eDART™ System User Guide
Lynx™ Mold-Closed Limit Switch
L-LS
The Lynx™ L-LS Mold-Closed Limit Switch is a tie-bar or
machine mountable machine cycle input module designed to be
used with the eDART System™.
ꢀ
U
The L-LS switch can be used to easily get a machine trigger off of
most injection molding machines by following the installation steps
below.
Always power down before working on
any equipment.
Figure 25: Lynx™ Mold-Closed Limit Switch side view
L-LS Installation
Step 1.
Switch the molding machine to Manual mode and close
the mold.
!
U
Be careful to note the position of the
ejector plate, the mold, the limit switch
and its cable, so the limit switch and/or
its cable does not get caught as the
mold opens and closes.
Step 2.
Set the limit switch on the tie-bar as shown in figures 26
and 27.
Appendix
32
Download from Www.Somanuals.com. All Manuals Search And Download.
eDART™ System User Guide
Step 4.
Hold the limit switch in place and use a ty-wrap to tighten
it down to the tie-bar. See figure 29.
More than one ty-wrap can be tied together if the tie-bar is
large.
ꢀ
U
B
Always power down before working on
any equipment.
L-LS
A
C
D
Figure 29: Lynx™ Mold-Closed Limit Switch L-LS side view
A
B
C
D
Moving Half
Ejector Plate
Tie Bar
Tighten Ty-Wrap
Table 26: Figure Labels
Step 5.
Plug a Lynx™ cable between the limit switch and the
eDART System™.
Step 6.
Run the machine to ensure proper use, while monitoring
the eDART™ software.