LSI Life Jacket AP1172 E1 User Manual

Command Module and Drive  
Module  
Site Preparation Guide  
AP1172-E1, First Edition  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Compliance Statements  
FCC Radio Frequency Interference Statement  
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to  
Part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide  
reasonable protection against harmful interference in a commercial installation. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the  
instructions, may cause harmful interference to radio communications. Operation of this equipment in a  
residential area is likely to cause harmful interference, in which case the user will be required to correct the  
interference at his own expense.  
LSI Logic Corporation is not responsible for any radio or television interference caused by unauthorized  
modification of this equipment or the substitution or attachment of connecting cables and equipment other  
than those specified by LSI Logic Corporation. It is the users responsibility to correct interference caused by  
such unauthorized modification, substitution, or attachment.  
Laser Products Statement  
This equipment has been tested and found to comply with regulations for Class 1 laser product pursuant to  
21 CFR, Section 1040-10. For outside the USA, this equipment has been tested and found compliant with  
Class 1 laser product requirements contained in European Normalization standard EN 60825-1 1994+A11.  
Class 1 levels of laser radiation are not considered to be hazardous and are considered safe based upon  
current medical knowledge. This class includes all lasers or laser systems which cannot emit levels of optical  
radiation above the exposure limits for the eye under any exposure conditions inherent in the design of the  
laser product.  
LSI Logic Corporation is not responsible for any damage or injury caused by unauthorized modification of  
this equipment or the substitution or attachment of connecting cables and equipment other than those  
specified by LSI Logic Corporation. It is the users responsibility to correct interference caused by such  
unauthorized modification, substitution, or attachment.  
This Class A digital apparatus meets all requirements of the Canadian  
Interference-Causing Equipment Regulations.  
Cet appareil numérique de la classé A respecte toutes les exigences du  
Règlement sure le matèriel brouilleur du Canada.  
Command Module and Drive Module Site Preparation Guide  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Revision Record  
Edition or Revision  
Date  
Affected Pages or Remarks  
First Edition  
September 2002  
New Book.  
Part Number: AP1172-E1  
ii  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Command Module and Drive Module Site Preparation Guide  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Figures  
Command Module and Drive Module Site Preparation Guide  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
vi  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Tables  
Command Module and Drive Module Site Preparation Guide  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter  
1
72-Inch Cabinet Site Preparation  
This chapter contains essential site preparation information for the 72-inch cabinet that  
you will use to determine installation, service, and operating floor space requirements;  
heating and air conditioning specifications; and voltage and power requirements.  
Command Module and Drive Module Site Preparation Guide  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
72-Inch Cabinet Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Cabinet Features  
The rackmount cabinet (Figure 1-1) has a detachable back door and standard Electronic  
Industry Association (EIA) rails, which provide mounting holes for installing 19-inch wide  
devices. The cabinet has four roller casters and four adjustable guides (located beneath the  
cabinet) for moving and leveling the cabinet during installation and relocation. Newer  
models of this cabinet have interface cable access holes on the top and a removable stability  
foot that prevents the cabinet from tipping when it is moved.  
Standard  
EIA Rails  
Cable Access Holes  
(not available on all  
models)  
Roller Casters  
Empty Cabinet  
Removable Stability Foot  
(not available on all models)  
Populated Cabinet  
Figure 1-1 72-inch Cabinet  
1-2  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cabinet Features  
You can customize the cabinet to meet your data storage needs, based on performance,  
capacity, and availability requirements. The cabinet contains two AC power distribution  
boxes and can support a combination of twelve modules. The cabinet will ship with a  
maximum of three command modules installed.  
The command module is a rackmount unit containing two controllers, a battery,  
redundant cooling fans and power supplies.  
The array module may contain up to fourteen drives, redundant fans and power  
supplies, and two controllers.  
The drive module may contain up to fourteen drives, redundant fans and power  
supplies, and an Environmental Service Module (ESM).  
Command Module and Drive Module Site Preparation Guide  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
72-Inch Cabinet Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Area Requirements  
The floor area at the installation site must provide enough stability to support the weight  
of the cabinet and installed devices, sufficient space to install and service the cabinet and  
components, and sufficient ventilation to provide a free flow of air to the cabinet. Airflow  
in the cabinet is from the front to back. See Figure 1-2 for more information.  
Figure 1-2 Cabinet Area Requirements  
1-4  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Area Requirements  
Weights  
The total weight depends on the type and quantity of modules installed in the cabinet.  
Table 1-1 lists the overall weight of the cabinet, plus the maximum weight for each module.  
Use these weights to estimate the total weight of your system, based on the number of  
modules installed in the cabinet.  
Table 1-1 Cabinet, Crate, and Module Weights  
Cabinets and Modules  
Unit Weight  
Cabinet  
Empty  
Empty  
123.0 kg (270.0 lb)  
Pallet and Packaging1  
98.0 kg (215.0 lb)  
50.8 kg (112 lb)  
E2400 10x Array Module  
Deskside, Low Profile (LP) drives2  
Maximum  
E2400 10x Array Module  
Deskside, Half Height (HH) drives3  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
Maximum  
54.4 kg (120.0 lb)  
38.9 kg (86.4 lb)  
42.3 kg (94.0 lb)  
52.84 kg (116.5 lb)  
40.95 kg (90.5 lb)  
44.5 kg (98.0 lb)  
47.8 kg (105.0 lb)  
38.3 kg (84.4 lb)  
41.7 kg (92.0 lb)  
40.95 kg (90.5 lb)  
30.87 kg (68 lb)  
E2400 10x Array Module  
Rackmount, LP drives  
E2400 10x Array Module  
Rackmount, HH drives  
E2400 14x Array Module  
Deskside, LP drives  
E2400 14x Array Module  
Rackmount, LP drives  
FC-1 10x Drive Module  
Deskside, LP drives  
FC-1 10x Drive Module  
Deskside, HH drives  
FC-1 10x Drive Module  
Rackmount, LP drives  
FC-1 10x Drive Module  
Deskside, HH drives  
FC-1 14x Drive Module  
Rackmount, LP drives  
FC-2 14x Drive Module  
Rackmount, LP drives  
E4400 Command Module  
Maximum  
Maximum  
55.6 kg (122.3 lb)  
43.99 kg (97.0 lb)  
E4600 or E5600 Command Module  
1
Add for international shipments only  
2
Low-Profile drives  
3
Half-Height drives  
Command Module and Drive Module Site Preparation Guide  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
72-Inch Cabinet Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dimensions  
The cabinet has the following dimensions (Figure 1-3), excluding the removable stability  
foot:  
Height – 183 cm (72 in.)  
Width 56 cm (22 in.)  
Depth 91 cm (36 in.)  
Figure 1-3 Cabinet Dimensions  
1-6  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Requirements  
Environmental Requirements  
The cabinet is designed to operate in the environment defined in Table 1-2.  
Table 1-2 Cabinet Environmental Requirements  
Environment  
Altitude  
Requirements  
Operating Range  
Storage Range  
Transit Range  
Below Sea Level  
Above Sea Level  
Temperature  
30.5 m (100 ft.)  
30.5 m (100 ft.)  
30.5 m (100 ft.)  
3048 m  
(10,000 ft.)  
3048 m  
(10,000 ft.)  
12,000 m  
(40,000 ft.)  
Operating Range  
Storage Range  
Transit Range  
Temperature  
Range  
10° C to 35° C  
(50° F to 104° F)  
-10° C to 65° C  
(140° F to 149° F)  
-40° to 65° C  
(-40° F to 149° F)  
Temperature  
Change  
10° C per hour  
(21° F per hour)  
15° C per hour  
(31° F per hour)  
20° C per hour  
(42° F per hour)  
Relative Humidity  
No Condensation  
Dew Point  
Operating Range  
Storage Range  
Transit Range  
Maximum Allowed  
20% to 80%  
10% to 90%  
5% to 95%  
28° C (82° F)  
10% per hour  
Humidity Gradient  
Noise  
Steady/Non-Steady  
6.8 bels  
Configuration A1  
Normal Operation  
65 dBA  
Level  
Configuration B1  
Configuration C1  
Component  
1.62 kVA  
1601 W  
5467 Btu/hr  
3.23 kVA  
3202 W  
10,934 Btu/hr  
2.90 kVA  
2866 W  
9788 Btu/hr  
LP Drives2  
Heat Dissipation1  
1.69 kVA  
1677 W  
3.39 kVA  
3354 W  
3.02 kVA  
2988 W  
HH Drives2  
5727 Btu/hr  
11,454 Btu/hr  
10,205 Btu/hr  
1
These are kVA, W, and Btu calculations for three configurations containing Low-Profile (LP) and Half-Height (HH)  
drives, including:  
Configuration A contains 1 command module and 5 drive modules  
Configuration B contains 2 command modules and 10 drive modules  
Configuration C contains 3 command modules and 8 drive modules  
2
LP drives are 1.0 inch tall; HH drives are 1.6 inches tall.  
Command Module and Drive Module Site Preparation Guide  
1-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
72-Inch Cabinet Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Power Requirements  
This section provides information regarding power requirements, AC power distribution  
box specifications, ladder cord and power cord routing instructions, and site wiring  
conditions.  
The AC power source must provide the correct voltage, current, and frequency specified  
on the manufacturers nameplate. Table 1-3 shows the internal AC power requirements for  
rackmount cabinets.  
Table 1-3 Power Requirements  
Unit/Component  
Requirements  
Domestic  
250 VAC, 30 A  
International  
230 VAC, 32 A  
AC Power  
AC Plug  
NEMA L6-30P, locking plug  
6-30R, receptacle  
IEC 309 locking plug  
IEC 309 receptacle  
Receptacle  
Circuit Breaker  
Voltage Range  
Frequency  
25 A  
180 to 257 VAC  
49 to 50.5 Hz or 59 to 60.6 Hz  
220 VAC, 50/60 Hz  
Current  
(specified frequency)  
Configuration A1  
Configuration B1 Configuration C1  
LP Drives2  
7.35 A  
14.70 A  
13.16 A  
Operational Current  
HH Drives2  
LP Drives  
7.70 A  
10.95 A  
11.45 A  
15.40 A  
21.90 A  
22.90 A  
13.72 A  
22.20 A  
23.00 A  
Surge Current  
HH Drives  
1
Power specifications for three configurations containing Low-Profile (LP) and Half-Height (HH) drives, including:  
Configuration A contains 1 command module and 5 drive modules  
Configuration B contains 2 command modules and 10 drive modules  
Configuration C contains 3 command modules and 8 drive modules  
2
LP drives are 1.0 inch tall; HH drives are 1.6 inches tall.  
1-8  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
AC Power Distribution Boxes  
The cabinet has two identical AC power distribution boxes with two separate power cords  
(Figure 1-4). Depending on the configuration ordered, each box supports either domestic  
or international units and includes the following features:  
One domestic plug (NEMA L6-30P, 30 A, 220 VAC) or one international plug  
(IEC 309, 32 A, 3-pin, 230 VAC)  
One circuit breaker (25 A)  
Two power outlets (IEC 320, 16 A, C-19, filtered individually for international and  
domestic EMC compliance)  
Support for up to 12 attachments per box (24 per cabinet) using two ladder cables  
AC Power  
Distribution Boxes  
AC Power Distribution Box  
Power Cords  
Figure 1-4 Cabinet AC Distribution  
Command Module and Drive Module Site Preparation Guide  
1-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
72-Inch Cabinet Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Ladder Cords  
Each AC power distribution box outlet supports one ladder cord (Figure 1-5) that you can  
connect to a maximum of six modules. You may connect up to twelve 220/230 VAC  
modules to each AC power distribution box for a maximum of twenty-four power  
attachments inside the cabinet.  
Although the cabinet may not be fully populated when shipped, the cabinet is shipped with  
two ladder cords. Each cord has the following specifications:  
Cord 10 A per cord (1.67 A per connection if all are used)  
Input Connector IEC 320, C-19, 16 A, 250 VAC  
Plugs IEC 320, C-14, 10 A, 250 VAC  
Ladder Step 5.25 inches between connections  
Cord Routing Route cords between the mounting rails and side skins of cabinet  
Figure 1-5 Cabinet Ladder Cord  
1-10  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
Power Cords and Receptacles  
The cabinet is shipped with two power cords: one for domestic (inside USA) use, the other  
for international (outside USA) use. Each power cord connects to an independent 25 A  
circuit breaker and an AC power distribution box. The AC power distribution box has two  
outlets for connecting the power cords from modules installed in the cabinet to an  
independent power source outside of the cabinet. Figure 1-6 shows these receptacles.  
250 VAC, 16 A, IEC 320-C19 Cord  
From AC Power  
Distribution Box  
Independent  
External  
Power Source  
250 VAC, 30 A, NEMA L6-30 Cord  
(Domestic)  
230 VAC, 32 A, IEC 309 Cord  
(International)  
Figure 1-6 Types of 72-Inch Cabinet Power Cords and Receptacles  
Command Module and Drive Module Site Preparation Guide  
1-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
72-Inch Cabinet Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Site Wiring  
The cabinets AC power distribution boxes use common industrial wiring. Consider the  
following information when preparing the cabinet installation site:  
AC power source The AC power source must provide the correct voltage, current, and  
frequency specified on the manufacturers nameplate.  
Earth ground You must have an earth grounding conductor to the cabinets power  
receptacles.  
Circuit overloading Ensure the power circuits and associated circuit breakers provide  
sufficient power and overload protection. To prevent possible damage to the AC power  
distribution boxes and other components in the cabinet, use an external, independent  
power source which is isolated from large switching loads (such as air conditioning  
motors, elevator motors, and factory loads).  
Module power distribution There are two accessory outlets inside the cabinet for  
module power distribution. All units attached to these outlets must be auto-ranging  
between 180 through 257 VAC, 50-60 Hz.  
Power interruptions The cabinet and its modules will withstand the following  
applied voltage interruptions (with or without an integrated UPS):  
Input transient 50% of nominal voltage  
Duration one half cycle  
Maximum frequency once every ten seconds  
Power failures After a total power failure, the modules within the cabinet will  
automatically perform a power-up recovery without operator intervention after power  
is restored.  
1-12  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter  
2
Command Module Site Preparation  
This chapter provides technical specifications and information you will need to prepare a  
site before installing the E4400, E4600, and the E5600 command modules. This chapter  
provides information you will use to determine installation, service, and operating floor  
space requirements; heating and air conditioning specifications; voltage and power  
requirements; and adapter, module, transceiver, and cabling specifications for interface  
connectors.  
Command Module and Drive Module Site Preparation Guide  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Area Requirements  
The floor space at the installation site must provide enough strength to support the weight  
of the command module and associated equipment, sufficient space to install, operate, and  
service the command module, and sufficient ventilation to provide a free flow of air to the  
unit.  
Weights  
The total weight of the command module depends on the number of components installed  
Refer to Table 2-1, Table 2-2, and Table 2-3 for more information.  
Table 2-1 E4400 Command Module Weight  
1
3
Maximum  
Empty Unit  
2
2
Shipping  
Weight  
Shipping  
Weight  
Unit  
Unit Weight  
Unit Weight  
Rackmount Command  
Module  
43.99 kg (97.0 lb) 57.2 kg (125.9 lb) 16.1 kg (35.8 lb) 30.8 kg (67.8 lb)  
Battery  
9.7 kg (21.4 lb)  
3.0 kg (6.6 lb)  
0.9 kg (1.9 lb)  
1.5 kg (3.3 lb)  
11.8 kg (26.0 lb)  
5.0 kg (11.0 lb)  
2.3 kg (5.0 lb)  
2.9 kg (6.5 lb)  
Controller  
Controller Fan  
Power Supply  
Not applicable.  
Fan Communications  
Module  
1.84 kg (4.06 lb)  
2.46 kg (5.44 lb)  
GBIC Minihub  
0.567 kg (1.25 lb) 0.712 kg (1.57 lb)  
0.567 kg (1.25 lb) 0.712 kg (1.57 lb)  
DB-9 Minihub  
1
Maximum weight equals a command module with all canisters installed (fully loaded).  
Shipping weight equals the empty or maximum weight of the command module, plus all shipping materials.  
Empty weight equals a command module with all canisters removed.  
2
3
2-2  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Area Requirements  
Table 2-2 E4600 Command Module Weight  
1
3
Maximum  
Unit Weight  
Empty Unit  
2
2
Unit  
Rackmount  
Weight  
Shipping Weight  
Shipping Weight  
43.99 kg (97.0 lb) 57.2 kg (125.9 lb) 18.07 kg (39.84 lb)  
10.89 kg (24.0 lb) 12.97 kg (28.6 lb)  
30.8 kg (67.8 lb)  
Command Module  
Battery  
Controller  
3.0 kg (6.6 lb)  
0.9 kg (1.9 lb)  
1.5 kg (3.3 lb)  
5.0 kg (11.0 lb)  
2.3 kg (5.0 lb)  
2.9 kg (6.5 lb)  
Controller Fan  
Power Supply  
Not applicable.  
Fan Communications  
Module  
1.84 kg (4.06 lb)  
0.567 kg (1.25 lb)  
2.9 kg (6.3 lb)  
0.6 kg (1.5 lb)  
SFP Minihub  
1
Maximum weight equals a command module with all canisters installed (fully loaded).  
2
3
Shipping weight equals the empty or maximum weight of the command module, plus all shipping materials.  
Empty weight equals a command module with all canisters removed.  
Table 2-3 E5600 Command Module Weight  
1
3
Maximum  
Unit Weight  
Empty Unit  
2
2
Unit  
Weight  
Shipping Weight  
Shipping Weight  
Rackmount  
Command Module  
43.99 kg (97.0 lb) 57.2 kg (125.9 lb) 18.07 kg (39.84 lb)  
10.89 kg (24.0 lb) 12.97 kg (28.6 lb)  
30.8 kg (67.8 lb)  
Battery  
Controller  
3.0 kg (6.6 lb)  
0.9 kg (1.9 lb)  
1.5 kg (3.3 lb)  
5.0 kg (11.0 lb)  
2.3 kg (5.0 lb)  
2.9 kg (6.5 lb)  
Controller Fan  
Power Supply  
Not applicable.  
Fan Communications  
Module  
1.84 kg (4.06 lb)  
0.567 kg (1.25 lb)  
2.9 kg (6.3 lb)  
0.6 kg (1.5 lb)  
SFP Minihub  
1
Maximum weight equals a command module with all canisters installed (fully loaded).  
2
3
Shipping weight equals the empty or maximum weight of the command module, plus all shipping materials.  
Empty weight equals a command module with all canisters removed.  
Command Module and Drive Module Site Preparation Guide  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dimensions  
Command module dimensions are the same for each model (Figure 2-1).  
44.5 cm (17.5 in.)  
Rackmount  
17.5 cm (6.9 in.)  
61.0 cm (24.0 in.)  
48.2 cm (19.0 in.)  
2.0 cm (0.8 in.)  
Figure 2-1 Command Module Dimensions  
Shipping Carton Dimensions  
Shipping carton dimensions include the height of the pallet and are the same for all models  
(Table 2-4).  
Table 2-4 Command Module Shipping Carton Dimensions  
Carton Height  
Carton Width  
Carton Depth  
44.4 cm (17.5 in.)  
62.2 cm (24.5 in.)  
78.7 cm (31.0 in.)  
2-4  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Area Requirements  
Airflow  
For proper ventilation, allow at least 2 feet of clearance in front of and behind the  
command module (Figure 2-2).  
Back  
Front  
Figure 2-2 Command Module Airflow  
Command Module and Drive Module Site Preparation Guide  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Environmental Requirements  
The command module is designed to operate in the environment defined in Table 2-5 and  
Table 2-5 Command Module Environmental Requirements  
Requirement  
Condition  
Parameter  
E4400  
E4600  
E5600  
0° C to 43° C  
(32° F to 109° F)  
0° C to 40° C  
(32° F to 104° F)  
Operating Range  
10° C (18° F) per hour  
Maximum Rate of Change  
Storage Range  
-10° C to 65° C (14° F to 149° F)  
15° C (27° F) per hour  
Temperature  
Maximum Rate of Change  
-40° C to 60° C  
-40° C to 65° C  
(-40° F to 149° F)  
Transit Range  
(-40° F to 140°  
F)  
20° C (36° F) per hour  
20% to 80%  
10% to 93%  
Maximum Rate of Change  
Operating Range  
Storage Range  
10% to 90%  
Relative Humidity  
No condensation  
Transit Range  
5% to 95%  
26° C (79° F)  
10% per hour  
6.5 bels  
Maximum Dew Point  
Maximum Gradient  
Sound Power  
Sound  
Sound Pressure  
65 dBA  
3000 m (9840  
ft.)  
Operating and Storage  
Transit  
3048 (10,000 ft.)  
Altitude  
(Above Sea Level)1  
12,000 m (40,000 ft.)  
30.5 m (100 ft.)  
Altitude  
(Below Sea Level)  
Operating, Storage,  
and Transit  
1
If you plan to operate a command module at altitudes between 1000 m to 3000 m (3280 ft. to 9850 ft.) above sea level,  
lower the environmental temperature 1.7° C (3.3° F) for every 1000 m (3280 ft.) above sea level.  
2-6  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Requirements  
Table 2-6 Command Module Heat Dissipation  
Model  
E4400  
E4600  
E5600  
Heat Dissipation  
657.5 Btu/hr (0.1925 kVA or 192.5 W)  
790.0 Btu/hr (0.2333 kVA or 231.0 W)  
786.6 Btu/hr (0.2300 kVA or 230.0 W)  
Command Module and Drive Module Site Preparation Guide  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Power Requirements  
This section provides information regarding command module AC power requirements,  
power cord routing instructions, and site wiring conditions.  
The AC power source must provide the correct voltage, current, and frequency specified  
on the manufacturers nameplate. Internal AC power units for rackmount cabinets must  
be able to handle the power requirements for these units (Table 2-7).  
Table 2-7 Command Module Power Requirements  
Item  
Unit of Measure  
Slow-blow Fuse  
Nominal Voltage  
Frequency  
Requirement  
3 A per Power Supply  
90 to 264 VAC  
Circuit Breaker  
50 to 60 Hz  
AC Power  
1 A1  
2 A1  
Operating Current  
Maximum Surge Current  
1
Typical current at 240 VAC, 60 Hz at 0.70 power efficiency, 0.99 power factor.  
Power Cord Routing  
All modules are shipped with two AC power cords that are appropriate for use in a typical  
outlet in the destination country. Each power cord connects one of the power supplies in a  
module to an independent, external power source, such as a wall receptacle or  
uninterruptible power supply (UPS). If you have a rackmount cabinet with internal power  
cabling, such as a ladder cable, you do not need these power cords.  
A rackmount cabinet can have up to two AC power distribution boxes with separate power  
cords (Figure 2-3). To ensure redundancy, each power cord must connect to an  
independent, external power source. Each AC power distribution box has a ladder cable  
that runs up the inside of the cabinet and connects to one of the power supplies in each  
module.  
Figure 2-4 on page 2-10 shows the power cords and receptacles for domestic (inside USA)  
and international use (outside USA).  
2-8  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
Ladder Cord Connector  
Ladder Cord  
Command Module Power Supplies  
AC Power  
Distribution Boxes  
AC Power Distribution Box  
Power Cords  
Figure 2-3 Redundant Command Module AC Power Connections  
Command Module and Drive Module Site Preparation Guide  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
250 VAC, 16 A, IEC 320-C19 Cord  
From AC Power  
Distribution Box  
Independent  
External  
Power Source  
250 VAC, 30 A, NEMA L6-30 Cord  
(Domestic)  
230 VAC, 32 A, IEC 309 Cord  
(International)  
Figure 2-4 Types of 72-Inch Cabinet AC Power Cords and Receptacles  
2-10  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
Site Wiring  
The command module uses wide-ranging, redundant power supplies that automatically  
accommodate voltages to the AC power source. The power supplies operate at a range  
between 90 VAC and 264 VAC, and at a minimum frequency of 50 Hz and a maximum  
frequency of 60 Hz. The power supplies meet standard voltage requirements for both  
domestic (inside USA) and international (outside USA) operation. They use standard  
industrial wiring with line-to-neutral or line-to-line power connections.  
Consider the following information when preparing the command module installation  
site:  
Earth ground The unit must be properly grounded, including an earth ground  
conductor on the AC power source.  
Circuit overloading Ensure the power circuits and associated circuit breakers in the  
cabinet and building provide sufficient power and overload protection. To prevent  
possible damage to the unit, isolate its power source from large switching loads (such as  
air conditioning motors, elevator motors, and factory loads).  
Power interruptions The command modules will withstand the following applied  
voltage interruptions (with or without an integrated UPS):  
Input transient 50% of nominal voltage  
Duration one half cycle  
Frequency once every 10 seconds  
Power failures After a total power failure, the unit will automatically perform a  
power-up recovery sequence without operator intervention after power is restored.  
Command Module and Drive Module Site Preparation Guide  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Interface Cables and Connections  
This section provides information about command module interface cables, such as GBIC  
minihubs and SFP transceivers, and their appropriate connections. See Figure 2-5 and  
Figure 2-6 on page 2-14 for command module interface connector examples.  
E4400 Command Module  
The E4400 command module supports Fibre Channel connections to both hosts and drive  
modules. Up to four host minihubs and four drive minihubs, for a maximum of eight  
connections, can be installed in each command module. The E4400 supports two types of  
minihubs:  
GBIC minihub contains a pair of connectors for attaching either of the following:  
Optical GBIC module used with fiber optic cable  
Copper GBIC module used with copper fiber cable  
DB-9 minihub contains a pair of DB-9 connectors for attaching copper fiber cable  
Fiber Optic or  
Copper Fiber Cable  
GBIC Module  
Copper Fiber Cable  
DB-9 Connector  
Figure 2-5 Optical and Copper GBICs  
2-12  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interface Cables and Connections  
If you order optical GBIC connectors, you will need fiber optic cable. If you order copper  
GBIC minihubs or DB-9 minihubs, you will need copper fiber cable. Refer to Table 2-8 for  
types and cable lengths available from your local dealer.  
Table 2-8 E4400 Command Module Fibre Channel Interface Cables  
Descriptions  
Data Rate  
Order Information  
Part  
Transfer  
Speed  
Maximum  
Range  
Cable  
Length  
Number  
006-1086672  
006-1086416  
006-1086673  
006-1086417  
006-1086682  
006-1086672  
006-1086483  
006-1086473  
2 meter  
3 meter  
5 meter  
10 meter  
2 meter  
3 meter  
5 meter  
10 meter  
Fiber optic  
Multimode, 50micrometer,  
shortwave laser  
100 MB/s  
100 MB/s  
1062.5 Mb/s 0.5 kilometer  
Copper fiber  
Shielded, twisted pair,  
electrical signal  
1062.5 Mb/s  
30 meters  
Command Module and Drive Module Site Preparation Guide  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
E4600 and E5600 Command Modules  
The E4600 and E5600 command modules support fiber optic connections to both hosts  
and drive modules. Up to four host minihubs and four drive minihubs can be installed in a  
command module. Each Small Form-factor Pluggable (SFP) minihub has two connectors,  
allowing a maximum of sixteen connections. An SFP transceiver (Figure 2-6) attaches to  
one end of the fiber optic cable and plugs into the SFP minihub, which is connected to the  
command module. The other end of the cable connects to an optical GBIC module in the  
drive module.  
SFP Transceiver  
Fiber Optic Cable  
Figure 2-6 SFP Transceiver and Fiber Optic Cable  
Refer to Table 2-9 and Table 2-10 for interface connector cable lengths available from your  
local dealer.  
Table 2-9 E4600 Command Module Fibre Channel Host and Drive Interface Cables  
Descriptions  
Data Rate  
Order Information  
Transfer  
Speed  
Cable  
Maximum  
Part Number  
Length  
006-1086713  
006-1086714  
006-1086715  
006-1086716  
006-1086717  
006-1086718  
006-1086723  
006-1086724  
006-1086725  
006-1086726  
006-1086727  
006-1086728  
2 meter  
3 meter  
5 meter  
10 meter  
25 meter  
50 meter  
2 meter  
3 meter  
5 meter  
10 meter  
25 meter  
50 meter  
Fiber optic  
50/125UM LC/LC  
At least  
200 MB/s  
At least  
2125 Mb/s  
.03 kilometer  
Fiber optic  
50/125UM SC/LC  
100 MB/s  
1062.5 Mb/s 0.5 kilometer  
2-14  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interface Cables and Connections  
Table 2-10 E5600 Command Module Fibre Channel Host and Drive Interface Cables  
Descriptions  
Data Rate  
Order Information  
Transfer  
Speed  
Part  
Cable  
Maximum  
Length  
Number  
006-1086713  
006-1086714  
006-1086715  
006-1086716  
006-1086717  
006-1086718  
2 meter  
3 meter  
5 meter  
10 meter  
25 meter  
50 meter  
Fiber optic  
50/125 um LC/LC  
At least  
200 MB/s  
At least  
2125 Mb/s  
300  
kilometer  
Command Module and Drive Module Site Preparation Guide  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Command Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-16  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter  
3
Drive Module Site Preparation  
This chapter provides technical specifications and information you will need to prepare a  
site before installing a FC-1 10x, FC-1 14x, or FC-2 14x drive module. This chapter  
provides information you will use to determine installation, service, and operating floor  
space requirements; heating and air conditioning specifications; voltage and power  
requirements; and adapter, module, transceiver, and cabling specifications for interface  
connectors.  
Command Module and Drive Module Site Preparation Guide  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Area Requirements  
The floor space at the installation site must provide enough strength to support the weight  
of the drive module and associated equipment, sufficient space to install, operate, and  
service the drive module, and sufficient ventilation to provide a free flow of air to the unit.  
Weights  
The total weight of the drive module depends on the number of components installed  
Refer to Table 3-1, Table 3-2, and Table 3-3 for more information.  
Table 3-1 FC-1 10x Drive Module Weight  
Weight  
1
2
3
Unit  
Maximum Unit  
Empty Unit  
Shipping  
Drive Module  
Deskside Low Profile (LP) drives4  
44.5 kg (98.0 lb)  
23.6 kg (52.0 lb)  
59.0 kg (130.0 lb)  
Drive Module  
Deskside Half Height (HH) drives5  
47.8 kg (105.0 lb)  
38.3 kg (84.4 lb)  
41.7 kg (92.0 lb)  
23.6 kg (52.0 lb)  
12.7 kg (28.0 lb)  
12.7 kg (28.0 lb)  
62.4 kg (137.0 lb)  
43.5 kg (96.0 lb)  
47.0 kg (103.6 lb)  
Drive Module  
Rackmount LP drives  
Drive Module  
Rackmount HH drives  
LP Drive, 18 GB or 36 GB  
HH Drive, 36 GB or 73 GB  
ESM  
1.06 kg (2.34 lb)  
1.4 kg (3.08 lb)  
1.7 kg (3.8 lb)  
2.3 kg (5.0 lb)  
1.0 kg (2.3 lb)  
Not applicable.  
Power Supply  
Fan  
1
Maximum weight equals a drive module with all canisters installed (fully loaded).  
Empty weight equals a drive module with all canisters removed.  
2
3
4
5
Shipping weight equals the maximum weight of the drive module, plus all shipping material.  
Low-Profile drives.  
Half-Height drives.  
3-2  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Area Requirements  
Table 3-2 FC-1 14x Drive Module Weight  
Weight  
3
Unit  
Maximum Unit  
Shipping  
Drive Module  
Rackmount Low Profile (LP) drives  
40.95 kg (90.5 lb)1  
47.25 kg (105.0 lb)  
Drive Module  
Drive-ready Rackmount LP drives  
30.5 kg (66.4 lb)2  
37.44 kg (83.2 lb)  
LP Drive, 18 GB or 36 GB  
LP Drive, Blank Canisters  
ESM  
1.0 kg (2.2 lb)  
0.32 kg (0.72 lb)  
1.67 kg (3.7 lb)  
2.49 kg (5.5 lb)  
1.0 kg (2.2 lb)  
Power Supply  
Fan  
1
Maximum weight equals a drive module with all canisters installed (fully loaded).  
2
3
Drive-ready weight equals a drive module with all canisters installed and blank drives (empty).  
Shipping weight equals the maximum or drive-ready weight of the drive module, plus all shipping material.  
Table 3-3 FC-2 14x Drive Module Weight  
Weight  
3
Unit  
Maximum Unit  
Shipping  
Drive Module  
Rackmount Low Profile (LP) drives  
41.77 kg (92 lb)1  
53.57 kg (118 lb)  
42.68 kg (94 lb)  
Drive Module  
Drive-ready Rackmount LP drives  
30.87 kg (68 lb)2  
LP Drive, 18 GB or 36 GB  
LP Drive, 73 GB  
LP Drive, Blank Canisters  
ESM  
1.0 kg (2.2 lb)  
1.12 kg (2.46 lb)  
0.32 kg (0.72 lb)  
1.59 kg (3.7 lb)  
2.45 kg (5.39 lb)  
1.01 kg (2.23 lb)  
0.78 kg (1.72 lb)  
2.04 kg (4.5 lb)  
3.56 kg (7.39 lb)  
1.92 kg (4.23 lb)  
Power Supply  
Fan  
1
Maximum weight equals a drive module with all canisters installed (fully loaded).  
2
3
Drive-ready weight equals a drive module with all canisters installed and blank drives (empty).  
Shipping weight equals the maximum or drive-ready weight of the drive module, plus all shipping material.  
Command Module and Drive Module Site Preparation Guide  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dimensions  
Drive module dimensions for each model differ slightly. See Figure 3-1 and Figure 3-2 for  
model descriptions.  
16.6 cm (6.5 in.)  
52.7 cm (20.7 in.)  
56.0 cm (22.0 in.)  
44.7 cm (17.6 in.)  
12.9 cm (5.08 in.)  
13.18 cm (5.2 in.)  
55.91 cm (22.0 in.)  
48.0 cm (18.9 in.)  
1.59 cm (0.625 in.)  
Figure 3-1 FC-1 10x Drive Module Dimensions  
3-4  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Area Requirements  
44.70 cm (17.60 in)  
59.74 cm (23.52 in.)  
12.9 cm  
(5.08 in.)  
13.23 cm  
(5.21 in.)  
56.13 cm (22.1 in.)  
48.18 cm (18.97 in.)  
3.63 cm (1.43 in.)  
Figure 3-2 FC-1 14x and FC-2 14x Drive Module Dimensions  
Shipping Carton Dimensions  
Shipping carton dimensions include the height of the pallet (Table 3-4).  
Table 3-4 Drive Module Shipping Carton Dimensions  
Model  
Carton Height  
Carton Width  
Carton Depth  
FC-1 10x  
FC-1 14x and FC-2 14x  
38.1 cm (15.0 in.)  
61.4 cm (24.0 in.)  
83.2 cm (32.7 in.)  
44.45 cm (17.5 in.) 62.23 cm (24.5 in.) 74.93 cm (29.5 in.)  
Command Module and Drive Module Site Preparation Guide  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Airflow  
For proper ventilation, allow at least 2 feet of clearance in front of and behind the drive  
module (Figure 3-3).  
Deskside  
Back  
Front  
Rackmount  
Figure 3-3 Drive Module Airflow  
3-6  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Requirements  
Environmental Requirements  
The drive module is designed to operate in the environment defined in Table 3-5 and  
Table 3-5 Drive Module Environmental Requirements  
Requirement  
Condition  
Parameter  
Operating Range  
FC-1 10x, FC-1 14x, and FC-2 14x  
10° C to 40° C (50° F to 104° F)  
10° C (18° F) per hour  
Maximum Rate of Change  
Storage Range  
-10° C to 50° C (14° F to 122° F)  
15° C (27° F) per hour  
Temperature  
Maximum Rate of Change  
Transit Range  
-40° C to 60° C (-40° F to 140° F)  
20° C (36° F) per hour  
20% to 80%  
Maximum Rate of Change  
Operating Range  
Storage Range  
10% to 90%  
Relative Humidity  
No condensation  
Transit Range  
5% to 95%  
26° C (79° F)  
10% per hour  
6.0 bels  
Maximum Dew Point  
Maximum Gradient  
Sound Power  
Sound  
Sound Pressure  
60 dBA  
Operating and Storage  
Transit  
3000 m (9840 ft.)  
12,000 m (40,000 ft.)  
Altitude  
(Above Sea Level)1  
Altitude  
(Below Sea Level)  
Operating, Storage, and Transit  
30.5 m (100 ft.)  
1
If you plan to operate a drive module at altitudes between 1000 m to 3000 m (3280 ft. to 9850 ft.) above sea level,  
lower the environmental temperature 1.7° C (3.3° F) for every 1000 m (3280 ft.) above sea level.  
Table 3-6 Drive Module Heat Dissipation  
Low Profile (LP)  
18 GB and 36 GB Drives  
Half Height (HH)  
36 GB and 73 GB Drives  
Model  
FC-1 10x  
1036 Btu/hr (0.306 kVA or 303 W)  
1050 Btu/hr (0.309 kVA or 306 W)  
1084 Btu/hr (0.320 kVA or 317 W)  
1070 Btu/hr (0.33 kVA or 313 W)  
Not applicable.  
FC-1 14x  
FC-2 14x  
Not applicable.  
Command Module and Drive Module Site Preparation Guide  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Power Requirements  
This section provides information regarding drive module AC power requirements, power  
cord routing instructions, and site wiring conditions.  
The AC power source must provide the correct voltage, current, and frequency specified  
on the manufacturers nameplate. Internal AC power units for rackmount cabinets must  
be able to handle the power requirements for these units. Refer to Table 3-7, Table 3-8, and  
Table 3-9 on page 3-9 for more information.  
Table 3-7 FC-1 10x Drive Module Power Requirements  
Item  
Unit of Measure  
Slow-blow Fuse  
Requirement  
Circuit Breaker  
10 A per Power Supply  
Low Range  
High Range  
198 to 264 VAC  
50 to 60 Hz  
Nominal Voltage  
Frequency  
90 to 136 VAC  
50 to 60 Hz  
3.02 A  
1.31 A1  
1.34 A1  
AC Power  
Idle Current  
Maximum Operating Current  
3.11 A  
4.70 A  
Maximum Surge Current  
(10-drive spin up)  
1.92 A1  
1
Typical current: 240 VAC, 60 Hz at 0.70 power efficiency, 0.99 power factor.  
Table 3-8 FC-1 14x Drive Module Power Requirements  
Item  
Unit of Measure  
Slow-blow Fuse  
Requirement  
10 A per Power Supply  
Circuit Breaker  
Low Range  
High Range  
198 to 264 VAC  
50 to 60 Hz  
Nominal Voltage  
Frequency  
90 to 136 VAC  
50 to 60 Hz  
2.95 A1  
3.03 A1  
1.42 A2  
1.46 A2  
Idle Current  
AC Power  
Maximum Operating Current  
Maximum Surge Current  
(14-drive spin up)  
4.28 A1  
1.97 A2  
1
Typical current: 115 V AC, 60 Hz at 0.72 power efficiency, 0.99 power factor.  
Typical current: 230 V AC, 60 Hz at 0.72 power efficiency, 0.99 power factor.  
2
3-8  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
Table 3-9 FC-2 14x Drive Module Power Requirements  
Item  
Unit of Measure  
Requirement  
Circuit Breaker Slow-blow Fuse  
10 A per Power Supply  
Low Range  
High Range  
198 to 264 VAC  
50 to 60 Hz  
Nominal Voltage  
Frequency  
90 to 136 VAC  
50 to 60 Hz  
AC Power  
2.93 A1  
3.18 A1  
5.85 A1  
1.27 A2  
1.37 A2  
2.36 A2  
Idle Current  
Maximum Operating Current  
Maximum Surge Current  
1
2
Typical current: 100 V AC, 60 Hz at 0.73 power efficiency, 0.99 power factor.  
Typical current: 240 V AC, 60 Hz at 0.73 power efficiency, 0.99 power factor.  
Power Cord Routing  
All modules are shipped with two AC power cords that are appropriate for use in a typical  
outlet in the destination country. Each power cord connects one of the power supplies in a  
module to an independent, external power source, such as a wall receptacle or  
uninterruptible power supply (UPS). If you have a rackmount cabinet with internal power  
cabling, such as a ladder cable, you do not need these power cords.  
Typically, a rackmount cabinet has two AC power distribution boxes with separate power  
cords (Figure 3-4). To ensure redundancy, each power cord must connect to an  
independent, external power source. Each AC power distribution box has a ladder cable  
that runs up the inside of the cabinet and connects to one of the power supplies in each  
module.  
Figure 3-5 on page 3-11 shows the power cords and receptacles for domestic and  
international use.  
Command Module and Drive Module Site Preparation Guide  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Drive Module Power Supplies  
Ladder Cord Connector  
Ladder Cord  
AC Power  
Distribution Boxes  
AC Power Distribution Box  
Power Cords  
Figure 3-4 Redundant AC Power Connections to Drive Modules  
3-10  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
250 VAC, 16 A, IEC 320-C19 Cord  
From AC Power  
Distribution Box  
Independent  
External  
Power Source  
250 VAC, 30 A, NEMA L6-30 Cord  
(Domestic)  
230 VAC, 32 A, IEC 309 Cord  
(International)  
Figure 3-5 Types of 72-Inch Cabinet AC Power Cords and Receptacles  
Command Module and Drive Module Site Preparation Guide  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Site Wiring  
The drive modules use wide-ranging, redundant power supplies that automatically  
accommodate voltages to the AC power source. The power supplies operate at a range  
between 90 VAC and 264 VAC, and at a minimum frequency of 50 Hz and a maximum  
frequency of 60 Hz. The power supplies meet standard voltage requirements for both  
domestic (inside USA) and international (outside USA) operation. They use standard  
industrial wiring with line-to-neutral or line-to-line power connections.  
Consider the following information when preparing the drive module installation site:  
Earth ground The unit must be properly grounded, including an earth ground  
conductor on the AC power source.  
Circuit overloading Ensure the power circuits and associated circuit breakers in the  
cabinet and building provide sufficient power and overload protection. To prevent  
possible damage to the unit, isolate its power source from large switching loads (such as  
air conditioning motors, elevator motors, and factory loads).  
Power interruptions The drive modules will withstand the following applied voltage  
interruptions (with or without an integrated UPS):  
Input transient 50% of nominal voltage  
Duration one half cycle  
Frequency once every 10 seconds  
Power failures After a total power failure, the unit will automatically perform a  
power-up recovery sequence without operator intervention after power is restored.  
3-12  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interface Cables and Connections  
Interface Cables and Connections  
This section provides information about drive module interface cables, such as GBIC  
modules and SFP transceivers, and their appropriate connections.  
FC-1 10x and FC-1 14x Drive Modules  
The FC-1 10x and FC-1 14x drive modules support Fibre Channel connections to  
command modules. Each have four GBIC modules; two on each ESM (Figure 3-6). The  
modules may be fiber optic or copper. The module type depends on what type of drive  
interface you ordered and what type of cable you will be using to attach the drive module  
to the command module.  
Copper Fiber Drive  
Interface Cable  
Fiber Optic Host  
Interface Cable  
Optical GBIC Module  
Copper GBIC Module  
Figure 3-6 Optical and Copper GBICs  
Command Module and Drive Module Site Preparation Guide  
3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
If you order optical GBIC modules, you will need fiber optic cable. If you order copper  
GBIC modules, you will need copper fiber cable. Refer to Table 3-10 for types and cable  
lengths available from your local dealer.  
Table 3-10 FC-1 10x and FC-1 14x Drive Module Fibre Channel Interface Cables  
Descriptions  
Data Rate  
Order Information  
Part  
Transfer  
Speed  
Maximum  
Range  
Cable  
Length  
Number  
006-1086672  
006-1086416  
006-1086673  
006-1086417  
006-1086682  
006-1086672  
006-1086483  
006-1086473  
006-1086723  
006-1086724  
006-1086725  
006-1086726  
006-1086727  
006-1086728  
2 meter  
3 meter  
5 meter  
10 meter  
2 meter  
3 meter  
5 meter  
10 meter  
2 meter  
3 meter  
5 meter  
10 meter  
25 meter  
50 meter  
Fiber optic  
Multi-mode, 50 micrometer,  
shortwave laser  
0.5  
kilometer  
100 MB/s  
100 MB/s  
1062.5 Mb/s  
1062.5 Mb/s  
Copper fiber  
Shielded, twisted pair,  
electrical signal  
30 meters  
Fiber optic  
50/125UM SC/LC  
0.5  
kilometer  
100 MB/s  
1062.5 Mb/s  
3-14  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interface Cables and Connections  
FC-2 14x Drive Module  
The FC-2 14x drive module supports Fibre Channel connections to command modules.  
The drive module ships with two ESMs, and each has connectors for two optical Small  
Form-factor Pluggable (SFP) transceivers (Figure 3-7).  
SFP Transceiver  
Fiber Optic Cable  
Figure 3-7 SFP Transceiver and Fiber Optic Cable  
You will need to order fibre optic cable to connect the modules. Refer to Table 3-11 for  
interface connector cable lengths available from your local dealer.  
Table 3-11 FC-2 14x Drive Module Fibre Channel Interface Cables  
Descriptions  
Data Rate  
Order Information  
Part  
Transfer  
Speed  
Maximum  
Range  
Cable  
Length  
Number  
006-1086713  
006-1086714  
006-1086715  
006-1086716  
2 meter  
3 meter  
5 meter  
10 meter  
Fiber optic  
50/125UM LC/LC  
At least  
200 MB/s  
At least  
2125 Mb/s  
0.3 kilometer  
Command Module and Drive Module Site Preparation Guide  
3-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Drive Module Site Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-16  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter  
4
Array Module Site Preparation  
This chapter provides technical specifications and information you will need to prepare a  
site before installing the E2400 10x and E2400 14x array modules. This chapter provides  
information you will use to determine installation, service, and operating floor space  
requirements; heating and air conditioning specifications; voltage and power  
requirements; and adapter, module, transceiver, and cabling specifications for interface  
connectors.  
Command Module and Drive Module Site Preparation Guide  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Array Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Area Requirements  
The floor space at the installation site must provide enough strength to support the weight  
of the array module and associated equipment, sufficient space to install, operate, and  
service the array module, and sufficient ventilation to provide a free flow of air to the unit.  
Weights  
The total weight of the array module depends on the number of components installed.  
Refer to Table 4-1 and Table 4-2 for more information.  
Table 4-1 E2400 10x Array Module Weight  
Weight  
1
2
3
Unit  
Maximum Unit  
Empty Unit  
Shipping  
Array Module  
Deskside, Low Profile (LP) drives  
50.8 kg (112 lb)  
23.6 kg (52.0 lb)  
23.6 kg (52.0 lb)  
17.8 kg (39.2 lb)  
17.8 kg (39.2 lb)  
59.0 kg (130.1 lb)  
62.6 kg (138.1 lb)  
44.1 kg (98.0 lb)  
47.5 kg (105.6 lb)  
Array Module  
Deskside, Half Height (HH) drives  
54.4 kg (120.0 lb)  
38.9 kg (86.4 lb)  
42.3 kg (94.0 lb)  
Array Module  
Rackmount, LP drives  
Array Module  
Rackmount, HH drives  
LP Drive, 18 GB or 36 GB  
HH Drive, 36 GB or 73 GB  
Controller  
1.06 kg (2.34 lb)  
1.4 kg (3.08 lb)  
2.2 kg (4.8 lb)  
2.3 kg (5.0 lb)  
1.0 kg (2.3 lb)  
Power Supply  
Fan  
1
Maximum weight equals an array module with all canisters installed (fully loaded).  
Empty weight equals an array module with all canisters removed.  
2
3
Shipping weight equals the maximum weight of the array module, plus all shipping materials.  
4-2  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Area Requirements  
Table 4-2 E2400 14x Array Module Weight  
Weight  
1
2
3
Unit  
Maximum Unit  
Empty Unit  
Shipping  
Array Module  
Deskside, Low Profile (LP) drives,  
18 GB or 36 GB  
52.84 kg (116.5 lb) 27.0 kg (59.54 lb)  
59.0 kg (130.1 lb)  
Array Module  
Rackmount, LP drives, 18 GB or 36 GB  
40.95 kg (90.5 lb) 15.21 kg (33.54 lb) 47.25 kg (105.0 lb)  
LP Drive, 18 GB or 36 GB  
Controller  
1.06 kg (2.34 lb)  
2.2 kg (4.8 lb)  
2.3 kg (5.0 lb)  
1.0 kg (2.3 lb)  
Power Supply  
Fan  
1
Maximum weight equals an array module with all canisters installed (fully loaded).  
Empty weight equals an array module with all canisters removed.  
2
3
Shipping weight equals the maximum weight of the array module, plus all shipping materials.  
Command Module and Drive Module Site Preparation Guide  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Array Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dimensions  
Array module dimensions for each model differ slightly. See Figure 4-1 and Figure 4-2 for  
model descriptions.  
16.6 cm (6.5 in.)  
52.7 cm (20.7 in.)  
56.0 cm (22.0 in.)  
44.7 cm (17.6 in.)  
12.9 cm (5.08 in.)  
13.18 cm (5.2 in.)  
55.91 cm (22.0 in.)  
48.0 cm (18.9 in.)  
1.59 cm (0.625 in.)  
Figure 4-1 E2400 10x Array Module Dimensions  
4-4  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Area Requirements  
16.6 cm (6.5 in.)  
52.7 cm (20.7 in.)  
56.0 cm (22.0 in.)  
44.70 cm (17.60 in.)  
59.74 cm (23.52 in.)  
12.9 cm (5.08 in.)  
13.23 cm (5.21 in.)  
56.13 cm (22.1 in.)  
48.18 cm (18.97 in.)  
3.63 cm (1.43 in.)  
Figure 4-2 E2400 14x Array Module Dimensions  
Shipping Carton Dimensions  
The shipping carton dimensions include the height of the pallet (Table 4-3).  
Table 4-3 Array Module Shipping Carton Dimensions  
Model  
Carton Height  
38.1 cm (15.0 in.)  
44.45 cm (17.5 in.)  
Carton Width  
Carton Depth  
E2400 10x  
E2400 14x  
61.4 cm (24.0 in.)  
83.2 cm (32.7 in.)  
62.23 cm (24.5 in.) 74.93 cm (29.5 in.)  
Command Module and Drive Module Site Preparation Guide  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Array Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Airflow  
For proper ventilation, allow at least 2 feet of clearance in front of and behind the array  
module (Figure 4-3).  
Deskside  
Back  
Front  
Rackmount  
Figure 4-3 Array Module Airflow  
4-6  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Requirements  
Environmental Requirements  
The array modules are designed to operate in the environment defined in Table 4-4 and  
Table 4-4 Array Module Environmental Requirements  
Requirement  
Condition  
Parameter  
Operating Range  
E2400 10x and E2400 14x  
10° C to 40° C (50° F to 104° F)  
10° C (18° F) per hour  
Maximum Rate of Change  
Storage Range  
-10° C to 50° C (14° F to 122° F)  
15° C (27° F) per hour  
Temperature  
Maximum Rate of Change  
Transit Range  
-40° C to 60° C (-40° F to 140° F)  
20° C (36° F) per hour  
20% to 80%  
Maximum Rate of Change  
Operating Range  
Storage Range  
10% to 90%  
Relative Humidity  
No condensation  
Transit Range  
5% to 95%  
26° C (79° F)  
10% per hour  
6.0 bels  
Maximum Dew Point  
Maximum Gradient  
Sound Power  
Sound  
Sound Pressure  
60 dBA  
Operating and Storage  
Transit  
3000 m (9840 ft.)  
12,000 m (40,000 ft.)  
Altitude  
(Above Sea Level)1  
Altitude  
Operating, Storage,  
and Transit  
30.5 m (100 ft.)  
(Below Sea Level)  
1
If you plan to operate an array module at altitudes between 1000 m to 3000 m (3280 ft. to 9850 ft.) above sea level,  
lower the environmental temperature 1.7° C (3.3° F) for every 1000 m (3280 ft.) above sea level.  
Table 4-5 Array Module Heat Dissipation  
Low Profile (LP)  
18 GB and 36 GB Drives  
Half Height (HH)  
36 GB and 73 GB Drives  
Model  
E2400 10x  
E2400 14x  
1187 Btu/hr (0.35 kVA or 347 W)  
1118 Btu/hr (0.328 kVA or 327 W)  
1221 Btu/hr (0.37 kVA or 357 W)  
Not applicable.  
Command Module and Drive Module Site Preparation Guide  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Array Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Power Requirements  
This section provides information regarding array module AC power requirements, power  
cord routing instructions, and site wiring conditions.  
The AC power source must provide the correct voltage, current, and frequency specified  
on the manufacturers nameplate. Internal AC power units for rackmount cabinets must  
be able to handle the power specifications for these units. Refer to Table 4-6 and Table 4-7  
for more information.  
Table 4-6 E2400 10x Array Module Power Requirements  
Item  
Unit of Measure  
Slow-blow Fuse  
Requirement  
Circuit Breaker  
10 A per Power Supply  
Low Range  
High Range  
198 to 264 VAC  
50 to 60 Hz  
Nominal Voltage  
Frequency  
90 to 136 VAC  
50 to 60 Hz  
3.39 A  
1.45 A1  
1.50 A1  
AC Power  
Idle Current  
Maximum Operating Current  
3.53 A  
5.19 A  
Maximum Surge Current  
(10-drive spin up)  
2.10 A1  
1
Typical current at 240 VAC, 60 Hz at 0.70 power efficiency, 0.99 power factor.  
Table 4-7 E2400 14x Array Module Power Requirements  
Item  
Unit of Measure  
Slow-blow Fuse  
Requirement  
10 A per Power Supply  
Circuit Breaker  
Low Range  
High Range  
198 to 264 VAC  
50 to 60 Hz  
Nominal Voltage  
Frequency  
90 to 136 VAC  
50 to 60 Hz  
2.9 A1  
3.3 A1  
1.3 A2  
1.4 A2  
Idle Current  
AC Power  
Maximum Operating  
Current  
Maximum Surge Current  
(14-drive spin up)  
5.9 A1  
2.4 A2  
1
Typical voltage: 100 V AC, 60 Hz at 79% power supply efficiency and 0.99 power factor.  
Typical voltage: 240 V AC, 60 Hz at 81% power supply efficiency and 0.92 power factor.  
2
4-8  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
Power Cord Routing  
All modules are shipped with two AC power cords that are appropriate for use in a typical  
outlet in the destination country. Each power cord connects one of the power supplies in a  
module to an independent, external power source, such as a wall receptacle or  
uninterruptible power supply (UPS). If you have a rackmount cabinet with internal power  
cabling, such as a ladder cable, you do not need these power cords.  
Typically, a rackmount cabinet has two AC distribution boxes with two separate power  
cords (Figure 4-4). To ensure redundancy, each power cord must connect to an  
independent, external power source. Each AC distribution box has a ladder cable that runs  
up the inside of the cabinet and connects to one of the power supplies in each unit.  
Figure 4-5 shows the power cords and receptacles for domestic (inside USA) and  
international use (outside USA).  
Array Module Power Supplies  
Ladder Cable Connector  
Ladder Cable  
AC Power  
Distribution Boxes  
AC Power Distribution Box  
Power Cords  
Figure 4-4 Redundant AC Power Connections to Array Modules  
Command Module and Drive Module Site Preparation Guide  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Array Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
250 VAC, 16 A, IEC 320-C19 Cord  
From AC Power  
Distribution Box  
Independent  
External  
Power Source  
250 VAC, 30 A, NEMA L6-30 Cord  
(Domestic)  
230 VAC, 32 A, IEC 309 Cord  
(International)  
Figure 4-5 Types of 72-Inch Cabinet AC Power Cords and Receptacles  
4-10  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements  
Site Wiring  
The array modules use wide-ranging, redundant power supplies that automatically  
accommodate voltages to the AC power source. The power supplies operate at a range  
between 90 VAC and 264 VAC, and at a minimum frequency of 50 Hz and a maximum  
frequency of 60 Hz. The power supplies meet standard voltage requirements for both  
domestic (inside USA) and international (outside USA) operation. They use standard  
industrial wiring with line-to-neutral or line-to-line power connections.  
Consider the following information when preparing the array module installation site.  
Earth ground The unit must be properly grounded, including an earth ground  
conductor on the AC power source.  
Circuit overloading Ensure the power circuits and associated circuit breakers in the  
cabinet and building provide sufficient power and overload protection. To prevent  
possible damage to the unit, isolate its power source from large switching loads (such as  
air conditioning motors, elevator motors, and factory loads).  
Power interruptions The array modules will withstand the following applied voltage  
interruptions (with or without an integrated UPS):  
Input transient 50% of nominal voltage  
Duration one half cycle  
Frequency once every 10 seconds  
Power failures After a total power failure, the unit will automatically perform a  
power-up recovery sequence without operator intervention once power is restored.  
Command Module and Drive Module Site Preparation Guide  
4-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Array Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Interface Cables and Connections  
This section provides information about array module interface cables and their  
appropriate connections.  
The E2400 10x and E2400 14x array modules support Fibre Channel connections to drive  
modules. Each module has four GBIC connectors; two on each controller. The connectors  
may be fiber optic or copper (Figure 4-6). The connector type depends on what type of  
drive interface you order and what type of cable you will be using to attach the array  
module to the drive module.  
Copper  
Optical  
Figure 4-6 Optical and Copper GBICs  
4-12  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interface Cables and Connections  
If you order optical GBIC connectors, you will need fiber optic cable. If you order copper  
GBIC minihubs, you will need copper fiber cable. Refer to Table 4-8 for types and cable  
lengths available from your local dealer.  
Table 4-8 E2400 10x and E2400 14x Array Module Fibre Channel Interface Cables  
Descriptions  
Data Rate  
Order Information  
Part  
Transfer  
Speed  
Maximum  
Range  
Cable  
Length  
Number  
006-1086672  
006-1086416  
006-1086673  
006-1086417  
006-1086682  
006-1086672  
006-1086483  
006-1086473  
2 meter  
3 meter  
5 meter  
10 meter  
2 meter  
3 meter  
5 meter  
10 meter  
Fiber optic  
Multi-mode, 50 micrometer,  
shortwave laser  
100 MB/s  
100 MB/s  
1062.5 Mb/s 0.5 kilometer  
Copper fiber  
Shielded, twisted pair,  
electrical signal  
1062.5 Mb/s  
30 meters  
Command Module and Drive Module Site Preparation Guide  
4-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Array Module Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-14  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
A
D
array module  
data transfer rates 2-13, 3-14, 4-13  
area requirements 4-2  
dimensions  
dimensions 4-4  
array module 4-4  
environmental requirements 4-7  
heat dissipation 4-7  
cabinet 1-6  
command module 2-4  
drive module 3-4  
interface connections 4-12  
power cord routing 4-9  
power requirements 4-8  
site wiring requirements 4-11  
weight 4-2  
drive module  
area requirements 3-2  
dimensions 3-4  
environmental requirements 3-7  
heat dissipation 3-7  
interface connections 3-13  
power cord routing 3-9  
power requirements 3-8  
site wiring requirements 3-12  
weight 3-2  
C
cabinet  
area requirements 1-4  
dimensions 1-6  
environmental requirements 1-7  
features 1-2  
E
ladder cords 1-10  
power cords and receptacles 1-11  
power requirements 1-8  
site wiring requirements 1-12  
weight 1-5  
environmental requirements  
array module 4-7  
cabinet 1-7  
command module 2-6  
drive module 3-7  
E2400 10x  
cable  
copper fiber 2-13, 3-14, 4-13  
fiber optic 2-13, 2-14, 2-15, 3-14, 3-15, 4-13  
command module  
dimensions 4-4  
environmental requirements 4-7  
heat dissipation 4-7  
interface connections 4-12  
weight 4-2  
area requirements 2-2  
dimensions 2-4  
environmental requirements 2-6  
interface connections 2-12  
power cord routing 2-8  
power requirements 2-8  
site wiring requirements 2-11  
weight 2-2  
E2400 14x  
dimensions 4-5  
environmental requirements 4-7  
heat dissipation 4-7  
interface connections 4-12  
power requirements 4-8  
weight 4-3  
E4400  
dimensions 2-4  
environmental requirements 2-6  
interface connections 2-12  
power requirements 2-8  
weight 2-2  
Command Module and Drive Module Site Preparation Guide  
Index-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E4600  
dimensions 2-4  
M
environmental requirements 2-6  
interface connections 2-14  
power requirements 2-8  
weight 2-3  
multi-mode cable 2-13, 3-14, 4-13  
O
E5600  
optical, fiber interface 2-13, 2-14, 3-14, 3-15,  
dimensions 2-4  
environmental requirements 2-6  
interface connections 2-14  
power requirements 2-8  
weight 2-3  
P
power cord routing  
array module 4-9  
command module 2-8  
drive module 3-9  
power requirements  
array module 4-8  
cabinet 1-8  
F
FC-1 10x  
dimensions 3-4  
environmental requirements 3-7  
heat dissipation 3-7  
interface connections 3-13  
power requirements 3-8  
weight 3-2  
command module 2-8  
drive module 3-8  
FC-1 14x  
S
dimensions 3-5  
shortwave laser 2-13, 3-14, 4-13  
site wiring requirements  
array module 4-11  
cabinet 1-12  
environmental requirements 3-7  
heat dissipation 3-7  
interface connections 3-13  
power requirements 3-8  
weight 3-3  
command module 2-11  
drive module 3-12  
FC-2 14x  
dimensions 3-5  
environmental requirements 3-7  
heat dissipation 3-7  
interface connections 3-15  
power requirements 3-9  
weight 3-3  
U
uninterruptible power supply (UPS) 2-8, 3-9,  
W
weight  
I
array module 4-2  
cabinet 1-5  
command module 2-2  
drive module 3-2  
interface connections  
array module 4-12  
command module 2-12  
drive module 3-13  
L
ladder cords, cabinet 1-10  
Index-2  
Command Module and Drive Module Site Preparation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lenmar Enterprises Camera Accessories Digital Camera Battery User Manual
Lenoxx Electronics CD Player CD 857 User Manual
LG Electronics Home Theater Server PCS200R User Manual
Linksys Telephone SPA922 User Manual
Listen Technologies Carrying Case LA 331 User Manual
Macrom Stereo Amplifier 4405 User Manual
Magnavox CRT Television 13MT1432 17 13MT1433 17 User Manual
Maytag Cooktop AKT3040 User Manual
Metrologic Instruments Barcode Reader SP5600 User Manual
Microsoft Video Gaming Accessories 45X User Manual