30" (76.2 CM) and 36" (91.4 CM) Retractable Downdraft Vent System
PRODUCT MODEL NUMBERS
ELECTRICAL REQUIREMENTS
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical
cIrcuit is required. Use copper wire only.
KIRD801V
KIRD861V
KIRD862V
PRODUCT DIMENSIONS
Interior-mounted blower motor model
Top trim widths:
Exterior-mounted blower motor model -
used with Part Number KPEC992M
30¹⁄₄" (76.8 cm) for 30" (76.2 cm) vent
36¹⁄₄" (92.1 cm) for 36" (91.4 cm) vent
13¹⁄₂" (34.3 cm)
retractable
vent height
¹⁄₄" (0.6 cm)
13" (33.0 cm)
1¹⁄₂" (3.8 cm)
³⁄₈" (0.95 cm)
27" (68.6 cm) for 30" (76.2 cm) vent
33" (83.8 cm) for 36" (91.4 cm) vent
6¹⁄₂"
(16.5 cm)
Terminal box cover
10" (25.4 cm)
diameter
vent collar
28³⁄₄"
(73.0 cm)
6¹⁄₂"
³⁄₄" (1.9 cm)
(16.5 cm)
13" (33.0 cm)
13" (33.0 cm)
³⁄₄"
(1.9 cm)
13" (33.0 cm)
9¹⁄₄"
(23.5 cm)
6" (15.2 cm)
diameter
vent collar
2¹⁄₈" (5.4 cm)
CABINET DIMENSIONS
Interior-mounted blower motor model
Exterior-mounted blower motor model
7⁵⁄₈" (19.4 cm)
¹⁄₂" (12.7 mm)
minimum
A= ¹⁄₂" (12.7 mm)
minimum
23³⁄₄"
(60.3 cm)
21⁵⁄₁₆"
(54.1 cm)
21⁵⁄₁₆"
(54.1 cm)
All cutouts are
for 6" (15.2 cm)
diameter vent
system.
Locate power
supply junction
box at lower
left hand
Centerline of cooktop cutout
Locate power
rear corner
supply junction
box at lower
left hand
of the cabinet.
rear corner
of the cabinet.
Page 1 of 3
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10187117
11-06-08
Download from Www.Somanuals.com. All Manuals Search And Download.
®
30" (76.2 CM) and 36" (91.4 CM) Retractable Downdraft Vent System
VENTING REQUIREMENTS
It is recommended that you use round vent instead of rectangular vent, especially
if elbows are required. If rectangular vent is required, it should be transitioned to
6" (15.2 cm) round vent as soon as possible.
Example Vent System
C
6 ft
(1.8 m)
To calculate the length of the system you need, add the equivalent feet (meters)
for each vent piece used in the system.
B
A
Maximum Length of Vent System
2 ft (0.6 m)
Vent
Length
6" (15.2 cm) round
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
35 ft (8.9 m)
35 ft (8.9 m)
D
A. Blower motor
B. Transition
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
C. 90° elbows
D. 6" backdraft damper (supplied)
Vent Piece
6" (15.2 cm) Round
IMPORTANT: Make sure there is proper clearance within the wall or
45° elbow
2.5 ft
(0.8 m)
floor before making exhaust vent cutouts.
Use heavy (rigid) metal vent.
Venting system must terminate to the outside.
Do not terminate the vent system in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Do not install 2 elbows together.
90° elbow
5.0 ft
(1.5 m)
Do not use plastic or metal foil vent.
The length of vent system and number of elbows should be kept to a
minimum to provide efficient performance.
6" (15.2 cm)
wall cap
0.0 ft
(0.0 m)
Use no more than three 90° elbows
Make sure there is a minimum of 24" (61 cm) of straight vent between
the elbows if more than one elbow is used.
Use clamps to seal all joints in the vent system.
Use caulking tape to seal the exterior wall or floor opening around cap.
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft
to 6" (15.2 cm) transition
(1.4 m)
Do not cut joist or stud. If vent cutout falls over a joist or stud, a
supporting frame must be constructed.
Flexible metal vent is not recommended. If it is used, calculate each foot
of flexible vent as 2 ft (0.6 m) of rigid metal vent. Flexible elbows count
twice as much as standard elbows.
6" (15.2 cm) to 3¹⁄₄" x 10"
(8.3 cm x 25.4 cm) transition
1 ft
(0.3 m)
Recommended vent system length:
For either interior-mounted or exterior-mounted blower installations, the
vent system length should not exceed the maximum lengths listed in the
Maximum Length of Vent System chart.
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft
to 6" (15.2 cm) 90° elbow
transition
(1.5 m)
6" (15.2 cm) to 3¹⁄₄" x 10"
5.0 ft
(8.3 cm x 25.4 cm) 90° elbow (1.5 m)
transition
Page 3 of 3
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10187117
11-06-08
Download from Www.Somanuals.com. All Manuals Search And Download.
|