Klark Teknik Stereo Equalizer DN9340E User Manual

DN9340E/DN9344E  
Digital Equaliser  
Operator Manual  
Klark Teknik,  
Klark Teknik Building,  
Walter Nash Road,  
Kidderminster.  
Worcestershire.  
DY11 7HJ.  
England.  
Tel: +44 (0) 1562 741515  
Fax: +44 (0) 1562 745371  
DN9340E/DN9344E HELIX Operator Manual  
DOC02-DN9340E/44E Issue B – August 2006  
© Telex Communications (UK) Limited.  
In line with the company’s policy of continual improvement, specifications and function may be  
subject to change without notice. This Operator Manual was correct at the time of writing. E&OE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
The lightning flash with arrowhead symbol within an equilateral triangle, is  
intended to alert the user to the presence of uninsulated “Dangerous Voltage”  
within the product's enclosure that may be of sufficient magnitude to constitute a  
risk of electric shock to persons.  
The exclamation point within an equilateral triangle, is intended to alert the user  
to the presence of important operating and maintenance (servicing) instructions  
in the literature accompanying the product.  
WARNING:  
WARNING:  
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS  
APPARATUS TO RAIN OR MOISTURE.  
DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPLASHING AND  
ENSURE THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, ARE  
PLACED ON THE EQUIPMENT.  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
Read these instructions.  
Keep these instructions.  
Heed all warnings.  
Follow all instructions.  
Do not use this apparatus near water.  
Clean only with a dry cloth.  
Do not block any of the ventilation openings. Install in accordance with the manufacturer’s  
instructions.  
8.  
9.  
Do not install near any heat sources such as radiators, heat registers, stoves, or other  
apparatus (including amplifiers) that produce heat.  
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has  
two blades with one wider than the other. A grounding type plug has two blades and a third  
grounding prong. The wide blade or the third prong are provided for your safety. If the  
provided plug does not fit into your outlet, consult an electrician for replacement of the  
obsolete outlet.  
10.  
Protect the power cord from being walked on or pinched particularly at plugs, convenience  
receptacles and the point where they exit from the apparatus.  
11.  
12.  
13.  
Only use attachments/accessories specified by the manufacturer.  
Unplug this apparatus during lightning storms or when unused for long periods of time.  
Refer all servicing to qualified personnel. Servicing is required when the apparatus has been  
damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or  
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture,  
does not operate normally, or has been dropped.  
14.  
15.  
Use the mains plug to disconnect the apparatus from the mains.  
The mains plug of the power supply cord shall remain readily operable.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telex Communications (UK) Limited, Klark Teknik Building,  
Walter Nash Road, Kidderminster. Worcs. DY11 7HJ. England.  
Tel: +44 1562 741515 Fax: +44 1562 745371  
DECLARATION OF CONFORMITY  
We,  
of,  
Telex Communications (UK) Limited  
Klark Teknik Building, Walter Nash Road, Kidderminster, Worcestershire, DY11 7HJ.  
Declare that a sample of the following product:-  
Product Type Number  
DN9340E  
Product Description  
Digital Equaliser  
Nominal Voltage(s)  
115V AC  
Current  
200mA  
100mA  
Freq  
50/60Hz  
DN9344E  
230V AC  
to which this declaration refers, is in conformity with the following directives and/or standards:-  
Directive(s)  
Test Standard(s)  
89/336/EEC Electromagnetic Compatibility Directive  
amended by 92/31/EEC & 93/68/EEC 73/23/EEC,  
Low Voltage Directive, amended by 93/68/EEC  
Generic Standard Using EN50130 Limits and Methods  
Class B Conducted Emissions  
Class B Radiated Emissions  
Fast Transient Bursts at 2kV  
Static Discharge at 4kV  
EN50081/1  
EN50130  
EN50130  
EN61000-4-4  
EN61000-4-2  
EN60204  
Electrical Stress Test  
Electrical Safety  
EN60065  
Signed:
Name: Simon Harrison  
Date: 29th March 2006  
Authority: Research and Development Director, Telex Communications (UK) Limited  
Attention!  
Where applicable, the attention of the specifier, purchaser, installer or user is drawn to  
special limitations of use which must be observed when these products are taken into  
service to maintain compliance with the above directives. Details of these special measures  
and limitations to use are available on request and are available in product manuals.  
Company registration No. 2414018. A Subsidiary of Telex Communications Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thank You For Using This Klark Teknik Product  
Our engineers have designed this product with uncompromising dedication to providing the superb  
audio performance, ease of use and rugged reliability that meets the demands of live sound  
engineering.  
Please take time to complete and return the Klark Teknik three-year warranty registration card and,  
to obtain maximum performance with minimum effort, refer to this operator’s manual. Please ensure  
that you read both the Important Safety Instructions and Attention! pages.  
Finally, enjoy your new DN9340E/DN9344E!  
CONTENTS  
ATTENTION! ......................................................................................... 1  
1.  
QUICK REFERENCE.....................................................................................3  
1.1. DN9340E Front Panel..................................................................................................3  
1.2. DN9344E Front Panel..................................................................................................4  
2.  
INTRODUCING THE DN9340E/DN9344E .........................................................5  
2.1. Host Software Versions ...............................................................................................5  
2.2. Key Features .............................................................................................................5  
3.  
FRONT PANEL: DN9340E............................................................................7  
3.1. EQ Access and Displays...............................................................................................7  
3.2. Bypass, Channel Select, Soft Keys and Alphanumeric Display ...........................................8  
3.3. Touch Strip, Store and Recall, Home (Setup) and Data Entry............................................9  
3.4. PC Port, Metering and Power...................................................................................... 10  
4.  
REAR PANEL: DN9340E ...........................................................................11  
SIGNAL FLOW: DN9340E .........................................................................12  
OPERATION: DN9340E ............................................................................13  
5.  
6.  
6.1. Home Page.............................................................................................................. 13  
6.1.1  
6.1.2  
6.1.3  
Home page sub-menus ....................................................................................... 13  
A/B Link ........................................................................................................... 13  
Touchstrip Operation on the Home Page................................................................ 14  
6.2. Graphic Equalisation................................................................................................. 15  
6.2.1  
6.2.2  
6.2.3  
Soft Key Functions ............................................................................................. 15  
Touchstrip operation with Graphic equalisation ....................................................... 17  
Grouping .......................................................................................................... 17  
6.3. Parametric Equalisation............................................................................................. 18  
6.3.1  
6.3.2  
Soft Key Functions ............................................................................................. 18  
Touchstrip operation with Parametric equalisation................................................... 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.4.  
6.4.1  
6.4.2  
Dynamic Equalisation .................................................................................. 20  
Soft Key Functions ............................................................................................. 20  
Touchstrip operation with Dynamic equalisation...................................................... 21  
6.5. Filters..................................................................................................................... 22  
6.5.1  
6.5.2  
6.5.3  
“Create Filter” function........................................................................................ 22  
Soft Key Functions ............................................................................................. 22  
Touchstrip operation with Filters........................................................................... 23  
6.6. Metering ................................................................................................................. 24  
6.7. Clear Down Sequence ............................................................................................... 25  
7.  
SETUP MENU: DN9340E ...........................................................................26  
7.1. General................................................................................................................... 26  
7.2. Comms channel (Page 1)........................................................................................... 27  
7.2.1  
7.2.2  
Remote control via a PC ...................................................................................... 27  
Using a DN9340E for master control...................................................................... 28  
7.3. Front Panel lock (Page 2)........................................................................................... 29  
7.4. Analogue/Digital Input Select (Page 3) ........................................................................ 30  
7.5. Digital Output Clock Select (Page 4)............................................................................ 31  
7.6. Presets lock (Page 5) ................................................................................................ 31  
7.7. LCD contrast adjustment (Page 6) .............................................................................. 32  
7.8. Naming (Pages 7 and 8)............................................................................................ 32  
7.9. Delay options (Page 9).............................................................................................. 32  
7.10. Power-up Logo (Page 10) .......................................................................................... 33  
7.11. Ethernet Settings (Pages 11 and 12)........................................................................... 33  
7.11.1 Ethernet IP Address (Page 11) ............................................................................. 33  
7.11.2 Ethernet Subnet Mask Setup (Page 12) ................................................................. 34  
8.  
9.  
STORING AND RECALLING SETTINGS: DN9340E...............................................35  
DN9340E AND DN9344E MASTER/SLAVE REMOTE CONTROL...............................36  
9.1. Connections............................................................................................................. 36  
9.2. Addresses ............................................................................................................... 36  
9.3. Data model ............................................................................................................. 36  
9.4. Getting started ........................................................................................................ 37  
9.5. Operation................................................................................................................ 38  
9.6. System naming........................................................................................................ 38  
9.7. Copy channel function............................................................................................... 39  
9.8. Solo Tracking operation............................................................................................. 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. DN9340E AND DN9344E REMOTE CONTROL SETUP .........................................40  
10.1. Overview ................................................................................................................ 40  
10.2. HELIX DN9340E/DN9344E unit interconnections ........................................................... 40  
10.2.1 Connecting the HELIX DN9340/DN9344E units in a daisy chain................................. 41  
10.2.2 Connecting the HELIX DN9340E/DN9344E units to an Ethernet switch or hub ............. 41  
10.3. Ethernet Connection ................................................................................................. 42  
10.3.1 Ethernet connection – standard............................................................................ 42  
10.3.2 Ethernet connection – wireless option ................................................................... 42  
10.3.3 Configuring the DN9340E for Network Communication............................................. 43  
10.3.4 Configuring the DN9344E for Network Communication............................................. 43  
10.4. Serial Connection (Option)......................................................................................... 44  
10.4.1 Serial connection details...................................................................................... 44  
10.4.2 Connection and Configuration Procedure................................................................ 44  
11. FRONT PANEL: DN9344E..........................................................................45  
11.1. Alphanumeric displays, SETUP, Metering and Power ...................................................... 45  
11.2. Indicators, Up and Down Buttons, PC Port and Scribble Strips......................................... 46  
12. REAR PANEL: DN9344E ...........................................................................47  
13. SIGNAL FLOW: DN9344E .........................................................................48  
14. OPERATION: DN9344E ............................................................................49  
15. SET UP MENU: DN9344E .........................................................................49  
15.1. General .................................................................................................................. 49  
15.2. Remote Comms channels (Page 1).............................................................................. 49  
15.3. Password Page (Page 2)............................................................................................ 52  
15.4. Analogue/Digital Input Select (Pages 3 and 4).............................................................. 52  
15.5. Digital Output Clock Select (Pages 5 and 6) ................................................................. 53  
15.6. Ethernet Settings (Page 7) ........................................................................................ 54  
15.6.2 Subnet Mask (Page 8)......................................................................................... 54  
16. APPLICATION NOTES.................................................................................55  
16.1.  
Dynamic EQ............................................................................................... 55  
16.2. What do we mean by all these Q types? ...................................................................... 58  
16.3. What is AES/EBU?.................................................................................................... 61  
17. TECHNICAL SPECIFICATION.........................................................................62  
17.1. DN9340E ................................................................................................................ 62  
17.2. DN9344E ................................................................................................................ 64  
18. SERVICE INFORMATION .............................................................................66  
18.1. Battery................................................................................................................... 66  
18.1.1 Replacement ..................................................................................................... 66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTENTION!  
Please ensure that you read and follow the  
IMPORTANT SAFETY INSTRUCTIONS at the front of this manual and the  
SAFETY WARNINGS and INSTALLATION CONSIDERATIONS given below.  
Safety Warning  
To prevent shock or fire hazard, do not expose the unit to rain or moisture. To avoid electrical shock  
do not remove covers. Refer servicing to qualified personnel only.  
This unit is fitted with a standard fused IEC mains power socket. The unit contains a switch mode  
power supply that automatically adjusts itself to 50/60Hz mains supplies in the 100V to 240V (±10%)  
AC range. This information is printed on the rear of the unit, adjacent to the mains inlet socket.  
Before connecting this unit to the mains supply, ensure that the fuse fitted is the correct type and  
rating as indicated on the rear panel.  
For safety reasons the mains earth lead should never be disconnected. In the event of ground loop  
problems, disconnect the signal screen at one end of the connecting cables – note that this can only  
be done when the unit is used within a balanced system.  
Installation Considerations  
Location:  
Do not install this unit in a location subjected to excessive heat, dust or  
mechanical vibration. Allow for adequate ventilation around the unit, making sure  
the unit’s fans and vents are not obstructed. To prevent excessive heating of the  
unit, avoid mounting the unit directly above power amplifiers or other devices  
that radiate significant amounts of heat. Where necessary, use fan cooled racks.  
Cables:  
To ensure correct and reliable performance, this product should only be used with  
high quality, screened twisted pair audio cables, terminated with metal-bodied  
3-pin XLR connectors (Pin 2 Hot).  
Electric Fields:  
Should this product be used in an electromagnetic field that is amplitude  
modulated by an audio frequency signal (20Hz to 20kHz), the signal to noise ratio  
may be degraded. Degradation of up to 60dB at a frequency corresponding to the  
modulation signal may be experienced under extreme conditions (3V/m, 90%  
modulation).  
After Unpacking  
Please retain the original packing for use should you need to transport or ship this unit.  
Please inspect the unit carefully for any signs of damage that may have occurred in transit and notify  
the courier immediately if you feel that any damage has occurred.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Reference  
1. QUICK REFERENCE  
1.1. DN9340E Front Panel  
2
3
4
5
1
7
8
9
10 11  
12  
13  
6
1
Access buttons  
EQ active LEDs  
Access buttons to control each type of equalisation –  
GRAPHIC, PARAMETRIC, DYNAMIC, FILTERS. Press the HOME  
(SETUP) button (11) to return to the home page.  
2
3
4
These show if a particular type of EQ is currently affecting  
the overall frequency response.  
Main graphic display  
This shows the frequency response of the selected type of  
EQ, or the overall response on the home page.  
Soft keys and  
secondary function  
display  
Select options and secondary functions as labelled on the  
right of main graphic display. Typically, these include Select  
to choose a particular filter, and Menu to step round a circular  
choice of options for that type of EQ. On the home page  
these buttons access the gain, delay and naming functions.  
5
6
Alphanumeric display  
and data entry knobs  
Displays menu pages for viewing/defining parameter values.  
Values are adjusted via the left, centre, right control knobs.  
BYPASS button  
On the home page this bypasses the complete unit for the  
selected channel (both channels if linked). When a  
particular EQ type is selected (by the buttons above the  
bypass switch), the bypass operates on that type of EQ only.  
Channel SELECT button  
7
8
Press to select either channel A or B for control. If the unit  
is linked for stereo operation then both indicators will be lit.  
Two part touch strip  
Press either part briefly to select a particular filter or fader.  
In Graphic EQ mode, press and hold to increase the level  
(upper strip) or reduce it (lower strip).  
9
PC port  
Use with the supplied cable to install software updates or to  
control the unit from an external computer.  
STORE and RECALL  
buttons  
10  
Used to store complete unit settings to one of the 64  
memory locations (32 from unit and 32 from the PC) and  
then to recall them.  
HOME (SETUP) button  
11  
Press once to return to the home page. Once on the home  
page, press and hold for one second to access the Setup  
menu. Step through the Setup menu (and exit after the last  
item) by repeatedly pressing this button.  
12  
13  
Metering  
Input,  
and Output metering incorporating  
multi-point clip indication.  
Power panel  
Power switch and power ON indication.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Reference  
1.2. DN9344E Front Panel  
1
2
1
5
7
8
1
2
1
5
3
4
6
9
3 4  
6
10  
1
2
3
Remote control active  
indicators (green) x 4  
These show that that the master unit is currently controlling  
the channel by remote control. Often referred to as the  
“me” light. There is one indicator for each of the channels  
1A, 1B, 2A and 2B.  
Alphanumeric displays  
for sections 1 and 2  
Each section has two large, red, three-digit alphanumeric  
displays that show electronic scribble-strip information, Last  
Memory Recalled and Communications Mode, or Set Up  
menu options.  
Display mode  
indicators (blue) for  
sections 1 and 2  
Each section has a blue indicator that illuminates to show  
that the large, red alphanumeric displays are showing Last  
Memory Recalled and Communications Mode. When  
extinguished, the displays are showing electronic  
scribble-strip names.  
4
5
Scribble Strips for  
sections 1 and 2  
Scribble-strip areas allow easy labelling of the unit. Use  
only chinagraph pencils to avoid permanently marking the  
unit. Remove chinagraph markings by wiping with a soft  
cloth. Do not use solvents as these may damage the  
surface.  
UP and DOWN buttons for  
sections 1 and 2  
Used to select various set up menu options including the  
communications channel for remote control and also contact  
closure mode. Active only when in the SETUP menu.  
6
7
Metering  
Input,  
and Output metering incorporating  
multi-point clip indication.  
SETUP button  
Press and hold for one second to access Set Up menu, then  
press to step through the Set Up pages.  
8
9
PC port  
Use with the supplied cable to install software updates or to  
control the unit from an external computer.  
Communictions traffic  
indicators  
These indicate when there is communications activity on any  
of the external interfaces. Transmit and receive data LEDs  
are shown for NETWORK (rear panel Ethernet data), DATA  
(front panel RS-232 PC port data) and RELAY (the rear panel  
RELAY contact closure input). In addition, IP ADDR and  
SUBNET LEDs illuminate when the IP Address or Subnet mask  
setup menus are selected.  
10  
Power panel  
Power switch and power ON indication.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DN9340E & DN9344E Key Features  
2. INTRODUCING THE DN9340E/DN9344E  
The Klark Teknik DN9340E Helix digital equaliser is a two-channel audio digital equaliser packaged in  
a 2RU, 19” rack-mounting format. The two channels can be controlled independently as two separate  
mono equalisers or linked for stereo operation. The unit has been designed to build on Klark Teknik's  
unrivalled reputation for high quality equalisation, while addressing a number of limitations in more  
conventional products.  
The Klark Teknik DN9344E Helix Slave digital equaliser is a 1U slave version of the DN9340E unit. By  
packaging FOUR channels of Helix processing into a 1U case, it offers unrivalled space efficiency, with  
a cost per channel lower than many less flexible products. The DN9344E can be controlled from a  
master DN9340E unit or by an external computer, and also has provision for contact closure  
operation.  
2.1. Host Software Versions  
This Operator Manual applies to Klark Teknik DN9340E and DN9344E Helix units that are running host  
software versions 4.01 and later. To check whether this manual covers the host software version that  
your unit is running, visit our website shown at the front of the manual.  
2.2. Key Features  
Key features of each unit are:  
Simultaneous availability of graphic and parametric equalisation  
In addition to the obvious advantages of a dual-purpose unit, this allows the engineer to separate out  
different sections of equalisation. For example, during setup and any sound check, the parametric  
mode can be used to set a basic EQ for the venue, with maximum flexibility. Once the show starts,  
however, the engineer can flip to graphic mode, which now starts off from a ‘flat’ baseline. Any  
problems that need fast attention during the show can now be addressed using the speed of  
operation of graphic EQ, and without confusion between the ‘showtime’ EQ and the original venue  
setup. At any time, a quick look at the home page will show the true overall response of the unit.  
Threshold Dependent Dynamic EQ (  
)
Over the years a number of dynamic EQ products have been introduced. These typically resemble a  
combination of a dynamics processor and an equaliser. This approach has the disadvantage that,  
while it is usually fairly easy to determine the level at which the dynamic EQ will start to operate, it is  
much harder to visualise the likely effect as the system is pushed harder or to set a maximum  
amount of EQ. The unique  
system developed by Klark Teknik with its dual thresholds  
provides unrivalled clarity of operation making this a very practical tool.  
Speed of operation  
Since the advent of digital signal processors, it has been possible to pack ever more functions into  
smaller boxes. However, if a function is buried in a hard-to-find sub-menu, which is only accessible  
after navigating a complex series of button presses, it may as well not be included. In live  
production, the operation of the unit is as crucial as the sound quality and this is a key part of the  
Helix design. The 2RU format permits a large graphic LCD display, while a second alphanumeric  
display provides clear value readouts above the control knobs without using up space on the main  
LCD. Dedicated selection buttons for the main functions, clear LED indicators, and no less than eight  
separate bargraph meters ensure that the unit is fast and accurate in operation. The unique  
two-section touchstrip provides instant access to filters and faders, so that Helix provides the same  
feeling of being “in control”, which is familiar to users of Klark Teknik analogue graphic equalisers.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DN9340E & DN9344E Key Features  
Space efficiency  
The Helix system allows exceptionally compact EQ systems to be assembled. For example, one  
DN9340E and six DN9344E units would provide 26 channels of EQ, each with graphic, parametric,  
and dynamic EQ, plus flexible filters, all in 8U of rack space.  
Interface to Midas consoles  
To further enhance the speed of operation of the Helix system, an interface is provided that connects  
to Midas Heritage and Legend series consoles. This allows the EQ system to be controlled  
automatically from the solo system of the console, ensuring that the correct EQ device is always  
ready for instant access.  
Remote control operation  
A slave network comprising DN9340E/DN9344E units linked together can be remotely controlled from  
a PC running the associated Elgar software application via the real panel Ethernet comms connectors  
(or RS-232 PC port on the front panel). This network can provide up to 32 channels, each with A and  
B inputs.  
Alternatively, a DN9340E master unit can control a network comprising up to 32 channels provided by  
DN9340E and/or DN9344E units acting as slaves. The master unit also acts as a single slave.  
Store and Recall Parameters  
The DN9340E includes two types of memory location, to provide maximum flexibility in a range of  
applications. There are 32 user memories in battery-backed-up SRAM and 32 preset memories in  
non-volatile FLASH memory. Recalling settings from either memory type uses the same procedure,  
and the user memories can be stored directly from the front panel of the unit. However, the FLASH  
memories can only be programmed directly from an external computer. This provides an absolute  
safeguard for valuable system settings, particularly in fixed installations.  
Klark Teknik has a policy of continuous development and may produce updates to the DN9340E or  
DN9344E host code. These can be downloaded to the unit via the front panel PC Port. To keep up  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9340E  
3. FRONT PANEL: DN9340E  
3.1. EQ Access and Displays  
1
2
3
4
Access buttons to control each type of equalisation: GRAPHIC,  
PARAMETRIC, DYNAMIC, and FILTERS. Pressing one of these  
buttons selects the type of EQ to be controlled. These  
buttons do not affect the actual sound at all - they just  
activate the controls. The large display will change to show  
the display for the selected EQ type, and the TYPE bypass  
LED will indicate whether this section is bypassed or not.  
The buttons illuminate to show which type of EQ is currently  
being controlled. Press the HOME (SETUP) button to return to  
the home page, which will show the overall system  
response.  
1
Access buttons  
2
EQ active LEDs  
These show if a particular type of EQ is currently affecting  
the overall response. Note that this is not just an indication  
of the bypass state. For example, if all the faders on the  
graphic EQ are flat, then the LED will not illuminate. If the  
graphic is not bypassed, and then a fader is moved away  
from zero, the LED will now illuminate to indicate that the  
response is now being affected by the graphic. This is  
particularly useful on the home page where it can be quickly  
seen what is contributing to the overall response.  
3
4
Main graphic display  
Soft keys display  
This shows the frequency response of the selected type of  
EQ, or the overall response on the home page.  
This area of the main graphic display labels the soft key  
functions. Typically these include Select to choose a  
particular filter, and Menu to step round a circular choice of  
options for that type of EQ. Additional functions include  
adding new filters (parametric and filter modes only) and  
selecting an individual fader or filter to be in or out. On the  
home page these buttons access the gain, delay, naming  
and A/B Link functions.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9340E  
3.2. Bypass, Channel Select, Soft Keys and Alphanumeric Display  
3
4
1
2
BYPASS button  
1
On the home page this bypasses the complete unit for the  
selected channel (both channels if linked). When a  
particular EQ type is selected (by the buttons above the  
BYPASS button), the bypass operates on that type of EQ only.  
Channel SELECT button  
Soft keys  
2
3
4
Press to select either channel A or B for control. If the unit  
is linked for stereo operation both indicators will be  
illuminated and the button will be inoperative.  
Soft keys for selecting options and secondary functions.  
These keys illuminate to indicate whether they are active in  
a particular mode.  
Alphanumeric display  
This shows parameter values for the current function being  
controlled by the encoder knobs. In general, when setting  
parameters, the labelling is directly above the relevant knob,  
with the title on the top row and the value on the bottom  
row.  
When selecting options or entering text, the top row shows  
the title on the left with the knob functions, separated by  
commas, on the right. The status is on the bottom row.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9340E  
3.3. Touch Strip, Store and Recall, Home (Setup) and Data Entry  
4
1
2
3
1
Two part touch strip  
The touchstrip is used to select individual faders or filters  
and can also be used to adjust gain settings. Press either  
part briefly to select a particular filter or fader. Press and  
hold or tap repeatedly to increase the level (upper strip) or  
reduce it (lower strip). Note that the lower strip is deeper  
than the upper one to reflect that it is generally more urgent  
to reduce gain. Pressing the upper and lower strips  
simultaneously allows the creation of fader groups.  
STORE and RECALL  
buttons  
2
3
Used to store complete unit settings to one of the 32 user  
memory locations and then to recall them. In addition to  
user memories, settings may be recalled from 32 preset  
memories that can only be manipulated by means of an  
external computer.  
HOME (SETUP) button  
Press once to return to the home page from any of the  
individual EQ pages. Once on the home page, press and  
hold for one second to access the setup menu. Step  
through the setup menu (and exit after the last item) by  
repeatedly pressing this button. The HOME (SETUP) button is  
also used to exit from STORE and RECALL operations.  
4
Left, centre and right  
encoder knobs  
Used for controlling values and selecting options. Each knob  
is surrounded by a blue ring that illuminates to show that  
the knob is active in the current mode.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9340E  
3.4. PC Port, Metering and Power  
6
1
2
3
4
5
1
2
PC port connector  
Input Metering  
8-pin mini-DIN socket for connecting to an RS-232 serial  
port on a PC or other remote control device. (Ethercon  
connectors are provided on the rear panel for remote control  
via Ethernet.)  
Input metering incorporating multi-point clip indication. This  
meter indicates the input level immediately after the input  
gain trim.  
3
4
Metering  
Dynamic EQ metering. Four meters are used for  
monitoring the four dynamic EQ filters.  
Output Metering  
Output metering incorporating multi-point clip indication.  
These meters indicate the actual level leaving the unit, while  
the red clip light indicates internal clipping (monitored  
throughout the internal processing stages) irrespective of  
actual output level.  
5
6
Power Switch  
Power on.  
Power ON indication  
Power indication.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9340E  
4. REAR PANEL: DN9340E  
1
2
3
7
5
4
6
5
4
1
2
3
4
Mains  
inlet socket  
Mains inlet unit is auto sensing over the range 100-240V AC.  
Ethernet  
2-port Ethernet switch for remote control using Cat-5  
cabling.  
RS-232 serial interface  
Inputs A and B  
RS-232 serial interface for Solo Tracking System operation  
in association with MIDAS consoles.  
Analogue – electronically balanced XLR audio input sockets  
Pinouts: Pin 1 Screen  
Pin 2 Hot  
Pin 3 Cold  
Digital – input A supports incoming 96kHz AES/EBU signals.  
Note that when digital input is selected, input B is inactive.  
AES/EBU is 110 Ohms. Sample rate converters (SRCs)  
support incoming signals at sampling frequencies from  
32kHz to 96kHz ± 12.5%, while allowing the unit to operate  
internally at 48kHz. An SRC bypass facility is available for  
48kHz operation, to eliminate the propagation delay through  
the SRC.  
Pinouts: Pin 1 Screen  
Pin 2 Data +  
Pin 3 Data -  
5
Analogue Outputs A  
and B  
Electronically balanced XLR audio output plugs  
Pinouts: Pin 1 Screen  
Pin 2 Hot  
Pin 3 Cold  
6
7
Digital Outputs A and B  
Word clock Input  
Digital AES/EBU output for channels A and B.  
AES/EBU is 110 Ohms.  
A word clock input is provided for synchronisation purposes.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Signal Flow: DN9340E  
5. SIGNAL FLOW: DN9340E  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6. OPERATION: DN9340E  
6.1. Home Page  
The home page is accessed from any of the EQ pages by pressing the HOME (SETUP) button. In the  
setup menu the HOME (SETUP) button is pressed repeatedly to move through the menus. After the last  
menu entry the display returns to the home page.  
On the home page, the large display shows the overall system response. Along the top edge, on the  
right, is the Memory number for the currently selected User or Preset Memory settings (storing and  
recalling settings are described later).  
The alphanumeric display shows the unit name and the name of the current working memory. On the  
home page, the bypass button will bypass all processing for the selected channel (A, B or both if  
linked for stereo in the setup menu).  
6.1.1  
Home page sub-menus  
This menu provides controls for the overall delay of the system and the input gain trim.  
The delay may be adjusted in coarse increments of 2.08ms (one sample at 48kHz sample rate) using  
the left encoder or in fine increments of 0.02 ms with the centre encoder. It is displayed in time units  
by default. Alternatively, the display can be selected to show distance in either Metric or Imperial  
units. Details of changing the units are found in the Setup menu section on page 32.  
The input gain control is adjusted by the right hand encoder between -40dB to +12dB in 0.1dB steps.  
Below -40dB the gain is set to “Off” and this mutes the input signal.  
Press HOME (SETUP) to return to home page.  
6.1.2  
A/B Link  
This menu allows the unit to be linked for stereo operation.  
Turn the right-hand encoder to select linked or non-linked (mono) mode. Note that when linking, the  
currently displayed channel will be copied to the other channel, so that both channels are then  
identical. In other words, if the “A” lamp (adjacent to SELECT button) is illuminated the settings for  
Channel A will be copied to Channel B. If the “B” lamp is illuminated, the settings for Channel B will  
be copied to Channel A.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.1.3  
Touchstrip Operation on the Home Page  
In the home page, the touchstrip is inoperative.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.2. Graphic Equalisation  
Select graphic equalisation by pressing the GRAPHIC button.  
The default display for the graphic EQ is 31 faders indicating the gain of the 31 bands of the 1/3  
octave equaliser. The left encoder can be used to select a fader and then the right encoder can be  
used to set the gain for that fader. Alternatively, the fader can be selected using the upper or lower  
section of the touch strip. If the touch strip is pressed for longer than half a second then the selected  
fader will move up (upper strip) or down (lower strip) until the touchstrip is released.  
6.2.1  
Soft Key Functions  
selects the next fader (to the right) or clears the current group selection  
(selector returns to the 20Hz fader).  
steps through the following pages on the alphanumeric display. After the  
last page, the next press returns to the first page, and so on.  
pressing this allows an individual fader or a selected block of faders to be  
switched in and out of circuit. Faders are shown as  
or if selected at the line.  
when switched out  
Default page shows frequency and level for the currently-selected fader  
EQ mode page  
EQ type - allows the selection of different EQ characteristics. Proportional, Constant and  
Symmetrical-Q types are available, together with emulations of the classic Klark Teknik  
DN360 and DN27. See the application notes later in this manual for more details on  
selecting EQ types and Q. If in doubt, select either DN27 or DN360 emulation for sensible  
curves with minimum fuss …  
Q - only available with Proportional, Constant and Symmetrical-Q types. This should be  
adjusted with care, as it is possible to produce both large amounts of overlap between  
bands and also narrow filters with large inter-band ripple. The default position for normal  
1/3 octave operation is clearly indicated on the display.  
Graph Mode - this toggles the large graphic display between the fader display and a  
frequency response curve.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
Automatic features page  
Auto Gain - this feature, originally introduced on the Klark Teknik DN3600 equaliser,  
automatically adjusts the system gain so that the overall program level remains constant  
despite changes in equalisation. The left encoder enables or disables this feature. If set to  
“No” then the graphic EQ gain trim (operated by the centre encoder) is entirely manual in  
operation. If set to “Yes”, then as the graphic EQ faders are moved, the gain trim will  
automatically be adjusted to compensate for the overall (average) level change. At any  
time, the display over the centre encoder will show the actual gain trim being applied, and  
this can always be adjusted manually (even when Auto EQ is active).  
Auto-EQ - Available only if the optional DN6000 interface is fitted, and a Klark Teknik  
DN6000 Real Time Analyser is connected to the DN9340E master. Use the 16-way ribbon  
cable (supplied) to interconnect the units, linking the DN9340E Expansion Slot 2 to the  
DN6000 Data Output connector.  
This function enables automatic room equalisation based on an audio spectrum from a DN6000.  
Note that the DN9340E auto equalises on the basis of a captured DN6000 ‘snapshot’; it does  
not auto-equalise in real-time. The Helix unit generates a reciprocal response curve that  
compensates for peaks and troughs in the snapshot audio spectrum, so creating a overall flat  
response.  
Auto Eq defaults to ‘No’. To select Auto Eq, turn the right encoder clockwise. An AutoEq soft  
key is added below ‘Menu’ and you are prompted to set the graphic EQ response to a 1/3  
octave symmetrical response (Q = 7.8), unless this is already set, as this is the only response  
that matches the filtering in the DN6000. Turn the centre encoder clockwise to confirm, or the  
left encoder clockwise to cancel Auto EQ. To capture the ‘snapshot’ audio spectrum, press the  
AutoEq soft key.  
In remote control applications, any slave unit can have the audio spectrum snapshots captured  
by the master unit. A slave DN9340E cannot capture snapshots from a DN6000 connected  
directly to it.  
EQ - Flat page  
This page allows the graphic EQ faders to be quickly reset to their unity gain position. To  
flatten the response, turn the centre encoder clockwise, then turn the right encoder clockwise  
to confirm. Pressing any other button will abort the sequence.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.2.2  
Touchstrip operation with Graphic equalisation  
On the Graphic EQ page, the touchstrip provides an alternative to using the encoder knobs for  
selecting and operating the faders on the display. If you are not currently using the Freq/Level  
menu, the unit automatically switches to it when you press the touchstrip. Touch either the upper or  
lower part of the touchstrip below the fader frequency that you want to select. The fader will  
highlight to indicate the selection. Tapping repeatedly at the same position will result in the fader  
level moving up (upper strip) or down (lower strip) in 0.5dB increments. Pressing the strip  
continuously in the same place will result in the fader ramping up or down over its full range. As an  
aid to resetting faders to exactly 0dB, this ramping motion will stop as the fader passes over the 0dB  
position. Release the touchstrip and then press again to continue moving past this point.  
6.2.3  
Grouping  
Groups of faders can be created and moved together. This is achieved by pressing below one fader  
on the upper strip, and below a different fader on the lower strip. A group will be created that  
includes all faders between those two selected ones. This can now be moved up and down using the  
encoder knob or by using the touchstrip in the area below the group. Pressing the touchstrip outside  
the range of the group or moving the “frequency” encoder knob will disband the group.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.3. Parametric Equalisation  
Select parametric equalisation by pressing the PARAMETRIC button.  
Soft key display  
The display for the parametric equaliser is similar to the home page, showing the frequency response  
- in this case just for the parametric sections. At the top is a legend that shows which PEQ section is  
currently active for control and also how many sections are in use. So, for example, if we have four  
sections in use and we are adjusting the second one, the legend would read “PEQ 2 of 4”. If no PEQ  
sections are active, then the display is blank except for the ADD key. Press this key to add a section  
of EQ.  
6.3.1  
Soft Key Functions  
selects which PEQ section is to be controlled.  
steps through the following pages on the alphanumeric display. After the  
last page, the next press returns to the first page, and so on.  
adds a new PEQ section. There are 12 PEQ sections available to each  
channel, each of which can be used across the whole frequency range from  
20Hz to 20kHz.  
pressing this allows an individual section to be switched in and out of circuit  
without clearing its settings.  
Default page displays frequency, Q and level for this section  
EQ settings page  
EQ type - this allows control over the characteristics of the equaliser. Proportional,  
Constant, and Symmetrical curves are available.  
Graph display - three modes are available, to ensure that clear information is available for  
any application. “Curve” mode shows the overall response of the whole parametric  
equaliser. “Active” mode shows just the response of the single section currently being  
selected for adjustment. “Individual” mode shows all the sections, but as individual curves  
rather than as a single composite response.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
EQ remove page  
This page allows the currently selected PEQ section to be deleted entirely (as opposed to  
bypassed see IN/OUT below). The centre encoder is turned clockwise to remove the section,  
and then the right encoder is also turned clockwise to confirm.  
6.3.2  
Touchstrip operation with Parametric equalisation  
On the Parametric EQ page, the touchstrip can be used to select the currently active section of EQ as  
an alternative to using the encoder knobs. If you are not currently using the Freq/Level menu, the  
unit automatically switches to it when you press the touchstrip. Press either the upper or lower part  
of the strip below the centre frequency of the required section. The centre frequency will highlight to  
indicate the selection. Once selected, the frequency of the EQ section can be dragged up and down  
the display by pressing the touchstrip and sliding the point of contact to left and right. There is no  
difference between the upper and lower strips when in Parametric mode.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.4.  
Dynamic Equalisation  
Select dynamic equalisation by pressing the DYNAMIC button.  
The display for the parametric equaliser is similar to the home page, showing the frequency response  
of the two  
dynamic EQ sections. However, please note that for each of the two sections  
there are two different curves drawn. These correspond to the response curve at high signal level  
and low signal level respectively. For more details on dynamic equalisation see the application notes  
later on page 55.  
6.4.1  
Soft Key Functions  
this switches the controls between the two dynamic EQ sections  
steps through the following pages on the alphanumeric display. After the  
last page, the next press returns to the first page, and so on.  
pressing this allows an individual section to be switched in and out of  
circuit.  
Default page displays frequency and Q/slope for this section  
Each of the sections can be used over the whole frequency range from 20Hz to 20kHz, and has fully  
parametric control over Q. In addition, each section can be selected to be a high or low shelf, with  
6dB/octave or 12dB/octave slopes. This is selected by turning the Q knob beyond its maximum value  
of 20.  
Lo Threshold / Level page  
This page contains the settings for the low threshold (the signal level that we want to call “quiet”) and  
the amount of cut or boost that we want at that “quiet” signal level.  
Hi Threshold / Level page  
This page contains the settings for the high threshold (the signal level that we want to call “loud”)  
and the amount of cut or boost that we want at that “loud” signal level.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
Time constants page  
This page allows the attack and release time constants to be set - in other words how quickly the unit  
will respond to a sudden increase in level (attack) or a sudden decrease in level (release).  
EQ settings page  
EQ type - this allows control over the characteristics of the equaliser. Proportional,  
Constant, and Symmetrical curves are available.  
Graph display - two modes are available, to ensure that clear information is available for  
any application. “Both” mode shows the overall response of the whole dynamic equaliser.  
“Active” mode shows just the response of the single section currently being selected for  
adjustment  
6.4.2  
Touchstrip operation with Dynamic equalisation  
On the Dynamic EQ page, the touchstrip can be used to select the currently active section of EQ. If  
you are not currently using the Freq/Level menu, the unit automatically switches to it when you press  
the touchstrip. Press either the upper or lower part of the strip below the centre frequency of the  
required section. The centre frequency will highlight to indicate the selection. Once selected, the  
frequency of the EQ section can be dragged up and down the display by pressing the strip and sliding  
the point of contact to left and right. There is no difference between the upper and lower strips when  
in Dynamic mode.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.5. Filters  
Select filters by pressing the FILTERS button.  
Number of active filter section  
Soft key display  
The display for the filters is similar to the home page, showing the frequency response - in this case  
just for the filters. At the top is a legend that indicates which filter is currently active for control and  
also how many filters are in use. So, for example, if we have three filters in use, and are adjusting  
the second one the legend would read “Filter 2 of 3”. If no filters are active, then the display is blank  
except for the ADD key. Press this key to add a filter.  
6.5.1  
“Create Filter” function  
Turn the left encoder to select the type of filter required. The available options are Notch, Low-pass  
(normal and peaking), High-pass (normal and peaking), Hi shelf and Lo shelf. Turn the right encoder  
to confirm the selection and create the filter. There are four filters available to each channel, each of  
which can be used across the whole frequency range from 20Hz to 20kHz.  
6.5.2  
Soft Key Functions  
selects which filter is to be controlled.  
steps through the following pages on the alphanumeric display. After the  
last page, the next press returns to the first page, and so on.  
adds a new filter.  
pressing this allows an individual section to be switched in and out of  
circuit.  
Default page displays the main parameter controls for each filter  
The controls available vary depending on the type of filter selected:  
Filter Type  
Left Encoder  
Frequency  
Centre Encoder  
Right Encoder  
Notch  
Q
-
Low Pass (LPF)  
High Pass (HPF)  
Hi Shelf  
Frequency  
Frequency  
Frequency  
Frequency  
Normal/Peaking  
Normal/Peaking  
Slope  
Slope/Gain  
Slope/Gain  
Level  
Lo Shelf  
Slope  
Level  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
Filter settings page  
Filter type - available types are Notch, Low Pass (normal and peaking), High Pass (normal  
and peaking), Hi Shelf and Lo shelf.  
Graph display - three modes are available, to ensure that clear information is available for  
any application. “Curve” mode shows the overall response of the whole filter module.  
“Active” mode shows just the response of the single filter currently being selected for  
adjustment. “Individual” mode shows all the filters, but as individual curves rather than as  
a single composite response.  
Filter remove page  
This page allows the currently selected filter to be deleted entirely (as opposed to bypassed - see  
IN/OUT below). The centre encoder is turned clockwise to remove the filter, and then the right  
encoder is also turned clockwise to confirm.  
Turn the left encoder to select the type of filter required. The available options are Notch, Low-pass  
(normal and peaking), High-pass (normal and peaking), Hi shelf and Lo shelf. Turn the right encoder  
to confirm the selection and create the filter. There are four filters available to each channel, each of  
which can be used across the whole frequency range from 20Hz to 20kHz.  
6.5.3  
Touchstrip operation with Filters  
On the Filters page, the touchstrip can be used to select the currently active filter. If you are not  
currently using the Freq/Level menu, the unit automatically switches to it when you press the  
touchstrip. Press either the upper or lower part of the strip below the centre frequency of the  
required filter. The centre frequency will highlight to indicate the selection. Once selected, the  
frequency of the filter can be dragged up and down the display by pressing the strip and sliding the  
point of contact to left and right. There is no difference between the upper and lower strips when in  
Filter mode.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.6. Metering  
Comprehensive audio metering is provided by eight LED bargraph meters:  
There are a pair of input meters (labelled “A” and “B” for audio channels A and B,  
respectively) that show the input level immediately following the input gain  
control. These can therefore be used as a guide for setting the input gain to  
match the signal level being sent to the unit. With the input gain control set to  
0dB (unity gain) then full-scale on the meter will occur at a signal level of +21dBu,  
which is the maximum permissible signal level. The input meters incorporate a  
red ‘clip’ LED that indicates signal clipping both on the actual input to the unit and  
also after the gain control. This ensures that all possible clip conditions are  
monitored irrespective of the setting of the gain control.  
There are a pair of output meters (labelled “A” and “B” for audio channels A and  
B, respectively) that show the output level from the unit. Full-scale on the meter  
indicates maximum output from the unit, which corresponds to +21dBu. The  
output meters also incorporate a red ‘clip’ LED. This indicates signal clipping  
within the unit, and is monitored at all internal points where gain can be applied.  
Thus, if a large amount of gain is added with one section of a parametric EQ,  
resulting in a clipped signal, but the level is then reduced by a subsequent EQ  
section, the clip LED will still illuminate to indicate the internal clip condition  
despite the apparently safe output level. In this situation the input gain should be  
reduced to provide sufficient headroom for the desired EQ characteristic. Note  
that because these meters are on the output of the unit, they will show the effect  
of any delay that has been selected.  
There are four meters which show the action of the  
dual-threshold  
dynamic EQ system, one meter for each EQ section on each of the two audio  
channels A and B. The dynamic EQ meters are calibrated in percentage terms,  
from 0 to 100. If no dynamic EQ is selected or if the signal is below the ‘low’  
threshold, then the meters will show 0% (that is, no LEDs illuminated). Under this  
condition the dynamic EQ will be using the ‘low’ frequency response settings. If  
the signal level is above the ‘high’ threshold, the relevant meter will indicate 100%  
(fully illuminated) showing that the ‘high’ EQ settings are now being applied. If  
the signal is between the two thresholds, then the EQ will be morphing between  
the two EQ settings, and the meter indicates the signal level relative to the two  
thresholds. Note that the effect of the attack and release controls is also indicated  
on these meters - the height of the bar indicates the actual EQ being applied, so if  
a slow release is set, for example, you will see the meter drop back slowly  
following a peak.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9340E  
6.7. Clear Down Sequence  
Because of the comprehensive facilities available on the DN9340E, it may be important to ensure that  
the unit is ‘cleared down’ before use. Remember to clear down both channels A and B if the unit is  
not linked for stereo operation. There are a number of possible strategies for this:  
A. Recall a memory that contains a suitable set of default values  
See Section 8 for further details on storing and recalling memories.  
B. Select each type of EQ, and bypass them in turn as follows:  
1
2
3
Press GRAPHIC, then BYPASS (the TYPE bypass LED illuminates), PARAMETRIC, then BYPASS, and  
so on for DYNAMIC and FILTERS.  
Finally, press HOME (SETUP), press the soft key labelled Delay/Gain and set the delay and gain to  
zero values.  
Press HOME (SETUP) again, and the unit is ready to use and set to provide a flat response.  
This method is fast, but has the disadvantage that when the BYPASS function is deselected for a given  
type of EQ, the previous settings will be restored, which may not be what is required.  
C. To ensure that each type of EQ is zeroed-out and can be introduced seamlessly into  
circuit, follow this sequence:  
1
2
Press HOME (SETUP), then select the soft key labelled Delay/Gain. Set delay and gain to zero.  
Press GRAPHIC. Press the soft key labelled Menu three times to display the EQ FLAT menu page.  
Turn the centre encoder clockwise, then the right encoder clockwise to confirm.  
3
Press PARAMETRIC. If parametric EQ sections exist, then press the soft key labelled Menu twice  
to display the Remove menu page. Turn the centre encoder clockwise, then the right encoder  
clockwise to confirm deletion of the selected parametric section. Repeat these encoder  
moves until no sections of EQ remain.  
4
5
Press DYNAMIC. Press the soft key labelled Menu five times to display the EQ FLAT menu page.  
Turn the centre encoder clockwise, then the right encoder clockwise to confirm.  
Press FILTERS. If filter sections exist, then press the soft key labelled Menu twice to display the  
Remove menu page. Turn the centre encoder clockwise, then the right encoder clockwise to  
confirm deletion of the selected filter section. Repeat these encoder moves until no filters  
remain.  
6
Press HOME (SETUP) to return to the home page.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7. SETUP MENU: DN9340E  
7.1. General  
The DN9340E provides various set up options for adapting the operation of the unit to best suit your  
operational requirements and preferences, as follows:  
Comms channel setting for controlling a network remotely  
via a PC or using a DN9340E as a master controller (Page 1)  
Front panel lockout for security (Page 2)  
Analogue/digital input select (Page 3)  
Digital output clock select (Page 4)  
Password Page for preset protection (Page 5)  
LCD Display settings (Page 6)  
Unit naming (Page 7)  
Memory naming (Page 8)  
Delay units of measurement (Page 9)  
Power-up logo (Page 10)  
Ethernet settings for remote control operation (Pages 11  
and 12)  
These options are programmed in the Set Up menu and are described in the following sections in  
menu order.  
To access the Set Up menu pages  
Press HOME (SET UP) to return to the Home page.  
Press and hold the HOME (SET UP) button to open the menu.  
Press the HOME (SET UP) button repeatedly to step through the pages in turn.  
Note  
This menu does not ‘cycle’. On completing the set up, the menu returns  
to the Home page.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.2. Comms channel (Page 1)  
The Comms page lets you select the communications channel on which the unit, acting as slave, will  
send/receive data to/from a controlling PC. Alternatively, you can select the DN9340E unit as a  
master to control the network. The master unit not only controls the network but also acts as a slave  
unit.  
7.2.1  
Remote control via a PC  
Comms channels 1 to 32 are available that provide up to 64 inputs in a slave network comprising  
DN9340E and/or DN9344E units. The units are remotely controlled from a PC using the Elgar Library  
Manager and HELIX DN9340E/DN9344E RCS add-in software. For more information on remote  
control set ups, see Section 10.  
Note  
When using Ethernet communication, you will need to set up the unit’s  
IP address and Subnet mask before selecting the comms channel, see  
Section 7.11 for further details.  
To select a slave remote communications channel  
1
2
3
Press HOME (SETUP) for more than one second to access the  
Set Up menu; you will be taken immediately to the Comms  
page.  
Use the left control knob to go to the communications  
channel on which you wish to control the unit remotely, for  
example, scroll through to channel 14.  
Press HOME (SETUP) to confirm the selection.  
The front panel controls, except the HOME (SETUP) button, are locked out to facilitate remote operation.  
The display indicates that the unit is under remote control. See Section 10 for further details.  
To switch remote communications off  
1
2
3
Press and hold the HOME (SET UP) button to re-open the  
Comms page.  
Turn the left control knob anti-clockwise to select “Channel”  
as “Off”.  
Press HOME (SETUP) to confirm the selection.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.2.2  
Using a DN9340E for master control  
Comms channels 1 to 32 are available, enabling a mater/slave network with one DN9340E unit acting  
as the master and up to 31 DN9340E and/or DN9344E slave units.  
To select a master remote communications channel  
1
Press HOME (SETUP) for more than one second to access the  
Set Up menu; you will be taken immediately to the Comms  
page.  
2
3
4
5
Turn the left control knob clockwise to access the  
communications channels (SLAVE Mode).  
Turn the centre control knob clockwise to display  
communications channels in MASTER Mode.  
Turn the left control knob to select required master channel,  
for example, channel 23.  
Turn the right control knob to select the maximum number  
of inputs in the network, for example, 16. Inputs are always  
in pairs (two inputs per channel) and you can have a  
maximum of 64.  
6
7
Press HOME (SETUP). You have the option to upload the  
memory from the networked units (“Get All”) or download  
the memory from this unit to the other networked units  
(“Set All”). To access the “Set All” option, turn centre  
control knob anti-clockwise.  
Press HOME (SETUP). The unit will search for the other  
networked units and then display the following:  
The front panel controls, except the HOME (SETUP) button, are locked out to facilitate remote operation.  
The display indicates that the unit is the master and is controlling the network.  
To select a slave communications channel  
To set the unit as a slave and select the communications channel, follow the procedure in “To select a  
slave remote communications channel” on page 27.  
To remove the unit from the network  
1
2
3
4
Press and hold the HOME (SET UP) button to reopen the Comms page.  
Turn the centre control knob anti-clockwise to select Mode as “SLAVE”.  
Turn the left control knob anti-clockwise until Channel is set to “Off”.  
Press HOME (SETUP) to confirm your selection.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.3. Front Panel lock (Page 2)  
This allows the front panel controls to be locked by means of an eight-character password. Four  
levels of Panel Lock are possible:  
Unlocked – All controls available.  
Lock + Recall – This leaves the Recall button active so that  
saved memories can be still be recalled.  
Locked – Imposes a full lockout on the front panel controls,  
except the HOME (SETUP) button.  
Function Lock – Allows you to lock the six functions, that  
is, graphic EQ, parametric EQ, dynamic EQ, filters, delay  
gain and link, in any combination.  
In all cases, limited Set Up menu options remain available, namely the Comms Channel, Panel Unlock  
pages and Power Up pages. To unlock a unit, press HOME (SETUP) once, then press and hold HOME  
(SETUP) to enter the Setup menu.  
To set a Panel Lock  
1
2
Step through the Set Up menu to the Panel Lock menu page.  
Use the left and centre control knobs to set a password of eight characters, including blank  
spaces, made up of letters, numbers and/or symbols.  
Important! Preliminary and subsequent blank spaces are recorded as part of the  
eight-character password. Therefore, if you use a short password, the characters must be  
re-entered in exactly the same position to unlock the panel. To avoid confusion, either record  
the blanks as part of the password or enter the word at the far left of the display.  
3
4
Turn the right control knob clockwise to cycle to the required lock type.  
Press HOME (SETUP) to apply the Panel Lock.  
The Home page now indicates that the unit is ‘Locked’. The lock state is retained after power down,  
and will be indicated on the Home page when the unit is powered up again.  
To remove the Panel Lock  
1
2
Step through the Set Up menu to the Panel Lock page.  
Use the left and centre control knobs to enter the password. Note that the letters must be in  
the same position as when the password was set.  
3
4
Turn the right control knob clockwise to apply the password.  
If correct, the display will report ‘UNLOCKED’. Press HOME (SETUP) to exit the page and return  
to normal operation.  
If you have entered the wrong password, the DN9340E will flag it as incorrect and return to  
the Panel Unlock page for a further attempt.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.4. Analogue/Digital Input Select (Page 3)  
This page selects the input source for input channels A and B on a paired basis due to the sharing of  
channels for the AES/EBU input. There are six options available:  
‘Anlg INT’ –audio source is analogue inputs. Internal digital  
clock is synchronised to on-board reference (either 44.1 kHz  
or 48 kHz).  
‘Anlg WCK’ - audio source is analogue inputs. Internal  
digital clock is synchronised to external word clock input  
(either 44.1 kHz or 48 kHz).  
‘Dig INT’ - audio source is digital input via sample rate  
converter (input source sampling frequency up to 96 kHz).  
Internal clock is synchronised to on-board reference (either  
44.1 kHz or 48 kHz).  
‘Dig WCK’ - audio source is digital input via sample rate  
converter (input source sampling frequency up to 96 kHz).  
Internal digital clock is synchronised to external word clock  
input (either 44.1 kHz or 48 kHz).  
‘DLck AB’ - audio source is digital input bypassing sample  
rate converter (input source either 44.1 kHz or 48 kHz) to  
eliminate converter latency. Input digital clock is  
synchronised to clock derived from digital audio input.  
Note: clock reference setting must match frequency of  
digital audio input.  
‘DLck WCK’ - audio source is digital input bypassing sample  
rate converter (input source either 44.1 kHz or 48 kHz) to  
eliminate converter latency. Internal digital clock is  
synchronised to external word clock input (either 44.1 kHz  
or 48 kHz). Note: digital audio input and word clock  
reference must be the same sampling frequency.  
To change the input source  
1
2
Step through the Set Up menu to the Input Source select page.  
Use the left control knob to select the input source for channels A and B.  
Note  
The ‘Ref’ menu shows the clock reference for the DN9340E, for example, Internal.  
If the input is set to ‘DigLock’, then this menu becomes active; turn the right control  
knob to select the input clock reference from internal to AB (lock to the channel’s  
incoming AES/EBU bit stream).  
For each of the six input sources the “Ref” and “WLCK” menus each have two options, 48kHz and  
44.1kHz.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.5. Digital Output Clock Select (Page 4)  
This page selects the clock reference for the digital AES/EBU outputs. Note that the output clock  
reference settings are independent of sampling frequency. The available options are:  
‘System’ – the digital output is locked to the DN9340E’s  
system clock. Note that this is the default setting.  
‘DigSRC  
WCLK’ – the digital output is locked to the word  
clock reference input located on the rear panel of the unit.  
‘DigIn AB’ – the digital output is locked to the digital input  
channel’s incoming AES/EBU bit stream. Note that this  
option may only be selected when the input select is set to  
‘DLck AB’, see Section 7.4.  
To select the output clock source  
1
2
Step through the Set Up menu to the Output Clock select page.  
Use the right control knob to select the clock source.  
Note  
To select ‘DigIn AB’, the unit’s input select must be set to be digital and  
running in ‘DLck AB’ mode, see Section 7.4.  
7.6. Presets lock (Page 5)  
This allows the presets to be password protected to prevent unauthorised editing. The password is  
six characters long.  
To set a Presets lock  
1
2
Step through the Set Up menu to the Presets lock menu  
page.  
Use the left and centre control knobs to set a password of six characters, including blank  
spaces, made up of letters, numbers and/or symbols.  
Important! Preliminary and subsequent blank spaces are recorded as part of the  
six-character password. Therefore, if you use a short password, the characters must be  
re-entered in exactly the same position to unlock the presets. To avoid confusion, either  
record the blanks as part of the password or enter the word at the far left of the display.  
3
4
Turn the right control knob clockwise to cycle to the Lock  
page.  
Press HOME (SETUP) to apply the Presets lock.  
The lock state is retained after power down.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.7. LCD contrast adjustment (Page 6)  
To ensure optimum screen visibility in a range of lighting conditions, it is possible to individually  
adjust the contrast of the two LCD displays.  
“Alpha” adjusts the contrast of the alphanumeric display  
“Graphic” adjusts the contrast of the large graphic display  
“INV” allows the mode of the graphic LCD to be switched between white-on-blue to blue-on-  
white.  
7.8. Naming (Pages 7 and 8)  
To help with system identification, the DN9340E unit and the current working memory may each be  
given a name up to 20 characters long.  
Both names are shown in the Home page and are retained after power down, which is particularly  
useful for system reassembly when changing venues.  
To enter a name  
1
Use the left control knob to move the cursor right or left, and the centre control knob to  
select the letter, number or symbol. (Tip: to clear existing characters enter a blank space  
which can be found after the letter Z.)  
2
Press HOME (SETUP) to apply the new name.  
All names are stored with System memory settings. The Store function will assume the working  
memory name as the default memory name, prompting you to edit it if required (see Section 8  
Storing and Recalling Settings).  
7.9. Delay options (Page 9)  
The units of measurement used to specify the delay settings can be set to suit user preference, as  
follows:  
Time (milliseconds and microseconds)  
Metric distance (metres)  
Imperial distance (feet and inches)  
To change the units of measurement  
1
2
Turn the left control knob to choose the units.  
For Metric or Imperial distance measurement, specify the ambient temperature of the venue  
using the centre control knob. The DN9340E will use this to adjust the speed of sound (which  
varies with temperature) in the delay calculation so that accurate delays are applied to the  
channels.  
The delay units are changed in the input and output menus, with the current values being  
automatically converted to equivalent values.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.10.Power-up Logo (Page 10)  
The equaliser normally shows a logo page during power-up, including information such as software  
version number.  
To switch the logo on/off, turn the left control knob.  
7.11.Ethernet Settings (Pages 11 and 12)  
When controlling the DN9340E unit remotely via Ethernet, the unit requires an individual IP Address  
and Subnet Mask to be set. For more information on DN9340E remote control set ups, see Section 8.  
7.11.1  
Ethernet IP Address (Page 11)  
The IP Address is entered manually on each unit in the network using the DN9340E’s front panel  
controls.  
To check the current IP Address  
1
With the DN9340E connected to your  
network, step through the Set Up menus  
to the Ethernet IP Network setup page  
shown opposite.  
2
Turn the left control knob and the unit  
will scan the network to obtain the IP  
address.  
At the end of the scan, which takes a few seconds, the display updates with an IP address as shown  
above. The Default IP Address is 192.168.1.1.  
To set the IP Address  
1
2
3
Turn the left control knob to highlight the area of the IP Address you wish to change.  
Now turn the centre control knob to select a number from 0 to 255.  
Press HOME (SETUP) to confirm the new IP Address.  
It is important that all units and the controlling PC have a unique IP  
Address in order for the network to function correctly. For more  
information on configuring your network, please see the HELIX DN9340E  
and DN9344E RCS User Guide.  
Note  
After setting the IP address you need to check the Ethernet IP Address Subnet mask on each unit,  
see Section 7.11.2.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menu: DN9340E  
7.11.2  
Ethernet Subnet Mask Setup (Page 12)  
After setting the IP Address, it is necessary to check the Ethernet IP Address Subnet mask on each  
unit. The default subnet mask is 255.255.0.0.  
To check and edit the Subnet Mask  
1
2
3
Step through the Set Up menus to the  
Ethernet S/Net Network setup page  
shown opposite.  
Turn the left control knob and the unit  
will scan the Network to obtain the  
Subnet Mask.  
Turn the left control knob to highlight  
the area of the Subnet Mask you wish  
to change.  
4
5
Now turn the centre control knob to  
select a number from 0 to 255.  
Press the HOME (SETUP) to confirm the  
new Subnet Mask.  
It is important that all units and controlling PCs have the same Subnet  
Mask to function correctly. You may want to modify Subnet Masks  
where one area of the network is required to be ‘hidden’ from another,  
for example, in an installation with one network but multiple  
auditoriums. For more information on configuring your network, please  
see the HELIX DN9340E and DN9344E RCS User Guide.  
Note  
For more information on remote control setups, see Section 9.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the DN9340E Memories  
8. STORING AND RECALLING SETTINGS: DN9340E  
The DN9340E includes two types of memory location, to provide maximum flexibility in a range of  
applications. There are 32 user memories in battery-backed-up SRAM and 32 preset memories in  
non-volatile FLASH memory. Recalling settings from either memory type uses the same procedure,  
and the user memories can be stored directly from the front panel of the unit. However, the FLASH  
memories can only be programmed directly from an external computer. This provides an absolute  
safeguard for valuable system settings, particularly in fixed installations.  
To store settings:  
1
Press STORE.  
2
Turn left encoder knob to select the destination (U01 to  
U32), for example, “U02”.  
3
4
Press STORE again to confirm (or HOME (SETUP) to abort). The  
far left character of the store name flashes.  
Use the centre encoder knob to select characters, and the  
left one to move left and right, to enter a suitable name for  
the memory. Alternatively, if the name already there  
indicates that you do not want to overwrite it, then HOME  
(SETUP) will abort the store operation as before.  
5
Press STORE again to confirm. This will return you to the home page.  
To recall settings:  
1
Press RECALL.  
2
Turn the left encoder to select the user (SRAM) memory  
required, or the centre encoder to select a preset (FLASH)  
memory, for example, “U02”.  
3
Press RECALL again to confirm. The display will show the  
following and then return you to the home page.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
9. DN9340E AND DN9344E MASTER/SLAVE REMOTE CONTROL  
A DN9340E master unit can control multiple DN9340E and DN9344E units as slaves.  
For more details on linking units together and remotely control from a  
PC, see Section 10.  
Note  
9.1. Connections  
In order to set up a master/slave network Helix system, first connect the units together using the  
Ethercon connectors on the rear panel, as shown in Section 10.2.  
9.2. Addresses  
The network uses a system of addresses to identify which unit is being controlled. The Helix system  
supports addresses from 1 to 32. A DN9340E unit has one address and a DN9344E has two  
addresses, corresponding to the left-hand pair of channels (Section 1) and the right-hand pair of  
channels (Section 2), respectively. The reason for having two addresses to communicate with each  
DN9344E is to allow systems to be built up from either DN9340E (two audio channels) or DN9344E  
(four audio channels) in any combination. At any time, two DN9340Es can be replaced by a single  
DN9344E (or vice versa) without any need to change the addressing of the system.  
9.3. Data model  
Each Helix unit has a working memory which is the current state of the unit as seen on the front  
panel - this also corresponds to the sound that is currently being heard. In addition, there are 32  
user and 32 preset memories in each DN9340E and in each pair of channels in a DN9344E.  
Issuing a store command to a unit will copy the working memory into the selected user  
memory on that unit.  
Issuing a recall command will copy the selected user or preset memory into the  
working memory on that unit.  
When using remote control, the Master unit holds a local copy of the working memory for each slave  
that is connected. This allows fast switching between units being controlled. When the system is set  
on-line, the user can choose whether to “Get all” data from the slaves or to “Set all” data from the  
master. This allows the settings for up to 64 channels of audio to be stored in a single DN9340E or,  
conversely, an “empty” master DN9340E can be connected to a system that is already running and  
upload the system data.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
9.4. Getting started  
Connect the units using the Ethernet ports as described above. Set the comms address for each  
slave unit - ignore the master unit for now. It doesn't matter what addresses you use, but each unit  
MUST have a unique address (two unique addresses for a DN9344E).  
On a DN9340E:  
1
2
3
Press and hold HOME (SETUP). The left encoder illuminates, to show that it is active.  
Turn left encoder to select the SLAVE channel number.  
Press HOME (SETUP) to confirm.  
On a DN9344E:  
1
2
3
4
5
6
Press SETUP.  
Press and hold SETUP.  
Use the UP and DOWN buttons to select the channel number for Section 1.  
Repeat for Section 2.  
Press SETUP to confirm (unit will display password menu).  
Exit by pressing SETUP to step through the menu.  
Setting the master unit on-line:  
Once all the slaves have been set up, the master unit can be set on-line. Again, it must have a  
communication channel allocated, which must not be the same as any of the slaves.  
1
2
Press and hold HOME (SETUP). The left encoder illuminates, to show that it is active.  
Turn left encoder to select the channel number for the master unit. Turn the centre encoder  
to select MASTER mode. Turn the right encoder to select the maximum number of audio  
channels in the system.  
3
Press HOME (SETUP) to confirm.  
The reason for setting the maximum number of audio channels is to prevent the master unit from  
wasting time looking for units that are not present and trying to set them on-line, while allowing the  
user to choose any channel addresses that are convenient. For example, a system including two  
DN9340Es and two DN9344Es will have 12 audio channels, so set the “Max” value to 12. When the  
master unit goes on-line it will search for units starting from address 1. Once it finds the correct  
number of audio channels, it will stop searching.  
4
5
The unit will now ask you to choose either to “Set All” slaves to the data contained in the  
master unit (from the master unit's local copy of the slave data for each address) or to “Get  
All” data from the slaves themselves. Use the centre encoder to select which one you want.  
Press HOME (SETUP) to confirm. The unit will show a “DETECTING UNITS” page as it searches  
and initialises the slaves. The system is now on-line.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
9.5. Operation  
To select slaves, go to the home page by pressing HOME (SETUP).  
1
Press the lowest of the four soft keys labelled "Comms”. A set of boxes will appear on the  
large graphic screen. The boxes will contain channel numbers, which correspond to each  
audio channel in the system.  
2
Use the touchstrip to select the channel that is to be controlled. Units above the line are  
selected using the upper touchstrip and units below the line using the lower touchstrip.  
The A/B SELECT button can also be used to move between slave channels in the same way as  
for normal DN9340E operation.  
Note  
Pressing and holding the A/B SELECT button provides a fast shortcut to the Comms page from  
any of the EQ pages (graphic, parametric etc). If this method is used to access the Comms  
page, then the master unit will remember which EQ page was in use when that slave is next  
selected for use.  
9.6. System naming  
To ensure clarity of operation, each slave can be assigned a meaningful name in addition to its  
channel name (1A, 3B etc.).  
To set up the names  
1
2
First select the Comms page on the master unit.  
Now press the second soft key (labelled “System”). This opens the system configuration  
page.  
A highlighted area shows the field that is currently being edited.  
The left encoder scrolls up and down the list of units.  
The touchstrip is used to select the column to be edited.  
3
4
The following name fields can be edited:  
Long name: This 20-character name will be used on the master unit to indicate to the  
user which of the slaves is being controlled. It is also displayed on any DN9340E units  
that are being used as slaves. The first nine characters are not editable, and show the  
channel number. The last eleven characters are editable by the user.  
Name: This three-character name will be used on the front-panel displays of any  
DN9344E units in the system.  
Once all the assignments have been made, press Confirm to return to the Comms page.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
9.7. Copy channel function  
It is possible to copy a whole audio channel's settings to another channel or to multiple channels.  
Mono channels can only be copied to other mono channels, and stereo linked channels can  
only be copied to other stereo linked channels.  
Note  
1
2
On the Master unit's Comms page, press the soft key labelled Copy Mon (to copy mono  
channels) or the soft key labelled Copy St (to copy stereo channels).  
Use the touchstrip to select the channel that you wish to copy from. Note that only channels  
of the selected type (mono or stereo) are shown.  
3
4
Press the soft key labelled Confirm to select the source channel.  
Now, the possible destination channels are shown. Use the touchstrip to select one or more  
channels to copy to. Once all the destination channels are selected, press the soft key labelled  
Confirm. The unit will display an “are you sure” message, and a final press of the Confirm soft  
key will start the copying process.  
At any time, the copy can be aborted by pressing the HOME button.  
9.8. Solo Tracking operation  
Instead of selecting slaves manually from the master unit, the Helix system can be controlled from  
the solo system of Midas Heritage and Legend consoles. The console RS-232 port is connected to the  
RS-232 connector (D9) on the rear of the master DN9340E unit using a straight-wired cable (no  
crossovers). Once the channel assignments have been configured (see below), pressing a solo button  
on the console will automatically select the channel of EQ that corresponds to that console function  
onto the master unit, ready to be controlled.  
To set up the assignment  
1
2
First select the Comms page on the master unit.  
Now press the second soft key (labelled “System”). This opens the system configuration  
page.  
-A highlighted area shows the field that is currently being edited.  
-The left encoder scrolls up and down the list of units.  
-The touchstrip is used to select the column to be edited.  
3
The following fields can be edited:  
Solo Tracking: This allows each audio channel to be associated with a type of solo  
function on the Midas Heritage or Legend console. The available functions are: None,  
Input, Group, Aux, Matrix, Solo Clear.  
Chan: This selects the particular channel solo that will be used for that channel of EQ.  
So, for example, if slave EQ channel 1A is configured with Autosolo, set to Group and Chan to 5.  
Then pressing group solo 5 on the console will select slave EQ channel 1A onto the master Helix unit  
for control.  
4
Once all the assignments have been made, press Confirm to return to the Comms page.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
10. DN9340E AND DN9344E REMOTE CONTROL SETUP  
A slave network of up to 32 DN9340E/DN9344E units can be linked together and remotely controlled  
from a PC running the Elgar Library Manager and HELIX DN9340E or DN9344E RCS add-in software.  
Further details on these commercially available software applications can be found on the Klark  
10.1.Overview  
To control an equaliser network, the laptop/PC running HELIX RCS is connected to the network in  
place of a Master DN9340E HELIX, assuming control of the daisy-chained HELIX units under pre-set  
slave addresses. The following options for connecting the laptop/PC to the HELIX unit(s) are  
available:  
Ethernet:  
Covers direct Ethernet, Local Area Network (LAN) or wireless connection,  
converting to an RS-232 front panel input via a Lantronix UDS 100 Converter.  
Wireless offers increased flexibility during the event set-up, as the engineer can  
move around freely with a laptop and adjust the equalisation while listening to the  
end effect at any place in the venue.  
Serial (option): The optional RS-232 serial connection is via the “PC PORT” on the front panel of  
the first HELIX unit. It is possible to connect other HELIX DN9340E/DN9344E units  
via the rear Ethernet port(s) when using a serial connection, but note that this will  
be slower that using Ethernet.  
The following sections describe how to connect the master HELIX RCS laptop/PC to the system for  
each option, and the interconnectivity of the HELIX DN9340E/DN9344E units.  
Note If Solo Tracking input is required, the first slave HELIX must be a DN9340 and the front panel  
RS-232 PC Port must be used, see Page 44.  
10.2.HELIX DN9340E/DN9344E unit interconnections  
The HELIX DN9340E/DN9344E units in your system can be connected together in a daisy chain, or  
each one can be connected to an Ethernet switch or hub.  
Note When connecting the Ethernet cable to the rear panel of a HELIX DN9340E or DN9344E unit,  
either of the Ethernet sockets can be used.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
10.2.1 Connecting the HELIX DN9340/DN9344E units in a daisy chain  
The diagram below shows a typical example of the HELIX DN9340/DN9344E units connected in a  
daisy chain configuration.  
10.2.2  
Connecting the HELIX DN9340E/DN9344E units to an Ethernet  
switch or hub  
The diagram below shows each HELIX DN9340E/DN9344E unit directly connected to an Ethernet  
switch or hub, which is then connected top a laptop/PC.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
10.3.Ethernet Connection  
For familiarisation purposes, a basic Ethernet connection may be made to a single unit by connecting  
the Ethernet cable to either of the unit’s rear panel Ethernet sockets and to the network socket on the  
laptop PC or wireless access point (wireless option).  
Note For Ethernet connectivity, the HELIX DN9340E/DN9344E units must be operating V4.00 (or  
later) host code.  
10.3.1 Ethernet connection – standard  
Alternatively, you can set up a system involving multiple units. One end of the Ethernet cable is  
connected to the network socket of the laptop/PC. The other end is either connected to an Ethernet  
socket on one of the HELIX DN9340E/DN9344E units (daisy chain), or an Ethernet switch or hub,  
depending on system configuration.  
Note If Solo Tracking input is required, the first HELIX must be a DN9340E.  
10.3.2  
Ethernet connection – wireless option  
The system set up for the wireless option Ethernet connection is via an Ethernet cable connected to  
the network socket of the wireless access point. From there it can be connected to an Ethernet  
socket on one of the HELIX DN9340E/DN9344E units (daisy chain), or an Ethernet switch or hub,  
depending on system configuration. The system is then operated remotely from a tablet or laptop  
PC.  
Note If Solo Tracking input is required, the first HELIX must be a DN9340E.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
10.3.3  
Configuring the DN9340E for Network Communication  
Before you can control the DN9340E from your remote software, there are number of configuration  
settings to check on the DN9340E unit(s):  
First, you must configure the system devices (the laptop/PC and HELIX DN9340E units) to  
communicate with each other using TCP/IP protocol. This is done by assigning them unique  
IP addresses on the network. For more details on setting the IP Address and Subnet Mask on  
the DN9340E, see Section 7.11.  
Having completed the Ethernet setup, now activate remote comms on each DN9340E unit.  
Set each unit to receive and transmit data on a unique Comms channel following the  
instructions in Section 7.2.  
Note that when you press HOME to confirm channel, the display  
updates as shown opposite.  
The final stage is to configure the Elgar Library Manager software to communicate with the  
DN9340E unit(s) on the correct ports with corresponding IP Addresses, etc. For more  
information on configuring the Elgar Library Manager and HELIX DN9340E RCS add-in  
software, please refer to the relevant documentation.  
Note that once remote communications are established, the DN9340E display updates to show the  
Network status as Yes, and that Data is being received as indicated by a rotating line on the display.  
10.3.4  
Configuring the DN9344E for Network Communication  
You must also configure similar settings on the DN9344E unit(s):  
Assign unique TC/IP addresses to each unit on the network. For more details on setting the  
IP Address and Subnet Mask on the DN9344E, see Section 15.6.  
Activate remote comms on each DN9344E unit. Set each unit to receive and transmit data on  
a unique Comms channel following the instructions in Section 15.2.  
The final stage is to configure the Elgar Library Manager software to communicate with the  
DN9344E unit(s) on the correct ports with corresponding IP Addresses, etc. For more  
information on configuring the Elgar Library Manager and HELIX DN9344E RCS add-in  
software, please refer to the relevant documentation.  
Note that once remote communications are established, the DN9344E front panel indicates that Data  
is being received by the flashing NETWORK LED.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
10.4.Serial Connection (Option)  
There is an option to control your system remotely from a laptop/ PC via the RS-232 connection (the  
“PC PORT”) on the front panel of the first HELIX DN9340E/DN9344E unit. It is possible to connect to  
other HELIX DN9340E/DN9344E units from the rear Ethernet port(s) when using a serial connection,  
but note that this will be slower than using Ethernet.  
10.4.1 Serial connection details  
The system set up for serial connection is illustrated below.  
10.4.2 Connection and Configuration Procedure  
The HELIX RCS laptop/PC is connected to the daisy chain as follows:  
To connect, set up and configure your system for serial operation  
1
Connect the HELIX DN9340E/DN9344E units in a daisy chain configuration, see  
Section 10.2.1.  
2
Power up the HELIX DN9340E/DN9344E units and assign each one a unique Comms  
channel, as described in Sections 7.2 and 15.2.  
Note  
The order of the addresses does not need to mirror the order of the daisy chain  
networking, but each unit MUST have a unique comms channel address.  
3
Referring to the following table, connect your laptop/PC to the first HELIX unit in the  
daisy chain.  
HELIX DN9340E Unit  
Connection  
Laptop/PC  
Connection  
Cable/Converter Required  
RS-232 input to front panel  
“PC PORT”  
D9 COM port  
USB port  
Host cable  
KK systems USB/232 converter plus host cable  
For details of converters plese refer to  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9344E  
11. FRONT PANEL: DN9344E  
11.1.Alphanumeric displays, SETUP, Metering and Power  
5
7
6
2
3
4
1
1
2
3
4
1
Alphanumeric Displays  
for sections 1 and 2  
The large red alphanumeric displays can be used to show  
electronic scribble-strip information, Last Memory Recalled  
or Set Up menu options. There are two displays, one per  
section.  
2
3
Input Metering for  
sections 1 and 2  
Incorporating multi-point clip indication. Meter indicates the  
level immediately after the input gain trim.  
Four separate meters are provided, to allow continuous  
monitoring of all dynamic EQ sections.  
Dynamic EQ  
Metering for sections 1  
and 2  
4
5
Output Metering for  
sections 1 and 2  
Incorporating multi-point clip indication. Meter indicates the  
actual output level from the unit, while the red clip light  
indicates internal clipping, which is monitored at every  
internal processing stage.  
SETUP button  
Press and hold for one second to access Set Up menu, then  
press to step through the Set Up pages.  
6
7
Power Switch  
Power on.  
Power ON indication  
Power indication.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9344E  
11.2.Indicators, Up and Down Buttons, PC Port and Scribble Strips.  
1
2
1
1
1
2
3
1
3
4
5
6
3
4
Remote Control Active  
indicators (green) for  
This indicator shows that the master unit is currently  
controlling this channel by remote control. Green lamps are  
Channel 1A, 1B, 2A and often referred to as the “me” lights.  
2B.  
2
Display mode  
When illuminated these indicate that the large red  
indicators (blue) for  
sections 1 and 2.  
alphanumeric displays are now showing Last Memory  
Recalled and Communications Mode. When extinguished,  
the displays are showing electronic scribble-strip names.  
There are two indicators, one per section.  
3
4
5
6
Scribble-strip areas  
Allow easy labelling of the unit. Use only chinagraph pencils  
to avoid permanently marking the unit. Remove chinagraph  
markings by wiping with a soft cloth. Do not use solvents as  
these may damage the surface.  
UP and DOWN buttons for  
sections 1 and 2.  
Used to select various set up menu options including the  
communications channel for remote control and also contact  
closure mode. Active only when in the SETUP menu. (Press  
and hold SETUP to enter this menu).  
PC port connector  
8-pin mini-DIN socket for connecting to an RS-232 serial  
port on a PC or other remote control device. (Ethercon  
connectors are provided on the rear panel for remote control  
via Ethernet.)  
Communictions traffic  
indicators  
These indicate when there is communications activity on any  
of the external interfaces. Transmit and receive data LEDs  
are shown for NETWORK (rear panel Ethernet data), DATA  
(front panel RS-232 PC port data) and RELAY (the rear panel  
RELAY contact closure input). In addition, IP ADDR and  
SUBNET LEDs illuminate when the IP Address or Subnet mask  
setup menus are selected.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls, Connectors, Indicators: DN9344E  
12. REAR PANEL: DN9344E  
1
2
7
4
3
5
4
3
6
4
3
5
4
3
1
2
Mains inlet socket  
Ethernet  
Mains inlet unit is auto sensing over the range 100-240V AC.  
2-port Ethernet switch for remote control using Cat-5  
cabling.  
3
Inputs 1A, 1B, 2A and 2B Analogue – electronically balanced XLR audio input sockets  
Pinouts: Pin 1 Screen  
Pin 2 Hot  
Pin 3 Return  
Digital – inputs 1A and 2A support incoming 96kHz AES/EBU  
signals (AES IN 1 and AES IN 2). Note that when digital input is  
selected, inputs 1B and 2B are inactive.  
AES/EBU is 110 Ohms. Sample rate converters (SRCs)  
support incoming signals at sampling frequencies from  
32kHz to 96kHz ±12.5% while allowing the unit to operate  
internally at 48kHz. An SRC bypass facility is available for  
48kHz operation, to eliminate the propagation delay through  
the SRC.  
Pinouts: Pin 1 Screen  
Pin 2 Data +  
Pin 3 Data -  
4
5
Analogue Outputs 1A,  
1B, 2A and 2B  
Electronically balanced XLR audio output plugs  
Pinouts: Pin 1 Screen  
Pin 2 Hot  
Pin 3 Return  
Digital Outputs 1 and 2  
Word clock Input  
Digital AES/EBU output for channels 1A/1B and 2A/2B.  
AES/EBU is 110 Ohms.  
6
7
A word clock input is provided for synchronisation purposes.  
Contact Closure (RELAY)  
interface  
This allows a simple contact closure to recall memories on  
the unit. Pin connections are as follows:  
Pin 1 - recall Preset / User 1 on Section 1 (the left-hand unit)  
Pin 2 - recall Preset / User 2 on Section 1 (the left-hand unit)  
Pin 3 - recall Preset / User 3 on Section 1 (the left-hand unit)  
Pin 4 - recall Preset / User 4 on Section 1 (the left-hand unit)  
Pin 5 - recall Preset / User 1 on Section 2 (the right-hand unit)  
Pin 6 - recall Preset / User 2 on Section 2 (the right-hand unit)  
Pin 7 - recall Preset / User 3 on Section 2 (the right-hand unit)  
Pin 8 - recall Preset / User 4 on Section 2 (the right-hand unit)  
Pin 9 - common  
Momentarily connect pin 9 to the appropriate other pin (1-8)  
to perform a recall.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Signal Flow: DN9344E  
13. SIGNAL FLOW: DN9344E  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9344E  
14. OPERATION: DN9344E  
The DN9344E is designed to be remotely controlled using one of the following methods:  
Remote control from a master DN9340E unit. For details, see Section 9.  
Remote control from a PC running the Elgar Library Manager and HELIX DN9344E RCS  
add-in software. For details, see Section 10.  
Relay operation – where DN9344E memories may be recalled using a simple contact  
closure mechanism. For details, see Section 15.2.  
15. SET UP MENU: DN9344E  
15.1.General  
The DN9344E provides various set up options for adapting the operation of the unit to best suit your  
operational requirements and preferences, as follows:  
Comms channel setting for remote control operation (Page 1)  
Password Page (Page 2)  
Analogue/Digital input source and clock reference options (Pages 3 and 4)  
Digital output clock reference options (Pages 5 and 6)  
Ethernet settings for remote control operation (Pages 7 and 8)  
These options are programmed in the Set Up menu and are described below in menu order.  
To access the Set Up menu pages  
At the Home page press and hold the SET UP button to open the menu.  
Press the SET UP button repeatedly to step through the pages in turn.  
Note that this menu does not ‘cycle’. On completing the set up, the menu returns to the Home page.  
15.2.Remote Comms channels (Page 1)  
The Comms page lets you select the communications channel on which the unit will send/receive data  
to/from a controlling PC or master DN9340E unit. Note that each DN9344 has TWO independent  
communications channels (one for Section 1 and one for Section 2) as it contains the equivalent of  
TWO DN9340 master units.  
Note that when using Ethernet communication, you will need to set up the unit’s IP address and  
Subnet mask before selecting the comms channel, see Section 15.6 for further details.  
In addition, this menu provides the option to enable the DN9344E for relay operation. This allows  
memories to be recalled using a simple contact closure mechanism.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9344E  
To select a remote communications channel  
1
2
Press and hold the SET UP button to open the Comms menu. Note that the red alphanumeric  
displays are now showing Last Recalled Memory and Communication (COMMS) mode. The  
blue display mode indicator illuminates to emphasise this fact. The UP and DOWN buttons  
illuminate to show that they are now active.  
Press UP and DOWN on the left-hand half of the unit (Section 1) to select the desired  
communications channel. There are 32 possible channels available. Each unit (including the  
master) MUST have a unique channel number or the system will not work correctly.  
3
Now press the UP and DOWN buttons on the right-hand half of the unit to select its own,  
independent communications channel. The reason for having two separate channel numbers  
within one unit is that the DN9344E is seen by the system management software as  
representing two individual DN9340E units, each with two channels. This allows DN9340E  
and DN9344E units to be freely swapped in and out of the system without changing the  
mapping between audio channels and communications channels. In other words, every  
stereo pair of audio channels has a communications address, irrespective of whether it is a  
DN9340E or half a DN9344E.  
4
5
Press SETUP to confirm (unit will display password menu).  
Press SETUP to exit.  
The red alphanumeric displays are now showing the three-character name for each audio channel.  
These are set from the master unit. If no names have been entered, the display will show “---”  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9344E  
To enable the Contact Closure (RELAY) mode  
1
Press and hold the SETUP button to enter the SETUP menu. Note that the red alphanumeric  
displays are now showing Last Recalled Memory and Communication (COMMS) mode. The  
blue display mode indicator lights to emphasise this fact. The UP and DOWN buttons illuminate  
to show that they are now active.  
2
Use the UP and DOWN buttons to select either “RLP” or “RLU” for preset or user memory recall  
modes.  
The left-hand (Section 1) and right-hand (Section 2) parts of the unit are entirely  
independent. It is possible to use either RELAY mode on Section 1 while Section 2 is  
operating in remote control mode, or vice versa. Equally, both sections can operate in either  
RELAY mode if desired.  
Note  
3
4
Press SETUP to confirm (unit will display password menu).  
Press SETUP to exit.  
Memory recalls are now performed by an external switch or relay that momentarily connects pin 9 of  
the RELAY connector to one of the other pins.  
Function assignments are as follows:  
-
-
-
-
-
-
-
-
-
Pin 1: recall Preset / User 1 on Section 1 (the left-hand unit)  
Pin 2: recall Preset / User 2 on Section 1 (the left-hand unit)  
Pin 3: recall Preset / User 3 on Section 1 (the left-hand unit)  
Pin 4: recall Preset / User 4 on Section 1 (the left-hand unit)  
Pin 5: recall Preset / User 1 on Section 2 (the right-hand unit)  
Pin 6: recall Preset / User 2 on Section 2 (the right-hand unit)  
Pin 7: recall Preset / User 3 on Section 2 (the right-hand unit)  
Pin 8: recall Preset / User 4 on Section 2 (the right-hand unit)  
Pin 9: common  
Momentarily connect pin 9 to the appropriate other pin (1-8) to perform a recall.  
To disable remote communications and relay operation  
1
2
3
4
Press and hold the SETUP button to enter the SETUP menu.  
Use the UP and DOWN buttons to select OFF for each section of the unit.  
Press SETUP to confirm (unit will display password menu).  
Press SETUP to exit.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9344E  
15.3.Password Page (Page 2)  
This allows the presets to be password protected to prevent unauthorised editing. The password is  
six characters long.  
To set a password  
1
Press and hold the SETUP button to open the Comms menu. Press SET UP again.  
2
Press UP on the right-hand section of the unit (Section 2) to highlight the furthest left digit in  
that section; a dot will appear at the base of the digit to show that is selected. Set the  
desired character by using the UP and DOWN buttons in the right-hand section.  
3
4
Using the UP and DOWN buttons in the left-hand section to move to the next/previous  
character, set the other five remaining characters to complete the password.  
When you are satisfied with your password (please make sure you don’t forget it), press  
SETUP. You can then store the password (“OK SET”) by pressing the UP button in the left-hand  
section. Or, you can exit without saving (“QUIT”) by pressing the UP button in the right-hand  
section.  
15.4.Analogue/Digital Input Select (Pages 3 and 4)  
The next two pages set the input source and clock reference for input channels 1A and 1B, and 2A  
and 2B on a paired basis due to the sharing of channels for AES/EBU inputs. Each input pair may be  
switched between analogue and digital, and the clock reference may be set to a number of options.  
Note that the default options are analogue input, with the clock reference set to internal and a  
sampling rate of 48kHz.  
To change the settings for Inputs 1A and 1B  
1
Step through the Set Up menus to the Input 1 page (“I1”) shown below:  
2
3
Use the UP and DOWN buttons on the left-hand half of the unit (Section 1) to navigate between  
each of the four display fields. For example, to change the input from analogue to digital,  
move across to the “ALG” field.  
Now use the UP and DOWN buttons on the right-hand half of the unit (Section 2) to change to a  
new option, for example select “DIG”.  
4
5
Press SETUP to confirm (unit will display password menu).  
Press SETUP to exit.  
Note  
The available options for each field may be affected by the set-up of  
other fields.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9344E  
15.5.Digital Output Clock Select (Pages 5 and 6)  
The next two pages select the clock reference for the digital AES/EBU outputs 1 and 2. Note that the  
output clock reference settings are independent of sampling frequency. The available options are:  
‘INT’ – the digital output is locked to the DN9344E’s internal system clock. Note that this is  
the default setting.  
‘WCK’ – the digital output is locked to the word clock reference input located on the rear  
panel of the unit.  
‘I1D’ or ‘I2D’ – the digital output is locked to the digital input channel’s incoming AES/EBU bit  
stream from either input 1 or input 2.  
Note  
The available options for may be affected by the set-up of the input  
source and clock selects, see Appendix A for details.  
To change the settings for Output 1  
1
Step through the Set Up menus to the Output 1 page (“O1”) shown below:  
2
3
Use the UP and DOWN buttons on the left-hand half of the unit (Section 1) to navigate between  
each of the four display fields.  
Now use the UP and DOWN buttons on the right-hand half of the unit (Section 2) to change to a  
new option.  
4
5
Press SETUP to confirm (unit will display password menu).  
Press SETUP to exit.  
Note  
The available options for each field may be affected by the set-up of  
other fields.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation: DN9344E  
15.6.Ethernet Settings (Page 7)  
When controlling the DN9340E unit remotely via Ethernet, the unit requires an individual IP Address  
and Subnet Mask to be set. For more information on remote control set ups, see Sections 9 and 10.  
The IP Address is entered manually on each unit in the network using the DN9344E’s front panel  
controls.  
To change the IP address  
1
2
Use the UP and DOWN buttons on the left-hand half of the unit (Section 1) to navigate between  
each of the four display fields.  
Now use the UP and DOWN buttons on the right-hand half of the unit (Section 2) to set a value  
between 0-255.  
3
4
Press SETUP to confirm (unit will display password menu).  
Press SETUP to exit.  
It is important that all units and the controlling PC have a unique IP Address in  
order for the network to function correctly.  
Note  
After setting the IP address you need to check the Ethernet IP Address Subnet mask on each unit,  
see Section 15.6.2.  
15.6.2  
Subnet Mask (Page 8)  
When the IP Address is set manually, it is necessary to check the Ethernet IP Address Subnet mask  
on each unit. The default subnet mask is 255.255.0.0.  
To change the Subnet Mask  
1
2
Use the UP and DOWN buttons on the left-hand half of the unit (Section 1) to navigate between  
each of the four display fields.  
Now use the UP and DOWN buttons on the right-hand half of the unit (Section 2) to set the  
value between 0-255.  
3
4
Press SETUP to confirm (unit will display password menu).  
Press SETUP to exit.  
It is important that all units and controlling PCs have the same Subnet Mask to  
function correctly. You may want to modify Subnet Masks where one area of the  
network is required to be ‘hidden’ from another, for example, in an installation with  
one network but multiple auditoriums. For more information on configuring your  
network, please see the HELIX DN9340E/DN9344E RCS User Guide.  
Note  
For more information on remote control setups, see Sections 9 and 10.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Notes  
16. APPLICATION NOTES  
16.1. Dynamic EQ  
Over the years a number of professional audio products have provided dynamic equalisation functions  
of various types. What all these systems have in common is that the frequency response of the  
device varies depending on the signal level. Many units are based on compressor/expander  
technology with frequency selection, and the controls often resemble those of a dynamics processor.  
The system developed by the Klark Teknik research and development team for the Helix series is  
rather different. It draws on KT's unrivalled experience in equalisation, and uses the signal level to  
directly control parametric equalisers. This purely EQ-based solution allows simple controls that  
directly relate to the signal levels. As a result, it is very easy to set the point at which the dynamic  
EQ starts to operate, and also to set precisely its maximum effect. We refer to this technique as  
“Threshold Dependent Equalisation”.  
In order to understand the operation, let us first consider a conventional parametric EQ section  
(Figure 1). The three controls available to us are frequency, Q (or bandwidth), and the amount of cut  
or boost.  
This shows a series of responses for the parametric EQ with different input levels. As expected, there  
is no change in the shape of the curve with different input levels. If the input is 10dB louder, the  
output is 10dB louder at every frequency.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Notes  
If we now replace the parametric with a Helix equaliser and select the dynamic EQ, we have some  
additional controls. Frequency and Q controls are as before, but now we have two pairs of controls  
replacing the single cut and boost control; these are [low threshold] / [low level], and [high  
threshold] / [high level]. If we set the frequency and Q controls to the area that we wish to control,  
then the processor will monitor the signal level in that frequency range. If the signal level in this part  
of the spectrum is below the [low threshold] setting, then the unit considers this a ‘quiet’ signal. The  
EQ applied to the signal will be controlled by the [low level] control. If the signal level is above the  
[high threshold] level, then the unit considers this a ‘loud’ signal, and will apply the amount of EQ set  
by the [high level] control. If the signal level is between the two thresholds, then the equaliser will  
seamlessly morph between the two equaliser settings in real time. Manual control over attack and  
release times is available to set the speed of response to suit the application.  
As an example, consider Figure 2, which shows the Helix applying a boost at low signal levels which is  
automatically ‘wound out’ at high level.  
In this example, [low threshold] is -20dBu, [low level] is +12dB, [high threshold] is set to -5dBu, and  
[high level] is 0dB. Thus, the lowest trace shows an input at -25dBu with a standard parametric  
boost of +12dB at 1kHz. The -20dBu trace shows an identical response, as expected. However, once  
above this level the filter gradually fades out with increasing signal, until at all levels above 0dBu the  
response is flat.  
The shape of the curves for -5dBu and -10dBu require some explanation. These appear as they do  
because of the nature of the frequency sweep measurement. The Helix equaliser uses a copy of the  
actual filter in use for its level calculation, so that, depending on the Q of the filter, our input signals  
are ‘ignored’ as we move away from the centre frequency by the correct amount. Thus, as the sweep  
measurement moves across the centre frequency (1kHz in this case), the dynamic EQ is ramping  
smoothly in and out again, leading to the curves in Figure 2. Note that if the level is outside the  
range specified by the two thresholds, the unit behaves like a fixed parametric EQ. This means that  
we do not have to guess how much EQ will eventually be applied - it is explicitly set in advance.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Notes  
Without changing modes or making any other selections, we can make the unit operate ‘the other  
way up’ just by selecting suitable values for the two thresholds and levels see Figure 3.  
In this case, [low threshold] is -20dBu, [low level] is 0dB, [high threshold] is -5dBu, and [high level]  
is +12dB, so that instead of cutting this frequency range as the level increases, we are now boosting  
it. Again, we have precise control over the maximum amount of boost that will be applied, and the  
level at which this will occur. Note the shape of the curve for -5dBu, which has ‘expected values’  
outside the filter range and at the centre frequency, but intermediate values that show the EQ  
ramping in and out either side of the centre frequency.  
Needless to say, there is no requirement for one of the levels to be 0dB. Figure 4 shows the  
transition from a +12dB boost at low level to a -12dB cut at high levels. Again, the intermediate  
curves show the effect of the sweep signal moving in and out of the ‘area of interest’ of the level  
detector as the curve is formed.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Notes  
16.2.What do we mean by all these Q types?  
The “Q” of an audio equaliser describes the steepness of the filter - the degree to which it will affect  
signals either side of its nominal or “centre” frequency. In general, the Q of a peaking filter is defined  
mathematically:  
as,  
where the bandwidth (in Hz) is the range of frequencies affected by the  
filter.  
Because the frequency response of such a filter is a smooth curve (not a sharp “brick wall” filter like  
the ones in an analogue-to-digital converter) we have to decide how we choose to define the  
bandwidth. The established convention is that we use the bandwidth to the “-3dB” points on either  
side of the centre frequency, where the gain is 3dB less than the maximum gain.  
In the example above, the filter is centred on 1kHz, the lower 3dB point is at approximately 800Hz,  
and the upper one is at approximately 1.25kHz.  
Therefore, this filter has a Q of:  
In a typical parametric equaliser (and in the case of the Helix system the graphic and dynamic  
sections too) we have a manual control for the Q of the filter, and this allows us to set any Q that we  
require. In general, high-Q, narrow filters are used for notching out problem frequencies without  
affecting the programme material too much. While gentler low-Q filters are useful for adjusting the  
tonal balance. In the case of graphic equalisers there is another issue - that of interaction between  
adjacent bands. In general, lower-Q filters will blend together more smoothly, but higher-Q filters  
provide more selective control of problems - at the expense of more frequency response ripple.  
So far so simple - but why the different types? This is due to the way in which the Q of the filter  
varies (or not) when the gain control is adjusted. There are three modes available in the Helix  
system, which we term Proportional, Constant, and Symmetrical Q.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Notes  
Proportional Q  
Proportional Q is the mode of operation familiar to users of the Klark Teknik analogue graphic  
equalisers, such as the DN360. As the amount of cut or boost is increased, the Q also increases.  
This has the effect of making the equaliser “focus” more tightly as the amount of EQ is increased.  
This allows a fairly low-Q filter at small cut and boost settings, providing gentle control of tonal  
balance and low ripple. At high gain settings, a proportional-Q equaliser “automatically” increases Q  
for more dramatic problem solving such as suppression of feedback or unwanted resonances. In the  
interests of clarity, the Q setting shown on the display is the Q at full cut or boost - the Q at lower  
gain settings will be lower than that shown on the panel.  
Constant Q  
A constant Q equaliser has the same Q at all cut and boost settings. In other words, the bandwidth  
between the 3dB points does not change at all as the gain is adjusted. The really important thing to  
notice about this is that the resulting frequency response is NOT symmetrical in cut and boost. This  
is because of the definition of Q, which is based on the 3dB points relative to maximum gain. The  
maximum gain of the filter when in cut is, of course, 0dB, and the bandwidth is determined by the  
-3dB points relative to 0dB and NOT relative to the minimum gain (at the centre frequency). This  
makes a lot of sense musically too - if you listen to a music signal and apply a notch filter, and then  
change the shape of the curve around the minimum gain (centre) point, it will make little difference  
to the sound (since that area is already attenuated a lot). However, if you change the curve around  
the 3dB points, this will affect the sound much more, as more or less of the signal “falls into” the  
notch. It is this bandwidth that the constant-Q filter is keeping constant. Note that many equalisers  
that are described as “Constant Q” by their manufacturers do NOT fall into this category, and are  
what we would term symmetrical-Q designs.  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Notes  
Symmetrical Q  
This class of equaliser has the same curves in boost as the constant-Q type, but then has cut  
responses that are symmetrical with the boost ones. In other words, the bandwidth in cut is defined  
not according to our usual definition of Q (see constant-Q above) but as “the point were the signal is  
cut by 3dB less than the maximum cut”. Most equalisers described by their manufacturers as  
“Constant Q” in fact produce symmetrical responses.  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application Notes  
16.3.What is AES/EBU?  
AES/EBU refers to the professional digital audio transmission system, jointly specified by the Audio  
Engineering Society (AES) and the European Broadcast Union (EBU), which allows the transmission of  
two channels down a shielded twisted pair cable using time division multiplexing (TDM) with one  
sample from each channel being transmitted within the sample period of the system. The system  
was published as the AES3 standard.  
By virtue of TDM, one XLR cable carrying AES/EBU data can replace two regular analogue connections  
- hence only single in/out connectors are required on the AES/EBU Unit. The clock for the data  
transmission, which is embedded in the incoming data using a process known as bi-phase mark  
encoding or Manchester encoding, can also be used as the clock source for the master clock within a  
unit equipped with an AES/EBU interface. This is the preferred mode of operation, as it guarantees  
that the unit is synchronised to the incoming data stream.  
For large digital transmission systems using AES/EBU interfaces, such as those encountered in  
broadcast and studio installations, a clock signal operating at the sampling frequency can be  
distributed to all units separately to the AES/EBU signals. This is generally known as 'word clock' and  
allows all connected units to be synchronised on a sample-accurate basis. Word clock is most  
commonly connected using 75 Ohm, BNC connectors.  
All DN9000E series Helix units feature sample rate converters (SRCs) on their AES/EBU inputs and, in  
the case of the DN9340E Helix Dual EQ and DN9344 Quad EQ, SRCs on their AES/EBU outputs as  
well. This allows the units to interface to AES/EBU systems operating up to 96kHz, including the  
Midas XL8 Live Performance System.  
The SRCs may be bypassed in 44.1 kHz and 48 kHz AES/EBU synchronised transmission systems  
(48kHz only in the case of the DN9848E System Controller), which eliminates propagation delays  
introduced by the SRCs and reduces the input-to-output latency of the signal paths to that incurred  
by the actual digital signal processing algorithms.  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specification: DN9340E  
17. TECHNICAL SPECIFICATION  
17.1.DN9340E  
Analogue Inputs  
Two  
Type  
Electronically balanced (pin 2 hot)  
20k  
>80dB @ 1kHz  
Impedance ()  
Common Mode Rejection  
Digital Inputs  
One 2-Channel Input  
Type  
AES/EBU  
110  
44.1kHz, 48kHz, 88.2kHz*, 96kHz*  
24-bit or 16-bit  
Impedance ()  
Sample Rate  
Word Length  
* SRC Input at these sample rates  
Word Clock Input  
One  
Type  
Impedance ()  
BNC  
75  
Analogue Outputs  
Two  
Type  
Maximum Level  
Electronically balanced (pin 2 hot)  
+21dBu into >2k  
Digital Outputs  
One 2-Channel Output  
Type  
AES/EBU  
110  
44.1kHz, 48kHz  
24-bit  
Impedance ()  
Sample Rate  
Word Length  
Performance  
Frequency response  
(20Hz to 20kHz)  
Distortion (THD+N) @ +4dBu  
(20Hz to 20 kHz)  
Dynamic range  
±0.5dB with all filters and EQ flat (relative to frequency response at 1kHz)  
<0.01%  
115dB  
(20Hz-20kHz unweighted)  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specification: DN9340E  
Processing (Per Channel)  
Input Gain  
+12dB to 40dB in 0.1dB steps plus Off  
Delay  
0-1 second (342.25 m or 333'10” at 20C in 20.8µs steps)  
Filters  
Types  
4 Filters (max)  
Low Pass, High Pass, Low Shelf, High Shelf, Notch  
Dynamic EQ  
Range  
Responses  
2 Bands (max)  
±12dB  
Proportional, Constant, Reciprocal  
Parametric EQ  
Range  
Responses  
12 Bands (max)  
12dB  
Proportional, Constant, Reciprocal  
Graphic EQ  
Range  
Responses  
31 Bands On ISO standard frequencies  
±12dB  
Proportional, Constant, Reciprocal, DN27, DN360  
Power Requirements  
Voltage  
Consumption  
90V to 250V a.c. 50/60 Hz  
60W  
Terminations  
Audio inputs/outputs  
Ethernet inputs/outputs  
RS-232  
3-pin XLR  
Ethercon  
8-pin Mini-DIN socket (front)  
9-pin D-type (rear)  
3-pin IEC  
Power  
Dimensions and Weight  
Width  
Height  
Depth  
Nett Weight  
Shipping Weight  
483 mm (19inch)  
88 mm (3.5 inch) 2RU High  
303 mm (12 inch)  
5.5 kg  
7.0 kg  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specification: DN9344E  
17.2.DN9344E  
Analogue Inputs  
Four  
Type  
Impedance ()  
Electronically balanced (pin 2 hot)  
20k  
Common Mode Rejection  
>80dB @ 1kHz  
Digital Inputs  
Two 2-Channel Inputs  
Type  
AES/EBU  
110  
44.1kHz, 48kHz, 88.2kHz*, 96kHz*  
24-bit or 16-bit  
Impedance ()  
Sample Rate  
Word Length  
* SRC Input at these sample rates  
Word Clock Input  
One  
Type  
Impedance ()  
BNC  
75  
Analogue Outputs  
Four  
Type  
Maximum Level  
Electronically balanced (pin 2 hot)  
+21dBu into >2k  
Digital Outputs  
Two 2-Channel Outputs  
Type  
AES/EBU  
110  
44.1kHz, 48kHz  
24-bit  
Impedance ()  
Sample Rate  
Word Length  
Performance  
Frequency response  
(20Hz to 20kHz)  
Distortion (THD+N) @ +4dBu  
(20Hz to 20 kHz)  
±0.5dB with all filters and EQ flat (relative to frequency response at 1kHz)  
<0.01%  
115dB  
Dynamic range  
(20Hz-20kHz unweighted)  
Processing (Per Channel)  
Input Gain  
+12dB to 40dB in 0.1dB steps plus Off  
Delay  
0-1 second (342.25 m or 333'10” at 20C in 20.8µs steps)  
Filters  
Types  
4 Filters (max)  
Low Pass, High Pass, Low Shelf, High Shelf, Notch  
Dynamic EQ  
Range  
Responses  
2 Bands (max)  
12dB  
Proportional, Constant, Reciprocal  
Parametric EQ  
Range  
Responses  
12 Bands (max)  
12dB  
Proportional, Constant, Reciprocal  
Graphic EQ  
Range  
Responses  
31 Bands On ISO standard frequencies  
12dB  
Proportional, Constant, Reciprocal, DN27, DN360  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specification: DN9344E  
Power Requirements  
Voltage  
Consumption  
90V to 250V a.c. 50/60 Hz  
60W  
Terminations  
Audio inputs/outputs  
Ethernet inputs/outputs  
RS-232  
Relay Socket  
Power  
3-pin XLR  
Ethercon  
8-pin Mini-DIN socket (front)  
9-pin D-type (rear)  
3-pin IEC  
Dimensions and Weight  
Width  
Height  
Depth  
Nett Weight  
Shipping Weight  
483 mm (19 inch)  
44 mm (1.75 inch) 1RU High  
287 mm (12 inch)  
5.5 kg  
7.0 kg  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Information  
18. SERVICE INFORMATION  
18.1.Battery  
This unit contains a battery. Do not expose unit or batteries to excessive heat, such as may be  
caused by sunshine, fire or the like.  
18.1.1  
Replacement  
Caution!:  
Danger of explosion if battery is incorrectly placed. Replace only with the same or equivalent type  
recommended by the manufacturer. Discard used batteries according to the manufacturer’s  
instruction.  
Advarsel!:  
Lithiumbatteri. Ekxplosionsfare ved feijlagtig handtering af samme fabrikat og type. Lever det brugte  
batteri tilbage till leverandoren.  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer Dryer W 161 User Manual
Jackson Gas Heater Heater Replacement User Manual
JobSite Systems Stereo Amplifier S 6VC User Manual
JVC Speaker System CA UXGD7 User Manual
Kambrook Fan KFH520 User Manual
Karcher Pressure Washer K 568 M User Manual
Kawasaki Motorized Toy Car 78410 User Manual
Kenwood Security Camera DPC 361 User Manual
Kenwood Two Way Radio TH G71A User Manual
KitchenAid Cooktop W10271686C User Manual