D SERIES CONTROLLER
TROUBLESHOOTING AND
COMPONENT REPLACEMENT
MPVDCONTV113E-3
Kawa ak
s
Kawasaki Robotics (USA), Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
REVISION HISTORY
Revision Release
Number
Date
Description of Change
Initials
-0
11/20/03 Initial PDF release, based on Rev.-0 of print copy
4/27/04 Revision 1, based on Rev.-1 of print copy
9/06/05 Revision 3, based on Rev.-3 of print copy
CB/CB
-1
-3
CB/CB
CB/CB
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.0
1.1
1.2
1.2.1
TROUBLESHOOTING................................................................................... 1-2
Error Recovery ............................................................................................... 1-2
Preliminary Troubleshooting........................................................................... 1-5
Troubleshooting Common Failures................................................................. 1-5
1.2.1.1 Controller Power Cannot Be Set to ON.......................................................... 1-6
1.2.1.2 Teach Pendant Is Inoperable ......................................................................... 1-8
1.2.1.3 Motor Power Cannot Be Enabled................................................................. 1-10
1.2.1.4 Robot Does Not Move.................................................................................. 1-11
1.3
1.3.1
1.3.2
Error Codes ................................................................................................. 1-12
Error Display ................................................................................................ 1-13
Error List ...................................................................................................... 1-13
1.3.2.1 DXXXX Fatal Error Codes............................................................................ 1-14
1.3.2.2 EXXXX Non-Fatal Error Codes .................................................................... 1-59
1.3.2.3 PXXXX Operation Error Codes.................................................................. 1-159
1.3.2.4 WXXXX Mechanical/Control Warning Error Codes.................................... 1-200
1.4
Troubleshooting Flowcharts ....................................................................... 1-210
August 9, 2005
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.0 TROUBLESHOOTING
This unit provides error recovery flowcharts, error code information, and error code
troubleshooting flow charts. In addition, typical causes and remedies for the errors are
also provided.
1.1 ERROR RECOVERY
Figures 1-1 and 1-2 show troubleshooting processes that may be helpful if the controller
becomes unresponsive to commands or an error code has been encountered that
cannot be cleared. Troubleshooting should begin with confirmation of basic integrity of
the system: ensure that the power supply is on and meeting supply requirements, all
cables are correctly attached, all circuit boards are properly installed and fully seated, all
peripheral equipment is wired correctly, software is properly configured, etc.
1-2
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Locate error on the error
Source of error known
Troubleshoot
and correct
source of
error
table and determine the
characteristics and possible
causes of the error
Run Program
and continue
to monitor
Source of error unknown
Error cleared and robot
runs normally
Run Program
and continue
to monitor
Press the yellow
reset button on the
controller panel
Error will not clear or
machine is in a “locked” mode
Have any changes been
Error clears and robot
runs normally
made to system? New
internal parts, interface
components added or
removed, signal interface
agrees with program, etc.
Run Program
and continue
to monitor
Ensure the robot
system data, all
components, signals,
and programs are
compatible
Yes
No
Error or “locked”
condition cleared
Run Program
and continue
to monitor
Cycle the
controller power
OFF and ON
Error still present
Error or “locked”
condition cleared
Create
Reset
Run program
and continue
to monitor
backup information
files and initialize the
system
system settings not
set to defaults after
initialization
Continued on next page
Figure 1-1 Troubleshooting Process
August 9, 2005
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Continued from previous pg
Error still present
Remove the
1KA board from the
rack and allow RAM
memory to deplete
Reinstall
1KA board,
initialize the
system, zero
Error clears and robot
runs normally
Run program
and continue
to monitor
Begin electrical
troubleshooting and repair if
qualified; call service
technician for further
assistance
Figure 1-2 Troubleshooting Process (Continued)
1-4
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.2 PRELIMINARY TROUBLESHOOTING
Prior to following error code troubleshooting procedures, ensure preliminary trouble-
shooting steps are completed.
1. Ensure proper 460 VAC three-phase power is available at the input and output side
of the controller main disconnect (circuit breaker F1).
2. Ensure circuit breakers F2, F3, F4, and F5 are not tripped.
3. Ensure proper +5 VDC, +12 VDC, -12 VDC and +24 VDC are available from the
AVR power supply.
4. Observe the state of LEDs and refer to the appropriate section of the D Series
Controller Electrical Maintenance Manual for conditions indicated by the LEDs. If
these conditions are not normal, correct the cause of abnormal LED indications.
5. Check for loose connection at circuits boards and cable connections.
6. Ensure all circuit boards are properly seated in the card rack (where applicable).
7. Ensure the F1 and F2 fuses on the 1KP board are not open.
1.2.1 TROUBLESHOOTING COMMON FAILURES
This section describes some common failures, possible causes, and corrective actions.
1.2.1.1 Controller Power Cannot Be Set ON
1.2.1.2 Teach Pendant is Inoperable
1.2.1.3 Motor Power Cannot Be Set ON
1.2.1.4 Robot Does Not Move
August 9, 2005
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.2.1.1 CONTROLLER POWER CANNOT BE SET TO ON
This failure occurs when the controller does not power-up when the controller main
disconnect is set to ON.
Failure 1: When the controller main disconnect is set to ON, circuit breaker F1 is tripped
immediately.
Main causes include:
1. The AC power line is short-circuited in the controller, and circuit breaker F1 detects
overcurrent and is tripped.
2. Defective F1 circuit breaker.
⇒ Interrupt the 460 VAC to the main disconnect (circuit breaker F1) set the controller
main disconnect to ON. Using an ohm meter check for a short circuit between these
points:
R and S, S and T, T and R, R and FG, S and FG, T and FG (FG=frame ground)
If a short circuit is detected replace components as necessary (wiring, transformer
T1, circuit breaker F1, etc.).
Failure 2: When the main disconnect is set to ON, the control power lamp does not
illuminate (circuit breaker F1 does not trip).
This failure occurs when the controller does not activate properly because of an abnor-
mality in the primary power supplied to the controller or in the power supply circuit in the
controller.
Main causes include:
1. The primary power voltage supplied to the controller is not within specifications, the
primary power cable is disconnected or damaged, or the primary power is not
supplied.
2. Power is not supplied to the 1KQ/1NR board, or the 1KQ/1NR board is defective.
3. Power is not supplied to the AVR power supply.
4. Power is not supplied to the control power lamp due to a defective AVR power
supply, 1KX/1NR board, 1LS/1NS board or control power lamp.
5. Disconnected or short-circuited wiring in the controller.
1-6
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
⇒ Ensure primary power supply is within specifications. Ensure primary power supply
cable is properly connected and is not damaged.
⇒ Ensure connectors at the 1KQ/1NR board are properly installed and not damaged.
⇒ Ensure the 1KP board fuses F1 and F2 are not open.
⇒ Replace the 1KQ/1NR board.
⇒ Ensure the power supplied to the AVR power supply is within specifications. Ensure
the power connector at the AVR power supply is properly connected and not dam-
aged.
⇒ Ensure to output voltages from the AVR power supply are within specifications.
⇒ Ensure the control power lamp is properly installed and is not defective.
⇒ Repair or replace disconnected or short-circuited wiring in the controller.
August 9, 2005
1-7
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.2.1.2 TEACH PENDANT IS INOPERABLE
The teach pendant is in operable with the controller main disconnect set to ON and the
control power lamp is illuminated.
Failure 1: The control power lamp is illuminated and the teach pendant is inoperable
(the back light is not illuminated).
DC power is supplied to the controller, but power is not supplied to the teach pendant to
illuminate the display or back light.
Main causes include:
1. +12 VDC is not supplied to the teach pendant.
2. Defective LCD panel, circuit board, or other internal teach pendant components.
3. Disconnected or short-circuited teach pendant cable.
⇒ Ensure the teach pendant cable is properly connected to the controller.
⇒ Replace the teach pendant.
⇒ Replace the teach pendant cable.
Failure 2: The back light is illuminated, but the screen is not displayed.
When the teach pendant back light is illuminated this indicates power is supplied to the
teach pendant. If the teach pendant is operating normally the initial screen is displayed
regardless of the 1KA board condition.
Main causes include:
1. Defective LCD panel, circuit board, or other internal teach pendant components.
⇒ Replace the teach pendant.
Failure 3: The teach pendant screen is displayed and the back light is illuminated, but
key input and AS Language commands are not possible.
This condition occurs when key input and AS Language commands do not reach the
1KA board or data from the 1KA board does not reach the teach pendant.
Data is transmitted between the 1KA board and the teach pendant as shown in figure 1-
3.
1-8
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1KX/1NX Mother Board
Display Device
Input
Keys
1KA Main CPU Board
Teach Pendant
Figure 1-3 1KA/Teach Pendant Communication
Main causes include:
1. Interruption in data communication between the teach pendant and the 1KA board.
2. Defective LCD panel, circuit board, or other internal teach pendant components.
3. Defective 1KA or 1KX/1NX boards.
4. Disconnected or short-circuited teach pendant cable.
⇒ Ensure the teach pendant cable is properly connected to the controller.
⇒ Replace the teach pendant cable.
⇒ Replace the teach pendant.
⇒ Replace the 1KA or 1KX/1NX boards.
August 9, 2005
1-9
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.2.1.3 MOTOR POWER CANNOT BE ENABLED
This condition exists when motor power does not engage when the MOTOR POWER
switch is pressed.
Main causes include:
1. An error condition exists.
2. K1, K2, or K3 are not engaged due to a defective 1KQ/1NR board, MC unit, teach
pendant, software, eternal signals etc.
3. Emergency stop condition exists.
4. Defective power block.
5. Disconnected or short-circuited motor power supply harness.
6. Motor temperature or controller internal temperature exceeds limits
⇒ If the operation panel error lamp is illuminated or an error message is displayed on
the teach pendant LCD, take appropriate measures to release the error condition
according to the error message.
⇒ Check and repair any abnormalities in the motor power supply circuit.
⇒ Ensure all EMERGENCY STOP switches are released.
⇒ Replace the power block.
⇒ Replace the motor power supply harness.
⇒ Ensure motor temperature and controller internal temperature does not exceed limits.
1-10
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.2.1.4 ROBOT DOES NOT MOVE
This condition exists when the robot does not move when conditions are set for teach or
repeat mode.
Main causes include:
1. External hold condition exists.
2. An error condition exists.
3. Operation panel switches set incorrectly.
4. Motor brakes are not released.
5. If the check mode is selected, ensure an enabling device is engaged and the GO
(step forward) key is pressed.
6. Robot is waiting for input signals in repeat mode (cycle start, step forward, program
change, WX, JUMP, etc.)
⇒ Release external hold condition.
⇒ If the operation panel error lamp is illuminated or an error message is displayed on
the teach pendant LCD, take appropriate measures to release the error condition
according to the error message.
⇒ Ensure the operation panel switches are set correctly for robot operation.
⇒ Ensure proper brake voltage is available to the brake release circuit. Check and
repair poor connections, disconnected connectors, open wiring, short circuited wiring,
or any abnormalities in the brake circuits. Ensure the 1KP board, 1KQ/1NR board,
AVR power supply, MC unit, 1KQ/1NR board, servo motor, and controller internal
brake harnesses are in serviceable condition.
⇒ When check mode is selected, ensure an enabling device is engaged and the GO
(step forward) key is pressed.
⇒ In repeat mode, ensure input signals are received to release a wait condition.
! WARNING
The robot may move suddenly when a wait condition is
released. Do not approach the robot when it appears to
be stopped.
August 9, 2005
1-11
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.3 ERROR CODES
This unit provides information about the error codes that are displayed on the teach
pendant or other user interfaces that provide display screen information. The error
codes are listed in numerical order by prefix and code number with the message that is
displayed on the teach pendant. An expanded explanation of the message is provided
along with possible methods to clear or prevent the specific error. Troubleshooting
information is preceded by an ⇒ symbol.
Table 1-1 provides an explanation of the error code prefixes.
Table 1-1 Error Code Prefix Descriptions
Error Log Code
Description
Fatal error
Comment
D
Hardware, software, or peripheral device error.
When error is corrected control power must be
cycled OFF and ON.
E
P
Non-fatal error
Operation error
When error is corrected, press error reset.
Does not affect robot motion.
W
Mechanical/control warning May cause an error if not corrected.
Table 1-2 describes the controller state for each type of error.
Table 1-2 Controller Error State
Error Type
Error Lamp
OFF
1ON or OFF
Cycle Start Lamp
Motor Power
ON
1ON or OFF
1ON or OFF
OFF
P
W
E
ON
1ON or OFF
OFF
ON
D
ON
OFF
1Depending on the error content
1-12
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.3.1 ERROR DISPLAY
Error messages are displayed on the teach pendant LCD screen and/or a PC interfaced
with the controller using KRterm/KCWIN32 terminal software.
The teach pendant LCD screen displays operation errors (P errors) in the system mes-
sage area and other error messages are shown in a pop-up screen display (Figure 1-4).
Step
Program [Comment ]
Status
03-01-31 11:55
PC
JOINT
1 pcprg1
T
pg6
1
]
C
R
[
[
]
90%
Program aborted. No = 1
System Message Area
Error Pop-up Screen
R P S
Error
!
(E0100) 02-11-08(Fri) 16:33:20
Abnormal comment statement exists.
Reset
Close
JT 1
0.000
JT 2
0.000
JT 3
0.000
JT 4
JT 5
JT 6
0.000
0.000
0.000
Figure 1-4 Teach Pendant Error Screen Display
1.3.2 ERROR LIST
Refer to the following sections for errors and descriptions:
1.3.2.1 DXXXX Fatal Error Codes
1.3.2.2 EXXXX Non-Fatal Error Codes
1.3.2.3 PXXXX Operation Error Codes
1.3.2.4 WXXXX Mechanical/Control Warning Error Codes
August 9, 2005
1-13
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.3.2.1 DXXXX FATAL ERROR CODES
ERROR CODE D0001 CPU Error. (PC=XX)
The 1KA board CPU has stopped (detected by the AS software). This error is caused
by defective AS or servo software, defective hardware, or noise related malfunction.
PC Error Display Example:
Error (D0001) CPU error Code=1
Task (Pc01) Stop SIG=00070004 [FAULT (PARALLEL)] PC=*****
Indicates the place the error occurred
⇒ Refer to the error message displayed on a PC interfaced with the controller.
⇒ Cycle controller power OFF and ON. Do not initialize the controller. If a message for
initialization is displayed, select “NO”.
⇒ If the error does not reset when power is cycled, initialize the system and reload
program data.
⇒ Replace the 1KA board.
⇒ If the above steps do not correct the error, contact KRI customer service.
_____________________________________________________________________
ERROR CODE D0002
Main CPU BUS error. (PC=XX)
A 1KA board bus error occurs (in the VME bus line, detected by AS software); data
processing is not completed normally. This error is caused by defective AS software,
defective 1KA board, or noise related malfunction.
PC Error Display Example:
Error (D0002) CPU BUS error Code=1
Task (Pc01) Stop SIG=00070004 [NMI(VME BUS ERROR)] PC=*****
Indicates the place the error occurred
⇒ Refer to the error message displayed on a PC interfaced with the controller.
⇒ Cycle controller power OFF and ON. Do not initialize the controller. If a message for
initialization is displayed, select “NO”.
⇒ If the error does not reset when power is cycled, initialize the system and reload
program data.
⇒ Replace the 1KA board.
⇒ If the above steps do not correct the error, contact KRI customer service.
_____________________________________________________________________
1-14
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D0003
VME BUS error. (PC=XX)
This error occurs when the CPU does not receive a response from one of the I/O bus
devices within a specific time. This error is caused by defective AS software, defective
1KA board, or noise related malfunction.
PC Error Display Example:
Error (D0003) VME bus error Code=1
Task (Pc01) Stop SIG=00070004 [NMI(VME BUS ERROR)] PC=*****
bus-read=******** bus-write=*********
Indicates the place the error occurred
⇒ Refer to the error message displayed on a PC interfaced with the controller.
⇒ Cycle controller power OFF and ON. Do not initialize the controller. If a message for
initialization is displayed, select “NO”.
⇒ If the error does not reset when power is cycled, initialize the system and reload
program data.
⇒ Replace the 1KA board.
⇒ If the above steps do not correct the error, contact KRI customer service.
_____________________________________________________________________
ERROR CODE D0004
[ARM CONTROL BOARD] CPU error. (PC=XX)
The 1KB board CPU is stopped (detected by the AS software). This error is caused by
defective AS or servo software, defective hardware, or noise related malfunction.
PC Error Display Example:
Error (D0004) [ARM CONTROL BOARD] CPU error Code=1
Task (Pc01) Stop SIG=00070004 [FAULT (PARALLEL)] PC=*****
Indicates the place the error occurred
⇒ Refer to the error message displayed on a PC interfaced with the controller.
⇒ Cycle controller power OFF and ON. Do not initialize the controller. If a message for
initialization is displayed, select “NO”.
⇒ Ensure the correct 1KB board software is loaded into the 1KA board.
⇒ Replace the 1KB board.
⇒ If the above steps do not correct the error, contact KRI customer service.
_____________________________________________________________________
August 9, 2005
1-15
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D0005
[ARM CONTROL BOARD] CPU BUS error. (PC=XX)
On the 1KB board, a bus error occurs (in the VME bus line, detected by AS software);
data processing is not completed normally. This error is caused by defective AS soft-
ware, defective 1KB board, or noise related malfunction.
PC Error Display Example:
Error (D0005) [ARM CONTROL BOARD] CPU BUS error Code=1
Task (Pc01) Stop SIG=00070004 [NMI(VME BUS ERROR)] PC=*****
Indicates the place the error occurred
⇒ Refer to the error message displayed on a PC interfaced with the controller.
⇒ Cycle controller power OFF and ON. Do not initialize the controller. If a message for
initialization is displayed, select “NO”.
⇒ Ensure the correct 1KB board software is loaded into the 1KA board.
⇒ Replace the 1KB board.
⇒ If the above steps do not correct the error, contact KRI customer service.
_____________________________________________________________________
ERROR CODE D0900
Teach data is broken.
The program storage area of the system memory is damaged and is not linking data
correctly.
Main causes include:
1. Loss of memory battery back-up.
2. Noise related malfunction.
3. Defective 1KA board.
⇒ Set the 1KA board switch SW2-8 to ON and initialize the memory, do not use AUX
0805 or SYSINIT command. Reload the robot program data.
⇒ Check the memory backup battery. Replace if necessary (3.3 VDC or less). When
battery voltage drops to 3.3 VDC, or less, error W1010 is displayed.
⇒ Replace the 1KA board if the error recurs.
_____________________________________________________________________
1-16
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D0901
AS Flash memory sum check error.
A check sum error occurrs in AS software, in flash memory on the 1KA board, when the
controller is powered-up. The check sum data is created when the FCHK command is
executed and is recorded in flash memory during AS software download.
Main causes include:
1. When the AS software is downloaded, the FCHK command is not executed.
2. The addressing of the FCHK command is wrong.
3. The flash memory and 1KA board are defective.
4. The system data in the flash memory is corrupt.
⇒ Confirm the content of the command as_load.cmd file on the PC card. If error occurs
immediately after downloading the AS software, download AS software again. If error
continues after download, replace the 1KA board.
_____________________________________________________________________
ERROR CODE D0902
Servo flash memory sum check error.
A check sum error of the servo software in flash memory on the 1KA board occurrs
when the controller is powered-up. The check sum data is created when the FCHK
command is executed and is recorded in flash memory during software download.
Main causes include:
1. When the servo software is downloaded, the FCHK command is not executed.
2. The addressing of the FCHK command is wrong.
3. The flash memory and 1KA board are defective.
4. The system data in flash memory is corrupt.
⇒ If the error occurs immediately after servo software download, confirm the content of
sv_load.cmd on the PC card and download servo software again. If the error reoc-
curs, replace the 1KA board.
_____________________________________________________________________
ERROR CODE D0903
IP board memory error. (Code)
This error occurs when the flash ROM on the 1GS board is corrupt (check sum error).
Code 2: flash ROM SAM error.
Code 3: DPRAM write and read error.
Code 4: SRAM write and read error.
⇒ Replace the 1GS board.
_____________________________________________________________________
August 9, 2005
1-17
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D0904
Memory is locked due to AC_FAIL.
The memory is accessed during the controller shut down due to a power supply abnor-
mality (ACFAIL) (AVR +5 V, +12 V, -12 V, +24 V).
⇒ Cycle the controller power OFF and ON.
⇒ Check for proper AVR voltage supply (+5 V, +12 V, -12 V, +24 V) and related circuitry.
_____________________________________________________________________
ERROR CODE D1000
Read error of servo control software.
Main causes include:
1. Servo control software (armsc.mb) not found at controller power-up or software is
corrupt.
2. Defective 1KJ/1QJ board.
⇒ Download servo control software (armsc.mb).
⇒ Replace 1KJ/1QJ board.
_____________________________________________________________________
ERROR CODE D1001
Download error of servo control software.
Servo control software (armsc.mb) download failure at controller power-up.
Main causes include:
1. Incorrect servo control software.
2. Defective 1KJ/1QJ board.
2. Defective 1KA and or 1KB board.
⇒ Ensure the correct servo software is loaded into the 1KA board.
⇒ Replace the 1KJ/1QJ board.
⇒ Replace the 1KA and or 1KB board.
_____________________________________________________________________
1-18
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1002
Init. error of servo software.
Servo software (armsc.mb) initialization failure at controller power-up.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Incompatibility between the AS and servo software.
3. Defective 1KA and or 1KB board.
⇒ Reinstall servo software.
⇒ Check compatibility of AS and servo software and reinstall software as needed.
⇒ Replace the 1KA and or 1KB boards.
_____________________________________________________________________
ERROR CODE D1003
Init. error of servo control software.
Servo software (armsv.abs) initialization failure at controller power-up.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Incompatibility between the AS and servo software.
3. Defective 1KA and or 1KB board.
⇒ Reinstall servo software.
⇒ Check compatibility of AS and servo software and reinstall software as needed.
⇒ Replace the 1KA and or 1KB boards.
_____________________________________________________________________
August 9, 2005
1-19
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1004
[ARM CTRL BOARD] watch dog error of servo control
software.
The watch dog circuit on the 1KA board or 1KB board has detected a software problem.
This is caused by a defective 1KA main CPU board or 1KB servo CPU board or a prob-
lem with the servo software.
Interface
CPU
ELPD
1KX (Mother Board)
Watch Dog
Error Signal
Servo
Control
CPU
1KA (Main CPU Board)
Gate Array
1KB (Servo CPU Board)
⇒ Replace the AS or servo software.
⇒ Replace the 1KA or 1KB board.
_____________________________________________________________________
ERROR CODE D1005
Servo board command error. (xx)
Servo software returned an error code, other than a servo system error, to the AS soft-
ware after receiving an unrecognized command from the 1KA board.
Interface
CPU
ELPD
1KX (Mother Board)
Servo
Control
CPU
1KA (Main CPU Board)
Gate Array
1KB (Servo CPU Board)
Main causes include:
1. Corrupt servo or AS software.
2. Noise malfunction.
3. Defective 1KB servo board or 1KA main CPU board.
4. Versions of servo and AS software incompatible.
⇒ Install correct versions of servo and AS software.
⇒ Replace the 1KA or 1KB board.
_____________________________________________________________________
1-20
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1006
AMP power unit error.
General servo system error. This error indicates that a servo system error has occurred.
Refer to any other servo system errors which occurred at the same time.
When a servo error signal (SVER) is sent from the 1KB board (servo CPU board) to the
1KP board (power sequence board) motor power is shut down. The error notification is
sent to the AS software via the EPLD. The error information from the 1KB board is sent
through the command line and the corresponding error code(s) is/are displayed after
D1006.
1KP (Power Sequence Board)
Interface
CPU
ELPD
1KX (Mother Board)
Servo
Control
CPU
1KA (Main CPU Board)
Gate Array
1KB (Servo CPU Board)
⇒ Check the servo error codes that follow this error for additional information. Ensure
that the 1KP board and 1KB board are properly seated.
_____________________________________________________________________
August 9, 2005
1-21
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1007
Regenerative time over [XX].
This error occurs when current is sent to regenerative resistors for six or more consecu-
tive seconds.
When the robot decelerates, the motors enter the power generation state to absorb the
inertia energy from the arm. When the P-N power voltage exceeds the rated value (390
VDC), the current is split from the power block to the regenerative resistor. When the
voltage drops to a safe level (365 VDC) the resistor is removed from the circuit.
Motor power
Motor power circuit
Interface
CPU
P-N power
voltage
monitoring
circuit/
Regeneration
controlling
circuit
Motor power
(P-N power
voltage)
Drive circuit
1KC: IGBT
1KD: IGBT
Servo
CPU
1KL/1KR: FET
Regenerative
signal
Gate Array
1KB board
Regenerative
resistor
Power block
Controller
Main causes include:
1. Abrupt direction changes at high speed.
2. Burned out regenerative resistors in the power block.
3. Defective power block.
4. Defective servo board (1KB board).
5. Loose or disconnected harness between 1KX board (mother board) connector X211
or X212 and the 1KB board (servo CPU board) connector X501 or X502.
6. Defective/incorrect optional second regenerative resistance unit (when used).
⇒ Avoid abrupt high speed direction changes. Change accuracy, speed, add points.
⇒ Replace defective regenerative resistor.
⇒ Install/replace optional second regenerative resistance unit.
⇒ Replace defective 1KB board.
⇒ Replace defective power block.
⇒ Check connections described in item 5 and repair as necessary.
_____________________________________________________________________
1-22
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1008
P-N low voltage [XX].
The voltage between P-N supplied to the power block is 60 VDC or less at servo on.
! WARNING
Because motor power is not supplied, when low voltage
occurs, the arm will fall until the error is detected. As a
result, other errors may be generated (abnormal speed,
deviation error, etc.).
Primary power
Motor power
Main
MC unit
disconnect
(1KQ/1NQ board)
K3 STATUS
Interface
CPU
P-N power
voltage
monitoring
circuit
P-N power low
voltage error
Servo
CPU
EPLD
Gate Array
1KB board
1KP board
Power block
Main causes include:
1. Motor power circuit connector detached or loose.
2. Three phase (U, V, W) control power circuit breaker set to OFF.
3. Defective 1KB/1KP/1KQ/1NQ boards.
4. Defective power block.
5. Defective MC unit or harness.
⇒ Ensure the motor power circuit connector is properly attached.
⇒ Ensure control power circuit breaker is set to ON.
⇒ Replace the 1KB/1KP/1KQ /1NQ boards.
⇒ Replace the power block.
⇒ Replace the MC unit or harness.
_____________________________________________________________________
August 9, 2005
1-23
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1009
P-N- high voltage [XX].
The voltage between P-N supplied to the power block exceeded 410 VDC.
Primary power
Main
MC unit
disconnect
(1KQ/1NQ board)
Motor power
Interface
CPU
Additional
regenerative
resistor
Regenerative
resistor
P-N power
voltage
monitoring
circuit
P-N power high
voltage error
Servo
CPU
Thermal
(140° C)
Thermal
(140° C)
Gate Array
1KB board
Power block
Additional regenerative
resistor (option)
Main causes include:
1. High inertia loads due to excessive tool weight or incorrect program data.
2. Defective regenerative resistance control circuit, overheat failure of regenerative
resistance unit, defective voltage monitoring circuit, or defective power block.
3. Defective servo board (1KB board) or harness.
4. Defective additional regenerative resistance unit.
⇒ Reteach program steps to eliminate sudden high speed direction changes (dynamic
shock).
⇒ Replace the regenerative unit.
⇒ Replace the 1KB board, power block or harness.
⇒ Replace the additional regenerative resistor unit.
_____________________________________________________________________
1-24
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1010
Regenerative resistor over-heat [XX].
The thermal switch for the power block regenerative resistor unit, or the optional regen-
erative resistor unit reached 140° C (284°F), or the heat sink thermal switch reached
90° C (194°F), or the controller cabinet thermal switch reached 70° C (158° F). The
thermal switches are wired in series and the AS software cannot distinguish which
thermal switch is activated. For D7X controller, if the heat exchange fan is inoperative
(X207 disconnected) this error is generated.
Primary power
Main
MC unit
disconnect
(1KQ/1NQ board)
Motor power
Interface
CPU
Additional
regenerative
resistor
Regenerative
resistor
P-N power
voltage
monitoring
circuit
P-N power high
voltage error
Servo
CPU
Thermal
(140° C)
Thermal
(140° C)
Gate Array
1KB board
Power block
Additional regenerative
resistor (option)
Main causes include:
1. High inertia loads due to excessive tool weight or incorrect program data.
2. Defective cooling fans.
3. Insufficient clearance for air circulation.
4. High ambient controller temperature.
5. Defective power block.
6. Disconnected or defective harness between the 1KC/1KD board and the additional
regenerative resistor unit.
7. Defective regenerative resistor unit.
8. Defective additional regenerative resistor unit.
9. Defective 1KB board.
10. Disconnected or defective harness between X211 or X212 on the 1KX/1NX board
and X501 or X502 on the power block.
August 9, 2005
1-25
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
⇒ Reteach program steps to eliminate sudden high speed direction changes (dynamic
shock).
⇒ Ensure cooling fans are in proper working condition.
⇒ Reduce controller ambient temperature.
⇒ Replace defective thermal switch(es).
⇒ Repair or replace disconnected or defective harness(es).
⇒ Replace the regenerative unit.
⇒ Replace the 1KB board, power block or harness.
⇒ Replace the additional regenerative resistor unit.
⇒ Connect or repair D7X power supply connection for heat exchange fan (X207).
_____________________________________________________________________
ERROR CODE D1011
AS or servo software is not compatible with the robot
model.
This error occurs when the servo software does not match the robot specifications.
⇒ Load the correct AS and servo software.
_____________________________________________________________________
ERROR CODE D1012
Servo type mismatch. Check the settings.
Servo type set for the robot and servo software do not match.
⇒ Change the robot servo type setting.
⇒ Install servo software that matches the robot setting.
_____________________________________________________________________
1-26
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1013
P-N capacitor is not discharged.
This error occurs when motor power is OFF for a period of time and the P-N power
voltage does not decrease to 60 VDC or less.
Primary power
Motor power
Main
MC unit
disconnect
(1KQ/1NQ board)
K3 STATUS
Interface
CPU
P-N power
voltage
monitoring
circuit
P-N capacitor
discharge error
Servo
CPU
EPLD
Gate Array
1KB board
1KP board
Power block
Main causes include:
1. Defective 1KB/1KP/1KQ/1NQ boards.
2. Defective power block.
3. Defective MC unit or harness between the MC unit and the power block.
⇒ Replace the 1KB/1KP/1KQ/1NQ boards.
⇒ Replace the power block.
⇒ Replace the MC unit or harness between the MC unit and the power block.
_____________________________________________________________________
ERROR CODE D1014
Servo system error. (Code=XX)
An unrecognized error occurred in the 1KB board.
⇒ Contact KRI customer service (include operating conditions/settings at the time the
error occurred).
_____________________________________________________________________
ERROR CODE D1015
The servo data file does not exist.
This error occurs when the servo data file is not found.
⇒ Contact KRI customer service (include operating conditions/settings at the time the
error occurred).
_____________________________________________________________________
August 9, 2005
1-27
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1016
Data applicable to the robot model not in servo servo data
file.
This error occurs when the installed robot model file is not found in the servo data file.
⇒ Contact KRI customer service (include operating conditions/settings at the time the
error occurred).
_____________________________________________________________________
ERROR CODE D1017
Error of download of servo data.
Servo data could not be downloaded from the servo software at controller power-up.
⇒ Ensure the correct servo software is installed.
⇒ Ensure the 1KA and 1KB boards are properly installed.
_____________________________________________________________________
1-28
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1500
Encoder misread error JtXX.
Immediately after control power on, steady encoder data is not able to be read. This
error is caused by a disconnected encoder signal line or a short circuit, or a defect in the
main body of the encoder.
Encoder
Encoder
Encoder I/F
1KB board
Battery
Power circuit
1FG/1HG board
Encoder power supply +12 V
Controller
Robot
Main causes include:
1. Defective encoder or encoder harness.
2. Defective servo weld gun encoder (detected at controller power-up/power-down with
gun connected.
3. Servo weld gun is not connected.
4. Defective 1KB board.
5. Defective 1FG/1HG board.
⇒ Check for disconnection or short circuit in encoder signal line.
⇒ Replace the encoder or encoder harness.
⇒ Replace the 1KB servo board.
⇒ Replace the 1FG/1HG board.
⇒ Release the servo weld gun axis in teach mode and cycle controller power OFF and
ON.
_____________________________________________________________________
August 9, 2005
1-29
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1501
Defective gun changer connection or encoder comm. error.
This error occurs when the servo weld gun is connected and encoder data is not read
normally within the specified time.
Main causes include:
1. Improper connection at the tool changer.
2. Defective encoder or encoder communication line.
⇒ Check tool changer connection and repair as necessary.
⇒ Check encoder and encoder harness and replace as necessary.
_____________________________________________________________________
ERROR CODE D1502
Amp over current JtXX.
The feedback current from a current sensor in the power block exceeded 150% of the
maximum instantaneous motor current rating.
HIC
(Over current
detection)
1GM board
I/V
converter
Over current
error signal
Current
feedback
Gate
Array
1KB Board
PWM
Current
sensor
U, V, W
earth
Motors
Robot
IPM
Power block
Controller
Main causes include:
1. Short in the U, V, W from the power block to motor and ground wire.
2. Defective motor.
3. Defective power block.
4. Defective 1KB servo board, harness, etc.
⇒ Check the connection for the U, V, W and ground line to the power block. Replace the
separation harness if necessary.
⇒ Replace the motor, 1KB board, power block, or harness.
_____________________________________________________________________
1-30
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1503
Current detector type (XX) mismatch!
When the control power supply is turned ON, the ID code data of the 1GM (1KV) board
and the AS software installed on the 1KB board do not correspond. The unit name of
the servo board displayed at (XX) in the error message corresponds to the CH column
in the table below.
Relay to Power Sequence
CH
A
To Communication
First 1KB PC Board A Unit
First 1KB PC Board B Unit
First 1KB PC Board C Unit
or
Board (1KP PC Board)
Master
Master
Slave
B
C
Second 1KB PC Board A Unit
or
One Axis Amplifier
Second 1KB PC Board B Unit
or
D
Slave
One Axis Amplifier
Main causes include:
1. 1GM (1KV) board is not suitable for the AS software (robot model).
2. The AS software does not correspond to the 1GM (1KV) board.
⇒ Ensure the correct AS software is loaded.
⇒ Replace the 1GM (1KV) board.
_____________________________________________________________________
August 9, 2005
1-31
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1504
Abn. curr. feedback Jt XX. (Amp fail, pwr harness discon-
nect).
This error occurs if the current feedback value is near 0 from the time the servo is turned
ON until the brake is released, even if the commanded current value meets or exceeds
the expected current.
1GM board
Servo CPU
I/V
converter
Current
feedback
1KB Board
Current
sensor
U, V, W
earth
Motors
Robot
IPM
Power block
Controller
Main causes:
1. Motor power line U, V, and/or W phase are disconnected.
2. Improper power harness line connection.
3. Defective power block
⇒ Check the power line wiring and repair or replace as necessary.
⇒ Replace the power block.
_____________________________________________________________________
1-32
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1505
Motor harness disconnected or over heat. (XX)
Motor thermal circuit is open due to motor overheat or harness problem. Not all robot
models utilize thermal switches in the motors. Some robot models may have multiple
thermal switches connected in series (see diagram below). The FS03/06/10/20 robot
models have the thermal switch mounted near JT1 motor. The FS03 model is calibrated
to 55° C and FS06/10/20 models are calibrated to 65° C
Upper arm
Thermal switch
Rotor trunk
Interface
CPU
Thermal line
(TH)
Photo coupler
Thermal switch
Servo
CPU
Robot
Gate Array
1KB board
1KQ/1NR board
Controller
Main causes include:
1. Disconnected thermal line.
2. Defective connection in the separation harness.
3. Defective 1KB servo board.
4. Defective 1KQ/1NR board.
5. When the motor thermal switch is used:
–The robot rated weight capacity is exceeded.
–The ambient temperature exceeds limits for use.
–Excessive execution of abrupt high speed direction changes.
–Defective controller cooling fan or cooling air purge system.
–Servo system holding the robot arm in high load position for extended periods.
–Defective thermal switch.
⇒ When the thermal switch opens, error cannot be reset until cooling is complete.
⇒ Confirm continuity of thermal line.
⇒ Replace the harness or the 1KB servo board as necessary.
⇒ Replace the 1KQ/1NR board.
⇒ Use the auto servo off function, AUX 0808, to prevent the servo system holding a
high load arm position for extended periods.
_____________________________________________________________________
August 9, 2005
1-33
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1506
Power module error JtXX.
An error signal from the IPM module in the power block is detected by the 1KB board.
Robot
Motor
Interface
CPU
PWM signal
Servo
CPU
IPM error signal
IPM
HIC
Gate Array
1KB board
Power block
Controller
Main causes include:
1. U, V, and W phase short-circuited or short-circuited to ground wire.
2. Payload weight exceeds rating.
3. Defective cooling fan in the power block.
4. Ambient temperature above normal operating limits.
5. Constant execution of abrupt high speed direction changes.
6. Defective 1KB board.
7. Disconnected or defective harness between the 1KB board and the power block.
8. Disconnection or poor connection in the thermal line at the separate harness and/or
controller harness.
9. Defective thermal switch in the controller or servo motors (if used).
10. Defective power block.
⇒ Check and repair cause of U, V, and W phase short-circuited or short-circuited to
ground wire.
⇒ Ensure payload does not exceed rating.
⇒ Reduce ambient temperature.
⇒ Ensure cooling fans are in proper working condition.
⇒ Correct abrupt high speed direction changes in the robot program.
⇒ Replace the 1KB board.
⇒ Repair or replace the harness between the 1KB board and the power block.
⇒ Check the thermal line in the separate harness and controller harness, and repair or
replace as necessary.
⇒ Replace the power block.
_____________________________________________________________________
1-34
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1507
AC primary power OFF.
This error occurs when there is an instantaneous decrease in the primary power to the
AVR for control power supply (130–145 VAC or less for 20–30 msec).
Control
power
210 VAC
Circuit
breaker
Main
disconnect
Primary
power
AVR for
control power
F1
T1
Transformer
F3
REMOTE
AC error
signal
1KQ/1NQ board
AVR
output
cut
EPLD
Mother Board
Local
bus
1KP board
1KB board
1KX board
Main causes include:
1. The primary power is below the specified rating, or an instantaneous power decrease
occurred.
2. The non-fuseable breaker (NFB) F1 for the control power supply is turned OFF or
tripped due to a short-circuit.
3. An instantaneous decrease in the 210 VAC supply to AVR for the control power
supply.
4. Circuit breaker F3 is OFF or tripped due to a short circuit.
5. Defective AVR.
6. Defect in the primary power supply.
7. Defective 1KP board.
8. Defective 1KQ/1NQ board.
⇒ It is normal for this error to occur when NFB F1 is set OFF and back ON.
⇒ Check power supply circuit through NFB F1 and repair as necessary.
⇒ Check power supply circuit to the AVR through the circuit breaker F3 and repair as
necessary.
⇒ Confirm that primary power is supplied according to specifications.
⇒ Replace the 1KP board.
⇒ Replace the 1KQ/1NQ board.
⇒ Replace the AVR.
_____________________________________________________________________
August 9, 2005
1-35
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1508
24VDC power source is too low.
24 VDC to the power sequence board has dropped to +21.6 VDC or less.
Control
power
210 VAC
Circuit
breaker
Main
disconnect
Primary
power
AVR for
control power
F1
T1
Transformer
F3
1KQ/1NQ board
24 VDC
monitor
EPLD
DC error
signal
Mother Board
Local
bus
1KP board
1KB board
1KX board
Main causes include:
1. Defective AVR for control power supply.
2. Defective 1KP board.
3. Defective 1KQ/1NQ board.
4. Short circuit in the motor power on circuitry, the EMERGENCY STOP switch, or axis
restriction limit switch circuits.
5. Short in machine valve and sensor circuits.
⇒ Check the power supply, machine valve, and the sensor circuits for short circuits.
⇒ Ensure the 24 VDC load does not exceed the power supply capacity.
⇒ Check the AVR, the 1KP power sequence board, and the 1KQ/1NQ relay board and
replace as necessary.
_____________________________________________________________________
1-36
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1509
Primary power source is too high.
Voltage level of the AVR for the control power supply is too high (267-277 VAC or more
for 1-2 sec.).
Control
power
210 VAC
Circuit
breaker
Main
disconnect
Primary
power
AVR for
control power
F1
T1
Transformer
F3
REMOTE
AC error
signal
1KQ/1NQ board
AVR
output
cut
EPLD
Mother Board
Local
bus
1KP board
1KX board
Main causes include:
1. Primary power exceeds the specified rating.
2. Defective AVR.
3. Defective 1KP power sequence board.
4. Defective 1KQ/1NQ relay board.
5. Power supply circuit problem.
⇒ Ensure the power supply to the controller is within ratings.
⇒ Check power supply circuit to the AVR.
⇒ Confirm the supply power is within specifications.
⇒ Replace the 1KP board.
⇒ Replace the 1KQ/1NQ board.
⇒ Replace the AVR.
_____________________________________________________________________
August 9, 2005
1-37
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1510
Primary power source is too low.
Voltage level of the AVR primary power supply is too low (150-158 VAC or less for 1-2
sec.).
Control
power
210 VAC
Circuit
breaker
Main
disconnect
Primary
power
AVR for
control power
F1
T1
Transformer
F3
AC error
signal
1KQ/1NQ board
EPLD
Mother Board
Local
bus
1KP board
1KB board
1KX board
Main causes include:
1. Drop in the primary power supply voltage.
2. Defective AVR.
3. Defective NFB F1.
4. Defective 1KP power sequence board.
5. Defective 1KQ/1NQ relay board.
6. Power supply circuit problem.
⇒ Verify the power supply to the controller is within ratings.
⇒ Check the AVR and NFB F1 and replace as necessary.
⇒ Confirm supply power is within specifications.
⇒ Replace the 1KP board.
⇒ Replace the 1KQ/1NQ board.
_____________________________________________________________________
1-38
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1511
+12VDC or -12VDC is abnormal.
+/-12 VDC supplied to the 1KA board is out of specifications.
+12 VDC: +10.75 VDC or less.
-12 VDC: -10.4 VDC or more.
Main causes include:
1. Defective AVR.
2. Defective 1KA, 1KB, or 1KP board.
3. Power supply contacts in the motherboard are damaged.
5. Defective power block.
6. Defective 1FG/1HG board.
7. Short in the harness between the servo unit and the 1FG board.
8. Short in the optional circuit boards, i.e., vision, etc.
9. Insufficient DC power supply capacity to support optional boards.
⇒ Adjust the AVR output voltage.
⇒ Replace the AVR and each board for the control power supply.
⇒ Check for short circuits in the operation panel and separation harness and replace as
necessary.
_____________________________________________________________________
August 9, 2005
1-39
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1512
Brake line error for JtXX.
This error occurs when the 1KB board detects an error signal sent from the brake re-
lease control MOSFET on the 1KQ/1NR board.
Motor
Robot
Controller
1KP board
Brake power supply D7X
+24 VDC
Brake power supply D3X
Transformer Circuit breaker
Safety circuit
Brake power supply error signal
Voltage
monitoring
Brake release signal
Brake line error signal
MOSFET
1KB board
1KQ/1NR board
Brake line errors are not detected during motor power OFF. Brake line disconnection is
not detected during automatic operation. Brake line error detection timing is shown in
the diagram below.
ON
Motor power
START
Servo control
RELEASE
Brake release
Disconnection
detected
Short-circuit
detected
Main causes include:
1. Disconnection/short-circuit/ground fault/poor connection at the brake line axis motor
harness.
2. Defective connection for the brake power line.
3. Defective connection or harness between the 1KB and 1KQ/1NR boards.
4. Defective connection or harness between the 1KB and 1KX/1NX boards.
5. Defective connection or harness between the 1NR and 1NX boards.
6. Incorrect 1KP board safety circuit setting.
7. Defective 1KB or 1KQ/1NR board.
⇒ Check for disconnection or short-circuit in the motor harness, and repair or replace as
1-40
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
necessary.
⇒ Check and repair brake power line and connections as necessary.
⇒ Check and repair connections between 1KB and 1KQ/1NR, 1KB and 1KX/1NX, and
1NR and 1NX as necessary.
⇒ Ensure the 1KB board is properly seated in the card rack.
⇒ Ensure the 1KP board safety circuit setting is correct.
⇒ Replace the 1KB and or the 1KQ/1NR.
_____________________________________________________________________
ERROR CODE D1513
Brake power is abnormal. (XX)
This error occurs when the 1KB board detects an error signal sent from the brake power
supply, voltage monitoring circuit, on the 1KQ/1NR board.
Motor
Robot
Controller
1KP board
Brake power supply D7X
+24 VDC
Brake power supply D3X
Transformer Circuit breaker
Safety circuit
Brake power supply error signal
Voltage
monitoring
Brake release signal
Brake line error signal
MOSFET
1KB board
1KQ/1NR board
Main causes include:
1. Defective transformer winding for brake power supply.
2. Short or open in wiring from transformer to brake power supply circuit.
3. Disconnected or defective harness between the 1KB board and the 1KQ/1NR board.
4. 1KB board not properly seated in the 1KX/1NX board.
5. 1NR board not properly seated in the 1NX board.
6. Defective circuit breaker F4 or F4 tripped.
7. Defective MC unit (1KQ board).
8. Defective 1NR board.
⇒ Check transformer winding and wiring and repair or replace as necessary.
⇒ Repair or replace harness between the 1KB and 1KQ/1NR board.
⇒ Ensure the 1NR and or the 1KB boards are properly seated in the 1KX/1NX board.
⇒ Replace MC unit.
⇒ Reset or replace circuit protector F4 as necessary.
⇒ Replace the 1KB and or 1KQ/1NR boards as necessary.
_____________________________________________________________________
August 9, 2005
1-41
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1514
I/O 24V fuse is open.
Fuse F2 on the 1KP board is open.
Main causes include:
1. Solenoid valve or diode polarity reversed.
2. Current load on the 24 VDC I/O circuit exceeds rating.
3. Short-circuit or ground fault in the 24 VDC I/O harness.
4. Defective 1KP board.
⇒ Check components for proper polarity and repair as necessary.
⇒ Ensure the load on the 24 VDC I/O circuit is within rating.
⇒ Check the I/O harness and replace as necessary.
⇒ Replace fuse F2 on the 1KP board (after cheching for short-circuit).
⇒ If the above steps do not correct the problem, replace the 1KP board.
_____________________________________________________________________
ERROR CODE D1515
Mismatch in setting of safety circuit as single/double.
Main causes include:
1. Safety circuit setting between the software and hardware do not match.
2. Defective 1KP board.
⇒ Set SW-2 on the 1KP board to ON for a double circuit or OFF for a single circuit.
⇒ In AUX 2021-2 set [2 Line] ON or [1 Line] OFF.
⇒ Replace 1KP board.
_____________________________________________________________________
ERROR CODE D1516
Mismatch betw hard/software settings for HOLD backup
time.
Main causes include:
1. The setting that specifies a two second delay before motor power is set OFF when
the RUN/HOLD switch is switched from RUN to HOLD, is not matched between the
software and hardware.
2. Defective 1KP board.
⇒ Set SW-1 on the 1KP board to ON for two second delay or OFF no delay.
⇒ In AUX 2021-2 set the delay parameter to [standard] (delay) or [Off] (no delay).
⇒ Replace 1KP board.
_____________________________________________________________________
1-42
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1517
Blown fuse on safety circuit emergency line.
Fuse F1 on the 1KP board is open.
Main causes include:
1. Incorrect wiring in the emergency line (wiring harness, emergency stop, safety fence,
external trigger, teach pendant, limit switches).
2. Short-circuit in the emergency line (wiring harness, emergency stop, safety fence,
external trigger, teach pendant, limit switches).
3. Defective 1KP board.
⇒ Check wiring and components in the safety circuit emergency line and repair/replace
as necessary.
⇒ Replace 1KP board.
⇒ Ensure the controller power is set OFF, when wiring safety circuits. The fuse F1 will
blow if wiring is shorted.
_____________________________________________________________________
ERROR CODE D1518
Mismatch in the Emer. Stop condition safety circuit.
Main causes include:
1. When the system is set for double safety circuits, and the circuits at the operation
panel, teach pendant, and/or the external emergency stop switch are wired as single
circuits.
2. Disconnection or ground fault in the emergency stop circuit.
3. Defective 1KP board.
⇒ With the E-STOP switch(es) engaged, check wiring harness and switches in the
circuit and repair or replace as necessary.
⇒ Ensure all contacts in the external emergency stop circuit are wired correctly (double
circuits).
⇒ If the above steps do not correct the problem, replace the 1KP board.
_____________________________________________________________________
August 9, 2005
1-43
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1519
Mismatch of the safety circuit LS condition.
In a double safety circuit system, conditions set for contacts in the limit switch (LS)
circuit do not match.
Main causes include:
1. Defective harness connection or harness (short-circuit or ground fault in harness).
2. Defective LS override switch.
3. Defective 1KP board
⇒ Replace the controller/separate/machine harness(es).
⇒ Replace the LS override switch.
⇒ Replace the 1KP board.
_____________________________________________________________________
ERROR CODE D1520
Mismatch of the safety circuit TEACH/REPEAT condition.
Main causes include:
1. TEACH/REPEAT switch setting and relay conditions for switching teach/repeat modes
do not match.
2. Contact condition at the TEACH/REPEAT switch does not match between the first
and second safety circuits.
3. Defective 1KP board.
⇒ Check the TEACH/REPEAT switch and relays (RY5 and RY6 on the 1KP board), and
replace as necessary.
⇒ Replace the 1KP board.
_____________________________________________________________________
ERROR CODE D1521
Mismatch in safety circuit safety-fence condition.
In a double safety circuit system, conditions set for contact at the safety fence circuit do
not match.
Main causes include:
1. Incorrect circuit or wiring for safety fence circuit (single circuit wired).
2. Disconnection or ground fault in the safety fence circuit wiring.
3. Defective safety fence switch.
4. Defective 1KP board.
⇒ Inspect contact points at the safety fence circuit and repair or replace as necessary.
⇒ Replace the 1KP board.
_____________________________________________________________________
1-44
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1522
Mismatch in cond. of safety circuit enabling device.
In a double safety circuit system, conditions set for contacts at the TRIGGER switch
circuit do not match.
NOTE
If the trigger switch is not pressed firmly, only one con-
tact may engage resulting in this error. The trigger
switch has three positions and pressing too firmly may
disengage the trigger circuit.
⇒ Replace the teach pendant, teach pendant harness or controller harness to the teach
pendant connector.
⇒ Replace the 1KP board.
_____________________________________________________________________
ERROR CODE D1523
Mismatch in cond. of safety circuit enabling device.
In a double safety circuit system, conditions set for contacts at the EXTERNAL TRIG-
GER switch circuit do not match.
⇒ Inspect contacts on the EXT.TRIGGER switch and replace as necessary.
⇒ Check for disconnection or short-circuit in external trigger wiring and repair as neces-
sary.
⇒ Replace the 1KP board.
_____________________________________________________________________
ERROR CODE D1524
Incorrect operation of the safety relay.
Safety relay on the 1KQ board did not operate correctly.
Main causes include:
1. Defective controller harness.
2. Defective 1KQ board
3. Defective MC unit.
4. Defective 1KP board.
⇒ Replace controller harness.
⇒ Replace the 1KQ board.
⇒ Replace the MC unit.
⇒ Replace the 1KP board.
_____________________________________________________________________
August 9, 2005
1-45
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1525
Incorrect operation of MC (K1).
Main causes include:
1. Defective controller harness.
2. Defective magnetic contactor K1.
3. Defective MC unit (1KQ/1NQ board).
4. Defective 1KP board.
⇒ Replace controller harness.
⇒ Replace magnetic contactor K1.
⇒ Replace MC unit (1KQ/1NQ board).
⇒ Replace 1KP board.
_____________________________________________________________________
ERROR CODE D1526
Incorrect operation of MC (K2).
Main causes include:
1. Defective controller harness.
2. Defective magnetic contactor K2.
3. Defective MC unit (1KQ/1NQ board).
4. Defective 1KP board.
⇒ Replace controller harness.
⇒ Replace magnetic contactor K2.
⇒ Replace MC unit (1KQ/1NQ board).
⇒ Replace 1KP board.
_____________________________________________________________________
ERROR CODE D1527
Incorrect operation of MC (K3).
Main causes include:
1. Defective controller harness.
2. Defective magnetic contactor K3.
3. Defective MC unit (1KQ/1NQ board).
4. Defective 1KP board.
⇒ Replace controller harness.
⇒ Replace magnetic contactor K3.
⇒ Replace MC unit (1KQ/1NQ board).
⇒ Replace 1KP board.
_____________________________________________________________________
1-46
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1528
Controller temperature is out of range.
Temperature inside the controller exceeds specification.
Main causes include:
1. Defective cooling fan(s). For D7X controller, defective heat exchange fan on the left
side of the controller.
2. Ambient temperature above specified rating.
3. Defective 1KP board.
⇒ Inspect cooling fans for proper operation and replace fans and/or fan harness(es) as
necessary.
⇒ Ensure air inlet filter is not restricted.
⇒ Lower ambient temperature within specifications.
⇒ Replace the 1KP board.
_____________________________________________________________________
ERROR CODE D1529
Signal harness is disconnected or encoder power error.
This error is caused when a communication error occurs for all axes.
Main causes include:
1. Separate harness disconnected or poor connection.
2. Abnormality in encoder power supply.
3. Low battery voltage on the encoder battery board (1FG/1HG).
4. Defective encoder battery board (1FG/1HG).
⇒ Ensure proper connections at the separate harness.
⇒ Ensure proper encoder power is supplied.
⇒ Replace batteries on the encoder battery board (1FG/1HG).
⇒ Replace the encoder battery board (1FG/1HG).
_____________________________________________________________________
ERROR CODE D1530
Abnormal current limit of JtXX.
Main causes include:
1. Ground fault in the motor power line U/V/W.
2. Unavailable program data.
⇒ Check motor power line and replace as necessary.
⇒ Modify program data.
_____________________________________________________________________
August 9, 2005
1-47
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D1531
Heat sink on power block overheated.
Main causes include:
1. Temperature inside the controller above specification because of air inlet or outlet
blockage.
2. Defective cooling fan.
3. Defective power block.
⇒ Ensure air inlet and outlet ports are clear.
⇒ Ensure cooling fans are in proper working order.
⇒ Replace the power block.
_____________________________________________________________________
ERROR CODE D2000
No response from Comm. board for laser sensor.
Laser sensor communication board program stopped.
⇒ Set robot controller and laser sensor power OFF. Set laser sensor power ON then set
robot controller power ON.
_____________________________________________________________________
ERROR CODE D2001
RI/O or C-NET board initialize error.
Initial data processing between the 1KA and 1FS/1HS boards is not correctly completed
at controller power-up.
Main causes include:
1. Defective 1KA board.
2. Defective 1FS/1HS board.
3. Noise related malfunction.
⇒ Ensure the 1KA and 1FS/1HS boards are properly seated into the 1KX/1NX board.
⇒ Ensure harnesses are properly connected at the 1KA and 1FS/1HS boards.
⇒ Check for noise malfunction and shield integrity.
⇒ Replace the 1KA board.
⇒ Replace the 1FS/1HS board.
_____________________________________________________________________
1-48
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2002
No response from the arm ID board.
Main causes include.
1. Defective 1KB board.
2. Defective 1KP board.
3. Defective 1GV arm ID board.
4. Defective harness.
5. Noise related malfunction.
⇒ Replace 1KB board.
⇒ Replace 1KP board.
⇒ Replace 1GV board.
⇒ Replace harness.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE D2003
No data in the arm ID board.
This error occurs when data is not present in the arm ID board (1GV) memory. This
error cannot be reset.
⇒ Execute the ZROBOT.ZZERO instruction and transfer the data to the arm ID board
(1GV).
⇒ Replace the arm ID board (1GV).
_____________________________________________________________________
ERROR CODE D2004
Mismatch data in the arm ID board.
This error occurs when robot data, other than the serial number, is different between the
arm ID board (1GV) and in the processor board (1KA). This error cannot be reset.
⇒ Robot data in the controller 1KA board and robot data in the arm ID 1GV board do
not match, confirm correct data is used.
⇒ Execute the ZBLTARM_ALLSET instruction and transfer the data from the controller
1KA board to the arm ID 1GV board.
_____________________________________________________________________
ERROR CODE D2005
CC-LINK software version mismatch.
Software versions installed in the 1HS board and AS software are incompatible.
⇒ Check 1HS board and AS software versions and reload software as necessary.
_____________________________________________________________________
August 9, 2005
1-49
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2006
Communication board to explosion-proof teach pendant
watch-dog error.
This error occurs when the CPU on the communication board (1GS board) for the explo-
sion-proof teach pendant is suspended.
Main causes include:
1. Defective communication board (1GS board).
2. Defective main CPU board (1KA board).
⇒ Replace defective 1GS board.
⇒ Replace defective 1KA board.
_____________________________________________________________________
ERROR CODE D2007
No response from the built-in sequence board.
This error occurs when the built-in PLC is in an error condition or the program mode.
⇒ Cycle the controller power OFF and ON after the cause of the built-in PLC error is
corrected.
⇒ Set the built-in PLC to the operating mode.
_____________________________________________________________________
ERROR CODE D2008
Arm ID I/F board error. (code XX).
This error occurs when a communication error exists between the arm ID board inter-
face board (1KP) and the arm ID board (1GV) (abnormal ROM, RAM, DPRAM, etc.).
⇒ Replace the arm ID board (1GV).
⇒ Replace the arm ID interface board (1KP).
⇒ Check and repair or replace harnesses and connections as necessary.
_____________________________________________________________________
ERROR CODE D2010
Sync. error between user I/F and arm control board.
1KA and 1KB board synchronization failed for 1 second or more.
⇒ Replace 1KA board.
⇒ Replace 1KB board.
_____________________________________________________________________
1-50
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2011
Parameter download error between user I/F & arm ctrl
boards.
1KA and 1KB boards parameter exchange cannot be downloaded.
⇒ Replace the 1KA board.
⇒ Replace the 1KB board.
_____________________________________________________________________
ERROR CODE D2012
SOFT ABSORBER error. Turn OFF & ON the control
power.
(Software absorber function)
Main causes include:
1. Abnormality during soft absorber sequence.
2. 1KB board upload/download is requested, but not executed.
⇒ Cycle controller power OFF and ON.
⇒ Replace the 1KB board.
⇒ If the error recurs, contact KRI Customer Service.
_____________________________________________________________________
ERROR CODE D2013
CHANGE GAIN Error. Turn OFF & ON the control power.
(Change gain function)
Main causes include:
1. Abnormality during change gain sequence.
2. 1KB board upload/download is requested, but not executed.
⇒ Cycle the controller power OFF and ON.
_____________________________________________________________________
ERROR CODE D2014
Robot network initialize error.
This error occurs when initialization of the Ethernet board is not successful during
power-up.
Main causes include:
1. 1KA board components do not correspond to Ethernet option.
2. Ethernet MAC address is not set.
3. Defective 1KA board.
⇒ Install the appropriate 1KA board and optional 1KN Ethernet board and set the MAC
address.
_____________________________________________________________________
August 9, 2005
1-51
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2016
No response from the arm control board.
Request is sent to the 1KB board from the 1KA board and there is no response.
⇒ Reset error and if error recurs, replace the 1KA/1KB boards.
_____________________________________________________________________
ERROR CODE D2017
1KA board software stopped.
Main causes include:
No response from User I/F board.
1. AS software is not installed correctly or is corrupt.
2. Defective 1KA board.
⇒ Reinstall correct AS software.
⇒ Replace 1KA board.
_____________________________________________________________________
ERROR CODE D2018
1KB board software stopped.
Main causes include:
[ARM CTRL BOARD] no response.
1. AS software is not installed correctly or is corrupt.
2. Defective 1KB board.
⇒ Reinstall correct AS software.
⇒ Replace 1KB board.
_____________________________________________________________________
ERROR CODE D2019
1KB board software stopped.
Main causes include:
[ARM CTRL BOARD] servo software no response.
1. Servo software is not installed correctly or is corrupt.
2. Defective 1KB board.
⇒ Reinstall correct 1KB board servo software to the 1KA board.
⇒ Replace 1KB board.
_____________________________________________________________________
1-52
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2020
1KB board software stopped.
Main causes include:
[ARM CTRL BOARD] servo control software no response.
1. Servo software is not installed correctly or is corrupt.
2. Defective 1KB board.
⇒ Reinstall correct 1KB board servo software to the 1KA board.
⇒ Replace 1KB board.
_____________________________________________________________________
ERROR CODE D2021
Arm data file is not found.
When robot model is selected, data file corresponding to the installed arm is not found
in the system file.
⇒ Contact KRI customer service (include operating conditions/settings at the time the
error occurred).
_____________________________________________________________________
ERROR CODE D2022
Arm data is not found.
When robot model is selected, the arm data in the arm data file did not match the se-
lected robot.
⇒ Ensure the correct model setting is used.
⇒ Ensure the correct software version is installed.
_____________________________________________________________________
ERROR CODE D2023
Failed to load arm data.
When robot model is selected, the arm data file for the selected robot model is incom-
patible with the AS software.
⇒ Ensure the correct model setting is used.
⇒ Ensure the correct software version is installed.
_____________________________________________________________________
August 9, 2005
1-53
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2024
[ARM CTRL BOARD] robot type setting failed.
System software is not compatible with the robot model set in the AS software.
⇒ Ensure the correct model setting is used.
⇒ Ensure the correct software version is installed.
_____________________________________________________________________
ERROR CODE D2025
Robot codes set in software and Arm ctrl board do not
match.
Robot model hardware and software settings do not match.
⇒ Ensure 1KB board dip switch S2 setting is correct.
⇒ Use AUX 0804 or AS Language ID monitor command to ensure correct software
version is installed.
_____________________________________________________________________
ERROR CODE D2026
Code set in software & curr. sensor I/F b’d do not match.
1GM daughter board on the 1KB board does not match hardware or software settings.
⇒ Ensure correct 1GM board is installed.
⇒ Ensure 1KB board dip switch S2 setting is correct.
⇒ Use AUX 0804 or AS Language ID monitor command to ensure correct software
version is installed.
_____________________________________________________________________
ERROR CODE D2027
Codes set in software and power block do not match.
Power block settings and hardware or software settings do not match.
⇒ Ensure correct power block is installed.
⇒ Ensure power block jumper settings are correct.
⇒ Use AUX 0804 or AS Language ID monitor command to ensure correct software
version is installed.
_____________________________________________________________________
1-54
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2028
(SSCNET) initialization error. (code XX).
The Mitsubishi single axis amplifier failed to initialize at controller power-up. A 2 byte
code follows the error message. The higher byte indicates axis number and the lower
byte indices the error code.
Higher byte:
0: system error.
Any other number: axis number that caused error.
Lower byte:
1: 1LP daughter board not installed to 1KB board.
3: Mitsubishi amplifier/motor not connected to the specified axis.
2, 4, 5: Other problems.
⇒ Lower byte 1: install 1LP board.
⇒ Lower byte 3: connect amplifier or motor.
⇒ Lower byte 2, 4, 5: replace the 1LP board, amplifier or motor.
_____________________________________________________________________
ERROR CODE D2029
Motor codes in software & Arm control b’d mismatch. (Jt-A)
Software and hardware motor code settings, of axis assigned to channel 7 (seventh
axis), do not match.
⇒ Ensure 1KB board dip switch S8 setting is correct.
⇒ Ensure correct AS and servo software are installed.
_____________________________________________________________________
ERROR CODE D2030
Codes set in software and curr. sensor I/F b’d mismatch.
(Jt-A)
Software and hardware settings, for the axis assigned to channel 7 (seventh axis), do
not match 1KV board settings.
⇒ Ensure 1KB board dip switch S8 setting is correct.
⇒ Ensure correct AS and servo software are installed.
_____________________________________________________________________
August 9, 2005
1-55
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2031
Codes set in software and on add’l pwr block mismatch.
(Jt-A)
Software and hardware settings, for the axis assigned to channel 7 (seventh axis), do
not match power block settings.
⇒ Ensure correct power block is installed.
⇒ Ensure power block jumper settings are correct.
⇒ Use AUX 0804 or AS Language ID monitor command to ensure correct software
version is installed.
_____________________________________________________________________
ERROR CODE D2032
Motor codes set in software and Arm ctrl b’d. (Jt-B)
Software and hardware motor code settings, for the axis assigned to channel 8 (eight
axis), do not match.
⇒ Ensure 1KB board dip switch S8 setting is correct.
⇒ Ensure correct AS and servo software are installed.
_____________________________________________________________________
ERROR CODE D2033
Codes set in software & curr. sensor I/F b’d mismatch.
(Jt-B)
Software and hardware settings for the axis assigned to channel 8 (eight axis) do not
match 1KV board settings.
⇒ Ensure 1KB board dip switch S8 setting is correct.
⇒ Ensure correct AS and servo software are installed.
_____________________________________________________________________
ERROR CODE D2034
Codes set in software and on add’l pwr block mismatch.
(Jt-B)
Software and hardware settings for the axis assigned to channel 8 (eight axis) do not
match power block settings.
⇒ Ensure power block jumper settings are correct.
⇒ Ensure correct AS and servo software are installed.
_____________________________________________________________________
1-56
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D2035
Program execution error.
Program failed to start when cycle start command was issued.
⇒ Reset the error, and restart the program.
⇒ If the error recurs, contact KRI Customer Service.
_____________________________________________________________________
ERROR CODE D2036
(SSCNET) system error occurred in 1LP I/F board. (code
XX)
Main causes include:
1. Defective 1LP board (1KB daughter board)
2. 5 VDC power supply voltage dropped to 4.5 VDC or less.
⇒ Replace 1LP board.
⇒ Adjust 5 VDC power supply to specifications then cycle controller power OFF and
ON.
_____________________________________________________________________
ERROR CODE D4500
Fieldbus interface board is not detected.
The I/F board specified in AUX 0608-2 is not installed.
⇒ Set controller power OFF and install the specified I/F board.
⇒ If specified I/F board is installed, verify proper installation.
⇒ Ensure settings in AUX 0608-2 are correct.
⇒ Ensure I/F board LED indicator displays proper operation.
⇒ Ensure 1JF board jumper settings are correct.
_____________________________________________________________________
ERROR CODE D4501
ABMA-PDP) I/F module error. XX
Improperly installed or defective ABMA-PDP module
⇒ Check error code.
⇒ Ensure 1JF board and I/F board are properly installed and cycle controller power
OFF and ON.
⇒ If error recurs, check LED1 on the I/F card.
If the LED is ON, execute configuration.
If the LED is OFF, contact I/F card manufacturer.
_____________________________________________________________________
August 9, 2005
1-57
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE D4502
FIELD-BUS-INIT) Error Reply. XX
At fieldbus start-up, a mismatch in length of I/O data with the node at the end of the
connection is detected when a message is sent to the fieldbus I/F card, or maximum
I/O data length is exceeded.
⇒ Check the I/F card LED display. Match the I/O data length with the master.
⇒ Ensure I/O data length is within length specified for the fieldbus I/F card.
⇒ Cycle controller power OFF and ON.
⇒ Replace fieldbus cable.
⇒ If this error recurs, contact KRI Customer Service (include sub-code XX).
_____________________________________________________________________
ERROR CODE D4503
FIELD-BUS-INIT) Reply timeout XX.
At fieldbus start-up, no response is detected due to defective hardware or incorrect
settings during I/F board initialization.
⇒ Check the I/F card LED display.
⇒ Ensure the master and slave I/O data length match.
⇒ Cycle controller power OFF and ON.
⇒ Replace the fieldbus cable.
⇒ If this error recurs, contact KRI Customer Service (include sub-code XX).
_____________________________________________________________________
ERROR CODE D4504
ANYBUS) OUT/FB.CTRL request timeout. XX
Reading input signal area access is requested but denied due to hardware problem.
⇒ Check the I/F card LED display and reset the error.
⇒ If this error cannot be reset, contact KRI Customer Service (include sub-code XX).
_____________________________________________________________________
1-58
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.3.2.2 EXXXX NON-FATAL ERROR CODES
ERROR CODE E0001
Unknown error.
Unregistered error occurred.
⇒ Contact KRI customer service (include operating conditions/settings and operation
log at the time the error occurred).
_____________________________________________________________________
ERROR CODE E0100
Abnormal comment statement exists.
Statements containing incorrect AS Language syntax can be included in a program as
comments. If the comment is not preceded with a semicolon (;) the step is executed as
a step and an error is generated.
⇒ Correct program comment syntax (add preceding semicolon).
⇒ Delete incorrect program step.
_____________________________________________________________________
ERROR CODE E0101
Nonexistent label.
Occurs when executing a GOTO command and the destination label is not defined.
Example: “IF x>0 GOTO 10” is specified, but the label “10” is not included in a program
step an error is generated.
⇒ Ensure valid labels are used within the program.
⇒ Delete the reference to the nonexistent label.
_____________________________________________________________________
ERROR CODE E0102
Variable is not defined.
Main causes include:
1. Variable data for a specific command/instruction is not defined.
Example: “x=SIN(y)” is specified and “y” is not defined.
2. Command/instruction contains incorrect AS Language syntax.
Example: “PCEND pcprog1” should be “PCEND 1”.
⇒ Ensure variables are properly defined.
⇒ Ensure correct AS Language command/instruction syntax is used.
_____________________________________________________________________
August 9, 2005
1-59
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E0103
Location data is not defined.
Main causes include:
1. The location variable for the BASE, TOOL or POINT command is not specified.
Example: “TOOL a” is specified and “a” is not defined.
2. DEST or #DEST function is used and the destination data is not defined.
⇒ Ensure all locations used in programs and functions are defined.
_____________________________________________________________________
ERROR CODE E0104
String variable is not defined.
String variables evaluated by ASC and LEN functions are not defined.
Example: “ASC(“$sample”)” is specified and “$sample” is not defined.
⇒ Define the string variables to be evaluated or correct the name of the string variable
used for evaluation.
_____________________________________________________________________
ERROR CODE E0105
program or label is not defined.
The program name or label associated with an ON or ONI command does not exist.
⇒ Define the program or label used with the ON or ONI command.
_____________________________________________________________________
ERROR CODE E0106
Value is out of range.
The numeric value entered exceeds the upper or lower limits of the acceptable range.
Example: “SPEED 10000” exceeds maximum value of 100.
⇒ Enter data that is within acceptable range.
_____________________________________________________________________
ERROR CODE E0107
No array suffix.
Attempt to process an array variable with undefined suffixes, i.e., attempting to process
A=B[C,D,E], but C, D, E have no values.
⇒ Rewrite the program to define the array suffix before attempting to process the array.
_____________________________________________________________________
1-60
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E0108
Divided by zero.
Occurs when the system encounters a mathematical evaluation that involves division by
“0”. Typically associated with the FRAME function and circular interpolation.
⇒ Check data source for calculations.
_____________________________________________________________________
ERROR CODE E0109
Floating point overflow.
Occurs when the system encounters a numeric floating point overflow in using arith-
metic (+, -, *, /) or logical (AND, OR, etc.) operators. This also occurs when converting a
numeric argument to an integer value.
⇒ Correct the program. Integer values with full precision ranges are from -16,777,216
to 16,777,216. For more information refer to the D Series Controller AS Language
Reference Manual.
_____________________________________________________________________
ERROR CODE E0110
String too long.
Character strings associated with arithmetic or comparative operators or the LEN func-
tion are too long (255 character maximum).
⇒ Correct the character string.
_____________________________________________________________________
ERROR CODE E0111
Attempted operation with neg. exponent.
Numeric values that have exponents must be positive in value.
⇒ Correct equations in program.
_____________________________________________________________________
ERROR CODE E0112
Too complicated expression.
Encountered numeric calculation too complex to be evaluated.
⇒ Simplify mathematical equations.
_____________________________________________________________________
August 9, 2005
1-61
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E0113
No expressions to evaluate.
The type of data in an argument is incompatible with the operation being performed.
⇒ Correct the program to evaluate compatible expressions.
_____________________________________________________________________
ERROR CODE E0114
SQRT parameter is negative.
In the argument of a SQRT function, a negative number is entered for evaluation.
Example: “x=SQRT(-2)” causes an error. “x=SQRT(2)” is acceptable.
⇒ Do not enter negative numbers for SQRT function evaluation.
_____________________________________________________________________
ERROR CODE E0115
Array suffix value outside range.
Occurs when the array suffix number exceeds the acceptable range from 0 to 9999.
Example: “DECOMPOSE x[10000]=a” causes an error. “DECOMPOSE x[1]=a” is ac-
ceptable.
⇒ Ensure the range of array suffixes are acceptable.
_____________________________________________________________________
ERROR CODE E0116
Faulty or missing argument value.
Displayed when the parameter specified for a command or an instruction is illegal.
Example: “TOOL 2112” (after the TOOL command a defined transformation location or
null is expected, 2112 causes an error).
⇒ Use correct argument values.
_____________________________________________________________________
ERROR CODE E0117
Incorrect joint number.
The joint number entered does not exist or is in the wrong format.
⇒ Retype the command using the correct joint number and format.
_____________________________________________________________________
1-62
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E0118
Too many subroutine calls.
Occurs when more than 20 subroutines are nested with EXTCALL or CALL instructions.
⇒ Do not exceed 20 nested subroutines.
_____________________________________________________________________
ERROR CODE E0119
Nonexistent subroutine.
Displayed when the program specified by a CALL, ON, or ONI instruction does not exist.
⇒ Select only existing programs to be run as subroutines.
_____________________________________________________________________
ERROR CODE E0903
Check sum error of system data.
The check sum of the system data of the AS software is changed when the system
information such as model number, number of axes, and option setting is downloaded.
When the error occurs in situations other than software download, the error is caused by
defective memory battery back-up, defective 1KA board, or memory error from noise.
⇒ Use AUX 0803 Clear Check Sum Error or CHSUM command to reset the data. When
the error cannot be reset using the check sum commands, the command with the
abnormality is shown. Rewrite the command and use CHSUM or AUX 0803 to clear
the error.
⇒ Check the memory backup battery. Replace if necessary.
⇒ Replace the 1KA board if the error recurs.
NOTE
A robot data sheet is supplied with each robot. The ro-
bot data sheet contains a list of factory settings and can
be used to reenter orignal factory settings. If system
data or options change the robot data sheet should be
updated to provide correct robot information when
needed.
_____________________________________________________________________
ERROR CODE E1000
ADC channel error.
This error occurs when an A/D converter channel number other than 1–8 is used.
⇒ Ensure the correct A/D converter channel number is used (1–8).
_____________________________________________________________________
August 9, 2005
1-63
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1001
ADC input range error.
This error occurs when an A/D converter input voltage is incorrect.
The correct analog input voltage ranges are:
1. 0– +10 V
2. 5 V
3. 10 V
⇒ Ensure the correct analog input voltage range is used.
_____________________________________________________________________
ERROR CODE E1002
PLC interface error.
This error occurs when signal communication is not available between the 1KA board
and the PC3JB board (TOYOPUC PLC).
NOTE
When this error occurs, set motor power to OFF to pre-
vent external signal input.
⇒ Replace PC3JB (TOYOPUC PLC).
⇒ Replace 1KA board.
_____________________________________________________________________
ERROR CODE E1003
Built-in PLC is not installed.
[Option: PC3JB (PLC) correspondence]
Main causes include:
1. The system checks for proper installation and operation of the PC3JB board
(TOYOPUC PLC) on power-up.
2. This error occurs if PLCSAVE or PLCLOAD is executed and the PC3JB board
(TOYOPUC PLC) is not installed.
3. This error occurs if the PC3JB board (TOYOPUC PLC) is not installed and operating
properly.
⇒ Replace PC3JB (TOYOPUC PLC).
⇒ Replace 1KA board.
_____________________________________________________________________
1-64
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1004
Interbus board is not ready.
At 1JF board start-up, the board did not achieve the ready state within the required time.
⇒ Cycle controller power OFF and ON.
⇒ Ensure the 1JF board is correctly installed.
⇒ Replace the 1JF board.
_____________________________________________________________________
ERROR CODE E1005
Spin axis encoder difference error.
At controller power-up or RTSET execution, the current value is substantially different
than the calculated encoder value for the spin axis.
⇒ Perform the spin axis zeroing procedure (zeroing data is not set). Refer to the Spin
Control Function (Option) Manual for the spin axis zeroing procedure.
_____________________________________________________________________
ERROR CODE E1006
Touch panel switch is short-circuited.
This error occurs if a touch panel key is pressed or the TEACH/REPEAT switch position
is changed during controller power-up.
⇒ Do not touch any touch panel keys or change the position of the TEACH/REPEAT
switch during controller power-up.
⇒ Replace the teach pendant.
_____________________________________________________________________
ERROR CODE E1007
Power sequence board is not installed.
The first address of the No.1 1KP power sequence board cannot be read at controller
power-up.
Main causes include:
1. The 1KP power sequence board is not installed in the correct card slot.
2. Jumper or dip switch settings of the 1KP power sequence board are incorrect.
3. Defective 1KP power sequence board.
⇒ Ensure the 1KP board DSW1 setting is configured as power sequence board No. 1
and is installed in the 1KP card rack slot. Check and replace the board if necessary.
_____________________________________________________________________
August 9, 2005
1-65
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1008
No.2 power sequence board is not installed.
The first address of the No.2 1KP power sequence board cannot be read at controller
power-up.
Main causes include:
1. The 1KP power sequence board is not installed in the correct card slot.
2. Jumper or dip switch settings of the 1KP power sequence board are incorrect.
3. Defective 1KP power sequence board.
⇒ Ensure the 1KP board DSW1 setting is configured as power sequence board No. 2
and is installed in the No. 2 1KP card rack slot. Check and replace the board if nec-
essary.
_____________________________________________________________________
ERROR CODE E1009
No. XX I/O board is not installed.
Cannot read the first addresses of I/O boards (1GW/1HW) based on the number of
signals that have been set in AUX 0611 or with DO (output point), or DI (input point) of
the ZSIGSPEC command, at controller power-up. This error is not used when a 1FS
board is installed.
Main causes include:
1. Incorrect value set in AUX 0611 or with the ZSIGSPEC command.
2. Error in board address of I/O board (1GW/1HW).
3. Defective I/O board or I/O board not installed (1GW/1HW board, etc.).
⇒ Set the correct number of signals in AUX 0611 or with the ZSIGSPEC command. I/O
cards are typically mounted in the card rack from right to left in ascending order.
Because of VME buss communication, this is not critical. The robot can run without
I/O boards. The maximum number of signals in the software set in AUX 0611, or with
the ZIGSPEC command, is DO, DI=256, INT=512, but DO and DI are restricted by
hardware and other options.
⇒ Set board address jumpers correctly.
⇒ Replace the 1GW/1HW board.
_____________________________________________________________________
1-66
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1010
Power sequence board detects error.
An error signal, not classified through the error summary, is generated by the 1KP board
and is sent to the 1KB board. This error occurs when the error signal sent from the 1KP
board is not recognized by the AS software.
Main causes include:
1. The error detection function of the 1KP power sequence board does not correspond
to the error processing function of the AS software.
2. AS software is not installed correctly or is corrupt.
3. Defective 1KP power sequence board.
4. Defective 1KB board.
⇒ Ensure the correct version of AS software is installed.
⇒ Replace the 1KP power sequence board.
⇒ Replace the 1KB board.
_____________________________________________________________________
ERROR CODE E1011
Built-in sequence board is not installed.
Installation of the built-in (Sharp) sequence board is checked at controller power-up.
⇒ Install the built-in (Sharp) sequence board.
⇒ Ensure the built-in (Sharp) sequence board is properly installed.
⇒ If the built-in (Sharp) sequence board is not used, change the settings so the control-
ler does not check for the built-in (Sharp) sequence board.
NOTE
The PC3JB board (TOYOPUC PLC) is not recognized
as a built-in sequence board.
_____________________________________________________________________
ERROR CODE E1012
RI/O board or C-NET board is not installed.
This error occurs at controller power-up and the first address of the RI/O board is not
read (1GW/1HW, 1FS etc.).
1. The RI/O or C-Net board is not installed.
2. Defective RI/O or C-Net board.
⇒ Ensure the RI/O or C-Net board is installed.
⇒ Replace the RI/O or C-Net board.
_____________________________________________________________________
August 9, 2005
1-67
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1013
InterBus board is not installed.
The 1JF board is not installed.
⇒ Ensure the 1JF board is properly installed.
⇒ Replace the 1JF board.
_____________________________________________________________________
ERROR CODE E1016
No. XX CC-LINK board is not installed.
The specified number 1HS board is not installed.
⇒ Installed the specified number 1HS board.
⇒ Ensure the specified number 1HS board is properly installed.
⇒ Replace the specified number 1HS board.
_____________________________________________________________________
ERROR CODE E1017
PLC error. Error code is Hex. XX.
This error occurs when a PC3JB (TOYOPUC) internal error is present (program memory
check sum error, parameter setting error, etc.).
⇒ Refer to the PC3JB (TOYOPUC) manual for the code (Hex. XX).
⇒ Replace the PC3JB (TOYOPUC).
_____________________________________________________________________
ERROR CODE E1018
INTER-BUS status error.
A processing error such as cable disconnection is detected at the 1JF board during
communication.
⇒ Refer to the 1JF board manual for information for checking error state displayed by
the front LED.
⇒ Replace the 1JF board.
_____________________________________________________________________
ERROR CODE E1020
External equipment is abnormal.
An abnormality in peripheral equipment is detected by the PC3JB board (TOYOPUC).
⇒ Check PC3JB board (TOYOPUC) peripheral equipment connections.
⇒ Ensure proper installation and connection of peripheral equipment.
_____________________________________________________________________
1-68
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1021
Arm ID board error. (code XXX).
Code
4AH
4FH
C1H
C5H
C6H
FFH
Description
Arm ID board data is not normal or is corrupt
Writing error to arm ID board memory1
Communication check sum error2
Communication protocol error2
Communication response time-out error2
Other errors (unknown error)3
1Cannot write to arm ID board memory. Replace arm ID board.
2Damaged or disconnected communication cable.
3F*H cycle controller power ON and OFF. If error does not
clear, further diagnosis is needed (possible damaged arm ID
board or power sequence board).
Main causes include:
1. Defective harness.
2. Defective serial flash memory on the 1GV board.
3. Defective 1GV board.
4. Defective 1KP board.
⇒ Replace harness.
⇒ Replace serial flash memory on the 1GV board.
⇒ Replace 1GV board.
⇒ Replace 1KP board.
_____________________________________________________________________
ERROR CODE E1022
Power sequence board error. (code XX)
Main causes include:
1. Defective harness.
2. Defective 1KP board.
⇒ Replace harness.
⇒ Replace 1KP board.
_____________________________________________________________________
August 9, 2005
1-69
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1023
Communication error in robot network.
Main causes include:
1. Communication between robots is not normal during cooperative motion operation.
2. Power to one of the controllers connected to the network is not set ON.
⇒ Ensure network cables and connections are correct.
⇒ Ensure robot network settings are correct.
⇒ Ensure power for all controller connected to the network is set ON.
_____________________________________________________________________
ERROR CODE E1024
EXT.AXIS release sequence error. (code XX)
Occurs when a gun disconnect is not normally completed.
Code
0
Description
No response from servo software.
EF**
FF**
EE**
FE**
ED**
FD**
200
Could not be executed because RGSO is ON.
Could not be executed because RGSO is ON.
Code pertaining to other than release/connection.
Code pertaining to other than release/connection.
Release/connection operation did not complete normally.
Release/connection operation did not complete normally.
Gun did not return within motion range after calibration.
Main causes include:
1. No response from servo software at external axis release.
2. Defective 1KB board.
3. Defective 1KP board.
⇒ Check cables and replace as necessary.
⇒ Replace the 1KB board.
⇒ Replace the 1KP board.
⇒ Reinstall servo software.
_____________________________________________________________________
1-70
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1025
EXT AXIS connecting error. (code XX)
Occurs when the gun axis connection is not normally completed.
Code
0
Description
No response from servo software.
EF**
FF**
EE**
FE**
ED**
FD**
200
Could not be executed because RGSO is ON.
Could not be executed because RGSO is ON.
Code pertaining to other than release/connection.
Code pertaining to other than release/connection.
Release/connection operation did not complete normally.
Release/connection operation did not complete normally.
Gun did not return within motion range after calibration.
Main causes include:
1. Motion range for gun or the limit value for clamping force is not set correctly.
2. Defective gun or gun brake circuit.
3. No response from servo software.
4. Defective 1KB board.
5. Defective 1KP board.
⇒ Verify that the servo gun’s upper and lower limits are correctly set in AUX 1011.
⇒ Use the gun brake release switch, release the gun’s brake. Manually move the gun to
check for mechanical binding.
⇒ Adjust the clamping force in AUX 1021.
⇒ Reinstall the servo software.
⇒ Check brake circuit and repair as necessary.
⇒ Replace the 1KB board.
⇒ Replace the 1KP board.
_____________________________________________________________________
ERROR CODE E1026
Main CPU mismatch.
This error occurs when the are conflicting CPU cache settings.
⇒ Change the CPU cache setting to “No” and cycle controller power OFF and ON.
⇒ Use the ZCPUCACH instruction to set the CPU cache setting to “OFF”.
_____________________________________________________________________
August 9, 2005
1-71
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1027
Safety circuit was cut OFF.
The safety gate branch of the safety circuit is open due to a missing safety plug or
defective circuit.
⇒ Reinsert the safety plug.
⇒ Repair open circuit.
_____________________________________________________________________
ERROR CODE E1028
Jt XX Motor overload.
The current feedback from the power block exceeded maximum continuous ratings
longer than the time allowed.
1GM board
Servo
I/V
Time
CPU
converter
ABNORMAL
Current
feedback
1KB board
Motor current
Continuous
current rating
Current
sensor
U, V, W earth
IPM
Motors
Overload Curve
Power block
Robot
Main causes include:
Mechanical-
1. The robot arm has contacted an external item hindering movement.
2. The harness is caught in the robot arm.
3. The cyclo reduction unit, the gear, or the bearing(s) are damaged.
4. Gear cyclo reduction unit backlash is too narrow.
5. Payload weight exceeds robot specifications for capacity.
6. Robot motion pattern exceeds ratings of the motor.
7. Motor brake is not released.
Electrical-
1. Motor power line U, V, and W phase are disconnected.
2. The brake line is disconnected or brake drive circuit is damaged.
3. The power block is damaged.
4. Defect in the 1KQ/1NR board.
5. Defect in the 1KB servo board.
1-72
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
6. Malfunction of the motor.
7. Servo spot weld gun:
–Clamping pressure and/or clamping time is excessive.
–Distance between weld points is short; the motor does not have time to cool suffi-
ciently between welds.
–Clamping pressure setting exceeds the servo gun motor power capacity.
⇒ Check the cyclo reduction unit, the gear, or the bearing(s) for mechanical failure.
Replace as necessary.
⇒ Re-teach the robot motion as necessary.
⇒ Check the harness and servo unit for electrical malfunctions and replace if necessary.
⇒ Replace the 1KB board.
⇒ Replace the 1KQ/1NR board.
Servo Spot Weld Gun
⇒ If the weld points are close to each other, set a time delay. This provides a cool-down
period for the servo gun motor.
⇒ Set the clamping force lower (see servo gun manufacturer’s specifications).
_____________________________________________________________________
August 9, 2005
1-73
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1029
Encoder rotation data is abnormal. (Jt XX)
Occurs when there is a difference (+2 rotations or more) between the rotation data in
the serial encoder data and the rotation data calculated using the incremental tech-
nique.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
⇒ Check connections at encoder, 1FG/1HG board, and separation harness.
⇒ Check for noise and shield integrity.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Check for continuity in the machine harness and separation harness.
⇒ Replace 1FG/1HG board.
⇒ Replace the 1KB board.
⇒ Replace the encoder.
For additional information on error code E1029, see section 1.4.
_____________________________________________________________________
1-74
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1030
Encoder data abnormal. (Jt XX)
When control power is switched ON, the current encoder value is compared to the
stored encoder value when the power is turned OFF. If the difference is more than the
value set in AUX 0504 Encoder Error Range, or by the ENCCHK_DATA command, this
error occurs.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Value set in AUX 0504 is to small.
2. Back up battery failure due to disconnection or discharged battery (+3.3 VDC or less).
3. Control power is turned off during robot motion by an abnormal power supply, etc.,
causing the robot to stop in a position other than the last position stored in the AS
software.
4. Motor replacement/encoder replacement (zeroing must be performed).
5. Robot arm or motor operated by force when control power is off.
6. Controller was initialized (this error occurs for all axes).
7. Servo spot weld gun.
–Loose connection at tool changer.
–Defective tool changer harness.
⇒ Ensure the value set in AUX 0504 is correct.
⇒ Data may have been lost due to backup battery. See error W1013. Replace the
battery. There is a possibility that internal encoder data may be lost. Check the robot
zeroing.
⇒ Check connections at tool changer, clean connections, replace harness as neces-
sary.
⇒ Check each harness for short circuit and repair, or replace, as necessary.
⇒ Replace the encoder, the 1KB board or the 1FG/1HG encoder battery backup board
as necessary.
⇒ After repair is complete, confirm correct program playback in check mode before
running program in repeat mode.
_____________________________________________________________________
August 9, 2005
1-75
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1031
Miscount of encoder data (Jt XX).
The servo gun or tool changer harness is defective.
⇒ Inspect the servo gun and tool changer harnesses; replace if necessary.
_____________________________________________________________________
ERROR CODE E1032
Mismatch ABS and INC encoder data (Jt XX).
Occurs when there is a large difference between the value in the serial encoder data
and the calculated data using the incremental technique.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Defective encoder or encoder harness.
2. Defective 1KB board.
3. Noise related malfunction.
4. Defective 1FG/1HG board.
5. Servo spot weld gun.
–Loose connection at tool changer.
–Defective tool changer harness.
⇒ Replace encoder, replace 1KB board.
⇒ Check connections at encoder, 1FG/1HG board, and separation harness.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Check for continuity in the machine harness and separation harness.
⇒ Check for noise and shield integrity.
⇒ Replace 1FG/1HG board.
For additional information on error code E1032, see section 1.4.
_____________________________________________________________________
1-76
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1034
Encoder initialize error (Jt XX).
The encoder is not able to read the absolute position at control power on. The scanning
of absolute data begins immediately after a shift from the state of non-operation, or
back-up operation, to normal encoder operation. BUSY=1 is output until the absolute
position has been determined.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Encoder rotated at 300 RPM or more at controller power-up (including conveyor
encoder).
2. Defective encoder or encoder harness.
3. Defective 1KB, 1KQ/1NR, or 1GF/1HG board.
4. Defective manual brake release.
⇒ In the case of a conveyor encoder, ensure power-up speed is below 300 RPM.
⇒ Check connections at encoder, 1FG/1HG board.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Replace encoder, replace 1KB, 1KQ/1NR, or 1FG/1HG board.
⇒ Check for continuity in the machine harness, separation and signal harness repair or
replace as necessary.
For additional information on error code E1034, see section 1.4.
_____________________________________________________________________
August 9, 2005
1-77
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1035
Encoder response error (Jt XX).
Occurs when the encoder does not respond, or response is slow, to data request signal
from the 1KB board.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Defective encoder or encoder harness.
2. Defective 1KB or 1FG/1HG board.
3. Noise related malfunction.
4. Servo spot weld gun.
–Loose connection at tool changer.
–Defective tool changer harness.
⇒ Check connections at encoder, 1FG/1HG board, and separation harness.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Replace encoder, replace 1KB board.
⇒ Check for continuity in the machine harness and separation harness.
⇒ Replace 1FG/1HG board.
⇒ Check for noise malfunction and shield integrity.
⇒ Inspect the servo gun and tool changer harnesses; replace as necessary.
⇒ After repair is complete, confirm correct program playback in check mode before
running program in repeat mode.
For additional information on error code E1035, see section 1.4.
_____________________________________________________________________
1-78
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1036
Encoder communication error. (Jt XX)
Cyclic redundancy check (CRC) fault or framing error is detected in communication with
the encoder.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Noise related malfunction.
2. Defective encoder or encoder harness.
3. Defective 1KB or 1FG/1HG board.
4. Servo spot weld gun.
–Loose connection at tool changer.
–Defective tool changer harness.
⇒ Check for noise malfunction and shield integrity.
⇒ Check connections at encoder, 1FG/1HG board, and separation harness.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Replace encoder, replace 1KB board.
⇒ Check for continuity in the machine harness, separation harness and signal harness.
⇒ Replace 1FG/1HG board.
⇒ Inspect the servo gun and tool changer harnesses; replace as necessary.
⇒ After repair is complete, confirm correct program playback in check mode before
running program in repeat mode.
For additional information on error code E1036, see section 1.4.
_____________________________________________________________________
August 9, 2005
1-79
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1037
Encoder data conversion error. (Jt XX).
This error is caused by abnormal encoder absolute position data.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Noise related malfunction.
2. Defective encoder or encoder harness.
3. Defective 1KB or 1FG/1HG board.
4. Servo spot weld gun.
–Loose connection at tool changer.
–Defective tool changer harness.
⇒ Check for noise malfunction and shield integrity.
⇒ Replace encoder, replace 1KB board.
⇒ Check connections at encoder, 1FG/1HG board, and separation harness.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Check for continuity in the machine harness and separation harness.
⇒ Replace 1FG/1HG board.
⇒ Inspect the servo gun and tool changer harnesses; replace as necessary.
⇒ After repair is complete, confirm correct program playback in check mode before
running program in repeat mode.
For additional information on error code E1037, see section 1.4.
_____________________________________________________________________
1-80
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1038
Encoder ABS-track error. (Jt XX)
The absolute data and the incremental data in the encoder are different. ABSALM=1 is
output from the encoder when this error occurs.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Noise related malfunction.
2. Defective encoder or encoder harness.
3. Defective 1KB or 1FG/1HG board.
4. Servo spot weld gun.
–Loose connection at tool changer.
–Defective tool changer harness.
⇒ Check for noise malfunction and shield integrity.
⇒ Replace encoder, replace 1KB board.
⇒ Check connections at encoder, 1FG/1HG board, and separation harness.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Check for continuity in the machine harness and separation harness.
⇒ Replace 1FG/1HG board.
⇒ Inspect the servo gun and tool changer harnesses; replace as necessary.
For additional information on error code E1038, see section 1.4.
_____________________________________________________________________
August 9, 2005
1-81
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1039
Encoder INC-pulse error. (Jt XX)
Occurs when the encoder A and B incremental pulses are abnormal. The encoder
INALM bit is sent with the serial data=1.
Encoder Encoder
Servo
Encoder I/F
CPU
Power
circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Noise related malfunction.
2. Defective encoder or encoder harness.
3. Defective 1KB or 1FG/1HG board.
4. Servo spot weld gun.
–Loose connection at tool changer.
–Defective tool changer harness.
⇒ Replace encoder, replace 1KB board.
⇒ Check connections at encoder, 1FG/1HG board, and separation harness.
⇒ Ensure the 1KB board is properly seated into the card rack.
⇒ Check for continuity in the machine harness and separation harness.
⇒ Replace 1FG/1HG board.
⇒ Inspect the servo gun and tool changer harnesses; replace as necessary.
For additional information on error code E1039, see section 1.4.
_____________________________________________________________________
ERROR CODE E1040
Encoder MR-sensor error. (Jt XX)
The state of the MR sensor in the encoder does not match with JT ENCODER in one
rotation.
⇒ Replace the encoder or encoder harness.
⇒ Replace signal harness.
⇒ Replace 1KB board.
_____________________________________________________________________
1-82
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1041
Limit switch (JT XX) is ON.
This error occurs when the robot moves beyond the set working range (restricted space)
and activates the axis restriction limit switch.
The mechanical stopper and the axis restriction limit switch are optional and the axis
they are installed on varies with machine type and configuration.
1KB board
Axis
restriction
LS
Axis
restriction
LS
Local bus
Controller
EPLD
1FG/1HG board
Robot
1KX board
1KP board
Main causes include:
1. Software limits are set incorrectly in AUX 0507.
2. Axis is moved using the manual brake release and the limit switch is turned ON.
3. The limit switch is turned ON by overshoot from inertia.
4. Incorrect zeroing data.
5. Defective axis restriction limit switch or signal harness.
6. Defective 1KP board.
⇒ Check the limit switch and limit switch harness; replace as necessary.
⇒ Set the software limits in AUX 0507 to an appropriate value.
⇒ Change the installation angle of the axis restriction limit switch to an appropriate
value.
⇒ Replace the 1KP power sequence board.
⇒ Return robot within the motion range using the manual brake release or press and
hold the overtravel override switch on the 1KP board, reset the error, set motor power
ON in teach mode and jog the robot off of the axis restriction limit switch.
_____________________________________________________________________
August 9, 2005
1-83
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1042
Limit switch signal line is disconnected.
This error occurs when the axis restriction limit switch is activated and the robot did not
move beyond the set working range (restricted space).
The mechanical stopper and the axis restriction limit switch are optional and the axis
they are installed on varies with machine type and configuration.
1KB board
Axis
restriction
LS
Axis
restriction
LS
Local bus
Controller
EPLD
1FG/1HG board
Robot
1KX board
1KP board
Main causes include:
1. Axis restriction limit switch activated by brake release or unexpected robot motion.
2. Axis restriction limit switch installed inside motion range set in AUX 0507.
3. Incorrect zeroing data.
4. Defective axis restriction limit switch.
5. Defective signal harness.
6. Defective 1KP board.
⇒ Set the software limits in AUX 0507 to an appropriate value.
⇒ Change the installation angle of the axis restriction limit switch to an appropriate
value.
⇒ Check harness and limit switch and replace as necessary.
⇒ Replace the 1KP power sequence board.
⇒ Return robot within the motion range using the manual brake release or press and
hold the overtravel override switch on the 1KP board, reset the error, set motor power
ON in teach mode and jog the robot off of the axis restriction limit switch.
_____________________________________________________________________
ERROR CODE E1043
Teach-plug is abnormal.
This error occurs in teach mode if the teach plug is not installed or in repeat mode if the
teach plug is connected.
⇒ Ensure the teach-plug is in the proper state for the mode used.
⇒ Check and repair the teach-plug circuit as necessary.
_____________________________________________________________________
1-84
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1045
Gun-clamp Mismatch.
(Spot weld specifications type B)
Spot weld is not selected in AUX 0605-1 when a servo spot weld gun is used.
⇒ Ensure spot weld is selected in AUX 0605-1.
_____________________________________________________________________
ERROR CODE E1046
Too short distance between start point and end point.
(sensing function)
In a work sensing step, the final end point determined by overrun distance could not be
defined because the end point and start point are too close together.
⇒ Teach the start point far enough from the end point so the final end point can be
defined.
_____________________________________________________________________
ERROR CODE E1047
Axis number is not for conveyor follow mode.
Main causes include:
1. Setting the conveyor to the same axis number that is assigned to the traverse axis.
2. Changing settings in a specific conveyor tracking mode while in conveyor follow
mode.
⇒ Set the correct axis number for the conveyor ais using the ZCVAXIS command.
⇒ Change to the conveyor tracking mode if the robot does have a traverse unit.
_____________________________________________________________________
ERROR CODE E1048
Offset data of zeroing is illegal value.
When robot data is loaded the default value of zeroing offset for all axes is 0.
⇒ Confirm the loaded data is correct.
_____________________________________________________________________
ERROR CODE E1049
Current position is out of specified area.
(Option)
Current values of the robot are not in the specified area at the start of repeat operation.
⇒ Set CHGMOVE to OFF.
⇒ Move the robot inside of the specified area in teach mode.
_____________________________________________________________________
August 9, 2005
1-85
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1050
Encoder and brake power off signal not dedicated.
A gun change is executed on a servo spot weld gun without setting [Encoder and brake
power (7)] dedicated signal in AUX 0602.
⇒ From AUX 0602 Dedicated output Signals, set the [Encoder and brake power (7)]
signal to dedicated and enter the signal number.
_____________________________________________________________________
ERROR CODE E1051
Incorrect double OX output.
When double type signals are used, if either output in the pair is turned ON, the other
turns OFF. An instruction to turn both outputs ON, or turn both outputs OFF (OX=1,2 or
OX=-1,-2), causes this error.
⇒ Change the OX signal setting.
⇒ Modify program data.
_____________________________________________________________________
ERROR CODE E1052
Work sensing signal is not dedicated.
(sensing function)
This error occurs when the X-linear step is executed and the dedicated work sensing
signal is not detected. When the sensing function is used, a dedicated work sensing
signal must be set in AUX 1103.
⇒ Ensure the work sensing dedicated signal is set properly.
_____________________________________________________________________
ERROR CODE E1053
Work sensing signal already input.
(sensing function)
Main causes include:
1. The X-linear step is executed and the work sensing signal is already on.
2. The sensing start-point is too close to the workpiece.
3. The sensing device or sensing device harness fails.
⇒ Reteach the start point further away from the workpiece.
⇒ Repair or replace sensing device or sensing device harness.
_____________________________________________________________________
1-86
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1054
Cannot execute motion instruction.
Main causes include:
1. A motion instruction is executed for the slave robot during cooperative motion.
2. A motion instruction is executed in soft absorber mode (from SASTART to SAEND).
⇒ Correct the slave robot program. Only non-motion instructions can be used for the
slave robot in the cooperative motion program.
⇒ Do not use program motion instructions while in soft absorber mode. Only motion
instructions specific to the soft absorber function can be used in soft absorber mode.
_____________________________________________________________________
ERROR CODE E1055
Start point position error for circle.
The robot is stopped after it began executing a circular motion and moved 4 mm or more
away from its calculated path (jogging or brake slippage, etc.). Attempting to continue
execution of the path from this position results in this error.
⇒ Move the robot closer to the calculated path or restart the program a step prior to the
circular path.
_____________________________________________________________________
ERROR CODE E1056
MASTER robot already exists.
This error occurs when MASTER instructions are executed for both robots during coop-
erative motion.
⇒ One robot must be configured as the MASTER robot and the other robot must be
configured as the SLAVE robot.
_____________________________________________________________________
ERROR CODE E1057
Check to which robot MASTER/ALONE were instructed.
This error occurs when a robot other than the MASTER robot executes the ALONE,
MJMOVE, or MLMOVE instructions.
⇒ Make program corrections as required.
_____________________________________________________________________
August 9, 2005
1-87
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1058
SLAVE robot already exists.
This error occurs when SLAVE instructions are executed for both connected robots
during cooperative motion in repeat mode.
⇒ Do not execute SLAVE instructions for both robots at the same time.
_____________________________________________________________________
ERROR CODE E1059
Not an instruction for cooperative motion.
This error occurs when attempting to execute a non-cooperative motion instruction in
the MASTER robot program during cooperative motion.
⇒ Ensure only cooperative motion instructions are used in the MASTER robot program
during cooperative motion.
_____________________________________________________________________
ERROR CODE E1060
Cannot execute in check back mode.
The program reached an instruction which cannot be executed in check back mode.
Example:
Executing SHIFT instructions in reverse order results in a different path and cannot be
done.
⇒ Execute after selecting a step that can be checked backward. If possible, check
forward.
_____________________________________________________________________
ERROR CODE E1061
Cannot execute in ONE program.
A motion instruction is specified in the ONE program.
⇒ Do not program motion instructions in the ONE program.
⇒ Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
_____________________________________________________________________
ERROR CODE E1062
JT2 and JT3 interfere during motion to start pose.
Movement from the current position to the start pose would cause JT2 and JT3 to move
beyond their limits.
⇒ Modify the position of the start pose of the program.
_____________________________________________________________________
1-88
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1063
JT2 and JT3 interfere during motion to end pose.
Movement from the current position to the end pose would cause JT2 and JT3 to move
beyond their limits.
⇒ Modify the position of the end pose of the program.
_____________________________________________________________________
ERROR CODE E1064
Illegal pallet number.
This error occurs when a pallet number other than 1-9 is used with the PALUP instruc-
tion, or the PALLET function.
⇒ Ensure pallet number 1–9 is used.
_____________________________________________________________________
ERROR CODE E1065
Illegal material number.
This error occurs when the work (part) number in a block step program instruction or the
pallet function is other than 1–999.
⇒ Ensure the work number is 1–999.
_____________________________________________________________________
ERROR CODE E1066
Illegal pattern number.
Main causes include:
1. Program step does not comply with AS Language syntax.
2. Pattern number for work specified, using block step instructions or the PALLET func-
tion, is not between 1 and 5.
⇒ Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
⇒ Ensure the work pattern number specified is correct.
_____________________________________________________________________
August 9, 2005
1-89
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1067
Illegal pattern type.
Main causes include:
1. Program step does not comply with AS Language syntax.
2. Pattern type for work specified using block step instructions or the PALLET function is
not between 1 and 5.
⇒ Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
⇒ Ensure the work pattern number specified is correct.
_____________________________________________________________________
ERROR CODE E1068
Illegal work data.
Main causes include:
1. Program step does not comply with AS Language syntax.
2. Work data specified using block step instructions or the PALLET function is incorrect
or not registered.
⇒ Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
⇒ Ensure the work data specified is correct.
_____________________________________________________________________
ERROR CODE E1069
Illegal pallet data.
Main caused include:
1. Program step does not comply with AS Language syntax.
2. Pallet data in a block step program, the PALUP instruction or the PALLET function, is
incorrect or not registered.
⇒ Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
⇒ Ensure the pallet data specified is correct.
_____________________________________________________________________
ERROR CODE E1070
ON/ONI signal is already input.
An ON/ONI instruction mode “/ERR” is specified and the signal condition to monitor is
already attained when monitoring starts.
⇒ Delete the “/ERR” mode from the ON/ONI instruction or specify “/LVL” mode.
⇒ Modify the program so the signal condition is not attained until monitoring starts.
_____________________________________________________________________
1-90
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1071
XMOVE signal is already input.
An XMOVE instruction mode “/ERR” is specified and the signal condition to monitor is
already attained when monitoring starts.
⇒ Delete the “/ERR” mode from the XMOVE instruction or specify “/LVL” mode.
⇒ Modify the program so the signal condition is not attained until monitoring starts.
_____________________________________________________________________
ERROR CODE E1072
Home position data is not defined.
This error occurs when the home position data in AUX 0402 is set to all zeros and the
HOME command is executed.
⇒ Ensure the data for home position is other than all zeros in AUX 0402.
⇒ If a home position of all zeros is required, set the ZCHECKHOME switch to OFF.
_____________________________________________________________________
ERROR CODE E1073
Illegal timer number.
Displayed when a timer is specified other than 1–10.
⇒ Specify timers 1–10.
_____________________________________________________________________
ERROR CODE E1074
Over maximum signal number.
When the RUNMASK, SIGNAL, BITS, PULSE, or SWAIT commands are used with a
signal number that exceeds the range permitted by system configuration, this error is
displayed.
⇒ Check signal number specified in instruction and ensure it is within system configura-
tion.
_____________________________________________________________________
ERROR CODE E1075
Illegal clamp number.
Displayed when the clamp number entered exceeds the maximum permitted by system
configuration.
⇒ Use only clamp numbers that are supported by system configuration.
_____________________________________________________________________
August 9, 2005
1-91
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1076
Cannot use negative time value.
Displayed when a negative number is entered as part of a DELAY or TIMER command.
⇒ Correct the time setting to a positive number.
_____________________________________________________________________
ERROR CODE E1077
No value set.
Occurs when an instruction like the BITS command is evaluated and there is no corre-
sponding value set.
⇒ Correct program code to evaluate existing values.
_____________________________________________________________________
ERROR CODE E1078
Illegal signal number.
This error is displayed when the RUNMASK, SIGNAL, BITS, PULSE, or SWAIT com-
mands are used with a signal number that exceeds the range permitted by system
configuration.
⇒ Check signal number specified in the instruction and ensure it is within system con-
figuration.
_____________________________________________________________________
ERROR CODE E1079
Cannot use dedicated signal.
Occurs when a previously dedicated signal is used as a general purpose signal.
⇒ Use signals that have not been dedicated for specific functions.
_____________________________________________________________________
ERROR CODE E1080
Not RPS mode.
Main causes include:
1. External program reset signal is received, but RPS ON signal, or external program
input signal is not dedicated.
2. JUMP is taught in a block step program, but external program input signal is not
dedicated.
3. END is taught in a block step program, but the RPS ON signal is not dedicated.
4. EXTCALL is executed, but the signal for external program input is not dedicated.
⇒ Correct the program data.
⇒ If RPS is to be used the necessary signals must be dedicated.
_____________________________________________________________________
1-92
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1081
Cannot use negative value.
Displayed when a negative number is used in conjunction with the PULSE or
ACCURACY commands/instructions.
⇒ Use only positive numbers in the acceptable range for the PULSE and ACCURACY
commands/instructions.
_____________________________________________________________________
ERROR CODE E1082
Out of absolute lower motion range limit.
Displayed when an attempt is made to set the software lower limits of robot travel to a
value that is beyond the robots lower limit (LLIMIT command).
⇒ Set lower software travel limits to an acceptable value.
_____________________________________________________________________
ERROR CODE E1083
Out of absolute upper motion range limit.
Displayed when an attempt is made to set the software upper limits of robot travel to a
value that is beyond the robots upper limit (ULIMIT command).
⇒ Set upper software travel limits to an acceptable value.
_____________________________________________________________________
ERROR CODE E1084
Out of set lower motion range limit.
Data used is beyond the lower limit set in AUX 0507.
Example:
Data used for the SETHOME command is beyond the lower limit set in AUX 0507.
⇒ Set motion range within the motion range limits set in AUX 0507.
⇒ Set lower software travel limits to an acceptable range (confirm safe operation).
_____________________________________________________________________
ERROR CODE E1085
Out of user upper limit.
Data used is beyond the upper limit set in AUX 0507.
Example:
Data used for the SETHOME command is beyond the upper limit set in AUX 0507.
⇒ Set motion range within the motion range limits set in AUX 0507.
⇒ Set upper software travel limits to an acceptable range (confirm safe operation).
_____________________________________________________________________
August 9, 2005
1-93
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1086
Start point for Jt XX beyond motion range.
Robot pose at motion start is beyond the range set in AUX 0507.
Example:
DO HOME is executed at a point that is out of motion range set in AUX 0507.
⇒ Correct pose to within working envelope or expand software limits to accept pose.
_____________________________________________________________________
ERROR CODE E1087
End location point for Jt XX beyond motion range.
Main causes include:
1. Jt XX at a taught point is beyond the motion range set in AUX 0507.
2. With a servo spot weld gun installed, if a taught point is near the motion range limit
for an axis, the robot motion that results from performing tip wear compensation in
repeat/check mode causes the robot to exceed the motion range limit.
3. Taught data for the gun axis is out of motion range.
Example:
Taught data is changed from a gun released to a gun connected state without any
corresponding change in pose data.
⇒ Correct pose to within motion range or expand software limits in AUX 0507 to accept
pose.
⇒ Correct the correct data so that the robot motion is within motion range with the gun
connected.
_____________________________________________________________________
ERROR CODE E1088
Destination is out of motion range.
While executing a motion to a step, the software calculated the pose destination of all
joints to be outside of the allowable upper or lower software limits.
⇒ Correct pose to within motion range or expand software limits to accept pose.
_____________________________________________________________________
ERROR CODE E1089
Cannot do linear motion in current configuration.
System software determined that the start and end points of a linear or circular move
will cause the robot to exceed the acceptable motion parameters.
⇒ Change motion interpolation to a joint move; move the pose to avoid configuration
conflict.
_____________________________________________________________________
1-94
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1090
External modulation data is not input.
(Option)
External modulation data is not received.
⇒ Check for abnormality in the external modulation data line and repair as necessary.
_____________________________________________________________________
ERROR CODE E1091
External modulation data is abnormal.
(Option)
Modulation data is too large.
⇒ Check for abnormality in the external modulation data line and repair as necessary.
_____________________________________________________________________
ERROR CODE E1092
Modulation data is over limit.
(Option)
Modulation data exceeds the set allowable capacity.
⇒ Check for abnormality in the external modulation data line and repair as necessary.
_____________________________________________________________________
ERROR CODE E1093
Incorrect motion instruction to execute modulate motion.
(Option)
A non-modulation instruction is specified.
⇒ Specify appropriate modulation instruction.
_____________________________________________________________________
ERROR CODE E1094
Illegal joint number.
Occurs when the DRIVE or other similar command is used and a joint number is speci-
fied that is not part of the robot configuration.
⇒ Confirm robot configuration before using the DRIVE or other similar command.
_____________________________________________________________________
August 9, 2005
1-95
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1095
Cannot execute motion instruction in PC program.
A PC program cannot contain instructions that initiate robot motion.
⇒ Correct the PC program by removing motion instructions.
_____________________________________________________________________
ERROR CODE E1096
Incorrect auxiliary data settings.
The value selected for auxiliary data (speed, timer, tool etc.) exceeds allowable range.
⇒ Correct the value of auxiliary data.
⇒ Perform system initialization.
⇒ If correct value is entered and this error recurs, contact KRI customer service.
_____________________________________________________________________
ERROR CODE E1097
Missing C1MOVE or C2MOVE instruction.
Program circular motion instructions must have a C1MOVE followed by either a
C1MOVE or C2MOVE and end with a C2MOVE.
⇒ Correct program instructions.
_____________________________________________________________________
ERROR CODE E1098
C1MOVE (CIR1) instruction required before C2MOVE.
Program circular motion instructions must have C2MOVE move preceded by a
C1MOVE.
⇒ Correct program instructions.
_____________________________________________________________________
ERROR CODE E1099
Unable to create arc path, check positions of the 3 points.
Circular interpolation moves cannot be processed because the points identified are too
close together or are on a straight path.
⇒ Correct program instructions.
_____________________________________________________________________
1-96
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1100
Cannot execute in sealing specification.
Occurs when a CLOSE(I), OPEN(I), or RELAX(I) command is executed in a program
and clamp specifications in AUX 0605-1 are set for sealing.
⇒ Correct program instructions to match software configuration.
_____________________________________________________________________
ERROR CODE E1101
Can only execute in sealing specification.
Occurs when a GUNON, GUNOFF, GUNONTIME or GUNOFFTIME command is ex-
ecuted in a program and clamp specifications in AUX 0605-1 are not set for sealing.
⇒ Correct program instructions to match software configuration.
_____________________________________________________________________
ERROR CODE E1102
Option is not set, cannot execute.
(Option)
A command/instruction is executed for an option that is not installed and/or set up.
Example:
An attempt to save/load data to/from a floppy disk is made, but a floppy disk drive is not
installed and/or set up.
⇒ Ensure the option is installed and software is set up properly.
⇒ To install an option that is not included in the original controller specifications contact
KRI customer service.
_____________________________________________________________________
ERROR CODE E1103
Over conveyor position
(Option)
The value of the conveyor axis exceeds the set motion area limit.
⇒ Set the conveyor axis value to a value less than the maximum value.
_____________________________________________________________________
ERROR CODE E1104
Too many SPINMOVE instructions.
This error occurs when the SPINMOVE instruction is used in 17 or more consecutive
steps.
⇒ Correct the SPINMOVE program instruction to 16 or less consecutive steps in the
program between spin start and spin stop.
_____________________________________________________________________
August 9, 2005
1-97
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1106
Cannot execute in this robot.
This error occurs when a request is executed on a robot arm that does not support the
function.
⇒ Contact KRI customer service to have the function installed or delete the request.
_____________________________________________________________________
ERROR CODE E1108
Duplicate robot network IDs.
With the robot network installed and operational, the same ID number is assigned to two
different robots connected to the network.
⇒ Change the robot ID using the ROBNETID command.
_____________________________________________________________________
ERROR CODE E1109
Conveyor I/F board is not installed.
1JS board is not installed for interface with an incremental-type conveyor encoder.
1. 1JS board not installed to the 1GW/1HW board.
2. Defective 1JS board.
3. The 1JS board is installed onto a defective 1GW/1HW board.
⇒ Ensure the 1JS board is properly installed.
⇒ Replace the 1JS board.
⇒ Replace the 1JS board and the 1GW/1HW board.
_____________________________________________________________________
ERROR CODE E1110
GROUP is not primed.
The GROUP instruction is not programmed before a motion instruction, with external
axis system.
⇒ This error occurs if the program is interrupted after a GROUP instruction and before
the motion commands pertaining to the GROUP instruction are complete. When
restarting the program prime the program before the GROUP instruction.
⇒ In check mode, if the GROUP instruction is used, start checking before the GROUP
instruction.
_____________________________________________________________________
1-98
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1113
Work sensing signal is not detected.
(sensing function)
This error occurs when the X-linear step is executed and the workpiece is not detected
before the robot axes reach coincidence of the taught point.
The sensing device or sensing device harness may be defective.
⇒ Set the accuracy range to a smaller value.
⇒ Repair or replace sensing device or sensing device harness.
_____________________________________________________________________
ERROR CODE E1114
Interruption in cooperative control.
This error occurs when an error condition is generated for one robot during cooperative
motion in repeat mode operation.
⇒ Repair the cause of the interruption and reset the error.
_____________________________________________________________________
ERROR CODE E1115
Force termination of cooperative control.
The program ended without executing the ALONE instruction in either the MASTER or
the SLAVE robot program. Both robots are stopped and cooperative motion is released.
⇒ Insert the ALONE instruction in either the MASTER or the SLAVE robot program.
_____________________________________________________________________
ERROR CODE E1116
Spin axis is not stopped on every 360 degrees.
During spin, the robot or spin axis is stopped and the current pose is taught with the JT6
spin axis stopped at a position other than 0 degrees.
Main causes include:
1. EMERGENCY STOP switch is pressed.
2. HOLD/RUN switch is set to HOLD.
3. TEACH/REPEAT switch is set to TEACH.
⇒ Execute SPINRESET to correct the rotation angle of the JT6 spin axis to stop in 360
degree units.
_____________________________________________________________________
August 9, 2005
1-99
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1117
Process time over.
Lack of system processing time
⇒ Contact KRI customer service (include operating conditions/settings and operation
log at the time the error occurred).
_____________________________________________________________________
ERROR CODE E1118
Command value for Jt XX suddenly changed.
Spot Welding and Material Handling
In the repeat mode, the commanded position of the joint identified exceeds the limit
value. In the check mode, the commanded position of the joint identified exceeds the
speed limit value.
⇒ Check for singularity condition during robot motion and reteach to correct.
⇒ Check for loose or defective servo system encoders, harnesses, and circuit boards.
⇒ Replace 1KB board.
⇒ Replace power block.
Servo Spot Weld Gun
Occurs when corrections for deflection cause movement of the robot to exceed the
range of motion of one or more axes. This condition is not limited to the gun axis; any
axis, including the gun axis, can cause this error.
⇒ Change the posture of the robot.
⇒ Decrease the speed in the step.
⇒ Reduce the amount of the deflection correction in the step by using AS Language
SGREFLEX command (check conditions during pressurizing).
⇒ Reteach the point and change the configuration of the posture of the robot if needed.
_____________________________________________________________________
1-100
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1119
Commanded value for Jt XX beyond motion range.
Spot Welding and Material Handling
The commanded position for the joint identified exceeds the software limits. Condition is
monitored in both the check and repeat modes.
⇒ Correct taught positions to avoid the software limits.
⇒ Adjust the software limits in AUX 0507 to provide the necessary motion range.
Servo Spot Weld Gun
If a taught point is near a servo gun or arm axis range of motion limit, the combination of
tip wear and deflection correction can prevent the robot from reaching the taught point.
⇒ Do not teach points that are near axes range of motion limits.
_____________________________________________________________________
ERROR CODE E1120
Current command causes interference betw Jt2 and Jt3.
A posture is attempted which causes Jt2 and Jt3 to interfere with each other.
⇒ Change the taught poses.
_____________________________________________________________________
ERROR CODE E1121
Other robot is in the interference area.
This error occurs when the zone interference signal is not received.
⇒ Ensure the zone interference signal is set-up correctly and the program is written
correctly.
_____________________________________________________________________
August 9, 2005
1-101
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1122
Unexpected motor power OFF.
Occurs when software turns motor power ON (K1 or K2 contactors ON) but there is no
signal feedback (MCON) indicating motor power is ON.
Main causes include:
1. Defect in the 1KP power sequence board.
2. Defect in the 1KQ/1NQ relay board.
3. Malfunction in the error detection circuit and error processing of 1KP/1KQ board.
4. Auxiliary contact of magnet contactor (K1, K2) for motor power is defective.
5. Malfunction with the servo software or the AS software.
6. Defect in the harnesses between 1KQ-CN3 and KI/K2.
⇒ Reinstall AS/servo software.
⇒ Replace the 1KP power sequence board.
⇒ Replace the 1KQ/1NQ relay board.
⇒ Replace the magnetic contactor (K1, K2).
⇒ Repair or replace the harnesses between 1KQ-CN3 and K1/K2.
⇒ Replace the MC unit.
_____________________________________________________________________
ERROR CODE E1123
Speed error Jt XX.
Joint speed (motor speed) calculated using encoder values exceeds the rated value.
Main causes include:
1. Disconnected motor power line U, V, and/or W phase, or defective power block.
2. Wiring error in motor power line and/or encoder line.
3. Disconnected encoder signal line, short circuit in encoder or encoder wiring, and/or
defective main body of the encoder.
4. Robot motion program causes a singularity.
5. Defective 1KB servo board and/or power block.
6. Moment of inertia exceeded the motor torque.
⇒ Reduce payload to the specified ratings.
⇒ Check for disconnection, short circuit, and proper wiring for the U, V, and W motor
power line.
⇒ Replace the encoder and/or encoder harness as necessary.
⇒ Replace the 1KB board.
⇒ Replace the power block.
⇒ Rewrite program data such as speed and pose in the case of singularity motion.
_____________________________________________________________________
1-102
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1124
Deviation error of Jt XX.
Spot Welding and Material Handling
The difference between the current value from the encoder and the command value in
the AS software exceeds the regulated value (varies by robot model).
Main causes include or the following abnormalities:
Mechanical -
1. Singularity motion.
2. The robot arm has contacted an external item hindering movement.
3. The harness is caught in the robot arm.
4. The cyclo reduction unit, the gear, or the bearing are damaged.
5. Cyclo reduction unit gear backlash is too narrow.
6. Payload weight exceeds robot specifications for capacity.
7. Robot motion pattern exceeds ratings of the motor.
8. Motor brake is not released.
Electrical-
1. Motor power line U, V, and W phase are disconnected.
2. The brake line is disconnected or brake drive circuit is damaged.
3. Defective 1KQ/1NR board.
4. The power block is damaged.
5. Defective 1KB servo board.
6. Malfunction of the motor.
⇒ Check the cyclo reduction unit, etc. for mechanical failure. Replace as necessary.
⇒ Re-teach robot motion as necessary.
⇒ Check the harnesses and power block unit for electrical malfunctions and replace as
necessary.
⇒ Replace the 1KB board.
⇒ Replace the 1KQ/1NR board.
⇒ Correct the teach data in case of singularity motion.
Servo Spot Weld Gun
The thickness of the workpiece at the weld point is greater than the thickness when the
point is taught. The thickness difference required to set this error is approximately 10
mm, depending on the gun type.
⇒ Inspect the workpiece; replace it if necessary.
_____________________________________________________________________
August 9, 2005
1-103
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1126
Commanded speed error Jt XX.
This error occurs when the positional command value sent to the 1KB board from the
1KA board exceeds the value range.
Main causes include:
1. A sudden change in robot motion.
2. Defective 1KA/1KB board.
3. Corrupt AS software caused the commanded speed value to exceed motor capacity
rating.
⇒ Modify program data to eliminate sudden changes in robot motion.
⇒ Replace the 1KB board.
⇒ Replace the 1KA board.
⇒ Replace the 1KX board (motherboard).
⇒ Reload software for the 1KB board and/or 1KA board.
_____________________________________________________________________
ERROR CODE E1127
Command acceleration error Jt XX.
This error occurs when the amount of change in the speed value, sent to the 1KB board
from the 1KA board, exceeds the value range.
Main causes include:
1. Sudden change in robot motion.
2. Defective 1KA/1KB board.
3. Corrupt AS software caused the commanded acceleration value to exceed motor
capacity rating.
⇒ Modify program data to eliminate sudden changes in robot motion.
⇒ Replace the 1KB board.
⇒ Replace the 1KA board.
⇒ Replace the 1KX board (motherboard).
⇒ Reload software for the 1KB board and/or 1KA board.
_____________________________________________________________________
1-104
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1128
Uncoincidence error betw destination and current Jt XX
pos.
This error occurs during program execution, if all joints do not reach total coincidence
within the commanded accuracy and time.
Main causes include.
Mechanical-
1. Damaged bearings.
2. Insufficient gear backlash.
3. Motor brake not released.
4. Arm movement restricted by harnesses or peripheral devices.
Electrical-
1. Motor power line U, V, and W phase are disconnected.
2. Defective 1KB servo board.
3. Defective 1KQ/1NR board (malfunction in the brake circuit).
3. Defective power block.
4. Disconnected motor power or brake lines.
5. Defective encoder or encoder harness.
Program data-
1. The difference in the angle of the wrist at the start and end steps is too great.
Example: 180 degrees at the start step and -180 degrees at the end step.
⇒ Repair mechanical or electrical failures as necessary.
⇒ Check interference from external devices.
⇒ Modify taught wrist positions as required.
_____________________________________________________________________
ERROR CODE E1129
Jt XX is moved during regulation of external axis.
(External axis restriction function)
This error occurs when an attempt is made to move the robot in teach or repeat mode
while the external axis restriction signal is present.
⇒ Ensure the internal interlock circuit is operating normally.
⇒ Ensure the robot program is written correctly.
_____________________________________________________________________
August 9, 2005
1-105
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1130
Jt XX collision was detected.
Motor current command value exceeds the threshold value set in AUX 0510.
⇒ Remove obstacles in the robot motion path area.
⇒ Ensure tool settings are correct.
⇒ If an obstacle was not encountered, increase the threshold value set in AUX 0510.
_____________________________________________________________________
ERROR CODE E1131
Jt XX Unexpected shock is detected.
Change in motor current command value, per unit of time, exceeds the threshold value
set in AUX 0510.
⇒ Remove obstacles in the robot motion path area.
⇒ Ensure tool settings are correct.
⇒ If an obstacle was not encountered, increase the threshold value set in AUX 0510.
_____________________________________________________________________
ERROR CODE E1132
Motor power OFF. Measurement stopped.
This error occurs when motor power is interrupted during auto load measurement.
Main causes include:
1. External HOLD/RUN switch is set to HOLD.
2. TEACH/REPEAT switch is set to TEACH.
3. External EMERGENCY STOP switch is pressed.
⇒ Reset switches to allow repeat operation. Repeat the auto load measurement.
⇒ Ensure the motor power is not interrupted during auto load measurement. Repeat
the auto load measurement.
_____________________________________________________________________
ERROR CODE E1133
Conveyor has reached max. value position.
The conveyor exceeded the maximum value set for the conveyor during program execu-
tion.
⇒ Ensure conveyor maximum value is set correctly.
⇒ Modify program data as necessary.
_____________________________________________________________________
1-106
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1134
Abnormal work transfer pitch.
The signal for resetting the conveyor value is received before the conveyor reached the
position specified by the work transfer pitch.
⇒ Ensure the work transfer pitch is set correctly.
⇒ Modify program data as necessary.
_____________________________________________________________________
ERROR CODE E1135
Motor power OFF.
Displayed whenever an emergency stop is encountered.
Main causes include:
1. External EMERGENCY STOP switch is pressed.
2. Teach pendant or operation panel EMERGENCY STOP switch is pressed.
3. Emergency stop line is disconnected.
⇒ Reset emergency stop button and reapply motor power.
⇒ Repair emergency stop line as necessary.
_____________________________________________________________________
ERROR CODE E1136
Standard terminal is not connected.
A PRINT, TYPE, or PROMPT command is specified for display on a PC that is not
connected.
⇒ Verify the PC connections and set-up, or modify, the commands for display on the
teach pendant.
_____________________________________________________________________
ERROR CODE E1137
Cannot input/output to teach pendant.
Main causes include:
1. A PRINT, TYPE, or PROMPT command is specified for display on the teach pendant,
and a teach pendant connection is not present.
2. Incorrect setting for teach pendant connection.
3. Controller is unable to switch to the teach pendant keyboard screen in its current
state.
⇒ Verify the teach pendant connections and set-up, or modify, the commands for display
on the PC.
⇒ Reset the teach pendant so switching to the keyboard screen is possible.
_____________________________________________________________________
August 9, 2005
1-107
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1138
Aux. terminal is not connected.
External monitoring device is not connected.
⇒ Ensure the external monitoring device is properly connected.
_____________________________________________________________________
ERROR CODE E1139
DA board is not installed.
(Option, analog voltage output)
Main causes include:
1. The optional I/O board for analog output is not installed or is defective (1GW/1HW
with analog output option).
2. The signal number used is not in the range of usable signal numbers set using the
SETOUTSIG command/instruction.
⇒ Install or replace the optional I/O board for analog output (1GW/1HW with analog
output option).
⇒ Ensure the signal number used is in the range of usable signal numbers set using the
SETOUTSIG command/instruction.
_____________________________________________________________________
ERROR CODE E1140
There is no conveyor axis.
Conveyor synchronous function is set-up but a conveyor axis is not installed.
⇒ Change the settings or install the conveyor axis.
_____________________________________________________________________
ERROR CODE E1141
Conveyor transfers beyond sync. zone.
During synchronous motion the conveyor transferred beyond the synchronous zone set
using the CVWAIT instruction.
⇒ Ensure the synchronous zone set using the CVWAIT instruction is correct.
_____________________________________________________________________
ERROR CODE E1142
No traverse axis.
Conveyor follow mode is set-up but a traverse axis is not installed.
⇒ Ensure conveyor tracking mode is properly set-up.
⇒ Install a traverse axis.
_____________________________________________________________________
1-108
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1143
Conveyor axis number is not set.
Conveyor axis number is not set at execution of conveyor synchronous motion.
⇒ Set the conveyor axis number using the ZCVAXIS instruction.
_____________________________________________________________________
ERROR CODE E1144
No arm control board.
⇒ Ensure the 1KB arm control board is properly installed.
⇒ Replace the 1KB board.
⇒ Replace the 1KA board.
_____________________________________________________________________
ERROR CODE E1145
Cannot use specified channel, already in use.
Several “WHERE” commands were executed at the same time.
⇒ Do not execute unnecessary “WHERE” commands.
_____________________________________________________________________
ERROR CODE E1146
[LESQ] Aborted by process time over.
KLogic program did not complete execution within the specified time.
⇒ Contact KRI customer service (include operating conditions/settings and operation
log at the time the error occurred).
_____________________________________________________________________
ERROR CODE E1147
Cannot open setting file, so cannot set to shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, there is no
setting file (ini_load.cmd) in the 1KA board memory.
⇒ Load the setting file (ini_load.cmd) into the 1KA board memory.
_____________________________________________________________________
ERROR CODE E1148
Cannot read setting file, so cannot set to shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, the setting
file (ini_load.cmd) in the 1KA board memory could not be decoded.
⇒ Ensure the proper setting file (ini_load.cmd) is loaded into the 1KA board memory.
_____________________________________________________________________
August 9, 2005
1-109
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1149
Cannot open setting data, so cannot set to shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, a data file
in the setting file (ini_load.cmd) in the 1KA board memory could not be opened.
⇒ Ensure the proper setting file (ini_load.cmd) is loaded into the 1KA board memory.
_____________________________________________________________________
ERROR CODE E1150
Cannot read setting data, so cannot set to shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, a data file
in the setting file (ini_load.cmd) in the 1KA board memory could not be decoded.
⇒ Ensure the proper setting file (ini_load.cmd) is loaded into the 1KA board memory.
⇒ If the proper setting file (ini_load.cmd) is loaded replace the 1KA board.
_____________________________________________________________________
ERROR CODE E1151
Too much data for setting to the shipment state.
When “2: Setting to shipment state” is selected from the initialization screen, more than
10 data files are in the setting file (ini_load.cmd) in the 1KA board memory.
⇒ Ensure 10 or less data files are in the setting file (ini_load.cmd) loaded into the 1KA
board memory.
_____________________________________________________________________
ERROR CODE E1152
Name of setting data for shipment state is too long.
When “2: Setting to shipment state” is selected from the initialization screen, the name
of a data file in the setting file (ini_load.cmd) in the 1KA board memory exceeds eight
characters, or the file extension exceeds four characters.
⇒ Ensure the file name and extension contains the proper number of characters.
_____________________________________________________________________
ERROR CODE E1153
Power sequence board detects error. (Code=XX)
An error is detected by the 1KP board but the code (Code=XX) could not be interpreted
by the AS software.
⇒ Replace the 1KP board.
⇒ If this error recurs after replacing the 1KP board contact KRI customer service.
_____________________________________________________________________
1-110
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1154
Option SIO port is not installed.
Main causes include:
1. Optional communication port (1GS board) is not installed to the 1KA board.
2. Optional communication port (1GS board) is not recognized by the 1KA board.
⇒ Install the optional communication port (1GS board) onto the 1KA board.
⇒ Replace the 1KA board.
_____________________________________________________________________
ERROR CODE E1155
A/D converter is not installed.
A/D converter board (1FH) is not installed to the 1KA board.
⇒ Install the A/D converter board (1FH).
_____________________________________________________________________
ERROR CODE E1156
[ARM CONTROL BOARD] Processing time over.
AS software processing did not complete within normal time.
⇒ Reset the error.
⇒ If this error recurs, contact KRI customer service.
_____________________________________________________________________
August 9, 2005
1-111
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1157
Arm ID I/F board error. (code XXX)
Code
C1H
C5H
C6H
FFH
Description
Communication check sum error1
Communication protocol error1
Communication response time-out error1
Other errors (unknown error)2
1Damaged or disconnected communication cable.
2F*H cycle controller power ON and OFF. If error does not clear
further diagnosis is needed (possible damaged arm ID board
or power sequence board).
Main causes include:
1. Defective 1GV/1KA/1KB/1KP boards.
2. Defective controller harness, separate harness, and/or machine harness.
⇒ Replace 1GV/1KA/1KB/1KP boards.
⇒ Replace controller harness, separate harness, and/or machine harness.
_____________________________________________________________________
ERROR CODE E1158
(SSCNET) Servo error of Jt XX.
Alarm or warning detected in the Mitsubishi servo amplifier or servo motor.
⇒ Refer to the message displayed after the error message.
_____________________________________________________________________
ERROR CODE E1159
(SSCNET) Error code for servo is (XX).
Alarm or warning detected in the Mitsubishi servo amplifier or servo motor.
⇒ Refer to the Mitsubishi servo amplifier instruction manual for troubleshooting.
_____________________________________________________________________
ERROR CODE E1160
(SSCNET) Servo error and monitor setting error of Jt XX.
Alarm or warning detected in the Mitsubishi servo amplifier or servo motor, but alarm
and warning is not set to be monitored and displayed.
⇒ Set the alarm and warning to be monitored, and refer to the messaged displayed for
troubleshooting.
_____________________________________________________________________
1-112
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1162
Buffer overflow occurred gravity comp. value channel XX.
Gravity compensation value overflow due to mismatch of load weight and the set value.
⇒ Contact KRI customer service (include operating conditions/settings and operation
log at the time the error occurred).
_____________________________________________________________________
ERROR CODE E1163
Robot stopped in checking operational area.
The robot stopped during auto load measurement and is unable to continue the opera-
tion.
⇒ Repair the cause of the robot stopping and re-execute auto load measurement.
_____________________________________________________________________
ERROR CODE E1164
[LSEQ] Program execution error in at control power ON.
(code XX)
Controller power is set OFF during KLogic program execution and the program did not
re-execute automatically at the next controller power-up.
⇒ Display the contents of the error message number displayed after the code (sub-code
XX) using the $ERROR function.
Example: TYPE $ERROR (-11038)
_____________________________________________________________________
ERROR CODE E1165
Unable to download ext. axis parameter. (Jt-A)
Download failed due to channel 7 parameter being downloaded by another process.
⇒ Re-execute parameter download.
⇒ If this error recurs, contact KRI customer service.
_____________________________________________________________________
ERROR CODE E1166
Num. not assigned to specified channel. (Jt-A)
Channel is not assigned an axis number.
⇒ Assign an axis number to channel 7.
_____________________________________________________________________
August 9, 2005
1-113
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E1167
Unable to download ext. axis parameter. (Jt-B)
Download failed due to channel 8 parameter is being downloaded by another process.
⇒ Re-execute parameter download.
⇒ If this error recurs, contact KRI customer service.
_____________________________________________________________________
ERROR CODE E1168
Num. not assigned to specified channel. (Jt-B)
Channel is not assigned an axis number.
⇒ Assign an axis number to channel 8.
_____________________________________________________________________
ERROR CODE E1169
Error in servo parameter change sequence. (code XX)
Servo parameters upload/download requested but completion is not confirmed.
Code
A
Description
Unit number normally 0.
B
Channel number. 0 is the first channel on the 1KB board and is normally JT1.
Group number. Servo parameters are in two parts.
Sequence status
C
D
Initialize:0, normal:, 1 upload request: 2, waiting upload:3, download request:4,
waiting download:5, end process: 6.
F
⇒ Reset error.
⇒ If error cannot be reset, cycle controller power OFF and ON.
_____________________________________________________________________
1-114
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4000
Data communication error.
Main causes include:
1. When receiving data from vision sensor:
–Time out occurred, data is not received within the specified time.
–Robot is stopped by HOLD, ABORT or PCABORT during data communication.
–Robot stopped by the CONTROL key or ENTER key from a PC keyboard during
data communication
2. During Host Communication I, data is not received within the specified time after
ENQ code is sent.
3. Communication error occurred during PC terminal, floppy disk, or PC card interaction
with the AS software.
⇒ Check communication line, and re-execute.
⇒ Ensure communication protocol used for Host Communication I is correct.
⇒ Check the communication cable, and replace as necessary.
_____________________________________________________________________
ERROR CODE E4001
Data reading error.
Discrepency in data between when it is written to a PC terminal, floppy disk or PC card
and when it is read back from the storage media for verification.
⇒ Re-execute data reading.
⇒ If this error recurs, replace the storage media, 1KA/1KF boards, harness, etc.
_____________________________________________________________________
ERROR CODE E4002
Data transfer error.
Error occurred during data writing to a PC terminal, floppy disk or PC card.
⇒ Re-execute data writing.
⇒ If this error recurs, replace the storage media, 1KA/1KF boards, harness, etc.
_____________________________________________________________________
ERROR CODE E4003
Unexpected error in file access.
During floppy disk or PC card interaction with the AS software, an undefined communi-
cation error occurred.
⇒ Re-execute file access.
⇒ If this error recurs, replace the storage media, 1KA/1KF boards, harness, etc.
_____________________________________________________________________
August 9, 2005
1-115
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4004
Communication retry error.
Communication retry error during Host Communication I.
Main causes include:
1. No response after sending text.
2. After text is sent, NAK (resend request) exceeded the allowed number of retries.
⇒ Ensure communication protocol used for Host Communication I is correct.
⇒ Check the communication cable and replace as necessary.
_____________________________________________________________________
ERROR CODE E4005
Communication process was stopped.
During Host Communication I, a stop monitor command (ABORT, PCABORT, etc.) is
executed during execution of SEND/RECEIVE.
⇒ Re-execute the EXECUTE, PCEXECUTE, etc. command.
_____________________________________________________________________
ERROR CODE E4006
Receive no data after request.
During Host Communication I, text data is not received within the allowed time after the
data request is sent.
⇒ Ensure communication protocol used for Host Communication I is correct.
⇒ Check the communication cable and replace as necessary.
_____________________________________________________________________
ERROR CODE E4007
Receiving data is too long (MAX=255 character).
During Host Communication I, an attempt to receive a string with more than 255 charac-
ters is made.
⇒ Ensure communication protocol used for Host Communication I is correct.
_____________________________________________________________________
ERROR CODE E4008
Abnormal data (EOT) received in communication.
During Host Communication I, abnormal code (EOT) is received and the communication
process is stopped.
⇒ Ensure communication protocol used for Host Communication I is correct.
_____________________________________________________________________
1-116
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4009
Communication time out error.
During Host Communication I or TCP/IP interface, data is not received within the al-
lowed time after executing the RECEIVE instruction.
⇒ Ensure communication protocol used for Host Communication I is correct.
⇒ Reserve the communication line.
_____________________________________________________________________
ERROR CODE E4010
Terminal already in use.
The prompt instruction is executed by two or more programs at the same time.
⇒ Do not execute the prompt instruction from two or more programs at the same time.
_____________________________________________________________________
ERROR CODE E4011
Communication port already in use.
During Host Communication I, TERMON is executed from the teach pendant keyboard
screen while the PC terminal port is in use.
⇒ Ensure the PC terminal port is not in use before execution of TERMON from the
teach pendant keyboard screen.
_____________________________________________________________________
ERROR CODE E4012
Waiting for input of PROMPT. Connect input device.
The input device specified by a prompt command, i.e., PC or teach pendant, is not
connected.
⇒ Ensure the specified device is connected.
_____________________________________________________________________
ERROR CODE E4013
TELNET) SEND error. CODE=XX.
This error occurs when data is transmitted by TCP/IP, and an abnormality occurs in the
communication line or the connection is aborted or closed.
⇒ Check the communication line to the target end node and repair as necessary.
⇒ Check for problems at the target end node and repair as necessary.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
August 9, 2005
1-117
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4014
TELNET) RECV error. CODE=XX.
During TCP/IP communication, data is not received due to a RECV (receive) error.
⇒ Check the communication line to the target end node and repair as necessary.
⇒ Check for problems at the target end node and repair as necessary.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4015
TELNET) IAC receive error. CODE=XX.
During TCP/IP communication, an error occurred when receiving data.
⇒ Check the communication line to the target end node and repair as necessary.
⇒ Check for problems at the target end node and repair as necessary.
⇒ Ensure the PC at the target end is using KCWIN TCP software.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4016
TELNET) Close failure. CODE =XX.
An error occurred in the LISTEN/ACCEPT function during an attempt to close the
socket. TCP/IP resources (queue or buffer) may be full. May be a problem with the
communication line or at the target end node.
⇒ Stop any other TCP/IP functions operating at the same time.
⇒ Cycle robot controller power OFF and ON.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4017
TELNET) Main socket close failure. CODE=XX.
An error occurred in the LISTEN/ACCEPT function during an attempt to close the main
socket. TCP/IP resources (queue or buffer) may be full. May be a problem with the
communication line or at the target end node.
⇒ Stop any other TCP/IP functions operating at the same time.
⇒ Cycle robot controller power OFF and ON.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
1-118
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4018
TELNET) System error. CODE=XX.
Parameter settings entered using the NETCONF command does not comply with AS
Language syntax.
The code (CODE=xx) indicates a detailed SUB error code for the TCP/IP package.
⇒ Refer to the TCP/IP package manual.
⇒ Ensure the parameter settings are entered in compliance with AS Language syntax.
_____________________________________________________________________
ERROR CODE E4019
TCP/IP) Socket open failure. CODE=XX
Dst.IP=xx.xx.xx.xx.
This error occurs when execution of a socket open instruction (TCP_LISTEN/
TCP_CONNECT/UPD_SENDTO/UPD_RECVFROM) fails. If multiple socket numbers
are used, the number of sockets may exceed the limit. Possible IP address parameter
error.
⇒ Ensure during multiple socket openings do not exceed limits.
⇒ Ensure the IP address parameters are correct.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4020
TCP/IP) Socket close failure. CODE=XX
Dst.IP=xx.xx.xx.xx.
This error occurs when socket closing instruction (TCP_CLOSE/TCP_END_LISTEN/
UDP_SENDTO/UDP_RECVFREOM) fails. May be a problem with the communication
line or at the target end node.
⇒ Check the communication line to the target end node and repair as necessary.
⇒ Check for problems at the target end node and repair as necessary.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
August 9, 2005
1-119
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4021
TCP/IP) Communication Error. CODE=XX
Dst.IP=xx.xx.xx.xx.
A communication error occurred during execution of the UDP_SENDTO/
UDP_RECVFROM/TCP_SEND/TCP_RECV instruction. May be a problem with the
Ethernet line or at the target end.
⇒ Check the communication line to the target end node and repair as necessary.
⇒ Check for problems at the target end node and repair as necessary.
⇒ The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4022
TCP/IP) Message is too long.
Data sent exceeds the allowed size limit using the TCP_SEND/UDP_SENDTO/
UDP_RECVFROM instruction.
⇒ Edit the data to within allowed size limit (TCP: 4096 bytes or less, UPD: 1472 bytes or
less).
_____________________________________________________________________
ERROR CODE E4023
TCP/IP) Cannot reach the Host.
Failed to connect with the target end node when executing the UDP_SENDTO/
UDP_RECVFROM/TCP_CONNECT instruction. The host of the corresponding IP
address does not exist on the network. Designated port number or IP address may be
wrong. May be a problem with the communication line or at the target end node.
⇒ Ensure the port number and the IP address are correct.
⇒ Ensure the parameter settings comply with AS Language syntax.
⇒ Check the communication line to the target end node and repair as necessary.
_____________________________________________________________________
ERROR CODE E4024
TCP/IP) Communication Time Out.
Dst.IP=xx.xx.xx.xx.
Communication time-out occurred during instruction execution. May be a problem with
the Ethernet line or at the target end node.
⇒ Check the communication line to the target end node and repair as necessary.
_____________________________________________________________________
1-120
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4025
TCP/IP) Connection aborted.
Communication is disconnected during execution of the UDP_SENDTO/
UDP_RECVFROM/TCP_CONNECT/TCP_SEND/TCP_RECV/TCP_ACCEPT instruc-
tion. May be a problem with the Ethernet line or at the target end node.
⇒ Check the communication line to the target end node and repair as necessary.
_____________________________________________________________________
ERROR CODE E4026
TCP/IP) No Buffer Space.
A communication error occurred during execution of the UDP_SENDTO/
UDP_RECVFROM/TCP_SEND/TCP_RECV instruction. TCP/IP resources (queue or
buffer) may be full.
⇒ Stop any other TCP/IP functions operating at the same time.
⇒ Cycle robot controller power OFF and ON.
⇒ Check the communication line to the target end node and repair as necessary.
_____________________________________________________________________
ERROR CODE E4027
TCP/IP) Bad Socket.
Failed to connect with the target end node when executing the UDP_SENDTO/
UDP_RECVFROM/TCP_CONNECT instruction. Designated port number or IP address
may be wrong. May be a problem with the Ethernet line or at the target end node.
⇒ Ensure the port number and the IP address are correct.
⇒ Ensure the parameter settings comply with AS Language syntax.
⇒ Check the communication line to the target end node and repair as necessary.
_____________________________________________________________________
ERROR CODE E4028
FTP) Data receive error. (code=XX)
Failure to receive the teach data via LAN→Memory (Manual LOAD), or the LAN file
directory information list. May be a communication cable connection problem.
⇒ Ensure the communication cable connections are correct and re-execute.
_____________________________________________________________________
August 9, 2005
1-121
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4029
FTP) Data send error. (code=XX).
Failure to transmit the teach data via Memory→LAN (Manual SAVE). May be a commu-
nication cable connection problem.
⇒ Ensure the communication cable connections are correct and re-execute.
_____________________________________________________________________
ERROR CODE E4031
FTP) Failed to disconnect with FTP server. (code=XX)
Failure to terminate when completing communication with the FTP server.
Probable causes:
1. Communication cable is not properly connected.
2. The remote host FTP server is OFF or is in an abnormal condition.
⇒ Ensure the communication cable is properly connected and re-execute.
⇒ Reboot the remote host FTP server.
_____________________________________________________________________
ERROR CODE E4032
FTP) Unregistered OS detected.
An unregistered OS is detected.
⇒ Register the detected OS.
_____________________________________________________________________
ERROR CODE E4033
FTP) Failed to connect with server. (code=XX)
The connection failed when communication is started with the FTP server.
Main causes include:
1. The designated address does not exist on the network.
2. Communication cable is not properly connected.
3. Failed to login to FTP server.
⇒ Ensure the IP address is correct in Set Remote Host Information.
⇒ Ensure the communication cable is properly connected, and re-execute.
⇒ Ensure the user name and password for the LAN remote host save/load settings are
correct.
_____________________________________________________________________
1-122
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4034
FTP) failed to receive HOST OS information. (code=XX)
Error occurred during receiving OS information from the server.
⇒ Ensure the communication cable is properly connected, and re-execute.
⇒ Reboot the FTP server.
_____________________________________________________________________
ERROR CODE E4036
FTP) FTP service busy now.
A command is being executed by the server.
⇒ Allow the current command to complete execution, and re-execute.
⇒ If this error recurs contact KRI customer service.
_____________________________________________________________________
ERROR CODE E4037
FTP) Failed AUTO-SAVing.
An error occurred during auto save; an additional error code is displayed after the error
message.
⇒ Follow the procedures for the error displayed after the error message.
_____________________________________________________________________
ERROR CODE E4050
No response from the FDD/PC_CARD driver board.
A SAVE/LOAD etc. command is requested by the 1KA board, but no response is re-
ceived from the 1KF board.
⇒ Check harness and connections to the 1KF board and repair as necessary.
⇒ Replace the 1KA/1KF boards.
_____________________________________________________________________
ERROR CODE E4051
No communication with FDD/PC_CARD driver board.
No communication between the 1KA and 1KF boards.
⇒ Check harness and connections to the 1KF board and repair as necessary.
⇒ Replace the 1KA/1KF boards.
_____________________________________________________________________
August 9, 2005
1-123
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4052
[FDD/PC_CARD] Failed to set verify function. Please set
again.
Failure to set condition for verify function for the 1KF board.
⇒ Re-set condition for verify function in AUX 0208.
_____________________________________________________________________
ERROR CODE E4053
Channel error.
A monitor or program instruction is executed on an unavailable channel.
Example: Port number is not set within 8192–65535 for UPD_SENDTO.
⇒ Specify an available channel.
_____________________________________________________________________
ERROR CODE E4054
TCP/IP) Cannot execute because Ethernet board not
installed.
Main causes include:
1. 1KN board (daughter board on the 1KA board) is not installed.
2. Defective 1KN/1KA boards.
⇒ Ensure the 1KN board is properly installed.
⇒ Replace the 1KA/1KN boards.
_____________________________________________________________________
ERROR CODE E4055
TCP) Cannot create a socket.
Failure to open a socket when TCP_LISTEN/TCP_CONNECT is executed.
Main causes include:
1. Too many sockets open.
2. Same port is used too many times.
⇒ Close opened sockets using TCP_CLOSE and re-execute TCP_LISTEN/
TCP_CONNECT.
⇒ Avoid executing too many instructions at a time.
⇒ Ensure parameters are correct.
_____________________________________________________________________
1-124
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4056
TCP) This port is not in LISTEN (SOCK).
Main causes include:
1. Failure to open the socket when executing TCP_ACCEPT.
2. Failure to close the socket when executing TCP_END_LISTEN.
⇒ Ensure correct port number is used.
⇒ Ensure the parameter settings are entered in compliance with AS Language syntax.
_____________________________________________________________________
ERROR CODE E4057
TCP) Illegal Socket ID.
Communication error occurred when executing TCP_SEND/TCP_RECV, or failure to
close socket when executing TCP_CLOSE/TCP_END_LISTEN.
Main causes include:
1. The socket ID number or port number is not created.
2. Incorrect program execution order.
⇒ Ensure the correct socket ID number or port number is used.
⇒ Ensure the program execution order is correct
_____________________________________________________________________
ERROR CODE E4058
Failed download to FDD/PC_CARD driver board.
Failed to download software to the floppy disk driver board or the PC card driver board
(1KF board).
⇒ Ensure proper 1KF board software download settings are used.
⇒ It the error recurs, replace the 1KF board.
_____________________________________________________________________
ERROR CODE E4500
ANYBUS) IN-AREA request timeout. XX
Main causes include:
1. Error lamp ON:
Request for access to the output signal writing area is rejected due to hardware
abnormality.
2. Error lamp OFF:
Access to the output signal writing area is not released due to hardware abnormality.
⇒ Check LED indicator on the interface card, and reset the error.
⇒ If the error message is still displayed, contact KRI customer service, include the sub-
code XX.
_____________________________________________________________________
August 9, 2005
1-125
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4501
ANYBUS) OUT/FB.CTRL release timeout. XX
Access to the input signal reading area is not released due to defective hardware.
⇒ Check LED indicator on the interface card, and reset the error.
⇒ If the error message is still displayed contact KRI customer service, include the sub-
code XX.
_____________________________________________________________________
ERROR CODE E4510
DN) Master status. XX
The status of the master port changed due to faulty communication, caused by cable
disconnection during DeviceNet communication. XX indicates the status code.
⇒ Check the status sub-code XX and reset the error.
_____________________________________________________________________
ERROR CODE E4511
DN) Node status. XX
The status of the slave node changed due to faulty I/O communication, caused by
DeviceNet slave node cable disconnection.
⇒ Use the status sub-code XX as a troubleshooting aid.
⇒ Check the DeviceNet slave node cable and connections, and repair as necessary.
_____________________________________________________________________
ERROR CODE E4512
ABM-DN) Mailbox error.
An error is returned because data sent the mailbox is not accepted due to incorrect
DeviceNet parameter setting.
⇒ Ensure the MAC_ID specified for the slave node and the parameter settings are
correct, and re-execute DEVNET command.
_____________________________________________________________________
ERROR CODE E4520
ABMA-PDP) Status STOP. XX
During I/O communication in auto clear mode, an error occurred in the slave node and
the status of AnyBus PROFIBUS-DP master changed to STOP.
⇒ Check the connections of the fieldbus cable and repair as necessary.
⇒ Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
1-126
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4521
ABMA-PDP) Status OFFLINE. XX
An error occurred in the ABMA-PDP module, and the status of AnyBus PROFIBUS-DP
master changed to OFFLINE.
⇒ Use the sub-sub-code XX as a troubleshooting aid, clear the cause of the error and
reset the error.
⇒ If the error recurs, cycle the controller power OFF and ON.
_____________________________________________________________________
ERROR CODE E4522
ABMA-PDP) I/O data communication error. XX
During I/O communication, configuration data is downloaded to the interface card, then
communication is disconnected.
⇒ Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
ERROR CODE E4523
ABMA-PDP) sending of timed out I/O data. XX
The ABMA-PDP module is overloaded and output signals from the AS system cannot
be processed within the allowed time.
⇒ Check the fieldbus cable connections and repair as necessary.
⇒ Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
ERROR CODE E4524
ABMA-PDP) Timeout of receiving I/O data. XX
ABMA-PDP module overload, input signals from the slave cannot be processed within
the allowed time.
⇒ Check the fieldbus cable and connections, repair/replace as necessary.
⇒ Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
August 9, 2005
1-127
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4525
ABMA-PDP) Timeout of sending message. XX
ABMA-PDP module overload, sending message cannot be processed within the allowed
time.
⇒ Check the fieldbus cable and connections, repair/replace as necessary.
⇒ Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
ERROR CODE E4526
ABMA-PDP) Timeout of receiving message. XX
ABMA-PDP module overload, receiving message cannot be processed within the al-
lowed time.
⇒ Check the fieldbus cable and connections, repair/replace as necessary.
⇒ Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
_____________________________________________________________________
ERROR CODE E4527
ABMA-PDP) Check configuration data. XX
Incorrect configuration data or bus parameter is downloaded. Download cannot be
completed after error reset.
⇒ Use the sub-code XX as a troubleshooting aid, ensure correct configuration data and
bus parameters are used and re-execute download.
⇒ If the number of external I/O signals is changed, cycle controller power OFF and ON.
_____________________________________________________________________
ERROR CODE E4528
PROFIBUS) Slave Diag-error response detected. XX
Incorrect slave diagnosis command parameter is entered. If sub-code XX=A1 (hexa-
decimal notation), the node address used is out of range.
⇒ Ensure the correct parameters and node address are used.
⇒ Check the fieldbus cable and connections, repair/replace as necessary.
_____________________________________________________________________
1-128
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E4529
PROFIBUS) Statistic counter-error response detected. XX
Incorrect slave diagnosis command parameter is entered.
⇒ Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.
⇒ Ensure the correct parameters and node address are used.
_____________________________________________________________________
ERROR CODE E4530
DN) DeviceNet cable is disconnected.
DeviceNet cable connected to the slave device is disconnected while system switch
DN_DISCON_ERR is ON.
⇒ Reset the error in teach mode, and move the robot to a pose to enable access for
troubleshooting.
⇒ Check the DeviceNet cable and connections, repair/replace as necessary.
_____________________________________________________________________
ERROR CODE E5000
Connected permission signal has not been turned ON.
Dedicated gun connection “OK” signal is OFF when gun connection is executed.
⇒ Ensure gun connection “OK” signal is ON, re-execute gun connection.
_____________________________________________________________________
ERROR CODE E5001
RWC type is not process control type.
This error occurs when welder type setting is set to adaptive control and the weld con-
troller connected to the system is not an adaptive control type.
⇒ Ensure welder type setting is correctly set to adaptive control or constant current
control.
_____________________________________________________________________
ERROR CODE E5002
1GS board is not process control type.
This error occurs when welder type setting is set to adaptive control and the 1GS board
and 1GS board software are not compatible with adaptive control.
⇒ Replace the 1GS board and 1GS board software with adaptive control components.
_____________________________________________________________________
August 9, 2005
1-129
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5003
Illegal extend (retract) output signal.
Occurs when the output signals for the extend and retract operation of a spot welding
application are not properly set.
⇒ Check the setting in AUX 0605.
_____________________________________________________________________
ERROR CODE E5004
Weld completion signal already input.
Displayed when the weld completion signal is received before the weld initiate output.
Main causes include:
1. Weld completion signal is not set OFF, after the last welding step.
2. Before the weld completion signal is set OFF, the robot started execution of the next
welding step.
⇒ Check operation of welding equipment (gun and weld controller/timer), check the
signal number setting in AUX 0605-11, repair/modify as necessary.
⇒ Check the 1KA/1GW (1HW) boards and replace as necessary.
⇒ Check the interlock circuit and repair as necessary.
⇒ Check program data, weld timing, and welding data settings, modify as necessary
_____________________________________________________________________
ERROR CODE E5005
Welding schedule setting data is abnormal.
(Spot weld specifications type B)
The weld conditions set for the program welding point are out of range or not set for
clamp 1.
⇒ Ensure the correct weld conditions are set for the program weld point.
_____________________________________________________________________
ERROR CODE E5006
CLAMP SPEC is not set PULSE.
The error occurs when the spot weld clamp signal specification in the system (robot
system switch RWC=ON) is set to level instead of pulse.
⇒ Ensure the spot weld clamping signal specification is set to pulse using the
SETCLAMP AS Language command.
_____________________________________________________________________
1-130
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5007
Servo weld gun not connected or wrong gun connected.
(Servo spot weld gun only)
Main causes include:
1. The robot executes a step when a gun is not attached to the tool changer.
2. The gun number in the tool changer is different than the gun number specified for the
program step.
3. Incorrect gun number is read due to damaged gun harness.
⇒ Execute the step in manual mode or manually install the correct gun. In the teach or
check mode, verify connection of the gun by pressing the connect/separate button.
⇒ If the correct gun is attached to the tool changer, confirm that the gun signal number
(AUX 0605-41, GUN CONNECTION SIGNAL) is correct. From the MONITOR (IN-
PUT SIGNAL) screen, confirm that the signal number is received.
⇒ Inspect the connections between the gun and the 1FG board and repair as neces-
sary.
⇒ Check gun harness and connections and repair/replace as necessary.
⇒ Temporarily set the gun connect signal number (AUX 0605-41, GUN CONNECTION
SIGNAL) to 0 (when the gun connect number is set to 0, the error is not detected);
ensure that the correct gun is in the tool changer. Repair the gun connection and set
the gun connect signal number as soon as possible.
_____________________________________________________________________
ERROR CODE E5008
Tip wear measurement (stage 1) was not executed.
(Servo spot weld gun only)
The tip wear measurement program stage 2 (reference plate) is attempted, without first
performing stage 1.
⇒ Execute tip wear measurement program stage 1 prior to executing stage 2.
_____________________________________________________________________
ERROR CODE E5009
Work sensing signal (gun_tip touch signal) is not set.
(Servo spot weld gun only)
A workpiece thickness measurement is attempted, when the gun tip touch signal (set in
AUX 1021) has not been received.
⇒ Set the gun tip touch signal number (AUX 1021).
_____________________________________________________________________
August 9, 2005
1-131
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5010
Servo weld gun mechanical parameter is not set.
(Servo spot weld gun only)
A new gun is connected and the mechanical parameters are not defined in AUX 1021.
⇒ Define the parameters in AUX 1021.
_____________________________________________________________________
ERROR CODE E5011
This clamp number already set for servo weld gun axis.
(Servo spot weld gun only)
This error occurs when a servo spot weld gun number is duplicated using the ZAXIS AS
Language command or AUX 2002.
⇒ Ensure the servo spot weld gun numbers are not duplicated using the ZAXIS AS
Language command or AUX 2002.
_____________________________________________________________________
ERROR CODE E5012
Cannot change the gun because offset data is abnormal.
The encoder offset data set for the gun is different at time of gun change.
⇒ Ensure encoder offset data for all guns is the same.
_____________________________________________________________________
ERROR CODE E5013
Cannot change multiple guns at the same step.
(Servo spot weld gun only)
The operator is attempting to execute a step with more than one gun change.
⇒ Edit the program so that there is only one gun change per step.
_____________________________________________________________________
ERROR CODE E5014
Gun is connected other.
The tool changer is attempting to connect to a gun that is already connected to another
axis tool changer or is missing.
⇒ Select a different gun or disconnect the gun from the other tool changer.
_____________________________________________________________________
1-132
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5015
Gun status data disagrees with clamp condition.
(Servo spot weld gun only)
Incorrect program data is used.
Main causes include:
1. Clamp ON is taught in a step that includes a gun change.
2. Clamp OFF is taught in a step that includes a point for “wear measurement using
automatic clamping”, “wear measurement reference plate”, or “work position deviation
measurement”.
⇒ Ensure clamp OFF is taught in a step that includes a gun change.
⇒ Ensure clamp ON is taught in a step that includes a point for “wear measurement
using automatic clamping”, “wear measurement reference plate”, or “work position
deviation measurement”.
_____________________________________________________________________
ERROR CODE E5016
Data of SRVPRESS is wrong.
This error occurs when the welding clamp pressure change cycle ratio number for the
servo gun is other than SRV3PRESS, SRV4PRESS, SRV5PRESS, or SRV6PRESS.
⇒ Ensure the cycle ratio number is set correctly.
_____________________________________________________________________
ERROR CODE E5017
Wear base data is not registered.
This error occurs when the tip wear base data entry was not made and the tip wear
measurement operation is performed.
⇒ Ensure tip wear base data entry is performed before tip wear measurement operation
is performed.
_____________________________________________________________________
August 9, 2005
1-133
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5018
Weld completion signal has not been detected.
Occurs when a weld complete signal is not received in the allowed time period.
Main causes include:
1. Defective weld gun, weld controller/timer, cable, etc.
2. Defective 1KA/1GW (1HW) boards, or harness, etc.
3. Defective interlock circuit.
4. Noise related malfunction.
⇒ Check gun, weld controller/timer, cable, etc. and repair/replace as necessary.
⇒ Check 1KA/1GW (1HW) boards and harness and replace as necessary.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE E5019
Weld fault signal is detected.
Main causes include:
1. Defective weld gun, weld controller/timer, cable, etc.
2. Defective 1KA/1GW (1HW) boards, harness, etc.
3. Defective interlock circuit.
4. Noise related malfunction.
⇒ Check gun, weld controller/timer, cable, etc. and repair/replace as necessary.
⇒ Check 1KA/1GW (1HW) boards and harness and replace as necessary.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE E5020
Retract pos. monitor error.
Occurs when the input signal for the retract operation of a 2-stroke retractable gun is not
received.
Main causes include:
1. Defective weld gun, weld controller/timer, cable, etc.
2. Defective 1KA/1GW (1HW) boards, harness, etc.
3. Defective interlock circuit.
4. Incorrect retract position input signal setting.
5. Noise related malfunction.
⇒ Check gun, weld controller/timer, cable, etc. and repair/replace as necessary.
⇒ Check 1KA/1GW (1HW) boards and harness and replace as necessary.
⇒ Ensure the retract position input signal setting is correct.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
1-134
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5021
Extend pos. monitor error.
Occurs when the input signal for the extend operation of a 2-stroke retractable gun is not
received.
Main causes include:
1. Defective weld gun, weld controller/timer, cable, etc.
2. Defective 1KA/1GW (1HW) boards, harness, etc.
3. Defective interlock circuit.
4. Incorrect extend position input signal setting.
5. Noise related malfunction.
⇒ Check gun, weld controller/timer, cable, etc. and repair/replace as necessary.
⇒ Check 1KA/1GW (1HW) boards and harness and replace as necessary.
⇒ Ensure the extend position input signal setting is correct.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE E5022
Current gun retract position differs from a destination.
In the check mode, retractable gun output signals are monitored and compared to clamp
condition code and open/close data for a specific step. If the data does not match, this
error is displayed.
⇒ Ensure settings in clamp condition code and open/close data match output signal
settings, check operation of gun with the clamp key.
_____________________________________________________________________
ERROR CODE E5023
Wear is abnormal, cannot take measurement.
When executing tip wear measurement, the moving or fixed tip wear exceeds the al-
lowed value.
⇒ Replace the worn gun tip.
⇒ Ensure tip wear measurement data is correct.
_____________________________________________________________________
August 9, 2005
1-135
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5024
Pressurization comp. signal has not been detected.
Pressurization completion signal is not received from the weld controller/timer.
Main causes include:
1. Defective weld controller/timer.
2. Defective servo spot weld gun.
3. Defective harness, cable, etc.
⇒ Check weld controller/timer, servo spot weld gun, harnesses, and cables and repair/
replace as necessary.
_____________________________________________________________________
ERROR CODE E5025
Gun opening comp. signal has not been detected.
Gun opening completion signal is not received from the servo weld gun.
Main causes include:
1. Defective servo spot weld gun.
2. Defective servo spot weld gun cable, cable connections, tool changer, etc.
⇒ Check the servo spot weld gun, servo spot weld gun cable, cable connections, and
tool changer contacts and connections and repair/replace as necessary.
_____________________________________________________________________
ERROR CODE E5026
RWC error -xx.
(Spot weld specifications type B)
(-xx: represents the welder number)
The current flow from the specified remote weld controller (RWC) Is abnormal.
Main causes:
20: SCR overheat
22: Power failure
21: Memory abnormal
23: System error
24: Defective electro-valve (gun control valve)
Main causes include:
Insufficient SCR cooling, a memory data error, weld current is not synchronized with gun
clamp conditions, system error, or gun control valves malfunction.
⇒ Check welder and weld gun repair/replace as necessary.
⇒ Check 1GS board, and communication cables repair/replace as necessary.
_____________________________________________________________________
1-136
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5027
Robot stopped during weld.
(Spot weld specifications type C)
(Servo spot weld gun only)
This error occurs when the robot is placed in a HOLD or an E-STOP condition after the
clamp output signal is sent, and before the weld complete signal is received.
⇒ Return the system to normal operation and re-execute weld.
_____________________________________________________________________
ERROR CODE E5028
Cannot achieve set force.
The gun does not obtain the set closing pressure within 5 seconds after the gun starts
closing.
Main causes include:
1. Tip wear measurement is not executed.
2. Incorrect taught point (closing pressure is not defined for the recorded position).
3. Closing pressure is set too high.
4. Workpiece is too thin.
5. Incorrect lower limit motion setting (LLIMIT command).
⇒ Perform the tip wear measurement.
⇒ Reteach the point.
⇒ Decrease the closing pressure.
⇒ Ensure the workpiece specifications are correct and the workpiece is in the correct
position.
⇒ Ensure lower limit motion is set correctly (LLIMIT command).
_____________________________________________________________________
ERROR CODE E5029
Gun tip stuck.
Indicates that the tips are stuck. More power is required to open the gun, following a
weld, than the stuck detection value, set in AUX 1021 Force for Stuck Detection [kgf].
If the stuck detection value is set below the power level required for normal operation,
the gun cannot operate properly and the error is set.
⇒ If the gun is stuck, release it manually.
⇒ If the gun is not stuck, verify that the stuck detection value (AUX 1021, Force for
Stuck Detection [kgf]) is set correctly. This setting may need to be increased.
_____________________________________________________________________
August 9, 2005
1-137
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5030
Copper plate wear exceeds limit. step=XX.
(Servo spot weld gun only)
The copper backing plate wear exceeds the copper plate wear limit (AUX 1029). The
error is detected when the gun executes a weld.
⇒ Replace the copper backing plate.
_____________________________________________________________________
ERROR CODE E5031
Weld completion signal is not turned off.
This error occurs when the weld completion and weld initiate signals are high (ON) at
the same time for three seconds.
⇒ Change the weld complete signal to a pulsed signal with a duration of less than three
seconds.
⇒ Set the weld complete signal OFF using the rising-edge-trigger in the welding instruc-
tion.
_____________________________________________________________________
ERROR CODE E5032
Calibration did not end normally.
(Servo spot weld gun only)
During calibration operation after a gun change calibration is aborted.
Main causes include:
1. E-stop condition.
2. Changing modes during calibration.
⇒ Reset the error and perform a manual gun change.
_____________________________________________________________________
1-138
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E5033
Cannot weld because of abnormal thickness.
(Servo spot weld gun only)
The thickness of the workpiece is out of tolerance.
Main causes include:
1. Defective workpiece.
2. Incorrect positioning of the workpiece.
3. A gap between the two panels being welded.
4. Current tip wear (AUX 1029) and actual tip wear are different.
⇒ Inspect the workpiece. Measure the thickness and positioning; replace workpiece
and/or correct abnormal positioning.
⇒ Execute the tip wear measurement program. Manually measure the tip wear; com-
pare these measurements to the current tip wear data (AUX 1029).
_____________________________________________________________________
ERROR CODE E5034
Tip wear exceeds limit. (MOVING SIDE)
Moving tip wear exceeds the set maximum wear limit during wear measurement.
⇒ Replace the moving tip.
_____________________________________________________________________
ERROR CODE E5035
Tip wear exceeds limit. (FIXED SIDE)
Fixed tip wear exceeds the set maximum wear limit during wear measurement.
⇒ Replace the fixed tip.
_____________________________________________________________________
ERROR CODE E6001
Step after XD(2)START must be LMOVE or HMOVE.
Incorrect motion instruction is taught. The step following XD(2)START requires an
LMOVE or HMOVE motion instruction for touch sensing.
⇒ Ensure the step following XD(2)START is an LMOVE or HMOVE.
_____________________________________________________________________
August 9, 2005
1-139
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6002
Signal condition already input.
The signal condition is already met when an XDMOVE or XD(2)START move is ex-
ecuted and the signal monitoring starts.
⇒ Check input signal timing for the door open detection signal and the monitored sig-
nals, and correct interlock data or program data as necessary.
_____________________________________________________________________
ERROR CODE E6003
Door open detect signal is not dedicated.
During XD(2)START execution, the input signal for door open state is not set as a dedi-
cated input signal.
⇒ Set the input signal from the sensor for detecting door open/close state as a dedi-
cated input signal.
_____________________________________________________________________
ERROR CODE E6004
Location data was not detected.
An attempt to acquire compensation value from the door open state sensor is made, but
the pose data that incorporates the compensation value could not be acquired because
the door detecting instruction was not executed.
⇒ Check the program data and add XDMOVE or XD(2)START before executing XDGET
instruction.
_____________________________________________________________________
ERROR CODE E6006
Signal not detected.
Main causes include:
1. As the robot moves the specified distance per XDMOVE or XD(2)START with sensing
enabled, the monitored signal condition is not met.
2. Signal condition is not met within the time specified by DIN_WAIT instruction.
⇒ Check the timing of the door open detection input signal and the signals monitored by
XDMOVE or XD(2)START, and correct the interlock data or program data as neces-
sary.
_____________________________________________________________________
1-140
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6007
Wrist can’t be straightened any more (Singular point 1).
The posture of JT5 is set too close to 0 degrees (or a multiple of 360 degrees) on a
robot equipped with a 3S type wrist.
NOTE
This does not normally occur in joint mode, but may oc-
cur with conveyor synchronous function enabled.
⇒ Change wrist posture.
⇒ Move the robot in joint interpolation.
⇒ Change the wrist posture before enabling conveyor synchronous function, to prevent
this error.
_____________________________________________________________________
ERROR CODE E6008
Wrist can’t be bent any more. (Singular point 2).
The posture of JT5 is set too close to 180 degrees (or multiple of 360 degrees) on a
robot equipped with a 3S wrist.
NOTE
This does not normally occur in joint mode, but may oc-
cur with conveyor synchronous function enabled.
⇒ Change wrist posture.
⇒ Move the robot in joint interpolation.
⇒ Change the wrist posture before enabling conveyor synchronous function, to prevent
this error.
_____________________________________________________________________
August 9, 2005
1-141
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6012
Relative distance between guns is too near.
The gun tips of two networked robots is less than the minimum specified distance for the
application.
⇒ If this error occurs in teach mode, drive the axes so the distance between gun tips is
within specified value.
⇒ If this error occurs in check/repeat mode, modify the program data, and change the
motion timing and relative distance.
NOTE
If this error does not occur in a near-miss condition,
check the distance (and home position) set for error de-
tection for the robot pair.
_____________________________________________________________________
ERROR CODE E6500
No welding interface board.
The welding interface (1GN) board is not detected at control power ON.
⇒ Turn control power off and confirm that the welding interface (1GN) board is mounted
to the 1GW (1HW) board.
⇒ Confirm that the welding interface (1GN) board is not loose. Insert the board firmly.
⇒ Replace the 1GW/1GN (1HW/1GN) board.
_____________________________________________________________________
ERROR CODE E6501
No. 2 welding interface board not found.
The polarity ratio function is set for analog output, or an additional 1GW (1HW) board is
required for 3, or more, analog output channels.
⇒ Install additional 1GW (1HW) board as required.
⇒ Ensure 1GW (1HW) boards are properly installed.
_____________________________________________________________________
1-142
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6502
Arc failure.
The signal (current detection: WCR) that indicates the robot is executing the weld was
not returned from the weld controller/timer within 1 second, or less, after welding
started.
Main causes include:
1. Arc is not generated when welding starts.
2. Arc generation is interrupted for 1, or more, seconds during welding.
⇒ Check for insulating debris that prevents welding, clear debris as necessary.
⇒ Confirm that adequate supply of wire is available.
⇒ Confirm that wire is not stuck to the welding tip.
⇒ Check weld controller/timer and cables, repair/replace as necessary.
_____________________________________________________________________
ERROR CODE E6503
Wire stuck.
Main causes include:
1. Welding and crater fill are completed and the arc is set OFF, but a weld stuck detec-
tion signal is received. The weld stuck detection signal does not clear after the es-
cape process is executed.
2. The wire is stuck to the base metal at weld completion.
⇒ Cut the wire and re-execute weld.
⇒ Change weld conditions if problem occurs frequently.
_____________________________________________________________________
ERROR CODE E6504
Arc start failed.
The signal (current detection: WCR), that indicates the robot is executing the weld, is not
return from the weld controller/timer at welding start.
Main causes include:
1. Insulating debris that prevents welding.
2. Welding wire feed supply ran out, or wire is stuck to welding tip.
⇒ Check for insulating debris that prevents welding, clear debris as necessary.
⇒ Confirm that adequate supply of wire is available.
⇒ Confirm that wire is not stuck to the welding tip.
_____________________________________________________________________
August 9, 2005
1-143
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6505
Arc weld insulation defect.
This error occurs when robot movement causes insulation failure.
⇒ Ensure the welder, torch, and robot insulation are in good working condition.
_____________________________________________________________________
ERROR CODE E6506
Torch interference.
The limit switch for torch interference detection is tripped or damaged.
After the error is reset the robot can be moved in teach mode. The robot cannot be
moved in repeat mode until the limit switch is reset.
⇒ Move the robot away from the interference to close the limit switch. Inspect the torch
for damage.
⇒ Determine the cause of the interference before continuing operation.
⇒ Replace damaged limit switch and/or harness, as necessary.
_____________________________________________________________________
ERROR CODE E6507
Illegal interpolation data.
A welding step is taught as joint interpolation with arc welding specification software.
⇒ Welding steps must use linear or circular interpolation for arc welding specification
software. Ensure the interpolation is correct.
_____________________________________________________________________
ERROR CODE E6509
No work detected.
(Touch sensing)
Occurs when touch sensing does not detect the workpiece within the range of the touch
sensing distance set in system data, or no workpiece is present.
⇒ Reset the workpiece in the proper position.
⇒ Increase the range of touch sensing distance in system data (increases touch sens-
ing time).
_____________________________________________________________________
1-144
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6510
Undefined sensing direction.
(Touch sensing)
Occurs when the step proceeding the WORK_DETECT instruction is not an air_cut
point.
⇒ Insert an air_cut point in the program before the WORK_DETECT instruction.
⇒ When using step select to chose the start step, select the air_cut point before the
WORK_DETECT instruction in the program.
_____________________________________________________________________
ERROR CODE E6511
Insufficient num. of sensing points.
(Touch sensing)
The number of steps taught with the work deviation compensation function is insufficient
for the number of sensing points, or an air_cut point is not taught immediately following
the sensing point.
Example:
1. AC JOINT SPEED9 ACCU4 TIMER0 MOTHER_RESET
2. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK2 (error occurs at this step)
3. WS LINEAR SPEED9 TIMER0
Step set two pattern 2 (with 2 sensing points) and step 3 is a weld start point instead of
an air_cut point.
⇒ Add the required air_cut sensing points (two points in this example).
Example:
2. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK2
3. AC JOINT SPEED9 ACCU4 TIMER0
4. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK2
5. WS LINEAR SPEED9 TIMER0
_____________________________________________________________________
August 9, 2005
1-145
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6512
Undefined mother or daughter work.
(Touch sensing)
Main causes include:
1. A previous work instruction is not completed before another work instruction is ex-
ecuted.
2. Program execution is started at a step in that does not allow completion of a previous
work instruction.
Example:
1. AC JOINT SPEED9 ACCU4 TIMER0 MOTHER_RESET
2. AC LINEAR SPEED9 ACCU4 TIMER0 DAUGHTER_WORK2 (error occurs at this
step)
⇒ Add the required steps in the program to complete the first work instruction before
another work instruction is executed (in this example a step is inserted before step 2).
Example:
1. AC JOINT SPEED9 ACCU4 TIMER0 MOTHER_RESET
2. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK1
3. AC LINEAR SPEED9 ACCU4 TIMER0 DAUGHTER_WORK2
_____________________________________________________________________
ERROR CODE E6513
Too many sensing points.
(Touch sensing)
Occurs when a work instruction is completed and another work instruction is executed
without a reset instruction.
Example:
1. AC JOINT SPEED9 ACCU4 TIMER0 MOTHER_RESET
2. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK1
3. AC LINEAR SPEED9 ACCU4 TIMER0
4. WS LINEAR SPEED9 TIMER0
5. WE LINEAR WELD_COND0
6. AC LINEAR SPEED9 ACCU4 TIMER0
7. WS LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK1 (error occurs at this step)
⇒ Add a reset instruction before the next work instruction.
Example:
6. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_RESET
7. WS LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK1
_____________________________________________________________________
1-146
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6514
Work specification incorrect.
(Touch sensing)
Occurs when a previous work instruction is not completed before another work instruc-
tion is executed.
Example:
1. AC JOINT SPEED9 ACCU4 TIMER0 MOTHER_RESET
2. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK2
3. AC LINEAR SPEED9 ACCU4 TIMER0
4. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK1 (error occurs at this step)
⇒ Add the required steps in the program to complete the first work instruction before
another work instruction is executed.
Example:
4. AC LINEAR SPEED9 ACCU4 TIMER0 MOTHER_WORK2
_____________________________________________________________________
ERROR CODE E6515
Incorrect sensing point specified.
(Touch sensing)
Occurs when points are taught in incorrect order.
Example:
points should be taught in order A1, B1, A2, B2, A3, B3.
Occurs when the distance between two points taught on the same check plane is
10 mm, or less, or the angle, between the two sensing surfaces, is out of range (30 to
150 degrees).
⇒ Reteach points to comply with parameters described above.
_____________________________________________________________________
August 9, 2005
1-147
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6516
Wire check failure.
(Touch sensing)
Main causes include:
1. The position of a taught point is recorded too far from the workpiece, and the wire tip
did not touch the work within the allowed time.
2. The weld wire is not sent due to the welding unit power off etc.
⇒ Reteach point at the correct distance.
⇒ Ensure workpiece is within specifications and is properly placed.
⇒ Check the welding machine for power and press CYCLE START to manually feed
wire for five seconds.
⇒ Check the wire supply, wire feeder, and welding equipment and repair/replace as
necessary.
_____________________________________________________________________
ERROR CODE E6517
incorrect weld condition number.
The weld condition number, is not within the acceptable range (1–20).
Example: W1SET 100=60, 250, 28, 2, 3 Weld condition 100 is out of range (1–20).
⇒ Set weld condition within range.
Example: W1SET 1=60, 250, 28, 2, 3
_____________________________________________________________________
ERROR CODE E6518
No weld condition data set.
Weld data is not set in the weld condition number specified.
Example: Weld condition 1 is not set for LWC #a1, 1
⇒ Ensure weld data is set in the specified weld condition number used.
Example: W1SET 1=60, 250, 28, 2, 3
_____________________________________________________________________
1-148
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6519
Weld condition data out of range.
Ensure data is within range as shown below.
Current:
Voltage:
Speed:
Time:
Weaving width:
Weaving frequency:
Weaving pattern:
0–999 Amp
0–99.9 Volt
0–999 cm/min
0–9.9 second
0–40.0 mm
0–4.0 Hz
0–9
⇒ Correct weld condition data as necessary.
_____________________________________________________________________
ERROR CODE E6520
Laser sensor tracking value exceeded.
Tracking deviation exceeds the allowed threshold value to permit welding, and continues
to exceed the value longer than time allowed for normal operation.
Main causes include:
1. Workpiece is improperly placed.
2. Error check value is set too low.
⇒ Ensure the workpiece is properly placed.
⇒ Ensure the error check value is set correctly.
_____________________________________________________________________
ERROR CODE E6521
Beyond laser sensor tracking ability.
The difference between the over-tracking ability detection start value and the current
over-tracking value, exceeds the threshold value set.
Main causes include:
1. Workpiece is improperly placed.
2. Error check value is set too low.
⇒ Ensure the workpiece is properly placed.
⇒ Ensure the error check value is set correctly.
_____________________________________________________________________
August 9, 2005
1-149
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6522
Laser sensor cannot detect welding joint.
Main causes include:
1. The laser sensor unable to find a groove.
2. The laser sensor detects a groove that does not match the specified groove number
data.
3. The laser sensor controller EMERGENCY STOP switch is pressed.
4. Incorrect laser sensor settings or defective laser sensor.
⇒ Re-teach the groove data.
⇒ Ensure the correct groove number is specified.
⇒ Release the laser sensor controller EMERGENCY STOP switch.
⇒ Refer to the laser sensor operation manual and ensure correct set-up and operation
procedures are used.
_____________________________________________________________________
ERROR CODE E6523
Calibration data between torch and camera is not ready.
Calibration data is not set (LTCALIB command).
⇒ Set the calibration data using the LTCALIB command.
_____________________________________________________________________
ERROR CODE E6524
Error in data calculated using laser sensor.
Processing based on laser sensor data could not be calculated.
⇒ Readjust the laser sensor so 80 percent or more of grooves are correctly detected.
⇒ If the error cannot be reset after laser sensor readjustment, contact KRI customer
service.
_____________________________________________________________________
ERROR CODE E6525
Cannot detect weld joint, laser sensor tracking set already.
Main causes include:
1. A PC program executes a function, such as LSEN, during execution of a program
using a laser sensor.
2. During execution of a function, such as the LSEN, a program using a laser sensor is
executed.
⇒ Correct program data so the laser sensor is not used by two instructions at the same
time.
_____________________________________________________________________
1-150
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6526
No response from laser sensor controller.
Main causes include:
1. Disconnected or defective laser sensor harness.
2. Incorrect laser sensor settings or defective laser sensor.
⇒ Check laser sensor, laser sensor harness and connections and repair/replace as
necessary.
⇒ Refer to the laser sensor operation manual and ensure correct set-up and operation
procedures are used.
_____________________________________________________________________
ERROR CODE E6527
Laser sensor communication error. Code is XX.
Incorrect laser sensor settings or defective laser sensor.
⇒ Refer to the laser sensor operation manual for sub-code XX and ensure correct set-
up and operation procedures are used.
_____________________________________________________________________
ERROR CODE E6528
Start point not found by laser sensor.
Main causes include:
1. The laser sensor unable to find a groove.
2. The laser sensor detected a groove that does not match the specified groove number
data.
3. The laser sensor controller EMERGENCY STOP switch is pressed.
4. Incorrect laser sensor settings or defective laser sensor.
⇒ Re-teach the groove data.
⇒ Ensure the correct groove number is specified.
⇒ Release the laser sensor controller EMERGENCY STOP switch.
⇒ Refer to the laser sensor operation manual and ensure correct set-up and operation
procedures are used.
_____________________________________________________________________
August 9, 2005
1-151
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6529
Finish point not found by laser sensor.
Main causes include:
1. The laser sensor unable to find a groove.
2. Auto tracking function is enabled with no data present, and finish point detection
failed.
⇒ Re-teach data, or readjust the detection range for the finish point.
⇒ Disable auto tracking function ID because there is no data, and re-execute finish point
detection.
_____________________________________________________________________
ERROR CODE E6530
Cannot use circular interp. with laser sensor function.
Laser sensor tracking function is used with circular interpolation.
⇒ Do not use circular or linear interpolation with laser sensor tracking function.
_____________________________________________________________________
ERROR CODE E6531
Cannot turn laser ON because motor power is OFF.
Attempt to use laser sensor when motor power is OFF.
⇒ Set motor power ON and re-execute.
_____________________________________________________________________
ERROR CODE E6532
No communication board to laser sensor.
The laser sensor 1HA communication board is not installed.
⇒ Ensure the laser sensor 1HA communication board is properly installed.
_____________________________________________________________________
1-152
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6533
No RTPM board.
Main causes include:
1. The software for RTPM option is installed, but the hardware (1FH board) is not in-
stalled properly.
2. Hardware for RTPM (1FH board) is installed, but the software for RTPM option is not
installed.
2. The software and hardware (1FH board) are installed, but controller power was not
cycled OFF and ON after RTPM option is set-up.
⇒ Ensure the 1FH board is properly installed.
⇒ Reseat the 1FH board and connectors.
⇒ Perform RTPM option set-up procedure and cycle controller power OFF and ON.
_____________________________________________________________________
ERROR CODE E6534
Too many taught points for RTPM.
Occurs when the number of taught points, between the weld start point and the weld
end point, exceeds 127 points
⇒ Reteach program points, not to exceed 127 RTPM points.
_____________________________________________________________________
ERROR CODE E6535
RTPM arc sensor error.
Exceeded the number of weaves set for arc sensor fault detection, and the lateral (+)
and (-) values for current are less than 10 A, more than 490 A, or the difference is
0.2 A, or less.
Main causes include:
1. Weld start-point is too far from the groove.
2. Defective weld controller/timer, or weld controller/timer set OFF.
⇒ Ensure the wiring for the current sensor for RTPM is not loose or disconnected.
⇒ Ensure the weld start-point is taught in the welding groove.
⇒ Ensure the welder is powered-up and in normal operating condition.
⇒ Weld with RTPM disabled, check for problems with the weld controller/timer and
repair/replace as necessary.
_____________________________________________________________________
August 9, 2005
1-153
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6536
RTPM current deviation error.
Occurs when actual current exceeds commanded current (feedback current) for a time
period exceeding the current deviation error time-out value.
Main causes include:
1. Weld start-point is too far from the groove.
2. Defective weld controller/timer, or weld controller/timer set OFF.
3. Incorrect linearization or offset/gain.
⇒ Ensure the weld start point is taught in the welding groove.
⇒ Set controller power to OFF and reseat the 1FH board and the 1FH board connec-
tors.
⇒ Ensure the welding unit power is ON and in proper operating condition.
⇒ Ensure the RTPM function is activated.
⇒ Ensure the welding unit metered current, during a continuous bead, is the same as
the commanded current.
⇒ Ensure values set for linearization or offset/gain are correct.
⇒ Weld with RTPM disabled, and check for problems with the weld controller/timer and
repair/replace as necessary.
_____________________________________________________________________
ERROR CODE E6537
RTPM tracking value is out or range.
Occurs when the deviation detection value exceeds the error check value set in RTPM,
continuously, exceeding the number of times allowed.
Main causes include:
1. Weld start-point is too far from the groove.
2. Defective weld controller/timer, or weld controller/timer set OFF.
3. The deviation error detection value is set too low.
⇒ Ensure the weld start point is taught in the welding groove.
⇒ Weld with RTPM disabled, and check for problems with the weld controller/timer and
repair/replace as necessary.
⇒ If the welding groove is being tracked normally, the deviation error detection value
may be set too low. Increase the value.
_____________________________________________________________________
1-154
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6538
Beyond RTPM tracking ability.
Occurs when the current tracking value exceeds the threshold value and the number of
times value set for RTPM tracking ability errors.
Example:
If the threshold is set at 9 mm, and the number of times is set at 30, the error occurs
after 30 weave cycles and the path deviates more than 9 mm from the original welding
path.
Main causes include:
1. Weld start-point is too far from the groove.
2. Defective weld controller/timer, or weld controller/timer set OFF.
3. The deviation error detection value is set too low.
⇒ Ensure the welding start point is taught in the groove. Starting outside the groove will
cause this error.
⇒ Execute a weld, without the RTPM function, to ensure the weld controller/timer is
operating properly.
⇒ Modify fixturing and/or part to minimize the required correction.
⇒ Verify the linearization table is correct by comparing the current reading indicated on
the weld controller/timer to the current value set in the weld condition number.
⇒ If the welding groove is being tracked normally, the deviation error detection value
may be set too low. Increase the value.
_____________________________________________________________________
ERROR CODE E6539
AVC tracking value is out of range.
The tracking deviation value, used as the threshold for error detection, is exceeded
continuously.
Main causes include:
1. Weld start-point is too far from the groove.
2. Defective weld controller/timer, or weld controller/timer set OFF.
3. The deviation error detection value is set too low.
⇒ Ensure the welding start point is taught in the groove. Starting outside the groove will
cause this error.
⇒ Execute a weld with AVC disabled, to ensure the weld controller/timer is operating
properly.
⇒ If the welding groove is being tracked normally, the deviation error detection value
may be set too low. Increase the value.
_____________________________________________________________________
August 9, 2005
1-155
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6540
Beyond AVC tracking ability.
Occurs when the current tracking value exceeds the threshold value and the number of
times value set for RTPM tracking ability errors.
Main causes include:
1. Weld start-point is too far from the groove.
2. Defective weld controller/timer, or weld controller/timer set OFF.
3. The deviation error detection value is set too low.
⇒ Ensure the welding start point is taught in the grove. Starting outside the grove
causes this error.
⇒ Execute a weld with AVC disabled, to ensure the weld controller/timer is operating
properly.
⇒ If the welding groove is being tracked normally, the deviation error detection value
may be set too low. Increase the value.
_____________________________________________________________________
ERROR CODE E6541
No AVC board.
Main causes include:
1. AVC (1FH) board is not installed onto the 1KA board.
2. Controller power is not cycled OFF and ON after setting specifications.
⇒ Ensure the AVC (1FH) board is properly installed.
⇒ Replace the AVC board.
⇒ Cycle controller power OFF and ON after setting specifications.
_____________________________________________________________________
ERROR CODE E6542
AVC voltage deviation error.
During AVC function execution, the reference voltage and/or feedback voltage exceeds
the threshold value specified for over-voltage detection.
Main causes include:
1. Defective weld controller/timer, or weld controller/timer set OFF.
2. Defective harness or harness connections.
⇒ Execute a weld with AVC disabled to ensure the weld controller/timer is operating
properly.
⇒ Check the voltage sensing device and harness, and repair/replace as necessary.
_____________________________________________________________________
1-156
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E6543
Too many taught points for AVC.
Occurs when the number of taught points between the weld start point and the weld end
point exceeds 127 points.
⇒ Reteach program points, not to exceed 127 RTPM points.
_____________________________________________________________________
ERROR CODE E6562
Electric pole stuck.
The electrode is stuck to the base metal during TIG welding.
⇒ Cut the electrode.
⇒ Change weld conditions if problem occurs frequently.
_____________________________________________________________________
ERROR CODE E7000
Servo weld gun disconnect.
When a welding step is executed the servo spot weld gun is not connected.
⇒ Connect the servo spot weld gun and re-execute.
_____________________________________________________________________
ERROR CODE E7001
Location data includes released gun status data.
The servo weld gun axis position value data indicates the gun is disconnected.
⇒ Use the correct gun disconnect procedure.
_____________________________________________________________________
ERROR CODE E7002
Destination is far from target point.
Program point is too far from the taught point.
⇒ Contact KRI customer service (include operating conditions/settings at the time the
error occurred).
_____________________________________________________________________
August 9, 2005
1-157
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE E8200
Not in cooperative mode.
Cooperative motion instruction is taught before MASTER/SLAVE instruction or after
ALONE instruction.
⇒ Use cooperative motion instructions between MASTER/SLAVE instruction and
ALONE instruction.
_____________________________________________________________________
1-158
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.3.2.3 PXXXX OPERATION ERROR CODES
ERROR CODE P0100 Illegal input data.
AS Language command/instruction does not comply with AS Language syntax.
⇒ Enter AS Language command/instruction in correct AS Language syntax.
_____________________________________________________________________
ERROR CODE P0101
Too many arguments.
AS Language command/instruction exceeds the number of user specified items allowed
by the format.
⇒ Enter AS Language command/instruction in correct AS Language syntax and format
for the command/instruction used.
_____________________________________________________________________
ERROR CODE P0102
Input data is too big.
AS Language command/instruction data exceeds the allowable range.
⇒ Enter data that is within acceptable range.
_____________________________________________________________________
ERROR CODE P0103
Illegal PC number.
PCEND command/instruction specified a PC program number that is out of the allow-
able range.
⇒ PC program number must be -1 or 1–5.
Example: PCEND 2
_____________________________________________________________________
ERROR CODE P0104
Illegal robot number.
A robot number is specified that exceeds the number of robots connected to the control-
ler.
Example: “LLIMIT 3” is entered when 2 robots are connected to the controller.
⇒ Ensure robot number does not exceed the number of robots connected to controller.
Example: “LLIMIT 2” can be used when 2 robots are connected to the controller.
_____________________________________________________________________
August 9, 2005
1-159
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0106
Illegal priority.
Priority level designation is out of the allowable range (1–127).
Example: LOCK 128
⇒ Ensure the correct priority level number is entered (1–127).
Example: LOCK 2
_____________________________________________________________________
ERROR CODE P0107
Invalid coordinate value.
Upper limit value is less than lower limit value for work space output data.
⇒ Enter the correct upper limit coordinates.
_____________________________________________________________________
ERROR CODE P0108
Syntax error.
Occurs when an AS Language command is entered that does not follow the correct
syntax.
⇒ Correct the syntax, format or spelling of the command/instruction.
_____________________________________________________________________
ERROR CODE P0109
Invalid statement.
Main causes include:
1. An AS Language command is entered that has typing errors, incorrect spelling or is in
the wrong format.
2. An existing variable name, that is already used for a variable of a different type, is
used.
⇒ Correct the syntax, format or spelling of the command/instruction.
⇒ Do not use existing variable names.
_____________________________________________________________________
ERROR CODE P0110
Specify full spelling of command.
Displayed when an abbreviation is entered incorrectly or has missing letters.
⇒ Enter the correct abbreviation or use the full spelling of the command.
_____________________________________________________________________
1-160
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0111
Cannot use this command/instruction in current mode.
The command/instruction entered could not be executed in the selected mode.
Example: “EDIT” is entered in the program edit mode (used in monitor mode).
Example: “TERMOFF” is entered from the teach pendant keyboard (used from a PC
terminal).
⇒ Ensure correct mode is selected.
_____________________________________________________________________
ERROR CODE P0114
Illegal expression.
A command/instruction is entered that does not comply with AS Language syntax or
format.
Example: “DO HERE” the DO command cannot be used with the HERE command/
instruction.
⇒ Ensure correct syntax and format are used.
Example: “HERE point1” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0115
Illegal function.
Occurs when functions are used to assign values to variables, but the data is incompat-
ible.
Example: “POINT #a=SQRT(y)” returns an error.
⇒ Ensure function is compatible with variables.
Example: “x=SQRT (y)” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0116
Illegal argument of function.
Function parameter does not comply with AS Language syntax.
Example: “x=SQRT” returns and error.
⇒ Use correct syntax and format for functions and arguments.
Example: “x=SQRT(3)” is correct and does not return and error.
_____________________________________________________________________
August 9, 2005
1-161
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0117
Invalid variable (or program) name.
Displayed when illegal variable or program name is entered from the editor or monitor
modes.
Example: “JM ##a” too many precision point symbols.
Example: “CALL #a” is not an acceptable program name.
⇒ Ensure program names and variables are defined correctly.
_____________________________________________________________________
ERROR CODE P0118
Illegal variable type.
Displayed when illegal variable is entered from editor or monitor modes.
Example: “b = #a + b” cannot combine location and real variables using an arithmetic
operator.
⇒ Use compatible variable type for commands or instructions.
_____________________________________________________________________
ERROR CODE P0119
incorrect array suffix.
Main causes include:
1. An array is entered that does not comply with AS Language syntax or array format.
Example: “point[1.2.]=1” returns an error.
2. A previously defined variable or array name is used to define a new array name.
Example: “HERE a” is entered then “HERE a[1]” is entered. An error is returned
because location variable “a” is already used.
⇒ Enter the array in compliance with AS Language syntax and array format.
Example: “point[1.2]=1” is correct and does not return an error.
⇒ Change the previously defined variable name.
_____________________________________________________________________
ERROR CODE P0120
Incongruent num. parenthesis.
Occurs when parentheses are not entered as a pair, containing both a left and right
parenthesis.
⇒ Enter parentheses in left and right pairs.
_____________________________________________________________________
1-162
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0121
Expected to be a binary operator.
A non-binary operator has been entered where a command expected a binary operator.
⇒ Enter a binary operator.
_____________________________________________________________________
ERROR CODE P0122
Illegal constant.
A variable, or a non-constant, is used where a constant or integer should be used with a
monitor command.
Example: “WHERE a” Should be WHERE 1 … WHERE 6.
⇒ Use the proper constant or integer with the command. See the D Series Controller
AS Language Reference Manual for more information.
_____________________________________________________________________
ERROR CODE P0123
Illegal qualifier.
Displayed when monitor commands are followed by unexpected qualifiers.
Example: “LIST W” expected characters include P, L, and R for program, location, and
real variables; “W” causes error.
⇒ Enter qualifiers in compliance with AS Language syntax and format.
_____________________________________________________________________
ERROR CODE P0124
Invalid label.
Occurs in the editor mode when a GOTO instruction is combined with a reserved char-
acter.
Example: “GOTO #a” returns an error because “#” is a reserved character.
⇒ Do not use reserved characters in label identification.
_____________________________________________________________________
ERROR CODE P0125
Missing expected character.
Occurs when commands or instructions are entered with an incorrect format.
Example: “TOOL a=b”, “=b” causes an error, “TOOL a” would be correct.
⇒ Use correct syntax and format for commands and instructions.
_____________________________________________________________________
August 9, 2005
1-163
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0126
Illegal switch name.
Displayed when a system switch is incorrectly identified.
Example: “SWITCH light” there is no system switch named “light”.
⇒ Use valid switch names.
_____________________________________________________________________
ERROR CODE P0127
Specified switch name needs full spelling.
System switch name entered does not comply with AS Language syntax.
Example: “SWITCH ERR” returns an error.
⇒ Use system switch names in compliance with AS Language syntax.
Example: “SWITCH ERROR” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0128
Illegal format specifier.
Occurs when the TYPE or PRINT command is not used with an acceptable format
portion of the instruction.
Example: “PRINT/A” returns an error
⇒ Use only specified format instructions with TYPE and PRINT commands.
Example: “PRINT/D” is correct and does not return an error
_____________________________________________________________________
ERROR CODE P0129
Duplicate statement label.
Main causes include:
1. A previously used label is used the second time in the same program.
2. When transferring or copying a program, the same label name is used in the source
and destination programs.
⇒ Use label names only once per program.
_____________________________________________________________________
ERROR CODE P0130
Cannot define as array.
A program name is assigned as an array variable.
Example: “EDIT test[1]” returns an error.
⇒ Enter program names in compliance with AS Language syntax and format.
Example: “EDIT test1” is correct and does not return an error.
_____________________________________________________________________
1-164
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0131
No. of dimension in array exceeds 3.
Attempted to create an array variable with more than 3 dimensions.
Example: “point[3,5,7,9]=1” returns an error.
⇒ Use 3 or less dimensions (elements) in an array.
Example: “point[1,2,3]=1” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0132
Array variable already exists.
Attempted to create an array variable with a different number of dimensions (elements)
with the same name as an existing array variable .
Example: If array variable “test[1]” exists, an array variable “test[1,2]” cannot be defined.
⇒ Confirm array variable exists. Select new name for the array variable with a different
number of dimensions (elements).
Example: “sample[1,2]”
_____________________________________________________________________
ERROR CODE P0133
Non array variable exists.
Attempted to create an array variable with the same name as an existing real variable.
Example: “x=1” is entered, then “y=x[1]” is entered and an error is returned because
real variable “x” already exists.
⇒ Confirm real variable exists. Select new name for array variable.
_____________________________________________________________________
ERROR CODE P0134
Array variable expected.
A real value array name is not used as the array variable for a DECOMPOSE
instruction.
Example: “DECOMPOSE x=point” returns an error.
⇒ Enter real value array name in compliance with AS Language syntax and format.
Example: “DECOMPOSE x[1]=point” is correct and an error is not returned.
_____________________________________________________________________
August 9, 2005
1-165
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0135
Local variable expected.
A global variable is used when defining a temporary argument for a subroutine.
Example: “SUB(a)” returns an error.
⇒ Use a local variable when defining a temporary argument for a subroutine.
Example: “SUB(.a)” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0136
Unexpected suffix.
An array with a suffix is used when defining a temporary argument for a subroutine.
Example: “sub(.a[3])” returns an error.
⇒ Enter the temporary argument in compliance with AS Language syntax and format.
Example: “sub.a” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0137
Mismatch of arguments at subroutine call.
The number of arguments between the source program and the destination program do
not match.
Example: Source: “SUB(.a)”; Destination: “SUB(.a,b)” returns an error.
⇒ Ensure the number of arguments between the source program and the destination
program match.
_____________________________________________________________________
ERROR CODE P0138
Mismatch of argument type at subroutine call.
At a subroutine call, the type of real value argument is different than the type of tempo-
rary argument defined.
Example: “CALL sub(1)” returns an error.
⇒ Correct the type of the argument in the called program or origin program.
Example: “CALL sub1” is correct and does not return an error.
_____________________________________________________________________
1-166
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0139
Illegal control structure.
Main causes include:
1. In a control structure CASE is the last step, or VALUE, END, or ANY are missing after
CASE.
2. Destination step for structure instruction is missing.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0140
Step:XX Wrong END statement.
Occurs when an illegal END statement is entered during editing.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0141
Step:XX Extra END statement.
Occurs when an extra END statement is present and there is no corresponding struc-
ture.
⇒ Use correct syntax and components in control flow structures, check structure of END
statements.
_____________________________________________________________________
ERROR CODE P0142
Step:XX Cannot terminate DO with END.
This error is displayed when the control flow structure DO….UNTIL is entered with an
END statement.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0143
Step:XX No VALUE statement after CASE.
Occurs when the control flow structure CASE OF….END is entered without a value to
evaluate.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
August 9, 2005
1-167
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0144
Step:XX Preceding IF missing.
Displayed when control flow structure does not contain the correct structure for
IF…THEN… ELSE…END commands.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0145
Step:XX Preceding CASE missing.
Displayed when control flow structure does not contain the correct structure for
CASE…OF… VALUE…ANY…END commands.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0146
Step:XX Preceding DO missing.
Displayed when control flow structure does not contain the correct structure for
DO…UNTIL.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0147
Step:XX Cannot find END of XX.
Occurs when control flow structure that requires an END statement does not contain the
necessary END.
⇒ Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0148
Step:XX Too many control structures.
Occurs when 10 layers of control flow structure are exceeded.
⇒ Limit control flow structure to 10 layers.
_____________________________________________________________________
1-168
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0149
Variable (or program) already exists.
The name of a program, loaded from floppy disk or PC card using the LOAD command,
already exists in the system memory. This error is not used in the spot welding applica-
tion.
⇒ Change the name of the program currently in system memory.
⇒ Delete the program in system memory, if not needed.
_____________________________________________________________________
ERROR CODE P0150
Variable of different type already exists.
Displayed when a variable is entered that is already in the system memory.
Example: A location named “weld1” is entered when a program named “weld1” is al-
ready in the memory.
⇒ Do not use variable names for more than one item.
_____________________________________________________________________
ERROR CODE P0151
Internal buffer over due to complicated expression.
Main causes include:
1. An expression is entered that is too complicated.
2. Too many arguments for a command/instruction.
Example: “LIST/PPPPPP” returns an error.
3. More than twenty six arguments are specified in one subroutine.
⇒ Rewrite to reduce the complexity of the expression.
⇒ Ensure the argument for the command/instruction is correct.
Example: “LIST/P” is correct and does not return an error.
⇒ Do not use more than twenty six arguments in a subroutine.
_____________________________________________________________________
ERROR CODE P0152
Undefined Variable (or program).
Attempt to call a subroutine, or process a variable, that does not exist.
Example: “LIST/P test” is entered, but program test does not exist.
⇒ Verify the variable or program exists.
_____________________________________________________________________
August 9, 2005
1-169
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0153
Illegal clock value.
Time or date is entered in the wrong format.
⇒ Re-enter the values correctly; time—military, date—yy/mm/dd.
_____________________________________________________________________
ERROR CODE P0154
Missing “=”.
The argument is missing the necessary “=”.
Example: “XFER test sub” returns an error.
⇒ Ensure command/instruction complies with AS Language syntax and format.
Example: “XFER test=sub” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0155
Missing “)”.
The argument is missing the necessary “)”.
Example: “(.a” returns an error.
⇒ Ensure command/instruction complies with AS Language syntax and format.
Example: “(.a)” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0156
Missing “]”.
The argument is missing the necessary “]”.
Example: “$line[2” returns and error.
⇒ Ensure command/instruction complies with AS Language syntax and format.
Example: “$line[2]” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0157
Missing “TO”.
The argument is missing the necessary “TO”.
Example: “FOR test = 1 max.test” returns an error.
⇒ Ensure command/instruction complies with AS Language syntax and format.
Example: “FOR test = 1 TO max.test” is correct and does not return an error.
_____________________________________________________________________
1-170
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0158
Missing “BY”.
The argument is missing the necessary “BY”.
Example: “POINT y = SHIFT (x 5,5,5)
⇒ Ensure command/instruction complies with AS Language syntax and format.
Example: “POINT y = SHIFT (x BY 5,5,5)
_____________________________________________________________________
ERROR CODE P0159
Missing “:”.
The argument is missing the necessary “:”.
Example: “SEND 1 $out,err” returns an error.
⇒ Ensure command/instruction complies with AS Language syntax and format.
Example: “SEND 1: $out,err” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0160
Specify ”ON” or “OFF”.
The command/instruction does not comply with AS Language syntax or format.
Example: “TRACE 1 ON” returns an error.
⇒ Ensure command/instruction complies with AS Language syntax and format.
Example: “TRACE 1:ON” is correct and does not return an error.
_____________________________________________________________________
ERROR CODE P0161
Robot num. must be specified.
This error occurs when the robot number is omitted from the syntax of an AS Language
command which requires the robot number as an argument.
Example: “HERE P” returns an error.
⇒ Include the robot number as an argument as required.
Example: “HERE 1: P” is correct and does not return an error.
_____________________________________________________________________
August 9, 2005
1-171
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P0162
Cannot modify position data in this instruction.
During modifying an AS Language program from the teach screen, pose data is modi-
fied at a step with a non-positional command/instruction.
Example: Trying to modify pose data, at a step with “DELAY 1” recorded, returns an
error.
⇒ Pose data can only be modified for AS Language program steps containing move
instructions (JMOVE, LMOVE, etc.).
_____________________________________________________________________
ERROR CODE P1000
Cannot execute program because motor power is OFF.
Program will not start because motor power is not ON.
⇒ Set motor power ON.
⇒ Select repeat mode.
⇒ Set teach lock OFF.
⇒ Re-execute program.
_____________________________________________________________________
ERROR CODE P1001
Cannot execute program in TEACH mode.
Programs cannot run in teach mode.
⇒ Ensure that the controller is in REPEAT mode.
⇒ Defective TEACH/REPEAT switch.
⇒ Defective 1KA board.
_____________________________________________________________________
ERROR CODE P1002
Cannot execute program because teach lock is ON.
Programs cannot run with the teach lock in the ON position.
⇒ Set the TEACH LOCK switch OFF and execute the program again in repeat mode.
⇒ Defective teach pendant or 1KA board.
_____________________________________________________________________
1-172
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1003
Cannot execute a program because of EXT.HOLD input.
An attempt to cycle start a program is made while external hold signal is ON.
⇒ Release the external hold and re-execute cycle start.
⇒ Verify dedicated input signals in AUX 0601 match signals programed from the PLC in
the Slogic program.
⇒ If the external hold signal is not needed, change the signal setting in AUX 0601 from
set to reset.
NOTE
With cycle start switch set OFF in AUX 0502, cycle start
is kept ON if external hold is applied; program execution
resumes once external hold is released.
_____________________________________________________________________
ERROR CODE P1004
Cannot execute program being reset.
This error occurs when a cycle start signal is received during a program reset.
⇒ Adjust the timing of the program reset and the cycle start signals.
_____________________________________________________________________
ERROR CODE P1006
Cannot execute program because of EXT.START DIS-
ABLE.
This error occurs when the external cycle start signal is received with the EXT.START
dedicated signal OFF.
⇒ Release the EXT.START dedicated signal in AUX. 0601 Dedicated Input Signal.
⇒ The EXT.START dedicated signal must be ON when the external cycle start signal is
received.
⇒ Use the external cycle start dedicated input signal to execute the robot program.
_____________________________________________________________________
August 9, 2005
1-173
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1009
Program is already running.
Main causes include:
1. An attempt is made to edit or execute a program that is running.
2. SYSINIT command is executed while a program is running.
⇒ Stop the robot control program prior to editing or checking.
⇒ Stop the robot control program prior to executing the SYSINIT command.
_____________________________________________________________________
ERROR CODE P1010
Robot control program is already running.
Occurs when an attempt is made to execute a DO, TOOL, or BASE command when a
robot control program is running.
⇒ Wait for the robot control program to complete execution.
⇒ Stop the robot control program.
_____________________________________________________________________
ERROR CODE P1011
Cannot continue this program. Use EXECUTE.
After a program is executed the specified number of times in repeat mode, the CON-
TINUE command is entered or the CYCLE START switch is pressed.
⇒ The CONTINUE command or CYCLE START switch cannot be used at this time, use
the EXECUTE command to start the program.
⇒ Re-select the program and press the CYCLE START switch.
_____________________________________________________________________
ERROR CODE P1012
Robot is moving now.
Displayed if any of the following commands are entered while a program is running:
EXECUTE, CONTINUE, TOOL, BASE, DO. SYSINIT or CYCLE START.
⇒ Stop the program or confirm the operation to be performed.
_____________________________________________________________________
ERROR CODE P1013
Cannot execute because in error now. Reset error.
Occurs when attempt is made to start robot motion before an error has been cleared.
⇒ Clear any errors and re-enter the command.
_____________________________________________________________________
1-174
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1014
Cannot execute because program already in use.
An attempt to execute the same program using the EXECUTE and PCEXECUTE is
made.
⇒ Allow the program to complete executing and re-execute.
_____________________________________________________________________
ERROR CODE P1015
Cannot delete, in use by another command.
Cannot COPY, DELETE or XFER command because program is being edited or ex-
ecuted.
⇒ Complete program editing before using COPY, DELETE or XFER commands.
⇒ Allow program execution to complete before using COPY, DELETE or XFER com-
mands.
_____________________________________________________________________
ERROR CODE P1016
Cannot delete, used in program.
An attempt is made to delete a variable that is used in a program.
⇒ Deletion of variables used in programs is not allowed by the AS system.
_____________________________________________________________________
ERROR CODE P1017
Cannot delete a program in Editor.
Attempting to delete a program that is open in editor mode.
⇒ Exit editor mode, and then delete the selected program.
_____________________________________________________________________
ERROR CODE P1018
KILL or PCKILL to delete program.
Occurs when an attempting to delete a program that is still on the stack (selected).
⇒ Select another program or KILL/PC KILL the program, then delete.
_____________________________________________________________________
August 9, 2005
1-175
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1019
PC program is running.
Occurs when a PC program is running and instructions are entered that are not allowed.
⇒ Allow the PC program to complete execution and re-enter the instructions.
⇒ Stop the PC program and re-enter the instruction.
_____________________________________________________________________
ERROR CODE P1020
Cannot operate because teach pendant in operation.
Functions cannot be performed on the personal computer while the teach pendant is in
use.
⇒ Perform functions on the PC after the teach pendant operation is completed.
_____________________________________________________________________
ERROR CODE P1021
Cannot execute with DO command.
Displayed when the DO command is entered with an instruction that does not comply
with AS Language syntax.
⇒ Ensure command/instruction is in compliance with AS Language syntax and format.
_____________________________________________________________________
ERROR CODE P1022
Cannot execute with MC instruction.
An improper MC instruction is entered.
Example: MC DO HOME.
⇒ The MC instruction is used with ABORT, CONTINUE, ERESET, EXECUTE, HOLD,
and SPEED only.
_____________________________________________________________________
ERROR CODE P1023
Cannot execute in Robot program.
MC or PCSCAN instruction is used in a robot program.
⇒ MC or PCSCAN instructions are used in a PC programs only.
_____________________________________________________________________
1-176
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1024
Statement cannot be executed.
Occurs when the AS Language instruction entered is not acceptable for the mode of
operation.
Example: DO HOME is executed with TEACH LOCK ON.
⇒ Use instructions and commands that are compatible with the selected mode.
_____________________________________________________________________
ERROR CODE P1025
Cannot be executed, function not set.
An attempt is made to use a function that is not installed or set-up.
Example: Communication with 1GV board with data communication or I/O communica-
tion disabled.
⇒ To add a function that is not set-up or installed contact KRI customer service.
Example: For the above example, enable data communication or I/O communication.
_____________________________________________________________________
ERROR CODE P1026
Can’t KILL program that is running.
Displayed when an attempt is made to KILL a program that is executing.
⇒ Stop program execution with HOLD or ABORT commands before program is removed
from the stack with a KILL command.
_____________________________________________________________________
ERROR CODE P1027
Cannot edit program, TEACH LOCK is ON.
Programs cannot be edited if the TEACH LOCK switch is ON.
⇒ Turn TEACH LOCK switch OFF.
_____________________________________________________________________
ERROR CODE P1028
Cannot paste.
Occurs when the operator is executing the paste function and no data is stored in the
paste buffer or the step(s) cannot be overwritten.
⇒ Ensure steps are copied before paste operation is executed.
⇒ Ensure insertion point is correct or steps can be overwritten.
_____________________________________________________________________
August 9, 2005
1-177
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1029
Program name not specified.
Displayed when no program is on the stack and the EDIT command is entered without
specifying a program name.
⇒ Specify the name of the program to edited.
_____________________________________________________________________
ERROR CODE P1030
Program interlocked by other procedure.
The selected program is not recognized as a robot program or a PC program and is
used by another part of the software.
⇒ Initialize the system and reload the program.
_____________________________________________________________________
ERROR CODE P1031
No free memory.
Main causes include:
1. Not enough free memory to edit or teach a program.
2. Too many paths registered for arc welding (900 paths allowed in database).
⇒ Delete unused programs and variables, or, expand system memory to maintain the
required capacity.
⇒ Store 900 or less arc welding paths in database.
_____________________________________________________________________
ERROR CODE P1032
No program step.
The step specified for execution or copying does not exist in program.
⇒ Select valid steps for execution.
⇒ Create step(s) in the program.
_____________________________________________________________________
ERROR CODE P1033
Program name already exists.
When using the RENAME or COPY command a new program name must be specified.
If an existing name is used this error is displayed.
⇒ Specify unused program names when renaming or copying programs.
⇒ If not needed, delete the existing program with the name used.
_____________________________________________________________________
1-178
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1034
This program is not editable.
The auto load measurement program cannot be edited.
⇒ Use a program name that does not include the auto load measurement program
name.
_____________________________________________________________________
ERROR CODE P1035
Record inhibited. Set [record accept] and operate again.
Displayed when an attempt is made to enter data, but Inhibit Record in auxiliary function
0802 is set to inhibit.
⇒ Change the setting of the Inhibit Record in AUX 0802.
_____________________________________________________________________
ERROR CODE P1036
Program change inhibited. Set [Accept] and operate
again.
Displayed when an attempt is made to enter data, but Program Change in auxiliary
function 0802 is set to inhibit.
⇒ Change the setting of the Program Change in AUX 0802.
_____________________________________________________________________
ERROR CODE P1037
Program name cannot be called “calib_load_”.
⇒ Use a program name that does not include “calib_load_“.
_____________________________________________________________________
ERROR CODE P1038
Program does not exist.
Main causes include:
1. Non-existing program is selected.
2. Program check operation or cycle start is executed without a program selected.
⇒ Select an existing program before executing program check or cycle start.
_____________________________________________________________________
August 9, 2005
1-179
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P1039
Teach pendant is not connected.
The “T” command is executed without the teach pendant connected.
⇒ Install teach pendant and re-execute the “T” command.
_____________________________________________________________________
ERROR CODE P1040
Cannot execute this command in I/F panel.
A monitor-command button is set-up on the I/F panel to execute a command that is not
permitted from the I/F panel. When the monitor-command button is pressed this error is
displayed.
⇒ Use commands permitted for I/F panel use.
_____________________________________________________________________
ERROR CODE P1041
Auto monitor command failure.
An error occurrs when a command specified for the auto monitor command function is
executed.
⇒ Use the error cause stored in the error log as a troubleshooting aid.
_____________________________________________________________________
ERROR CODE P1042
NUM program is running.
This error occurs when the NUM program is executed and the NUM program is already
running.
⇒ Allow the current program execution to complete before re-executing.
_____________________________________________________________________
ERROR CODE P1043
Cannot execute in REPEAT mode.
Teach mode function is attempted in repeat mode.
⇒ Ensure teach mode is selected when executing teach mode functions.
_____________________________________________________________________
ERROR CODE P1044
Cannot execute on because motor power is ON.
An attempt is made to enable motion verification mode while motor power is ON.
⇒ Set motor power OFF and re-execute.
_____________________________________________________________________
1-180
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2000
Turn OFF motor power.
An attempt is made to execute an operation or command which is not permitted with
motor power ON.
Example: ZZERO command.
⇒ Turn motor power OFF and re-execute operation or command.
_____________________________________________________________________
ERROR CODE P2001
Turn HOLD/RUN sw. to HOLD.
Occurs when an attempt to execute DO, STEP, MSTEP, CONTINUE, or EXECUTE
command is made with the RUN/HOLD switch in the RUN position. Only applies if the
CHECK.HOLD system switch is ON (AUX 0502).
⇒ Turn the RUN/HOLD switch to HOLD position.
_____________________________________________________________________
ERROR CODE P2002
There is no external axis.
External axis cooperative motion command is executed and external axis equipment is
not installed.
⇒ Enable option or contact customer service to install external axis option.
_____________________________________________________________________
ERROR CODE P2003
Illegal positioner type.
An out of range value is used to specify the type of positioner for an external axis.
⇒ Specify the positioner type with a value that is in range.
_____________________________________________________________________
ERROR CODE P2004
Cannot change, user data already exist.
An attempt is made to change system data (number of axes, etc.) without deleting
existing user data.
⇒ Save user data to PC card or floppy disk and delete user data from system memory.
Change system data and reload user data from PC card or floppy disk.
_____________________________________________________________________
August 9, 2005
1-181
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2006
Option is OFF.
Selected option is set OFF (disabled) or is not installed.
⇒ Enable option or contact KRI customer service to install option.
_____________________________________________________________________
ERROR CODE P2007
Cannot execute because executed by other device.
Occurs when the operator attempts to execute the same command from the KCWIN
terminal and the teach pendant at the same time.
⇒ Cannot execute commands from two devices at the same time.
_____________________________________________________________________
ERROR CODE P2008
Device is not ready.
This error occurs when the RS232C communication port is configured to be used with a
PC and Host Communication (I) communication is attempted.
⇒ Use the AS Language TERMOFF command to reconfigure the communication proto-
col.
_____________________________________________________________________
ERROR CODE P2009
Illegal file name.
This error occurs when a file name does not follow to the proper syntax during file save
or load.
⇒ The first character in a file name must be alphabetic.
⇒ File names are limited to eight characters (excluding three character extension).
⇒ File names cannot contain spaces.
_____________________________________________________________________
ERROR CODE P2010
Disk is not ready.
This error occurs when a floppy disk is not installed or is not readable.
⇒ Ensure the floppy disk is properly installed in the drive unit.
⇒ Ensure the floppy disk is not write protected.
⇒ Defective floppy drive unit or defective 1KA board.
⇒ Defective local bus harness.
_____________________________________________________________________
1-182
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2011
Invalid disk format.
Incorrect disk format.
⇒ Ensure the disk format is: 2HD, 1.44 MB or 1.25 MB.
_____________________________________________________________________
ERROR CODE P2012
Disk is write protected.
This error occurs when attempting to write to a disk that is write protected.
⇒ Disable the write protection on the floppy disk card.
⇒ Defective floppy disk, floppy disk drive unit, or defective 1KA board.
⇒ Defective local bus harness.
_____________________________________________________________________
ERROR CODE P2013
Disk full.
This error occurs when attempting to write to a floppy disk that does not have enough
free space to complete a save.
⇒ Disable the write protection on the floppy disk.
⇒ Use a floppy disk with free space available.
⇒ Defective floppy disk, floppy disk drive unit, or defective 1KA board.
_____________________________________________________________________
ERROR CODE P2014
Too many files.
This error occurs when the number of files on the floppy disk, or PC card, exceeds the
maximum.
⇒ Use a floppy disk with available free space.
⇒ Defective floppy disk, floppy disk drive unit, or defective 1KA board.
⇒ Defective local bus harness.
_____________________________________________________________________
ERROR CODE P2015
Cannot write on read-only file.
An attempt is made to overwrite or delete a read-only file on a floppy disk or PC card.
⇒ Change the file properties.
_____________________________________________________________________
August 9, 2005
1-183
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2016
Cannot open the file.
The file cannot be opened with the SAVE or LOAD commands.
⇒ Ensure the floppy disk is properly inserted into the floppy disk drive.
⇒ Ensure an existing file name is used.
⇒ Defective local bus harness.
⇒ Defective floppy disk, floppy disk drive unit, or 1KA board.
_____________________________________________________________________
ERROR CODE P2017
Cannot close the file.
A file opened by the SAVE or LOAD command cannot be closed.
⇒ If the file is opened using a PC, ensure proper connection with the controller.
⇒ Defective local bus harness.
⇒ Defective floppy disk, floppy disk drive unit, or 1KA board.
_____________________________________________________________________
ERROR CODE P2019
ADC function already in use.
This error occurs when a monitor command and a program command are executed for
an ADC function at the same time.
⇒ Do not execute a monitor command for an ADC function while a robot or process
control program is executing an ADC function command.
_____________________________________________________________________
ERROR CODE P2020
Illegal device number.
For Host Communication I, the sensor port is specified as logical device number 1 or 7.
The PC terminal port is specified as logical device number 2 or 8. This error occurs
when a SEND command/instruction specifies an illegal device number.
Example: SEND 3:$out,err.
⇒ Ensure an available device number is specified.
Example: SEND 1:$out,err.
_____________________________________________________________________
1-184
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2022
Cannot use DOUBLE OX.
When DOUBLE type signals are used, if either output signal in the pair is set ON, the
other is set to OFF. An instruction (BITS, PULSE, DLYSIG, etc.) to change the state of
either output signal causes this error to occur.
⇒ Ensure signals used with the BITS, PULSE, DLYSIG, etc. commands/instructions are
not designated as DOUBLE OX.
_____________________________________________________________________
ERROR CODE P2023
In cooperative mode.
Main causes include:
1. An EXECUTE, DO, PRIME, or PRESET command, or, a program selection, step
selection, or external program reset command is executed during cooperative motion.
2. MASTER or SLAVE instruction is executed between MASTER and ALONE instruc-
tions in the MASTER robot program, or between SLAVE and ALONE instructions in
the SLAVE robot program.
⇒ Do not use EXECUTE, DO, PRIME or PRESET commands or program select, step
select, or external program reset command during cooperative motion.
⇒ Correct the MASTER or SLAVE robot program as needed.
_____________________________________________________________________
ERROR CODE P2024
Invalid coordinate value X.
This error occurs when the work space output signal lower X value is greater than the
upper value in AUX 0403.
⇒ Ensure upper and lower values are set correctly in AUX 0403.
_____________________________________________________________________
ERROR CODE P2025
Invalid coordinate value Y.
This error occurs when the work space output signal lower Y value is greater than the
upper value in AUX 0403.
⇒ Ensure upper and lower values are set correctly in AUX 0403.
_____________________________________________________________________
August 9, 2005
1-185
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2026
Invalid coordinate value Z.
This error occurs when the work space output signal lower Z value is greater than the
upper value in AUX 0403.
⇒ Ensure upper and lower values are set correctly in AUX 0403.
_____________________________________________________________________
ERROR CODE P2027
Cannot use signal, already used in I/F panel.
This error occurs when a signal allocated for the I/F panel is used as an OX signal.
⇒ Use a signal that is not allocated for the I/F panel.
_____________________________________________________________________
ERROR CODE P2028
Arm ID board is busy.
This error occurs when the 1GV arm ID board is processing data when a flash memory
access command is executed (MNTREC, MNTLOG, etc.).
⇒ Execute the flash memory access command after the 1GV arm ID board completes
processing the data.
⇒ Defective 1GV arm ID board.
_____________________________________________________________________
ERROR CODE P2029
Axis setting data is incorrect.
The channel number for the external axis is set to a channel number already assigned
to another axis in AUX 2001, External Axis Set.
⇒ Ensure the correct channel number is set in AUX 2001 using the values from the
original factory specification sheet.
_____________________________________________________________________
ERROR CODE P2031
Deleted step was destination of Jump, Call instruction.
This error occurs when the destination step for a JUMP or CALL instruction specified by
FN20, FN23, or FN26 is deleted.
⇒ Teach a step at the JUMP destination.
⇒ Ensure the correct step is designated in FN20, FN23, or FN26.
_____________________________________________________________________
1-186
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2032
Incorrect number input as WHERE parameter.
Occurs if a numeric value entered with the WHERE command is not in the acceptable
range.
Example: WHERE 100.
⇒ Ensure that data is within acceptable range.
Example: WHERE 1.
_____________________________________________________________________
ERROR CODE P2033
Logging is running.
This error occurs when a robot program or a PC program executes the SETTRACE or
RESTRACE commands during LSTRACE command execution.
⇒ Execute SETTRACE or RESTRACE after logging is completed.
⇒ Turn off trace functions in all robot and PC programs.
_____________________________________________________________________
ERROR CODE P2034
Undefined memory.
This error occurs when the TRACE ON command is executed before securing the
memory address with the SETTRACE command.
⇒ Secure the memory address with the SETTRACE command.
_____________________________________________________________________
ERROR CODE P2035
Non data.
This error occurs when the ZMNTCLEAR instruction is executed for a number of mainte-
nance log entries greater than the number of entries in the maintenance log.
⇒ Use the MNTLOG command or AUX 123-2 to display and confirm the number of
maintenance log entries.
_____________________________________________________________________
ERROR CODE P2038
Matrix Calculation Error.
An error occurred in a software calculation.
Example: The three points for creating an arc path are on the same line in the CSHIFT
function.
⇒ Make necessary corrections and recalculate value.
_____________________________________________________________________
August 9, 2005
1-187
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2039
Cannot start cycle from FN instruction.
This error occurs when an FN instruction is the first step at cycle start.
⇒ Do not execute cycle start at a step containing an FN instruction.
_____________________________________________________________________
ERROR CODE P2040
Card is not ready.
The controller tried to read the PC card, but the PC card is not inserted.
⇒ Insert PC card and re-execute.
_____________________________________________________________________
ERROR CODE P2041
Wrong card loaded.
The PC card inserted in the controller cannot be used or is defective.
⇒ Insert a usable PC card.
_____________________________________________________________________
ERROR CODE P2042
Card is write-protected.
An attempt is made to overwrite or delete data on a PC card that is write-protected.
⇒ Remove write-protection and re-execute.
_____________________________________________________________________
ERROR CODE P2043
Card battery is low voltage.
An attempt is made to access a PC card with low battery voltage.
⇒ Replace card battery and re-execute.
_____________________________________________________________________
ERROR CODE P2044
Card is not formatted.
An attempt is made to access a PC card that is not formatted.
⇒ Insert a formatted PC card.
⇒ Use AUX 0204 to format the SRAM PC card.
_____________________________________________________________________
1-188
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2045
Cannot format this card.
An attempt is made to format a non-SRAM PC card.
⇒ Use a PC to format a non-SRAM card.
_____________________________________________________________________
ERROR CODE P2046
Card initialization error.
PC card format failed.
⇒ Re-execute PC card format.
⇒ If the error recurs, use another PC card.
_____________________________________________________________________
ERROR CODE P2047
File is already open.
An attempt is made to open a file that is already open.
⇒ Cycle controller power OFF and ON and re-execute.
⇒ If this error recurs, replace the 1KA/1KF boards or harness.
_____________________________________________________________________
ERROR CODE P2048
File does not exist in card.
Non-existing file is specified for loading or deleting from a PC card.
⇒ Ensure an existing file name is used.
_____________________________________________________________________
ERROR CODE P2049
Attempted to open too many files.
An attempt is made to open a file while another file is open.
⇒ Cycle controller power OFF and ON and re-execute.
⇒ If this error recurs, replace the 1KA/1KF boards or harness.
_____________________________________________________________________
ERROR CODE P2050
Unexpected error during card access.
An unregistered error occurred.
⇒ Cycle controller power OFF and ON and re-execute.
⇒ If this error recurs, replace the PC card, 1KA/1KF boards, or harness.
_____________________________________________________________________
August 9, 2005
1-189
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2051
Illegal sequence numbers for file I/O data.
During data transfer between the 1KA and 1KF boards, the response from the 1KF
board does not conform to the request from the 1KA board.
⇒ Replace the 1KA/1KF boards.
⇒ Replace the harness between the 1KA and 1KF boards.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE P2052
[LSEQ] Program includes unavailable instructions.
An unavailable instruction is included in basic operation part of the KLogic program
(lsqpg).
Example: JMOVE.
⇒ Delete unavailable instruction form the KLogic program (lsqpg).
_____________________________________________________________________
ERROR CODE P2053
[LSEQ] Too many steps exist.
An excessive number of steps exist in the basic operation part of the KLogic program
(lsqpg).
⇒ Correct the KLogic program so the number of steps does not exceed the maximum
number of steps allowed (10,000 steps maximum).
_____________________________________________________________________
ERROR CODE P2054
[LSEQ] Invalid type of signal variable.
An instruction that specifies an invalid signal variable as an argument is used in the
basic operation part of the KLogic program.
Example: LSQ OUT,&X0000.
⇒ Ensure a valid signal variable is used in the KLogic program.
Example: LSQ OUT,&Y0000.
_____________________________________________________________________
1-190
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2055
[LSEQ] Program is already running.
During execution of the basic operation part of the sequence function of the KLogic
program, the program is executed again by the LSQEXECUTE command/instruction.
⇒ Place the basic operation part of the sequence function in HOLD and re-execute.
⇒ Correct the currently running program using the LSQREWRITE command.
_____________________________________________________________________
ERROR CODE P2056
[LSEQ] No. of signal is outside specifiable range.
The basic operation part of the KLogic program includes an instruction that specifies an
invalid signal number as an argument.
Example: LSQ STR, &X0800.
⇒ Ensure valid signal numbers are used in the KLogic program.
Example: LSQ STR,&X07FF.
_____________________________________________________________________
ERROR CODE P2057
[SerialFlash] cannot open file.
A file stored on the 1KA board cannot be opened.
Main cases include:
1. The file is corrupt.
2. An attempt to save is made, but the 1KA board serial flash memory is set to write-
protect.
⇒ Ensure the 1KA board serial flash memory is not set to write-protect.
⇒ Replace the 1KA board serial flash memory.
_____________________________________________________________________
ERROR CODE P2058
[SerialFlash] data read error.
A file on the 1KA board cannot be read because the file is corrupt.
⇒ Replace the 1KA board serial flash memory.
_____________________________________________________________________
August 9, 2005
1-191
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2059
[SerialFlash] data write error.
The specified file cannot be written to the 1KA board.
Main causes include:
1. The file is corrupt.
2. The serial flash memory on the 1KA board is set to write-protect.
⇒ Ensure the 1KA board serial flash memory is not set to write-protect.
⇒ Replace the 1KA board serial flash memory.
_____________________________________________________________________
ERROR CODE P2060
[SerialFlash] File or directory doesn’t exist.
The specified file or directory does not exist in the serial flash memory on the 1KA
board.
⇒ Ensure the file or directory exists in the serial flash memory.
⇒ Create a new file or directory.
_____________________________________________________________________
ERROR CODE P2061
File does not exist in floppy.
When accessing the floppy disk, the specified file cannot be found on the floppy disk.
⇒ Ensure an existing file name is specified.
_____________________________________________________________________
ERROR CODE P2062
[FDD/PC_CARD] Failure in writing data per verify function.
When the verify function is enabled in AUX 0208, the destination and source data are
compared when writing data to a floppy disk or PC card. This error occurs if the data
does not match.
⇒ Replace the floppy disk/PC card.
⇒ If this error recurs, replace the 1KA/1KF boards or harness.
_____________________________________________________________________
ERROR CODE P2063
[FDD/PC_CARD] Faulty response from verify function.
Setting enable or disable for the verify function in AUX 0208 failed.
⇒ Re-execute.
⇒ If this error recurs, replace the 1KF board.
_____________________________________________________________________
1-192
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2064
[FDD] No space available.
Floppy disk has less than 12 KB of free space and the data cannot be saved.
⇒ Insert a floppy disk with sufficient free space and re-execute.
⇒ Delete unnecessary data from the floppy disk and re-execute.
_____________________________________________________________________
ERROR CODE P2065
[Multi Disks] Invalid disk was loaded.
When loading data that is saved to several floppy disks, the data on the currently in-
serted floppy disk does not follow the data previously loaded.
⇒ Use a PC to verify data on disk.
⇒ Ensure data is loaded in the order it is saved.
_____________________________________________________________________
ERROR CODE P2066
Boot flash state is write-disenable.
Attempting to rewrite the contents of the boot flash memory.
Example: Rewriting the MAC address.
⇒ Boot flash memory is write-protected.
_____________________________________________________________________
ERROR CODE P2067
[Serial Flash] File directory error.
Specified directory exists, but cannot be read due to abnormality.
Example: Error when accessing the serial flash memory.
⇒ Replace the serial flash memory on the 1KA board.
_____________________________________________________________________
ERROR CODE P2068
Cannot execute program being edited now.
An attempt is made, from another monitor, to edit the file currently being edited, or to
CALL the program from another program.
⇒ Complete the program edit and re-execute.
_____________________________________________________________________
August 9, 2005
1-193
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2069
[FDD/PC_CARD] Device already in use.
Attempting to perform several processes at the same time to/from the floppy disk/PC
card. The next task is commanded while the previously commanded task is in progress.
⇒ Allow each task to be completed before initiating another task to/from the floppy disk/
PC card.
_____________________________________________________________________
ERROR CODE P2070
No more data can be registered.
An attempt is made to set additional signal names or comments beyond the maximum
number allowed in the KLogic program.
⇒ Delete unnecessary signal names and comments.
⇒ Initialize all data.
_____________________________________________________________________
ERROR CODE P2071
C/S switch set to disable.
The CYCLE START switch is pressed while the cycle start switch invalid option set ON.
⇒ Set the cycle start switch invalid option OFF and re-execute.
_____________________________________________________________________
ERROR CODE P2072
[LSEQ] Maximum cycles of execution.
While executing the basic operation part of the KLogic program, execution cycle time is
calculated as longer than the cycle time set using the LSQ_CYCMAX (maximum length
of execution cycle) command/instruction. In this case, the program is not executed.
⇒ Reduce the number of steps in the program.
⇒ Increase the maximum execution cycle time (if possible).
_____________________________________________________________________
ERROR CODE P2073
[LSEQ] Other program is waiting execution.
During execution of the basic operation part of the KLogic program, an attempt is made
to execute LSQREWRITE. Overwriting program data using the LSQREWRITE com-
mand/instruction is executed after completing the last step of the currently running
program.
⇒ Allow the current program execution to complete before executing the LSQREWRITE
command/instruction.
_____________________________________________________________________
1-194
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P2074
Floppy disk is broken.
This error occurs when ten or more defective sectors are detected on a floppy disk.
⇒ Use a new or known good floppy disk.
_____________________________________________________________________
ERROR CODE P2075
Channel number of JtXX is incorrect.
Main causes include:
1. Non-existing channel number is allocated.
2. Board for driving Mitsubishi motor is not installed or incorrect board is installed on the
1KB board.
⇒ Ensure the external axis channel number set in AUX 2002 is correct.
⇒ Ensure the correct Mitsubishi motor driving board is installed to the 1KB board.
_____________________________________________________________________
ERROR CODE P4500
FIELD-BUS) Interface not enabled.
Main causes include:
1. An attempt is made to execute the PROFIBUS (/DEVNET) command without register-
ing the appropriate fieldbus interface.
2. The PROFIBUS (/DEVNET) interface card is not installed.
⇒ Ensure the fieldbus interface is registered.
⇒ Ensure the fieldbus interface card is properly installed.
_____________________________________________________________________
ERROR CODE P4501
DEVNET) Node XX not in the scanlist.
An attempt is made to execute the DEVNET command to a slave that is not in the
scanlist.
⇒ Ensure the MAC_ID, settings and parameters for the device to receive the monitor
command are correct and re-execute the DEVNET command.
_____________________________________________________________________
August 9, 2005
1-195
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P4502
DEVNET) Already in that mode.
An attempt is made to change the operation mode setting, using the DEVNET com-
mand, to the mode that is currently set.
⇒ Ensure the correct parameter is set and re-execute the DEVNET command.
_____________________________________________________________________
ERROR CODE P4503
Duplicate signal number.
The specified signal number cannot be used because the same signal number is cur-
rently set.
⇒ Specify a different signal number.
_____________________________________________________________________
ERROR CODE P5000
Waiting weld completion.
Displayed when a command to change the step is entered while a welding sequence is
in progress (weld complete or retract/extend signal not received).
⇒ Reset the error, and release the wait condition.
⇒ Manually input weld complete or retract/extend signal.
_____________________________________________________________________
ERROR CODE P5001
Waiting retract or extend pos. input signal.
One of the following operations is attempted when the robot is processing a spot weld
sequence (waiting for the Retract/Extend signal after the weld complete signal is re-
ceived).
1. Cycle start (including EXECUTE, CONTINUE command).
2. Program selection or step change.
3. Record.
⇒ Input the Retract/Extend detection signal to the robot or access the wait override
screen on the teach pendant. Refer to the D Series Controller Operations and Pro-
gramming Manual for the wait override procedure.
_____________________________________________________________________
1-196
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P5002
Spot sequence is running.
Step change, program change, or program execution attempted while the spot weld
sequence is executing (after Retract/Extend input signal and weld complete signal are
received).
Example: The robot is executing motion start delay time after weld complete.
⇒ Perform step change, program registration or program execution after the spot weld-
ing sequence is complete.
⇒ Reset the error, and release the wait condition.
_____________________________________________________________________
ERROR CODE P5003
External axis type and gun data mismatch.
The servo gun setting does not correspond to the type of external axis (set in AUX
2002) and type of gun (set in AUX 0605-12). This error is detected when motion begins
for a step with a clamp signal set.
⇒ Confirm that the external axis and gun type data settings are correct.
_____________________________________________________________________
ERROR CODE P6000
Shifted location of STEP XX is out of range.
After the shift function is executed, an axis (axes) exceeds motion range.
⇒ Ensure the new pose data after the shift is within motion range.
_____________________________________________________________________
ERROR CODE P6001
Step XX in source program is out of motion range.
Source program pose data is out of motion range in the shift function.
⇒ Ensure the pose data in the source program is within motion range.
_____________________________________________________________________
ERROR CODE P6003
Cannot execute program because of suspend playback.
An attempt is made to cycle start when the dedicated input signal for forced termination
of repeat operation is set OFF.
⇒ Manually input the dedicated signal for forced termination of repeat operation.
_____________________________________________________________________
August 9, 2005
1-197
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P6500
Cannot generate working line direction.
This error occurs when weld start and end points are the same, and motion direction
cannot be determined.
⇒ Ensure the start and end points are not the same.
_____________________________________________________________________
ERROR CODE P6501
Illegal tool posture.
The tool angle (angle between torch and welding line; also called torch angle) is 0 de-
grees and the welding cannot be executed.
⇒ Teach a third point besides the weld start and end points above the line between the
start and end points so that the torch assumes an appropriate angle.
_____________________________________________________________________
ERROR CODE P6502
No weld database.
The arc weld condition database specified by the source program does not exist.
⇒ Create arc weld condition database specified by the program.
_____________________________________________________________________
ERROR CODE P6503
Cannot change weld condition.
An attempt is made to change weld conditions using the real time weld condition modifi-
cation function without selecting check mode and WELD ON.
⇒ To change weld conditions using the real time weld condition modification function.
1. Select check mode.
2. Set WELD ON.
3. Change weld conditions.
_____________________________________________________________________
ERROR CODE P6504
Step:XX Preceding L.START missing.
This error occurs when an L.START instruction does not proceed an L.END instruction.
⇒ Add a step containing an L.START instruction before the step containing the L.END
instruction.
_____________________________________________________________________
1-198
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE P7000
Cannot program reset, because not at home position 1.
The robot is not at the registered home 1 position, and the program reset signal is
ignored.
⇒ Ensure the robot is at the home 1 position, and re-execute.
_____________________________________________________________________
August 9, 2005
1-199
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.3.2.4 WXXXX MECHANICAL/CONTROL WARNING ERROR CODES
ERROR CODE W1000
Cannot move along straight line JTXX in this configuration.
When operating manually in teach mode and in base or tool mode, axis (JTXX) speed
exceeds capability with the wrist in this posture.
⇒ Change the wrist posture.
⇒ Reduce teach speed.
⇒ Reduce repeat speed.
⇒ Change the interpolation mode to joint.
_____________________________________________________________________
ERROR CODE W1001
Over maximum joint speed in check. Set low speed.
Commanded speed for each joint exceeds the allowable value during check operation.
⇒ Reduce check speed, re-execute.
_____________________________________________________________________
ERROR CODE W1002
Operation information was cleared.
The memory area used to store operational information is corrupt.
⇒ Cycle the controller power OFF and ON.
⇒ If this error recurs, replace the 1KA board.
_____________________________________________________________________
ERROR CODE W1003
Calibration failed. Retry after changing posture.
Auto load measurement failed.
⇒ Change the posture of the robot to allow sufficient torque load to be applied to JT3, 5,
and 6 for auto load measurement.
_____________________________________________________________________
ERROR CODE W1004
JTXX out of motion range. Check operational area.
The robot motion exceeds the operational area set during auto load measurement.
⇒ Increase the range of motion set for auto load measurement.
⇒ Ensure the robot posture is configured as described in the auto load measurement
procedure.
_____________________________________________________________________
1-200
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W1005
Illegal center of gravity, default parameter is set.
Load mass value is set to a value other than zero, but the center of gravity is set to all
zeroes.
⇒ Enter the correct center of gravity value.
_____________________________________________________________________
ERROR CODE W1006
Incorrect load moment. Default parameter is set.
Load mass value and center of gravity are set, but the load moment of inertia is set to all
zeroes.
⇒ Set correct values for the load moment of inertia.
_____________________________________________________________________
ERROR CODE W1007
Application setting changed. Turn OFF & ON the control
power.
When application setting is changed, controller power must be cycled OFF and ON.
⇒ Cycle controller power OFF and ON.
_____________________________________________________________________
ERROR CODE W1008
Parameter changed. Turn OFF & ON the control power.
When parameters are changed, controller power must be cycled OFF and ON.
⇒ Cycle controller power OFF and ON.
_____________________________________________________________________
ERROR CODE W1009
Position envelope error of jtXX at last E-stop.
The error message is generated when an E-stop is applied and the position of the robot
is not within a range of the commanded position. The error deviation range is specified
in AUX 0503.
⇒ Before the error is reset, the operator must be aware of the robot’s position within the
work envelope.
_____________________________________________________________________
August 9, 2005
1-201
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W1010
RAM battery low voltage.
Main causes include:
1. Backup battery voltage below minimum value (3.3 VDC or less).
2. Defective battery harness.
3. Defective 1KA board.
⇒ Back up system and program data. Check and replace batteries as required.
⇒ Check batteries for defective connections. Repair as required.
⇒ Defective battery voltage monitoring circuit. Replace the 1KA board.
_____________________________________________________________________
ERROR CODE W1011
PLC alarm. (XX)
This error occurs when a PC3JB (TOYOPUC) internal error (alarm) is present (battery
voltage low error, etc.).
⇒ Refer to the PC3JB (TOYOPUC) manual for the alarm code (XX).
⇒ Replace the PC3JB (TOYOPUC).
_____________________________________________________________________
ERROR CODE W1012
Servo parameter Changed. Turn OFF & ON the control
power.
When robot model, number of axes, servo parameters for external axes, or the 1KB
board are changed, controller power must be cycled OFF and ON.
⇒ When model is changed, the servo software must also be changed.
⇒ Cycle controller power OFF and ON.
_____________________________________________________________________
1-202
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W1013
Encoder battery low voltage [Servo (XX)].
Voltage of the encoder back up battery on the 1FG/1HG board decreased to 3.3 volts or
less, or the encoder battery alarm signal (BAL_AL) is disconnected. This error is only
detected at control power on or motor power on.
Encoder Encoder
Servo
Encoder I/F
CPU
Battery alarm
error
Power circuit/
battery power
monitor circuit
1KB board
Battery
Encoder +12 VDC power supply
Controller
1FG/1HG board
Robot
Main causes include:
1. Discharged batteries.
2. Defective encoder battery board (1FG/1HG board).
3. Defective encoder.
4. Short in the harness from the encoder battery backup board to the encoder.
5. Short in the harness or defective encoder causing increased battery discharge.
6. Battery alarm signal line from the 1FG/1HG board is disconnected.
7. Defective servo board (1KB board).
⇒ Replace the battery. There is a possibility that internal encoder data may be lost.
Check the robot zeroing.
⇒ Check each harness for short circuit.
⇒ Replace the encoder, the 1KB servo board, or the 1FG/1HG encoder battery backup
board, if necessary.
_____________________________________________________________________
ERROR CODE W1014
Number of Axis Changed. Reinitialize.
The number of axis assigned to the robot has changed.
⇒ Change the number of axes and initialize the system.
_____________________________________________________________________
August 9, 2005
1-203
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W1015
Possibility of failure.
The monitored value of I2 (current squared) exceeds the normal value for the monitored
program and indicates excessive wear in the cyclo reduction unit or a servo motor/brake
problem.
Current increase may be caused by program modifications.
⇒ If the robot control program is modified, the monitored value of I2 may need to be re-
evaluated and changed.
⇒ Check and replace the worn cyclo reduction unit.
⇒ Check and replace the defective servo motor/brake assembly.
_____________________________________________________________________
ERROR CODE W1016
Torque of motor is over limit. JTXX
This error occurs when the current value exceeds the permitted set value. This error
may also occur if the overspeed load torque or inertia force is too high.
⇒ Ensure the robot program moves do not cause excessive load torque or inertia force.
⇒ Reduce the robot program speed or accel/decel parameters.
⇒ Ensure the load on the robot arm does not exceed the robot’s capacity.
_____________________________________________________________________
ERROR CODE W1017
Encoder battery low voltage. [External axis (XX)]
Main causes include:
1. Discharged batteries.
2. Defective encoder battery board (1FG/1HG board).
3. Defective encoder.
4. Short in the harness from the encoder battery backup board to the encoder.
5. Battery discharge.
6. Defective servo board (1KB board).
⇒ Exchange the battery. There is a possibility that internal encoder data may be lost.
Check the robot zeroing.
⇒ Check each harness for short circuit.
⇒ Replace the encoder, the 1KB servo board, or the 1FG/1HG encoder battery backup
board, if necessary.
_____________________________________________________________________
1-204
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W1018
Network parameter is changed. Turn OFF & ON the control
power.
When network setting data is changed, the controller power must be cycled OFF and
ON.
⇒ Cycle controller power OFF and ON.
_____________________________________________________________________
ERROR CODE W1019
The registered value is beyond rated load.
The moment of inertia of the tool exceeds the permitted value when the auto load mea-
surement is executed.
⇒ Ensure the tool and payload do not exceed the capacity of the robot.
⇒ Re-execute the auto load measurement.
_____________________________________________________________________
ERROR CODE W1020
Error sector was found.
This error occurs when a defective sector is detected on a floppy disk.
⇒ The disk may be used, but it is recommend to transfer the data to a new floppy disk.
_____________________________________________________________________
ERROR CODE W1021
The optimal posture can’t be found at present location.
When optimal configuration mode is selected, position and optimal tool posture, for
changing to linear motion, is not obtained in the current position and tool posture.
⇒ Select a different mode.
⇒ Change the robot position and tool posture and re-execute.
_____________________________________________________________________
ERROR CODE W4500
FIELD-BUS) Slave port OFFLINE.
Slave port is offline due to master power or communication line termination.
⇒ Check the master power and communication line and repair as necessary.
When repairs are completed wait for on-line status to return (1JF board LED 1 ON).
_____________________________________________________________________
August 9, 2005
1-205
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W4501
FIELD-BUS) Master port OFFLINE.
Master port is offline due to communication line termination.
⇒ Check the slave and communication line and repair as necessary.
When repairs are completed wait for on-line status to return (1JF board LED 1 ON).
_____________________________________________________________________
ERROR CODE W5001
PLC communication error.
During PLC communication through the remote I/O function, an error occurred.
Main causes include:
1. The PLC is not in run mode.
2. After the NAC (communication processor) is initialized the INIT_COMPLETE BIT is
not set ON.
⇒ Ensure the PLC is in run mode.
⇒ Ensure the NAC configuration is correct.
⇒ Ensure the PLC connection is established.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE W5002
Weld controller XX not connected.
During execution of the connection check sequence to the weld controller no response
is returned from the weld controller.
⇒ Ensure the welder connection is established. Repair or replace weld controller and
interface cable as necessary.
⇒ Ensure the welder is operational.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE W5003
Weld controller XX no response.
During communication with the weld controller, no response is returned.
⇒ Ensure the welder connection is established. Repair or replace weld controller and
interface cable as necessary.
⇒ Ensure the welder is operational.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
1-206
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W5004
Weld controller XX response error.
During communication with the weld controller, data received from the weld controller
does not conform to the specified protocol.
⇒ Ensure the welder connection is established. Repair or replace weld controller and
interface cable as necessary.
⇒ Ensure the welder is operational.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE W5005
(Spot welding) No response from RWC XX.
This error occurs when the robot controller sends weld conditions to the remote weld
controller (RWC), and does not receive a response (XX indicates the weld controller
number).
⇒ Defective welder or welder communication cables.
⇒ Defective 1KA/1GS board.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE W5006
(Spot welding) RWC response error XX.
This error occurs after weld conditions are sent to the specified remote weld controller
(RWC), and the response is abnormal (XX indicates the weld controller number).
⇒ Defective welder or welder communication cables.
⇒ Defective 1KA/1GS board.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
August 9, 2005
1-207
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W5007
(Spot welding) Weld fault XX.
This error occurs when a weld complete signal is not received by the robot controller
from the remote weld controller (RWC), or there is an electrical malfunction with the
RWC.
Code XX:
10: Under current
12: Short in SCR circuit
14: Data error
11: Over current
13: SCR did not fire
26: No weld
Typical electrical problems include:
Fluctuation in current, faulty SCR or SCR circuit, SCR has not fired, or abnormal line
voltage.
⇒ Defective welder or weld gun.
⇒ Defective 1KA/1GS board, or interface cables.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE W5008
(Spot welding) Cable disconnection error XX.
This error occurs when the robot controller detects a drop in current flow from the re-
mote weld controller (RWC) to the weld gun (XX indicates the weld controller number).
⇒ Defective welder or weld gun.
⇒ Defective 1KA/1GS board, or interface cables.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE W5009
(Spot welding) Internal leak XX.
Weld current data from the specified remote weld controller (RWC) is abnormal.
Short in secondary cable, or internal leak in secondary cable or weld gun.
⇒ Defective weld cable.
⇒ Defective weld controller or gun.
⇒ Defective 1KA/1GS board or interface cable.
⇒ Check for noise malfunction and shield integrity.
_____________________________________________________________________
1-208
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
ERROR CODE W5010
(Spot welding) Main cable exchange alarm XX.
The present value of the counter for the specified weld gun exceeds the set value for
initiating an alarm to replace the main cable (XX indicates gun number).
⇒ Reset the alarm counter value.
⇒ Replace the main cable.
⇒ Select a higher counter value.
_____________________________________________________________________
ERROR CODE W5011
(Spot welding) No connection with RWC XX.
The start-up sequence, for communication with the remote weld controller (RWC) during
power up, failed or cannot be executed.
⇒ Defective welder or welder interface cables.
⇒ Defective 1KA/1GS board.
_____________________________________________________________________
ERROR CODE W5012
Cannot achieve set force.
Set force is not achieved within five seconds of pressurization start for servo spot weld
gun.
Main causes include:
1. Excessive tip wear.
2. Wear measurement failure.
3. Incorrect program data in step where error occurs.
4. Clamping force value set too high.
5. Workpiece is too thin.
6. Incorrect lower limit setting (LLIMIT command).
⇒ Re-execute tip wear measurement.
⇒ Re-teach program step.
⇒ Set appropriate clamping force value.
⇒ Ensure workpiece is placed correctly
⇒ Ensure lower limit setting is correct (LLIMIT command).
_____________________________________________________________________
August 9, 2005
1-209
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
1.4 TROUBLESHOOTING FLOWCHARTS
The following flowcharts are arranged by error code number. Refer also to the corre-
sponding error code information in section 1.3.2.2 during troubleshooting procedures.
1-210
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1029
Does this
error occur just
after resetting error
E1035, E1036, or
E1037?
Follow
troubleshooting
flowchart for each
error
Yes
No
Replace encoder
Yes
Does
problem still
exist?
No
END
Yes
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Check connections at the
encoder connector
Check connections on the
1FG/1HG board
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
A
Figure 1-5 Error E1029 Flowchart (1)
August 9, 2005
1-211
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Does
problem still
exist?
No
END
Yes
Check inside
machine harness
and separation
harness
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-6 Error E1029 Flowchart (2)
1-212
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1032
Does this
error occur just
after resetting error
E1035, E1036, or
E1037?
Follow
troubleshooting
flowchart for each
error
Yes
No
No
END
Replace encoder
Yes
Does
problem still
exist?
Yes
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Check connections at the
encoder connector
Check connections on the
1FG/1HG board
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
A
Figure 1-7 Error E1032 Flowchart (1)
August 9, 2005
1-213
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Does
problem still
exist?
No
END
Yes
Check inside
machine harness
and separation
harness
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-8 Error E1032 Flowchart (2)
1-214
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1034
Does the
Reduce conveyor
encoder revolution
speed under 300
RPM at power-up
encoder revolve over
300 RPM?
(For conveyor encoder)
Yes
No
END
Check connections at the
encoder connector
Check connections on the
1FG/1HG board
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
Does
No
problem still
exist?
END
Yes
Replace encoder
Does
No
problem still
exist?
END
Yes
A
Figure 1-9 Error E1034 Flowchart (1)
August 9, 2005
1-215
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Check machine
harness and
separation harness
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-10 Error E1034 Flowchart (2)
1-216
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1035
Retry robot
program execution
or manual
Yes
Can you reset
the error?
operation carefully
No
Yes
Does the error
reoccur?
Check connections at the
encoder connector
No
Check connections on the
1FG/1HG board
END
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
Does
No
problem still
exist?
END
Yes
Replace encoder
Does
No
problem still
exist?
END
Yes
A
Figure 1-11 Error E1035 Flowchart (1)
August 9, 2005
1-217
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Check machine
harness and
separation harness
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-12 Error E1035 Flowchart (2)
1-218
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1036
Retry robot
program execution
or manual
Yes
Can you reset
the error?
operation carefully
No
Yes
Does the error
reoccur?
Check connections at the
encoder connector
No
Check connections on the
1FG/1HG board
END
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
Does
No
problem still
exist?
END
Yes
Replace encoder
Does
No
problem still
exist?
END
Yes
A
Figure 1-13 Error E1036 Flowchart (1)
August 9, 2005
1-219
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Check machine
harness and
separation harness
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-14 Error E1036 Flowchart (2)
1-220
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1037
Retry robot
program execution
or manual
Yes
Can you reset
the error?
operation carefully
No
Yes
Replace encoder
Yes
Does the error
reoccur?
No
Does
problem still
exist?
No
END
Yes
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Check connections at the
encoder connector
Check connections on the
1FG/1HG board
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
A
Figure 1-15 Error E1037 Flowchart (1)
August 9, 2005
1-221
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Does
problem still
exist?
No
END
Yes
Check inside
machine harness
and separation
harness
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-16 Error E1037 Flowchart (2)
1-222
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1038
Replace encoder
Does
problem still
exist?
No
END
Yes
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Check connections at the
encoder connector
Check connections on the
1FG/1HG board
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
Does
problem still
exist?
No
END
Yes
A
Figure 1-17 Error E1038 Flowchart (1)
August 9, 2005
1-223
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Check inside
machine harness
and separation
harness
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-18 Error E1038 Flowchart (2)
1-224
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
Error E1039
Replace encoder
Does
problem still
exist?
No
END
Yes
Replace 1KB board
Does
problem still
exist?
No
END
Yes
Check connections at the
encoder connector
Check connections on the
1FG/1HG board
Check connections in the
separation harness
Check connections, jumpers, and
switches on the 1KB board
Does
problem still
exist?
No
END
Yes
A
Figure 1-19 Error E1039 Flowchart (1)
August 9, 2005
1-225
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
TROUBLESHOOTING
A
Does
problem still
exist?
No
END
Yes
Check inside
machine harness
and separation
harness
Does
problem still
exist?
No
END
Yes
Replace 1FG/1HG board
Does
No
problem still
exist?
END
Yes
Service call
Figure 1-20 Error E1039 Flowchart (2)
1-226
August 9, 2005
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
s
TROUBLESHOOTING AND COMPONENT REPLACEMENT
2.0 COMPONENT REPLACEMENT
This chapter describes replacement procedure for parts inside the controller: printed boards,
power blocks, hardware including AVR, etc., and, units.
2.1
General Safety Precautions on Replacement······························································ 2
Replacement Procedure for Parts in Card Rack ························································· 4
1KA Board (User I/F Board)······················································································ 5
1KB Board (Arm Control Board) ·············································································· 6
1KP Board (Power Sequence Board)········································································· 7
AVR··························································································································· 7
1NR Board (Brake Control Board) ············································································ 9
Replacement Procedure for Power Block Unit ························································ 10
1KC Power Block Unit···························································································· 10
1KD Power Block Unit (for D3x Controller)··························································· 11
1KD Power Block Unit (for D7x Controller)··························································· 12
1KL Power Block Unit ···························································································· 14
1KR Power Block Unit···························································································· 14
Replacement Procedure for MC Unit Parts (for D3x Controller)····························· 15
MC Unit··················································································································· 15
1KQ Board (Power Circuit Board) ·········································································· 16
Replacement Procedure for 1NQ Board (for D7x Controller)·································· 18
Replacement Procedure for Fan (for D3x Controller)·············································· 19
Fan for Card Rack···································································································· 19
Fans on the Back of Controller ················································································ 20
2.2
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
2.3
2.3.1
2.3.2
2.3.3
2.3.4
2.3.5
2.4
2.4.1
2.4.2
2.5
2.6
2.6.1
2.6.2
2.6.2.1 Upper Fan on Back of Controller············································································· 20
2.6.2.2 Lower Fan on Back of Controller ············································································ 21
2.6.3
2.7
MC Unit Fan············································································································ 22
Replacement Procedure for Fan (for D7x Controller)·············································· 23
Fan for Card Rack···································································································· 23
Fan for Power Block Unit························································································ 24
Heat Exchange Fan (for D71/74/77 Controller)······················································· 25
Replacement Procedure for Batteries······································································· 26
Battery on 1KA Board ····························································································· 26
Battery on 1FG/1HG Board····················································································· 27
Replacement Procedure for Fuses············································································ 28
Fuses on 1KP Board ································································································ 28
Fuses on 1NQ Board (for D7x Controller)······························································· 29
Replacement Procedure for Filter ············································································ 30
2.7.1
2.7.2
2.7.3
2.8
2.8.1
2.8.2
2.9
2.9.1
2.9.2
2.10
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.1
GENERAL SAFETY PRECAUTIONS ON REPLACEMENT
This section describes the precautions to be taken when replacing parts due to trouble, etc.
This information is presented here for use as general precautions. In addition to these,
adhere the safety measures required for each replacement procedure.
CAUTION
!
Parts replacement duties are limited to personnel who have
completed special training and education for the installed
robot or for an equivalent model.
1. Read and understand thoroughly all manuals, specifications and related documents
provided by Kawasaki before operation.
2. Before entering the safety fence (safeguarded space), make sure all necessary safety
measures are prepared and functioning well.
3. Before starting replacement work, shut OFF control power up to the main power source.
Display signs indicating clearly “POWER CUT-OFF IN PROGRESS” or
“REPLACEMENT IN PROGRESS”, and lock out/tag out the main power switch to
prevent personnel from accidentally turning ON the power.
4. Before starting replacement work, secure enough space around the robot so there is no
danger of interference with peripheral systems. Set the peripheral systems in a fixed
status so they will not make any sudden motion.
5. Disable automatic operation functions when entering the safety fence. If the robot
makes any abnormal motion, press EMERGENCY STOP switch immediately, and
evacuate on a planned path of retreat.
6. In addition to the EMERGENCY STOP switch held by the technician, install another
E-STOP switch for the supervisor outside the safety fence, in a place where the robot’s
entire motion range can be monitored. If the robot moves abnormally during
observation of the replacement, the E-STOP switch should be accessible and easy for the
supervisor to press. After an E-Stop, reset and restart robot operations from outside the
fence. Moreover, monitoring duties are limited to personnel who are trained and
qualified.
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
7. Use only Kawasaki approved parts during replacement.
8. When replacing printed boards, do not fail to turn OFF control power. To replace
power block, MC unit, or AVR, wait at least seven minutes after control power OFF
before removing connectors. Then confirm that output voltage from the DC power
source and the P-N voltage are 0V.
9. During operation, both technician and supervisor must always watch out for abnormal
motion and possible pinch points in and around the robot.
10. Semiconductors are often used in printed boards. Note that these semiconductors are
sensitive to static electricity, be sure to discharge any electrostatic on the body before
handling the printed boards.
11. Directly touching the parts containing semiconductors may cause electrostatic discharge
damage. When handling printed boards, do not touch the semiconductors directly but
hold the periphery of the printed boards. If parts must be touched directly, confirm that
electrostatic on the body has been discharged.
12. Putting printed boards directly onto the controller, etc. may cause electrostatic discharge
damage. Be sure to put them on an electrostatic-proof mat board or sheet, or enclose
printed boards in an electrostatic-proof bag.
13. Avoid removing printed boards at control power ON, or turning the control power ON
without any printed boards mounted.
14. Take a record of all data settings currently on controller, printed boards, etc. so the
system can be restored to its normal operating condition.
15. To prevent displacement of the robot, take a record of the robot’s pose before starting the
replacement procedure.
16. Be sure to connect connectors and cables correctly. When using connectors equipped
with locks, do not fail to lock after insertion. Do not touch connector pins.
17. Immediately after robot movement, the heat sink, the regenerative resistor, etc. may be
very hot. Do not touch the power block unit directly, there is a danger of burn.
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
18. Printed boards and power blocks are designed differently for each robot model. Be sure
to replace the correct type.
19. When air or water is supplied, shut OFF the supply source and purge any remaining
pressure from the lines before starting any replacement procedure.
20. Use lighting of 1500 lux or more to avoid mistakes when reading data or replacing
defective parts.
21. After completion of replacement, confirm that the controller functions with no
abnormality.
2.2
REPLACEMENT PROCEDURE FOR PARTS IN CARD RACK
In the card rack of D3x controller, the 1KP board (power sequence board), 1KB board (arm
control board), 1KA board (user I/F board), optional board, and the AVR are housed from the
left as shown below. For D7x controller, the 1NR board (brake control board) is housed in
the leftmost of the card rack.
This section describes the replacement procedure for the parts inside the card rack.
AVR
Optional board
1KA board
1KB board
1KP board
2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
s
TROUBLESHOOTING AND COMPONENT REPLACEMENT
2.2.1 1KA BOARD (USER I/F BOARD)
1. This is the user I/F board used for storing taught pose data, user program data, etc. in
memory. Before replacing the board, be sure to save all data to storage media such as
PCCARD, FDD, etc. For more details about data saving procedures, refer to the
Operation Manual, a separate volume.
2. After completion of data saving, turn OFF the control power.
3. Press the red button on the ejector of the 1KA board to release the lock, and pull out the
1KA from the card rack by extending the ejector up and down.
4. When replacing only the 1KA, disassemble daughter boards, 1KK, 1KN/1QN and
1KJ/1QJ, by removing their connecting screws to the 1KA and then the daughter boards.
5. Confirm that settings for SW1 and SW2 on the new 1KA are the same as before board
replacement. For the daughter boards disassembled in step 4, reassemble them to the
new 1KA.
6. Insert the new 1KA to the card rack and set it in the mother board.
7. Turn ON the SW2-8 on the 1KA.
8. Turn ON the control power. When the initialization prompt is displayed on the teach
pendant display, select “999: Initialization of all data”.
9. When the confirmation query for initialization is displayed, select “1: YES”.
10. After completion of initialization, load all data saved before board replacement to the
1KA. For more details about data loading procedure, refer to the Operation Manual, a
separate volume.
11. Turn OFF the SW2-8 on the 1KA.
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
s
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Buttons of the ejector
CN8
SW2
SW1
CN11
Battery
CN6
connector
CN7
1KN/1QN board
CN9
CN2
CN3
IP board
1KJ/1QJ
board
CN5
1KK board
CN4
CN10
Overview of the 1KA board
2.2.2 1KB BOARD (ARM CONTROL BOARD)
1. Turn OFF the control power.
2. Press the red button on the ejector of the 1KB board to release the lock, and pull out the
1KB from the card rack by extending the ejector up and down.
3. Confirm that settings for SW1 to SW8 and SW10 on the new 1KB are the same as before
board replacement. Then, insert the new 1KB to the card rack and set it in the mother
board.
Button of the ejector
Button of the ejector
SW
SW
Overview of the 1KB board
2-6
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.2.3 1KP BOARD (POWER SEQUENCE BOARD)
1. Turn OFF the control power.
2. Loosen the screws on top and bottom of the 1KP board, and pull out the 1KP from the card
rack by holding the ejectors at both ends of the board. If wired to the front connector,
remove the connector first.
3. Confirm that settings for SW, J1 and J2 on the new 1KP are the same as before board
replacement. Then, insert the new 1KP to the card rack and set it in the mother board.
4. Fasten the screws on top and bottom of the 1KP.
Ejector
Ejector
Screw
Screw
J1, J2
SW
Overview of the 1KP board
2.2.4 AVR
1. Turn OFF the control power.
2. Remove the connectors connected to the AVR.
3. Loosen the two screws fixing the AVR, and remove the AVR.
4. Insert the new AVR to the card rack, and fasten it with the two screws.
5. Restore the connectors removed in step 2 and turn ON the control power.
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
6. Confirm the voltage at each check pin on the 1KA and 1KP as shown below.
1KA board
No. Color Standard
Allowable range
If the voltage is out of allowable range,
Adjust the volume on the AVR.
Adjust the volume on the AVR.
Adjust the volume on the AVR.
Replace the 1KA.
TP2 Yellow
−12.0 V −11.95 V∼ −12.05 V
TP3 Yellow +12.0 V
TP4 Yellow +5.0 V
TP6 Yellow +3.3 V
+11.95 V∼ +12.05 V
+4.95 V∼ +5.05 V
+3.16 V∼ +3.44 V
1KP board
No. Color Standard
TP1 White +24.0 V
Allowable range
If the voltage is out of allowable range,
Replace the AVR.
+23.9 V∼ +24.7 V
7. If there is no abnormality in the controller after checking voltage, paint lock each adjust
volume of the AVR.
Screw
Connector
+5V Adjust
Volume
+12V Adjust
Screw
−12V Adjust
Volume
(enlarged view)
Overview of the AVR
2-8
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.2.5 1NR BOARD (BRAKE CONTROL BOARD)
1. Turn OFF the control power.
2. Loosen the screws on top and bottom of the 1NR board, and pull out the 1NR from the
card rack by holding the ejectors at both ends of the board. If wired to the front connector,
remove the connector first.
3. Confirm that settings for J1, J2 and J3 on the new 1NR are the same as before board
replacement. Then, insert the new 1NR to the card rack and set it in the mother board.
4. Fasten the screws on top and bottom of the 1NR.
Ejector
Screw
Ejector
Screw
J3
J2 J1
Overview of the 1NR board
2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.3
REPLACEMENT PROCEDURE FOR POWER BLOCK UNIT
This section describes the replacement procedure for the power block unit mounted in the
controller.
Four types of power block are available as described below.
1. 1KC: Power block for large robot (six axes)
2. 1KD: Power block for small robot (six axes)
3. 1KL: Optional power block for large motor (single axis)
4. 1KR: Optional power block for small motor (single axis)
Replacement procedures for the 1KC and 1KD are described in this section.
DANGER
!
High voltage is applied in the power block unit. Do
not touch any connector pin during replacement.
2.3.1 1KC POWER BLOCK UNIT
DANGER
!
Before starting replacement work, turn OFF the control
power and wait at least seven minutes.
WARNING
!
Do not remove the screws or cover from the front of the
power block unit. This is a high voltage area and there is
a danger of electric shock.
CAUTION
!
Power block unit weighs approx. 20kg. Be careful not to
incur back injury, etc. when removing the power block unit.
2-10
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
1. Remove all connectors connected to the power block unit.
2. Loosen the four screws fixing the power block unit to the controller so that the power
block unit can be removed from the controller. (These screws are not removed from the
power block unit.)
3. To remove the power block unit, pull it out by sliding on the fulcrum. To be safe, hold the
handle on top with one hand.
4. Place the new unit on the fulcrum, and set it in by holding the handle on top with one hand.
Then, attach it to the controller by fastening the four screws correctly.
5. Restore the connectors removed in step 1.
Fixing screws (two in upper corners)
Fixing screws (two in lower corners)
Details for screws
: Screws on the front of power block unit
(Do not touch any of these screws.)
2.3.2 1KD POWER BLOCK UNIT (FOR D3X CONTROLLER)
The replacement procedure for the 1KD is same as that for the 1KC. However, the external
view of the power block unit is different between the 1KC and the 1KD.
2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.3.3 1KD POWER BLOCK UNIT (FOR D7X CONTROLLER)
DANGER
!
Before starting replacement work, turn OFF the control
power and wait at least seven minutes.
1. Remove the controller cover.
2. Remove the connectors X506 and X507 connected to the power block unit.
3. Remove the screw fixing the earth wired from the power block unit.
4. Remove the four screws fixing the power block unit to the controller.
5. Pull out the power block unit by sliding backward on the fulcrum.
6. Remove the connectors X302 and X311.
7. Remove the connectors X211 and X212.
8. Remove the power block unit.
9. Attach the new unit to the controller in reverse order of removal.
Power block unit (1KD)
X212
X211
X506
X507
Earth
2-12
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
s
TROUBLESHOOTING AND COMPONENT REPLACEMENT
X302
X311
Fixing screws (two in upper corners)
Fixing screws (two in lower corners)
2-13
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
s
TROUBLESHOOTING AND COMPONENT REPLACEMENT
2.3.4 1KL POWER BLOCK UNIT
DANGER
!
Before starting replacement work, turn OFF the
control power and wait at least seven minutes.
1. Remove all connectors connected to the power block unit.
2. Loosen the four screws fixing the power block unit to the controller (1 to 4 in figure
below) so that the power block unit can be removed from the controller. (These screws
are not removed from the power block unit.)
3. Remove the power block unit.
4. Attach the new unit to the controller by fastening the four screws removed in step 2
correctly.
5. Restore the connectors removed in step 1.
1
2
4
3
2.3.5 1KR POWER BLOCK UNIT
The replacement procedure for the 1KR is same as that for the 1KL.
2-14
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.4
REPLACEMENT PROCEDURE FOR MC UNIT PARTS (FOR D3X
CONTROLLER)
This section describes the replacement procedure for the MC unit (power supply unit) and the
1KQ board (power circuit board) which flanks the MC unit.
2.4.1 MC UNIT
DANGER
!
Before starting replacement work, turn OFF the
control power and wait at least seven minutes.
1. To facilitate the replacement process, remove all connectors and power block connectors
connected to the MC unit.
2. Loosen the four screws fixing the MC unit to the controller, then remove the MC unit from
the controller.* (See figure below.)
NOTE* Fully removing the screws may cause the MC unit to drop, or make the restoration
process unnecessarily difficult. Be sure to leave the screws on the controller side.
3. Attach the new MC unit to the controller, and fasten it with the four screws.**
NOTE** Be careful not to let the washers/screws fall under the MC unit.
4. Restore the connectors removed in step 1.
Fixing screws
(two in upper corners)
MC unit
Fixing screws
(two in lower corners)
2-15
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
CAUTION
!
MC unit weighs approx. 6kg. Be careful not to cut or
squeeze the tips of your fingers when replacing MC unit.
2.4.2 1KQ BOARD (POWER CIRCUIT BOARD)
DANGER
!
Before starting replacement work, turn OFF the
control power and wait at least seven minutes.
1. Remove the MC unit. For details, refer to 2.4.1 MC Unit.
2. Remove the four screws fixing the 1KQ board assy to the MC unit (1 to 4 in figure below),
the one screw fixing the fan unit of the MC unit (5 in figure below), and the connector for
the fan. Then, pull out the 1KQ board assy.
1
2
3
1KQ board
4
MC unit
Connector
5
3. Remove the connector and the two wires of the 1KQ, then remove the 1KQ board assy
from the MC unit.
2-16
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
4. Loosen the five nuts fixing the 1KQ to the plate (1 to 5 in figure below), and remove the
1KQ.
5. Attach the new 1KQ to the plate with the five nuts removed in step 4.
6. Restore the connector and two wires removed in step 3 to the assy assembled in step 5.
7. Refasten the screws and connect the connector removed in step 2.
8. Attach the MC unit to the controller. For details, refer to 2.4.1 MC Unit.
Connector to be
Plate
1KQ board
1
removed in step 3
2
3
4
5
Wires to be removed
in step 3
2-17
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.5
REPLACEMENT PROCEDURE FOR 1NQ BOARD (FOR D7X
CONTROLLER)
This section describes the replacement procedure for the 1NQ board (power circuit board)
1. Turn OFF the control power.
2. Remove the power block unit. (For the procedure, see 2.3.3 1KD Power Block Unit (for
D7x Controller).)
3. Remove the 1NR, 1KP, 1KB, and 1KA boards in the card rack.
4. Remove all connectors connected to the 1NQ board.
5. Remove the five screws fixing the 1NQ board.
6. Remove the 1NQ board from back side.
7. Attach the new 1NQ board by fastening the five screws.
8. Restore the connectors removed in step 4.
9. Restore the boards removed in step 3.
10. Restore the power block unit to the controller.
1NQ board
Screws for fixing
the 1NQ board
2-18
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.6
REPLACEMENT PROCEDURE FOR FAN (FOR D3X CONTROLLER)
Fans are installed for the card rack, the power block unit, and the MC unit. This section
describes the replacement procedure for these fans.
2.6.1 FAN FOR CARD RACK
1. Turn OFF the control power.
2. Remove the connector connecting the fan to the card rack. Then, loosen and remove the
two screws fixing the fan unit.
3. Remove the power line and the earth wire connected to the fan. Loosen the four screws
fixing the fan, and then remove the fan.
4. Attach the new fan with the four screws, and restore the power line and earth wire removed
in step 3. Be sure to reattach the fan correctly; wind blows top to down.
5. Attach the fan unit to the top of the card rack, and fasten it with the two screws.
6. Restore the connector removed in step 2.
Screws for
fixing the fan
Connector
2-19
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.6.2 FANS ON THE BACK OF CONTROLLER
This section describes the replacement procedures for the two fans mounted on the controller
back. The upper fan cannot be seen from outside.
2.6.2.1 UPPER FAN ON BACK OF CONTROLLER
1. Turn OFF the control power.
2. Remove the six screws fixing the plate on the controller back (1 to 6 in figure below).
3. Pull out the plate, remove the connector connected to the controller, then remove the plate.
4. Remove the power line and the earth wire connected to the fan. Loosen and remove the
four screws fixing the fan, and then remove the fan.
5. Attach the new fan to the plate with the four screws, and restore the power line and earth
wire removed in step 4. Be sure to reattach the fan correctly; wind blows top to down.
6. Restore the connector removed in step 3, and reattach the plate with the six screws.
Fan (upper)
1
4
5
2
3
6
2-20
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.6.2.2 LOWER FAN ON BACK OF CONTROLLER
1. Turn OFF the control power.
2. Remove the six screws fixing the plate on the controller back.
3. Pull out the plate, remove the connector connected to the controller, and remove the plate.
4. Remove the power line and the earth wire connected to the fan. Loosen and remove the
four screws fixing the fan, and then remove the fan.
5. Attach the new fan to the plate with the four screws, and restore the power line and earth
wire removed in step 4. Be sure to reattach the fan correctly; wind blows from inside to
outside.
6. Restore the connector removed in step 3, and reattach the plate to the controller with the
six screws.
1
2
4
5
Fan (lower)
6
2-21
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.6.3 MC UNIT FAN
1. Turn OFF the control power.
2. Remove the two screws at the bottom of the MC unit (1 and 2 in figure below) and pull out
the plate. Remove the connecter connected to the 1KQ board and remove the fan unit.
3. Remove the four screws fixing the fan and remove the fan.
4. Attach the new fan to the plate with the four screws. Be sure to reattach the fan correctly;
wind blows top to down.
5. Restore the connector removed in step 2, and attach the plate to the MC unit with the two
screws.
MC unit
1KQ board
Connector
1
2
Four screws for
fixing the fan
2-22
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.7
REPLACEMENT PROCEDURE FOR FAN (FOR D7X CONTROLLER)
Fans are installed for the card rack, the power block unit, and the cover (only for D71/74/77
controller). This section describes the replacement procedure for these fans.
2.7.1 FAN FOR CARD RACK
1. Turn OFF the control power.
2. Open the controller cover.
3. Remove the four screws fixing the fan.
4. Remove the power line and the earth wire connected to the fan, and then remove the fan.
5. Restore the power line and earth wire removed in step 4 to the new fan.
6. Fix the fan with the four screws. Be sure to reattach the fan correctly; wind blows top to
down.
Screws for fixing the fan
Screws for fixing the fan
2-23
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
s
TROUBLESHOOTING AND COMPONENT REPLACEMENT
2.7.2 FAN FOR POWER BLOCK UNIT
1. Turn OFF the control power.
2. Remove the four screws fixing the cover on the controller back, and then remove the cover.
3. Remove the four screws fixing the fan.
4. Remove the power line and the earth wire connected to the fan, and then remove the fan.
5. Restore the power line and earth wire removed in step 4 to the new fan.
6. Fix the fan with the four screws. Be sure to reattach the fan correctly; wind blows from
outside to inside.
7. Restore the cover on the controller back with the four screw.
Fixing screws (two in upper corners)
Cover on the
controller back
Screws for
fixing the fan
Fixing screws (two in lower corners)
2-24
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.7.3 HEAT EXCHANGE FAN (FOR D71/74/77 CONTROLLER)
Heat exchange fan is installed on the left side of the controller cover.
1. Turn OFF the control power.
2. Remove the controller cover.
3. Remove the power harness from the bands which fix the harness.
4. Remove the four screws fixing the fan, and then remove the fan.
5. Attach the new fan with the four screws. Be sure to reattach the fan correctly.
6. Restore the power harness removed in step 3 with the bands.
7. Restore the controller cover.
Band
Power harness
Heat exchange fan
2-25
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.8
REPLACEMENT PROCEDURE FOR BATTERIES
This section describes the replacement procedure for the battery provided to backup data.
2.8.1 BATTERY ON 1KA BOARD
As backup power supply for SRAM and RTC (Real Time Clock), the 1KA board is equipped
with a lithium battery and an emergency super capacitor for use during battery replacement.
When on-board battery is removed, fully charged super capacitor can provide backup power
for only 15 minutes. Therefore, battery should be replaced immediately once the control
power is cut OFF.
CAUTION
!
To prevent data erasion, be sure to save program data
as soon as it is completed.
1. Before replacing the battery, confirm that the new battery has +3.6V or more voltage.
2. Turn OFF the control power.
3. Remove the battery connector of the 1KA and pull out the battery from the holder. When
it is hard to work on, pull out the 1KA. For more details about pulling out the board,
refer to 2.2.1 1KA Board (User I/F Board).
4. After installing the new battery to the holder, connect the battery connector. If the 1KA
was pulled out, put it back to the original place.
CN8
SW2
SW1
CN11
Battery
CN6
connector
CN7
1KN/1QN board
CN9
CN2
CN3
IP board
1KJ/1QJ
board
CN5
1KK board
CN4
CN10
2-26
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
s
TROUBLESHOOTING AND COMPONENT REPLACEMENT
2.8.2 BATTERY ON 1FG/1HG BOARD
1. Record the encoder value for all axes before replacing a battery.
2. Before replacing the battery, confirm that the new battery has +3.6V or more voltage.
3. Turn OFF the control power.
4. For the 1HG board, pull out the connector box located on the base of the robot main body.
For the 1FG board, remove the plate that is installed with a battery.
5. Remove the battery connector (CN10 for 1FG, CN4 for 1HG), cut two bands fixing the
battery, and remove the battery.
6. Fix the new battery with two bands, and restore the connector removed in step 4.
7. For the 1HG, restore the connector box. For the 1FG, restore the plate that is installed
with a battery.
8. Reinstall the cover on the robot arm. Turn ON the control power and check if the encoder
value has changed.
CAUTION
!
1. Battery life is about year and a half (assuming control power is OFF
continuously), but longevity differs depending on ambient temperature, etc.
2. The encoder assembly contains a super capacitor that maintains memory
power for approximately 30 minutes. In order to maintain encoder data
when replacing the 1FG batteries or disconnecting the encoder from the
1FG board, the batteries must be replaced or the encoder reconnected
within the 30 minutes period. (Take note that if the super capacitor is not
fully charged, encoder data may not be maintained for the full 30 minutes.)
2-27
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.9
REPLACEMENT PROCEDURE FOR FUSES
This section describes the replacement procedure for the fuses.
2.9.1 FUSES ON 1KP BOARD
Two types of fuses- Fuse1 and Fuse2- are mounted on the 1KP board.
1. Turn OFF the control power.
2. Push the fuse on the front of the board and turn it 90 degrees to the left. Then pull it out
and remove the fuse from the board.
3. Push in the new fuse, and turn it 90 degrees to the right to install.
Fuse1 (E-Stop: 315 mA)
Fuse2 (Machine valves: 1A)
Overview of the 1KP board
2-28
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.9.2 FUSES ON 1NQ BOARD (FOR D7X CONTROLLER)
1. Turn OFF the control power.
2. Remove the controller cover.
3. Turn the fuse 90 degrees to the left. Then pull it out and remove the fuse from the board.
4. Push in the new fuse, and turn it 90 degrees to the right to install.
5. Restore the controller cover.
1NQ board
F1 (1A)
F2 (1A)
2-29
Download from Www.Somanuals.com. All Manuals Search And Download.
D SERIES CONTROLLER
Kawa ak
TROUBLESHOOTING AND COMPONENT REPLACEMENT
s
2.10
REPLACEMENT PROCEDURE FOR FILTER
Wash filters periodically to keep them clean. For replacement, follow the replacement
procedure described below.
Filters are located on the side and back of the controller. Take the same procedure to replace
these filters.
1. In the center, bottom of the holder for the filter there is a notch. Insert something tube
shaped into the notch, and push up the filter. Be careful not to damage the controller face.
2. Pull up the raised filter.
3. Insert the replacement filter into the holder.
Filter (on back)
Notch
Filter (on side)
Notch
Side and back of the controller
2-30
Download from Www.Somanuals.com. All Manuals Search And Download.
|