Miller Electric Welder M 15 User Manual

OM-1314  
180 846A  
February 1997  
Processes  
MIG (GMAW) Welding  
Flux Cored (FCAW) Welding  
Description  
Arc Welding Power Source And Wire  
Feeder  
R
Millermatic Challenger  
And M-15 Gun  
Visit our website at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . .  
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .  
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Dangers relatifs au soudage à larc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
1
3
3
4
5
5
5
WARNING  
This product, when used  
for welding or cutting,  
produces fumes or  
gases which contain  
chemicals known to the  
State of California to  
cause birth defects and,  
in some cases, cancer.  
(California Health &  
Safety Code Section  
25249.5 et seq.)  
1-3. Dangers supplémentaires en relation avec linstallation, le fonctionnement  
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7
8
8
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 2 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-2. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-3. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-4. Installing Work Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-5. Installing Gas Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-6. Installing Welding Gun And Setting Gun Polarity For Wire Type . . . . . . . . . . . . . . . . . . . . . . .  
2-7. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-8. Selecting A Location And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-9. Installing Wire Spool And Adjusting Hub Tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-10. Installing Drive Roll And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-11. Weld Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
9
9
9
10  
11  
11  
12  
13  
13  
14  
15  
16  
SECTION 3 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
3-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
SECTION 4 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
4-1. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-2. Fuse F1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-3. Short Circuit Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-4. Replacing Gun Contact Tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-5. Unicable Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-6. Cleaning Or Replacing Gun Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-7. Replacing Switch And/Or Head Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-8. Cleaning Or Repairing Drive Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-9. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
17  
17  
17  
18  
18  
19  
20  
21  
22  
SECTION 5 – ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
SECTION 6 – MIG WELDING (GMAW) GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
6-1. Typical MIG Process Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-2. Typical MIG Process Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-3. Holding And Positioning Welding Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-4. Conditions That Affect Weld Bead Shape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-5. Gun Movement During Welding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-6. Poor Weld Bead Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-7. Good Weld Bead Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-8. Troubleshooting Excessive Spatter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-9. Troubleshooting Porosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-10. Troubleshooting Excessive Penetration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-11. Troubleshooting Lack Of Penetration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-12. Troubleshooting Incomplete Fusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-13. Troubleshooting Burn-Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-14. Troubleshooting Waviness Of Bead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-15. Troubleshooting Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6-16. Common MIG Shielding Gases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
24  
25  
26  
27  
28  
28  
28  
29  
29  
30  
30  
30  
31  
31  
31  
32  
SECTION 7 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34  
OPTIONS AND ACCESSORIES  
WARRANTY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING  
som _nd_5/97  
1-1. Symbol Usage  
Means Warning! Watch Out! There are possible hazards  
with this procedure! The possible hazards are shown in  
the adjoining symbols.  
This group of symbols means Warning! Watch Out! possible  
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  
Consult symbols and related instructions below for necessary actions  
to avoid the hazards.  
Y
Marks a special safety message.  
. Means “Note”; not safety related.  
1-2. Arc Welding Hazards  
Y
The symbols shown below are used throughout this manual to  
call attention to and identify possible hazards. When you see  
the symbol, watch out, and follow the related instructions to  
avoid the hazard. The safety information given below is only  
a summary of the more complete safety information found in  
the Safety Standards listed in Section 1-4. Read and follow all  
Safety Standards.  
D
D
D
If earth grounding of the workpiece is required, ground it directly  
with a separate cable do not use work clamp or work cable.  
Do not touch electrode if you are in contact with the work, ground,  
or another electrode from a different machine.  
Use only well-maintained equipment. Repair or replace damaged  
parts at once. Maintain unit according to manual.  
D
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Y
Y
Only qualified persons should install, operate, maintain, and  
repair this unit.  
During operation, keep everybody, especially children, away.  
Clamp work cable with good metal-to-metal contact to workpiece  
or worktable as near the weld as practical.  
D
D
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
ELECTRIC SHOCK can kill.  
Do not connect more than one electrode or work cable to any  
single weld output terminal.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The electrode and work circuit is  
electrically live whenever the output is on. The input  
power circuit and machine internal circuits are also  
SIGNIFICANT DC VOLTAGE exists after removal of  
input power on inverters.  
live when power is on. In semiautomatic or automatic wire welding, the  
wire, wire reel, drive roll housing, and all metal parts touching the  
welding wire are electrically live. Incorrectly installed or improperly  
groundedequipment is a hazard.  
D
Turn Off inverter, disconnect input power, and discharge input  
capacitors according to instructions in Maintenance Section  
before touching any parts.  
D
D
D
Do not touch live electrical parts.  
Wear dry, hole-free insulating gloves and body protection.  
FUMES AND GASES can be hazardous.  
Insulate yourself from work and ground using dry insulating mats  
or covers big enough to prevent any physical contact with the work  
or ground.  
Welding produces fumes and gases. Breathing  
these fumes and gases can be hazardous to your  
health.  
D
Do not use AC output in damp areas, if movement is confined, or if  
there is a danger of falling.  
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
D
D
Use AC output ONLY if required for the welding process.  
If inside, ventilate the area and/or use exhaust at the arc to remove  
welding fumes and gases.  
If AC output is required, use remote output control if present on  
unit.  
D
D
If ventilation is poor, use an approved air-supplied respirator.  
D
Disconnect input power or stop engine before installing or  
servicing this equipment. Lockout/tagout input power according to  
OSHA 29 CFR 1910.147 (see Safety Standards).  
Read the Material Safety Data Sheets (MSDSs) and the  
manufacturers instructions for metals, consumables, coatings,  
cleaners, and degreasers.  
D
D
Properly install and ground this equipment according to its  
Owners Manual and national, state, and local codes.  
D
Work in a confined space only if it is well ventilated, or while  
wearing an air-supplied respirator. Always have a trained watch-  
person nearby. Welding fumes and gases can displace air and  
lower the oxygen level causing injury or death. Be sure the breath-  
ing air is safe.  
Always verify the supply ground check and be sure that input  
power cord ground wire is properly connected to ground terminal in  
disconnect box or that cord plug is connected to a properly  
groundedreceptacle outlet.  
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-  
erations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
D
D
When making input connections, attach proper grounding conduc-  
tor first double-check connections.  
Frequently inspect input power cord for damage or bare wiring –  
replace cord immediately if damaged bare wiring can kill.  
Do not weld on coated metals, such as galvanized, lead, or  
cadmiumplated steel, unless the coating is removed from the weld  
area, the area is well ventilated, and if necessary, while wearing an  
air-suppliedrespirator. The coatings and any metals containing  
these elements can give off toxic fumes if welded.  
D
D
D
Turn off all equipment when not in use.  
Do not use worn, damaged, undersized, or poorly spliced cables.  
Do not drape cables over your body.  
OM-1314 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ARC RAYS can burn eyes and skin.  
BUILDUP OF GAS can injure or kill.  
D
D
Shut off shielding gas supply when not in use.  
Arc rays from the welding process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin. Sparks fly off from the  
weld.  
Always ventilate confined spaces or use  
approved air-supplied respirator.  
D
Wear a welding helmet fitted with a proper shade of filter to protect  
your face and eyes when welding or watching (see ANSI Z49.1  
and Z87.1 listed in Safety Standards).  
HOT PARTS can cause severe burns.  
D
D
D
Wear approved safety glasses with side shields under your  
helmet.  
D
D
Do not touch hot parts bare handed.  
Use protective screens or barriers to protect others from flash and  
glare; warn others not to watch the arc.  
Allow cooling period before working on gun or  
torch.  
Wear protective clothing made from durable, flame-resistant mate-  
rial (leather and wool) and foot protection.  
MAGNETIC FIELDS can affect pacemakers.  
WELDING can cause fire or explosion.  
D
D
Pacemaker wearers keep away.  
Wearers should consult their doctor before  
going near arc welding, gouging, or spot  
welding operations.  
Welding on closed containers, such as tanks,  
drums, or pipes, can cause them to blow up. Sparks  
can fly off from the welding arc. The flying sparks, hot  
workpiece, and hot equipment can cause fires and  
burns. Accidental contact of electrode to metal objects can cause  
sparks, explosion, overheating, or fire. Check and be sure the area is  
safe before doing any welding.  
NOISE can damage hearing.  
D
D
D
Protect yourself and others from flying sparks and hot metal.  
Do not weld where flying sparks can strike flammable material.  
Noise from some processes or equipment can  
damagehearing.  
Remove all flammables within 35 ft (10.7 m) of the welding arc. If  
this is not possible, tightly cover them with approved covers.  
D
Wear approved ear protection if noise level is  
high.  
D
Be alert that welding sparks and hot materials from welding can  
easily go through small cracks and openings to adjacent areas.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
CYLINDERS can explode if damaged.  
Be aware that welding on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
Shielding gas cylinders contain gas under high  
pressure. If damaged, a cylinder can explode. Since  
gas cylinders are normally part of the welding  
process, be sure to treat them carefully.  
D
D
Do not weld on closed containers such as tanks, drums, or pipes,  
unless they are properly prepared according to AWS F4.1 (see  
Safety Standards).  
Connect work cable to the work as close to the welding area as  
practical to prevent welding current from traveling long, possibly  
unknown paths and causing electric shock and fire hazards.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, slag, open flames, sparks, and arcs.  
Install cylinders in an upright position by securing to a stationary  
support or cylinder rack to prevent falling or tipping.  
D
D
Do not use welder to thaw frozen pipes.  
Remove stick electrode from holder or cut off welding wire at  
contact tip when not in use.  
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.  
Never drape a welding torch over a gas cylinder.  
D
D
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
Never allow a welding electrode to touch any cylinder.  
Never weld on a pressurized cylinder explosion will result.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any welding.  
Use only correct shielding gas cylinders, regulators, hoses, and fit-  
tings designed for the specific application; maintain them and  
associated parts in good condition.  
FLYING METAL can injure eyes.  
D
D
Turn face away from valve outlet when opening cylinder valve.  
D
Welding, chipping, wire brushing, and grinding  
cause sparks and flying metal. As welds cool,  
they can throw off slag.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
D
Read and follow instructions on compressed gas cylinders,  
associated equipment, and CGA publication P-1 listed in Safety  
Standards.  
D
Wear approved safety glasses with side  
shields even under your welding helmet.  
OM-1314 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Additional Symbols For Installation, Operation, And Maintenance  
FIRE OR EXPLOSION hazard.  
MOVING PARTS can cause injury.  
D
Do not install or place unit on, over, or near  
combustiblesurfaces.  
D
D
Keep away from moving parts such as fans.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
D
Do not install unit near flammables.  
D
Do not overload building wiring be sure power supply system is  
properly sized, rated, and protected to handle this unit.  
FALLING UNIT can cause injury.  
H.F. RADIATION can cause interference.  
D
D
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, or any other accessories.  
D
High-frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
Use equipment of adequate capacity to lift and  
support unit.  
D
Have only qualified persons familiar with  
electronic equipment perform this installation.  
If using lift forks to move unit, be sure forks are  
long enough to extend beyond opposite side of  
unit.  
D
D
The user is responsible for having a qualified electrician prompt-  
ly correct any interference problem resulting from the installa-  
tion.  
If notified by the FCC about interference, stop using the  
equipmentat once.  
OVERUSE can cause OVERHEATING  
D
D
Allow cooling period; follow rated duty cycle.  
D
D
Have the installation regularly checked and maintained.  
Reduce current or reduce duty cycle before  
starting to weld again.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
D
Do not block or filter airflow to unit.  
STATIC (ESD) can damage PC boards.  
D
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
ARC WELDING can cause interference.  
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
MOVING PARTS can cause injury.  
D
Be sure all equipment in the welding area is  
electromagneticallycompatible.  
D
D
Keep away from moving parts.  
Keep away from pinch points such as drive  
rolls.  
D
D
D
D
To reduce possible interference, keep weld cables as short as  
possible, close together, and down low, such as on the floor.  
Locate welding operation 100 meters from any sensitive elec-  
tronic equipment.  
WELDING WIRE can cause injury.  
Be sure this welding machine is installed and grounded  
according to this manual.  
D
D
Do not press gun trigger until instructed to do  
so.  
If interference still occurs, the user must take extra measures  
such as moving the welding machine, using shielded cables,  
using line filters, or shielding the work area.  
Do not point gun toward any part of the body,  
other people, or any metal when threading  
welding wire.  
1-4. Principal Safety Standards  
Safety in Welding and Cutting, ANSI Standard Z49.1, from American  
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-  
dent of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
Canadian Standards Association, Standards Sales, 178 Rexdale  
Boulevard, Rexdale, Ontario, Canada M9W 1R3.  
Safe Practices For Occupation And Educational Eye And Face  
Protection, ANSI Standard Z87.1, from American National Standards  
Institute, 1430 Broadway, New York, NY 10018.  
Recommended Safe Practices for the Preparation for Weldingand Cut-  
ting of Containers That Have Held Hazardous Substances, American  
Welding Society Standard AWS F4.1, from American Welding Society,  
550 N.W. LeJeune Rd, Miami, FL 33126  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting And Welding Processes, NFPA Standard 51B, from National  
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
OM-1314 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-5. EMF Information  
Considerations About Welding And The Effects Of Low Frequency  
Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding current, as it flows through welding cables, will cause electro-  
magnetic fields. There has been and still is some concern about such  
fields. However, after examining more than 500 studies spanning 17  
years of research, a special blue ribbon committee of the National  
Research Council concluded that: The body of evidence, in the  
committees judgment, has not demonstrated that exposure to power-  
frequency electric and magnetic fields is a human-health hazard.”  
However, studies are still going forth and evidence continues to be  
examined.Until the final conclusions of the research are reached, you  
may wish to minimize your exposure to electromagnetic fields when  
welding or cutting.  
4. Keep welding power source and cables as far away from opera-  
tor as practical.  
5. Connect work clamp to workpiece as close to the weld as possi-  
ble.  
About Pacemakers:  
To reduce magnetic fields in the workplace, use the following  
procedures:  
Pacemaker wearers consult your doctor first. If cleared by your doctor,  
then following the above procedures is recommended.  
OM-1314 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 CONSIGNES DE SECURITE LIRE AVANT  
UTILISATION  
som _nd_fre 5/97  
1-1. Signification des symboles  
SignifieMise en garde ! Soyez vigilant ! Cette procédure  
présente des risques de danger ! Ceux-ci sont identifiés  
par des symboles adjacents aux directives.  
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des  
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN  
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles  
et aux directives ci-dessous afin de connaître les mesures à prendre pour  
éviter tout danger.  
Y
Identifie un message de sécurité particulier.  
. Signifie NOTA ; nest pas relatif à la sécurité.  
1-2. Dangers relatifs au soudage à larc  
Y
Les symboles présentés ci-après sont utilisés tout au long du  
présent manuel pour attirer votre attention et identifier les risques  
de danger. Lorsque vous voyez un symbole, soyez vigilant et  
suivez les directives mentionnées afin d’éviter tout danger. Les  
consignes de sécurité présentées ci-après ne font que résumer  
linformation contenue dans les normes de sécurité énumérées  
à la section 1-4. Veuillez lire et respecter toutes ces normes de  
sécurité.  
D
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la  
terre ou une électrode provenant dune autre machine.  
Nutiliser quun matériel en bon état. Réparer ou remplacer sur-le-  
champ les pièces endommagées. Entretenir lappareil conformément  
à ce manuel.  
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.  
Maintenir solidement en place tous les panneaux et capots.  
Y
Y
Linstallation, lutilisation, lentretien et les réparations ne doi-  
vent être confiés qu’à des personnes qualifiées.  
Fixer le câble de retour de façon à obtenir un bon contact métal-métal  
avec la pièce à souder ou la table de travail, le plus près possible de la  
soudure.  
Au cours de lutilisation, tenir toute personne à l’écart et plus par-  
ticulièrement les enfants.  
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact  
avec tout objet métallique.  
UN CHOC ÉLECTRIQUE peut tuer.  
Un simple contact avec des pièces électriques peut  
provoquer une électrocution ou des blessures graves.  
L’électrode et le circuit de soudage sont sous tension  
dès que lappareil est sur ON. Le circuit dentrée et les  
circuits internes de lappareil sont également sous  
Il y a DU COURANT CONTINU IMPORTANT dans les  
convertisseurs après la suppression de lalimenta-  
tion électrique.  
D
Arrêter les convertisseurs, débrancher le courant électrique, et dé-  
charger les condensateurs dalimentation selon les instructions  
indiquées dans la partie entretien avant de toucher les pièces.  
tension à ce moment-là. En soudage semi-automatique ou automatique,  
le fil, le dévidoir, le logement des galets dentraînement et les pièces  
métalliques en contact avec le fil de soudage sont sous tension. Des  
matériels mal installés ou mal mis à la terre présentent un danger.  
D
D
Ne jamais toucher les pièces électriques sous tension.  
Porter des gants et des vêtements de protection secs ne comportant  
pas de trous.  
LES FUMÉES ET LES GAZ peuvent  
D
Sisoler de la pièce et de la terre au moyen de tapis ou dautres  
moyens isolants suffisamment grands pour empêcher le contact phy-  
sique éventuel avec la pièce ou la terre.  
Ne pas se servir de source électrique àcourant électrique dans les zones  
humides, dans les endroits confinés ou là où on risque de tomber.  
être dangereux.  
Le soudage génère des fumées et des gaz. Leur  
D
D
D
D
inhalation peut être dangereux pour votre santé.  
D
Eloigner votre tête des fumées. Ne pas respirer  
Se servir dune source électrique àcourant électrique UNIQUEMENT si le  
procédé de soudage le demande.  
les fumées.  
D
A lintérieur, ventiler la zone et/ou utiliser un échappement au niveau  
de larc pour l’évacuation des fumées et des gaz de soudage.  
Si la ventilation est insuffisante, utiliser un respirateur à alimenta-  
tion dair homologué.  
Lire les spécifications de sécurité des matériaux (MSDSs) et les  
instructions du fabricant concernant les métaux, les consomma-  
bles, les revêtements, les nettoyants et les dégraisseurs.  
Travailler dans un espace fermé seulement sil est bien ventilé ou en  
portant un respirateur à alimentation dair. Demander toujours à un  
surveillant dûment formé de se tenir à proximité. Des fumées et des  
gaz de soudage peuvent déplacer lair et abaisser le niveau doxy-  
gène provoquant des blessures ou des accidents mortels. Sassu-  
rer que lair de respiration ne présente aucun danger.  
Si lutilisation dune source électrique àcourant électrique savère néces-  
saire, se servir de la fonction de télécommande si lappareil en est équipé.  
D
D
Couper lalimentation ou arrêter le moteur avant de procéder à linstal-  
lation, à la réparation ou à lentretien de lappareil. Déverrouiller  
lalimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de  
sécurité).  
Installer et mettre à la terre correctement cet appareil conformément à  
son manuel dutilisation et aux codes nationaux, provinciaux et  
municipaux.  
Toujours vérifier la terre du cordon dalimentation Vérifier et sassu-  
rer que le fil de terre du cordon dalimentation est bien raccordé à la  
borne de terre du sectionneur ou que la fiche du cordon est raccordée  
à une prise correctement mise à la terre.  
D
D
D
D
D
Ne pas souder dans des endroits situés à proximité dopérations de  
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les  
rayons de larc peuvent réagir en présence de vapeurs et former des  
gaz hautement toxiques et irritants.  
Ne pas souder des métaux munis dun revêtement, tels que lacier  
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-  
ment nait été enlevé dans la zone de soudure, que lendroit soit bien  
ventilé, et si nécessaire, en portant un respirateur à alimentation  
dair. Les revêtements et tous les métaux renfermant ces éléments  
peuvent dégager des fumées toxiques en cas de soudage.  
D
D
En effectuant les raccordements dentrée fixer dabord le conducteur  
de mise à la terre approprié et contre-vérifier les connexions.  
Vérifier fréquemment le cordon dalimentation pour voir sil nest pas  
endommagé ou dénudé – remplacer le cordon immédiatement sil est  
endommagé – un câble dénudé peut provoquer une électrocution.  
Mettre lappareil hors tension quand on ne lutilise pas.  
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-  
sante ou mal épissés.  
D
D
D
D
Ne pas enrouler les câbles autour du corps.  
Si la pièce soudée doit être mise à la terre, le faire directement avec un  
câble distinct ne pas utiliser le connecteur de pièce ou le câble de  
retour.  
OM-1314 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LES RAYONS DE LARC peuvent pro-  
voquer des brûlures dans les yeux et  
sur la peau.  
LES ACCUMULATIONS DE GAZ ris-  
quent de provoquer des blessures ou  
même la mort.  
Le rayonnement de larc du procédé de soudage  
génère des rayons visibles et invisibles intenses  
(ultraviolets et infrarouges) susceptibles de provoquer  
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées  
pendant le soudage.  
D
Fermer lalimentation du gaz protecteur en cas de  
non utilisation.  
D
Veiller toujours à bien aérer les espaces confinés ou se servir dun respi-  
rateur dadduction dair homologué.  
D
Porter un casque de soudage muni dun écran de filtre approprié pour  
protéger votre visage et vos yeux pendant le soudage ou pour regar-  
der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).  
DES PIÈCES CHAUDES peuvent pro-  
voquer des brûlures graves.  
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est  
trop élevé.  
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair  
et de l’éblouissement; demander aux autres personnes de ne pas re-  
garder larc.  
Porter des vêtements de protection constitué dans une matière dura-  
ble, résistant au feu (cuir ou laine) et une protection des pieds.  
D
D
Ne pas toucher des parties chaudes à mains nues  
Prévoir une période de refroidissement avant  
dutiliser le pistolet ou la torche.  
D
LE SOUDAGE peut provoquer un  
incendie ou une explosion.  
Le soudage effectué sur des conteneurs fermés tels  
que des réservoirs, tambours ou des conduites peut  
provoquer leur éclatement. Des étincelles peuvent être  
projetées de larc de soudure. La projection d’étincel-  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
D
D
Porteurs de stimulateur cardiaque, restez à distance.  
Les porteurs dun stimulateur cardiaque doivent  
dabord consulter leur médecin avant de sapprocher  
des opérations de soudage à larc, de gougeage ou  
de soudage par points.  
les, des pièces chaudes et des équipements chauds peut provoquer des  
incendies et des brûlures. Le contact accidentel de l’électrode avec des  
objets métalliques peut provoquer des étincelles, une explosion, un  
surchauffement ou un incendie. Avant de commencer le soudage, vérifier  
et sassurer que lendroit ne présente pas de danger.  
D
D
D
Se protéger et dautres personnes de la projection d’étincelles et de  
LE BRUIT peut affecter louïe.  
métal chaud.  
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur  
des substances inflammables.  
Le bruit des processus et des équipements peut affecter  
louïe.  
Déplacer toutes les substances inflammables à une distance de 10,7  
m de larc de soudage. En cas dimpossibilité les recouvrir soigneuse-  
ment avec des protections homologués.  
Des étincelles et des matériaux chauds du soudage peuvent facile-  
ment passer dans dautres zones en traversant de petites fissures et  
des ouvertures.  
D
Porter des protections approuvés pour les oreilles si  
le niveau sondre est trop élevé.  
D
D
D
D
Surveiller tout déclenchement dincendie et tenir un extincteur à proxi-  
Si des BOUTEILLES sont endomma-  
gées, elles pourront exploser.  
mité.  
Le soudage effectué sur un plafond, plancher, paroi ou séparation  
peut déclencher un incendie de lautre côté.  
Des bouteilles de gaz protecteur contiennent du gaz  
sous haute pression. Si une bouteille est endomma-  
gée, elle peut exploser. Du fait que les bouteilles de gaz  
font normalement partie du procédé de soudage, les  
Ne pas effectuer le soudage sur des conteneurs fermés tels que des  
réservoirs, tambours, ou conduites, à moins quils naient été prépa-  
rés correctement conformément à AWS F4.1 (voir les normes de  
sécurité).  
Brancher le câble sur la pièce le plus près possible de la zone de sou-  
dage pour éviter le transport du courant sur une longue distance par  
des chemins inconnus éventuels en provoquant des risques d’élec-  
trocution et dincendie.  
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-  
lées.  
En cas de non utilisation, enlever la baguette d’électrode du porte-  
électrode ou couper le fil à la pointe de contact.  
Porter des vêtements de protection dépourvus dhuile tels que des  
gants en cuir, une chemise en matériau lourd, des pantalons sans re-  
vers, des chaussures hautes et un couvre chef.  
Avant de souder, retirer toute substance combustible de vos poches  
telles quun allumeur au butane ou des allumettes.  
manipuler avec précaution.  
D
D
D
D
Protéger les bouteilles de gaz comprimé dune chaleur excessive,  
des chocs mécaniques, du laitier, des flammes ouvertes, des étin-  
celles et des arcs.  
Placer les bouteilles debout en les fixant dans un support stationnai-  
re ou dans un porte-bouteilles pour les empêcher de tomber ou de  
se renverser.  
Tenir les bouteilles éloignées des circuits de soudage ou autres cir-  
cuits électriques.  
Ne jamais placer une torche de soudage sur une bouteille à gaz.  
Une électrode de soudage ne doit jamais entrer en contact avec une  
D
D
D
D
D
bouteille.  
D
D
D
Ne jamais souder une bouteille pressurisée risque dexplosion.  
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,  
tuyaux et raccords convenables pour cette application spécifique;  
les maintenir ainsi que les éléments associés en bon état.  
DES PARTICULES VOLANTES  
peuvent blesser les yeux.  
D
D
D
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la  
bouteille.  
Maintenir le chapeau de protection sur la soupape, sauf en cas duti-  
lisation ou de branchement de la bouteille.  
Lire et suivre les instructions concernant les bouteilles de gaz com-  
primé, les équipements associés et les publications P-1 CGA énu-  
mérées dans les normes de sécurité.  
D
Le soudage, l’écaillement, le passage de la pièce  
à la brosse en fil de fer, et le meulage génèrent  
des étincelles et des particules métalliques vo-  
lantes. Pendant la période de refroidissement des soudures, elles ris-  
quent de projeter du laitier.  
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.  
OM-1314 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Dangers supplémentaires en relation avec linstallation, le fonctionnement  
et la maintenance  
Risque DINCENDIE OU  
DEXPLOSION.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Ne pas placer lappareil sur, au-dessus ou à proxi-  
mité de surfaces infllammables.  
D
D
Rester à l’écart des organes mobiles comme le  
ventilateur.  
Maintenir fermés et fixement en place les portes,  
panneaux, recouvrements et dispositifs de  
protection.  
D
D
Ne pas installer lappareil à proximité de produits inflammables  
Ne pas surcharger linstallation électrique sassurer que lalimen-  
tation est correctement dimensionné et protégé avant de mettre  
lappareil en service.  
LE RAYONNEMENT HAUTE FRÉ-  
QUENCE (H.F.) risque de provoquer  
des interférences.  
LA CHUTE DE LAPPAREIL peut  
blesser.  
D
Le rayonnement haute frequence peut provoquer  
des interférences avec les équipements de ra-  
dionavigationet de communication, les services  
de sécurité et les ordinateurs.  
D
D
Utiliser lanneau de levage uniquement pour sou-  
lever lappareil, NON PAS les chariot, les bouteil-  
les de gaz ou tout autre accessoire.  
D
Demander seulement à des personnes qualifiées familiarisées  
avec des équipements électroniques de faire fonctionner linstalla-  
tion.  
Lutilisateur est tenu de faire corriger rapidement par un électricien  
qualifié les interférences résultant de linstallation.  
Utiliser un engin dune capacité appropriée pour  
soulever lappareil.  
D
En utilisant des fourches de levage pour déplacer lunité, sassurer  
que les fourches sont suffisamment longues pour dépasser du côté  
opposé de lappareil.  
D
D
Si le FCC signale des interférences, arrêter immédiatement lappa-  
reil.  
LEMPLOI EXCESSIF peut  
SURCHAUFFER L’ÉQUIPEMENT.  
D
D
Effectuer régulièrement le contrôle et lentretien de linstallation.  
Maintenir soigneusement fermés les portes et les panneaux des  
sources de haute fréquence, maintenir les éclateurs à une distance  
correcte et utiliser une terre et et un blindage pour réduire les interfé-  
rences éventuelles.  
D
D
Prévoir une période de refroidissement, respec-  
ter le cycle opératoire nominal.  
Réduire le courant ou le cycle opératoire avant de  
recommancer le soudage.  
LE SOUDAGE À LARC risque de  
D
Ne pas obstruer les passages dair du poste.  
provoquer des interférences.  
LES CHARGES ÉLECTROSTATI-  
QUES peuvent endommager les cir-  
cuits imprimés.  
D
L’énergie électromagnétique risque de provoquer  
des interférences pour l’équipement électronique  
sensible tel que les ordinateurs et l’équipement  
commandé par ordinateur tel que les robots.  
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit com-  
D
D
Établir la connexion avec la barrette de terre  
patible électromagnétiquement.  
avant de manipuler des cartes ou des pièces.  
Pour réduire la possibilité dinterférence, maintenir les câbles de  
soudage aussi courts que possible, les grouper, et les poser aussi  
bas que possible (ex. par terre).  
Veiller à souder à une distance de 100 mètres de tout équipement  
électronique sensible.  
Veiller à ce que ce poste de soudage soit posé et mis à la terre  
conformément à ce mode demploi.  
En cas dinterférences après avoir pris les mesures précédentes, il  
incombe à lutilisateur de prendre des mesures supplémentaires tel-  
les que le déplacement du poste, lutilisation de câbles blindés, luti-  
lisation de filtres de ligne ou la pose de protecteurs dans la zone de  
travail.  
Utiliser des pochettes et des boîtes antistatiques  
pour stocker, déplacer ou expédier des cartes de  
circuits imprimes.  
D
D
D
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
D
Ne pas sapprocher des organes mobiles.  
Ne pas sapprocher des points de coincement  
tels que des rouleaux de commande.  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
LES FILS DE SOUDAGE peuvent pro-  
voquer des blessures.  
D
D
Porteurs de stimulateur cardiaque, restez à dis-  
D
D
Ne pas appuyer sur la gachette avant den avoir  
reçu linstruction.  
tance.  
Les porteurs dun stimulateur cardiaque doivent  
dabord consulter leur médecin avant de sappro-  
cher des opérations de soudage à larc, de gou-  
geage ou de soudage par points.  
Ne pas diriger le pistolet vers soi, dautres person-  
nes ou toute pièce mécanique en engageant le fil  
de soudage.  
OM-1314 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-4. Principales normes de sécurité  
Safety in Welding and Cutting, norme ANSI Z49.1, de lAmerican Wel-  
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de la Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent  
of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Règles de sécurité en soudage, coupage et procédés connexes, norme  
CSA W117.2, de lAssociation canadienne de normalisation, vente de  
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.  
RecommendedSafe Practice for the Preparation for Welding and Cut-  
ting of Containers That Have Held Hazardous Substances, norme AWS  
F4.1, de lAmerican Welding Society, 550 N.W. Lejeune Rd, Miami FL  
33126  
Safe Practices For Occupation And Educational Eye And Face Protec-  
tion, norme ANSI Z87.1, de lAmerican National Standards Institute,  
1430 Broadway, New York, NY 10018.  
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting and Welding Processes, norme NFPA 51B, de la National Fire  
Protection Association, Batterymarch Park, Quincy, MA 02269.  
1-5. Information sur les champs électromagnétiques  
Données sur le soudage électrique et sur les effets, pour lorganisme,  
des champs magnétiques basse fréquence  
Afin de réduire les champs électromagnétiques dans lenvironnement  
de travail, respecter les consignes suivantes :  
1
Garder les câbles ensembles en les torsadant ou en les  
attachant avec du ruban adhésif.  
Le courant de soudage, pendant son passage dans les câbles de sou-  
dage, causera des champs électromagnétiques. Il y a eu et il y a encore  
un certain souci à propos de tels champs. Cependant, après avoir ex-  
aminé plus de 500 études qui ont été faites pendant une période de  
recherche de 17 ans, un comité spécial ruban bleu du National Re-  
search Council a conclu: Laccumulation de preuves, suivant le  
jugement du comité, na pas démontré que lexposition aux champs  
magnétiqueset champs électriques à haute fréquence représente un  
risque à la santé humaine. Toutefois, des études sont toujours en cours  
et les preuves continuent à être examinées. En attendant que les con-  
clusions finales de la recherche soient établies, il vous serait  
souhaitablede réduire votre exposition aux champs électromagnéti-  
ques pendant le soudage ou le coupage.  
2
3
Mettre tous les câbles du côté opposé de lopérateur.  
Ne pas courber pas et ne pas entourer pas les câbles autour de  
votre corps.  
4
5
Garder le poste de soudage et les câbles le plus loin possible de  
vous.  
Relier la pince de masse le plus près possible de la zone de  
soudure.  
Consignes relatives aux stimulateurs cardiaques :  
Les personnes qui portent un stimulateur cardiaque doivent avant tout  
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est  
alors recommandé de respecter les consignes cidessus.  
OM-1314 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2 INSTALLATION  
2-1. Specifications  
Amperes Input at  
Maximum  
Open-Circuit  
Voltage DC  
Rated Welding  
Amperage  
Range  
Rated Load Out-  
put 230 V, 60 Hz,  
Single-Phase  
Overall  
Dimensions  
KVA  
KW  
Weight  
Output  
Length: 17 in  
(432 mm)  
130 A @ 20.5 Volts  
DC, 30% Duty Cycle  
Width: 10 in  
(254 mm)  
20.5  
(0.27)*  
4.7  
(.05)*  
4
95 lb  
(43.1 kg)  
40 170  
33  
(.04)*  
Height: 15-1/2 in  
(394 mm)  
Solid/  
Stainless  
Flux Cored/  
Aluminum  
Calculated Wire  
Speed Range At  
No Load  
Max Wire Feed Speed While Welding  
Wire Type  
And Dia  
.023 .035 in  
.030 .045 in  
126 722 IPM  
500 IPM  
(0.6 0.9 mm)  
(0.8 1.1 mm)  
(3.2 18.3 m/min)  
(12.7 m/min)  
* While idling  
2-2. Volt-Ampere Curves  
Volt-ampere curves show mini-  
mum and maximum voltage and  
amperage output capabilities of  
unit. Curves of other settings fall be-  
tween curves shown.  
va_curve1 4/95 SB-180 765  
OM-1314 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-3. Duty Cycle And Overheating  
Duty Cycle is percentage of 10 min-  
utes that unit can weld at rated load  
without overheating.  
300  
250  
If unit overheats, thermostat(s)  
opens, output stops, and cooling  
fan runs. Wait fifteen minutes for  
unit to cool. Reduce amperage or  
duty cycle before welding.  
200  
150  
Y
Exceeding duty cycle can  
damage unit or gun and void  
warranty.  
100  
75  
50  
10  
15 20 25 30  
40 50 60 70 80 100  
% DUTY CYCLE  
30% Duty Cycle At 130 Amperes  
3 Minutes Welding  
7 Minutes Resting  
Overheating  
A or V  
0
15  
OR  
Reduce Duty Cycle  
Minutes  
duty1 4/95 SB-180 844  
OM-1314 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-4. Installing Work Clamp  
1
2
3
4
Insulator  
1
Bolt  
Smaller Hole  
Work Clamp Tabs  
Bend tabs around work cable.  
5
6
Work Cable From Unit  
Nut  
6
2
5
Tools Needed:  
3/8, 7/16 in  
3
4
Ref. ST-025 190-D  
2-5. Installing Gas Supply  
Obtain gas cylinder and chain to  
running gear, wall, or other station-  
ary support so cylinder cannot fall  
and break off valve.  
1
2
1
2
Cap  
Cylinder Valve  
Remove cap, stand to side of valve,  
and open valve slightly. Gas flow  
blows dust and dirt from valve.  
Close valve.  
3
4
Cylinder  
Regulator/Flowmeter  
Install so face is vertical.  
Gas Hose Connection  
3
5
Fitting has 5/8-18 right-hand  
threads. Install gas hose.  
6
Flow Adjust  
Typical flow rate is 20 cfh (cubic feet  
per hour). Check wire manufactur-  
ers recommended flow rate.  
Argon Gas  
7
8
CO Adapter  
2
O-Ring  
Install adapter with O-ring between  
regulator/flowmeter and  
cylinder.  
CO  
2
OR  
6
5
1
2
4
3
7
8
Tools Needed:  
5/8, 1-1/8 in  
CO Gas  
2
ssb3.1* 12/92 ST-158 697-A  
OM-1314 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-6. Installing Welding Gun And Setting Gun Polarity For Wire Type  
1
2
3
4
5
Gun Opening  
Gun Trigger Receptacle  
Gun Securing Nut  
Drive Assembly  
Gun End  
Loosen securing nut. Insert gun  
end through opening until it bottoms  
against drive assembly. Tighten  
nut.  
6
Gun Trigger Plug  
Insert plug into receptacle, and  
tighten threaded collar.  
Close door.  
. Follow wire manufacturers recommendation.  
Solid Steel Or  
Aluminum Wires  
(GMAWWith Gas)  
Flux Cored Wires  
(FCAWWithout Gas)  
Straight Polarity  
DCEN  
Reverse Polarity  
DCEP  
1
2
Front Panel Openings  
3
4
6
5
Tools Needed:  
5/16 in  
ST-149 328-B / Ref. ST-159 270  
OM-1314 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-7. Electrical Service Guide  
230  
20.5  
25  
Input Voltage  
Input Amperes At Rated Output  
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes  
Min Input Conductor Size In AWG/Kcmil  
Max Recommended Input Conductor Length In Feet (Meters)  
Min Grounding Conductor Size In AWG/Kcmil  
Reference: 1996 National Electrical Code (NEC)  
14  
64 (19)  
14  
S-0092-J  
2-8. Selecting A Location And Connecting Input Power  
1
Rating Label  
Supply correct input power.  
2
3
Plug  
Receptacle  
Connect plug to receptacle.  
Line Disconnect Device  
See Section 2-7.  
Special installation may be  
4
18 in (457 mm) of  
space for airflow  
4
Y
required where gasoline or  
volatile liquids are present –  
see NEC Article 511 or CEC  
Section 20.  
L1  
L2  
Y
Always connect  
grounding  
conductor first.  
= GND/PE  
3
L1  
L2  
1
2
230 VAC, 1  
Y
Do not move or operate unit  
where it could tip.  
ssb2.2* 1/94 ST-801 504  
OM-1314 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-9. Installing Wire Spool And Adjusting Hub Tension  
1 Lb Wire Spool  
Standard Wire Spool  
Standard Wire Reel  
Part No. 183 312  
Part No. 135 615  
When a slight force is needed  
to turn spool, tension is set.  
Tools Needed:  
15/16 in  
S-0499  
OM-1314 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-10. Installing Drive Roll And Threading Welding Wire  
Install drive roll onto shaft with de-  
sired groove in, and one set screw  
facing flat side of shaft. Tighten both  
set screws.  
1
Install drive roll.  
For Flux Cored Wire  
For Solid Wire  
3
Pull and hold wire; cut off end.  
2
Open pressure assembly.  
6 in  
(150 mm)  
4
Push wire thru guides into gun;  
continue to hold wire.  
5
Close and tighten pressure assembly,  
and let go of wire.  
6
Remove gun nozzle and contact tip.  
8
Press gun trigger until wire comes out  
of gun.  
7
Turn power On.  
9
Reinstall contact tip and nozzle.  
10 Feed wire to check drive roll  
pressure. Tighten knob enough to  
prevent slipping. Cut off wire; leave  
1/41/2 in (613 mm). Close and  
latch door.  
Tools Needed:  
WOOD  
Ref. ST-149 266-B / Ref. ST-149 326-B / Ref. 150 093-A / Ref. 180 968 / S-0627-A  
OM-1314 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-11. Weld Parameters  
Material Thickness  
Wire Type,  
Shielding Gas,  
And Flow Rate  
Wire  
Diameter  
(inch)  
Operator  
Controls  
1/4 in.  
3/16 in.  
1/8 in.  
14 ga.  
16 ga.  
18 ga.  
20 ga.  
22 ga.  
(6.4 mm) (4.8 mm) (3.2 mm)  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
Voltage Tap  
Wire Speed  
– –  
– –  
6
5
70  
5
4
60  
4
3
50  
3
3
30  
3
2
20  
2
2
5
1
.023  
.030  
.035  
.023  
.030  
.035  
.030  
.035  
.023  
.030  
0
E70S-6  
1
– –  
– –  
– –  
– –  
1
CO  
2
60  
6
45  
5
40  
4
35  
3
30  
2
25  
2
20  
2
20 cfh+  
30  
6
20  
5
20  
4
20  
3
20  
3
15  
2
5
2
100  
6
90  
5
75  
4
60  
3
50  
3
35  
2
20  
1
10  
1
E70S-6  
75% Argon  
25% CO  
20 cfh+  
2
70  
6
60  
5
50  
5
40  
4
30  
3
20  
2
10  
2
0
– –  
– –  
– –  
– –  
– –  
– –  
3
50  
6
45  
6
40  
5
30  
4
25  
3
25  
2
10  
2
50  
6
45  
6
30  
5
20  
4
20  
3
10  
– –  
– –  
3
10  
– –  
– –  
3
E71T-GS  
Flux Core  
40  
– –  
– –  
– –  
– –  
40  
5
30  
4
20  
4
20  
3
ER 308  
Stainless Steel  
Tri-Mix  
100  
6
90  
5
75  
4
60  
3
50  
3
40  
– –  
– –  
25  
– –  
– –  
20 cfh+  
75  
70  
60  
50  
40  
*Do not change Voltage switch position while welding. Wire Speed value in Table is a starting value only, and Wire Speed control setting can be fine  
tuned during welding.  
S-181 186  
SECTION 3 OPERATION  
3-1. Controls  
1
Wire Speed Control  
Use control to select a wire feed  
speed. As Voltage switch setting in-  
creases, wire speed range also in-  
creases.  
1
2
2
Voltage Switch  
The higher the selected number,  
the thicker the material that can be  
welded. Do not switch while  
welding.  
3
Power Switch  
3
Ref. ST-182 986-B  
OM-1314 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4 MAINTENANCE & TROUBLESHOOTING  
4-1. Maintenance  
. Maintain more often  
Y
Disconnectpower  
before maintaining.  
during severe conditions.  
3 Months  
Repair Or  
Clean And  
Tighten  
Weld  
Replace  
Cracked  
Cables  
Replace  
Damaged Or  
Unreadable  
Labels  
Connections  
And Cords  
6 Months  
Blow Out Or  
Vacuum Inside  
stat_maint 2/96  
4-2. Fuse F1  
Y
Turn Off unit, disconnect in-  
put power. Unlatch door and  
remove wrapper.  
1
1
2
Circuit Board PC1  
Fuse F1 (See Parts List For  
Rating)  
If F1 opens, wire drive motor shuts  
down. Replace F1 if open.  
2
Reinstall wrapper, and latch door.  
Tools Needed:  
3/8 in  
Ref. ST-801 552  
4-3. Short Circuit Shutdown  
If contact tip is shorted and sticks to workpiece, the unit shuts down, but fan runs. To resume operation, release gun  
trigger, turn Off unit, and remove contact tip from workpiece. Check contact tip and replace if damaged. Turn On unit to  
continue operation.  
OM-1314 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-4. Replacing Gun Contact Tip  
Y
Turn Off power before  
replacing contact tip.  
1
2
Nozzle  
Contact Tip  
Cut off welding wire at contact tip.  
Remove nozzle.  
Remove contact tip and install new  
contact tip. Reinstall nozzle.  
2
1
Tools Needed:  
ST-149 326-B  
4-5. Unicable Repair  
To repair or replace unicable, order Unicable Clamp Kit, part number 172 017. Kit includes all required instructions,  
clamps, inner support tube, compression clip, switch leads, and connectors.  
OM-1314 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-6. Cleaning Or Replacing Gun Liner  
Tools Needed:  
Y
Disconnect gun from unit.  
3/8 in  
Head Tube  
Remove nozzle, contact tip,  
adapter, and wire outlet guide.  
3/8 in  
Wire Outlet Guide  
Remove liner.  
Lay gun cable out straight  
before installing new liner.  
To Reassemble Gun:  
Insert new liner.  
Install and tighten wire outlet guide.  
Cut liner off 3/4 in (20 mm) (3/8 in  
[9.5 mm] for aluminum) from head  
tube.  
Blow out gun casing.  
Install adapter, contact tip, and  
nozzle.  
Ref. ST-800 797-A  
OM-1314 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-7. Replacing Switch And/Or Head Tube  
Y
Disconnect gun from unit.  
3
Slide handle.  
2
Remove switch housing. Note: If installing new  
switch, push switch lead connectors onto terminal of  
new switch (polarity is not important). Install switch  
back into handle, and secure with handle locking nut.  
If replacing head tube, continue to end of figure.  
1
Remove handle  
locking nut.  
4
Secure head  
tube in vice.  
5
Remove shock washers  
from front and rear of  
head tube.  
6
Loosen jam nut. Remove  
from vice and turn head  
tube out by hand.  
Do not disturb cable connection between  
cable connector and connector nut.  
7
Install both existing shock washers  
to new head tube and hand-tighten  
head tube into connector cable.  
8
Place head tube in vice and tighten  
to within 1/8 in (3.2 mm) spacing be-  
tween connector cable and body.  
9
Remove from vice. Reposition  
handle and install switch housing.  
Secure with handle locking nut.  
Tools Needed:  
3/4 in  
Ref. ST-800 795-A  
OM-1314 Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-8. Cleaning Or Repairing Drive Assembly  
Y
Turn Off power before  
cleaning or repairing drive  
assembly.  
1
2
Wire Spool  
Nozzle  
Cut welding wire off at nozzle.  
Retract wire onto spool and secure.  
3
4
5
6
7
Pressure Roll Arm  
Cotter Pin  
Pin  
Screw  
Bearing  
Remove bearing. Install new bear-  
ing and secure with screw. Reinstall  
arm onto pin and secure with cotter  
pin.  
8
9
Setscrew  
Drive Roll  
Remove drive roll.  
1
Push drive roll onto shaft with  
desired groove in. Turn drive roll so  
one setscrew faces flat side of  
shaft, and tighten both setscrews.  
10 Wire Inlet Guide  
2
Remove guide by pressing on  
barbed area or cutting off one end  
near housing and pulling it out of  
hole. Push new guide into hole from  
rear until it snaps in place.  
Close door.  
3
5
6
7
8
4
9
10  
8
Tools Needed:  
5/64 in  
Ref. ST-150 093-A / ST-149 266-B  
OM-1314 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-9. Troubleshooting  
Welding Trouble  
Remedy  
Secure power cord plug in receptacle (see Section 2-8).  
Check and replace power switch if necessary.  
No weld output; wire does not feed.  
Check fuse F1, and replace if necessary (see Section 4-2).  
Replace building line fuse or reset circuit breaker if open (see Section 2-8).  
Secure gun trigger plug in receptacle or repair leads, or replace trigger switch (see Section 2-6 and/or  
4-7).  
ThermostatTP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled  
(see Section 2-3).  
No weld output; wire feeds.  
Connect work clamp to get good metal to metal contact.  
Replace contact tip (see Section 4-4).  
Low weld output.  
Connect unit to proper input voltage or check for low line voltage (see Section 2-8).  
Readjust front panel settings (see Section 3-1).  
Low, high, or erratic wire speed.  
Change to correct groove in drive roll (see Section 2-10).  
Readjust drive roll pressure (see Section 2-10).  
Replace inlet guide, contact tip, and/or liner if necessary (see Sections 4-8, 4-4 and/or 4-6).  
Wire Drive/Gun Trouble  
Remedy  
Straightengun cable and/or replace damaged parts (see Section 4-6).  
Adjust drive roll pressure (see Section 2-10).  
Electrode wire feeding stops during  
welding.  
Readjust hub tension (see Section 2-9).  
Replace contact tip if blocked (see Section 4-4).  
Clean or replace wire inlet guide or liner if dirty or plugged (see Section 4-8, and Section 4-6).  
Replace drive roll if worn or slipping (see Section 2-10).  
Secure gun trigger plug in receptacle or repair leads, or replace trigger switch (see Section 2-6 and/or  
4-7).  
Check and clear any restrictions at drive assembly and liner (see Section 4-8, and Section 4-6).  
Have nearest Factory Authorized Service Agent check drive motor.  
Check relay CR1, and replace if necessary.  
OM-1314 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5 ELECTRICAL DIAGRAM  
SB-180 784-B  
Figure 5-1. Circuit Diagram  
OM-1314 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6 MIG WELDING (GMAW) GUIDELINES  
6-1. Typical MIG Process Connections  
Y
Weld current can damage  
electronic parts in vehicles.  
Disconnect both battery  
cables before welding on a  
vehicle. Place work clamp as  
close to the weld as possible.  
Regulator/  
Flowmeter  
Wire Feeder/  
Power Source  
Gun  
Shielding Gas  
Gas  
Workpiece  
Work Clamp  
light mig 5/967 / ST-801 909  
OM-1314 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-2. Typical MIG Process Control Settings  
These settings are guidelines only. Material and wire type, joint design, fitup,  
position, shielding gas, etc. affect settings. Test welds to be sure they comply to  
specifications.  
NOTE  
Material thickness determines weld  
parameters.  
1/8 or  
.125 in  
Convert Material  
Thickness to  
Amperage (A)  
(.001 in = 1 ampere)  
.125 in = 125 A  
Wire Size  
Amperage Range  
.035 in  
.023 in  
.030 in  
.035 in  
30 90 A  
40 145 A  
50 180 A  
Select Wire Size  
Select Wire Speed  
(Amperage)  
Wire  
Size  
Wire Speed  
(Approx.)  
Recommendation  
.023 in  
.030 in  
.035 in  
3.5 in per ampere  
2 in per ampere  
1.6 in per ampere  
3.5 x 125 A = 437 ipm  
2 x 125 A = 250 ipm  
1.6 x 125 A = 200 ipm  
125 A based on 1/8 in  
material thickness  
ipm = inch per minute  
Low voltage: wire stubs into work  
High voltage: arc is unstable (spatter)  
Select Voltage  
Set voltage midway between high/low voltage.  
Wire speed (amperage) controls weld pe-  
netration(wire speed = burn-off rate)  
Voltage controls height and width of  
weld bead.  
Ref. ST-801 865  
OM-1314 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-3. Holding And Positioning Welding Gun  
Welding wire is energized when gun trigger is pressed. Before lowering helmet and  
pressing trigger, be sure wire is no more than 1/2 in (13 mm) past end of nozzle,  
and tip of wire is positioned correctly on seam.  
NOTE  
1
Hold Gun and Control Gun  
Trigger  
1
2
3
4
Workpiece  
Work Clamp  
3
Electrode Extension (Stickout)  
1/4 to 1/2 in (6 To 13 mm)  
2
5
Cradle Gun and Rest Hand on  
Workpiece  
5
4
0°-15°  
90°  
90°  
End View Of Work Angle  
Side View Of Gun Angle  
GROOVE WELDS  
0°-15°  
45°  
45°  
End View Of Work Angle  
Side View Of Gun Angle  
FILLET WELDS  
S-0421-A  
OM-1314 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-4. Conditions That Affect Weld Bead Shape  
Weld bead shape depends on gun angle, direction of travel, electrode extension  
(stickout), travel speed, thickness of base metal, wire feed speed (weld current),  
and voltage.  
NOTE  
10°  
Push  
10°  
Perpendicular  
Drag  
GUN ANGLES AND WELD BEAD PROFILES  
Short  
Normal  
Long  
ELECTRODE EXTENSIONS (STICKOUT)  
Short  
Normal  
Long  
FILLET WELD ELECTRODE EXTENSIONS (STICKOUT)  
Slow  
Normal  
Fast  
GUN TRAVEL SPEED  
S-0634  
OM-1314 Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-5. Gun Movement During Welding  
Normally, a single stringer bead is satisfactory for most narrow groove weld joints;  
however, for wide groove weld joints or bridging across gaps, a weave bead or  
multiple stringer beads works better.  
NOTE  
1
2
3
Stringer Bead Steady  
Movement Along Seam  
1
2
Weave Bead Side To Side  
Movement Along Seam  
Weave Patterns  
Use weave patterns to cover a wide  
area in one pass of the electrode.  
3
S-0054-A  
6-6. Poor Weld Bead Characteristics  
1
2
3
4
5
Large Spatter Deposits  
Rough, Uneven Bead  
1
Slight Crater During Welding  
Bad Overlap  
Poor Penetration  
2
4
3
5
S-0053-A  
6-7. Good Weld Bead Characteristics  
1
2
3
Fine Spatter  
Uniform Bead  
Moderate Crater During  
Welding  
1
Weld a new bead or layer for each  
1/8 in (3.2 mm) thickness in metals  
being welded.  
4
5
No Overlap  
Good Penetration into Base  
Metal  
2
4
3
5
S-0052-B  
OM-1314 Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-8. Troubleshooting Excessive Spatter  
Excessive Spatter scattering of molten metal particles that  
cool to solid form near weld bead.  
S-0636  
Possible Causes  
Wire feed speed too high.  
Corrective Actions  
Select lower wire feed speed.  
Select lower voltage range.  
Use shorter electrode extension (stickout).  
Voltage too high.  
Electrode extension (stickout) too long.  
Workpiece dirty.  
Remove all grease, oil, moisture, rust, paint, undercoating, and dirt from work surface before welding.  
Increase flow of shielding gas at regulator/flowmeter and/or prevent drafts near welding arc.  
Use clean, dry welding wire.  
Insufficient shielding gas at welding arc.  
Dirty welding wire.  
Eliminate pickup of oil or lubricant on welding wire from feeder or liner.  
6-9. Troubleshooting Porosity  
Porosity small cavities or holes resulting from gas pockets  
in weld metal.  
S-0635  
Possible Causes  
Corrective Actions  
Insufficient shielding gas at welding arc.  
Increase flow of shielding gas at regulator/flowmeter and/or prevent drafts near welding arc.  
Remove spatter from gun nozzle.  
Check gas hoses for leaks.  
Place nozzle 1/4 to 1/2 in (6-13 mm) from workpiece.  
Hold gun near bead at end of weld until molten metal solidifies.  
Use welding grade shielding gas; change to different gas.  
Use clean, dry welding wire.  
Wrong gas.  
Dirty welding wire.  
Eliminate pick up of oil or lubricant on welding wire from feeder or liner.  
Workpiece dirty.  
Remove all grease, oil, moisture, rust, paint, coatings, and dirt from work surface before welding.  
Use a more highly deoxidizing welding wire (contact supplier).  
Welding wire extends too far out of nozzle. Be sure welding wire extends not more than 1/2 in (13 mm) beyond nozzle.  
6-10. Troubleshooting Excessive Penetration  
Excessive Penetration weld metal melting through base metal  
and hanging underneath weld.  
Excessive Penetration Good Penetration  
S-0639  
Possible Causes  
Excessive heat input.  
Corrective Actions  
Select lower voltage range and reduce wire feed speed.  
Increase travel speed.  
OM-1314 Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-11. Troubleshooting Lack Of Penetration  
Lack Of Penetration shallow  
fusion between weld metal and  
base metal.  
Lack of Penetration Good Penetration  
S-0638  
Possible Causes  
Corrective Actions  
Improper joint preparation.  
Improper weld technique.  
Material too thick. Joint preparation and design must provide access to bottom of groove while  
maintaining proper welding wire extension and arc characteristics.  
Maintain normal gun angle of 0 to 15 degrees to achieve maximum penetration.  
Keep arc on leading edge of weld puddle.  
Be sure welding wire extends not more than 1/2 in (13 mm) beyond nozzle.  
Select higher wire feed speed and/or select higher voltage range.  
Reduce travel speed.  
Insufficient heat input.  
6-12. Troubleshooting Incomplete Fusion  
Incomplete Fusion failure of weld metal to fuse completely with  
base metal or a preceeding weld bead.  
S-0637  
Possible Causes  
Workpiece dirty.  
Corrective Actions  
Remove all grease, oil, moisture, rust, paint, undercoating, and dirt from work surface before  
welding.  
Insufficient heat input.  
Select higher voltage range and/or adjust wire feed speed.  
Place stringer bead in proper location(s) at joint during welding.  
Adjust work angle or widen groove to access bottom during welding.  
Momentarily hold arc on groove side walls when using weaving technique.  
Keep arc on leading edge of weld puddle.  
Improper welding technique.  
Use correct gun angle of 0 to 15 degrees.  
6-13. Troubleshooting Burn-Through  
Burn-Throughweld metal melting completely through base metal  
resulting in holes where no metal remains.  
S-0640  
Possible Causes  
Corrective Actions  
Excessive heat input.  
Select lower voltage range and reduce wire feed speed.  
Increase and/or maintain steady travel speed.  
OM-1314 Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-14. Troubleshooting Waviness Of Bead  
Waviness Of Bead weld metal that is not parallel and does not cover  
joint formed by base metal.  
S-0641  
Possible Causes  
Welding wire extends too far out of nozzle. Be sure welding wire extends not more than 1/2 in (13 mm) beyond nozzle.  
Unsteady hand. Support hand on solid surface or use two hands.  
Corrective Actions  
6-15. Troubleshooting Distortion  
Distortion contraction of weld metal during welding that forces  
base metal to move.  
Base metal moves  
in the direction of  
the weld bead.  
S-0642  
Possible Causes  
Corrective Actions  
Excessive heat input.  
Use restraint (clamp) to hold base metal in position.  
Make tack welds along joint before starting welding operation.  
Select lower voltage range and/or reduce wire feed speed.  
Increase travel speed.  
Weld in small segments and allow cooling between welds.  
OM-1314 Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6-16. Common MIG Shielding Gases  
This is a general chart for common gases and where they are used. Many different combinations (mixtures) of  
shielding gases have been developed over the years. The most commonly used shielding gases are listed in the  
following table.  
Application  
Gas  
Short Circuiting  
Stainless Steel  
Short Circuiting  
Aluminum  
Spray Arc Steel  
Short Circuiting Steel  
Argon  
All Positions  
1
2
Argon + 25% CO  
Flat & Horizontal Fillet  
All Positions  
All Positions  
All Positions  
2
1
CO  
Flat & Horizontal Fillet  
2
3
Tri-Mix  
All Positions  
1
2
3
Globular Transfer  
Single Pass Welding Only  
90% HE + 7-1/2% AR + 2-1/2% CO  
2
OM-1314 Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-1314 Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 PARTS LIST  
. Hardware is common and  
not available unless listed.  
ST-801 633  
Figure 7-1. Main Assembly  
OM-1314 Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Figure 7-1. Main Assembly  
Quantity  
. . . 1 . . . . . . . . . . . . . . 131 315 . . DRIVE ASSEMBLY, wire (Fig 7-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . . 010 909 . . NUT, 375-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . . 010 910 . . WASHER, flat .406 ID x 0.81 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 4 . . . . . . . . . . . . . . 073 355 . . SPRING, cprsn .625 OD x 0.93 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . . . 111 998 . . PIN, cotter hair .120dia x 2.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . . . 111 929 . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . . 147 562 . . BAFFLE, center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . FM . . . . 117 014 . . MOTOR, fan 230V 50/60 Hz 2600RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . . 005 656 . . BLADE, fan 6.000 4wg 30 deg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . CR2 . . . 108 358 . . CONTACTOR, def prp 25A 2P 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . SR2 . . . 180 791 . . RECTIFIER, si 1PH 140A 200PIV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . . . . . . . . . . 147 461 . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . . R1 . . . . 000 101 . . RHEOSTAT, WW 50W 16 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . S2 . . . . 180 777 . . SWITCH, rotary 6 pin 1P 600V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . RC3 . . . 048 282 . . RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . . . . . . . . . . 147 560 . . PANEL, side lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . . . T1 . . . . 180 786 . . TRANSFORMER, power main . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . . PC1 . . . 172 543 . . CIRCUIT CARD, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . F1 . . . . 073 426 . . . . FUSE, mintr slo-blo 5A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . CR2 . . . 080 388 . . . . RELAY, encl 24VAC 3PDT 10A/120VAC . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 173 299 . . CLIP, hold-down relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . . 134 201 . . STAND-OFF, support PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 22 . . . . . . . . . . . . . . 147 563 . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . . 089 899 . . LATCH, slide flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . . . . . . . . . . 134 327 . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . . . . . . . . . . . 126 415 . . CLAMP, saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 26 . . . . . . . . . . . . . . 126 416 . . HANDLE, molded plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 27 . . . . . . . . . . . . . . . 111 443 . . BUSHING, strain relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 28 . . . . PLG1 . . . 152 118 . . CORD SET, 250V 6-50P 12GA 3/c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 29 . . . . . . . . . . . . . . 605 227 . . NUT, 750-14 knurled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 30 . . . . . . . . . . . . . . 147 462 . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 31 . . . . . GS1 . . . 128 751 . . VALVE, 230VAC 2 way . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 32 . . . . . R2,3 . . . 181 649 . . RESISTOR, WW fxd 40W 25 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 33 . . . . . VR1 . . . 090 288 . . VARISTOR w/TERMINALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 34 . . . . . . C1 . . . . 162 245 . . CAPACITOR, elctlt 140000uf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 35 . . . . . . . . . . . . . . 022 160 . . CLAMP, capacitor 3.000dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 36 . . . . . . Z1 . . . . 180 793 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 37 . . . . . . . . . . . . . . 147 566 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 38 . . . . . . . . . . . . . . 147 548 . . NUT, speed push-on type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
. . . 39 . . . . . . . . . . . . . . 146 753 . . BEZEL, front/rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 40 . . . . . . . . . . . . . . 010 368 . . CLAMP, work 200A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 41 . . . . . . . . . . . . . . 026 843 . . INSULATOR, vinyl blk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 42 . . . . . . . . . . . . . . 600 325 . . CABLE, weld cop strd No. 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16ft  
. . . 43 . . . . . . . . . . . . . . 169 903 . . M-15 GUN, (Fig 7-2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 44 . . . . . . . . . . . . . . . 111 644 . . BUSHING, strain relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 45 . . . . . . S1 . . . . 116 830 . . SWITCH, rocker DPST 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 46 . . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . . . . 1  
. . . 47 . . . . . . . . . . . . . . . . . . . . . . . . . KNOB, pointer (included w/Item 14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 48 . . . . . . . . . . . . . . 097 922 . . KNOB, pointer .875dia x .250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 49 . . . . . TE1 . . . . 122 385 . . TERMINAL ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 50 . . . . . . . . . . . . . . 174 504 . . . . LINK, jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . 113 149 . . CONNECTOR, rect 156 14skt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 110 160 . . CONNECTOR, rect 156 6skt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 000 067 . . TIP, contact scr .030 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 000 068 . . TIP, contact scr .035 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 087 299 . . TIP, contact scr .023 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 166 575 . . WRENCH, hex .078 across . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 135 615 . . BUSHING, nylon .390 ID x .750 OD x .750 lg . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . 183 312 . . ADAPTER RING, wire spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1314 Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
. Hardware is common and  
not available unless listed.  
1
2
3
4
5
6
7
6
8
9
10  
11  
13  
14  
15  
25  
27  
26  
12*  
20  
23  
22  
24  
16  
18  
21  
28  
17  
17  
19  
8
9
10  
11  
16  
18  
*Includes Item 17  
19  
ST-801 140  
Figure 7-2. M-15 Gun  
OM-1314 Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Part  
No.  
Description  
Quantity  
169 589  
Figure 7-2. M-15 Gun (Fig 7-1 Item 43)  
. . . 1 . . . . . 169 715 . . NOZZLE, slip type .500 orf flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . 176 237 . . NOZZLE, spot flat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . 176 239 . . NOZZLE, spot inside corner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 1 . . . 176 241 . . NOZZLE, spot outside corner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . 087 299 . . TIP, contact scr .023 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . 000 067 . . TIP, contact scr .030 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . 000 068 . . TIP, contact scr .035 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . 169 716 . . ADAPTER, contact tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . 170 470 . . RING, retaining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . 170 471 . . O-RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . 169 717 . . WASHER, shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 7 . . . . . 169 718 . . TUBE, head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . 169 738 . . NUT, locking handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 9 . . . . . 169 719 . . NUT, jam (gun end) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . 169 732 . . NUT, jam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . 169 720 . . CONNECTOR, cable (gun end) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . 169 733 . . CONNECTOR, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . 169 721 . . NUT, connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 12 . . . . . 172 017 . . M15 UNICABLE CLAMP KIT, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 13 . . . . . 169 735 . . . . CLIP, compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . 169 742 . . . . TUBE, support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . 169 743 . . . . CLAMP, inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . 169 740 . . . . CLAMP, jacket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . . 169 746 . . . . CONNECTOR, switch lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 18 . . . . . 169 737 . . HANDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 19 . . . . . 169 741 . . STRAIN RELIEF, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 20 . . . . . 180 433 . . CORD, trigger assembly (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . 180 551 . . . . BLOCK, terminal rear inc/dec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . 180 427 . . . . CORD, trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . 173 521 . . CONNECTOR, feeder (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . 079 974 . . . . O-RING, .500 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 25 . . . 172 257 . . KIT, liner monocoil .023/.025 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . . 172 258 . . KIT, liner monocoil .030/.035 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 26 . . . . . 079 975 . . . . O-RING, .187 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 27 . . . . . 169 723 . . GUIDE, outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 28 . . . . . 169 739 . . SWITCH, trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OPTIONAL  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1314 Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item Dia.  
No. Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 7-3. Drive Assembly, Wire (Fig 7-1 Item 1)  
. . . 1 . MOT . 173 446 . . . MOTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . 129 893 . . . INSULATOR, housing drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . 126 838 . . . DRIVE ASSEMBLY, wire (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . 090 416 . . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . 124 817 . . . . HOUSING, wire drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . 151 828 . . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . 112 031 . . . . LEVER, pressure roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . 090 443 . . . . BEARING, ball rdl sgl row .866 OD x .447 width x .315 bore (consisting of) . . 1  
. . . . . . . . . . . . . . 111 622 . . . . . . SPACER, bearing .196 ID x .310 OD x .500 collar . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . 010 224 . . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . . . . 058 549 . . . . GUIDE, wire inlet 1/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . 085 242 . . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . . . . 085 244 . . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . . . . 090 415 . . . . SPRING, cprsn .720 OD x .070 wire x 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . . . 092 237 . . . . KNOB, adj tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . 119 028 . . . ROLL, drive V groove combination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . . . . 602 169 . . . SCREW, set stl sch 8-32 x .187 cup point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 17 . . . . . . . . 114 415 . . . SCREW, mach stl phflh 10-24 x .625 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . 166 575 . . . WRENCH, hex .078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. Hardware is common and  
2
not available unless listed.  
1
3
4
5
Includes Items  
6 thru 14  
17  
14  
13  
12  
11  
6
7
8
SC-121 448-C  
10  
9
16  
15  
Figure 7-3. Drive Assembly, Wire  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-1314 Page 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective January 1, 2000  
(Equipment with a serial number preface of LAor newer)  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
Warranty Questions?  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants  
to its original retail purchaser that new Miller equipment sold  
after the effective date of this limited warranty is free of defects  
in material and workmanship at the time it is shipped by Miller.  
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE  
WARRANTIES OF MERCHANTABILITY AND FITNESS.  
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting  
Torches  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
*
*
*
*
*
Remote Controls  
Accessory Kits  
Replacement Parts (No labor)  
Spoolmate 185 & Spoolmate 250  
Canvas Covers  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to  
such defects in material or workmanship. Miller must be  
notified in writing within thirty (30) days of such defect or  
failure, at which time Miller will provide instructions on the  
warranty claim procedures to be followed.  
Your distributor also gives  
you ...  
Millers True Blue Limited Warranty shall not apply to:  
1. Consumable components; such as contact tips,  
cutting nozzles, contactors, brushes, slip rings,  
relays or parts that fail due to normal wear.  
Service  
You always get the fast,  
reliable response you  
need. Most replacement  
parts can be in your  
hands in 24 hours.  
Miller shall honor warranty claims on warranted equipment  
listed below in the event of such a failure within the warranty  
time periods. All warranty time periods start on the date that  
the equipment was delivered to the original retail purchaser, or  
one year after the equipment is sent to a North American  
distributor or eighteen months after the equipment is sent to an  
International distributor.  
2. Items furnished by Miller, but manufactured by others,  
such as engines or trade accessories. These items are  
covered by the manufacturers warranty, if any.  
Support  
3. Equipment that has been modified by any party other  
than Miller, or equipment that has been improperly  
installed, improperly operated or misused based upon  
industry standards, or equipment which has not had  
reasonable and necessary maintenance, or equipment  
which has been used for operation outside of the  
specifications for the equipment.  
Need fast answers to the  
tough welding questions?  
Contact your distributor.  
The expertise of the  
distributor and Miller is  
there to help you, every  
step of the way.  
1. 5 Years Parts 3 Years Labor  
*
*
Original main power rectifiers  
Inverters (input and output rectifiers only)  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE  
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND  
PERSONS TRAINED AND EXPERIENCED IN THE USE  
AND MAINTENANCE OF WELDING EQUIPMENT.  
2. 3 Years Parts and Labor  
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Supplies  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Millers option: (1) repair; or (2)  
replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the goods  
at customers risk and expense. Millers option of repair or  
replacement will be F.O.B., Factory at Appleton, Wisconsin, or  
F.O.B. at a Miller authorized service facility as determined by  
Miller. Therefore no compensation or reimbursement for  
transportation costs of any kind will be allowed.  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by  
the engine manufacturer.)  
3. 1 Year Parts and Labor  
*
*
DS-2 Wire Feeder  
Motor Driven Guns (w/exception of Spoolmate  
185 & Spoolmate 250)  
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR  
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR  
ANY OTHER LEGAL THEORY.  
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers  
Positioners and Controllers  
Automatic Motion Devices  
RFCS Foot Controls  
Induction Heating Power Sources  
Water Coolant Systems  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN  
AND ANY IMPLIED WARRANTY, GUARANTY OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
Grids  
Maxstar 140  
PROVISION,  
MIGHT  
ARISE  
BY  
IMPLICATION,  
Spot Welders  
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE  
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL  
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND  
DISCLAIMED BY MILLER.  
Load Banks  
Miller Cyclomatic Equipment  
Running Gear/Trailers  
Plasma Cutting Torches (except APT & SAF  
Models)  
Some states in the U.S.A. do not allow limitations of how long  
an implied warranty lasts, or the exclusion of incidental,  
indirect, special or consequential damages, so the above  
limitation or exclusion may not apply to you. This warranty  
provides specific legal rights, and other rights may be  
available, but may vary from state to state.  
*
Field Options  
(NOTE: Field options are covered under True  
Blue for the remaining warranty period of the  
product they are installed in, or for a minimum of  
one year whichever is greater.)  
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated herein,  
and to the extent that they may not be waived, the limitations  
and exclusions set out above may not apply. This Limited  
Warranty provides specific legal rights, and other rights may  
be available, but may vary from province to province.  
4. 6 Months Batteries  
5. 90 Days Parts  
*
*
MIG Guns/TIG Torches  
Induction Heating Coils and Blankets  
miller_warr 7/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owners Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
For Service  
to locate a DISTRIBUTOR or SERVICE AGENCY near you.  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters –  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
www.MillerWelds.com  
Contact the Delivering Carrier for:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims,  
contact your distributor and/or equipment  
manufacturers Transportation Department.  
PRINTED IN USA  
2000 Miller Electric Mfg. Co. 6/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MotoSAT Satellite TV System Nomad 2 User Manual
NEC Car Video System NDA 30135 User Manual
Nikon Camera Flash SB 800 User Manual
NuTone Ventilation Hood PFKB52 Series User Manual
Olympus Microscope Magnifier CS41 User Manual
Omega Engineering Thermometer HH505 User Manual
Oster Food Processor FPSTMC1250 User Manual
Oster Toaster TSSTRTS251 033 User Manual
Panasonic Computer Accessories CF VNP011AU User Manual
Panasonic Switch MA2DF62 User Manual