OWNER’S MANUAL
MODEL Ardent™ 15M
PASSIVE MONITOR SPEAKER
Congratulations on the purchase of your new Kustom Ardent™ PA speaker. Being
both portable and powerful, your new Ardent™ speaker offers excellent sound quality
and performance characteristics. Inside this manual, you'll find detailed information
regarding this product's features. We wish you many years of enjoyment with your new
Kustom Ardent™ 15M.
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANTES INSTRUCTIONS DE SECURITE
FRENCH
1. Lire avec attention toutes les recommandations et précautions
d'emploi avant d'utiliser ce produit.
Danger
L‘exposition a des niveaux eleves de bruit peut provoquer
une perte permanente de l’audition, Chaque organisme
humain reagit differemment quant a la perte de l’audition,
mais quasiment tout le monde subit une diminution de
I’acuite auditive lors d’une exposition suffisamment
longue au bruit intense. Les autorites competentes en
reglementation de bruit ont defini les expositions tolerees
aux niveaux de bruits:
2. Toutes les recommandations et précautions d'emploi doivent
être conservées afin de pouvoir s'y reporter si nécessaire.
3. Lire et comprendre tous les avertissements énumérés dans les
précautions d'emploi.
4. Suivre toutes les précautions d'emploi pour utiliser ce produit.
5. Ce produit ne doit pas être utilisé près d'eau, comme par
exemple baignoires, éviers, piscine, sous-sol humides ... Etc.
6. Utiliser exclusivement un chiffon sec pour nettoyer ce produit.
7. Ne bloquér aucune ouverture de ventilation. Ne pas placer le
produit tout contre un mur ou dans une enceinte fernée, cela
gênerait le flux d'air nécessaire au refroidissement.
DURE EN HEURES PAR JOUR
8
6
4
3
2
1
8. Ne pas placer le produit près de toute source de chaeur telle
que radiateurs, arrivées d'air chaud, fourneaux ou autres
appareils générant de la chaleur (incluant les amplificateurs
producteurs de chaleur) .
INIVEAU SONORE CONTINU EN dB
90 93 95 97 100 103
Selon les autorites, toute exposition dans les limites
citees ci-dessus,peuvent provoquer certaines pertes
d’audition. Des bouchons ou protections dans l’appareil
auditif ou sur l’oreille doivent etre portes lors de
l’utilisation de ce systeme d’amplification afin de prevenir
le risque de perte permanente de l’audition, Dans le cas
d’expositions superieures aux limites precitees il est
recommande, afin de se premunir contre les expositions
aux pressions acoustiques eIevees potentielIement
dangeureuses, aux personnes exposees aux
9. Ne pas négliger la sécurité que procure un branchement
polarisé ou avec raccordement à la terre, Un branchement
polarisé comprend deux fiches dont l'une est plus large que
l'autre. Un branchement à la terre comprend deux fiches plus
une troisième reliée à la terre. Si la fiche secteur fournie ne
s'insert pas dans votre prise de courant. consulter un
'électricien afin de remplacer votre prise obsolète.
10. Protéger le cordon d'alimentation de tout écrasement ou
pincement, particulièrement au niveau des fiches, des
réceptacles utilisés et à l'endroit de sortie de l'appareil. Ne pas
casser la fiche de terre du cordon d'alimentation.
equipements capables de delivrer de telles puissances,
tels ce systeme d’amplification en fonctionnement, de
proteger l’appareil auditif.
11. Utiliser uniquement les accessoires spécifiés par le
constructeur.
12. Utiliser uniquement avec le chariot de
transport, le support, le trépied, la
console ou la table spécifiés par le
constructeur ou vendus avec l'appareil.
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR.
S3125A
Lors de l'utilisation d'un chariot, bouger
avec précaution l'ensemble chariotlappareil
afin d'éviter les dommages d'un renversement.
ATTENTION: AFIN DE LlMlTER LE RISQUE DE CHOC ELECTRIQUE,
NE PAS ENLEVER LE CHASSIS. NE CONTIENT PAS DE
PIECES POUVANT ETRE REPAREE PAR L’UTILISATEUR.
CONFIER LE SERVICE APRES-VENTE AUX
13. Débrancher cet appareil lors d'orages ou s'il n'est pas utilisé
pendant une longue période.
REPARATEURS AGREES.
14. Des précautions doivent être prises afin qu'aucun objet ne
tombe et qu'aucun liquide ne se répande à l'intérieur de
l'appareil par les orifics de ventilation ou n'importe quelle autre
ouverture.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
DE VOLTAGE DANGEREUX NON-ISOLE A L'INTERIEUR DE CE PRODUIT
QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR
PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES.
15. Pour toutes interventions techniques s'adresser à un
technicien qualifié.L'intervention technique est nécessaire
lorsque l'appareil a été endommagé de n'importe quelle façon,
comme par exemple si le cordon secteur ou sa fiche sont
détériorés,si du liquide a coulé ou si des objets sont tombés à
l'intérieur de l'apparei1,si l'appareil a été exposé à la pluie ou à
l'humidité, s'il ne fonctionne pas normalement ou s'il est tombé.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
D'INSTRUCTIONS D'UTILISATION ET DE MAINTENANCE DANS LES
DOCUMENTS FOURNIS AVEC CE PRODUIT.
AFIN DE REDUIRE LES RISQUÉ D'INCENDIE ET DE DECHARGE
ELECTRIQUE, NE PAS EXPOSER CET APPAREIL A LA PLUIE OU A
L'HUMIDITE.
16. ATTENTI0N:Pour réduire le risque d'incendie ou de choc
electrique ne pas exposer l'appareil à la pluie ou à l'humidité.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
BACK PANEL DIAGRAM
1This switch uses the internal matching transformer to select the impedance of your Ardent™
15M. It does not affect speakers plugged into jacks (c
d). NOTE: The speaker acoustical
output will drop 3dB when switched to 16 ohms. This is because the load on the amplifier
driving the Ardent™ 15M is ½ that of the 8 ohm setting.
2This Multi-position switch uses the internal matching transformer to attenuate (lower) the
volume of the Ardent™ 15M. It does not affect speakers plugged into jacks (c
reduces the amplifier load.
d). It also
3These 1/4” jacks are used to connect the speaker cabinet to an amplifier, such as a
powered mixer or power amp. These jacks are wired in parallel, so they can be used to
connect to another speaker cabinet.
4This jack accepts Neutrik Speakon® connector. Pins +1 and - 1 are used. This jack is also
wired in parallel with the 1/4” jacks (c).
Horn
Block Diagram
SpeakondJacks
Horn
Protection
+1
-1
Attenuator
Speaker
8 - 16 Ohm
Selector
1/4” Jacks
Crossover
+
-
4
Download from Www.Somanuals.com. All Manuals Search And Download.
TYPICAL SET UP
Impedance:
Impedance switch set to 8 ohms
Each monitor receives up to 150 watts.
Amplifier load = 4 ohm/Channel
Impedance switch set to 16 ohms
Each monitor receives up to 75 watts.
Amplifier load = 4 ohm/Channel
Amplifier Rating:
300W RMS into
4 ohm/Channel
Amplifier Rating:
300W into
4 ohm/Channel
CH-A
CH-B
CH-A
CH-B
16 Ohms
16 Ohms
8 Ohms
8 Ohms
8 Ohms
16 Ohms
16 Ohms
16 Ohms
16 Ohms
16 Ohms
Number of Monitors
x Impedance selected
8 Ohms
Amplifier load
16
8
1 x 16
1 x 8 or 2 x 16
1 x 8 and 1 x 16
2 x 8 or 4 x 16
2 x 8 and 1 x 16
3 x 8 or 6 x 16
4 x 8 or 8 x 16
5.33
4
3.2
2.67
2
16 Ohms
Chart to determine load on amplifier.
NOTE:
It is more efficient to use a two channel amplifier in combined/4 ohm mode with monitor impedance
set to 8 ohms, than in bridge/8 ohm and set to 16.
CAUTION:
Maximum input to one monitor cannot exceed 150W RMS/8 ohms (34.6VRMS) .
Do not load the amplifier to an impedance lower than recommended. Typically, this is 4 ohms.
Attenuation:
1Using the above diagram chart as reference, connect monitors to amplifier. Maximum input
to each monitor cannot exceed 150W RMS/8 ohms (34.6VRMS).
2Set attenuator on all monitors to 0 dB.
3Do a sound check to set volume to desired level.
4Use attenuator to lower volume on monitors that do not need to be as loud, or have
problems with feedback.
NOTE:
When an amplifier channel is used for driving only monitors with attenuators, it is best to
have at least one of them set to 0dB. If this cannot be achieved, set attenuator on the
monitor that needs to be loudest to 0 dB and adjust level on power amp input to make this
monitor the correct volume. Attenuate only monitors that do not need to be as loud.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Ardent 15M
Specifications
Model
Ardent 15M
150 Watt Passive Speaker
150 Watts / 300 Watts
Power Handling
RMS/Peak
12"
Speaker
Horn Type
Special Design
1"
Neodymium Compression Driver
Actual response may vary depending on input.
1 Watt / 1 Meter
Frequency Response
Sensitivity
45 - 18K
97dB
Impedance
8 -16 Ohm Selectable Nominal
Crossover Frequency
Dimensions
2.2 KHz
High Pass / Low Pass With Horn Protection Circuit
mm
Inches
kg
??? (Height) x ??? (Width) x ??? (Depth)
??? (Height) x ??? (Width) x ???? (Depth)
?? kg
Weight
SPL vs Freq
dBSPL
120
115
110
105
100
95
90
85
80
75
70
20 Hz
50
100
200
500
1K
2K
5K
10K
20K
Note: Kustom does not supply mounting hardware for Ardent™ speakers. For safety purposes, be sure to utilize
professional mounting procedures and materials for these, or any, speaker systems.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
EC Declaration of Conformity
We:
Kustom Musical Amplification Inc.
PO. Box 568
Hebron, Ky 41048-0568
Tel: 1-513-451-5000 Fax: 1-513-347-2192
Declare that the product
Product name:
Kustom
Product model number:
Ardent 15M
to which this declaration relates is in conformity with the following standards;
EN55013 (A12) : 1995
Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and
associated equipment.
EN55020: 1995
Electromagnetic immunity of broadcast receivers and associated equipment.
Limits for harmonic current emissions (equipment input current < 16A per phase).
EN61000-3-2: 1995
EN61000-3-3: 1995
Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with
rated currents < 16A.
EN55103-1: 1995
EN60065: 1994
Electromagnetic Compatibility - Product family standard for Audio, Video Audio-visual and
entertainment Lighting Control Apparatus.
Safety requirements for main operated electronic and related apparatus for household and similar
general use.
Following the provisions of EU Council Directive(s): 72/73 EEC and 89/336/EEC.
We the undersigned, hereby declare that the equipment specified above conforms to the aforementioned directive(s).
Name of authorized person: James Brown, Chief Engineer
Signature:______________________
Date: 07 May 2007
Kustom Amplification Inc.
PO. Box 568
Hebron, Ky 41048-0568
Tel: 1-513-451-5000 Fax: 1-513-347-2192
7
Download from Www.Somanuals.com. All Manuals Search And Download.
®
Kustom Amplification Inc., PO BOX 568, Hebron, KY • USA
Download from Www.Somanuals.com. All Manuals Search And Download.
|