SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING  
som _3/05  
Y
Warning: Protect yourself and others from injury — read and follow these precautions.  
1-1. Symbol Usage  
Means Warning! Watch Out! There are possible hazards  
with this procedure! The possible hazards are shown in  
the adjoining symbols.  
This group of symbols means Warning! Watch Out! possible  
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  
Consult symbols and related instructions below for necessary actions  
to avoid the hazards.  
Y
Marks a special safety message.  
. Means “Note”; not safety related.  
1-2. Arc Welding Hazards  
Y
The symbols shown below are used throughout this manual to  
call attention to and identify possible hazards. When you see  
the symbol, watch out, and follow the related instructions to  
avoid the hazard. The safety information given below is only  
a summary of the more complete safety information found in  
the Safety Standards listed in Section 1-5. Read and follow all  
Safety Standards.  
D
D
D
D
Turn off all equipment when not in use.  
Do not use worn, damaged, undersized, or poorly spliced cables.  
Do not drape cables over your body.  
If earth grounding of the workpiece is required, ground it directly  
with a separate cable.  
Do not touch electrode if you are in contact with the work, ground,  
or another electrode from a different machine.  
D
D
Y
Y
Only qualified persons should install, operate, maintain, and  
repair this unit.  
Do not touch electrode holders connected to two welding ma-  
chines at the same time since double open-circuit voltage will be  
present.  
During operation, keep everybody, especially children, away.  
D
Use only well-maintained equipment. Repair or replace damaged  
parts at once. Maintain unit according to manual.  
ELECTRIC SHOCK can kill.  
D
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Clamp work cable with good metal-to-metal contact to workpiece  
or worktable as near the weld as practical.  
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
Do not connect more than one electrode or work cable to any  
single weld output terminal.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The electrode and work circuit is  
electrically live whenever the output is on. The input  
power circuit and machine internal circuits are also  
live when power is on. In semiautomatic or automatic wire welding, the  
wire, wire reel, drive roll housing, and all metal parts touching the  
welding wire are electrically live. Incorrectly installed or improperly  
groundedequipment is a hazard.  
D
D
D
D
D
Do not touch live electrical parts.  
Wear dry, hole-free insulating gloves and body protection.  
Insulate yourself from work and ground using dry insulating mats  
or covers big enough to prevent any physical contact with the work  
or ground.  
Do not use AC output in damp areas, if movement is confined, or if  
there is a danger of falling.  
Use AC output ONLY if required for the welding process.  
If AC output is required, use remote output control if present on  
unit.  
SIGNIFICANT DC VOLTAGE exists in inverter-type  
welding power sources after removal of input  
power.  
D
Turn Off inverter, disconnect input power, and discharge input  
capacitors according to instructions in Maintenance Section  
before touching any parts.  
D
D
D
FUMES AND GASES can be hazardous.  
D
Additionalsafety precautions are required when any of the follow-  
ing electrically hazardous conditions are present: in damp  
locations or while wearing wet clothing; on metal structures such  
as floors, gratings, or scaffolds; when in cramped positions such  
as sitting, kneeling, or lying; or when there is a high risk of unavoid-  
able or accidental contact with the workpiece or ground. For these  
conditions, use the following equipment in order presented: 1) a  
semiautomaticDC constant voltage (wire) welder, 2) a DC manual  
(stick) welder, or 3) an AC welder with reduced open-circuit volt-  
age. In most situations, use of a DC, constant voltage wire welder  
is recommended. And, do not work alone!  
Welding produces fumes and gases. Breathing  
these fumes and gases can be hazardous to your  
health.  
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
If inside, ventilate the area and/or use local forced ventilation at the  
arc to remove welding fumes and gases.  
D
D
If ventilation is poor, wear an approved air-supplied respirator.  
Read and understand the Material Safety Data Sheets (MSDSs)  
and the manufacturer’s instructions for metals, consumables,  
coatings, cleaners, and degreasers.  
Work in a confined space only if it is well ventilated, or while  
wearing an air-supplied respirator. Always have a trained watch-  
person nearby. Welding fumes and gases can displace air and  
lower the oxygen level causing injury or death. Be sure the breath-  
ing air is safe.  
Do not weld in locations near degreasing, cleaning, or spraying op-  
erations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
Do not weld on coated metals, such as galvanized, lead, or  
cadmiumplated steel, unless the coating is removed from the weld  
area, the area is well ventilated, and while wearing an air-supplied  
respirator. The coatings and any metals containing these elements  
can give off toxic fumes if welded.  
D
Disconnect input power or stop engine before installing or  
servicing this equipment. Lockout/tagout input power according to  
OSHA 29 CFR 1910.147 (see Safety Standards).  
D
D
D
Properly install and ground this equipment according to its  
Owner’s Manual and national, state, and local codes.  
Always verify the supply ground check and be sure that input  
power cord ground wire is properly connected to ground terminal in  
disconnect box or that cord plug is connected to a properly  
groundedreceptacle outlet.  
D
D
D
D
When making input connections, attach proper grounding conduc-  
tor first double-check connections.  
Frequently inspect input power cord for damage or bare wiring −  
replace cord immediately if damaged bare wiring can kill.  
OM-2241 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ARC RAYS can burn eyes and skin.  
BUILDUP OF GAS can injure or kill.  
D
D
Shut off shielding gas supply when not in use.  
Always ventilate confined spaces or use  
approved air-supplied respirator.  
Arc rays from the welding process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin. Sparks fly off from the  
weld.  
D
Wear an approved welding helmet fitted with a proper shade of fil-  
ter lenses to protect your face and eyes when welding or watching  
(see ANSI Z49.1 and Z87.1 listed in Safety Standards).  
HOT PARTS can cause severe burns.  
D
D
D
Wear approved safety glasses with side shields under your  
helmet.  
D
D
Do not touch hot parts bare handed.  
Allow cooling period before working on gun or  
torch.  
To handle hot parts, use proper tools and/or  
wear heavy, insulated welding gloves and  
clothing to prevent burns.  
Use protective screens or barriers to protect others from flash,  
glare and sparks; warn others not to watch the arc.  
D
Wear protective clothing made from durable, flame-resistant mate-  
rial (leather, heavy cotton, or wool) and foot protection.  
WELDING can cause fire or explosion.  
MAGNETIC FIELDS can affect pacemakers.  
Welding on closed containers, such as tanks,  
drums, or pipes, can cause them to blow up. Sparks  
can fly off from the welding arc. The flying sparks, hot  
workpiece, and hot equipment can cause fires and  
D
D
Pacemaker wearers keep away.  
Wearers should consult their doctor before  
going near arc welding, gouging, or spot  
welding operations.  
burns. Accidental contact of electrode to metal objects can cause  
sparks, explosion, overheating, or fire. Check and be sure the area is  
safe before doing any welding.  
D
Remove all flammables within 35 ft (10.7 m) of the welding arc. If  
this is not possible, tightly cover them with approved covers.  
NOISE can damage hearing.  
D
D
D
Do not weld where flying sparks can strike flammable material.  
Protect yourself and others from flying sparks and hot metal.  
Noise from some processes or equipment can  
damagehearing.  
Be alert that welding sparks and hot materials from welding can  
easily go through small cracks and openings to adjacent areas.  
D
Wear approved ear protection if noise level is  
high.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
Be aware that welding on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
CYLINDERS can explode if damaged.  
D
D
Do not weld on closed containers such as tanks, drums, or pipes,  
unless they are properly prepared according to AWS F4.1 (see  
Safety Standards).  
Shielding gas cylinders contain gas under high  
pressure. If damaged, a cylinder can explode. Since  
gas cylinders are normally part of the welding  
process, be sure to treat them carefully.  
Connect work cable to the work as close to the welding area as  
practical to prevent welding current from traveling long, possibly  
unknown paths and causing electric shock, sparks, and fire  
hazards.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, physical damage, slag, open flames, sparks, and arcs.  
D
D
Do not use welder to thaw frozen pipes.  
Install cylinders in an upright position by securing to a stationary  
support or cylinder rack to prevent falling or tipping.  
Remove stick electrode from holder or cut off welding wire at  
contact tip when not in use.  
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.  
Never drape a welding torch over a gas cylinder.  
D
D
D
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
Never allow a welding electrode to touch any cylinder.  
Never weld on a pressurized cylinder explosion will result.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any welding.  
Use only correct shielding gas cylinders, regulators, hoses, and fit-  
tings designed for the specific application; maintain them and  
associated parts in good condition.  
Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B  
for hot work and have a fire watcher and extinguisher nearby.  
D
D
Turn face away from valve outlet when opening cylinder valve.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
FLYING METAL can injure eyes.  
D
Welding, chipping, wire brushing, and grinding  
cause sparks and flying metal. As welds cool,  
they can throw off slag.  
Wear approved safety glasses with side  
shields even under your welding helmet.  
D
D
Use the right equipment, correct procedures, and sufficient num-  
ber of persons to lift and move cylinders.  
Read and follow instructions on compressed gas cylinders,  
associated equipment, and Compressed Gas Association (CGA)  
publication P-1 listed in Safety Standards.  
D
OM-2241 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Additional Symbols For Installation, Operation, And Maintenance  
FIRE OR EXPLOSION hazard.  
MOVING PARTS can cause injury.  
D
Do not install or place unit on, over, or near  
combustiblesurfaces.  
Do not install unit near flammables.  
D
D
Keep away from moving parts such as fans.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
D
D
D
Have only qualified persons remove doors,  
panels, covers, or guards for maintenance as  
necessary.  
Reinstall doors, panels, covers, or guards  
when maintenance is finished and before re-  
connecting input power.  
D
Do not overload building wiring be sure power supply system is  
properly sized, rated, and protected to handle this unit.  
FALLING UNIT can cause injury.  
D
D
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, or any other accessories.  
Use equipment of adequate capacity to lift and  
support unit.  
If using lift forks to move unit, be sure forks are  
long enough to extend beyond opposite side of  
unit.  
READ INSTRUCTIONS.  
D
Read Owner’s Manual before using or servic-  
ing unit.  
D
Use only genuine Miller/Hobart replacement  
parts.  
H.F. RADIATION can cause interference.  
D
High-frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
Have only qualified persons familiar with  
electronic equipment perform this installation.  
OVERUSE can cause OVERHEATING  
D
D
Allow cooling period; follow rated duty cycle.  
Reduce current or reduce duty cycle before  
starting to weld again.  
D
D
Do not block or filter airflow to unit.  
D
D
The user is responsible for having a qualified electrician prompt-  
ly correct any interference problem resulting from the installa-  
tion.  
If notified by the FCC about interference, stop using the  
equipmentat once.  
STATIC (ESD) can damage PC boards.  
D
D
Have the installation regularly checked and maintained.  
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
D
ARC WELDING can cause interference.  
MOVING PARTS can cause injury.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
Be sure all equipment in the welding area is  
electromagneticallycompatible.  
D
D
Keep away from moving parts.  
Keep away from pinch points such as drive  
rolls.  
D
D
D
D
D
To reduce possible interference, keep weld cables as short as  
possible, close together, and down low, such as on the floor.  
Locate welding operation 100 meters from any sensitive elec-  
tronic equipment.  
WELDING WIRE can cause injury.  
D
Do not press gun trigger until instructed to do  
so.  
Be sure this welding machine is installed and grounded  
according to this manual.  
D
Do not point gun toward any part of the body,  
other people, or any metal when threading  
welding wire.  
If interference still occurs, the user must take extra measures  
such as moving the welding machine, using shielded cables,  
using line filters, or shielding the work area.  
1-4. California Proposition 65 Warnings  
Y
Welding or cutting equipment produces fumes or gases which  
contain chemicals known to the State of California to cause  
birth defects and, in some cases, cancer. (California Health &  
Safety Code Section 25249.5 et seq.)  
For Gasoline Engines:  
Y
Engine exhaust contains chemicals known to the State of  
California to cause cancer, birth defects, or other reproductive  
harm.  
For Diesel Engines:  
Y
Battery posts, terminals and related accessories contain lead  
and lead compounds, chemicals known to the State of  
California to cause cancer and birth defects or other  
reproductiveharm. Wash hands after handling.  
Y
Diesel engine exhaust and some of its constituents are known  
to the State of California to cause cancer, birth defects, and  
other reproductive harm.  
OM-2241 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1-5. Principal Safety Standards  
Safety inWelding, Cutting, and Allied Processes, ANSI Standard Z49.1,  
from Global Engineering Documents (phone: 1-877-413-5184, website:  
www.global.ihs.com).  
Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone:  
8004636727 or in Toronto 4167474044, website: www.csain-  
ternational.org).  
Practice For Occupational And Educational Eye And Face Protection,  
ANSI Standard Z87.1, from American National Standards Institute, 11  
West 42nd Street, New York, NY 100368002 (phone: 2126424900,  
website: www.ansi.org).  
Recommended Safe Practices for the Preparation for Weldingand Cut-  
ting of Containers and Piping, American Welding Society Standard  
AWS F4.1 from Global Engineering Documents (phone:  
1-877-413-5184,website: www.global.ihs.com).  
Standard for Fire Prevention During Welding, Cutting, and Other Hot  
Work, NFPA Standard 51B, from National Fire Protection Association,  
P.O. Box 9101, 1 Battery March Park, Quincy, MA 022699101 (phone:  
6177703000,website: www.nfpa.org).  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA  
022699101(phone: 6177703000, website: www.nfpa.org).  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 1735 Jefferson Davis Highway,  
Suite 1004, Arlington, VA 222024102 (phone: 7034120900, web-  
site: www.cganet.com).  
OSHA, Occupational Safety and Health Standards for General Indus-  
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,  
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-  
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there  
are 10 Regional Offices−−phone for Region 5, Chicago, is  
3123532220,website: www.osha.gov).  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
Canadian Standards Association, Standards Sales, 178 Rexdale  
1-6. EMF Information  
Considerations About Welding And The Effects Of Low Frequency  
Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding current, as it flows through welding cables, will cause electro-  
magnetic fields. There has been and still is some concern about such  
fields. However, after examining more than 500 studies spanning 17  
years of research, a special blue ribbon committee of the National  
Research Council concluded that: “The body of evidence, in the  
committees judgment, has not demonstrated that exposure to power-  
frequency electric and magnetic fields is a human-health hazard.”  
However, studies are still going forth and evidence continues to be  
examined.Until the final conclusions of the research are reached, you  
may wish to minimize your exposure to electromagnetic fields when  
welding or cutting.  
4. Keep welding power source and cables as far away from opera-  
tor as practical.  
5. Connect work clamp to workpiece as close to the weld as possi-  
ble.  
About Pacemakers:  
Pacemaker wearers consult your doctor before welding or going near  
welding operations. If cleared by your doctor, then following the above  
procedures is recommended.  
To reduce magnetic fields in the workplace, use the following  
procedures:  
OM-2241 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 2 CONSIGNES DE SÉCURITÉ LIRE AVANT UTILISATION  
fre_som _3/05  
Y
Avertissement: se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.  
2-1. Symboles utilisés  
Symbole graphique d’avertissement ! Attention ! Cette pro-  
cédure comporte des risques possibles ! Les dangers éven-  
tuels sont représentés par les symboles graphiques joints.  
Ce groupe de symboles signifie Avertissement ! Attention ! Risques  
d’ÉLECTROCUTION, ORGANES MOBILES et PARTIES  
CHAUDES. Consulter les symboles et les instructions afférentes  
ci-dessous concernant les mesures à prendre pour supprimer  
les dangers.  
Y
Indique un message de sécurité particulier  
. Signifie NOTE ; n’est pas relatif à la sécurité.  
2-2. Dangers relatifs au soudage à l’arc  
Y
Les symboles représentés ci-dessous sont utilisés dans ce manuel  
pour attirer l’attention et identifier les dangers possibles. En  
présence de l’un de ces symboles, prendre garde et suivre les  
instructions afférentes pour éviter tout risque. Les instructions en  
matière de sécurité indiquées ci-dessous ne constituent qu’un  
sommaire des instructions de sécurité plus complètes fournies  
dans les normes de sécurité énumérées dans la Section 2-5. Lire et  
observer toutes les normes de sécurité.  
Seul un personnel qualifié est autorisé à installer, faire fonction-  
ner, entretenir et réparer cet appareil.  
Pendant le fonctionnement, maintenir à distance toutes les per-  
sonnes, notamment les enfants de l’appareil.  
D
Vérifier fréquemment le cordon d’alimentation afin de s’assurer qu’il  
n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est. Un fil à nu  
peut entraîner la mort.  
L’équipement doit être hors tension lorsqu’il n’est pas utilisé.  
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante  
ou mal épissés.  
Ne pas enrouler les câbles autour du corps.  
Si la pièce soudée doit être mise à la terre, le faire directement avec un  
câble distinct.  
Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre  
ou une électrode provenant d’une autre machine.  
Ne pas toucher des porte électrodes connectés à deux machines en  
même temps à cause de la présence d’une tension à vide doublée.  
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-  
champ les pièces endommagées. Entretenir l’appareil conformément à  
ce manuel.  
Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.  
S’assurer que tous les panneaux et couvercles sont correctement en  
place.  
Fixer le câble de retour de façon à obtenir un bon contact métal-métal  
avec la pièce à souder ou la table de travail, le plus près possible de la  
soudure.  
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact  
avec tout objet métallique.  
D
D
D
D
Y
Y
D
D
D
UNE DÉCHARGE ÉLECTRIQUE peut  
entraîner la mort.  
Le contact d’organes électriques sous tension peut  
provoquer des accidents mortels ou des brûlures  
graves. Le circuit de l’électrode et de la pièce est  
sous tension lorsque le courant est délivré à la  
D
D
D
sortie. Le circuit d’alimentation et les circuits internes de la machine  
sont également sous tension lorsque l’alimentation est sur Marche.  
Dans le mode de soudage avec du fil, le fil, le dérouleur, le bloc de  
commande du rouleau et toutes les parties métalliques en contact  
avec le fil sont sous tension électrique. Un équipement installé ou mis  
à la terre de manière incorrecte ou impropre constitue un danger.  
D
D
Ne pas raccorder plus d’une électrode ou plus d’un câble de masse à  
une même borne de sortie de soudage.  
D
D
Ne pas toucher aux pièces électriques sous tension.  
Porter des gants isolants et des vêtements de protection secs et sans  
trous.  
S’isoler de la pièce à couper et du sol en utilisant des housses ou des  
tapis assez grands afin d’éviter tout contact physique avec la pièce à  
couper ou le sol.  
Ne pas se servir de source électrique à courant électrique dans les zo-  
nes humides, dans les endroits confinés ou là où on risque de tomber.  
Se servir d’une source électrique à courant électrique UNIQUEMENT si  
le procédé de soudage le demande.  
Si l’utilisation d’une source électrique à courant électrique s’avère né-  
cessaire, se servir de la fonction de télécommande si l’appareil en est  
équipé.  
Il reste une TENSION DC NON NÉGLIGEABLE dans  
les sources de soudage onduleur quand on a coupé  
l’alimentation.  
D
D
Arrêter les convertisseurs, débrancher le courant électrique et  
décharger les condensateurs d’alimentation selon les instructions indi-  
quées dans la partie Entretien avant de toucher les pièces.  
D
D
D
LES FUMÉES ET LES GAZ peuvent  
être dangereux.  
Le soudage génère des fumées et des gaz. Leur  
inhalationpeut être dangereuse pour la santé.  
D
D’autres consignes de sécurité sont nécessaires dans les conditions  
suivantes : risques électriques dans un environnement humide ou si l’on  
porte des vêtements mouillés ; sur des structures métalliques telles que  
sols, grilles ou échafaudages ; en position coincée comme assise, à ge-  
noux ou couchée ; ou s’il y a un risque élevé de contact inévitable ou  
accidentel avec la pièce à souder ou le sol. Dans ces conditions, utiliser  
les équipements suivants, dans l’ordre indiqué : 1) un poste à souder DC  
à tension constante (à fil), 2) un poste à souder DC manuel (électrode)  
ou 3) un poste à souder AC à tension à vide réduite. Dans la plupart des  
situations, l’utilisation d’un poste à souder DC à fil à tension constante  
est recommandée. En outre, ne pas travailler seul !  
Couper l’alimentation ou arrêter le moteur avant de procéder  
à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller  
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de  
sécurité).  
Installer le poste correctement et le mettre à la terre convenablement  
selon les consignes du manuel de l’opérateur et les normes nationales,  
provinciales et locales.  
D
D
D
D
Ne pas mettre sa tête au-dessus des vapeurs. Ne pas respirer ces va-  
peurs.  
À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au niveau de  
l’arc pour l’évacuation des fumées et des gaz de soudage.  
Si la ventilation est médiocre, porter un respirateur anti-vapeurs approu-  
vé.  
Lire et comprendre les spécifications de sécurité des matériaux (MSDS) et  
les instructions du fabricant concernant les métaux, les consommables, les  
revêtements, les nettoyants et les dégraisseurs.  
Travailler dans un espace fermé seulement s’il est bien ventilé ou en  
portant un respirateur à alimentation d’air. Demander toujours à un sur-  
veillant dûment formé de se tenir à proximité. Des fumées et des gaz de  
soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provo-  
quant des blessures ou des accidents mortels. S’assurer que l’air de  
respiration ne présente aucun danger.  
Ne pas souder dans des endroits situés à proximité d’opérations de dé-  
graissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de  
l’arc peuvent réagir en présence de vapeurs et former des gaz haute-  
ment toxiques et irritants.  
Ne pas souder des métaux munis d’un revêtement, tels que l’acier gal-  
vanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait  
été enlevé dans la zone de soudure, que l’endroit soit bien ventilé et en  
portant un respirateur à alimentation d’air. Les revêtements et tous les  
métaux renfermant ces éléments peuvent dégager des fumées toxi-  
ques en cas de soudage.  
D
D
D
D
D
D
Toujours vérifier la terre du cordon d’alimentation. Vérifier et s’assurer  
que le fil de terre du cordon d’alimentation est bien raccordé à la borne  
de terre du sectionneur ou que la fiche du cordon est raccordée à une  
prise correctement mise à la terre.  
En effectuant les raccordements d’entrée, fixer d’abord le conducteur  
de mise à la terre approprié et contre-vérifier les connexions.  
D
OM-2241 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LES RAYONS D’ARC peuvent entraî-  
ner des brûlures aux yeux et à la peau.  
LES ACCUMULATIONS DE GAZ  
risquent de provoquer des blessures  
ou même la mort.  
Le rayonnement de l’arc du procédé de soudage  
génère des rayons visibles et invisibles intenses  
(ultraviolets et infrarouges) susceptibles de provo-  
quer des brûlures dans les yeux et sur la peau.  
D
Fermer l’alimentation du gaz protecteur en cas  
de non-utilisation.  
D
Veiller toujours à bien aérer les espaces confi-  
nés ou se servir d’un respirateur d’adduction  
d’air homologué.  
Des étincelles sont projetées pendant le soudage.  
D
Porter un casque de soudage approuvé muni de verres filtrants ap-  
proprié pour protéger visage et yeux pendant le soudage (voir ANSI  
Z49.1 et Z87.1 énuméré dans les normes de sécurité).  
D
D
Porter des lunettes de sécurité avec écrans latéraux même sous vo-  
DES PIÈCES CHAUDES peuvent  
provoquer des brûlures graves.  
tre casque.  
Avoir recours à des écrans protecteurs ou à des rideaux pour  
protéger les autres contre les rayonnements les éblouissements et  
les étincelles ; prévenir toute personne sur les lieux de ne pas  
regarder l’arc.  
Porter des vêtements confectionnés avec des matières résistantes  
et ignifuges (cuir, coton lourd ou laine) et des bottes de protection.  
D
Ne pas toucher des parties chaudes à mains  
nues.  
D
Prévoir une période de refroidissement avant  
d’utiliser le pistolet ou la torche.  
D
D
Ne pas toucher aux pièces chaudes, utiliser les outils recom-  
mandés et porter des gants de soudage et des vêtements épais  
pour éviter les brûlures.  
LE SOUDAGE peut provoquer un  
incendie ou une explosion.  
Le soudage effectué sur des conteneurs fermés tels  
que des réservoirs, tambours ou des conduites peut  
provoquer leur éclatement. Des étincelles peuvent  
être projetées de l’arc de soudure. La projection  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
D
Porteurs de stimulateur cardiaque, rester  
à distance.  
d’étincelles,des pièces chaudes et des équipements chauds peuvent  
provoquer des incendies et des brûlures. Le contact accidentel de  
l’électrodeavec des objets métalliques peut provoquer des étincelles,  
une explosion, une surchauffe ou un incendie. Avant de commencer  
le soudage, vérifier et s’assurer que l’endroit ne présente pas de  
danger.  
D
Les porteurs d’un stimulateur cardiaque doi-  
vent d’abord consulter leur médecin avant de  
s’approcherdes opérations de soudage à l’arc,  
de gougeage ou de soudage par points.  
D
Déplacer toutes les substances inflammables à une distance de  
10,7 m de l’arc de soudage. En cas d’impossibilité, les recouvrir soi-  
gneusementavec des protections homologuées.  
LE BRUIT peut endommager l’ouïe.  
Le bruit des processus et des équipements peut  
affecter l’ouïe.  
D
D
D
Ne pas souder dans un endroit où des étincelles peuvent tomber sur  
des substances inflammables.  
Se protéger, ainsi que toute autre personne travaillant sur les lieux,  
contre les étincelles et le métal chaud.  
Des étincelles et des matériaux chauds du soudage peuvent  
facilement passer dans d’autres zones en traversant de petites  
fissures et des ouvertures.  
Afin d’éliminer tout risque de feu, être vigilant et garder toujours un  
extincteur à la portée de main.  
Le soudage effectué sur un plafond, plancher, paroi ou séparation  
peut déclencher un incendie de l’autre côté.  
Ne pas effectuer le soudage sur des conteneurs fermés tels que des  
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-  
rés correctement conformément à AWS F4.1 (voir les normes de  
sécurité).  
Brancher le câble de masse sur la pièce le plus près possible de la  
zone de soudage pour éviter le transport du courant sur une longue  
distance par des chemins inconnus éventuels en provoquant des  
risques d’électrocution, d’étincelles et d’incendie.  
Ne pas utiliser le poste de soudage pour dégeler des conduites  
gelées.  
En cas de non-utilisation, enlever la baguette d’électrode du porte-  
électrode ou couper le fil à la pointe de contact.  
Porter des vêtements de protection exempts d’huile tels que des  
gants en cuir, une veste résistante, des pantalons sans revers, des  
bottes et un casque.  
D
Porter des protections approuvées pour les  
oreilles si le niveau sonore est trop élevé.  
LES BOUTEILLES peuvent exploser  
si elles sont endommagées.  
D
D
D
Des bouteilles de gaz protecteur contiennent du gaz  
sous haute pression. Si une bouteille est endomma-  
gée, elle peut exploser. Du fait que les bouteilles de  
gaz font normalement partie du procédé de soudage,  
les manipuler avec précaution.  
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessi-  
ve, des chocs mécaniques, des dommages physiques, du lai-  
tier, des flammes ouvertes, des étincelles et des arcs.  
Placer les bouteilles debout en les fixant dans un support sta-  
tionnaireou dans un porte-bouteilles pour les empêcher de tom-  
ber ou de se renverser.  
Tenir les bouteilles éloignées des circuits de soudage ou autres  
circuits électriques.  
Ne jamais placer une torche de soudage sur une bouteille à gaz.  
D
D
D
D
D
D
Une électrode de soudage ne doit jamais entrer en contact avec  
une bouteille.  
D
D
Avant de souder, retirer toute substance combustible de ses poches  
D
D
Ne jamais souder une bouteille pressurisée risque d’explosion.  
telles qu’un allumeur au butane ou des allumettes.  
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,  
tuyaux et raccords convenables pour cette application spécifi-  
que ; les maintenir ainsi que les éléments associés en bon état.  
Détourner votre visage du détendeur-régulateur lorsque vous  
ouvrez la soupape de la bouteille.  
Le couvercle du détendeur doit toujours être en place, sauf lors-  
que la bouteille est utilisée ou qu’elle est reliée pour usage ulté-  
rieur.  
Utiliser les équipements corrects, les bonnes procédures et suf-  
fisammentde personnes pour soulever et déplacer les bouteil-  
les.  
Lire et suivre les instructions sur les bouteilles de gaz comprimé,  
l’équipement connexe et le dépliant P-1 de la CGA (Compressed  
Gas Association) mentionné dans les principales normes de sécuri-  
té.  
Suivre les consignes de OSHA 1910.252 (a) (2) (iv) et de NFPA 51B  
pour travaux de soudage et prévoir un détecteur d’incendie et un ex-  
tincteur à proximité.  
D
D
DES  
PARTICULES  
VOLANTES  
peuvent blesser les yeux.  
D
Le soudage, l’écaillement, le passage de la  
pièce à la brosse en fil de fer, et le meulage  
génèrent des étincelles et des particules  
métalliques volantes. Pendant la période de  
refroidissement des soudures, elles risquent  
de projeter du laitier.  
D
D
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran  
facial.  
OM-2241 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance  
Risque D’INCENDIE OU D’EXPLO-  
SION.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Ne pas placer l’appareil sur, au-dessus ou  
à proximité de surfaces inflammables.  
D
S’abstenirde toucher des organes mobiles tels  
que des ventilateurs.  
D
Ne pas installer l’appareil à proximité de  
produits inflammables.  
D
Maintenir fermés et verrouillés les portes,  
panneaux, recouvrements et dispositifs de  
protection.  
D
Ne pas surcharger l’installation électrique s’assurer que  
l’alimentationest correctement dimensionnée et protégée avant  
de mettre l’appareil en service.  
D
D
Seules des personnes qualifiées sont autorisées à enlever les  
portes, panneaux, recouvrements ou dispositifs de protection  
pour l’entretien.  
Remettreles portes, panneaux, recouvrements ou dispositifs de  
protection quand l’entretien est terminé et avant de rebrancher  
l’alimentation électrique.  
LA CHUTE DE L’APPAREIL peut  
blesser.  
LIRE LES INSTRUCTIONS.  
D
Utiliser l’anneau de levage uniquement pour  
soulever l’appareil, NON PAS les chariots, les  
bouteilles de gaz ou tout autre accessoire.  
Utiliser un équipement de levage de capacité  
suffisante pour lever l’appareil.  
D
Lire le manuel d’utilisation avant d’utiliser ou  
d’intervenirsur l’appareil.  
D
D
Utiliser uniquement des pièces de rechange  
Miller/Hobart.  
D
En utilisant des fourches de levage pour déplacer l’unité, s’assu-  
rer que les fourches sont suffisamment longues pour dépasser  
du côté opposé de l’appareil.  
LE  
RAYONNEMENT  
HAUTE  
FRÉQUENCE (HF) risque de provoquer  
des interférences.  
L’EMPLOI EXCESSIF peut SUR-  
CHAUFFER L’ÉQUIPEMENT.  
D
Le rayonnement haute fréquence (HF) peut  
provoquer des interférences avec les équipe-  
ments de radio-navigation et de communica-  
tion, les services de sécurité et les ordinateurs.  
D
D
D
Prévoir une période de refroidissement ;  
respecter le cycle opératoire nominal.  
D
Demander seulement à des personnes qualifiées familiarisées  
avec des équipements électroniques de faire fonctionner l’instal-  
lation.  
L’utilisateurest tenu de faire corriger rapidement par un électri-  
cien qualifié les interférences résultant de l’installation.  
Si le FCC signale des interférences, arrêter immédiatement  
l’appareil.  
Effectuer régulièrement le contrôle et l’entretien de l’installation.  
Maintenirsoigneusement fermés les portes et les panneaux des  
sources de haute fréquence, maintenir les éclateurs à une  
distance correcte et utiliser une terre et un blindage pour réduire  
les interférences éventuelles.  
Réduire le courant ou le facteur de marche  
avant de poursuivre le soudage.  
Ne pas obstruer les passages d’air du poste.  
D
D
LES CHARGES ÉLECTROSTATIQUES  
peuvent endommager les circuits  
imprimés.  
D
D
D
Établir la connexion avec la barrette de terre  
avant de manipuler des cartes ou des pièces.  
D
Utiliser des pochettes et des boîtes antistati-  
ques pour stocker, déplacer ou expédier des  
cartes PC.  
LE SOUDAGE À L’ARC risque de  
provoquer des interférences.  
D
L’énergie électromagnétique peut gêner le  
fonctionnement d’appareils électroniques  
comme des ordinateurs et des robots.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Veiller à ce que tout l’équipement de la zone de  
D
Ne pas s’approcher des organes mobiles.  
soudage soit compatible électromagnétiquement.  
D
Ne pas s’approcher des points de coincement  
tels que des rouleaux de commande.  
D
Pour réduire la possibilité d’interférence, maintenir les câbles de  
soudage aussi courts que possible, les grouper, et les poser  
aussi bas que possible (ex. par terre).  
D
D
D
Veiller à souder à une distance de 100 mètres de tout équipe-  
LES FILS DE SOUDAGE peuvent  
provoquer des blessures.  
ment électronique sensible.  
Veiller à ce que ce poste de soudage soit posé et mis à la terre  
conformément à ce mode d’emploi.  
En cas d’interférences après avoir pris les mesures précéden-  
tes, il incombe à l’utilisateur de prendre des mesures supplé-  
mentaires telles que le déplacement du poste, l’utilisation de  
câbles blindés, l’utilisation de filtres de ligne ou la pose de protec-  
teurs dans la zone de travail.  
D
Ne pas appuyer sur la gâchette avant d’en  
avoir reçu l’instruction.  
D
Ne pas diriger le pistolet vers soi, d’autres  
personnes ou toute pièce mécanique en enga-  
geant le fil de soudage.  
2-4. Proposition californienne 65 Avertissements  
Y
Les équipements de soudage et de coupage produisent des Pour les moteurs à essence :  
fumées et des gaz qui contiennent des produits chimiques dont  
Y
Les gaz d’échappement des moteurs contiennent des produits  
l’État de Californie reconnaît qu’ils provoquent des malformations  
congénitales et, dans certains cas, des cancers. (Code de santé et  
de sécurité de Californie, chapitre 25249.5 et suivants)  
chimiques dont l’État de Californie reconnaît qu’ils provoquent  
des cancers et des malformations congénitales ou autres pro-  
blèmes de procréation.  
Pour les moteurs diesel :  
Y
Les batteries, les bornes et autres accessoires contiennent du  
plomb et des composés à base de plomb, produits chimiques  
dont l’État de Californie reconnaît qu’ils provoquent des can-  
cers et des malformations congénitales ou autres problèmes de  
procréation. Se laver les mains après manipulation.  
Y
Les gaz d’échappement des moteurs diesel et certains de leurs  
composants sont reconnus par l’État de Californie comme  
provoquant des cancers et des malformations congénitales ou au-  
tres problèmes de procréation.  
OM-2241 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2-5. Principales normes de sécurité  
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, Boulevard, Rexdale, Ontario, Canada M9W 1R3 (téléphone  
:
:
de Global Engineering Documents (téléphone : 1-877-413-5184, site In- 800-463-6727 ou  
à
Toronto 416-747-4044, site Internet  
ternet : www.global.ihs.com).  
www.csa-international.org).  
Practice For Occupational And Educational Eye And Face Protection,  
ANSI Standard Z87.1, de American National Standards Institute, 11 West  
42nd Street, New York, NY 10036-8002 (téléphone : 212-642-4900, site  
Internet : www.ansi.org).  
Recommended Safe Practices for the Preparation for Welding and Cut-  
ting of Containers and Piping, American Welding Society Standard AWS  
F4.1 de Global Engineering Documents (téléphone : 1-877-413-5184, site  
Internet : www.global.ihs.com).  
Standard for Fire Prevention During Welding, Cutting, and Other Hot  
Work, NFPA Standard 51B, de National Fire Protection Association, P.O.  
Box 9101, 1 Battery March Park, Quincy, MA 02269-9101 (téléphone :  
617-770-3000,site Internet : www.nfpa.org).  
National Electrical Code, NFPA Standard 70, de National Fire Protection  
Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA  
02269-9101(téléphone : 617-770-3000, site Internet : www.nfpa.org).  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de Compressed Gas Association, 1735 Jefferson Davis Highway, Suite  
1004, Arlington, VA 22202-4102 (téléphone : 703-412-0900, site Internet  
: www.cganet.com).  
OSHA, Occupational Safety and Health Standards for General Industry,  
Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and  
Part 1926, Subpart J, de U.S. Government Printing Office, Superinten-  
dent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (il y a 10  
Code for Safety in Welding and Cutting, CSA Standard W117.2, de bureaux régionaux−−le téléphone de la région 5, Chicago, est  
Canadian Standards Association, Standards Sales, 178 Rexdale 312-353-2220,site Internet : www.osha.gov).  
2-6. Information EMF  
Considérationssur le soudage et les effets de basse fréquence et des 1. Maintenir les câbles ensemble en les tordant ou en les enveloppant.  
champs magnétiques et électriques.  
2. Disposer les câbles d’un côté et à distance de l’opérateur.  
Le courant de soudage, pendant son passage dans les câbles de souda-  
ge, causera des champs électromagnétiques. Il y a eu et il y a encore un  
3. Ne pas courber pas et ne pas entourer pas les câbles autour de  
certain souci à propos de tels champs. Cependant, après avoir examiné  
votre corps.  
plus de 500 études qui ont été faites pendant une période de recherche  
de 17 ans, un comité spécial ruban bleu du National Research Council a  
4. Garder le poste de soudage et les câbles le plus loin possible de  
conclu : « L’accumulation de preuves, suivant le jugement du comité, n’a  
vous.  
pas démontré que l’exposition aux champs magnétiques et champs élec-  
triques à haute fréquence représente un risque à la santé humaine ».  
5. Connecter la pince sur la pièce aussi près que possible de la sou-  
Toutefois, des études sont toujours en cours et les preuves continuent à  
dure.  
être examinées. En attendant que les conclusions finales de la recherche  
soient établies, il vous serait souhaitable de réduire votre exposition aux  
champs électromagnétiques pendant le soudage ou le coupage.  
En ce qui concerne les stimulateurs cardiaques  
Les porteurs de stimulateur cardiaque doivent consulter leur médecin  
Pour réduire les champs magnétiques sur le poste de travail, appliquer avant de souder ou d’approcher des opérations de soudage. Si le méde-  
les procédures suivantes :  
cin approuve, il est recommandé de suivre les procédures précédentes.  
OM-2241 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 3 INSTALLATION  
3-1. Specifications  
Amperes Input at Rated Load Output,  
60 Hz, Three-Phase  
Voltage Range  
230 V  
460 V  
575 V  
KVA  
KW  
DC  
Rated Welding Output  
Max OCV DC  
375 A @ 35 Volts DC,  
100% Duty Cycle  
69  
4*  
34.5  
2*  
27.5  
1.6*  
27.5  
1.61*  
17.5  
0.46*  
10 45  
45  
*While idling  
3-2. Duty Cycle And Overheating  
Duty Cycle is percentage of 10 min-  
utes that unit can weld at rated load  
without overheating.  
If unit overheats, thermostat(s)  
opens, output stops, and cooling  
fan runs. Wait fifteen minutes for  
unit to cool. Reduce amperage or  
duty cycle before welding.  
Y
Exceeding duty cycle can  
damage unit and void  
warranty.  
100% Duty Cycle  
ContinuousWelding  
0
Overheating  
V
15  
OR  
Reduce Duty Cycle  
Minutes  
209 810  
OM-2241 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-3. Volt-Ampere Curves  
Volt-ampere curves show mini-  
mum and maximum voltage and  
amperage output capabilities of  
unit. Curves of other settings fall be-  
tween curves shown.  
60  
50  
40  
30  
20  
10  
0
MAX  
MIN  
0
100  
200  
300  
400  
500  
600  
700  
800  
DC Amperes  
209 811  
OM-2241 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-4. Selecting A Location  
1
2
Lifting Eye  
Lifting Forks  
Use lifting eye or lifting forks to  
move unit.  
Movement  
If using lifting forks, extend forks  
beyond opposite side of unit.  
1
3
Rating Label (Non CE Models  
Only)  
Use rating label to determine input  
power needs. Label located under  
front access door.  
OR  
2
4
Plate Label (CE Models Only)  
Label located under front access  
door.  
Location And Airflow  
5
Rating Label (CE Models  
Only)  
6
Use rating label to determine input  
power needs. Label located on rear  
access door.  
3
6
Line Disconnect Device  
Locate unit near correct input pow-  
er supply.  
18 in  
(460 mm)  
Y
Special installation may be  
required where gasoline or  
volatile liquids are present −  
see NEC Article 511 or CEC  
Section 20.  
4
5
18 in  
(460 mm)  
Ref. 800 453-A  
3-5. Tipping  
Y
Be careful when placing or  
moving unit over uneven  
surfaces.  
OM-2241 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-6. Dimensions And Weights  
Dimensions  
A
A
B
30 in (762 mm) including lift eye  
23 in (585 mm)  
C
30-1/2 in (775 mm) including  
strain relief  
B
C
D
E
F
27-1/2 in (699 mm)  
3/4 in (19 mm)  
F
G
H
4 Holes  
21-1/8 in (537 mm)  
1-1/8 in (29 mm)  
7/16 in (11 mm) Dia  
Weight  
G
H
D
381 lb (173 kg)  
E
801 530  
3-7. 115 VAC Receptacle And Supplementary Protectors  
Y
Turn Off power before con-  
necting to receptacle.  
1
115 V 15 A AC Receptacle  
RC9  
Power is shared between RC9 and  
Remote 14 receptacle RC8 (see  
Section 3-10).  
3
2
2
3
Supplementary Protector CB1  
Supplementary Protector CB2  
CB1 protects the 115 volts ac por-  
tion of RC8 and RC9 from overload.  
CB2 protects the 24 volts ac portion  
of RC8 from overload.  
1
Press button to reset protector.  
Ref. ST-800 166-D  
OM-2241 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-8. Weld Output Terminals And Selecting Cable Sizes  
Total Cable (Copper) Length In Weld Circuit Not Exceeding  
150 ft  
(45 m)  
200 ft  
(60 m)  
250 ft  
(70 m)  
300 ft  
(90 m)  
350 ft  
(105 m)  
400 ft  
(120 m)  
100 ft (30 m) Or Less  
Y
Y
Turn off power before  
connectingto weld out-  
put terminals.  
Welding  
10 60%  
60 100%  
Duty Cycle  
10 100% Duty Cycle  
Amperes Duty Cycle  
Do not use worn, dam-  
aged, undersized, or  
poorly spliced cables.  
100  
150  
200  
250  
300  
350  
400  
500  
600  
700  
4
3
4
3
4
2
3
2
1
1/0  
1/0  
1
1/0  
2/0  
3/0  
3/0  
3
2
1
1/0  
2/0  
3/0  
4/0  
4/0  
2
1
1/0  
2/0  
3/0  
3/0  
4/0  
2-2/0  
2-3/0  
2/0  
3/0  
4/0  
2-2/0  
2-3/0  
2-3/0  
2-4/0  
3-3/0  
3-4/0  
3-4/0  
2-2/0  
2-3/0  
2-4/0  
2-4/0  
3-3/0  
3-4/0  
4-4/0  
1
1/0  
2/0  
2/0  
3/0  
4/0  
2-2/0  
3/0  
4/0  
2-2/0  
2-3/0  
2-3/0  
2-4/0  
3-3/0  
3-4/0  
1/0  
1/0  
2/0  
3/0  
4/0  
4/0  
2-2/0  
2-2/0  
2-3/0  
2-4/0  
3-3/0  
4/0  
Negative  
Stainless Steel/  
Aluminum  
2-2/0  
2-3/0  
2-4/0  
All Other  
Materials  
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for  
2
the mm equivalent weld cable sizes.  
S-0007-E  
3-9. Connecting Weld Output Cables  
4
1
Do not place  
anything between  
weld cable terminal  
and copper bar.  
2
3
Tools Needed:  
3/4 in (19 mm)  
803 778-B  
Correct Installation  
Incorrect Installation  
Y
Y
Turn off power before connecting to  
weld output terminals.  
1
2
3
4
Weld Output Terminal  
Supplied Weld Output Terminal Nut  
Weld Cable Terminal  
Copper Bar  
minal. Slide weld cable terminal onto weld  
output terminal and secure with nut so that  
weld cable terminal is tight against copper  
bar. Do not place anything between weld  
cable terminal and copper bar. Make  
sure that the surfaces of the weld cable  
terminal and copper bar are clean.  
Failure to properly connect weld  
cables may cause excessive heat  
and start a fire, or damage your ma-  
chine.  
Remove supplied nut from weld output ter-  
OM-2241 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-10. Remote 14 Receptacle RC8  
Y
Turn off power before con-  
necting to receptacle.  
1
Remote 14 Receptacle RC8  
Connect feeder to RC8.  
1
A
J
K
I
B
C
L
N
H
M
D
G
F
E
Ref. 800 166-D  
3-11. Remote 14 Receptacle RC8 Information  
Socket  
Information  
A
B
C
D
E
F
H
I
24 volts ac. Protected by supplementary protector CB2.  
Contact closure to A completes 24 volts ac contactor control circuit.  
Command reference; 0 to +10 volts dc.  
24 VOLTS AC  
Remote control circuit common.  
REMOTE OUTPUT CONTROL  
0 to +10 volts dc input command signal from remote control.  
Current feedback; 1 volt per 100 amperes.  
Voltage feedback; 1 volt per 10 arc volts.  
115 volts, 15 amperes, 60 Hz ac. Protected by supplementary protector CB1.  
Contact closure to I completes 115 volts ac contactor control circuit.  
115 VOLTS AC  
GND  
J
K
Chassis common.  
G
Circuit common for 24 and 115 volts ac circuits.  
To remote On/Off switch.  
REMOTE POWER ON/OFF  
*
*
*
Voltage sensing signal from Negative () weld output terminal.  
REMOTE VOLTAGE SENSING  
Voltage sensing signal from Positive (+) weld output terminal.  
* Not Used  
OM-2241 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-12. Electrical Service Guide  
Input Voltage  
230  
69  
460  
575  
Input Amperes At Rated Output  
34.5  
27.5  
1
Max Recommended Standard Fuse Rating In Amperes  
2
80  
100  
4
40  
50  
8
30  
40  
10  
Time-Delay  
Normal Operating 3  
Min Input Conductor Size In AWG 4  
237  
(72)  
422  
444  
Max Recommended Input Conductor Length In Feet (Meters)  
Min Grounding Conductor Size In AWG 4  
(129)  
(135)  
8
10  
10  
Reference: 2005 National Electrical Code (NEC)  
1 Consult factory for circuit breaker applications.  
2 “Time-Delay” fuses are UL class “RK5” .  
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and  
above).  
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table  
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.  
3-13. Placing Jumper Links  
Y
Disconnect and lockout/tag-  
out input power before  
installing or moving jumper  
links.  
Check input voltage available at  
site.  
1
Jumper Link Label  
Check label only one is on unit.  
Jumper Links  
2
Move jumper links to match input  
voltage.  
Close and secure access door, or  
230 VOLTS  
460 VOLTS  
575 VOLTS  
1
Ref. S-174 973-B  
2
Tools Needed:  
3/8 in  
3/8 in  
Do not overtighten  
jumper link nuts.  
Ref. 800 103-A  
OM-2241 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-14. Connecting Input Power  
Y
Y
Installation must meet all National  
and Local Codes have only quali-  
fied persons make this installation.  
Disconnect and lockout/tagout in-  
put power before connecting input  
conductors from unit.  
3
Y
Y
Make input power connections to  
the welding power source first.  
= GND/PE Earth Ground  
9
Always connect green or green/  
yellow conductor to supply  
grounding terminal first, and never  
to a line terminal.  
8
See rating label on unit and check input  
voltage available at site.  
11  
1
Input Power Conductors (Customer  
Supplied Cord)  
10  
Select size and length of conductors using  
Section 3-12. Conductors must comply  
with national, state, and local electrical  
codes. If applicable, use lugs of proper  
amperagecapacity and correct hole size.  
2
4
7
Welding Power Source Input Power  
Connections  
2
Strain Relief  
Route conductors (cord) through strain re-  
lief and tighten screws.  
1
3
4
Machine Grounding Terminal  
Green Or Green/Yellow Grounding  
Conductor  
IMPORTANT  
5
Reed Switch (Ground Current  
Sensor) (Optional)  
3
6
Input Contactor  
Connect green or green/yellow grounding  
conductor to welding power source  
groundingterminal first. If unit is equipped  
with optional ground current sensor, route  
groundingconductor through reed switch  
two times and connect to grounding termi-  
nal.  
L1 (U)  
L2 (V)  
L3 (W)  
7
4
6
Welding Power Source Line  
Terminals  
7
Input Conductors L1 (U), L2 (V) And  
L3 (W)  
5
4
3
Connect input conductors L1 (U), L2 (V)  
and L3 (W) to welding power source line  
terminals.  
=
GND/ PE Earth Ground  
Close and secure access door on welding  
power source.  
Disconnect Device Input Power Con-  
nections  
8
Disconnect Device (switch shown in  
OFF position)  
9
Disconnect Device (Supply)  
Grounding Terminal  
Connect green or green/yellow grounding  
conductor to disconnect device grounding  
terminal first.  
Tools Needed:  
3/8 in  
3/8 in  
10 Disconnect Device Line Terminals  
Connect input conductors L1 (U), L2 (V)  
And L3 (W) to disconnect device line  
terminals.  
11 Over-Current Protection  
Select type and size of over-current  
protection using Section 3-12 (fused dis-  
connect switch shown).  
Close and secure door on line disconnect  
device. Remove lockout/tagout device,  
and place switch in the On position.  
800 103-C / Ref. 801 116-A  
OM-2241 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 4 OPERATION  
4-1. Controls  
1
2
3
4
209 383  
1
2
Voltage Meter  
Amperage Meter  
3
4
Power Switch With Indicator Light  
High Temperature Shutdown Light  
Y
Y
Weld output studs are energized by  
controls on the wirefeeder.  
Turn Off power before connecting re-  
mote device.  
Voltmeter and ammeter display actual output  
voltage and amperage.  
SECTION 5 MAINTENANCE & TROUBLESHOOTING  
5-1. Routine Maintenance  
Y
Disconnectinput power before maintaining.  
3 Months  
Clean and  
tighten weld  
terminals.  
Repair or  
replace  
cracked  
weld  
Replace  
unreadable  
labels.  
cable.  
6 Months  
Blow out or vacuum inside.  
During heavy service, clean  
monthly  
Or  
OM-2241 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-2. Fuse F1  
Y
Disconnect input power be-  
fore opening rear access  
door.  
1
2
Fuse Holder Cover  
Fuse F1 (See Parts List For  
Rating)  
Fuse F1 protects control transform-  
er from overload. If F1 opens, weld  
output and fan motor stops. Re-  
place F1.  
Close and secure access door.  
2
1
Tools Needed:  
3/8 in  
Turn  
Turn  
Pull Out And Replace Fuse  
(Install Flat End Of Fuse Into Cover)  
Ref. 800 101-C  
5-3. Short Circuit Shutdown  
When contact tip is shorted and sticks to workpiece, the unit output falls to a safe operating level. To resume operation,  
release gun trigger, turn Off unit, and remove contact tip from workpiece. Check contact tip and replace if damaged.  
Turn On unit to continue operation.  
OM-2241 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-4. Troubleshooting Table  
Trouble  
Remedy  
No weld output; unit completely  
inoperative.  
Place line disconnect switch in On position (see Section 3-14).  
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 3-14).  
Check for proper input power connections (see Section 3-14).  
Check for proper jumper link position (see Section 3-14).  
No weld output; Power switch pilot light Check, repair, or replace feeder (see wire feeder Owner’s Manual).  
on; fan on.  
Have Factory Authorized Service Agent check control board PC1.  
Unit provides only maximum or mini-  
mum weld output.  
Have Factory Authorized Service Agent check control board PC1.  
Erratic or improper weld output.  
Clean and tighten all weld connections.  
Check wire feeder installation according to Owner’s Manual.  
Have Factory Authorized Service Agent check control board PC1 and/or SCR in main rectifier.  
No 115 volts ac output at duplex  
receptacle or Remote 14 receptacle.  
No 24 volts ac output at Remote 14 re- Reset supplementary protector CB2 (see Section 3-7).  
ceptacle.  
Fan not operating.  
Check for and remove anything blocking fan movement.  
Have Factory Authorized Service Agent check fan motor.  
OM-2241 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 6 ELECTRICAL DIAGRAM  
218 521-A  
Figure 6-1. Circuit Diagram  
OM-2241 Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Notes  
OM-2241 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 PARTS LIST  
. Hardware is common and not  
available unless listed.  
803 388-B  
Figure 7-1 Main Assembly  
OM-2241 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 7-1 Main Assembly  
. . . 1 . . . . . . . . . . . . +179 430 . . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 2 . . . . . . . . . . . . . 179 429 . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . 209 104 . . BAFFLE, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 4 . . . . . . . . . . . . . 162 816 . . CHANNEL, upright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 5 . . . . . . . . . . . . . 162 820 . . BAR, mtg lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 6 . . . . . . . . . . . . . 177 279 . . GASKET, lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . 162 830 . . LIFT EYE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . 604 536 . . SCREW, .312-18 x 1.75 hexhd-pln gr 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 9 . . . . . Z1 . . . . 209 807 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . HD1 . . . . 168 829 . . TRANSDUCER, current 1000A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG14 . . 115 094 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . 173 605 . . BRACKET, mtg contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . C21-23 . . 163 906 . . CAPACITOR, 50 and 60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 13 . . . . . T2 . . . . 159 042 . . TRANSFORMER, control 50VA 24V 230/460/575 (60Hz) . . . . . . . . . . . . . . 1  
. . . 14 . . . . TE1 . . . . 159 244 . . PRIMARY BOX, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . . . . . . 601 835 . . . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
. . . 16 . . . . . . . . . . . . . 038 887 . . . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
. . . . . . . . . . . . . . . . . . . 010 913 . . WASHER, flat .218 ID brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
. . . . . . . . . . . . . . . . . . . 601 835 . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
. . . . . . . . . . . . . . . . . . . 038 618 . . LINK, jumper term bd pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
. . . 17 . . . . . . . . . . . . . 159 034 . . HOLDER, fuse mintr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . . F1 . . . *156 065 . . FUSE, crtg .5A 600V time delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . . . . . . . . . Fig 7-4 . . PANEL, rear w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . W . . . . . 160 793 . . CONTACTOR, def prp 60A 3P 24VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . CR4 . . 140 750 . . SWITCH, reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . 217 136 . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 23 . . . . . . . . . . . . . 163 533 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . C1 . . . . 221 925 . . CAPACITOR ASSEMBLY, (includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . . . . . . . . . . 163 535 . . . . CAPACITOR, elctlt 16000uf 60VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . 26 . . . . . . . . . . . . . 182 660 . . . . BUS BAR, mtg capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 27 . . . . . R6 . . . . 140 002 . . . . RESISTOR, WW fxd 10W 500 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 28 . . . . . . . . . . . . . 162 817 . . . . BUS BAR, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 29 . . . . . T1 . . . . 218 407 . . TRANSFORMER, pwr main 230/460/575 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . TP1,2 . . . 175 405 . . . . THERMOSTAT, NC (Included w/T1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . PLG13 . . 218 413 . . HOUSING, plug pin/skt (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . RC13 . . . 218 408 . . HOUSING, plug pin/skt (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 32 . . . . . . . . . . . . . 161 294 . . BRACKET, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 33 . . . . . . . . . . . . . . Fig 7-2 . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 34 . . . . SR1 . . . . 210 172 . . RECTIFIER, si diode (Fig 7-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Part of Option 195 048 Ground Current Sensor  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
*Recommended Spare Parts.  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-2241 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
. Hardware is common and not  
available unless listed.  
7
4
5
6
2
1
3
8
8
25  
9
25  
9
9
10  
25  
26  
21  
17  
16  
22  
24  
13  
11  
18  
12  
23  
19  
27  
14  
15  
20  
803 389-C  
Figure 7-2 Panel, Front w/Components  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
. . . 1 . . . . . . . . . . . . . 159 863 . . ELECTRONICS BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . PC1 . . . . 209 627 . . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG1 . . . 158 720 . . CONNECTOR & SOCKETS  
. . . . . . . . . PLG3 . . . 115 094 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG4 . . . 162 382 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG2 . . . 115 091 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . CR5 . . . . 006 393 . . RELAY, encl 24VAC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . CB1,2 . . . 093 995 . . SUPPLEMENTARY PROTECTOR, man reset 1P 15A 250VAC . . . . . . . . . 2  
. . . 5 . . . . RC9 . . . . 604 176 . . RECEPTACLE, str dx grd 2P3W 15A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . 210 281 . . CONNECTOR/CAPACITOR, w/leads (includes) . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . RC8 . . . . 143 976 . . . . RCPT w/ SCKTS (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . C3,6,13,14 . 097 749 . . . . CAPACITOR, cer disc .05 UF 500 VDC strip . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 7 . . . . . . . . . . . . . 204 143 . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . POS . . . 181 245 . . TERMINAL, pwr output red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 9 . . . C2,4,5 . . . 128 750 . . CAPACITOR, cer disc .1uf 500VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 10 . . . . . . . . . . . . . 161 303 . . SPRING, cprsn .600 OD x .072 wire x 1.500 lg . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 11 . . . . NEG . . . 181 246 . . TERMINAL, pwr output black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . . . . . . . . . 209 573 . . PLATE, control lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . . . . . . . . . 217 865 . . LABEL, warning electric shock and reduced air . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . . . . . . . +172 587 . . COVER, stud output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . . . . . . 160 935 . . CLIP, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 16 . . . . . . . . . . . . . 601 835 . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 17 . . . . . . . . . . . . . 038 887 . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . . . . . . . . . . 209 382 . . PANEL, front upper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . S2 . . . . 159 039 . . SWITCH, rocker SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-2241 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 7-2 Panel, Front w/Components (Fig 7-1 Item 33) (continued)  
. . . . . . . . . PLG2 . . . 185 626 . . CONNECTOR, body 56 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . PL2 . . . . 159 522 . . LED, yellow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . 159 036 . . LENS, LED clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . 118 901 . . METER, amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . . . . . . . . . 118 902 . . METER, volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . . . . . . . . . . 010 381 . . CONNECTOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 26 . . . . . . . . . . . . . 228 672 . . LABEL, weld cable lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 27 . . . . . . . . . . . . . 227 980 . . LABEL, caution output terminal connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
. Hardware is common and not  
4
3
available unless listed.  
5
2
1
6
7
Figure 7-3 Rectifier, Si Diode SR1  
803 396-A  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
SR1  
175 070  
Figure 7-3 Rectifier, Si Diode (Fig 7-1 Item 34)  
. . . 1 . . . . C7-12 . . . . 048 420 . . CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . 2 . . . . . . . . . . . . . . . 177 316 . . HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 3 . . . . . . . . . . . . . . . 177 317 . . HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 4 . . . . . . . . . . . . . . . 166 667 . . CLAMP, thyristor rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 5 . . . . . TP3 . . . . . 185 679 . . THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . SCR1-6 . . . 148 091 . . THYRISTOR, SCR 865A 300V hockey puck . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . . . . . . . . PLG1 . . . . 158 720 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . . . 188 692 . . CLAMP, thyristor rectifier 4.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-2241 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3
4
. Hardware is common and not  
available unless listed.  
5
6
2
1
7
11  
8
10  
9
800 707-B  
Figure 7-4 Panel, Rear w/Components  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
. . . 1 . . . . . . . . . . . . . . . 173 283 . . CHAMBER, plenum 14 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . . . 180 165 . . BLADE, fan 14 in 3wg 28deg .375 bore CCW . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . . . 162 807 . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . . . . 168 343 . . HINGE, door primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 5 . . . . . . . . . . . . . . +162 818 . . DOOR, access primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . . . 217 733 . . LABEL, warning electric shock & input power (EN/FR) . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . . . 602 177 . . SCREW, set .250-20 x .250knrlpt sch stl . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 8 . . . . . . . . . . . . . . . 124 274 . . BRACKET, mtg fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . R3 . . . . . . 097 459 . . RESISTOR, WW fxd 375W 20 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . FM . . . . . 208 402 . . MOTOR, 1/12HP 230V 1550RPM 50/60Hz .83A . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . . . 010 467 . . CONNECTOR, clamp cable 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-2241 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Effective January 1, 2006  
(Equipment with a serial number preface of “LG” or newer)  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
Warranty Questions?  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to  
its original retail purchaser that new Miller equipment sold after  
the effective date of this limited warranty is free of defects in  
material and workmanship at the time it is shipped by Miller. THIS  
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE  
WARRANTIES OF MERCHANTABILITY AND FITNESS.  
*
Induction Heating Coils and Blankets, Cables, and  
Non-Electronic Controls  
APT & SAF Model Plasma Cutting Torches  
Remote Controls  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
*
*
*
*
*
*
Accessory (Kits)  
Replacement Parts (No labor)  
Spoolmate Spoolguns  
Canvas Covers  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to such  
defects in material or workmanship. Miller must be notified in  
writing within thirty (30) days of such defect or failure, at which  
time Miller will provide instructions on the warranty claim  
procedures to be followed.  
Your distributor also gives  
you ...  
Miller’s True Blue® Limited Warranty shall not apply to:  
Service  
1. Consumable components; such as contact tips,  
cutting nozzles, contactors, brushes, slip rings, relays  
or parts that fail due to normal wear. (Exception:  
brushes, slip rings, and relays are covered on Bobcat,  
Trailblazer, and Legend models.)  
You always get the fast,  
reliable response you  
need. Most replacement  
parts can be in your  
hands in 24 hours.  
Miller shall honor warranty claims on warranted equipment listed  
below in the event of such a failure within the warranty time  
periods. All warranty time periods start on the date that the  
equipment was delivered to the original retail purchaser, or one  
year after the equipment is sent to a North American distributor  
or eighteen months after the equipment is sent to an  
International distributor.  
2. Items furnished by Miller, but manufactured by others, such  
as engines or trade accessories. These items are covered  
by the manufacturer’s warranty, if any.  
Support  
Need fast answers to the  
tough welding questions?  
Contact your distributor.  
The expertise of the  
distributor and Miller is  
there to help you, every  
step of the way.  
3. Equipment that has been modified by any party other than  
Miller, or equipment that has been improperly installed,  
improperly operated or misused based upon industry  
standards, or equipment which has not had reasonable and  
necessary maintenance, or equipment which has been  
used for operation outside of the specifications for the  
equipment.  
1. 5 Years Parts — 3 Years Labor  
*
Original main power rectifiers  
2. 3 Years — Parts and Labor  
*
*
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Process Controllers  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Sources (Unless Otherwise Stated)  
Water Coolant Systems (Integrated)  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by the  
engine manufacturer.)  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND  
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS  
TRAINED AND EXPERIENCED IN THE USE AND  
MAINTENANCE OF WELDING EQUIPMENT.  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)  
replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the goods at  
customer’s risk and expense. Miller’s option of repair or  
replacement will be F.O.B., Factory at Appleton, Wisconsin, or  
F.O.B. at a Miller authorized service facility as determined by  
Miller. Therefore no compensation or reimbursement for  
transportation costs of any kind will be allowed.  
3. 1 Year — Parts and Labor Unless Specified  
*
Motor Driven Guns (w/exception of Spoolmate  
Spoolguns)  
Positioners and Controllers  
Automatic Motion Devices  
RFCS Foot Controls  
Induction Heating Power Sources, Coolers, and  
Electronic  
Controls/Recorders  
*
*
*
*
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR  
DIRECT,  
INDIRECT,  
SPECIAL,  
INCIDENTAL  
OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY  
OTHER LEGAL THEORY.  
*
*
*
*
*
*
*
*
*
*
Water Coolant Systems (Non-Integrated)  
Flowgauge and Flowmeter Regulators (No Labor)  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND  
Grids  
ANY  
IMPLIED  
WARRANTY,  
GUARANTY  
OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION  
OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,  
Spot Welders  
Load Banks  
Arc Stud Power Sources & Arc Stud Guns  
Racks  
Running Gear/Trailers  
Plasma Cutting Torches (except APT & SAF  
Models)  
Field Options  
INCLUDING  
ANY  
IMPLIED  
WARRANTY  
OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT  
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED  
BY MILLER.  
*
(NOTE: Field options are covered under True Blue®  
for the remaining warranty period of the product they  
are installed in, or for a minimum of one year —  
whichever is greater.)  
Bernard-Branded Mig Guns (No Labor)  
Weldcraft-Branded TIG Torches (No Labor)  
Subarc Wire Drive Assemblies  
Some states in the U.S.A. do not allow limitations of how long an  
implied warranty lasts, or the exclusion of incidental, indirect,  
special or consequential damages, so the above limitation or  
exclusion may not apply to you. This warranty provides specific  
legal rights, and other rights may be available, but may vary from  
state to state.  
*
*
*
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated herein,  
and to the extent that they may not be waived, the limitations and  
exclusions set out above may not apply. This Limited Warranty  
provides specific legal rights, and other rights may be available,  
4. 6 Months — Batteries  
5. 90 Days — Parts  
*
MIG Guns/TIG Torches and Subarc (SAW) Guns  
but may vary from province to province.  
miller_warr 200601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
For Service  
Contact a DISTRIBUTOR or SERVICE AGENCY near you.  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters −  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
To locate a Distributor or Service Agency visit  
www.MillerWelds.com  
Contact the Delivering Carrier to:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims, contact  
your distributor and/or equipment manufacturer’s  
Transportation Department.  
PRINTED IN USA  
© 2006 Miller Electric Mfg. Co.200601  
Download from Www.Somanuals.com. All Manuals Search And Download.  

NAD CD Player T550DVD User Manual
NETGEAR Switch GS105NA User Manual
OEM Systems Speaker RS 68 User Manual
Olympus Camera Lens 07 User Manual
Olympus Carrying Case MR 100 User Manual
OPTI UPS Power Supply Standby UPS System User Manual
Oster Hair Clippers 76110 78670 User Manual
Palm PDAs Smartphones SmartOffice Mobile User Manual
Panasonic Telephone KX NT700 User Manual
Panasonic Vacuum Cleaner MC UL675 User Manual