KitchenAid Cooktop KIRD862HSS User Manual

www.dexpres s .com  
DIMEN
S
I
ON E
X
P
RE
S
S  
Fax on Demand (775) 8 33-36 0 0  
This Data Sheet Includes Information On  
KitchenAid  
Product Model Number (s):  
36" Retractable Downdraft Vent System:  
KIRD862HSS  
Backsplash  
36"  
33 1/2"  
Kit: KPED890T  
2 1/8"  
Dimensions (Actual Size)  
Vent overall depth: 2 1/8"  
Vent overall width: 36"  
1 7/8"  
Vent cutout depth: 1 7/8"  
Vent cutout width: 33 1/2"  
Raised vent distance: 8 1/4"  
Vent height below countertop: 26 1/8"  
Additional Information  
Cutout vent dimensions  
Overall vent dimensions  
Cooktop  
Countertop front edge  
• Electrical requirements: Voltage 115, single phase,  
60Hz. AC. Ampere 15. Grounded circuit required.  
Locate power supply junction box at lower right corner  
of cabinet.  
36"  
Wall View  
• KitchenAid exterior power system, Part No.  
KPED890, is required to complete this system.  
• Installation location should be away from strong draft  
areas, such as windows doors and strong heating  
vents. Before making cutout, check that vent and  
cooktop location will clear cabinet walls, backsplash  
and rear wall studs inside cabinet.  
(not to scale)  
Vent  
Raised  
8 1/4"  
Countertop  
• All openings in wall or floor where vent is to be  
installed must be sealed.  
• See cooktop manufacturer's installation instructions  
for cooktop cutout depth and width.  
Vent Intake  
26 1/8"  
• NOT approved for use in mobile homes.  
• 36" minimum base cabinet is required. 3 1/2" depth  
clearance from countertop to top of cabinet drawers (or  
other obstructions in base cabinet) is required.  
• Cabinet drawer may need to be removed and  
permanent drawer front installed.  
Vent Junction Box  
• Use either 9" round (recommended) or 3 1/4" x 10"  
ductwork. Maximum length of ductwork for both 9"  
round and 3 1/4" x 10" is 55 feet.  
Cabinet Floor  
• Stainless Steel finish.  
See pages 2-3 for additional information  
Cooktop  
2 1 / 8 "  
Sid e Vie w  
(not t o scale )  
6 1 / 8 "  
Ve nt Int ake  
Subject to change without notice. This system is designed to  
be updated daily if necessary. Dimension Express is not  
responsible for use of superseded, voided, or outdated data  
sheets. Because of the difficulty or impracticability of deter-  
mining actual damages, liability of Dimension Express shall  
not exceed $50.00.  
Int e rio r ho us ing  
Copyright © Dimension Express, 2000.  
284  
• NEVER reuse Data Sheets. Data Sheets are subject to change without  
notice. Dimension Express is a FREE service bureau and is updated daily,  
it makes far more sense to spend the time necessary to request new Data  
Sheets for each project, as opposed to the problems, time, costs, and risks  
associated with reusing old Data Sheets.  
• Call Dimension Express if you have any questions at (775) 833-3633 •  
• Always refer to a current Code at a Glance or manufacturer directory •  
• Data Sheet codes change on the first of odd numbered months at 12:01am •  
BN53 • A284B149C116 • 11751 • 001311 • 215841 • 52906  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This Data Sheet Includes Information On  
KitchenAid  
www.dexpres s .com  
Product Model Number (s):  
DIMENSION EXPRESS  
Page 3  
36" Retractable Downdraft Vent System:  
KIRD862HSS  
Fax on Demand (775) 8 33-36 0 0  
Kit: KPED890T  
Cutout sizes when used with  
KitchenAid cooktops  
3/4" max. backsplash  
depth.  
D
1/2" min. to  
backsplash or rear  
wall  
C
B
A
F
Required min.  
countertop depth  
E
OA  
OA  
Model #  
A
B
C
E
F
D
Width Depth  
KGCT365G, KGCS166G, KECT336G 35 1/4" 33 1/2" 19 5/8" 2 1/8" 1 3/4" 37 1/2" 23"  
25"  
KECC562*, KECC568G*, KECC567G* 35 1/2" 33 1/2" 20 1/2" 2 1/8" 2" 37 1/2" 23 1/4" 26 7/8"  
KECS161G*  
35" 33 1/2"  
19"  
2 1/2" 3 3/8" 37 5/8" 23" 25 5/8"  
* Requires deeper than standard countertop and cabinet  
Vent cutout locations  
(not to scale)  
Ce nt e rline -  
Back edge of  
counter cutout  
Duct size: 3 1 / 4 " x 1 0 "  
3/8"  
1/4" Minimum from  
backsplash to cutout.  
C
L
2 3 9 / 1 6 "  
C
L
Vent Cutout shown  
assumes rear edge of  
cooktop overlaps edge  
of downdraft vent by 3/8"  
The center line of duct cutout  
location is 3/8" to the left of  
cutout opening centerline.  
4 1 / 8 "  
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or  
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.  
Copyright © Dimension Express, 2000.  
116  
• NEVER reuse Data Sheets. Data Sheets are subject to change without  
notice. Dimension Express is a FREE service bureau and is updated daily,  
it makes far more sense to spend the time necessary to request new Data  
Sheets for each project, as opposed to the problems, time, costs, and risks  
associated with reusing old Data Sheets.  
• Call Dimension Express if you have any questions at (775) 833-3633 •  
• Always refer to a current Code at a Glance or manufacturer directory •  
• Data Sheet codes change on the first of odd numbered months at 12:01am •  
BN53 • A284B149C116 • 11751 • 001311 • 215841 • 52906  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Init TV Video Accessories 09 0589 User Manual
Insignia Paper Shredder NS PS10CC User Manual
IRIS Indoor Furnishings E7AABB User Manual
Jacuzzi Hot Tub 6642 User Manual
JBL Car Amplifier GT5 A402 User Manual
John Deere Pressure Washer AC 2500E User Manual
Jotul Electric Heater GF 400 DV User Manual
Kawasaki Automobile Parts FE120 User Manual
Kenwood Car Stereo System DPX MP4070 User Manual
Kenwood Marine Radio TH 27A User Manual