Oki Voice Over IP Telephony Adapter
User’s Guide
Version 1.2
Oki Electric Industry Co., Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Warning!
This document contains information regarding the safe use of the Oki
VoIP-TA unit. Carefully observe and comply with all safety precautions.
Download from Www.Somanuals.com. All Manuals Search And Download.
© 1999-2000, Oki Electric Industry Co., Ltd. All rights reserved.
The VoIP-TA Internet Telephony Adapter and the Maintenance Console
Software are products of Oki Electric Industry Co. Ltd.
The right to reproduce this manual and/or the Maintenance Console Software is
restricted by the Copyright Act.
No part of this document may be copied, reproduced, stored on a retrieval
system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, in whole or in part, without the written
permission of Oki Electric Industry Co. Ltd.
Information in this document is subject to change without notice.
The contents of this document and the Maintenance Console Software have
been prepared with the utmost care. However, if you notice an irregularity,
please contact an authorized sales agent.
Oki Electric Industry Co. Ltd., assumes no responsibility with regard to
consequences resulting from the use of the Maintenance Console Software and/or
the contents and interpretation of the information contained in this manual.
Ethernet is a registered trademark of Xerox Corporation.
MS-DOS and Windows are registered trademarks of Microsoft Corporation.
Other companies and product names mentioned in this manual my be the
trademarks or the registered trademarks of their respective companies. Oki
Electric Industry Co. Ltd., neither endorses or recommends third-party
products mentioned herein nor assumes responsibility with regard to the use
or performance of these products.
Download from Www.Somanuals.com. All Manuals Search And Download.
ii
Contents
Important Safety Instructions
iv
Introduction
vi
1
I
Outline
The VoIP-TA
Features
1
1
Front panel
LEDs
2
2
Back panel
3
Connectors
3
II
Installation
Connections
5
5
Cautions
7
III
Placing Calls
Via an IP network
General operation
8
8
8
Services
9
Third party incoming call during another call
9
End-to-end service using DTMF signaling
Call transfer during a telephone Call
10
10
Absent service
Details of services
12
13
Using both a PSTN line and the IP network
Using the IP network only 16
13
IV Troubleshooting
Specifications
Important Equipment Information
Warranty and Service 20
17
V
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
iii
Important Safety Instructions
When handling or using the VoIP-TA unit, the following safety precautions should
be observed to prevent injury and/or damage to the unit. Use of this equipment in
a manner other than that specified in this and other VoIP-TA documents will void
the product warranty and may result in damage, serious injury or death.
WARNING Incorrect use by neglecting the following instructions
may cause fire, electric shock, unit failure, resulting in
damage, serious injury or death.
• Do not connect a commercial power supply circuit, analogue, digital
(ISDN) or PBX digital telephone line to the LAN or PC port.
• Do not use with power supply voltages other than those specified.
• Do not insert or drop metal objects into any of the openings.
• Do not disassemble or modify this product in any way.
• Do not place any vases, cups, cosmetics, chemicals, pots or any other
containers containing liquids or small metal objects, near the product.
Spillages into the product may cause fire, electric shock or unit failure.
• Do not try to connect or disconnect the power plug with wet hands.
• Insert the power plug fully and securely into the power outlet. To avoid
electric shock, do not use a plug that exposes the terminals when
inserted.
• Avoid star connections as fire or overheating may result.
• Do not put heavy objects on the AC adapter cord or expose it to
excessive heat.
• Do not pull the cord or allow it to overheat as it may be damaged and
could cause fire or electric shock.
• If lightning strikes a neighboring area, stop operating the product by
disconnecting the AC plug (by grasping the power plug, not the cord)
from the power supply outlet.
• Always ground the product properly.
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
iv
• Do not use AC adapters other than those specified or supplied.
• If liquid enters the unit, immediately disconnect the power plug (by
grasping the power plug, not the cord) from the power outlet and
contact an authorized sales agent or service provider. Continued use
may result in fire or electric shock.
• If smoke or fumes are emitted from the unit, immediately disconnect
the AC plug (by grasping the power plug, not the cord). When smoke
emissions cease, contact a sales agent or service office for repair.
Continued use may cause fire, electric shock or unit failure.
• Use only authorized sales agents or service offices for internal
inspection or repair.
CAUTION Incorrect use by neglecting the following instructions
may cause fire, electric shock, unit failure resulting in
injury or damage.
• Avoid oily, humid or dusty locations, such as on a kitchen table or near
a humidifier.
• Do not place the unit on unstable or inclined surfaces as the unit may fall.
• Avoid locations exposed to direct sunlight or moisture as internal
overheating may occur causing fire or unit failure.
• Wipe away with a dry cloth any water droplets that may be on the
surface of the unit. Water intrusion may cause fire or unit failure.
• Do not cover up the vent holes of the VoIP-TA. If covered, internal
overheating may result causing fire or unit failure.
• Do not unplug the AC power plug by pulling on the cord. Always grasp
the plug portion when disconnecting the AC power plug.
• Disconnect the AC power cord and other connectors when moving the
VoIP-TA.
• For safety, disconnect the AC plug from the power supply outlet (by
grasping the power plug, not the cord) before starting maintenance.
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
v
Introduction
Welcome to the world of Oki Internet telephony…
The Oki voice over IP (Internet Protocol) telephony adapter, VoIP-TA, is a
self-contained H.323 version 2 compliant communications device that
allows organizations to route both voice and facsimile communications
over any TCP/IP network.
The VoIP-TA is designed to provide a service that is virtually
indistinguishable from that of conventional telephone and facsimile
services.
Use this guide to familiarize yourself with the VoIP-TA. Should you need
to handle the equipment, pay special attention to the procedures and
safety precautions contained in this guide.
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
vi
I
Outline
The VoIP-TA
The VoIP-TA is a one-channel Internet telephony adapter that provides
Internet telephony services conforming to industry standard H.323
version 2 specifications. It can be connected to a conventional analogue
telephone or G3 facsimile machine.
Once installed, VoIP-TA units use the Internet Protocol (IP) network to
bridge the distance between units at a fraction of the cost associated with
conventional telephony methods.
* Gatekeeper is necessary when more than 100 IP addresses are to
be used.
Features
•
Compact size and one-channel Internet telephony adapter.
•
•
•
Automatic telephone routing by specified telephone numbers.
Smooth and natural telephone calls by optimizing the voice buffer.
Supports Dynamic Host Configuration Protocol (DHCP manual
allocation) for local IP addresses.
•
•
•
Conforms to the ITU-T recommended H.323 version 2 specifications.
Supplies real-time Internet facsimile communication.
Uses high quality voice compression technology.
The Public Switched Telephone Network (PSTN) is supported by VoIP-TA version
1.2 and later. The version number is clearly marked on the bottom of the unit. Please
contact your network manager or authorized sales agent or service office if in doubt,
to avoid incorrect use.
Note
Download from Www.Somanuals.com. All Manuals Search And Download.
Outline
1
Front panel
LEDs
POWER
ALARM
Indicates power ON when lit.
Green lamp.
Indicates alarmed condition
detected in unit when lit.
Red lamp. (see table 1 p. 4)
LINE
LAN
Indicates PSTN line is used
during operation when lit.
Green lamp.
Indicates LAN link is
established and operating
normally when lit . When
blinking, data is being sent.
Green lamp.
PC
Indicates link is established
and operating normally when
lit. When blinking, data is
being received.
Green lamp.
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Outline
Back panel
Connectors
TEL
Connects a conventional
analogue telephone or G3
facsimile machine. Dial signal:
DTMF signaling only.
LINE
PC*
Connects to an analogue
public telephone line.
Connects to a PC via a straight
cable (category 3 or higher).
Not for Maintenance Console
Software. Use category 5 for
100BASE-TX.
LAN*
Connects to LAN via a cross
cable (category 3 or higher).
Use a straight cable for HUB
connection. Use category 5 for
100BASE-TX.
CONSOLE Connects to a PC (serial port)
for data setup. Use an RS232C
connector cable (straight).
FG
Terminal strip for frame
ground.
DC IN 12V Connects an AC adapter.
The communication performances of the LAN and PC ports are always the same and
VoIP-TA conforms to the lower of the two. When either the PC or LAN port is 10
BASE-T, both ports are set to 10 BASE-T communication. If a PC is connected to the
PC port during a call, the call may be interrupted for approximately one second.
Please avoid such usage.
*
Download from Www.Somanuals.com. All Manuals Search And Download.
Outline
3
Table 1
Mode
ALARM-LED LINE-LED
Status
Initialization
Blinks
(1 sec.
intervals)
OFF
With Gatekeeper:
The system will wait for
LAN link to be established
while Gatekeeper registers
the VoIP-TA.
Without Gatekeeper:
The system will wait for a
LAN link to be established.
Operation
OFF
OFF
OFF
OFF
ON
Standby
The telephone line is busy.
Blinks
(1 sec.
When using both IP and
PSTN:
intervals)
The PSTN is on hold during
VoIP calls.
When using IP network only:
The absent service is
setting up.
Blinks
(0.5 sec.
intervals)
The handset is off the hook
and the howler tone has
already stopped.
OFF
Setup
Blinks
(0.2 sec.
intervals)
Blinks
(0.2 sec.
intervals)
Normal operation is not
available in the Setup
mode.
Installation
Blinks
(0.2 sec.
intervals)
Blinks
(1 sec.
intervals)
Normal operation is not
available in the Install
mode. The LED lamp may
blink irregularly during the
program installation.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Outline
II
Installation
Place the main unit in a vertical position as placing it horizontally could
shorten the life of the unit.
Connections
The following illustration shows where equipment should be connected
to the ports at the rear of the VoIP-TA unit.
Analogue telephone or G3 facsimile equipment
Connect an analogue telephone or G3 facsimile machine to the TEL
connector of the VoIP-TA unit via a telephone cord.
To make facsimile connections, the other end terminal equipment should
be compliant with the ITU-T T.38 standard.
Analogue PSTN
Connect an analogue PSTN line to the LINE port at the rear of the VoIP-TA
unit via a telephone cord.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
5
Personal computer (PC)
Connect a PC connector to the PC port at the back of the VoIP-TA unit
using an unshielded twisted pair (UTP) straight cable (categories 3 to 5).
If both a PC and LAN are to use 100BASE-TX communications, use
category 5 [max. 100m].
It is recommended that only one PC is connected to avoid voice deterioration.
Note
LAN
Connect the LAN connector to the LAN port at the back of the
VoIP-TA unit via a cross cable (UTP categories 3 to 5). If connecting to a
hub, use a straight cable.
If the LAN is connected by 100BASE-TX and the PC is connected by
100BASE-TX, or if the PC is not connected, use a category 5 cable
[max. 100 m].
CONSOLE (setting up the VoIP-TA with a PC)
Connect the PC for setup on the VoIP-TA by using the serial cable RS-
232C (9 pin – 9 pin straight) to the CONSOLE port.
FG (grounding)
After connecting the frame ground (FG) cable to the FG port at the back
of the VoIP-TA unit, connect the other end to a ground terminal in the
house or ground it separately.
Power source
Connect the supplied AC adapter to the DC IN 12V port at the back of the
VoIP-TA unit. Connect the attached AC adapter to a power outlet.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
6
Cautions
During installation
•
•
•
All cables used to connect the equipment must be accessories of the
equipment or suitable to fit the equipment.
Make sure the AC power plug is disconnected from the power outlet
when connecting the FG cable to the unit.
When an exchange machine, such as PBX or EKTS is connected to the
TEL port of VoIP-TA, the sound quality may deteriorate. Only one
exchange machine should therefore be relayed between the VoIP-TA unit
and telephones.
•
•
Interference noise may occur during telephone calls in areas that receive
strong radio waves, such as near a broadcasting station or CB radio
transmission. If calls are affected in this way, consult your network
manager, an authorized sales agent or service office.
Do not install the VoIP-TA unit near equipment that generates
magnetism or radio waves such as TV sets, radios, radio machines,
microwave ovens, or inverter-type fluorescent lamps, as this may cause
the unit to malfunction.
During use
•
Do not subject the unit to strong impact, such as dropping the unit.
•
Do not force cables to connect or disconnect as this may result in faults.
The connector and port should join with reasonable ease.
•
When cleaning the exterior of the VoIP-TA, turn it off and disconnect the
unit (by pulling the power plug, not the cord), wipe it with a water damp
cloth and wipe it dry with a soft dry cloth. Do not use volatile thinner,
alcohol or a silicon cleaner under any circumstances as it may result in
damage, discoloration or deformation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
7
III
Placing Calls
Via an IP network
Placing and receiving calls with the VoIP-TA unit are usually quite simple
and performed in the same way as conventional telephone networks. In
some cases however, the phone numbers to be used, may differ slightly
from the ones you used previously.
General operation
Outgoing calls
Use a telephone that generates a Dual Tone Multiple Frequency (DTMF)
signal. Pick up the handset and dial a remote party’s telephone number.
Incoming call response
An incoming tone will be emitted from the telephone.
Disconnection
A telephone call can be disconnected by hanging up the handset onto the
telephone receiver.
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
8
Services
Third party incoming call during another call
You can respond to a third party’s incoming call while you are on
another call.
•
A second party
telephone call.
•
If a third party calls, a
notification tone is sent
to your telephone.
•
You may speak to a
third party by hooking.
* The operation varies
depending on the data
settings. See Details of
Services p. 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
9
End-to-end service using DTMF signaling
DTMF signaling can be used via the IP network for answering machines,
etc. This service is unavailable when the facsimile transmission, via the
VoIP line, is set in the data setup. For details of the data setup, please
contact your network manager.
•
Making a telephone call
Call transfer during a telephone call
You can transfer a call during a telephone call. This service is unavailable
when the PSTN is set in the data settings. For details of the data setup,
please contact your network manager.
•
During a telephone call
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
10
•
•
•
Put the other party on
hold by hooking, and
dial a transfer
destination number.
You may then speak to
the party at the
transfer destination.
When you hang up the
handset again the call
will be automatically
transferred to the
destination.
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
11
Absent service
If the absent service is registered, an incoming call is transferred to a
registered destination. The transferred call will not be transferred any
further.
This service is inapplicable when a PSTN is set in the data setup. For
details of data setup, please contact your
network manager.
How to register the absent service
Pick up the handset, dial “***11” and the
“destination number to be transferred” and
hang up the handset. When the service is set,
the LINE-LED lamp will blink.
How to cancel the absent service
Pick up the handset, dial “***12,” and hang up
the handset. When the service is cancelled, the
LINE-LED lamp will go off.
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
12
Details of services
There are two ways to use the VoIP-TA unit; using both a PSTN line and
the IP network or using only the IP network. These services are
determined by the data setup.
Using both a PSTN line and the IP network
Line selection
The selection of a PSTN line or IP network is specified by the first digit of
the phone number set by the Maintenance Console Software. Please follow
the instructions provided by your network manager.
Third party incoming call during another call
For PSTN line receiving services using hookflash (hooking) from
regional telephone service company.
•
Response to incoming calls from a PSTN line during a telephone
call using the IP network.
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
13
•
Response to an incoming call from the IP network during a
telephone call using a PSTN line.
•
Incoming operation from the IP network during a telephone call
using the IP network.
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
14
For PSTN line not receiving services using hookflash (hooking).
•
Response to an incoming call from a PSTN line during a telephone
call using the IP network.
•
Response to an incoming call from the IP network during a
telephone call using a PSTN line.
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
15
•
Incoming operation from the IP network during a telephone call
using the IP network.
Using the IP network only
Incoming call during an existing telephone call.
Download from Www.Somanuals.com. All Manuals Search And Download.
Placing Calls
16
IV
Troubleshooting
If you encounter irregularities with the equipment, please check the
following list before making inquiries to authorized sales agents or
service offices.
Symptom
Items to check
Unit does not
operate.
• Is the power turned on? Check the POWER
lamp to see if it is lit.
• Is the power plug inserted into the port correctly?
• Is the AC power adapter connected to the
power outlet correctly?
The ALARM lamp
continues to blink.
The unit does not
operate.
• Is the LAN port link established?
No calls can be
made.
• Is the POWER lamp ON and the ALARM lamp
OFF?
• Is the unit properly connected to the
corresponding port?
• Is the LAN port link established? Check the LAN
lamp to see if it is lit.
• Is the dial signal of the telephone set correctly?
(TEL port: DTMF signal. Telephone lines vary
depending upon the contract with your regional
telephone company.)
No calls are
received.
• Is the POWER lamp ON and the ALARM lamp
OFF?
• Are all the connectors properly connected to the
correct ports?
• Is the LAN port link established? Check the LAN
lamp to see if it is lit.
• Is the ringer of the telephone in the ON position?
FAX communication • Is the POWER lamp ON and the ALARM lamp OFF?
is not available. • Is the facsimile mode a G3?
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
17
V
Specifications
Dimensions
Approx. 47 (W) x 185 (D) x 155 (H) [mm]
Approx. 0.42 [kg]
Weight
Power dissipation
Temperature range
9 [W] or less
0° C to 40° C
TEL port
Interface
Selection signal
Conventional analogue telephone line
DTMF signal
FAX transmission
speed
14,400 bps 12,000 bps 9,600 bps
7,200 bps 4,800 bps 2,400 bps
Number of
Only one
connectable ports
LAN port
PC port
Interface
10BASE-T/100BASE-TX
10BASE-T/100BASE-TX
Conventional analogue PSTN
DTMF signal
Interface
LINE port
Interface
Selection signal
CONSOLE port Interface
RS232C (19,200 bps)
TCP/IP
Call control
system
Protocol
Procedure
ITU-T recommended H.323 Version 2
UDP/IP
Voice real-time Protocol
transfer system
Real-time procedure RTP/RTCP
Voice control
FAX
Voice codec protocol G.711 (µ-law, A-law), G.729A and G.723.1
Protocol TCP/IP, UDP/IP
Real-time procedure T.38
Data setting
Interface
Max. 32
Local: RS232C Remote: LAN
Number of
Tel. No. digits
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
18
Important Equipment Information
The following information relates to the VoIP-TA compliance with radio
interference requirements of various countries in which this equipment
is sold.
EU Model
VoIP-TA conforms to the following directives:
•
•
•
Low Voltage Directive: 73/23/EEC
EMC Directive: 89/336/EEC
R&TTE Directive: 1999/5/EC (Annex II)
Compliance with these directives implies conformity to the following
European norms:
Safety: EN60950: 1992+A1+A2+A3+A4+A11
EMC:
EN55024: 1998
EN55022: 1998
EN 61000-3-2: 1995+A1+A2
EN 61000-3-3: 1995
R&TTE: TBR21: 1998
ETSI EG 201 121: v1.1.2
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Equipment Information
19
Warranty and Service
Our authorized sales agents or service office will respond to your
inquiries and services in a prompt and courteous manner.
Warranty period
In the event of a problem occurring during the warranty period, all
necessary repairs and replacements will be done free of charge except in
the following circumstances:
•
•
•
•
Failure or damage that occurred because the equipment was dropped
or handled roughly.
Failure or damage due to fire, earthquake, storm or flood, lightning or
other extraordinary natural event.
Damage due to moisture or salt intrusion, environmental pollution, or
the application of abnormal voltage.
Failure or damage due to improper operation of the equipment,
maintenance, repair, or modification by unauthorized service staff or
agents.
Following the warranty period
The cost of replacement parts will be charged after expiry of the
warranty period.
Please contact the authorized sales agents or service offices for inquiries
regarding service.
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty and Service
20
Oki Service Offices
Your Local Dealer
Oki Electric Industry Co., Ltd.
Head Office
10-3 Shibaura 4-chome,
Minato-ku, Tokyo 108-8551
JAPAN
Tel: +81-3-5445-6346/6353
Fax: +81-3-5445-6363/6364
London Office
Central House, Balfour Road
Hounslow, Middlesex TW3 1HY
U.K.
Tel: +44-208-219-2110
Fax: +44-208-219-2205
Sydney Office
63-85 Victoria Street
Alexandria, NSW 2015,
Australia
Tel: +61-2-9310-5711
Fax: +61-2-9310-4611
Oki Network Technologies
1101 Cadillac Court
Milpitas, CA 95035
U.S.A.
Tel: +1-408-935-3331
Fax: +1-408-935-3337
Download from Www.Somanuals.com. All Manuals Search And Download.
Oki Service Offices