		 JLBIHD908   
					Built-in cooker hood   
					Instruction manual   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Contents   
					For the User   
					For the Installer   
					Important Safety Information   
					Description of the Appliance   
					2 
					Electrical Connections   
					Electrical Requirements   
					Electrical Connection   
					8 
					8 
					8 
					4 
					Using the cooker hood   
					Cooker Hood Controls   
					To Operate   
					9 
					9 
					Installing the Cooker Hood   
					Installation Requirements   
					Unpacking   
					5 
					5 
					5 
					6 
					6 
					7 
					7 
					10   
					10   
					10   
					Recirculation   
					Extraction   
					Fitting theWall Brackets   
					Fitting the Canopy Hood   
					Extraction   
					Maintenance and Cleaning   
					External Cleaning   
					11   
					11   
					11   
					11   
					12   
					12   
					13   
					Recirculation   
					Cleaning the Ducting panels   
					Metal Grease Filters   
					Charcoal Filters   
					To Remove/Replace Charcoal Filter   
					Changing the Halogen Spot Lamp   
					Something NotWorking   
					14   
					14   
					Repairs and After Sales Service   
					Guide to use the Instruction Manual   
					The following symbols will be found in the text to guide   
					you through the instruction book   
					Safety instructions   
					Step by step instructions   
					Environmental Information   
					This appliance complies with the fol-   
					lowings E.E.C. Directives:   
					- 89/336 (Electromagnetic Compat-   
					ibility Directive)   
					- 73/23 (LowVoltage Directive)   
					- 93/68 (General Directives)   
					and subsequent modifications   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Description of the appliance   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Installation   
					Please ensure that when the appliance is installed   
					it is easily accessible to an engineer in the event   
					of a breakdown.   
					All installations must comply with the local   
					authorities requirements for the discharge of   
					exhaust air.   
					Incorrect installation may affect the safety of   
					this cooker hood.   
					Installation Requirements   
					Before installation check the wall to which   
					the cooker hood is to be fitted for electric   
					cables, water pipes or gas.   
					The chimney hood must be installed accord-   
					ing to the instructions suppliers below and   
					by qualified and competent personnel to the   
					relevant National Standards.   
					This cooker hood is designed to be fixed to any vertical   
					surface over a cooking area,and can be used in the extrac-   
					tion (ducted to the outside) or recirculation mode.   
					The installation work must be undertaken by a qualified   
					and competent person.   
					The manufacturer disclaims any responsibility for dam-   
					age due to incorrect installation of the cooker hood or   
					if the hood is not installed in compliance with relevant   
					regulations controlling this type of installation.   
					Unpacking   
					Before unpacking the cooker hood position the carton   
					with the arrows pointing upwards as illustrated on the   
					carton.   
					���   
					� 
					���   
					The cooker hood is made up of the following compo-   
					nents:   
					��   
					Ref Qty Product Components   
					���   
					1 
					1 
					Canopy complete with: Controls, Light-   
					ing, Fan Assembly, Grease Filter, Charcoal   
					Filter.   
					8 
					1 
					1 
					Recirculation grille   
					Filter Cover   
					� 
					16   
					Ref Qty Installation Components   
					��   
					���   
					11   
					2 
					2 
					2 
					4 
					2 
					SecurityWall plugs   
					11a   
					12a   
					12c   
					12d   
					Wall plugs SB 12/10   
					Security screws   
					Filter cover fixing screws   
					Recirculation grille fixing screws   
					Ref Qty Documentation   
					Instruction booklet   
					1 
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Installing the cooker hood   
					Fitting the wall brackets   
					Draw a vertical line on the supporting wall up to the   
					ceiling, or as high as practical, at the centre of the area   
					in which the hood will be installed.   
					• 
					• 
					• 
					Draw a horizontal line at 850 mm above the hob.   
					Mark a point (1) on the horizontal line, 250 mm to the   
					right of the vertical reference line.   
					��� ���   
					��� ���   
					• 
					• 
					• 
					• 
					Repeat this operation on the other side, checking that   
					the two marks are level.   
					� 
					� 
					���   
					���   
					Mark a reference point (2) as indicated at 200 mm from   
					the vertical reference line and 540 mm above the hob.   
					Repeat this operation on the other side, checking that   
					the two marks are level.   
					��   
					� 
					� 
					Drill at the points (1) marked, using a ø 12 mm drill   
					bit.   
					• 
					• 
					Drill at the points (2) marked, using a ø 8 mm drill bit.   
					Insert the bracket plugs 11a into the holes 1 and screw   
					into place.   
					• 
					Insert the wall plugs 11 in the holes. 2.   
					Note: If the hood is to be installed onto a hollow   
					construction or plaster or partition board wall   
					then special fixing screws will be required (not   
					supplied).   
					���   
					Fitting the canopy hood   
					Disconnect by pulling only the central ducting panels.   
					Remove the metal grease filters (see Maintenance para-   
					graph)   
					• 
					• 
					��   
					• 
					Adjust the two screws Vr, on brackets 11a, to a mini-   
					mum.   
					• 
					• 
					Hook the hood canopy onto the two brackets 11a.   
					From inside the hood canopy, adjust the screws Vr to   
					set the Hood Canopy level.   
					• 
					Tighten the safety screw 12a.   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Extraction (Ducted)   
					The cooker hood is more effective when installed in the   
					extraction mode (ducted to the outside).   
					Venting kits may be purchased through your retailer or   
					DIY store, and must be evacuated through an outside   
					vent of ø125 (5ins) or ø150mm (6ins).   
					The ducting used must be manufactured from fire retard-   
					ant material conforming to the relevant British Standard   
					or DIN 4102-B1.   
					When the cooker hood is ducted to the outside   
					the charcoal filter must be removed.   
					Fitting the Ducting   
					To install the Ducting Version of the hood, the optional   
					• 
					Ducting chimney kit must be purchased.   
					Recirculation Mode   
					The cooker hood is supplied specified for use in the recircula-   
					���   
					� 
					���   
					tion mode, with the charcoal filter fitted.   
					In the recirculation mode contaminated air is passed through   
					the charcoal filter to be purified and recirculated into the kitch-   
					en through the grille outlets on either side of the chimney.   
					��   
					• 
					Screw the filter cover item 16 onto the air outlet, using   
					four screws 12c (2.9 x 12.5) supplied.   
					• 
					• 
					Fix the directional grille item 8 on the recirculation air   
					outlet using the 2 screws 12d (2,9 x 9,5) supplied.   
					Ensure the activated charcoal filter has been fitted.   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Electrical connection   
					THIS APPLIANCE MUST BE EARTHED   
					Electrical requirements   
					Any permanent electrical installation must comply with   
					the latest I.E.E. Regulations and local Electricity Board   
					regulations. For your own safety this should be under-   
					taken by a qualified electrician e.g. your local Electricity   
					Board,or a contractor who is on the roll of the National   
					Inspection Council for Electrical Installation Contracting   
					(NICEIC).   
					Electrical connection   
					Before connecting to the mains supply ensure that the   
					mains voltage corresponds to the voltage on the rating   
					plate inside the cooker hood.   
					Remove the grease filters (see paragraph Maintenance)   
					making sure that the connector of the feeding cable is   
					correctly inserted in the socket placed on the side of   
					the fan.   
					This appliance is fitted with a 3 core mains cable and   
					must be permanently connected to the electricity supply   
					via a double-pole switch having 3mm minimum contact   
					gap on each pole.A Switched Fuse Connection Unit to   
					BS1363 Part 4, fitted with a 3 Amp fuse, is a recom-   
					mended mains supply connection accessory to ensure   
					compliance with the Safety Requirements applicable to   
					fixed wiring instructions.   
					This appliance conforms to BS 800: 1988 and EEC Di-   
					rective No. 78 308 regarding suppression of radio and   
					television interference.   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Using the cooker hood   
					The cooker hood is designed to extract unpleasant odours from the kitchen, it   
					will not extract steam.The appliance can be installed to recirculate or extract   
					contaminated air.   
					Cooker hood controls   
					The hood can be switched on pushing directly onto the requested speed   
					without firstly having to select 0/1 button.   
					KEY   
					LED   
					FUNCTIoNS   
					� 
					L 
					0/1 Light   
					Turns lighting on and off.   
					T1 0/1 Motor on   
					First speed.   
					When pressed for about 1 second the motor is   
					switched off.   
					��   
					��   
					��   
					��   
					Flashing 24h Changeover   
					This is enabled by pressing and holding the button   
					for approximately 5 seconds. It allows a suction   
					level of 100 m3/h with a noise level of just 28dB(A).   
					Can be enabled at any speed, even with the hood   
					turned off. To disable, press and hold the button for   
					approximately 5 seconds.   
					T2 Speed   
					on   
					Second speed.   
					Flashing Delay (30 minutes)   
					Press the button for approximately 2 seconds to   
					enable automatic shutdown with a 30 minutes delay.   
					Suitable to complete elimination of any residual   
					smells. Can be enabled at any speed and is disabled   
					by pressing the button briefly.   
					��   
					T3 Speed   
					T4 Speed   
					on   
					Third speed.   
					Max. speed   
					Fixed   
					Flashing Intensive speed.   
					Suitable for the strongest cooking vapours and   
					odours. The function becomes active when the   
					button is pushed for about 2 seconds. After 10   
					minutes of functioning it turns off automatically.   
					This function can be interrupted by means of   
					pressing any of the buttons.   
					S1 Led   
					Fixed   
					Indicates that the Metal grease filters saturation   
					alarm has been triggered, and the filters need to be   
					washed. The alarm is triggered after 100 working   
					hours. (Reset; check the Maintenance-paragraph)   
					Flashing Indicates that the activated charcoal odour filter   
					saturation alarm has been triggered, and the filter   
					has to be replaced;the metal grease filters must also   
					be washed. The activated charcoal odour filter is   
					triggered after 200 working hours. (Activation and   
					Reset; check the Maintenance-paragraph)   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				To operate   
					Select the required fan speed and light if required.   
					Recirculation   
					In the recirculation mode the contaminated air enters   
					the cooker hood through the grease filters. The air is   
					cleaned by passing through the charcoal filters before   
					being passed back into the kitchen through the grilles in   
					either side of the chimney stack.   
					Extraction   
					In the extraction mode the contaminated air enters the   
					cooker hood passing through the grease filters and is   
					passed out through the ducting into the atmosphere.   
					To obtain the best performance when cooking it is advis-   
					able to switch the cooker hood on for a few minutes   
					before you start cooking and leave it running for about   
					15 minutes after finishing.   
					When used in the ducting mode the charcoal   
					filters are not required.   
					Never do flambé cooking under this cooker   
					hood.   
					Never leave frying pans unattended during   
					use, as over-heated fats and oils can catch fire.   
					Do not leave naked flames under the cooker   
					hood.   
					Ensure heating areas on your hob are covered   
					with pots and pans when using the hob and   
					cooker hood simultaneously.   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Maintenance and cleaning   
					Before carrying out any maintenance or   
					cleaning isolate the cooker hood from the   
					mains supply.   
					The cooker hood must be kept clean, as a   
					build up of grease or fat can be a fire hazard.   
					External cleaning   
					Wipe the cooker hood frequently with warm soapy water   
					using a mild detergent.   
					Never use scouring pads or abrasive cleaners.   
					Never use excessive amounts of water when   
					cleaning particularly around the control panel.   
					Cleaning the ducting panels   
					Disconnect by pulling only the central ducting panels.   
					Clean the outside using a damp cloth and neutral liquid   
					detergent.   
					• 
					• 
					• 
					Clean the inside using a damp cloth and neutral detergent;   
					do not use wet cloths or sponges, or jets of water; do   
					not use abrasive substances.   
					Metal grease filters   
					The grease filters absorb grease and dust during cooking   
					to help keep the cooker hood clean inside, and should   
					be cleaned when the led S1 light up or at least every 2   
					months of operation,or more frequently for particularly   
					heavy usage.   
					Cleaning the filters   
					• 
					• 
					Disconnect by pulling only the central ducting panels.   
					Remove the filters one at a time by pushing them towards   
					the back of the group and pulling down at the same   
					time.   
					• 
					The metal grease filters should be washed, by hand, in mild   
					soapy water or in a dishwasher. Allow to dry completely   
					before replacing. Any kind of bending of the filters has   
					to be avoided when washing them.   
					• 
					• 
					When fitting the filters into the hood pay attention that   
					they are mounted in the correct position and that the   
					handle faces outwards.   
					Close the ducting panels.   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Alarm signal reset   
					• Stop the motor and switch off the lights.   
					• 
					Press button T3 for at least 3 seconds, until the LEDs   
					start to flash.   
					Before carrying out any maintenance or   
					cleaning isolate the cooker hood from the   
					mains supply.   
					Charcoal filters   
					In the recirculation mode the charcoal filters absorb   
					smells and unwanted odours.   
					This charcoal filters cannot be washed or regenerated,   
					and must be replaced when the LED S1 starts to flash,   
					or at least once every 4 months.The alarm is only trig-   
					gered when the motor is on.   
					Enabling/Disabling the alarm   
					signal   
					In RecirculationVersion Hoods, the Filter saturation Alarm   
					must be enabled at the time of installation or later.   
					Switch off the lights and the motor.   
					• 
					• 
					• 
					Disconnect the mains power supply to the hood by   
					removing the motor unit power supply cable connector,   
					switching off the power supply at the Mains or turning   
					the Main switch off.   
					• 
					• 
					• 
					Restore the connection, pressing and holding T1.   
					Release the button. All five LEDs are turned on   
					Within 3 seconds press T1 until LEDs T1 and T4 flash   
					in confirmation:   
					• 
					LED flashes twice - Activated charcoal filter saturation   
					alarm ENABLED   
					• 
					LED flashes once - Activated charcoal filter saturation   
					alarm DISABLED   
					To Remove/Replace the char-   
					coal filters   
					• 
					• 
					• 
					Disconnect by pulling only the central ducting panels.   
					First remove the metal grease filters.   
					Remove the saturated charcoal filter as shown in the   
					drawing (A)   
					B 
					A 
					• 
					Position the new charcoal filter as shown in the drawing   
					(B).   
					• 
					• 
					Replace the metal grease filters.   
					Close the ducting panels.   
					12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Reset the alarm signal   
					• Stop the motor and switch off the lights.   
					• 
					Press button T3 for at least 3 seconds, until the LEDs   
					start to flash.   
					This appliance can be a possible fire hazard if   
					the grease and charcoal filters are not cleaned   
					and replaced as recommended.   
					Changing the halogen spot   
					lamp   
					• 
					• 
					Remove the lamp from the holder by pulling the lamp   
					downwards.   
					Replace the lamp with a new one of the same type,   
					making sure that you insert the two pins properly into   
					the housing on the lamp holder.   
					• 
					Replace the light cover, fixing it in place with the screws   
					removed as above.   
					Replacement filters and light bulbs can be ob-   
					tained from your local Service Force Centre.   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Something not working   
					If the appliance is not working correctly, please carry out the following checks, before contacting your local Service   
					Force agent.   
					IMPORTANT:If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or instal-   
					lation, a charge will be made even if the appliance is under guarantee.   
					Symptom   
					Solution   
					The cooker hood will not start   
					• 
					• 
					Check the hood is connected to the electricity supply.   
					Make sure the switch is in the ‘ON’ position.   
					The cooker hood is not working effectively   
					• 
					• 
					• 
					Check that the fan speed is set high enough for the task   
					Ensure the grease filter is clean.   
					Ensure the kitchen is adequately vented to allow the entry   
					of fresh air.   
					• 
					• 
					If set up for recirculation, check that the charcoal filter is   
					still effective.   
					If set up for extraction,check that the ducting and outlets   
					are not blocked.   
					The cooker hood has switched off during   
					operation   
					• 
					• 
					The safety cut-out device has been tripped.   
					Turn off the hob and then wait for the device to reset.   
					Repairs and after sales service   
					In the event of your appliance requiring service, or if   
					you wish to purchase spare parts, please contact our   
					extended warranty administrators by telephoning:   
					When you contact the Service Force Centre you will   
					need to give the following details:   
					1. Your name, address and post code   
					2. Your telephone number   
					3. Clear and concise details of fault   
					4. The model and serial number of the appliance (found   
					on the rating plate - see picture)   
					0870 01 07887   
					They will give you details for your local Service Force Centre.   
					Before calling out an engineer, please ensure you have   
					read the details under the heading “Something Not   
					Working”.   
					5. The purchase date.   
					Please note that a valid purchase receipt is required for   
					in-guarantee service calls.   
					Your oven is covered by a 3 year parts and labour   
					guarantee (see separate details given at point of sale).   
					Please retain your purchase receipt safely for the service   
					engineer to verify the purchase details.   
					14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Download from Www.Somanuals.com. All Manuals Search And Download.   
				John Lewis Partnership   
					171 Victoria Street   
					London SW1E 5NN   
					
					436004228_04 - 080703   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |