INSTRUCTION SHEET NO.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
IS:1104ICN
C1204
Page 1 of 2
INSTALLATION PROCEDURE FOR CONVERTIBLE IC/NON IC
FRAME-IN-KITS 1004ICN, 1004SICN, 1104ICN, 1104SICN
NEW CONSTRUCTION
Fig. B
Fig. C
Fig. D
Fig. E
Fig. F
Fig. A
Wire-In
Swing-Up
Close-In
Snap-On
Push-Up
Frame-In
SOCKET CUP
For IC Installations:
For Non-IC Installations:
CONVERTIBLE IC/NON-IC HOUSING
Remove the peel off label on the
outside of the housing section.
Remove the lower portion of
the ROUGH-IN LABEL as shown.
Non-IC rough-in sections are
listed for higher wattage lamps.
IC APPLICATIONS: REMOVE THIS
WARNING LABEL. SEE INSTRUCTION SHEET.
NON-IC APPLICATIONS:
WARNING - RISK OF FIRE.
DO NOT INSTALL INSULATION WITHIN 3
INCHES OF FIXTURE SIDE OR WIRING
COMPARTMENT NOR ABOVE FIXTURE IN
SUCH A MANNER TO ENTRAP HEAT.
ROUGH-IN LABEL
For suspended ceilings:
1. FRAME-IN (Fig. A)
• Rotate HINGED BAR ENDS to position shown and
fully extend bars.
Locate fixture along joist and line up bottom edge of HINGED
MOUNTING BAR with the bottom of joist and fasten in place.
• Crimp bottom of edge of CHANNEL to prevent
rotation of HINGED BAR ENDS.
• Bend NON-HINGED end of mounting bar at featured
hole location and extend out.
HINGED MOUNTING BAR
• Position notched area of MOUNTING BARS onto
T-BAR and lock by bending TAB underneath T-BAR
BEAD as shown.
T-BAR
HINGED BAR ENDS
CHANNEL
TAB
3” 1004IC
3 3/4” 1104IC
BEND AT HOLE
TAB
5 1/4” 1004IC
6 1/4” 1104IC
BEND TAB
TO LOCK
®