Lanier Printer Accessories 600 HP User Manual

Lanier Worldwide, Inc.  
2300 Parklake Dr., N. E.  
Atlanta, GA 30345-2979  
Emergency Telephone: (800)526-4371  
MATERIAL SAFETY DATA SHEET  
Section 1: Chemical Product and Company Information  
Identity:  
Product ID: 117- 0225  
MSDS No.  
Issued: 9/17/98  
Toner for 6113, 6213, 6413, 6514  
CP-300  
Supersedes:  
3/11/96  
Synonyms  
Toner, Black Toner for Lanier  
Date:  
9/17/98  
& Common M6113, 6213, 6413, 6514  
Names:  
Prepared by:  
Lanier QA/EH&S Department  
Uses:  
M6113, 6213, 6413, 6514 Copier  
European  
Contact:  
Lanier Worldwide, WSM Europe,  
Walter Fricke,  
Im Taubental D-41468 Neuss,  
Germany +49-2131-387-177  
Chemical  
Formula:  
Mixture, Inert resinated black  
powder  
Section 2: Composition / Information on Ingredients  
PERCENT  
85 ~ 90  
5 ~ 10  
1 ~ 5  
CAS No.  
25767-47-9  
1333-86-4  
9003-07-7  
102561-46-6  
7631-86-9  
EXPOSURE LIMITS  
not listed  
SOURCE  
n/a  
OSHA PEL ACGIH TLV  
Styrene-acrylic resin  
Carbon black  
Wax  
Organic pigment  
Silica  
3.5mg/m3 3.5mg/m3  
not listed  
not listed  
not listed  
n/a  
n/a  
n/a  
1 ~ 5  
< 1  
*PEL of the product: 15mg/m3 (total dust), 5mg/m3 (respirable dust)  
*TLV of the product: 10mg/m3 (total dust), 5mg/m3 (respirable dust)  
Section 3: Hazards Identification  
HMIS Rating:  
FLAMMABILITY = 0  
REACTIVITY = 0  
HEALTH = 0  
SPECIAL = none  
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-toxic dust. May  
cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.  
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner revealed there  
were no lung changes at all in the lowest exposure level (1mg/m3), the most relevant level to potential human exposures. A very slight degree of fibrosis was  
noted in 25% of the animals at the middle exposure level (4mg/m3), while a slight degree of fibrosis was observed at the highest exposure level (16mg/m3) in  
all animals. These findings are attributed to “Lung Overloading”, a generic response to excessive amount of any dust retained in the lungs for a prolonged  
interval. The special test toner was ten times more respirable than commercially available toner to comply with EPA testing protocol and would not function  
properly in xerographic equipment.  
Section 4: First Aid Measures  
Remove to fresh air if effects occur. Consult  
local medical personnel  
Inhalation:  
Eye Contact: In case of contact, immediately flush eyes with  
water for 5 minutes.  
Ingestion: Dilute stomach contents with water. Call a  
physician.  
Skin Contact:  
Wash with soap and water.  
Section 5: Fire Fighting Measures  
Suitable extinguishing media: CO2, dry chemical, foam or water.  
Extinguishing media which may not be used for safety reasons: none  
This material will burn in case of fire. The decomposition products are CO, CO2, and Nox. Avoid inhalation of smoke.  
Special protective equipment for fire fighters: none  
UEL: n/a  
LEL: n/a  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Lawn Mower ZSR54 ZSR60 User Manual
LevelOne Network Card WUA 0605 User Manual
LG Electronics Dehumidifier LHD45EL User Manual
LG Electronics DVD Player DVX692H User Manual
Linksys Network Card BEFDSR41W User Manual
Linksys Network Card EG0801SK User Manual
Lyngdorf Audio Stereo Amplifier SDAI 2175 User Manual
Magnavox CD Player AZ202517 User Manual
MB QUART Car Speaker PKC 110 User Manual
Mercedes Benz Automobile 2002 G 500 User Manual