Operating and installation instructions
Ventilation System
DA 279-3
UV
To prevent accidents
and machine damage,
read these instructions
before installation or use.
M.-Nr. 05 853 690
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Main power switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Turning on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Turning off the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Turning the lighting on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Indirect lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Filter timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Checking the filter timers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Reprogramming the timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Cleaning the casing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Active charcoal filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Read these Operating Instructions carefully before installing or
using the Ventilation System.
This appliance is designed to vent
cooking smoke and odors only.
This appliance is intended for
residential use only. Use the
appliance only for its intended
purpose. The manufacturer cannot
be held responsible for damages
caused by improper use of the
hood.
Be certain your appliance is prop-
erly installed and grounded by a
qualified technician.
To guarantee the electrical safety of this
appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician. The manufacturer
can not be held responsible for
damages caused by the lack, or
inadequacy of, an effective grounding
system.
This appliance complies with current
safety requirements. Improper use of
the appliance can lead to personal
injury and material damage.
READ AND SAVE THESE
INSTRUCTIONS
Before connecting the appliance to
the power supply make sure that
the voltage and frequency listed on the
data plate correspond with the house-
hold electrical supply. This data must
correspond to prevent machine
damage. Consult a qualified electrician
if in doubt.
CAUTION
For General Ventilating Use Only.
Do Not Use To Exhaust Hazardous
Or Explosive Materials And Vapors.
Installation work and repairs should
only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and other work by unqualified
persons could be dangerous and the
manufacturer will not be held
responsible.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
This equipment is not designed for Use
maritime use or for use in mobile
installations such as caravans or air-
craft. However, under certain conditions
it may be possible for an installation in
these applications. Please contact the
nearest Miele dealer or the Miele Tech-
nical Service Department with specific
requirements.
Do not allow children to play with
or operate the appliance or its
controls. Supervise its use by the
elderly or infirm.
Be careful when preparing a
flambé beneath the hood.
Flames may be drawn up into the hood
by the suction or grease filters may
catch fire.
Before servicing or cleaning the
unit, switch power off at the service
panel and lock the service disconnect-
ing means to prevent power from being
switched on accidentally. When the
service disconnecting means can not
be locked, securely fasten a prominent
warning device, such as a tag, to the
service panel.
Never operate gas burners without
pots.
Do not leave cooking surfaces
unattended while in use. Over-
heated food, oil and grease can catch
fire.
Do not use the hood without the
grease filters in place.
Before discarding an old
appliance, unplug it from the
Clean the grease filters regularly.
Dirty filters are a fire hazard.
power supply and remove the power
cord and any doors to prevent hazards.
Do not use a steam cleaner to
clean the hood. Steam could
penetrate electrical components and
cause a short circuit.
In areas subject to infestation by
cockroaches or other pest, keep
the appliance and its surroundings
clean at all times. Any damage caused
by cockroaches or other pest will not
be covered under warranty.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
, WARNING - TO REDUCE
THE RISK OF A RANGE TOP
GREASE FIRE:
, WARNING
TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
Never leave surface units unat-
tended at high settings. Boilovers
cause smoking and greasy spillovers
may ignite. Heat oils slowly on low or
medium settings.
SMOTHER FLAMES with a close
fitting lid, cookie sheet, or metal
tray, then turn off the burner.
BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE
DEPARTMENT.
Always turn hood "ON" when cook-
ing at high heat or when cooking
flaming foods.
Clean ventilating fans frequently.
Grease should not be allowed to
accumulate on fan or filter.
NEVER PICK UP A FLAMING
PAN - You may be burned.
DO NOT USE WATER, including
wet dishcloths or towels - a violent
steam explosion will result.
Use proper pan size. Always use
cookware appropriate for the size
of the surface element.
Use an extinguisher
ONLY IF:
– You know you have a Class ABC
extinguisher, and you already know
how to operate it.
– The fire is small and contained in the
area where it started.
– The fire department is being called.
– You can fight the fire with your back
to an exit.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Installation
Never connect an exhaust hood to
an active chimney, dryer vent, vent
flue, or room ventilating ductwork. Seek
professional advice before connecting
an exhaust hood vent to an existing,
, WARNING
To reduce the risk of fire, only
use metal ductwork.
When installing the hood, follow the inactive chimney or vent flue.
recommended minimum safety
Ducted fans must always be
distances between a Miele cooktop and
vented outdoors.
the hood:
Make sure that the airflow in the
– 22" (55 cm) above electric cooktops,
room is sufficient for combustion
– 26" (65 cm) above gas cooktops,
– 26" (65 cm) above an open grill.
and exhausting of all non-electric heat-
ing appliances (water heaters, gas
cooktops, gas ovens, etc.), otherwise
backdrafts may occur. Follow the heat-
ing manufacturer’s guidelines and
safety standards or those published by
the National Fire Protection Association
(NFPA), or the American Society for
Heating, Refrigeration and Air
If local building codes require a greater
safety distance, follow their require-
ment.
For non-Miele cooking appliances
maintain the safety distances recom-
mended by the appliance manufacturer
in their installation and operating
instructions.
If there is more than one appliance
beneath the hood and they have differ-
ent minimum safety distances always
select the greater distance.
Conditioning Engineers (ASHRAE).
If in doubt, consult an experienced
professional.
Be careful not to damage hidden
electrical wiring or plumbing when
cutting or drilling into the wall or ceiling.
Do not use an extension cord to
connect the appliance to electricity.
Extension cords do not guarantee the
required safety of the appliance, (e.g.
danger of overheating).
Do not install this hood over
cooktops burning solid fuel.
Any fittings, sealant, or materials
used to install the ductwork must
be made of approved non-flammable
materials.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the appliance
a Chimney extension
b Chimney
n Grease filter button
The indicator next to the grease filter
button lights when the grease filters
need to be cleaned. This button is also
used:
c Canopy
– to reset the grease filter timer after
cleaning the grease filters (see
"Cleaning and Care").
d Indirect lighting
e Grease filter
– to show how long the grease filters
have been in use (see "Operation /
Filter timers").
f Overhead lighting
g Recirculation vent
h Main power switch
i Indirect lighting switch
j Light button
– to change the number of hours
counted by the grease filter timer
(see "Operation / Reprogramming the
filter timers").
o Charcoal filter button
The indicator next to the charcoal filter
button lights when the charcoal filter
needs to be replaced.
This button turns the light on and off
and also dims the light.
This button is also used:
The lighting can be used independently
of the fan.
– to reset the charcoal filter timer after
changing the filter (see "Cleaning
and care").
k On/Off button
– to show how long the charcoal filter
has been in use (see "Operation / Fil-
ter timers")
l Fan power selection
Four fan speed selection
– to change the number of hours
counted by the charcoal filter timer
(see "Operation / Reprogramming the
timers").
m Delayed shut down
This button activates the Delayed Shut
Down feature. The fan can be set to
turn off automatically after either 5 or 15
minutes.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Functional description
The hood offers two modes of opera-
tion:
Air extraction
Recirculation mode
The air is drawn in and cleaned by the
grease filters and directed outside.
Air is drawn through the grease filters
and an active charcoal filter. The fil-
tered air is then recirculated back into
the kitchen through a vent at the top of
the hood’s chimney.
The hood comes equipped with a
non-return flap. This flap automatically
closes when the hood is turned off so
that no exchange of outside air and
room air can occur. When the hood is
turned on, the air pressure of the ex-
haust fan automatically opens the flap
blowing the inside air and cooking
odors outside.
Before using the hood in
recirculation mode, ensure that the
active charcoal filter is in place, see
"Cleaning and care".
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Main power switch
Selecting the power level
^ Use the _ controls to select the
^ Press the main power switch to "I".
desired power level.
The fan and lighting are ready to use.
& =increases the fan speed
$ =decreases the fan speed
If the appliance is not going to be used
for a long period of time (e.g. while va-
cationing) it should be turned off at the
main power switch to "0".
Level "1" to "3" (green indicators) are
usually sufficient for normal cooking.
The next time it is turned on, the hood
will operate at the level previously used.
Intensive setting
Level "4" (yellow indicator) should be
used for a short period when frying or
cooking food with a strong aroma.
Turning on the fan
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
^ Press the On/Off button.
There will also be a slight decrease in
airflow for hoods operated in
recirculation mode due to the active
charcoal filter.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Delayed Shut Down
Turning off the fan
If odors or smoke remain in the kitchen
after cooking has been completed, the
Delayed Shut Down feature can be se-
lected to allow the hood to continue
running for either 5 or 15 minutes.
^ Press the On/Off button to turn the
fan off.
The indicator goes out.
Automatic Safety Shut Off
^ Press the Delayed Shut Down button
The fan will turn off automatically 10
hours after the last button was activated.
The lighting however will remain on.
while the fan is still running.
Press once = 5 minute delay
(left indicator lights)
Press twice = 15 minute delay
(right indicator lights)
^ Press the On/Off button to turn the
fan back on again.
To cancel the Delayed Shut Down fea-
ture press the button again.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Turning the lighting on/off
Indirect lighting
The overhead lighting can be turned
on and off independently of the fan.
^ Press the indirect lighting switch to
"I".
The indirect lighting can be turned on
when the main power switch is off.
^ Press the light button briefly to turn
on the lighting.
The light button indicator illuminates.
^ Press the light button briefly again to
turn off the lighting.
The light button indicator will go out.
Dimming the lighting
The brightness of the lighting can be
adjusted.
^ While the lighting is turned on, press
the light button.
The lighting will dim until the button is
released.
^ If the button is pressed again, the
lighting will brighten until the button is
released.
If the button is pressed continuously,
the light will cycle between bright and
dark.
^ Press the light button again to turn off
the lighting.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Filter timers
Checking the filter timers
To check the percentage of time al-
ready used:
Grease filters
A timer monitors the hours of fan opera-
tion. The indicator for the grease filter
will light after 30 hours of operation. The
grease filters must then be cleaned.
^ Press the On/Off button to turn the
fan on.
After the grease filters have been
cleaned and put in place, the grease fil-
ter timer must be reset.
^ Press the grease or charcoal filter
button.
^ To do this, press the grease filter but-
ton for about 3 seconds.
The indicator will go out.
Charcoal filter
The number of flashing _ indicators
show the percentage of programmed
hours that have been used.
Recirculation mode only
The timer for the charcoal filter is not
preset. Please program this timer, see
"Operation/Reprogramming the char-
coal filter timer".
1 indicator = less than 25 %
2 indicators = less than 50 %
3 indicators = less than 75 %
4 indicators = less than 100 %
This information will remain stored in
memory in the event of a power failure.
The charcoal filter indicator will light
once the selected time has elapsed.
The charcoal filter must then be re-
placed and the charcoal filter timer re-
set.
^ To do this, press the charcoal filter
button for about 3 seconds.
The indicator will go out.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Reprogramming the timers
The indicator for the grease filter and
one of the _ indicators will flash.
The grease filter timer is preset to 30
hours. This time can be lengthened or
shortened to 20, 30, 40 or 50 hours.
– A time of 20 hours should be pro-
grammed in kitchens with frequent
pan or deep frying.
The lit indicator shows the programmed
time:
– A time of 20 hours should also be
programmed if the kitchen is only
used occasionally to prevent grease
which has accumulated over a long
period of time from hardening on the
filters making cleaning more difficult.
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours
^ Use the $ or & button to select the
desired time.
Reprogramming the grease filter
timer
^ Store the selection by pressing the
grease filter button.
^ Press the On/Off button to turn off the
fan.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
Press the Delayed Shut Down and
grease filter buttons at the same time.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Reprogramming the charcoal filter
timer
The indicator for the charcoal filter and
one of the _ indicators will flash.
The active charcoal filter can only be
used in recirculation mode and can not
be used to exhaust fumes.
The charcoal filter timer is not not pre-
set.
The lit indicator shows the programmed
time:
Before using the hood in recirculation
mode, the charcoal filter timer must be
programmed.
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours
^ Use the $ or & button to select the
desired time.
^ Turn off the fan using the On/Off but-
ton.
^ Store the selection by pressing the
charcoal filter button.
^ Press the Delayed Shut Down and
charcoal filter buttons at the same
time.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Stainless steel
Before cleaning or servicing the
hood, disconnect it from the power
supply by either removing the fuse,
unplugging it from the outlet or man-
ually "tripping" the circuit breaker.
Stainless steel surfaces can be cleaned
using a non-abrasive stainless steel
cleaner.
To help prevent resoiling, a conditioner
for stainless steel can also be used.
Apply sparingly with even pressure.
Cleaning the casing
Warning: Never use abrasive clean-
ers, scouring pads, steel wool or
caustic (oven) cleaners on the hood.
They will damage the surface.
Stainless steel colored controls
These controls may become discol-
ored or damaged if not cleaned reg-
ularly.
Do not use a stainless steel cleaner
on these controls.
^ All external surfaces and controls can
be cleaned with warm water and liq-
uid dish soap applied with a soft
sponge.
^ Wipe dry using a soft cloth.
Do not use too much water when
cleaning the controls. Water could
penetrate into the electronics and
cause damage.
^ Glass surfaces can be cleaned using
glass cleaner.
Avoid:
– cleaning agents containing soda, ac-
ids or chlorides,
– abrasive cleaning agents e.g. pow-
der or cream cleansers,
– abrasive sponges, e.g. pot scourers
or sponges which have been previ-
ously used with abrasive cleaning
agents.
These will damage the surface.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Grease filters
^ Clean the filters
- by hand: use a scrub brush in
warm water with a mild detergent.
- in a dishwasher: place the filters
vertically in the lower basket, making
sure that the spray arm is not
blocked.
The reusable metal grease filters re-
move solid particles from the vented
kitchen air (grease, dust, etc).
The grease filters should be cleaned
every 3 - 4 weeks or whenever the
grease filter indicator lights.
Depending on the detergent, clean-
ing the grease filters in a dishwasher
may cause permanent discoloration
of the filter surface. Performance of
the filter will not be affected by this
discoloration.
A dirty filter is a fire hazard.
^ After cleaning, the filters can be
placed on a towel to air dry.
^ While the filters are removed, clean
any dirt or grease from the filter cas-
ing to prevent the risk of fire.
When putting the grease filters back
make sure that the locking clips are vis-
ible facing the cooking surface.
^ To remove the grease filters press the
locking clips in towards the middle of
the filter. Support grease filter so that
it does not fall on to the cooktop.
If the filters are incorrectly installed, in-
sert a small screwdriver into the slit
along its edge to disengage it from the
casing.
^ After returning the grease filters,
press the grease filter button for 3
seconds to reset the timer. The indi-
cator light will go out.
^ If the grease filters are cleaned be-
fore the grease filter timer has
reached its maximum, the grease fil-
ter button should be pressed for
6 seconds to reset the counter to
zero.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Active charcoal filter
In recirculation mode an active char-
coal filter must be used in addition to
the grease filters. The charcoal filter is
designed to absorb cooking odors.
The active charcoal filter will be placed
in the canopy above the grease filters.
Replacement active charcoal filters
(part # 03 284 680) can be ordered
from the Miele Technical Service
Department.
USA 1-800-999-1360
CDN 1-800-565-6435
^ Insert the charcoal filter.
Before using:
^ Program the charcoal filter timer, see
"Operation/Reprogramming the char-
coal filter timer".
^ The grease filters must be removed
to access the active charcoal filter.
See "Cleaning and Care".
^ Two support angles must be installed
(see Installation manual to support
the charcoal filter.)
Replace the active charcoal filter when
the charcoal filter indicator lights. Re-
place the filter at least every 6 months
or when it no longer absorbs odors effi-
ciently.
The active charcoal filter comes
boxed with 2 filters.
For best results, tightly seal the bag
containing the remaining filter.
^ After replacing the charcoal filter,
press and hold the charcoal filter but-
ton for about 3 seconds to reset the
charcoal filter timer.
The indicator light will go out.
^ If the charcoal filter is replaced be-
fore the timer has reached its maxi-
mum, the charcoal filter button
should be pressed for 6 seconds to
reset the counter to zero.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Changing the light bulb
Before changing the light bulbs, dis-
connect the hood from the power
supply by either removing the fuse,
unplugging it, or manually "tripping"
the circuit breaker.
When in use halogen bulbs become
extremely hot, and they can burn
your hands. Do not attempt to
change the bulbs until they have
had sufficient time to cool down.
^ To change the halogen bulb first re-
move the lamp cover, a.
^ Pull the bulb, b, out of its socket and
replace with a new one.
Do not touch the bulb surface. Fin-
gerprints or body oils deposited on
the bulb will decrease the life of the
bulb.
Please follow the bulb manufac-
turer’s instructions.
^ Return the lamp cover, a.
Never use the lighting without the
lamp cover, a, in place. The glass is
specially made to filter harmful light
rays.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
After Sales Service
In the event of a fault which you cannot
correct yourself please contact:
– Your Miele Dealer
or
– The Miele Technical Service
Department
USA 1-800-999-1360
CDN 1-800-565-6435
When contacting the Technical Service
Department, please quote the model
and serial number of your appliance.
These are shown on the data plate
which is visible when the grease filter is
removed.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Installation instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Caring for the environment
Disposal of packing material
Disposal of an old appliance
The cardboard box and packing
materials protect the appliance during
shipping. They have been designed to
be biodegradable and recyclable.
Please recycle.
Old appliances may contain materials
that can be recycled. Please contact
your local recycling authority about the
possibility of recycling these materials.
Before discarding an old hood, un-
plug it from the outlet and cut off its
power cord to prevent hazards.
Ensure that any plastic wrappings,
bags etc. are disposed of safely and
kept out of the reach of children.
Danger of suffocation!
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation accessories
a
2 recirculation vents
(recirculation mode only)
b
2 protective shields
8 large headed screws 5 x 40 mm
for securing the retaining plates and the
canopy.
prevent scratches to the chimney dur-
ing installation.
c
1 diverter
(S8 wall anchors included in the pack-
aging are not for use in USA / CDN.)
(recirculation mode only)
d
1 flex hose for connecting the di-
verter to the exhaust connection.
e
2 hose clips for securing the
ducting.
2 M 6 locking nuts for securing the
motor assembly.
f
1 reducing collar
for use with 5" (125 mm) exhaust
ducting.
g
1 non-return flap for vented air
2 screws 3.9 x 7.5 mm for securing the
chimney.
extraction only.
h
Upper retaining plate secures the
chimney extension.
i
Middle retaining plate for addi-
tional stability of the chimney.
1 allen wrench
for adjusting the unit height
j
Lower retaining plate secures the
canopy and motor assembly.
k
2 support angles to secure the
active charcoal filter in recirculation
mode.
1 lever for dismantling the chimney
Caution: During the installation pro-
cess, please be careful of sharp
edges that can cause harm.
Installation instruction sheet
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Plywood backing
^ Find the studs to the left and right of
the mounting location by tapping the
wall or using a stud finder.
The majority of the weight of the in-
stalled ventilation system will be
supported by the lower retaining
plate. It must be firmly attached to
the stud framing behind the drywall.
If studs are not available in the re-
quired locations, a plywood backing
(min. 1/2" (13 mm) thick) spanning at
least two studs must be installed.
Failure to adequately support the
weight as stated may result in the
ventilation system falling off the wall,
causing personal injury and property
damage.
^ Mark a vertical cutting line along the
center of each stud.
Be careful not to damage any wiring
or plumbing that may be located be-
hind the wall. Make sure that the
power supply to the area where this
installation is being performed has
been turned off at the breaker panel
before cutting into the wall.
^ Remove the drywall between the cut-
ting lines and replace it with plywood
of a matching thickness (min. 1/2"
(13 mm) thick). Tape the joints and
refinish the wall.
(If plywood backing is not needed, pro-
ceed to the included installation sheet.)
To install a plywood backing
^ Proceed to the included installation
sheet to complete the installation.
^ Determine and mark the location of
the retaining plate for the canopy as
outlined on the installation sheet.
^ Make a cutting line 3" (76 mm) above
and 3" (76 mm) below the outline of
the retaining plate.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical data
Important
All electrical work should be per-
formed by a qualified electrician in
strict accordance with national and
local safety regulations.
The hood comes equippped with a 5 ft
(1.5 m) power cord with a NEMA 5-15
molded plug for connection to a
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer can
not be held responsible for unautho-
rized work.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
120 VAC, 60 Hz, 15 A power outlet.
Maximum load . . . . . . . . . . . . . . 420 W
Overhead lighting . . . . . . . . . . 3 x 20 W
Indirect lighting . . . . . . . . . . . . . . . 10 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit rating. . . . . . . . . . . . . . . . . . 15 A
Verify that the voltage, load and circuit
rating information found on the data
plate (located behind the grease fil-
ters), match the household electrical
supply before installing the hood.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or call Miele’s Tech-
nical Service Department.
USA 1-800-999-1360
CDN 1-800-565-6435
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
Standard unit height H:
Do not install this exhaust hood over
cooktops burning solid fuel.
DA 279
Air Extraction. . . . . . . . . 28 3/4 - 39 15/16"
. . . . . . . . . . . . . . . . . . (730 - 1015 mm)
When installing the hood, make sure
that the following minimum dis-
tance (S) between the top of a Miele
cooking surface and the bottom of
the hood is:
- 22" (55 cm) above electric cooktops
- 26" (65 cm) above gas cooktops
- 26" (65 cm) above an open grill
Recirculation . . . . . . . . . 32 5/16 - 43 5/16"
. . . . . . . . . . . . . . . . . . (820 - 1100 mm)
To fit the chimney, distance A between
the top of the chimney and the ceiling
must be at least 7/8" (20 mm).
Cut out area in wall or ceiling for
entrance of 6" (150 mm)
ductwork or 5" (125 mm)
For non-Miele cooking appliances
maintain the safety distances recom-
mended by the cooktop manufac-
turer in their installation and operat-
ing instructions.
ductwork with a reducing collar.
If there is more than one appliance
beneath the hood and they have dif-
ferent minimum safety distances al-
ways select the greater distance.
See "Important Safety Instructions"
for further information.
26" (65 cm) is recommended for all in-
stallations to allow for optimum work
space under the hood.
Read the entire installation procedure
and determine height (S) before begin-
ning the installation. Installations differ
depending on the model and venting
method. If the hood is fitted flush to the
ceiling make sure that the remaining
distance to the ceiling is not greater or
less than appliance height H.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation instruction
Dismantling
See the enclosed installation instruction If the hood needs to be disassembled,
sheet.
follow the instructions on the installation
sheet in reverse order.
Please read the "Important Safety In-
structions" and Installation instructions
before installing this hood.
A lever is enclosed for easier removal
of the chimney extension.
Protective film
The casing is covered by a protective
film to prevent scratches during trans-
port.
Peel off the film before installing the
casing parts.
^ After removing the screws from the
chimney, slide the lever between
chimney and chimney extension and
gently apply pressure to ease the
chimney from its hooks.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Exhaust ducting and connections
,WARNING
– The ducting should be as short and
straight as possible, and the number
of sharp bends should be minimized.
Danger of toxic fumes.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
– For most efficient air extraction, the
diameter of the ductwork should not
be less than 6" (150 mm). Use of flat
ducts also reduces the air extraction
efficiency.
The exhaust gases extracted by
the hood should be vented out-
side of the building only.
– Noise levels of the hood will increase
if flat ducts or round ducts of less
than 6" (150 mm) in diameter are
used.
Do not terminate the exhaust
ducts in attics, garages,
crawlspaces, etc.
– Use smooth or flexible pipes made
from approved non-flammable mate-
rials for exhaust ducting.
To reduce the risk of fire, only use
metal ductwork.
– Where the ductwork is horizontal, it
must slope away from the hood at
least 1/8" per foot (1cm per meter) to
prevent condensation dripping into
the appliance.
Please read and follow the
"IMPORTANT SAFETY
INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building
codes when installing the hood.
– If the exhaust is ducted through an
outside wall, a Miele Telescopic Wall
Vent can be used.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Condensate trap
Important:
If the ductwork runs through rooms,
ceilings, garages, etc. where tempera-
ture variations exist, it may need to be
insulated to reduce condensation. In
some cases, a condensate trap may
also be required to collect and evapo-
rate any condensate which may occur.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.
– If the exhaust is ducted into an inac-
tive flue, the air must be expelled
parallel to the flow direction of the
flue.
Never connect an exhaust hood to
an active chimney, dryer vent, vent
flue, or room venting ductwork. Seek
professional advice before connect-
ing an exhaust hood vent to an exist-
ing, inactive chimney or vent flue.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Alteration rights reserved / 5002
M.-Nr. 05 853 690 / V00
This bio-friendly paper is bleached without the use of chlorine.
Download from Www.Somanuals.com. All Manuals Search And Download.
|