TX500b SERIES
®
SMART TEMP ELECTRONIC THERMOSTAT
MO
UP
MO
UP
M
ORN
DA
V
GHT
H
E
A
T
M
ORN
DA
EV
NIGHT
H
E
A
T
Y
Y
E
E
PM
PM
DOWN
DOWN
T
EEKDA
PROGRAM
T
NDA
OGRAM
SET
WEEKDA
PROGRAM
SET
SUNDAY
PROGRAM
Y
Y
Y
RESET
RESET
FAN
FAN
HEAT
HEAT
AUTO
ON
AUTO
ON
OFF
OFF
HOLD
HOLD
COOL
COOL
/
RUN
SET
DAY/TIME
RUN
NEXT
NEXT
500
500
n
P
a
t
e
n
t
s
P
e
n
d
i
n
g
P
a
t
e
n
t
s
P
e
d
i
n
g
SIMPLIFIED INSTRUCTIONS
TO SET PROGRAMS
Rotate Dial to SET
SIMPLIFIED INSTRUCTIONS
TO SET TIME
&
DA
Y
TEMPORARY TEMPERATURE
OVERRIDE
TO SET TIME
&
DAY
TO SET PROGRAMS
• Rotate Dial to SET
TEMPORARY TEMPERATURE
•
Rotate Dial to set DAY/TIME.
•
•
Rotate Dial to set DAY/TIME.
OVERRIDE
Complete, Easy To Read Programming And Installation Instructions
I M P O R T A N T !
Thank you for your confidence in our product. To obtain the best
results from your investment, please read this manual and acquaint
yourself with your purchase before installing your new thermostat.
READ THE
TION
ALLA
INST
Then follow the installation procedures, one step at a time. This
will save you time and minimize the chance of damaging the
thermostat and the systems it controls. These instructions may
contain information beyond that required for your particular instal-
lation. Please save for future reference.
INSTRUCTIONS
.
FIRST
The Set Temperature
LUX
Speed Dial®
Fan Switch
Liquid
Crystal
Display
FEATURES
The Active
Program Period
•
The TX500 can be used with most 24
volt gas, oil or electric heating and air
conditioning systems or gas millivolt
heating systems. It cannot be used
with 120 volt heating systems or heat
pumps. Ask your dealer for other LUX
thermostats to control those systems.
System Switch
MO
UP
MORN
H
E
A
T
DAY
EVE
NIGHT
PM
DOWN
SET
SET
WEEKDAY
PROGRAM
SUNDAY
PROGRAM
RESET
HOLD
FAN
HEAT
•
•
The TX500 is programmable. There
are four programming periods per day.
Each period can be programmed
separately.
AUTO
OFF
ON
COOL
SET
DAY/TIME
RUN
NEXT
500
P a t e n t s P e n d i n g
You can use the built-in time/
temperature programs, or alter
them to suit your schedule. The
SIMPLIFIED INSTRUCTIONS
TEMPORARY TEMPERATURE
OVERRIDE
•Press UP/DOWN to
TO SET TIME
&
DAY
TO SET PROGRAMS
• Rotate Dial to SET
WEEKDAY,
• Rotate Dial to set DAY/TIME.
• Press UP to change
current day.
• Press NEXT.
• Press UP/DOWN to set time.
adjust set temperature.
•To clear OVERRIDE press
UP/DOWN until original set
temperature appears or wait
for the start tf the next period.
SATURDAY or
SUNDAY PROGRAM.
• Press UP/DOWN to
adjust start time.
TX500 provides separate programming
for weekdays and weekends — for both
heating and cooling. You can override the
programmed temperatures for as little as one
programming period or for an entire vacation.
• Press NEXT.
Rotate the
dial to
the RUN
position
to close
the door.
• Press UP/DOWN to
adjust temperature.
• Press NEXT.
• Repeat as needed or
rotate dial to RUN to
stop Programming.
TEMPERATURE HOLD
• Press HOLD. Adjust temperature
as desired with UP/DOWN.
•To clear, press HOLD again.
Thermostat
Body/Sub-base
Thermostat Cover
•
•
In cool weather, when the system switch is set to HEAT, the TX500 will maintain cooler “set back”
room temperatures to save energy. It will then change to warmer “comfort” settings - all automatically, at
specified times during the day.
In warm weather, when the system switch is set to COOL, the TX500 will maintain warmer “set back” room
temperatures to save energy. It will then change to cooler “comfort” settings - all automatically, at specified
times during the day.
•
•
•
A large liquid crystal display shows time, day of the week, and room and set temperatures.
5/2 Minute Selectable Minimum Run/Off Time for Short Cycle/Compressor Protection
Two Energizer® or DURACELL® “AA” alkaline batteries (not included) are used to retain your time and
.
temperature programs.
C
A
U
T
I
O
N
• Your thermostat is a precision instrument. Please handle it with care.
• Turn off electricity to the appliance before installing or servicing thermostat or any part of the system.
Do not turn electricity back on until work is completed.
• Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the
system. This will damage the thermostat and void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt and millivolt systems. The thermostat should be
limited to a maximum of 1.0 amps; higher amperage may cause damage to the thermostat. If you are
in doubt, call your utility company.
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
TEMPERATURE OVERRIDE AND TEMPERATURE HOLD
OPERATION
These features let you change the current Set Temperature without changing the programs
stored in your thermostat’s memory.
This thermostat is “armchair programmable.” You can make any program or
setting changes with the thermostat body off or on the wall thermostat base.
TEMPORARY TEMPERATURE OVERRIDE
The TX500 alternately displays the current time and the room temperature. It also displays
the day of the week and the currently active control program that is controlling the temperature:
MORN, DAY, EVE, or NIGHT.
The set point temperature will appear in the right side of the display. In the winter, set the
system switch to HEAT to control your heating system. In the summer, set the switch to COOL
to control your air conditioner. In spring and fall or when windows are open, you can set the
system switch OFF.
Setting the FAN switch to AUTO automatically runs your system’s fan during heating and
cooling. Setting the FAN switch to ON runs your system’s fan continuously even without
heating or cooling.
•
•
•
Press UP/DOWN to change the current temperature
setting. The OVERRIDE indicator appears on display.
The Override feature will be automatically canceled
at the start of the next program period.
To cancel OVERRIDE prior to next program
period press UP/DOWN until original set temperature
appears. OVERRIDE indicator will disappear
from display.
M
O
MORN
DAY
H
E
A
T
EVE
PM
NIGHT
E
OVERRID
VACATION TEMPERATURE HOLD
N
O
T
E
The FAN switch works only if your system provides a wire for the TX500’s “G” terminal.
•
•
•
Press HOLD. Adjust temperature as
desired with UP/DOWN.
Temperature setting will not change even
after next program period begins.
M
O
MORN
DAY
H
E
A
T
THE BUILT-IN ENERGY STAR® PROGRAMS
EVE
PM
NIGHT
HOLD
To clear, press HOLD again.
PERIOD
HEAT
COOL
Push in the RESET key. This
sets the built-in heating and cooling
programs. To review the built-in
programs, rotate the dial to SET
WEEKDAY PROGRAM or SET
WEEKEND PROGRAM.
WEEKDAYS
preprograms
MORN
DAY
EVE
6:00 AM 70° 6:00 AM 78°
8:00 AM 62° 8:00 AM 85°
6:00 PM 70° 6:00 PM 78°
ADVANCED FEATURES
NIGHT 10:00 PM 62° 10:00 PM 82°
You can use the built-in programs
as shown, or change them as you
wish. Each day is divided into four
periods. Each period has its own
starting time
TEMPERATURE SWING
MORN
DAY
EVE
6:00 AM 70° 6:00 AM 78°
8:00 AM 62° 8:00 AM 85°
6:00 PM 70° 6:00 PM 78°
A thermostat works by turning your heating or cooling system on and off whenever the room
temperature varies a certain number of degrees from the set-point temperature. This variation is the
“swing.”
SAT & SUN
preprograms
NIGHT 10:00 PM 62° 10:00 PM 82°
Your system should cycle on about 3 to 6 times per hour. A smaller swing number increases the
number of cycles, so room temperature is more constant. A larger swing number decreases the
number of cycles, to save energy in most cases.
and temperature.
The dial must be in the RUN position to close the door.
Press together
SWING SETTINGS
PROGRAMMING THE TX500
To change
swing
Dial must be in
the run position
You can change any of the preset times and/or temperatures to suit your schedules for the
weekday and weekend programs. Each day is divided into four periods: Morning, Day,
Evening, and Night. Each period is programmed for HEAT and for COOL.
A blank programming chart is provided below for you to record your temperature settings in
that chart.
MORN
DAY
EVE
NIGHT
Press to set.
M
O
T
U
W
E
T
H
FR
Select HEAT to program the TX500 for
controlling your heater.
MORN
DAY
H
E
A
T
5 MIN/ 2 MIN MINIMUM ON/OFF TIME
HEAT
OFF
EVE
Your thermostat has an internal timer built in to protect your compressor. The timer forces a minimum on/off
time of 5 minutes. You may change this minimum on/off time to 2 minutes. To accomplish this, place the
jumper labeled JP3 over both pins. You must press the small reset button on the face of the thermostat for
the changes to take effect.
NIGHT
AM
OR Select COOL to program the TX500 for
controlling your air conditioner.
COOL
Rotate dial to SET WEEKDAY PROGRAM. To program the WEEKEND, rotate the dial to SET
WEEKEND PROGRAM. With dial on SET WEEKDAY PROGRAM, you will see this display.
CHANGING FROM °F TO °C AND A 12HR CLOCK TO A 24HR CLOCK
•
WARNING: Making these changes will require you to
reset
the thermostat. Copy any of your customized
programs onto the chart below. This will be your
reference to reenter the programs afterwards.
Located at the top center of the thermostat are
two jumpers - C/F and 12/24.
To change to Celsius - remove jumper - C/F.
To change to a 24HR clock - remove jumper- 24/12H.
Press the reset key on the front of the thermostat for
changes to take effect.
RC RH
W
Y
G
CLOSE OPEN
JP3 5MIN 2MIN
To change the start time
for MORN.
To change the start time
for EVE.
JP2
F
C
ELEC
GAS
JP1 12HR 24HR
To program temperature.
To program temperature.
JP3
JP2
JP1
To change the temp.
setting for MORN.
To change the temp.
setting for EVE.
•
To move to DAY.
To move to NIGHT.
•
•
•
To change the start time
for NIGHT.
To change start time
for DAY.
To program temperature.
To program temperature.
•
Reprogram as necessary.
To change the temp.
setting for NIGHT.
To change the temp.
setting for DAY.
Rotate dial to RUN position to
start the programs.
To move to EVE.
P R O G R A M M I N G
C H A R T
SETTING THE TIME AND DAY
DAY
PERIOD
HEAT
COOL
TIME
TEMP.
TIME
TEMP.
SU
DAY
C
A
U
T
I
O
N
MON.
THRU
FRI.
MORN
DAY
TEMP
The TX500 is protected against normal static electric discharges.
However, in extremely dry weather you should touch another metal
object before the TX500 to avoid potential loss of programs.
PM
EVE
NIGHT
MORN
DAY
Open the drop down door on the front of the thermostat. Rotate the dial to the SET
DAY/TIME position. You should see the display pictured above with a flag pointing to a day of
the week flashing. When you are finished setting the day and time, rotate the dial to RUN to
return to normal operation or to another position to continue programming.
SAT.
and
EVE
SUN.
NIGHT
To change
current day.
To set current time. The
time (e.g."12:00 AM")
will be flashing.
To change the
current time.
Download from Www.Somanuals.com. All Manuals Search And Download.
|