METROLOGIC INSTRUMENTS, INC.
MS2x20 Stratos® Series
Configuration Addendum
Mettler Toledo Diva Scale
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
IMPORTANT NOTES - BEFORE YOU START ................................................................. 1
Scale Internal Beeper............................................................................. 9
Zero Cursor.......................................................................................... 10
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
MSS Global.......................................................................................... 27
Retailix / OPOS.................................................................................... 31
Prefix/Suffix.......................................................................................... 40
StratosSTATS...................................................................................... 50
Vertical Depth of Field.......................................................................... 59
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
EAS Timeout........................................................................................ 67
EAS Connection................................................................................... 72
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT NOTES - BEFORE YOU START
It is important to read carefully the notes marked with a
symbol on the pages
contained in this manual. Not all configuration codes are designed to be used for
both a single and dual cable scanner/scale system. Many of the configuration
bar codes require additional steps before the unit can be configured and placed
into service. Most of the bar codes in this addendum were designed to be used
with a Stratos model that includes a scale. The text marked with a
symbol will
provide important additional information about the restrictions and uses of the bar
codes shown.
All of the bar codes in this manual require:
•
•
The scanner/scale to have a firmware number of 15367 or higher
All configuration bar codes must be scanned with the vertical window
The Unit Configuration bar codes (located on pages 3 and 4 of this
addendum guide) require the scale security seal to be broken.
If the scale security seal is broken, it must be sealed and certified by local
Weights and Measures authorities after the scale calibration process has been
completed. The scanner/scale cannot be placed in service until it is sealed and
certified by the proper authorities.
For further details on calibration procedures for Weights and Measures
certification, refer to the Scale Operation: Calibration section of the Stratos
Installation and User’s Guide.
The certification of the weighing mechanism of the scale version of
this scanner is subject to federal, state and local Weights and
Measures statutes and regulations and can only be performed by
authorized government agencies and/or their duly registered
agents. Each time the scale or weighing mechanism is calibrated,
it should be properly sealed with a paper seal or a wire seal prior to
being placed into service in commerce.
It is the responsibility of the owner of the scale to confirm
compliance with the relevant Weights and Measures statutes and
regulations applicable in your area by checking with the appropriate
government agency before placing a newly calibrated unit into
service or removing any official seals.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT NOTES - BEFORE YOU START
Important Bar Codes
Scale Save Data Bar Code.
The Scale Save Data bar code must be scanned last to “save” the changes in the
scale’s memory. The scale will then reset and begin normal operation. This is
required only for scale configuration items – not for calibration.
Scale Save Data
³
9
9
6
0
4
5
Scale Type Bar Code.
The Stratos scanner should have been already programmed to recognize the
type K Diva scale. If, for any reason, the scanner’s non-volatile memory is lost,
the following bar code must be scanned to reprogram the scanner for the
type K Diva scale.
Type K Diva Scale
³
4
4
6
5
1
0
2
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE/LOAD CELL CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Unit Configuration (Pounds)
For Kilogram weight units see page 4.
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 must be in scale service mode to use these
bar codes.
Pounds Calibration
Set the scale measuring range from
0.00 to 30.00 pounds.
³
9
9
6
0
4
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE/LOAD CELL CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Unit Configuration (Kilograms)
For Pound weight units see page 3.
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 must be in scale service mode to use these
bar codes.
Kilograms Calibration
Set the scale measuring range from
0.000 to 15.000 kilograms.
³
9
9
6
0
4
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Pole Display Configuration
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale Display
Set the scale to use a single-line weight only
Single-Line Weight Only
display to show all scale activity.
The single-line display must be plugged into
the Scale to Display connector on the
MS2xx0 (see Figure 1).
³
9
9
6
0
0
3
Figure 1. Location of Scale to Display Connector
Scale Display
4-line Price Computing
Set the scale to use a 4-line price computing
display to show all scale activity.
The 4-line display must be plugged into the
Scale to Display connector on the MS2xx0
(see Figure 1).
³
9
9
6
0
0
9
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Pole Display Configuration
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale Has No Display
Set the scale to not require a remote
display. All weights are expected on a POS
terminal display.
A remote display can not be plugged into
the Scale to Display connector on the
MS2xx0 (see Figure 1).
³
9
9
6
0
0
4
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Scale Settling Filter Configuration
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
The scale’s filter setting allows the unit to withstand a certain amount of vibration
from the checkout counter. A stronger filter allows for more vibration to be
absorbed but the weight may take a little longer to settle. Scales are normally
shipped with a loose filter.
* Scale = Loose Filter
Loose filter setting for low vibration
environments.
* Factory Default Setting
³
9
9
6
0
0
5
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Scale Settling Filter Configuration
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = Medium Filter
Medium filter setting for moderate vibration
environments.
³
9
9
6
0
0
6
Scale = Strong Filter
Strong filter setting for high vibration
environments.
³
9
9
6
0
0
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Scale Internal Beeper
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale Beep On
Enable the internal scale beeper to beep
when remote display keys are depressed.
³
9
9
6
0
9
0
*Scale Beep Off
Turn off the internal beeper inside the scale.
This is the desired default as the scanner
beeper is the main tone generator.
* Factory Default Setting
³
9
9
6
0
9
1
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Zero Cursor
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Zero Cursor Off
Turn off the zero cursor that appears on the
display when the scale is in the zero weight
area.
³
9
9
6
0
9
2
*Zero Cursor On
Enable the zero cursor to appear on the
display when the weight is within the zero
weight area.
* Factory Default Setting
³
9
9
6
0
9
3
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single or Dual Cable Scale Configuration Bar Codes
Quantitative Separator
The following bar codes can be used to configure a Single or
Dual Cable MS2xx0.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Decimal Pt Separator
Use a decimal point to separate the units
from fraction values on the remote display.
³
9
9
6
0
9
4
Comma Separator
Use a comma to separate the units from
fraction values on the remote display.
³
9
9
6
0
9
5
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
Scale Protocols
The following bar codes will change scale parameters intended for a
Dual Cable environment. To place the scanner in Dual Cable mode,
please refer to page 24.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = EPOS Protocol
Set the scale RS232 protocol to
Serial EPOS.
Communication Port Settings:
•
•
•
•
2400 Baud
7 Data Bits
1 Stop Bit
³
9
9
6
0
1
3
Even Parity
Set the scale RS232 protocol to
Modified Serial EPOS.
This Protocol does not require the POS
terminal to send the weight back to the scale
for validation.
Scale = EPOS2 Protocol
Communication Port Settings:
•
•
•
•
2400 Baud
7 Data Bits
1 Stop Bit
Even Parity
³
9
9
6
0
1
4
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
Scale Protocols
The following bar codes will change scale parameters intended for a
Dual Cable environment. To place the scanner in Dual Cable mode,
please refer to page 24.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = 8217 Protocol
Set the scale RS232 protocol to 8217.
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
³
9
9
6
0
5
0
Even Parity
Scale = 8213 Protocol
Set the scale RS232 protocol to 8213.
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
³
9
9
6
0
5
1
Even Parity
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
Scale Protocols
The following bar codes will change scale parameters intended for a
Dual Cable environment. To place the scanner in Dual Cable mode,
please refer to page 24.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = ICL Protocol
Set the scale RS232 protocol to Serial ICL.
Communication Port Settings:
•
•
•
•
2400 Baud
7 Data Bits
1 Stop Bit
³
9
9
6
0
4
9
Even Parity
Scale = EMEA
Special Configuration
Set the scale to EPOS protocol, kilograms,
with a remote display, loose filter, no price
computing, and scroll weight.
Communication Port Settings:
•
•
•
•
2400 Baud
7 Data Bits
1 Stop Bit
³
9
9
6
0
4
1
Even Parity
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
Scale Protocols
The following bar codes will change scale parameters intended for a
Dual Cable environment. To place the scanner in Dual Cable mode,
please refer to page 24.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = NCI Protocol
Reserved for Future NCI Protocol Variation
³
9
9
6
0
1
6
Scale = NCI-ECR Protocol
Set the scale RS232 protocol to NCI-ECR.
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
6
0
1
5
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
Scale Protocols
The following bar codes will change scale parameters intended for a
Dual Cable environment. To place the scanner in Dual Cable mode,
please refer to page 24.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
*NCI = 4 Status Bytes
Set the number of status bytes reported by
the NCI scale protocol to 4 status bytes.
³
9
9
6
0
5
2
* Factory Default Setting
NCI = 2 Status Bytes
Set the number of status bytes reported by
the NCI scale protocol to 2 status bytes.
³
9
9
6
0
5
3
16
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
Scale Protocols
The following bar codes will change scale parameters intended for a
Dual Cable environment. To place the scanner in Dual Cable mode,
please refer to page 24.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = Price
Compute Setup
Set the scale for price computing setup.
•
•
•
•
•
Price computing display
Dialog 06 Protocol
9600 Baud
Odd Parity
7 Data Bits, 1 Stop Bit
³
9
9
6
0
4
7
17
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
COM Port Settings (Baud Rate)
The following bar codes will change scale parameters intended for a
Dual Cable environment.
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes
below must be scanned after the Scale Protocol bar code in order to be
effective.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = 2400 Baud Rate
Set the scale baud rate for dual cable
applications to 2400 baud.
³
9
9
6
0
1
7
Scale = 9600 Baud Rate
Set the scale baud rate for dual cable
applications to 9600 baud.
³
9
9
6
0
1
8
18
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
COM Port Settings (Baud Rate)
The following bar codes will change scale parameters intended for a
Dual Cable environment.
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes
below must be scanned after the Scale Protocol bar code in order to be
effective.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = 19200 Baud Rate
Set the scale baud rate for dual cable
applications to 19200 baud.
³
9
9
6
0
1
9
Scale = 38400 Baud Rate
Set the scale baud rate for dual cable
applications to 38400 baud.
³
9
9
6
0
2
0
19
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
COM Port Settings (Data Bits & Parity)
The following bar codes will change scale parameters intended for a
Dual Cable environment.
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes
below must be scanned after the Scale Protocol bar code in order to be
effective.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = 7 Data Bits,
Odd Parity
Set the scale communication parameters to
7 data bits, odd parity.
³
9
9
6
0
2
1
Scale = 7 Data Bits,
Even Parity
Set the scale communication parameters to
7 data bits, even parity.
³
9
9
6
0
2
2
20
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
COM Port Settings (Data Bits & Parity)
The following bar codes will change scale parameters intended for a
Dual Cable environment.
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes
below must be scanned after the Scale Protocol bar code in order to be
effective.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = 8 Data Bits, No Parity Set the scale communication parameters to
8 data bit, no parity.
³
9
9
6
0
2
3
Scale = Odd Parity
Set the scale communication to odd parity.
³
9
9
6
0
2
4
21
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Dual Cable Scale Configuration Bar Codes
COM Port Settings (Data Bits & Parity)
The following bar codes will change scale parameters intended for a
Dual Cable environment.
If a Scale Protocol bar code from page 12 to 17 is used, the bar codes
below must be scanned after the Scale Protocol bar code in order to be
effective.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily
disconnect the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
Scale = Even Parity
Set the scale communication to even parity.
³
9
9
6
0
2
5
Scale = No Parity
Set the scale communication to no parity.
³
9
9
6
0
2
6
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SCALE CONFIGURATION BAR CODES
Single Cable Scale Configuration Bar Codes
Set Scale for Single Cable Communication
If the MS2xx0 is currently in a Dual Cable configuration, disconnect
and remove the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).
If your application requires single cable communication, scan the following bar
code to set the scale configuration to the single cable defaults as required by the
scanner.
Scale = Single Cable Interface Set the scale to communicate via the
single-cable interface.
³
9
9
6
0
1
2
23
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Dual Cable Scanner Configuration Bar Codes
Dual Cable Scanner Mode
The following bar codes can be used to place, as well as configure, the
scanner in Dual Cable mode.
The MS2xx0 does not need to be in scale service mode to use the
following bar codes.
Scanner = Dual Cable Mode
Places the scanner in Dual Cable mode.
In a dual cable environment, the scanner
and scale work independently. In this mode
the host must have a dedicated RS232 port
to receive the scale data and the bar code
data is sent via its own cable to a separate
communication port.
³
9
9
9
9
5
3
Communication Port Settings:
9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity
•
There are two methods of configuring the scanner to a stand-alone protocol:
• Scan the Dual Cable Mode bar code on this page (if a scale is used)
or
• If no scale is required, scan one of the single cable protocols on
pages 27 - 36 and then scan the No Scale bar code on page 48.
Dual Cable Scanner OPOS Mode
Use this bar code when the scanner is to be
Scanner Only
Dual Cable OPOS Defaults
setup using the OPOS drivers in the dual
cable mode.
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
9
9
1
1
24
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Dual Cable Scanner Configuration Bar Codes
Various Dual Cable Scanner Mode
The following bar codes can be used to configure a Dual Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
program mode.
REWE
Dual Cable RS232 - REWE
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
2 Stop Bit
³
9
9
7
0
1
0
Space Parity
TESCO UK
Dual Cable RS232 – TESCO UK
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
Odd Parity
³
9
9
7
0
1
3
25
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Dual Cable Scanner Configuration Bar Codes
IBM 3rd Generation 46xx and IBM OEM Full Speed USB
The following bar codes can be used to configure a Dual Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
IBM 3rd Generation
Communication
When scanned the Stratos will operate
as a table top scanner only.
Terminal configuration, IBM 4690.OS
terminal device group configuration
screen select:
#1 scanner or
#3 scanner.
³
9
9
9
9
5
2
IBM OEM Full Speed USB
Communication Defaults
When scanned the Stratos will operate
as a table top scanner only.
³
9
9
9
9
7
0
26
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
MSS Global
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
MSS Global, English
Scanner/Scale, Single Cable RS232
MSS Global Retail, English Units
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
Odd Parity
³
9
9
9
9
5
1
MSS Global, Metric
Scanner/Scale, Single Cable RS232 MSS
Global Retail, Metric Units
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
Odd Parity
³
9
9
9
9
5
0
27
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
ISS45
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
ISS45, English
Scanner/Scale, Single Cable RS232
ISS45, English Units
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
³
9
9
9
9
4
9
Even Parity
ISS45, Metric
Scanner/Scale, Single Cable RS232
ISS45, Metric Units
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
³
9
9
9
9
4
8
Even Parity
28
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
OPOS
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
OPOS, English
Scanner/Scale Single Cable RS232 OPOS,
English Scale Defaults
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
9
9
5
8
OPOS, Metric
Scanner/Scale Single Cable RS232 OPOS,
Metric Scale Defaults
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
9
9
5
7
29
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
Retailix/NCR
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
Retailix/NCR English
Scanner/Scale Single Cable RS232
Retailix/NCR Communication, English
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
9
9
5
6
Retailix/NCR Metric
Scanner/Scale Single Cable RS232
Retailix/NCR Comm, Metric
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
9
9
5
5
30
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
Retailix/OPOS
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
Retailix / OPOS Metric
Scanner/Scale Single Cable RS232 Retailix
/ OPOS Communication, Metric
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
7
0
1
9
31
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
IT Retail
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
IT Retail, English
Scanner/Scale Single Cable RS232
IT Retail, English
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
Odd Parity
³
9
9
7
0
0
8
IT Retail, Metric
Scanner/Scale Single Cable RS232
IT Retail, Metric
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
Odd Parity
³
9
9
7
0
0
9
32
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
IBM Self Checkout System
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
program mode.
IBM Self Checkout System,
English
Scanner/Scale Single Cable RS232 -
IBM Self Checkout System, English
Communication Port Settings:
•
•
•
•
19200 Baud
7 Data Bits
1 Stop Bit
³
9
9
7
0
2
0
Odd Parity
Scanner/Scale Single Cable RS232 -
IBM Self Checkout System, Metric
IBM Self Checkout System,
Metric
Communication Port Settings:
•
•
•
•
19200 Baud
7 Data Bits
1 Stop Bit
³
9
9
7
0
2
1
Odd Parity
33
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
Various RS232 Single Cable Codes
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
program mode.
Morrison’s Tec Metric
Scanner/Scale Single Cable RS232 –
Morrison’s with Tec Display, Metric
Communication Port Settings:
•
•
•
•
9600 Baud
7 Data Bits
1 Stop Bit
Odd Parity
³
9
9
7
0
2
3
Reliance India Metric
Scanner/Scale Single Cable RS232 -
Reliance India, Metric
Communication Port Settings:
•
•
•
•
9600 Baud
8 Data Bits
1 Stop Bit
No Parity
³
9
9
7
0
1
9
34
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
IBM 3rd Generation 46xx
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
IBM 3rd Generation 46xx,
English†
Scanner/Scale Single Cable IBM 46xx†,
RS485, English (lbs.)
³
9
9
9
9
6
0
†
Terminal Configuration, IBM 4690.OS Terminal Device Group
Configuration screen select:
#2 Scanner with integrated scale
or
#4 4696 scanner/scale
IBM 3rd Generation 46xx,
Metric†
Scanner/Scale Single Cable IBM 46xx†,
RS485, Metric (kg)
³
9
9
9
9
5
9
35
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Single Cable Protocols for POS Compatibility
IBM OEM Full Speed USB
The following bar codes can be used to configure a Single Cable
MS2xx0.
The following codes do not require that the MS2xx0 to be in scale
service mode.
IBM OEM
Full Speed USB, English
Table Top Scanner/Scale Single Cable,
IBM OEM Full Speed USB, 4-Digit Weight
Mode, English (lbs.)
³
9
9
9
9
6
2
IBM OEM
Full Speed USB, Metric
Table Top Scanner/Scale Single Cable,
IBM OEM Full Speed USB, 5-Digit Weight
Mode, Metric (kg)
³
9
9
9
9
6
1
36
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Full Speed USB Table Top/Handheld
The following codes do not require that the MS2xx0 to be in scale
service mode.
Scanner 4B Handheld
Full Speed USB interface to 4B00h
handheld usage.
³
3
1
6
4
3
0
Scanner 4A Flatbed
Full Speed USB interface to 4A00h
table top usage.
³
3
1
6
4
1
0
37
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Full Speed USB Table Top/Handheld
The following codes do not require that the MS2xx0 to be in scale
service mode.
Scanner/Scale 4A/6E
Table Top
Full Speed USB interface to the
4A00h/6E00h table top scanner/scale
usage.
This option is only compatible with Stratos
models that have a scale.
³
3
1
6
4
4
0
38
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Special Function ACK
The following codes do not require that the MS2xx0 to be in scale
service mode.
Enable Special
Answer simple special functions with ACK.
Function ACK Answer
³
1
4
1
7
1
4
* Disable Special
Function ACK
³
1
4
1
7
0
4
* Factory Default Setting
39
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Prefix/Suffix
The following codes do not require that the MS2xx0 to be in scale
service mode.
Use Protocol Prefix/Suffix
Add protocol prefixes and suffixes to the
bar code.
³
1
4
1
7
1
5
* Program the
Prefix/Suffix Separate
³
1
4
1
7
0
5
* Factory Default Setting
40
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
3x-30 Acknowledge Responses
The following codes do not require that the MS2xx0 to be in scale
service mode.
No 3x-30 Answer
This bar code will inhibit all ‘simple
acknowledge’ (3x-30) answers to POS or
OPOS commands.
³
1
4
1
7
1
0
*3x-30 Answer
The scanner will answer all NCR and OPOS
commands that require a 3x-30
acknowledgement.
³
1
4
1
7
0
0
* Factory Default Setting
41
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Special Function Command Responses
The following codes do not require that the MS2xx0 to be in scale
service mode.
Spec Func Ans 3x30
Answer Special Function commands in the
3x-30 format as opposed to the Ack / Nak
which is the norm.
³
1
4
1
9
1
4
*Spec Func Ans Ack
Answer Special Function commands in the
Ack / Nak format.
³
1
4
1
9
0
4
* Factory Default Setting
42
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Special Function Command Responses
The following codes do not require that the MS2xx0 to be in scale
program mode.
Spec Func 30-30 Status
Returns Special Function commands in the
30-30 status as opposed to the 33-30 status.
Note: Requires ‘Spec Func Ans 3x-30’ on
page Error! Bookmark not defined. to be
set.
³
1
4
2
2
1
5
*No Spec Func 30-30 Status
Disables redirection of Special Function
3x-30 status to 30-30 status.
³
1
4
2
2
0
5
* Factory Default Setting
43
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Special Function Command Responses
The following codes do not require that the MS2xx0 to be in scale
program mode.
No Command Reject Answer
This bar code will ignore sending a
command reject answer to the POS mode.
³
1
4
2
1
1
7
*Send Command Reject
This bar code will send command reject
answer to the POS if the command is
rejected by the scanner.
Answer
³
1
4
2
1
0
7
* Factory Default Setting
44
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Special Function Command Responses
The following codes do not require that the MS2xx0 to be in scale
program mode.
No Spec Func Answer
This bar code will ignore sending a special
function response answer in POS mode.
³
1
4
2
1
1
6
*Spec Func Answer
This bar code will send a special function
response answer to the POS.
³
1
4
2
1
0
6
* Factory Default Setting
45
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
BCC in POS communications
The following codes do not require that the MS2xx0 to be in scale
service mode.
Skip BCC in messages
This bar code will tell the scanner to NOT
expect or transmit the Block Check
Character in all message transmissions..
³
1
4
1
4
1
0
*Add BCC in messages
The scanner will expect and answer all
messages with the Block Check Character
included.
³
1
4
1
4
0
0
* Factory Default Setting
46
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
3 Scale Status Bytes
The following codes do not require that the MS2xx0 to be in scale
service mode.
Enable
3 Scale Status Bytes
Required for applications where the host
system display is the primary scale display
and there is no remote pole display
connected directly to the scanner/scale unit.
³
1
2
4
8
1
3
Disable
3 Scale Status Bytes
³
1
2
4
8
0
3
47
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Scale Options
The following codes do not require that the MS2xx0 to be in scale
service mode.
5-Digit Weight
Sets the English Mode weight to 5-digits, as
in xx.yyy pounds.
In order to work properly, this bar code must
be scanned AFTER scanning one of the
English configuration bar codes found on
pages 27 - 36.
³
1
4
1
0
1
0
Scan the No Scale bar code:
1. If no scale is installed and one of the
single cable protocol bar codes found
on pages 27 - 36 has already been
scanned.
No Scale
2. If the scale is in a dual cable
environment and one of the single cable
protocol bar codes found on
pages 27 - 36 has already been
scanned.
³
1
4
1
4
0
7
48
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
Remote Display
The following codes do not require that the MS2xx0 to be in scale
service mode.
No Remote Display
When no remote display is installed, scan
the No Remote Display bar code AFTER
scanning one of the configuration bar codes
found on pages 27 - 36 to remove the
scale’s display from the scanner memory.
³
1
4
0
9
0
2
Remote Display
Add remote display to the scanner’s
memory.
³
1
4
0
9
1
2
49
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
StratosSTATS
The following codes do not require that the MS2xx0 to be in scale
service mode.
Activate StratosSTATS
This bar code sets:
a. StratosSTATS bar code data
formatting active.
b. Bar code Attempt Interval to
0.5 seconds.
c. Time to find supplements (code 128)
to 0.3 seconds.
³
9
9
7
0
1
7
Use StratosSTATS monitor to test this
output format. When used with a POS, it
must have the capability to parse and
recognize the additional data.
*StratosSTATS Off
Remove StratosSTATS data formatting from
the bar code output transmission.
³
9
9
7
0
1
8
* Factory Default Setting
50
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
StratosSTATS
The following codes do not require that the MS2xx0 to be in scale
program mode.
Do not scan these bar codes unless instructed by a Metrologic
Representative.
Dual Stats Xmit
Allows non-RS232 interfaces transmit
normally without StratosSTATS and
concurrently RS232 interfaces transmit with
StratosSTATS.
Recommended RS232 Settings:
³
1
3
8
5
1
1
•
•
•
•
•
38400 Baud
8 Data Bits
1 Stop Bit
No Parity
No Inter-character Delay
*No Dual Stats Xmit
³
1
3
8
5
0
1
* Factory Default Setting
51
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Data Formatting
StratosSTATS
The following codes do not require that the MS2xx0 to be in scale
program mode.
Do not scan these bar codes unless instructed by a Metrologic
Representative.
Dual Xmit Carriage Return
This bar code enables a secondary carriage
return suffix to be used only for the dual
StratosSTATS RS232 transmission.
³
1
3
8
5
1
2
*No Dual Xmit Carriage Return Resets StratsSTATS RS232 dual
transmission suffix.
³
1
3
8
5
0
2
* Factory Default Setting
52
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Related Functions
Scanner Beep on Weight Sent
The following codes do not require that the MS2xx0 to be in scale
service mode.
Beep on Weight
Request scanner beep when a successful
weight is sent. This code should only be
used for ‘weight on demand’ applications. If
used with periodic weight request
applications, the beeper will be continuously
active (ON).
³
1
4
1
9
1
7
*Disable
Beep on Weight
When no beep on weight is desired.
³
1
4
1
9
0
7
* Factory Default Setting
53
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Related Functions
Restrict In-Store Codes
The following codes do not require that the MS2xx0 to be in scale
program mode.
Restrict In-Store Codes
This bar code places tighter restrictions on
in-store codes. These codes are:
EAN13 Sys2
UPCA Sys2 and Sys4
³
1
2
5
8
1
0
*No Restrict In-Store Codes
Disable restrictions on in-store codes.
³
1
2
5
8
0
0
* Factory Default Setting
54
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Related Functions
Scale Shadow Mode
The following codes do not require that the MS2xx0 to be in scale
program mode.
Scale Shadow Mode
This bar code sets the scale to the highest
priority to allow for frequent scale - POS
commands.
This bar code is only to be used in single
cable scale mode.
³
1
4
2
2
1
7
*No Scale Shadow Mode
Disables the Scale Shadow Mode.
³
1
4
2
2
0
7
* Factory Default Setting
55
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional POS Related Functions
Scanner Razz on Not-On-File
The following codes do not require that the MS2xx0 to be in scale
program mode.
Razz on Not-On-File
This bar code changes the audible to a razz
signal when a Not-On-File command is
received.
³
1
4
2
1
1
5
*Beep on Not-On-File
This bar code restores the beep as the Not-
On-File audible.
³
1
4
2
1
0
5
* Factory Default Setting
56
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional Scanner Configuration Bar Codes
Horizontal Depth of Field
The following codes do not require that the MS2xx0 to be in scale
program mode.
Do not scan these bar codes unless instructed by a Metrologic
Representative.
*Horizontal High DOF
This bar code sets the DOF for all horizontal
laser channels to High DOF, which allows
the farthest scanning.
³
2
1
8
7
0
2
* Factory Default Setting
Horizontal Medium DOF
This bar code sets the DOF for all horizontal
laser channels to Medium DOF.
³
2
1
8
7
1
2
57
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional Scanner Configuration Bar Codes
Horizontal Depth of Field
The following codes do not require that the MS2xx0 to be in scale
program mode.
Do not scan these bar codes unless instructed by a Metrologic
Representative.
Horizontal Close DOF
This bar code sets the DOF for all horizontal
laser channels to Close DOF.
³
2
1
8
7
2
2
Horizontal Ultra Close DOF
This bar code sets the DOF for all horizontal
laser channels to Ultra Close DOF.
³
2
1
8
7
3
2
58
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional Scanner Configuration Bar Codes
Vertical Depth of Field
The following codes do not require that the MS2xx0 to be in scale
program mode.
Do not scan these bar codes unless instructed by a Metrologic
Representative.
*Vertical High DOF
This bar code sets the DOF for the vertical
laser channels to High DOF, which allows
the farthest scanning.
³
2
1
8
7
0
0
* Factory Default Setting
Vertical Medium DOF
This bar code sets the DOF for vertical laser
channels to Medium DOF.
³
2
1
8
7
1
0
59
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Additional Scanner Configuration Bar Codes
Vertical Depth of Field
The following codes do not require that the MS2xx0 to be in scale
program mode.
Do not scan these bar codes unless instructed by a Metrologic
Representative.
Vertical Close DOF
This bar code sets the DOF for the vertical
laser channels to Close DOF.
³
2
1
8
7
2
0
Vertical Ultra Close DOF
This bar code sets the DOF for vertical laser
channels to Ultra Close DOF.
³
2
1
8
7
3
0
60
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Auxiliary Port
StratosSCHOOL™
The following codes do not require that the MS2xx0 to be in scale
service mode.
Auxiliary History Report
The Auxiliary port may be used to download
or clear data to StratosSCHOOL™.
The two commands that can be used are
Upload Scanner Data and Clear Scanner
Data within the Serial Program Interface box
on the StratosSCHOOL™ screen.
³
9
9
7
0
1
1
Auxiliary Program Cable
(MLPN 57-57008x-N-3) is required
for this feature.
61
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Auxiliary Port
Quick Start for a Secondary Metrologic Scanner
The following codes do not require that the MS2xx0 to be in scale
service mode.
STEP 1
Use the Stratos to scan the following bar code. This bar code will configure
the Stratos’ auxiliary port to accept a Metrologic scanner as the secondary
scanner.
Enable Stratos Auxiliary Port
³
4
3
7
3
2
0
The auxiliary input port’s data format must match the main output format
of the secondary scanner
STEP 2
Configure the secondary scanner to match the auxiliary port’s data format.
Use the Secondary Scanner to scan the following bar codes in the order
shown.
Enter Configuration Mode
³
9
9
9
9
9
9
Enable Auxiliary Output
³
1
2
4
8
1
7
62
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
Auxiliary Port
Quick Start for a Secondary Metrologic Scanner
Configuration sequence continued from previous page.
Set Stratos Format
³
4
3
7
5
2
0
Disable Secondary
Scanner Beeper
³
3
1
8
5
0
5
Enable Communication
Time Out
³
1
1
8
4
1
2
Disable CR Suffix
³
1
1
6
6
0
3
Disable LF Suffix
³
1
1
6
6
0
2
Exit Configuration Mode
³
9
9
9
9
9
9
63
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Device Types
The following codes do not require that the MS2xx0 to be in scale
program mode.
*No EAS Device
No EAS device is connected.
³
3
3
7
2
0
0
* Factory Default Setting
EAS Device Type 1
³
3
3
7
2
1
0
64
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Device Types
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS Device Type 2
³
3
3
7
2
2
0
EAS Device Type 3
³
3
3
7
2
3
0
65
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Device Types
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS Device Type 4
³
3
3
7
2
4
0
66
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Timeout
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS = 2 seconds
³
8
4
6
0
0
2
0
0
EAS = 3 seconds
³
8
4
6
0
0
3
0
0
68
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Timeout
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS = 4 seconds
³
8
4
6
0
0
4
0
0
EAS = 5 seconds
³
8
4
6
0
0
5
0
0
69
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Timeout
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS = 7 seconds
³
8
4
6
0
0
7
0
0
EAS = 10 seconds
³
8
4
6
0
1
0
0
0
70
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Timeout
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS = 15 seconds
³
8
4
6
0
1
5
0
0
EAS = 20 seconds
³
8
4
6
0
2
0
0
0
71
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Connection
The following codes do not require that the MS2xx0 to be in scale
program mode.
*EAS Digital Aux Port
The EAS signals use the RTS and CTS line
of the Auxiliary RS232 In connector.
³
1
4
6
1
0
0
* Factory Default Setting
EAS Digital Host Port
The EAS signals use the RTS and CTS lines
of the scanner RS232 to Host connector.
³
1
4
6
1
1
0
72
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Connection
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS RS232 on Aux Port
This bar code allows the EAS RS232 signal
to use the Tx Out and Rx In lines of the
scanner to Aux RS232 In connector.
³
1
4
6
1
1
1
*No EAS RS232 on Aux Port
There is no EAS RS232 signal (Tx Out and
Rx In) used on the scanner Aux RS232 In
connector.
³
1
4
6
1
0
1
* Factory Default Setting
73
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Connection
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS RS232 on Host Port
This bar code allows the EAS RS232 signal
to use the Tx Out and Rx In lines of the
scanner to Host RS232 In connector.
³
1
4
6
1
1
2
*No EAS RS232 on Host Port
There is no EAS RS232 signal (Tx Out and
Rx In) used on the scanner to Host RS232
In connector.
³
1
4
6
1
0
2
* Factory Default Setting
74
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
Continuous Mode
The following codes do not require that the MS2xx0 to be in scale
program mode.
EAS Continuous Mode
When in continuous mode and the scanner
is enabled, the EAS will always be online to
deactivate an EAS tag.
³
1
4
6
1
1
5
*EAS Interlock Mode
This bar code establishes EAS is used in the
Interlocked mode.
³
1
4
6
1
0
5
* Factory Default Setting
75
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Deactivation
The following codes do not require that the MS2xx0 to be in scale
program mode.
Blink Scan LED on
Deactivation
The scanner will blink the scan LED upon
receipt of an EAS deactivate acknowledge
signal.
³
1
4
6
1
1
3
*No Blink LED on Deactivation Do not blink the scan LED upon receipt of
an EAS deactivate acknowledge signal.
³
1
4
6
1
0
3
* Factory Default Setting
76
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Deactivation
The following codes do not require that the MS2xx0 to be in scale
program mode.
Fast Beep on Deactivation
Fast beep the scanner’s beeper receipt of
an EAS deactivate acknowledge signal.
³
1
4
6
1
1
4
*No Beep on Deactivation
Do not fast beep the scanner’s beeper
receipt of an EAS deactivate acknowledge
signal.
³
1
4
6
1
0
4
* Factory Default Setting
77
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
EAS Deactivation
The following codes do not require that the MS2xx0 to be in scale
program mode.
Volume Switch = Manual
The volume switch is used for manual EAS
deactivation switch.
³
1
4
6
1
1
6
*Volume Switch = Normal
Volume switch is used for normal volume
function.
³
1
4
6
1
0
6
* Factory Default Setting
78
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
Sensormatic ScanMax Pro
The following codes do not require that the MS2xx0 to be in scale
program mode.
The RS232 EAS cable must be connected to one of the RS232 scanner
ports.
EAS Function #1
For Sensormatic ScanMax Pro, get EAS’s
deactivation count and transmit the
information over the current scanner
interface.
³
9
9
8
0
6
5
EAS Function #2
For Sensormatic ScanMax Pro, get EAS’s
device type and transmits the information
over the current scanner interface.
³
9
9
8
0
6
6
79
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER CONFIGURATION BAR CODES
EAS Bar Codes
Sensormatic ScanMax Pro
The following codes do not require that the MS2xx0 to be in scale
program mode.
The RS232 EAS cable must be connected to one of the RS232 scanner
ports.
EAS Function #3
For Sensormatic ScanMax Pro, get EAS’s
hardware version, software version, and
serial number and transmit the information
over the current scanner interface.
³
9
9
8
0
6
7
ScanMax RS232 Defaults
For Sensormatic ScanMax Pro, RS232
default setup.
•
•
•
AUX port connect
5 second timeout
blink LED on deactivate
³
9
9
9
9
0
9
80
Download from Www.Somanuals.com. All Manuals Search And Download.
SCANNER TEST BAR CODES
Supplemental Tests
Display Software Numbers
The following codes do not require that the MS2xx0 to be in scale
service mode.
These codes are for test purposes only.
The following code will display software #’s on the 2-digit diagnostic display.
The lasers will be turned off while the numbers are being displayed. The first
number is the main decode processor software number. The second number is
the I/O processor’s software number. Since only 2 digits can be displayed at a
time, the following sequence is used as an example of what may be observed:
2-Digit
Display
Description of each sequentially displayed sets of digits.
(Example shown will represent: ‘ 15269’ ‘ 15138’)
The first digit of the five main decode processor software number
appears right justified.
x 1
5 2
6 9
x x
The second and third digits.
The forth and fifth digits.
Pause before next set of numbers.
The first digit of the five digit I/O processor software number
appears right justified.
x 1
5 1
3 8
The second and third digits.
The forth and fifth digits.
x = Blank / No Digit Displayed
After the last sets of digits are displayed, the scanner resumes scanning
operation. If the current interface does not use an I/O processor, the software
number may appear ‘ 0 00 00’. This capability exists in software 15269 and
later.
Display Software Number
³
9
9
8
0
6
2
81
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
May 2008
Printed in the USA
0 0 - 0 2 2 7 2 C
Download from Www.Somanuals.com. All Manuals Search And Download.
|