proper input voltage or check for low line voltage (see Section 2-8).
Readjust front panel settings (see Section 3-1).
Low, high, or erratic wire speed.
Change to correct groove in drive roll (see Section 2-10).
Readjust drive roll pressure (see Section 2-10).
Replace inlet guide, contact tip, and/or liner if necessary (see Sections 4-8, 4-4 and/or 4-6).
Wire Drive/Gun Trouble
Remedy
Straightengun cable and/or replace damaged parts (see Section 4-6).
Adjust drive roll pressure (see Section 2-10).
Electrode wire feeding stops during
welding.
Readjust hub tension (see Section 2-9).
Replace contact tip if blocked (see Section 4-4).
Clean or replace wire inlet guide or liner if dirty or plugged (see Section 4-8, and Section 4-6).
Replace drive roll if worn or slipping (see Section 2-10).
Secure gun trigger plug in receptacle or repair leads, or replace trigger switch (see Section 2-6 and/or
4-7).
Check and clear any restrictions at drive assembly and liner (see Section 4-8, and Section 4-6).
Have nearest Factory Authorized Service Agent check drive motor.
Check relay CR1, and replace if necessary.
OM-1314 Page 22
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 5 – ELECTRICAL DIAGRAM
SB-180 784-B
Figure 5-1. Circuit Diagram
OM-1314 Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 6 – MIG WELDING (GMAW) GUIDELINES
6-1. Typical MIG Process Connections
Y
Weld current can damage
electronic parts in vehicles.
Disconnect both battery
cables before welding on a
vehicle. Place work clamp as
close to the weld as possible.
Regulator/
Flowmeter
Wire Feeder/
Power Source
Gun
Shielding Gas
Gas
Workpiece
Work Clamp
light mig 5/967 / ST-801 909
OM-1314 Page 24
Download from Www.Somanuals.com. All Manuals Search And Download.
6-2. Typical MIG Process Control Settings
These settings are guidelines only. Material and wire type, joint design, fitup,
position, shielding gas, etc. affect settings. Test welds to be sure they comply to
specifications.
NOTE
Material thickness determines weld
parameters.
1/8 or
.125 in
Convert Material
Thickness to
Amperage (A)
(.001 in = 1 ampere)
.125 in = 125 A
Wire Size
Amperage Range
.035 in
.023 in
.030 in
.035 in
30 – 90 A
40 – 145 A
50 – 180 A
Select Wire Size
Select Wire Speed
(Amperage)
Wire
Size
Wire Speed
(Approx.)
Recommendation
.023 in
.030 in
.035 in
3.5 in per ampere
2 in per ampere
1.6 in per ampere
3.5 x 125 A = 437 ipm
2 x 125 A = 250 ipm
1.6 x 125 A = 200 ipm
125 A based on 1/8 in
material thickness
ipm = inch per minute
Low voltage: wire stubs into work
High voltage: arc is unstable (spatter)
Select Voltage
Set voltage midway between high/low voltage.
Wire speed (amperage) controls weld pe-
netration(wire speed = burn-off rate)
Voltage controls height and width of
weld bead.
Ref. ST-801 865
OM-1314 Page 25
Download from Www.Somanuals.com. All Manuals Search And Download.
6-3. Holding And Positioning Welding Gun
Welding wire is energized when gun trigger is pressed. Before lowering helmet and
pressing trigger, be sure wire is no more than 1/2 in (13 mm) past end of nozzle,
and tip of wire is positioned correctly on seam.
NOTE
1
Hold Gun and Control Gun
Trigger
1
2
3
4
Workpiece
Work Clamp
3
Electrode Extension (Stickout)
1/4 to 1/2 in (6 To 13 mm)
2
5
Cradle Gun and Rest Hand on
Workpiece
5
4
0°-15°
90°
90°
End View Of Work Angle
Side View Of Gun Angle
GROOVE WELDS
0°-15°
45°
45°
End View Of Work Angle
Side View Of Gun Angle
FILLET WELDS
S-0421-A
OM-1314 Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
6-4. Conditions That Affect Weld Bead Shape
Weld bead shape depends on gun angle, direction of travel, electrode extension
(stickout), travel speed, thickness of base metal, wire feed speed (weld current),
and voltage.
NOTE
10°
Push
10°
Perpendicular
Drag
GUN ANGLES AND WELD BEAD PROFILES
Short
Normal
Long
ELECTRODE EXTENSIONS (STICKOUT)
Short
Normal
Long
FILLET WELD ELECTRODE EXTENSIONS (STICKOUT)
Slow
Normal
Fast
GUN TRAVEL SPEED
S-0634
OM-1314 Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
6-5. Gun Movement During Welding
Normally, a single stringer bead is satisfactory for most narrow groove weld joints;
however, for wide groove weld joints or bridging across gaps, a weave bead or
multiple stringer beads works better.
NOTE
1
2
3
Stringer Bead – Steady
Movement Along Seam
1
2
Weave Bead – Side To Side
Movement Along Seam
Weave Patterns
Use weave patterns to cover a wide
area in one pass of the electrode.
3
S-0054-A
6-6. Poor Weld Bead Characteristics
1
2
3
4
5
Large Spatter Deposits
Rough, Uneven Bead
1
Slight Crater During Welding
Bad Overlap
Poor Penetration
2
4
3
5
S-0053-A
6-7. Good Weld Bead Characteristics
1
2
3
Fine Spatter
Uniform Bead
Moderate Crater During
Welding
1
Weld a new bead or layer for each
1/8 in (3.2 mm) thickness in metals
being welded.
4
5
No Overlap
Good Penetration into Base
Metal
2
4
3
5
S-0052-B
OM-1314 Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
6-8. Troubleshooting – Excessive Spatter
Excessive Spatter – scattering of molten metal particles that
cool to solid form near weld bead.
S-0636
Possible Causes
Wire feed speed too high.
Corrective Actions
Select lower wire feed speed.
Select lower voltage range.
Use shorter electrode extension (stickout).
Voltage too high.
Electrode extension (stickout) too long.
Workpiece dirty.
Remove all grease, oil, moisture, rust, paint, undercoating, and dirt from work surface before welding.
Increase flow of shielding gas at regulator/flowmeter and/or prevent drafts near welding arc.
Use clean, dry welding wire.
Insufficient shielding gas at welding arc.
Dirty welding wire.
Eliminate pickup of oil or lubricant on welding wire from feeder or liner.
6-9. Troubleshooting – Porosity
Porosity – small cavities or holes resulting from gas pockets
in weld metal.
S-0635
Possible Causes
Corrective Actions
Insufficient shielding gas at welding arc.
Increase flow of shielding gas at regulator/flowmeter and/or prevent drafts near welding arc.
Remove spatter from gun nozzle.
Check gas hoses for leaks.
Place nozzle 1/4 to 1/2 in (6-13 mm) from workpiece.
Hold gun near bead at end of weld until molten metal solidifies.
Use welding grade shielding gas; change to different gas.
Use clean, dry welding wire.
Wrong gas.
Dirty welding wire.
Eliminate pick up of oil or lubricant on welding wire from feeder or liner.
Workpiece dirty.
Remove all grease, oil, moisture, rust, paint, coatings, and dirt from work surface before welding.
Use a more highly deoxidizing welding wire (contact supplier).
Welding wire extends too far out of nozzle. Be sure welding wire extends not more than 1/2 in (13 mm) beyond nozzle.
6-10. Troubleshooting – Excessive Penetration
Excessive Penetration – weld metal melting through base metal
and hanging underneath weld.
Excessive Penetration Good Penetration
S-0639
Possible Causes
Excessive heat input.
Corrective Actions
Select lower voltage range and reduce wire feed speed.
Increase travel speed.
OM-1314 Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
6-11. Troubleshooting – Lack Of Penetration
Lack Of Penetration – shallow
fusion between weld metal and
base metal.
Lack of Penetration Good Penetration
S-0638
Possible Causes
Corrective Actions
Improper joint preparation.
Improper weld technique.
Material too thick. Joint preparation and design must provide access to bottom of groove while
maintaining proper welding wire extension and arc characteristics.
Maintain normal gun angle of 0 to 15 degrees to achieve maximum penetration.
Keep arc on leading edge of weld puddle.
Be sure welding wire extends not more than 1/2 in (13 mm) beyond nozzle.
Select higher wire feed speed and/or select higher voltage range.
Reduce travel speed.
Insufficient heat input.
6-12. Troubleshooting – Incomplete Fusion
Incomplete Fusion – failure of weld metal to fuse completely with
base metal or a preceeding weld bead.
S-0637
Possible Causes
Workpiece dirty.
Corrective Actions
Remove all grease, oil, moisture, rust, paint, undercoating, and dirt from work surface before
welding.
Insufficient heat input.
Select higher voltage range and/or adjust wire feed speed.
Place stringer bead in proper location(s) at joint during welding.
Adjust work angle or widen groove to access bottom during welding.
Momentarily hold arc on groove side walls when using weaving technique.
Keep arc on leading edge of weld puddle.
Improper welding technique.
Use correct gun angle of 0 to 15 degrees.
6-13. Troubleshooting – Burn-Through
Burn-Through– weld metal melting completely through base metal
resulting in holes where no metal remains.
S-0640
Possible Causes
Corrective Actions
Excessive heat input.
Select lower voltage range and reduce wire feed speed.
Increase and/or maintain steady travel speed.
OM-1314 Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
6-14. Troubleshooting – Waviness Of Bead
Waviness Of Bead – weld metal that is not parallel and does not cover
joint formed by base metal.
S-0641
Possible Causes
Welding wire extends too far out of nozzle. Be sure welding wire extends not more than 1/2 in (13 mm) beyond nozzle.
Unsteady hand. Support hand on solid surface or use two hands.
Corrective Actions
6-15. Troubleshooting – Distortion
Distortion – contraction of weld metal during welding that forces
base metal to move.
Base metal moves
in the direction of
the weld bead.
S-0642
Possible Causes
Corrective Actions
Excessive heat input.
Use restraint (clamp) to hold base metal in position.
Make tack welds along joint before starting welding operation.
Select lower voltage range and/or reduce wire feed speed.
Increase travel speed.
Weld in small segments and allow cooling between welds.
OM-1314 Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
6-16. Common MIG Shielding Gases
This is a general chart for common gases and where they are used. Many different combinations (mixtures) of
shielding gases have been developed over the years. The most commonly used shielding gases are listed in the
following table.
Application
Gas
Short Circuiting
Stainless Steel
Short Circuiting
Aluminum
Spray Arc Steel
Short Circuiting Steel
Argon
All Positions
1
2
Argon + 25% CO
Flat & Horizontal Fillet
All Positions
All Positions
All Positions
2
1
CO
Flat & Horizontal Fillet
2
3
Tri-Mix
All Positions
1
2
3
Globular Transfer
Single Pass Welding Only
90% HE + 7-1/2% AR + 2-1/2% CO
2
OM-1314 Page 32
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
OM-1314 Page 33
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7 – PARTS LIST
. Hardware is common and
not available unless listed.
ST-801 633
Figure 7-1. Main Assembly
OM-1314 Page 34
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-1. Main Assembly
Quantity
. . . 1 . . . . . . . . . . . . . . 131 315 . . DRIVE ASSEMBLY, wire (Fig 7-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . . . . . . . . . . 010 909 . . NUT, 375-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 3 . . . . . . . . . . . . . . 010 910 . . WASHER, flat .406 ID x 0.81 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 4 . . . . . . . . . . . . . . 073 355 . . SPRING, cprsn .625 OD x 0.93 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 5 . . . . . . . . . . . . . . . 111 998 . . PIN, cotter hair .120dia x 2.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . . . . . . . . . . . . 111 929 . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . . . . . . . 147 562 . . BAFFLE, center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 8 . . . . . . FM . . . . 117 014 . . MOTOR, fan 230V 50/60 Hz 2600RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . . . . . . . . . . 005 656 . . BLADE, fan 6.000 4wg 30 deg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . CR2 . . . 108 358 . . CONTACTOR, def prp 25A 2P 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . SR2 . . . 180 791 . . RECTIFIER, si 1PH 140A 200PIV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 12 . . . . . . . . . . . . . . 147 461 . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 13 . . . . . . R1 . . . . 000 101 . . RHEOSTAT, WW 50W 16 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 14 . . . . . . S2 . . . . 180 777 . . SWITCH, rotary 6 pin 1P 600V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . RC3 . . . 048 282 . . RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . . . . . . . . . 147 560 . . PANEL, side lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 17 . . . . . . T1 . . . . 180 786 . . TRANSFORMER, power main . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 18 . . . . . PC1 . . . 172 543 . . CIRCUIT CARD, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 19 . . . . . . F1 . . . . 073 426 . . . . FUSE, mintr slo-blo 5A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 20 . . . . . CR2 . . . 080 388 . . . . RELAY, encl 24VAC 3PDT 10A/120VAC . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 173 299 . . CLIP, hold-down relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . . . . . . . . . . 134 201 . . STAND-OFF, support PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 22 . . . . . . . . . . . . . . 147 563 . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 23 . . . . . . . . . . . . . . 089 899 . . LATCH, slide flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 24 . . . . . . . . . . . . . . 134 327 . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 25 . . . . . . . . . . . . . . 126 415 . . CLAMP, saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 26 . . . . . . . . . . . . . . 126 416 . . HANDLE, molded plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 27 . . . . . . . . . . . . . . . 111 443 . . BUSHING, strain relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 28 . . . . PLG1 . . . 152 118 . . CORD SET, 250V 6-50P 12GA 3/c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 29 . . . . . . . . . . . . . . 605 227 . . NUT, 750-14 knurled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 30 . . . . . . . . . . . . . . 147 462 . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 31 . . . . . GS1 . . . 128 751 . . VALVE, 230VAC 2 way . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 32 . . . . . R2,3 . . . 181 649 . . RESISTOR, WW fxd 40W 25 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 33 . . . . . VR1 . . . 090 288 . . VARISTOR w/TERMINALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 34 . . . . . . C1 . . . . 162 245 . . CAPACITOR, elctlt 140000uf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 35 . . . . . . . . . . . . . . 022 160 . . CLAMP, capacitor 3.000dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 36 . . . . . . Z1 . . . . 180 793 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 37 . . . . . . . . . . . . . . 147 566 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 38 . . . . . . . . . . . . . . 147 548 . . NUT, speed push-on type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
. . . 39 . . . . . . . . . . . . . . 146 753 . . BEZEL, front/rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 40 . . . . . . . . . . . . . . 010 368 . . CLAMP, work 200A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 41 . . . . . . . . . . . . . . 026 843 . . INSULATOR, vinyl blk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 42 . . . . . . . . . . . . . . 600 325 . . CABLE, weld cop strd No. 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16ft
. . . 43 . . . . . . . . . . . . . . 169 903 . . M-15 GUN, (Fig 7-2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 44 . . . . . . . . . . . . . . . 111 644 . . BUSHING, strain relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 45 . . . . . . S1 . . . . 116 830 . . SWITCH, rocker DPST 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 46 . . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . . . . 1
. . . 47 . . . . . . . . . . . . . . . . . . . . . . . . . KNOB, pointer (included w/Item 14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 48 . . . . . . . . . . . . . . 097 922 . . KNOB, pointer .875dia x .250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 49 . . . . . TE1 . . . . 122 385 . . TERMINAL ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 50 . . . . . . . . . . . . . . 174 504 . . . . LINK, jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . 113 149 . . CONNECTOR, rect 156 14skt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 110 160 . . CONNECTOR, rect 156 6skt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 000 067 . . TIP, contact scr .030 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 000 068 . . TIP, contact scr .035 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 087 299 . . TIP, contact scr .023 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 166 575 . . WRENCH, hex .078 across . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 135 615 . . BUSHING, nylon .390 ID x .750 OD x .750 lg . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . 183 312 . . ADAPTER RING, wire spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1314 Page 35
Download from Www.Somanuals.com. All Manuals Search And Download.
. Hardware is common and
not available unless listed.
1
2
3
4
5
6
7
6
8
9
10
11
13
14
15
25
27
26
12*
20
23
22
24
16
18
21
28
17
17
19
8
9
10
11
16
18
*Includes Item 17
19
ST-801 140
Figure 7-2. M-15 Gun
OM-1314 Page 36
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Part
No.
Description
Quantity
169 589
Figure 7-2. M-15 Gun (Fig 7-1 Item 43)
. . . 1 . . . . . 169 715 . . NOZZLE, slip type .500 orf flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 1 . . . ♦176 237 . . NOZZLE, spot flat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 1 . . . ♦176 239 . . NOZZLE, spot inside corner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 1 . . . ♦176 241 . . NOZZLE, spot outside corner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . ♦087 299 . . TIP, contact scr .023 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . 000 067 . . TIP, contact scr .030 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . ♦000 068 . . TIP, contact scr .035 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 3 . . . . . 169 716 . . ADAPTER, contact tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 4 . . . . . 170 470 . . RING, retaining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 5 . . . . . 170 471 . . O-RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . . 169 717 . . WASHER, shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 7 . . . . . 169 718 . . TUBE, head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 8 . . . . . 169 738 . . NUT, locking handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 9 . . . . . 169 719 . . NUT, jam (gun end) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . 169 732 . . NUT, jam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . 169 720 . . CONNECTOR, cable (gun end) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . 169 733 . . CONNECTOR, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . 169 721 . . NUT, connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 12 . . . . . 172 017 . . M15 UNICABLE CLAMP KIT, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 13 . . . . . 169 735 . . . . CLIP, compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 14 . . . . . 169 742 . . . . TUBE, support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . 169 743 . . . . CLAMP, inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . 169 740 . . . . CLAMP, jacket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 17 . . . . . 169 746 . . . . CONNECTOR, switch lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 18 . . . . . 169 737 . . HANDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 19 . . . . . 169 741 . . STRAIN RELIEF, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 20 . . . . . 180 433 . . CORD, trigger assembly (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . 180 551 . . . . BLOCK, terminal rear inc/dec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 22 . . . . . 180 427 . . . . CORD, trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 23 . . . . . 173 521 . . CONNECTOR, feeder (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 24 . . . . . 079 974 . . . . O-RING, .500 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 25 . . . ♦172 257 . . KIT, liner monocoil .023/.025 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 25 . . . . . 172 258 . . KIT, liner monocoil .030/.035 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 26 . . . . . 079 975 . . . . O-RING, .187 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 27 . . . . . 169 723 . . GUIDE, outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 28 . . . . . 169 739 . . SWITCH, trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
♦OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1314 Page 37
Download from Www.Somanuals.com. All Manuals Search And Download.
Item Dia.
No. Mkgs.
Part
No.
Description
Quantity
Figure 7-3. Drive Assembly, Wire (Fig 7-1 Item 1)
. . . 1 . MOT . 173 446 . . . MOTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . . . . 129 893 . . . INSULATOR, housing drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 3 . . . . . . . . 126 838 . . . DRIVE ASSEMBLY, wire (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 4 . . . . . . . . 090 416 . . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 5 . . . . . . . . 124 817 . . . . HOUSING, wire drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . . . . . 151 828 . . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . 112 031 . . . . LEVER, pressure roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 8 . . . . . . . . 090 443 . . . . BEARING, ball rdl sgl row .866 OD x .447 width x .315 bore (consisting of) . . 1
. . . . . . . . . . . . . . 111 622 . . . . . . SPACER, bearing .196 ID x .310 OD x .500 collar . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . . . . 010 224 . . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . . . . 058 549 . . . . GUIDE, wire inlet 1/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . . . . 085 242 . . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 12 . . . . . . . . 085 244 . . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 13 . . . . . . . . 090 415 . . . . SPRING, cprsn .720 OD x .070 wire x 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 14 . . . . . . . . 092 237 . . . . KNOB, adj tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . . . . 119 028 . . . ROLL, drive V groove combination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . . . 602 169 . . . SCREW, set stl sch 8-32 x .187 cup point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 17 . . . . . . . . 114 415 . . . SCREW, mach stl phflh 10-24 x .625 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . 166 575 . . . WRENCH, hex .078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. Hardware is common and
2
not available unless listed.
1
3
4
5
Includes Items
6 thru 14
17
14
13
12
11
6
7
8
SC-121 448-C
10
9
16
15
Figure 7-3. Drive Assembly, Wire
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1314 Page 38
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective January 1, 2000
(Equipment with a serial number preface of “LA” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
Warranty Questions?
LIMITED WARRANTY – Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants
to its original retail purchaser that new Miller equipment sold
after the effective date of this limited warranty is free of defects
in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
Call
1-800-4-A-MILLER
for your local
Miller distributor.
*
*
*
*
*
Remote Controls
Accessory Kits
Replacement Parts (No labor)
Spoolmate 185 & Spoolmate 250
Canvas Covers
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Your distributor also gives
you ...
Miller’s True Blue Limited Warranty shall not apply to:
1. Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, slip rings,
relays or parts that fail due to normal wear.
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser, or
one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.
2. Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Support
3. Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
1. 5 Years Parts – 3 Years Labor
*
*
Original main power rectifiers
Inverters (input and output rectifiers only)
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
2. 3 Years — Parts and Labor
*
*
*
*
*
*
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
Semi-Automatic and Automatic Wire Feeders
Inverter Power Supplies
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods
at customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
Intellitig
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by
the engine manufacturer.)
3. 1 Year — Parts and Labor
*
*
DS-2 Wire Feeder
Motor Driven Guns (w/exception of Spoolmate
185 & Spoolmate 250)
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers
Positioners and Controllers
Automatic Motion Devices
RFCS Foot Controls
Induction Heating Power Sources
Water Coolant Systems
HF Units
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
Grids
Maxstar 140
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
Spot Welders
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
Load Banks
Miller Cyclomatic Equipment
Running Gear/Trailers
Plasma Cutting Torches (except APT & SAF
Models)
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
*
Field Options
(NOTE: Field options are covered under True
Blue for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
4. 6 Months — Batteries
5. 90 Days — Parts
*
*
MIG Guns/TIG Torches
Induction Heating Coils and Blankets
miller_warr 7/00
Download from Www.Somanuals.com. All Manuals Search And Download.
Owner’s Record
Please complete and retain with your personal records.
Model Name
Purchase Date
Distributor
Address
Serial/Style Number
(Date which equipment was delivered to original customer.)
City
State
Zip
For Service
to locate a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
International Headquarters–USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
European Headquarters –
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
Welding Process Handbooks
Contact the Delivering Carrier for:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.
PRINTED IN USA
2000 Miller Electric Mfg. Co. 6/00