Lytecaster Recessed Downlighting 1104F13ESR
®
Page 1 of 1 6 3/4" Aperture 0 1 Lt 13W Quad / Triple Tube Compact Fluorescent IC Remodeler
4
3
6 5/8"
2 1/4"
3 5/16"
4 1/16"
2
5
1
7 1/8"
13 3/8"
Ceiling Opening 7" diameter
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Voltage Lamp
Enclosed
Wall
Cross Blades
Diffusers
Washer
AnodizedReflector AnodizedCone
Satin Cone
Baffles
Basic White
1104F13ESR
120V
13W
1143
1112
1108
1105
1170M1
1121
1185
1132**
Quad 1144
1112NM
1113
1108NM
1110
1110NM
1105BNM 1171
1105NM
1105WH
1176
1176WH
1179M1
1124
1126
1128**
1134
1177SH
1177LX**
1178SH
1178LX**
1190
1186
1186WH
1135
or
1144CD
Triple
Tube
1113BK
1113BKNM
1113CD
1113CDNM
1113NM
1113WH
1135WH
1179WH
Features
Labels
1. Housing: .032” (#20 ga.) UL listed for direct contact with thermal insulation.
Allows installation in ceilings up to 2" thick. Can be removed for access
to junction box, ballast and ceiling plenum. AirSeal® housing minimizes
air leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with
Model Energy Code (Section 602.3.3) and Washington State Energy Code
(Section 502.4) and reduces heat loss and condensation in ceiling.
2. Junction Box: 2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel.
UL listed for branch circuit wiring supplying connected luminaires. Integral
cable clamps permit attachment of non-metallic (#12 or #14 ga.) Romex®
cable without tools or additional connectors.
UL (Type IC Suitable for Damp Locations)
Complies with Air Leakage Requirements stated in the Model Energy Code,
California Title 24 and the Washington State Energy Code.
Romex® is a registered trademark of General Cable Industries Inc.
US and Foreign Patents Pending.
3. Socket Housing: Trim retaining spring secures trim to any height on
housing wall.
4. Socket: (4 Pin,GX24q-1) base, molded thermo-plastic. Pre-wired with #18
AWG leads to junction box.
5. Ballast: Electronic 120V, end of life protected, FCC class “B” consumer
limits, class “A” sound rating. Energy Star® qualified.
Job Information
Type:
Job Name:
Cat. No.:
Electrical
Input Watts: 16
Amps: .13
Ballast Factor: 1.0
Power Factor: .96
Max THD %: 10
Lamp(s):
Notes:
**Use Triple Tube Lamp Only
Min Start Temp: 0˚F/ -18˚C
Options & Accessories
AirSeal® Kit: LAS56R (optional)
(required for AirSeal Installation)
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • B0906