30" (76.2 cm) Double Oven Dual Fuel Range
PRODUCT MODEL NUMBERS
KSDG950E KSEG950E
PRODUCT DIMENSIONS
This manual covers several models. Your model may appear
different from the models depicted. Dimensions given are
maximum dimensions across all models.
GAS SUPPLY REQUIREMENTS
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must conform
with American National Standard, National Fuel Gas Code ANSI Z223.1
– latest edition or CAN/CGA B149 – latest edition.
B
C
A
IMPORTANT: Leak testing of the range must be conducted according
to the manufacturer’s instructions.
Type of Gas:
Natural Gas:
This range is design-certified by CSA International for use with Natural
gas or, after proper conversion, for use with LP gas.
D
• This range is factory-set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate located on the
oven frame behind the top right-hand side of the oven door has
information on the types of gas that can be used. If the types of gas
listed do not include the type of gas available, check with the local
gas supplier.
E
LP Gas Conversion:
Conversion must be done by a qualified service technician. No attempt
shall be made to convert the appliance from the gas specified on the
model/serial/rating plate for use with a different gas without consulting
the serving gas supplier. See “Gas Conversions” section.
F
A. 1³⁄16" (3.0 cm) height from cooktop to top of vent
B. 297⁄8" (75.9 cm)
C. Model/serial/rating plate (located behind the oven door on the top
right-hand side of the oven frame)
D. 36" (91.4 cm) height to top of cooktop edge with leveling legs
screwed in all the way*
E. 285⁄16" (71.9 cm) max. depth from front of console to back of range
F. 287⁄8" (73.3 cm) max. depth from handle to back of range
Gas Supply Line
• Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient
gas supply. With LP gas, piping or tubing size can be ½" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and materials
used in the system. NOTE: Pipe-joint compounds that resist the
action of LP gas must be used. Do not use TEFLON®† tape.
Flexible metal appliance connector:
IMPORTANT: Range must be level after installation. Follow the
instructions in the “Level Range” section. Using the cooktop as a
reference for leveling the range is not recommended.
• If local codes permit, a new CSA design-certified, 4 to 5 ft
(122 to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D.
(inside diameter), flexible metal appliance connector
may be used for connecting range to the gas supply line.
* Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
ELECTRICAL REQUIREMENTS
• A 1/2" (1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the appliance
pressure regulator.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
• Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The model/
serial/rating plate is located on the right vertical surface of the oven
door frame. Refer to the illustrations in the “Product Dimensions”
section of the “Location Requirements” section.
• Do not kink or damage the flexible metal tubing when moving
the range.
• Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve.
This valve should be located in the same room but external
to the range opening, such as an adjacent cabinet. It should
be in a location that allows ease of opening and closing. Do
not block access to shutoff valve. The valve is for turning on
or shutting off gas to the range.
• This range is manufactured with a 4-wire power supply cord rated at
240 volts, 40 amps, rated at 194°F (90°C) and investigated for use
with this range.
Specified Rating of Power
Supply Cord Kit and Curcuit
B
Range Rating*
Protection
120/240 Volts
120/208 Volts
Amps
Temp Rating
194°F (90°C)
194°F (90°C)
A
8.8 – 16.5 KW
7.8 – 12.5 KW
40 or 50
16.6 – 22.5 KW 12.6 – 18.5 KW 50
C
* The NEC calculated load is less than the total connected load listed
on the model/serial/rating plate.
A. Gas supply line
B. Shutoff valve “open” position
C. To range
Page 1 of 2
†®TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.
Ref. W10787365A
05/15