30", 36" and 48" Wall-Mount Canopy Range Hood
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
10-7/8"
KWCU205H
KWCU265H
KWCU285H
(27.6 cm)
5-7/8"
(14.9 cm)
1" (2.5 cm) min. -
20" (50.8 cm) max.
upper chimney height
Electrical: 120-volt, 60-Hz, AC-only, 15-amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.
23" (58.4 cm) min. -
42" (106.7) max.
overall chimney
height
22" (58.9 cm)
lower
chimney
height
VENTING REQUIREMENTS
The vent system length should not
exceed the lengths shown in the
chart below.
9-1/2" (24.1 cm)
canopy height
Vertical roof venting
roof cap
3-1/4" x 10"
Vent size
3-1/4" x 10"
Maximum length
(8.3 cm x 25 cm)
through the roof
35 ft. (10.7 m)
30" hood 29-15/16" (76 cm),
36" hood 35-3/8" (89.9 cm),
48" hood 47-1/4" (120 cm)
overall width
(8.3 cm x 25 cm)
7" (17.8 cm) round
19-1/4"
(48.9 cm)
Note:
3-1/4" x 10"
40 ft. (12.2 m)
50 ft. (15.2 m)
60 ft. (18.3 m)
overall depth
(8.3 cm x 25 cm)
rectangular vent
must be used
inside chimney
cover. Round
vent will not fit
inside chimney
cover.
8" (20.3 cm) round
9" (22.9 cm) round
CABINET OPENING DIMENSIONS
To calculate the length of the system you need, add the
equivalent feet for each vent piece used in the system.
19" (48.3 cm)*
Vent Piece
3-1/4" x 10"
(8.3 cm x 25 cm)
Rectangular
7" (17.8 cm),
8" (20.3 cm) or
9" (22.9 cm) Round
13" (33 cm)
cabinet
depth
45° elbow
7.0 feet
(2.1 m)
2.5 feet
(0.8 cm)
Horizontal wall venting
90° elbow
5.0 feet
(1.5 m)
5.0 feet
(1.5 m)
30" hood 30" (76 cm),
36" hood 35-7/16" (90 cm)
48" hood 47-5/16" (120.2 cm)
min. cabinet opening widths
34-5/8"
(87.9 cm)
min.
90° flat elbow
12.0 feet
(3.7 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
through the wall
transition to round 5.0 feet
(1.5 m)
wall
cap
92-1/2"
(235 cm)
min.
24" (61 cm) min.
bottom of canopy to
cooking surface**
18" (45.7 cm)
111-1/2"
(283.2 cm)
max.
min. clearance
upper cabinet to
countertop
wall cap
0.0 feet
(0.0 m)
ceiling to
floor
3-1/4" x 10" (8.3 cm x 25 cm)
vent system
3-1/4" x 10”
(8.3 cm x 25 cm)
elbow
wall
cap
36" (91.4 cm)
base cabinet
height
6 ft. (1.8 m)
Note: Flexible vent is
Not recommended.
If it is used, each foot of
flexible vent used is
equivalent to two feet
(61 cm) of straight metal
vent when calculating
the vent system length.
(Example: A flexible
elbow equals two
2 ft.
(0.6 m)
Maximum length
= 35 ft. (10.7 m)
1 — 90° elbow
8 ft. (2.4 m) straight
1 — wall cap
=
=
=
5 ft. (1.5 m)
8 ft. (2.4 m)
0 ft. (0 m)
*
If the canopy hood is installed higher than 24" (61 cm) above the
Length of 3-1/4" x 10"
(8.3 cm x 25 cm) system = 13 ft. (4 m)
cooking surface, the middle bracket must be installed at the bottom
point of the upper chimney sleeve.
standard elbows.)
** If the canopy hood is mounted higher than 24" (61 cm) above
cooking surface, depending on ceiling height, upper chimney may
need to be cut.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 4360367 Rev. C
10-15-02