Intel Server SE7230NH1 E User Manual

®
®
Intel Server Board SE7230NH1-E and  
Intel Server Platform SR1475NH1-E  
User’s Guide  
Intel Order Number D23185-004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
About this Manual  
Thank you for purchasing and using the Intel® Server Board SE7230NH1-E.  
This manual is written for system technicians who are responsible for troubleshooting,  
upgrading, and repairing this server board. This document provides a brief overview of  
the features of the board/chassis, a list of accessories or other components you may need,  
troubleshooting information, and instructions on how to add and replace components on  
the Intel Server Board SE7230NH1-E User Guide. For the latest version of this manual,  
Manual Organization  
Chapter 1 provides a brief overview of the Server Board SE7230NH1-E. In this chapter,  
you will find a list of the server board features, drawings of the product, and product  
diagrams to help you identify components and their locations.  
Chapter 2 provides instructions on using the utilities that are shipped with the board or  
that may be required to update the system. This includes how to navigate through the  
BIOS Setup screens, how to perform a BIOS update, and how to reset the password or  
CMOS. Information about the specific BIOS settings and screens is available in the  
Technical Product Specification. See "Additional Information and Software" for a link to  
the Technical Product Specification.  
Chapter 3 provides instructions on adding and replacing components. Use this chapter for  
step-by-step instructions and diagrams for installing or replacing components such as the  
memory, processor, control panel board, and the battery, among other components.  
Chapter 4 provides troubleshooting information. In this chapter, you will find BIOS error  
messages and POST code messages. You will also find suggestions for performing  
troubleshooting activities to identify the source of a problem.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Accessories  
This server board is compatible with the following Intel® Server Chassis:  
Intel® Server Chassis SR1475  
Intel® Server Platform SR1475NH1-E  
You may need or want to purchase one or more of the following accessory items for your  
server:  
Processor, memory DIMMs, hard drive, floppy drive, CD-ROM or DVD-ROM drive,  
RAID controller, operating system.  
For information about which accessories, memory, processors, and third-party hardware  
have been tested and can be used with your board, and for ordering information for Intel  
compat.htm.  
Additional Information and Software  
If you need more information about this product or information about the accessories that  
can be used with this server board, use the following resources. These files are available  
Unless otherwise indicated in the table below, once on this Web page, type the document  
or software name in the search field at the left side of the screen and select the option to  
search "SE7230NH1-E”.  
For this information or software  
Use this Document or Software  
For in-depth technical information about this  
product, including BIOS settings and chipset  
information  
Intel® Server Board SE7230NH1-E Technical  
Product Specification  
If you just received this product and need to  
install it  
Intel® Server Board SE7230NH1-E Quick  
Start User's Guide in the product box  
For virtual system tours and interactive repair  
information  
A link to the SMaRT Tool is available under  
"Other Resources" at the right side of the  
motherboards/server/SE7230NH1-E  
Accessories or other Intel server products  
Spares and Configuration Guide  
Hardware (peripheral boards, adapter cards) and Tested HardwareOperating Systems List  
operating systems that have been tested with this  
product  
Chassis that have been tested with this product  
Reference Chassis List  
Supported Processors  
Processors that have been tested with this  
product  
DIMMs that have been tested with this product  
Tested Memory List  
To make sure your system falls within the allowed Power Budget Tool  
power budget  
®
®
iv  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For software to manage your Intel® server  
For drivers  
Intel Server Management Software  
Driver (for an extensive list of drivers  
available)  
Operating System Driver (for operating  
system drivers)  
For firmware and BIOS updates, or BIOS  
recovery  
Firmware Updates  
For diagnostics test software  
Diagnostics  
See also the Intel® Server Deployment  
Toolkit CD that came with your server board  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
®
vi  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Information  
Important Safety Instructions  
Read all caution and safety statements in this document before performing any of the  
instructions. See also Intel Server Boards and Server Chassis Safety Information on the  
Intel® Server Deployment Toolkit CD and/or at http://support.intel.com/support/  
motherboards/server/sb/cs-010770.htm.  
Wichtige Sicherheitshinweise  
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor  
Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu  
Intel-Serverplatinen und Servergehäusen auf der Intel® Server Deployment Toolkit CD  
Consignes de sécurité  
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce  
document avant de suivre toute instruction. Consultez Intel Server Boards and Server  
Chassis Safety Information sur le Intel® Server Deployment Toolkit CD ou bien rendez-  
Instrucciones de seguridad importantes  
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar  
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety  
Information en el Intel® Server Deployment Toolkit CD y/o en http://support.intel.com/  
support/motherboards/server/sb/cs-010770.htm.  
重要安全指导  
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或  
Boards and Server Chassis Safety Information(《Intel  
服务器主板与服务器机箱安全信息》)。  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Information  
Warnings  
Heed safety instructions: Before working with your server product, whether you are  
using this guide or any other resource as a reference, pay close attention to the safety  
instructions. You must adhere to the assembly instructions in this guide to ensure and  
maintain compliance with existing product certifications and approvals. Use only the  
described, regulated components specified in this guide. Use of other products /  
components will void the UL listing and other regulatory approvals of the product and  
will most likely result in noncompliance with product regulations in the region(s) in which  
the product is sold.  
System power on/off: The power button DOES NOT turn off the system AC power. To  
remove power from system, you must unplug the AC power cord from the wall outlet.  
Make sure the AC power cord is unplugged before you open the chassis, add, or remove  
any components.  
Hazardous conditions, devices and cables: Hazardous electrical conditions may be  
present on power, telephone, and communication cables. Turn off the server and  
disconnect the power cord, telecommunications systems, networks, and modems attached  
to the server before opening it. Otherwise, personal injury or equipment damage can  
result.  
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,  
boards, and other parts. We recommend that you perform all procedures in this chapter  
only at an ESD workstation. If one is not available, provide some ESD protection by  
wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on  
your server when handling parts.  
ESD and handling boards: Always handle boards carefully. They can be extremely  
sensitive to ESD. Hold boards only by their edges. After removing a board from its  
protective wrapper or from the server, place the board component side up on a grounded,  
static free surface. Use a conductive foam pad if available but not the board wrapper. Do  
not slide board over any surface.  
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips  
over two jumper pins. Some jumpers have a small tab on top that you can grip with your  
fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a  
tab, take care when using needle nosed pliers to remove or install a jumper; grip the  
narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides  
can damage the contacts inside the jumper, causing intermittent problems with the  
function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or  
other tool you use to remove a jumper, or you may bend or break the pins on the board.  
®
®
viii  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
About this Manual ................................................................................................................. iii  
Manual Organization ............................................................................................................. iii  
Product Accessories ............................................................................................................. iv  
Additional Information and Software ..................................................................................... iv  
Important Safety Instructions ............................................................................................... vii  
Wichtige Sicherheitshinweise .............................................................................................. vii  
Consignes de sécurité ......................................................................................................... vii  
Instrucciones de seguridad importantes .............................................................................. vii  
Warnings.............................................................................................................................. viii  
Server Board Features ...............................................................................................1  
Connector and Header Locations ..........................................................................................4  
Configuration Jumpers ...........................................................................................................5  
Back Panel Connectors .........................................................................................................6  
Hardware Requirements ........................................................................................................7  
Processor .................................................................................................................................... 7  
Memory ....................................................................................................................................... 7  
Power Supply .............................................................................................................................. 8  
Optional Hardware .................................................................................................................8  
Hard Disk Drives ......................................................................................................................... 8  
Server Utilities ............................................................................................................9  
Using the BIOS Setup Utility ..................................................................................................9  
Starting Setup ............................................................................................................................. 9  
If You Cannot Access Setup ....................................................................................................... 9  
Setup Menus ............................................................................................................................... 9  
Upgrading the BIOS .............................................................................................................11  
Preparing for the Upgrade ........................................................................................................ 11  
Upgrading the BIOS .................................................................................................................. 12  
Clearing the CMOS ..............................................................................................................12  
Hardware Installations and Upgrades ....................................................................13  
Before You Begin .................................................................................................................13  
Tools and Supplies Needed ...................................................................................................... 13  
Installing and Removing Memory ........................................................................................13  
Installing DIMMs ....................................................................................................................... 14  
Removing DIMMs ..................................................................................................................... 15  
Installing or Replacing the Processor ..................................................................................15  
Installing the Processor ............................................................................................................ 15  
Installing the Active Heat Sink .................................................................................................. 18  
Installing the Passive Heat Sink ............................................................................................... 19  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a Processor ............................................................................................................. 20  
Replacing the Backup Battery ............................................................................................. 21  
Troubleshooting ........................................................................................................23  
Resetting the System .......................................................................................................... 23  
Problems following Initial System Installation ...................................................................... 23  
Hardware Diagnostic Testing .............................................................................................. 24  
Verifying Proper Operation of Key System Lights .................................................................... 25  
Confirming Loading of the Operating System ........................................................................... 25  
Specific Problems and Corrective Actions .......................................................................... 25  
Power Light Does Not Light ...................................................................................................... 26  
No Characters Appear on Screen ............................................................................................ 26  
Characters Are Distorted or Incorrect ....................................................................................... 27  
System Cooling Fans Do Not Rotate Properly ......................................................................... 27  
Diskette Drive Activity Light Does Not Light ............................................................................. 28  
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light ............................................ 28  
Cannot Connect to a Server ..................................................................................................... 28  
Problems with Network ............................................................................................................. 29  
Devices are not Recognized under Device Manager .............................................................. 31  
LED Information ........................................................................................................................ 31  
BIOS POST Beep Codes ......................................................................................................... 32  
A Getting Help ..........................................................................................................33  
World Wide Web ................................................................................................................. 33  
Telephone ........................................................................................................................... 33  
B Safety Information ................................................................................................37  
English ................................................................................................................................. 37  
Server Safety Information ......................................................................................................... 37  
Safety Warnings and Cautions ................................................................................................. 37  
Intended Application Uses ........................................................................................................ 38  
Site Selection ............................................................................................................................ 38  
Equipment Handling Practices ................................................................................................. 38  
Power and Electrical Warnings ................................................................................................. 38  
System Access Warnings ......................................................................................................... 39  
Rack Mount Warnings .............................................................................................................. 40  
Electrostatic Discharge (ESD) .................................................................................................. 40  
Other Hazards .......................................................................................................................... 41  
Sicherheitshinweise für den Server .......................................................................................... 42  
Sicherheitshinweise und Vorsichtsmaßnahmen ....................................................................... 42  
Zielbenutzer der Anwendung .................................................................................................... 43  
Standortauswahl ....................................................................................................................... 43  
Handhabung von Geräten ........................................................................................................ 43  
Warnhinweise für den Systemzugang ...................................................................................... 45  
Elektrostatische Entladungen (ESD) ........................................................................................ 46  
Andere Gefahren ...................................................................................................................... 47  
Français ............................................................................................................................... 48  
®
®
x
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Consignes de sécurité sur le serveur ....................................................................................... 48  
Sécurité: avertissements et mises en garde ............................................................................. 48  
Domaines d’utilisation prévus ................................................................................................... 49  
Sélection d’un emplacement ..................................................................................................... 49  
Pratiques de manipulation de l’équipement .............................................................................. 49  
Décharges électrostatiques†(ESD) .......................................................................................... 52  
Autres risques ........................................................................................................................... 53  
Información de seguridad del servidor ...................................................................................... 54  
Advertencias y precauciones sobre seguridad ......................................................................... 54  
Aplicaciones y usos previstos ................................................................................................... 55  
Selección de la ubicación ......................................................................................................... 55  
Manipulación del equipo ........................................................................................................... 55  
Advertencias el acceso al sistema ............................................................................................ 57  
Descarga electrostática (ESD) ................................................................................................. 58  
C Regulatory and Compliance Information ...........................................................65  
Product Regulatory Compliance ..........................................................................................65  
Product Safety Compliance ...................................................................................................... 65  
Product EMC Compliance - Class A Compliance ..................................................................... 65  
Certifications / Registrations / Declarations .............................................................................. 66  
Product Regulatory Compliance Markings ............................................................................... 66  
Electromagnetic Compatibility Notices ................................................................................67  
FCC (USA) ................................................................................................................................ 67  
Industry Canada (ICES-003) .................................................................................................... 68  
Europe (CE Declaration of Conformity) .................................................................................... 68  
Taiwan Declaration of Conformity (BSMI) ................................................................................ 68  
Korean Compliance (RRL) ........................................................................................................ 69  
®
D Intel Server Issue Report Form ........................................................................71  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
®
xii  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Figures  
Figure 1. Intel® Server Board SE7230NH1-E............................................................................. 1  
Figure 2. Server Board Connector and Component Locations .................................................. 4  
Figure 3. DDR vs. DDR2 DIMMs.............................................................................................. 13  
Figure 4. Installing DIMMs........................................................................................................ 14  
Figure 5. Lift Processor Socket Lever ...................................................................................... 16  
Figure 6. Lift Processor Load Plate.......................................................................................... 16  
Figure 7. Removing Protective Processor Cover ..................................................................... 17  
Figure 8. Installing the Processor............................................................................................. 17  
Figure 9. Removing the Socket Protective Cover .................................................................... 17  
Figure 10. Closing the Load Plate and Socket Lever............................................................... 18  
Figure 11. Installing the Active Heat Sink................................................................................. 19  
Figure 12. Installing the Passive Heat Sink.............................................................................. 20  
Figure 13. Removing the Battery.............................................................................................. 22  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
®
xiv  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Tables  
Table 1. Server Board Features................................................................................................ 2  
Table 2. Configuration Jumpers ................................................................................................. 5  
Table 3. LED Information ........................................................................................................... 6  
Table 4. Keyboard Commands................................................................................................. 10  
Table 5. LED Information ......................................................................................................... 31  
Table 6. POST Error Beep Codes............................................................................................ 32  
Table 7. Product Certification Markings ................................................................................... 66  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
xv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
®
xvi  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Server Board Features  
This chapter briefly describes the main features of the Intel® Server Board SE7230NH1-  
E. This chapter provides drawings of the product, a list of the server board features, and  
diagrams showing the location of important components and connections on the server  
board.  
Sys Fan1  
12V CPU Power  
B
D
C
E
A
CPU Fan  
Sys Fan 2  
Intrusion  
P
CPU  
Main Power  
Socket  
O
Serial ATA  
N
Front Panel  
M
5
6
7
8
SCSI LED  
Serial ATA  
J
I
I
D
E
H
Sys Fan 3  
G
Sys Fan 4  
F
L
Floppy  
Sys Fans  
K
TP01795  
Figure 1. Intel® Server Board SE7230NH1-E  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1 summarizes the features of the server board.  
Table 1. Server Board Features  
Feature  
Processor  
Description  
®
®
®
®
Support for one Intel Pentium D, Pentium 4 or Celeron D  
processor in the LGA775 package  
®
Capable of 1066 MT/s on system bus when using the Intel  
®
Pentium 4 Processor Extreme Edition supporting Hyper-  
Threading Technology  
Supports Intel® Dual Core Architecture  
Supports Intel® Hyper-Threading Technology  
Supports Intel® Extended Memory System 64 Technology  
(EM64T)  
Memory  
4 DIMM sockets supporting 400/533/667MHz DDR2 DIMMs  
Data bandwidth per channel of 4.2GB/s or 8.4GB/s in dual  
channel when using DDR2 667MHz  
Support for up to two DDR2 channels for a total of 4 DIMMs (2  
DIMMs / Channel) providing up to 8GB max memory capacity  
Intel® E7230 Chipset  
Components  
Intel® E7230 MCH Memory Controller Hub  
Intel® ICH7R I/O controller  
Intel® 6702 PXH-V-V PCI-X Hub (LX SKU only)  
12-deep In-Order Queue  
I/O Control  
LC Super I/O = SMsC* LP47M182NR  
LX Super I/O = National Semiconductor* PC8374LOIBU  
External connections:  
Stacked PS2 Keyboard/Mouse connections  
RJ45 Serial B port  
Two RJ45 NIC connectors for 10/100/1000 Mb connections  
Two USB 2.0 ports  
Internal connections:  
One USB port header which supports two USB 2.0 ports  
One DH10 Serial A header  
Two SATA-150 connectors with integrated RAID 0/1 support  
One ATA-100 connector  
SSI-compliant 34-pin control panel header  
Video  
Integrated stand-alone ATI ES1000 graphics engine that supports  
standard SVGA drivers with analog display capabilities. The graphics  
subsystem has 16 MB of dedicated memory to support the onboard  
video controller  
2
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1. Server Board Features  
Feature  
Description  
Five independent PCI Buses:  
LX Board I/O Subsystem  
Segment A - Two PCI 32-bit/33-MHz 3.3V Universal connectors  
supporting full length PCI add-in cards (Adapters which support  
5V only are not supported) and one embedded Intel® 10/100/  
1000 82541PI gigabit Ethernet Controller (Supports PCI  
Specification, Rev 2.3)  
Segment B - One x1 PCI Express resource implemented as a  
single x4 PCI Express connector supporting x1/x2/x4 PCI  
Express add-in cards  
Segment C - One x1 PCI Express resource implemented as an  
embedded Intel® 10/100/1000 82573E gigabit Ethernet  
Controller  
Segment D - One x4 PCI Express resource supporting PXH-V-V  
PCI-X Hub. PXH-V-V supports one dedicated PCI-X 64/100MHz  
slot and PCI-X portion of the Intel Adaptive Slot  
Segment E - One x8 PCI Express resource supporting PCI  
Express portion of Intel Adaptive Slot. Supports x1/x2/x4/x8 PCI  
Express add-in cards via riser card  
LC Board I/O Subsystem  
Five independent PCI Buses:  
Segment A - Two PCI 32-bit/33-MHz 3.3V Universal connectors  
supporting full length PCI add-in cards (Adapters which support  
5V only are not supported) and one embedded Intel® 10/100/  
1000 82541PI gigabit Ethernet Controller (Supports PCI  
Specification, Rev 2.3)  
Segment B - One x1 PCI Express resource implemented as a  
single x4 PCI Express connector supporting x1/x2/x4 PCI  
Express add-in cards  
Segment C - One x1 PCI Express resource implemented as an  
embedded Intel® 10/100/1000 82573E gigabit Ethernet  
Controller  
Segment D - One x4 PCI Express resource implemented as a  
single x8 PCI Express connector supporting x1/x2/x4/x8 PCI  
Express add-in cards  
Segment E - One x8 PCI Express resource implemented as a  
single x8 PCI Express connector supporting x1/x2/x4/x8 PCI  
Express add-in cards  
Hard drive  
Fans  
Ultra ATA100 support: One IDE channel capable of supporting  
up to two drives.  
SATA support: Four independent SATA ports support data  
transfer rates up to 1.5 Gb/s (150MB/s) per port  
Two general purpose 3-pin fan headers  
Two general purpose 4-pin fan headers  
One 4-pin processor fan header (active heatsink required)  
Four 8-pin dual rotor fan headers for Intel High Density  
applications (Intel Server Chassis SR1475 and Intel Server  
Platform SR1475NH1-E)  
Other  
Intel Light Guided Diagnostic LED’s to display POST code indicators  
during boot (LX version only)  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector and Header Locations  
A B C D  
E
F
G H I  
J
K
L
M
N
O
P
Q
MM  
LL  
KK  
JJ  
II  
HH  
BB  
AA Z X  
Y W U  
GG  
FF EE DD CC  
V
T
S
R
TP01781  
A. Intrusion Header  
N. SysFan1  
O. SysFan2  
AA.PATA IDE Connector  
BB.SysFan3  
B. PCI (32bit/33MHz) Slot 1  
C. PCI (32bit/33MHz) Slot 2  
P. 2x4 Processor Power  
Q. Processor Fan  
CC.Floppy Connector  
DD.SCSI LED Connector  
D. PCI Express* x4 (x1 Lane)  
Slot 3  
E. PCI Express* x8 (x4 Lane)  
Slot 4  
R. Memory Bank 2  
EE.SATA Port 3  
F. PCI-X (64bit/100MHz) Slot 5 - S. Memory Bank 1  
LX version only  
FF.SATA Port 2  
G. PCI Express* x8 (x8 Lane)  
Slot 6 - LC version only; Riser  
Card Slot - LX version only  
T. Main Power  
GG.Clear CMOS Jumper  
H. Battery  
U. Hardware Management  
Controller  
HH.Front Panel Connector  
I. Processor Socket  
J. NIC1 and USB1-2  
K. NIC2  
V. SysFan8 - LX version only  
W. SysFan7 - LX version only  
X. SysFan6 - LX version only  
Y. SysFan5 - LX version only  
II. SATA Port 1  
JJ.SATA Port 0  
KK.External USB Connector  
LL.CMOS Config Jumper  
MM.HSBP Connector  
L. Serial A and Video Port  
M. PS2 Stacked Mouse/Keyboard Z. SysFan4  
Figure 2. Server Board Connector and Component Locations  
4
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Jumpers  
CMOS Configuration  
Jumper (J9H3)  
3
Config  
A
2
Normal  
Off - Recovery  
Clear CMOS  
Jumper (J9G3)  
3
B
Clear  
2
Normal  
TP01794  
Table 2. Configuration Jumpers  
Jumper Name  
What happens at system reset...  
Pins 1-2 should be jumpered for normal system operation.  
CMOS Configuration  
If pins 2-3 are jumpered, the system will enter a configuration menu  
that is only available by jumpering these pins. These pins should not  
be jumpered for normal operation.  
If the jumper is removed, the system will attempt to recover the BIOS  
by loading the BIOS code into the flash device from a floppy disk.  
This is typically used when the BIOS has become corrupted. The  
jumper should not be removed for normal operation.  
Clear CMOS  
Pins 1-2 should be jumpered for normal system operation.  
If pins 2-3 are jumpered, the CMOS settings will be cleared on the  
next reset. These pins should not be jumpered for normal operation.  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Back Panel Connectors  
E
B
C
A
D
F
TP01783  
A. Stacked PS2 Mouse/Keyboard Ports  
B. Serial A  
C. Video  
D. NIC2 (10/100/1000Mb)  
E. NIC1 (10/100/1000Mb)  
F. USB1-2  
The NIC LEDs at the right and left of each NIC provide the following information.  
Table 3. LED Information  
LED  
LED State  
Description  
No network connection  
Left  
Off  
Solid Amber  
Blinking Amber  
Off  
Network connection in place  
Transmit/receive activity  
Right  
10 Mbps connection (if left LED is on or blinking)  
100 Mbps connection  
Solid Amber  
Solid Green  
1000 Mbps connection  
6
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Requirements  
To avoid integration difficulties and possible board damage, your system must meet the  
requirements outlined below. For a list of qualified components, see the links under  
"Additional Information and Software."  
Processor  
One Intel® Pentium® 4 processor, Pentium® D processor, Celeron® D processor, or  
Pentium® processor Extreme Edition. For a complete list of supported processors, see the  
links under "Additional Information and Software."  
Memory  
The Server Board SE7230NH1-E provides four DIMM sockets across two channels,  
Channel A and Channel B. Channel A consists of DIMM sockets 1A and 2A. Channel B  
consists of DIMM sockets 1B and 2B.  
A minimum of one 256MB DIMM is required in DIMM socket 1A. This uses single-  
channel interleave. However, for dual-channel interleave, providing optimum  
performance, a minimum of two DIMMs should be installed in DIMM sockets 1A and  
1B. Except for the option of installing a single DIMM in socket 1A or 1B, DIMMs must  
be installed in pairs and populated as follows:  
DIMM1A and DIMM 1B: Populate these two sockets together first.  
DIMM 2A and DIMM 2B: Populate these sockets in addition to DIMM 1A and  
DIMM 1B if four DIMMs are to be used.  
DIMMs must meet the following requirements:  
DDR2 400/533/667 , un-buffered, DDR2 DIMM modules  
DIMM organization: x72 ECC or x 64 Non-ECC  
Pin count: 240  
DIMM capacity: 256 MB, 512 MB, 1 GB and 2 GB DIMMs  
Serial PD: JEDEC Rev 2.0  
Serial PD: JEDEC Rev 2.0  
Interface: SSTL2  
For a complete list of supported memory DIMMs, see the links under "Additional  
Information and Software."  
In order to operate in Dual Channel Dynamic Paging Mode, the following conditions must  
be met:  
• Two identical DIMMs are installed, one each in DIMM_1A and DIMM_1B  
• Four identical DIMMs are installed (one in each socket location)  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing only 3 DIMMs is not supported. Do not use DIMMs that are not “matched”  
(same type and speed). Use of identical memory parts is always the preferred method.See  
the Intel® Server Board SE7230NH1-E Technical Product Specification for additional  
information regarding the memory sub-system.  
Power Supply  
A minimum of 350 Watts is required. Your supply must provide a minimum of 1.2A of 5V  
standby current or the board will not boot.  
Optional Hardware  
Hard Disk Drives  
The Server Board SE7230NH1-E supports up to four SATA devices.  
See the documentation included with your server chassis for additional drive information  
and drive installation instructions.  
8
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Server Utilities  
Using the BIOS Setup Utility  
This section describes the BIOS Setup Utility options, which is used to change server  
configuration defaults. You can run BIOS Setup with or without an operating system  
being present. See “Additional Information and Software” for a link to the Technical  
Product Specification where you will find details about specific BIOS setup screens.  
Starting Setup  
You can enter and start BIOS Setup under several conditions:  
When you turn on the server, after POST completes the memory test  
When you have moved the CMOS jumper on the server board to the “Clear CMOS”  
position (enabled)  
In the two conditions listed above, during the Power On Self Test (POST), you will see  
this prompt:  
Press <F2> to enter SETUP  
In a third condition, when CMOS/NVRAM has been corrupted, you will see other  
prompts but not the <F2> prompt:  
Warning: CMOS checksum invalid  
Warning: CMOS time and date not set  
In this condition, the BIOS will load default values for CMOS and attempt to boot.  
If You Cannot Access Setup  
If you are not able to access BIOS Setup, you might need to clear the CMOS memory. For  
instructions on clearing the CMOS, see “Clearing the CMOS”.  
Setup Menus  
Each BIOS Setup menu page contains a number of features. Except for those features that  
are provided only to display automatically configured information, each feature is  
associated with a value field that contains user-selectable parameters. These parameters  
can be changed if the user has adequate security rights. If a value cannot be changed for  
any reason, the feature’s value field is inaccessible.  
Table 4 describes the keyboard commands you can use in the BIOS Setup menus.  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 4. Keyboard Commands  
Press  
Description  
<F1>  
Help - Pressing F1 on any menu invokes the general Help window.  
← →  
The left and right arrow keys are used to move between the major menu pages. The keys  
have no affect if a submenu or pick list is displayed.  
¦
Select Item up - The up arrow is used to select the previous value in a menu item’s option list,  
or a value field pick list. Pressing the Enter key activates the selected item.  
Ø
Select Item down - The down arrow is used to select the next value in a menu item’s option  
list, or a value field pick list. Pressing the Enter key activates the selected item.  
F5/-  
Change Value - The minus key or the F5 function key is used to change the value of the  
current item to the previous value. This key scrolls through the values in the associated pick  
list without displaying the full list.  
F6/+  
Change Value - The plus key or the F6 function key is used to change the value of the current  
menu item to the next value. This key scrolls through the values in the associated pick list  
without displaying the full list. On 106-key Japanese keyboards, the plus key has a different  
scan code than the plus key on the other keyboard, but it has the same effect.  
<Enter>  
<Esc>  
Execute Command - The Enter key is used to activate submenus when the selected feature is  
a submenu, or to display a pick list if a selected feature has a value field, or to select a sub-  
field for multi-valued features like time and date. If a pick list is displayed, the Enter key will  
undo the pick list, and allow another selection in the parent menu.  
Exit - The ESC key provides a mechanism for backing out of any field. This key will undo the  
pressing of the Enter key. When the ESC key is pressed while editing any field or selecting  
features of a menu, the parent menu is re-entered. When the ESC key is pressed in any  
submenu, the parent menu is re-entered. When the ESC key is pressed in any major menu,  
the exit confirmation window is displayed and the user is asked whether changes can be  
discarded.  
<F9>  
Setup Defaults - Pressing F9 causes the following to appear:  
Setup Confirmation  
Load default configuration now?  
[Yes] [No]  
If “Yes” is selected and the Enter key is pressed, all Setup fields are set to their default values.  
If “No” is selected and the Enter key is pressed, or if the ESC key is pressed, the user is  
returned to where they were before F9 was pressed without affecting any existing field values.  
<F10>  
Save and Exit - Pressing F10 causes the following message to appear:  
Setup Confirmation  
Save Configuration changes and exit now?  
[Yes] [NO]  
If “Yes” is selected and the Enter key is pressed, all changes are saved and Setup is exited. If  
“No” is selected and the Enter key is pressed, or the ESC key is pressed, the user is returned  
to where they were before F10 was pressed without affecting any existing values.  
10  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Upgrading the BIOS  
The upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in  
the upgrade file include the following:  
On-board system BIOS, including the recovery code, BIOS Setup Utility, and strings.  
On-board video BIOS, SCSI BIOS, and other option ROMs for devices embedded on  
the server board.  
OEM binary area  
Microcode  
A way to change the BIOS language  
Preparing for the Upgrade  
The steps below explain how to prepare to upgrade the BIOS, including how to record the  
current BIOS settings and how to obtain the upgrade utility.  
Note: In the unlikely event that a BIOS error occurs during the BIOS update process, a recovery  
process may need to be followed to return the system to service. See “Additional  
Information and Software” for a link to necessary software and instrutions.  
Recording the Current BIOS Settings  
1. Boot the computer and press <F2> when you see the message:  
Press <F2> Key if you want to run SETUP  
2. Write down the current settings in the BIOS Setup program.  
Note: Do not skip step 2. You will need these settings to configure your computer at the end of  
the procedure.  
Obtaining the Upgrade  
Download the BIOS image file to a temporary folder on your hard drive. See “Additional  
Information and Software” for a link to the update software.  
Note: Review the instructions and release notes that are provided in the readme file distributed  
with the BIOS image file before attempting a BIOS upgrade. The release notes contain  
critical information regarding jumper settings, specific fixes, or other information to  
complete the upgrade.  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Upgrading the BIOS  
Follow the instructions in the readme file that came with the BIOS upgrade. When the  
update completes, remove the bootable media from which you performed the upgrade.  
Note: Do not power down the system during the BIOS update process! The system will reset  
automatically when the BIOS update process is completed.  
Note: You may encounter a CMOS Checksum error or other problem after reboot. If this  
happens, shut down the system and boot it again. CMOS checksum errors require that you  
enter Setup, check your settings, save your settings, and exit Setup.  
Clearing the CMOS  
If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to  
be used to reset the configuration RAM.  
1. Power down the system and disconnect the AC power.  
2. Open the server and move the jumper from the normal operation position, at pins 1  
and 2, to the CMOS Clear position covering pins 2 and 3 as indicated in the following  
diagram.  
CMOS Configuration  
Jumper (J9H3)  
3
Config  
A
2
Normal  
Off - Recovery  
Clear CMOS  
Jumper (J9G3)  
3
B
Clear  
2
Normal  
TP01794  
3. Reconnect the AC power, and wait a few seconds. The standby power delivered to the  
server at this stage will clear the CMOS.  
4. Disconnect the AC power and return the CMOS Clear jumper to the Normal location,  
covering pins 1 and 2.  
5. Close the server chassis, reconnect the AC power, and power up the system.  
12  
Intel® Server Board SE7230NH1-E and Intel® Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 Hardware Installations and  
Upgrades  
Before You Begin  
Before working with your server product, pay close attention to the “Safety Information”  
at the beginning of this manual.  
Tools and Supplies Needed  
Phillips* (cross head) screwdriver (#1 bit and #2 bit)  
Needle nosed pliers  
Antistatic wrist strap and conductive foam pad (recommended)  
Installing and Removing Memory  
The silkscreen on the board for the DIMMs displays DIMM_2B, DIMM_1B, DIMM_2A,  
DIMM_1A starting from the edge of the board. DIMM_1A is the socket closest to the  
processor socket. See "Memory" for a discussion of the memory requirements and  
options. See "Additional Information and Software" for a link to the list of tested DIMMs.  
Note: The DIMMs being installed must be DDR2 DIMMs (see letter “A” in Figure 3). DDR  
DIMMs will not physically fit into a server board designed to support DDR2 DIMMs (see  
letter “B” in Figure 3).  
Figure 3. DDR vs. DDR2 DIMMs  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing DIMMs  
To install DIMMs, follow these steps:  
1. Observe the safety and ESD precautions in “Safety Information”.  
2. Turn off all peripheral devices connected to the server. Turn off the server.  
3. Disconnect the AC power cord from the server.  
4. Remove the server's cover. See the documentation that came with your server chassis  
for instructions on removing the server's cover.  
5. Locate the DIMM sockets (see Figure 4).  
C
D
B
A
DIMM 2B  
Socket  
DIMM 1A  
Socket  
DIMM 2A  
Socket  
DIMM 1B  
Socket  
TP01784  
Figure 4. Installing DIMMs  
6. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the  
open position (see letter “A” in Figure 4).  
7. Holding the DIMM by the edges, remove it from its anti-static package.  
8. Position the DIMM above the socket. Align the notch on the bottom edge of the  
DIMM with the key in the DIMM socket (see letter “B” in Figure 4).  
9. Insert the bottom edge of the DIMM into the socket (see letter “C” in Figure 4).  
10. When the DIMM is inserted, push down on the top edge of the DIMM until the  
retaining clips snap into place. Make sure the clips are firmly in place (see letter “D”  
in Figure 4).  
11. Replace the server's cover and reconnect the AC power cord. See the documentation  
that came with your server chassis for instructions on installing the server's cover.  
®
®
14  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing DIMMs  
To remove a DIMM, follow these steps:  
1. Observe the safety and ESD precautions in “Safety Information”.  
2. Turn off all peripheral devices connected to the server. Turn off the server.  
3. Remove the AC power cord from the server.  
4. Remove the server's cover. See the documentation that came with your server chassis  
for instructions on removing the server's cover.  
5. Gently spread the retaining clips at each end of the socket. The DIMM lifts from the  
socket.  
6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static  
package.  
7. Reinstall and reconnect any parts you removed or disconnected to reach the DIMM  
sockets.  
8. Replace the server's cover and reconnect the AC power cord. See the documentation  
that came with your server chassis for instructions on installing the server's cover.  
Installing or Replacing the Processor  
Caution: Processor must be appropriate: You may damage the server board if you install a  
processor that is inappropriate for your server. See “Additional Information and  
Software” for a link to the list of compatible processor(s).  
Caution: ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage  
to the processor by doing the following: (1) Touch the metal chassis before touching the  
processor or server board. Keep part of your body in contact with the metal chassis to  
dissipate the static charge while handling the processor. (2) Avoid moving around  
unnecessarily.  
Installing the Processor  
To install a processor, follow these instructions:  
1. Observe the safety and ESD precautions in “Safety Information”.  
2. Turn off all peripheral devices connected to the server. Turn off the server.  
3. Disconnect the AC power cord from the server.  
4. Remove the server's cover. See the documentation that came with your server chassis  
for instructions on removing the server's cover.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Push the lever handle down and away from the socket to release it. Pull the lever and  
open all the way (see Figure 5)..  
TP01786  
Figure 5. Lift Processor Socket Lever  
6. Push the rear tab with your finger tip to bring the front end of the load plate up slightly  
(see letter “A” in Figure 6). Open the load plate as shown (see letter “B” in Figure 6).  
Do not touch the processor socket contacts (see Figure 6)..  
Figure 6. Lift Processor Load Plate  
®
®
16  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Take the processor out of the box and remove the protective shipping cover (see  
Figure 7).  
TP01789  
Figure 7. Removing Protective Processor Cover  
8. Orient the processor with the socket so that the processor cutout matches the socket  
notch (see letter “A” in Figure 8), and insert the processor into the socket (see letter  
“B” in Figure 8).  
A
B
TP01790  
Figure 8. Installing the Processor  
9. Grasp the socket protective cover tab and pull away from the load plate (see letter “A”  
in Figure 9). Remove the socket protective cover and store for future use (see letter  
“B” in Figure 9).  
A
B
TP01788  
Figure 9. Removing the Socket Protective Cover  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Close the load plate all the way (see letter “A” in Figure 10). With your finger, push  
down on the load plate as shown (see letter “B” in Figure 10). Close the socket lever  
and ensure that the load plate tab engages under the socket lever when fully closed  
(see letter “C” in Figure 10).  
A
C
B
TP01791  
Figure 10. Closing the Load Plate and Socket Lever  
Installing the Active Heat Sink  
The heat sink has Thermal Interface Material (TIM) located on the bottom of it. Use  
caution when you unpack the heat sink so you do not damage the TIM.  
1. Make sure the screwdriver slot at the top of each fastener is rotated clockwise so the  
screwdriver slot points to the center of the heat sink as shown (see letter “A” in  
Figure 11).  
2. Align the heat sink with the mounting holes in the server board and lower the  
assembly to the board (see letter “B” in Figure 11). The snaps go through the holes in  
the server board.  
3. Press downward on top of each cap (see letter “C” in Figure 11).  
®
®
18  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Ensure that the fasteners have snapped into final position (see letter “D” in Figure 11).  
Figure 11. Installing the Active Heat Sink  
5. Reinstall and reconnect any parts you removed or disconnected to reach the processor  
sockets.  
6. Replace the server's cover and reconnect the AC power cord. See the documentation  
that came with your server chassis for instructions on installing the server's cover.  
Installing the Passive Heat Sink  
If your server board is installed into the Intel Server Platform SR1475NH1-E, a custom  
copper 1U passive heat sink is installed. The heat sink must be installed with the solid  
copper sides of it facing to the left and to the right of the chassis. This is necessary  
because the air from the fans at the front of the chassis must be able to flow from front to  
back between the copper plates on the other sides of the heat sink.  
The heat sink has Thermal Interface Material (TIM) located on the bottom of it. Use  
caution when you unpack the heat sink so you do not damage the TIM.  
1. Set the heat sink over the processor, lining up the four captive screws with the four  
mounting holes surrounding the processor (see Figure 12).  
2. Loosely screw in the captive screws on the heat sink corners in a diagonal manner. Do  
no fully tighten one screw before tightening another (see Figure 12 for reference).  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Gradually and equally tighten each captive screw until each is firmly tightened.  
w
airflo  
3
2
1
4
TP01793  
Figure 12. Installing the Passive Heat Sink  
4. Reinstall and reconnect any parts you removed or disconnected to reach the processor  
sockets.  
5. Replace the server's cover and reconnect the AC power cord. See the documentation  
that came with your server chassis for instructions on installing the server's cover.  
Removing a Processor  
1. Observe the safety and ESD precautions in “Safety Information”.  
2. Turn off all peripheral devices connected to the server. Turn off the server.  
3. Remove the AC power cord from the server.  
4. Remove the server's cover. See the documentation that came with your server chassis  
for instructions on removing the server's cover.  
5. Unplug the processor fan cable from the server board.  
6. Loosen the four captive screws on the corners of the heat sink.  
7. Twist the heat sink slightly to break the seal between the heat sink and the processor.  
8. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink  
again. Do not force the heat sink from the processor. Doing so could damage the  
processor.  
9. Lift the processor lever.  
10. Press the release button and lift the load plate.  
11. Remove the processor.  
®
®
20  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. If installing a replacement processor, see “Installing the Processor”. Otherwise, close  
the load plate and lower the socket lever completely.  
13. Reinstall the chassis cover.  
Replacing the Backup Battery  
The lithium battery on the server board powers the RTC for up to 10 years in the absence  
of power. When the battery starts to weaken, it loses voltage, and the server settings  
stored in CMOS RAM in the RTC (for example, the date and time) may be wrong.  
Contact your customer service representative or dealer for a list of approved devices.  
Warning: Danger of explosion if battery is incorrectly replaced. Replace only with the same or  
equivalent type recommended by the equipment manufacturer. Discard used batteries  
according to manufacturer's instructions.  
Advarsel: Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med  
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.  
Advarsel: Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av  
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.  
Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ  
som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens  
instruktion.  
Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan  
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden  
mukaisesti.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Observe the safety and ESD precautions in “Safety Information”.  
2. Turn off all peripheral devices connected to the server. Turn off the server.  
3. Disconnect the AC power cord from the server.  
4. Remove the server's cover and locate the battery. See the documentation that came  
with your server chassis for instructions on removing the server's cover.  
5. Lift the battery retention mechanism (see Figure 13).  
6. Remove the battery from its socket.  
TP01782  
Figure 13. Removing the Battery  
7. Dispose of the battery according to local ordinance.  
8. Remove the new lithium battery from its package, and, being careful to observe the  
correct polarity, insert it in the battery socket.  
9. Close the chassis.  
10. Run Setup to restore the configuration settings to the RTC.  
®
®
22  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 Troubleshooting  
This chapter helps you identify and solve problems that might occur while you are using  
the system.  
For any issue, first ensure you are using the latest firmware and files. Firmware upgrades  
include updates for BIOS, the baseboard management controller (BMC), and the hot-swap  
controller (HSC). See “Additional Information and Software” for a link to the software  
updates. In addition to the server firmware and files, also update any drivers used for  
components you have installed in your system, such as video drivers, network drivers, and  
SCSI drivers.  
Intel provides a package called the “Platform Confidence Test” that may help with your  
diagnostics. See “Additional Information and Software” for a link to this software.  
If you are unable to resolve your server problems on your own, see “Getting Help” for  
assistance.  
Resetting the System  
Before going through in-depth troubleshooting, attempt first to perform reset your system  
using one of the methods below.  
To do this:  
Press:  
Soft boot reset to clear the system memory and reload the operating  
system.  
<Ctrl+Alt+Del>  
Clear system memory, restart POST, and reload the operating system.  
Reset button  
Power off/on  
Cold boot reset. Turn the system power off and then on. This clears  
system memory, restarts POST, reloads the operating system, and halts  
power to all peripherals.  
Problems following Initial System Installation  
Problems that occur at initial system startup are usually caused by an incorrect installation  
or configuration. Hardware failure is a less frequent cause. If the problem you are  
experiencing is with a specific software application, see “Problems with Newly Installed  
Application Software”.  
First Steps Checklist  
1. Is AC power available at the wall outlet?  
2. Are the power supplies plugged in? Check the AC cable(s) on the back of the chassis  
and at the AC source.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Are all cables correctly connected and secured?  
4. Are the processors fully seated in their sockets on the server board?  
5. Are all standoffs in the proper location and not touching any components, causing a  
potential short?  
6. Are all add-in PCI boards fully seated in their slots on the server board?  
7. Are all jumper settings on the server board correct?  
8. Are all jumper and switch settings on add-in boards and peripheral devices correct?  
To check these settings, refer to the manufacturer’s documentation that comes with  
them. If applicable, ensure that there are no conflicts—for example, two add-in  
boards sharing the same interrupt.  
9. Are all peripheral devices installed correctly?  
10. If the system has a hard disk drive, is it properly formatted or configured?  
11. Are all device drivers properly installed?  
12. Are the configuration settings made in Setup correct?  
13. Is the operating system properly loaded? Refer to the operating system  
documentation.  
14. Did you press the system power on/off switch on the front panel to turn the server on  
(power on light should be lit)?  
15. Is the system power cord properly connected to the system and plugged into a  
NEMA 5-15R outlet for 100-120 Vor a NEMA 6-15R outlet for 200-240 V?  
16. Are all integrated components from the tested components lists? Check the tested  
memory, and chassis lists, as well as the supported hardware and operating system  
list. See “Additional Information and Software” for links to the tested component  
lists.  
Hardware Diagnostic Testing  
This section provides a more detailed approach to identifying a hardware problem and  
locating its source.  
Caution: Turn off devices before disconnecting cables: Before disconnecting any peripheral  
cables from the system, turn off the system and any external peripheral devices. Failure to  
do so can cause permanent damage to the system and/or the peripheral devices.  
1. Turn off the system and all external peripheral devices. Disconnect each device from  
the system, except for the keyboard and the video monitor.  
2. Make sure the system power cord is plugged into a properly grounded AC outlet.  
3. Make sure your video display monitor and keyboard are correctly connected to the  
system. Turn on the video monitor. Set its brightness and contrast controls to at least  
two thirds of their maximum ranges (see the documentation supplied with your video  
display monitor).  
®
®
24  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. If the operating system normally loads from the hard disk drive, make sure there is no  
diskette in drive A and no CD-ROM disk in the CD-ROM drive.  
5. If the power LED does light, attempt to boot from a floppy diskette or from a CD-  
ROM disk.  
6. Turn on the system. If the power LED does not light, see “Power Light Does Not  
Light”.  
Verifying Proper Operation of Key System Lights  
As POST determines the system configuration, it tests for the presence of each mass  
storage device installed in the system. As each device is checked, its activity light should  
turn on briefly. Check for the following:  
1. Does the diskette drive activity light turn on briefly? If not, see “Diskette Drive  
Activity Light Does Not Light”.  
2. If system LEDs are illuminated, see “LED Information” for a description of the light  
and steps to take to correct the problem.  
Confirming Loading of the Operating System  
Once the system boots up, the operating system prompt appears on the screen. The  
prompt varies according to the operating system. If the operating system prompt does not  
appear, see “No Characters Appear on Screen”.  
Specific Problems and Corrective Actions  
This section provides possible solutions for these specific problems:  
1. Power light does not light.  
2. No characters appear on screen.  
3. Characters on the screen appear distorted or incorrect.  
4. System cooling fans do not rotate.  
5. Diskette drive activity light does not light.  
6. Hard disk drive activity light does not light.  
7. CD-ROM drive activity light does not light.  
8. There are problems with application software.  
9. The bootable CD-ROM is not detected.  
Try the solutions below in the order given. If you cannot correct the problem, contact  
your service representative or authorized dealer for help.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Light Does Not Light  
Check the following:  
1. Did you press the power-on button?  
2. Is the system operating normally? If so, the power LED might be defective or the  
cable from the front panel to the server board might be loose.  
3. Have you securely plugged the server AC power cord into the power supply?  
4. Is the power supply correctly set to 110 V or 235 V, depending on your power output?  
5. Will other items plugged into the same power outlet function correctly?  
6. Some ATX power supplies have a power switch on the back of the power supply, next  
to the fan. If your system as one, is it turned on?  
7. Remove all add-in cares and see if the system boots. If successful, add the cards back  
in one at a time with a reboot between each addition.  
8. Make sure the memory DIMMs comply with the system requirements.  
9. Make sure the memory DIMMs have been populated according to the system  
requirements.  
10. Remove the memory DIMMs and re-seat them.  
11. Make sure the processor(s) comply with the system requirements.  
12. Make sure the processor(s) have been populated according to the system  
requirements.  
13. Remove the processor(s) and re-seat them.  
14. Make sure the chassis standoffs are installed only below mounting holes. Misplaced  
standoffs can contact the pins on the bottom of the server board and cause a short.  
No Characters Appear on Screen  
1. Check the following:  
2. Is the keyboard functioning? Test it by turning the “Num Lock” function on and off to  
make sure the Num Lock light is functioning.  
3. Is the video monitor plugged in and turned on? If you are using a switch box, is it  
switched to the correct system?  
4. Are the brightness and contrast controls on the video monitor properly adjusted?  
5. Is the video monitor signal cable properly installed?  
6. Does this video monitor work correctly if plugged into a different system?  
7. Is the onboard video controller enabled in the BIOS?  
8. Remove all add-in cares and see if the video returns. If successful, add the cards back  
in one at a time with a reboot between each addition.  
9. Make sure the memory DIMMs comply with the system requirements.  
®
®
26  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Make sure the memory DIMMs have been populated according to the system  
requirements.  
11. Remove the memory DIMMs and re-seat them.  
12. Make sure the processor(s) comply with the system requirements.  
13. Make sure the processor(s) have been populated according to the system  
requirements.  
14. Remove the processor(s) and re-seat them.  
If you are using an add-in video controller board, do the following:  
Verify that the video works using the onboard video controller.  
Verify that the video controller board is fully seated in the server board connector.  
Reboot the system for changes to take effect.  
If there are still no characters on the screen after you reboot the system and POST  
emits a beep code, write down the beep code you hear. This information is useful for  
your service representative.  
If you do not receive a beep code and characters do not appear, the video display  
monitor or video controller may have failed. Contact your service representative or  
authorized dealer for help.  
Characters Are Distorted or Incorrect  
Check the following:  
1. Are the brightness and contrast controls properly adjusted on the video monitor? See  
the manufacturer’s documentation.  
2. Are the video monitor’s signal and power cables properly installed?  
3. Does this video monitor work correctly if plugged into a different system?  
System Cooling Fans Do Not Rotate Properly  
If the system cooling fans are not operating properly, it is an indication of possible system  
component failure.  
Check the following:  
1. Is the power-on light lit? If not, see “Power Light Does Not Light”  
2. If your system has LED lights for the fans, is one or more of these LEDs lit?  
3. Are any other front panel LEDs lit?  
4. Have any of the fan motors stopped? Use the server management subsystem to check  
the fan status.  
5. Have your fans speeded up in response to an overheating situation?  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Have your fans speeded up in response to a fan that has failed?  
7. Are the fan power connectors properly connected to the server board?  
8. Is the cable from the front panel board connected to the both the front panel board and  
to the server board?  
9. Are the power supply cables properly connected to the server board?  
10. Are there any shorted wires caused by pinched-cables or have power connector plugs  
been forced into power connector sockets the wrong way?  
Diskette Drive Activity Light Does Not Light  
Check the following:  
1. Are the diskette drive’s power and signal cables properly installed?  
2. Are all relevant switches and jumpers on the diskette drive set correctly?  
3. Is the diskette drive properly configured?  
4. Is the diskette drive activity light always on? If so, the signal cable may be plugged in  
incorrectly.  
If you are using the onboard diskette controller, use the BIOS setup to make sure that  
“Onboard Floppy” is set to “Enabled.” If you are using an add-in diskette controller,  
make sure that “Onboard Floppy” is set to “Disabled.”  
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light  
Check the following:  
1. Are the CD-ROM/DVD-ROM drive’s power and signal cables properly installed?  
2. Are all relevant switches and jumpers on the drive set correctly?  
3. Is the drive properly configured?  
Cannot Connect to a Server  
1. Make sure the network cable is securely attached to the correct connector at the  
system back panel.  
2. Try a different network cable.  
3. Make sure you are using the correct and the current drivers. See “Additional  
Information and Software” for a link to the current drivers.  
4. Make sure the driver is loaded and the protocols are bound.  
5. Make sure the hub port is configured for the same duplex mode as the network  
controller.  
6. Make sure the correct networking software is installed.  
7. If you are directly connecting two servers (without a hub), you will need a crossover  
cable.  
®
®
28  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Check the network controller LEDs next to the NIC connectors.  
Problems with Network  
The server hangs when the drivers are loaded.  
Certain drivers may require interrupts that are not shared with other PCI drivers. For these  
drivers, it may be necessary to alter settings so that interrupts are not shared. See the  
documentation that came with your PCI card(s) for information on changing interrupts.  
Diagnostics pass but the connection fails.  
1. Make sure the network cable is securely attached.  
2. Make sure you specify the correct frame type in your NET.CFG file.  
The controller stopped working when an add-in adapter was installed.  
1. Make sure the cable is connected to the port from the onboard network controller.  
2. Make sure your BIOS is current. See “Additional Information and Software” for a  
link to the current version.  
3. Make sure the other adapter supports shared interrupts. Make sure your operating  
system supports shared interrupts.  
4. Try reseating the add-in adapter.  
The add-in adapter stopped working without apparent cause.  
1. Try reseating the adapter first; then try a different slot if necessary.  
2. The network driver files may be corrupt or deleted. Delete and then reinstall the  
drivers.  
3. Run the diagnostics.  
System Boots when Installing PCI Card  
System Server Management features require full-time “standby” power. This means some  
parts of the system have power going to them whenever the power cord is plugged in,  
even if you have turned the system power off with the power button on the front panel. If  
you install a PCI card with the AC power cord plugged in, a signal may be sent to the  
command the system to boot. Before installing a PCI card, you should always:  
1. Turn off the server power by using the power button on the front of the system.  
2. Unplug the AC power cord(s) from the server.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problems with Newly Installed Application Software  
Problems that occur when you run new application software are usually related to the  
software, not the server hardware. Faulty equipment is unlikely, especially if other  
software runs correctly.  
Check the following:  
1. Make sure the system meets the minimum hardware requirements for the software.  
See the software documentation.  
2. Make sure the software is properly installed and configured for the system. See the  
software documentation.  
3. Use only an authorized copy. Unauthorized copies often do not work.  
4. If you are running the software from a diskette, CD-ROM or DVD-ROM, try a  
different diskette.  
5. Make sure the correct device drivers installed.  
If the problems persist, contact the software vendor’s customer service representative.  
Problems with Application Software that Ran Correctly Earlier  
Problems that occur after the system hardware and software have been running correctly  
sometimes indicate equipment failure. However, they can also be caused by file  
corruption or changes to the software configuration.  
Check the following:  
1. If you are running the software from a diskette, CD-ROM or DVD-ROM, try a  
different diskette.  
2. Uninstall and reinstall the software. Make sure all necessary files are installed.  
3. If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if  
keyboard input is incorrect), a marginal power supply, or other random component  
failures.  
4. If you suspect that a transient voltage spike, power outage, or brownout might have  
occurred, reload the software and try running it again. Symptoms of voltage spikes  
include a flickering video display, unexpected system reboots, and the system not  
responding to user commands.  
Note: Random errors in data files: If you are getting random errors in your data files, they may  
be getting corrupted by voltage spikes on your power line. If you are experiencing any of  
the above symptoms that might indicate voltage spikes on the power line, you may want to  
install a surge suppressor between the power outlet and the system power cord.  
®
®
30  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Devices are not Recognized under Device Manager  
The Windows* operating systems do not include all of the drivers for the Intel chipsets,  
onboard NICs, and other components. See “Additional Information and Software” for a  
link to the current drivers and chipset files.  
Hard Drive(s) are not Recognized  
Check the following:  
1. Make sure the drive is not disabled in BIOS Setup.  
2. Make sure the drive is connected correctly and that is plugged into the power supply.  
3. Make sure the drive is compatible. See “Additional Information and Software” for a  
link to the tested drives.  
4. Make sure you have not exceeded the power budget for the server. See “Additional  
Information and Software” for a link to software to check your power budget.  
5. If using SCSI drives, verify that each SCSI ID number is uniqe on the SCSI bus. See  
your drive documentation for details on setting the SCSI ID for your drives.  
6. If using IDE drives, verify that the master/slave settings are set correctly. See your  
drive documentation for details on setting the master/slave settings.  
7. If using a RAID configuration with SCSI or SATA drives, make sure the RAID card is  
installed correctly.  
Bootable CD-ROM Is Not Detected  
Check the following:  
Make sure the BIOS is configured to allow the CD-ROM to be the first bootable  
device.  
LED Information  
The Intel® Server Board SE7230NH1-E includes LEDs that can aid in troubleshooting  
your system. A table of these LEDs with a description of their use is listed below.  
Table 5. LED Information  
LED Name  
Power  
Function  
Location  
LED Color  
Green  
Notes  
Indicates system power  
is on or off  
Front control  
panel  
Off = Power is off or in  
sleep state S5  
On = Power is on or in  
sleep stats S0  
ID  
Aid in server  
identification from the  
back panel  
Front control  
panel and  
board rear left  
corner  
Blue  
Press ID LED button or use  
Server Management  
software to turn the LED on  
and off.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 5. LED Information  
LED Name  
Function  
Visible fault warning  
Location  
LED Color  
Green or Amber Green = No Fault  
Green blinking = degraded  
Notes  
System Fault  
Control panel  
and board rear  
left corner  
condition  
Amber blinking = non-  
critical error  
Amber = critical or non-  
recoverable error  
Drive Activity  
BIOS POST Beep Codes  
The table below lists the POST error beep codes. Prior to system video initialization, the  
BIOS uses these beep codes to inform users of error conditions. Please note that not all  
error conditions are supported by BIOS beep codes.  
Table 6. POST Error Beep Codes  
Number of Beeps  
Reason for Beeps and Action to Take  
1, 2, or 3  
Memory error. Reseat the memory or replace the DIMMs with known good modules.  
4 - 7 or 9 - 11  
Fatal error indicating a possible serious system problem. Remove all add-in cards and  
re-start the system. If the error still occurs, contact your system manufacturer. If the  
beep codes are not generated after the add-in cards are removed, insert the cards one  
at a time, booting the system between each card addition, until the beeps again occur  
to reveal the malfunctioning card.  
8
Replace or reseat the system video add-in card. If on-board video is bing used, the  
server board may be faulty.  
®
®
32  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Getting Help  
World Wide Web  
http://support.intel.com/support/motherboards/server/SE7230NH1-E.  
Telephone  
All calls are billed per incident, levied in local currency at the applicable credit card  
exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for  
telephone support at any time without notice).  
Before calling, fill out an “Intel® Server Issue Report Form”. A sample form is provided  
on the following pages. However, for the fastest service, please submit your form via the  
Internet.  
U.S. and Canada  
1-800-404-2284  
Europe  
UK.............. 870 6072439  
France......... 01 41 918529  
Germany..... 069 9509 6099  
Italy ............ 02 696 33276  
Spain........... 91 377 8166  
Belgium...... 02 714 3182  
Finland ....... 9 693 79297  
Denmark..... 38 487077  
Norway....... 23 1620 50  
Sweden....... 08 445 1251  
Holland....... 020 487 4562  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In Asia-Pacific region  
Australia..... 1800 649931  
Hong Kong. 852 2 844 4456  
Korea.......... 822 767 2595  
China.......... 800 820 1100 (toll-free)  
.................... 8 621 33104691 (not toll-free)  
Singapore ... 65 6213-1311  
India ........... 0006517 2 68303634 (manual toll-free. You need an IDD-equipped  
telephone)  
Taiwan........ 2 2545-1640  
Indonesia.... 803 65 7249  
Malaysia..... 1 800 80 1390  
New Zealand 0800 444 365  
Pakistan...... 632 63684 15 (IDD via Philippines)  
Philippines.. 1 800 1 651 0117  
Thailand ..... 1 800 631 0003  
Vietnam ...... 632 6368416 (IDD via Philippines)  
Myanmar.... 63 2 636 9796 (via Philippines)  
Cambodia ... 63 2 636 9797 (via Philippines)  
Japan  
Domestic .... 0120 868686  
Outside country  
81 298 47 0800  
Latin America  
Brazil.......... 001-916 377 0180  
Mexico ....... Contact AT&T USA at 001 800 462 628 4240. Once connected, dial 800 843  
4481  
Colombia.... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481  
Costa Rica .. Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481  
Panama....... Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481  
®
®
34  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chile (Easter Island) ........... Contact AT&T USA at 800 800 311. Once connected, dial  
800 843 4481  
Chile (Mainland and Juan)Contact AT&T USA at 800 225 288. Once connected, dial 800  
843 4481  
Miami......... 1 800 621 8423  
Ecuador (Andimate)............ Contact AT&T USA at 1 999 119. Once connected, dial 800  
843 4481  
Ecuador (Pacifictel). ............ Contact AT&T USA at 1 800 225 528. Once connected, dial  
800 843 4481  
Guatemala .. Contact AT&T USA at 99 99 190. Once connected, dial 800 843 4481  
Venezuela ... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481  
Argentina.... Contact AT&T USA at 0-800 222 1288. Once connected, dial 800 843 4481  
Paraguay..... 001 916 377 0114  
Peru ............ 001 916 377 0114  
Uruguay...... 001 916 377 0114  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
®
36  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B Safety Information  
English  
Server Safety Information  
This document applies to Intel® server boards, Intel® server chassis (pedestal and rack-  
mount) and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire,  
and equipment damage, read this document and observe all warnings and precautions in  
this guide before installing or maintaining your Intel® server product.  
In the event of a conflict between the information in this document and information  
provided with the product or on the website for a particular product, the product  
documentation takes precedence.  
Your server should be integrated and serviced only by technically qualified persons.  
You must adhere to the guidelines in this guide and the assembly instructions in your  
server manuals to ensure and maintain compliance with existing product certifications and  
approvals. Use only the described, regulated components specified in this guide. Use of  
other products / components will void the UL Listing and other regulatory approvals of  
the product, and may result in noncompliance with product regulations in the region(s) in  
which the product is sold.  
Safety Warnings and Cautions  
To avoid personal injury or property damage, before you begin installing the product,  
read, observe, and adhere to all of the following safety instructions and information. The  
following safety symbols may be used throughout the documentation and may be marked  
on the product and / or the product packaging.  
Indicates the presence of a hazard that may cause minor personal injury or  
property damage if the CAUTION is ignored.  
Indicates the presence of a hazard that may result in serious personal injury  
if the WARNING is ignored.  
Indicates potential hazard if indicated information is ignored.  
CAUTION  
WARNING  
Indicates shock hazards that result in serious injury or death if safety  
instructions are not followed.  
Indicates hot components or surfaces.  
Indicates do not touch fan blades, may result in injury.  
Indicates to unplug all AC power cord(s) to disconnect AC power  
Please recycle battery  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intended Application Uses  
This product was evaluated as Information Technology Equipment (ITE), which may be  
installed in offices, schools, computer rooms, and similar commercial type locations. The  
suitability of this product for other product categories and environments (such as medical,  
industrial, residential, alarm systems, and test equipment), other than an ITE application,  
may require further evaluation.  
Site Selection  
The system is designed to operate in a typical office environment. Choose a site that is:  
Clean, dry, and free of airborne particles (other than normal room dust).  
Well-ventilated and away from sources of heat including direct sunlight and radiators.  
Away from sources of vibration or physical shock.  
Isolated from strong electromagnetic fields produced by electrical devices.  
In regions that are susceptible to electrical storms, we recommend you plug your  
system into a surge suppresser and disconnect telecommunication lines to your  
modem during an electrical storm.  
Provided with a properly grounded wall outlet.  
Provided with sufficient space to access the power supply cord(s), because they serve  
as the product's main power disconnect.  
Equipment Handling Practices  
Reduce the risk of personal injury or equipment damage:  
Conform to local occupational health and safety requirements when moving and  
lifting equipment.  
Use mechanical assistance or other suitable assistance when moving and lifting  
equipment.  
To reduce the weight for easier handling, remove any easily detachable components.  
Power and Electrical Warnings  
Caution: The power button, indicated by the stand-by power marking, DOES NOT completely turn  
off the system AC power, 5V standby power is active whenever the system is plugged in.  
To remove power from system, you must unplug the AC power cord from the wall outlet.  
Your system may use more than one AC power cord. Make sure all AC power cords are  
®
®
38  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
unplugged. Make sure the AC power cord(s) is/are unplugged before you open the  
chassis, or add or remove any non hot-plug components.  
Do not attempt to modify or use an AC power cord if it is not the exact type required. A  
separate AC cord is required for each system power supply.  
Some power supplies in Intel® servers use Neutral Pole Fusing. To avoid risk of shock use  
caution when working with power supplies that use Neutral Pole Fusing.  
The power supply in this product contains no user-serviceable parts. Do not open the  
power supply. Hazardous voltage, current and energy levels are present inside the power  
supply. Return to manufacturer for servicing.  
When replacing a hot-plug power supply, unplug the power cord to the power supply  
being replaced before removing it from the server.  
To avoid risk of electric shock, turn off the server and disconnect the power cord,  
telecommunications systems, networks, and modems attached to the server before opening  
it.  
Power Cord Warnings  
If an AC power cord was not provided with your product, purchase one that is approved  
for use in your country.  
Caution: To avoid electrical shock or fire, check the power cord(s) that will be used with the  
product as follows:  
Do not attempt to modify or use the AC power cord(s) if they are not the exact type  
required to fit into the grounded electrical outlets  
The power cord(s) must meet the following criteria:  
The power cord must have an electrical rating that is greater than that of the  
electrical current rating marked on the product.  
The power cord must have safety ground pin or contact that is suitable for the  
electrical outlet.  
The power supply cord(s) is/are the main disconnect device to AC power. The socket  
outlet(s) must be near the equipment and readily accessible for disconnection.  
The power supply cord(s) must be plugged into socket-outlet(s) that is /are provided  
with a suitable earth ground.  
System Access Warnings  
Caution: To avoid personal injury or property damage, the following safety instructions apply  
whenever accessing the inside of the product:  
Turn off all peripheral devices connected to this product.  
Turn off the system by pressing the power button to off.  
Disconnect the AC power by unplugging all AC power cords from the system or wall  
outlet.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disconnect all cables and telecommunication lines that are connected to the system.  
Retain all screws or other fasteners when removing access cover(s). Upon  
completion of accessing inside the product, refasten access cover with original screws  
or fasteners.  
Do not access the inside of the power supply. There are no serviceable parts in the  
power supply. Return to manufacturer for servicing.  
Power down the server and disconnect all power cords before adding or replacing  
any non hot-plug component.  
When replacing a hot-plug power supply, unplug the power cord to the power supply  
being replaced before removing the power supply from the server.  
Caution: If the server has been running, any installed processor(s) and heat  
sink(s) may be hot. Unless you are adding or removing a hot-plug  
component, allow the system to cool before opening the covers. To avoid  
the possibility of coming into contact with hot component(s) during a hot-  
plug installation, be careful when removing or installing the hot-plug  
component(s).  
Caution: To avoid injury do not contact moving fan blades. If your system is supplied with a guard  
over the fan, do not operate the system without the fan guard in place.  
Rack Mount Warnings  
The equipment rack must be anchored to an unmovable support to prevent it from tipping  
when a server or piece of equipment is extended from it. The equipment rack must be  
installed according to the rack manufacturer's instructions.  
Install equipment in the rack from the bottom up, with the heaviest equipment at the  
bottom of the rack.  
Extend only one piece of equipment from the rack at a time.  
You are responsible for installing a main power disconnect for the entire rack unit. This  
main disconnect must be readily accessible, and it must be labeled as controlling power to  
the entire unit, not just to the server(s).  
To avoid risk of potential electric shock, a proper safety ground must be implemented for  
the rack and each piece of equipment installed in it.  
Electrostatic Discharge (ESD)  
Caution: ESD can damage disk drives, boards, and other parts. We recommend that you perform  
all procedures at an ESD workstation. If one is not available, provide some ESD  
protection by wearing an antistatic wrist strap attached to chassis ground -- any  
unpainted metal surface -- on your server when handling parts.  
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards  
only by their edges. After removing a board from its protective wrapper or from the  
®
®
40  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
server, place the board component side up on a grounded, static free surface. Use a  
conductive foam pad if available but not the board wrapper. Do not slide board over any  
surface.  
Other Hazards  
Battery Replacement  
Caution: There is the danger of explosion if the battery is incorrectly replaced.  
When replacing the battery, use only the battery recommended by the  
equipment manufacturer.  
Dispose of batteries according to local ordinances and regulations.  
Do not attempt to recharge a battery.  
Do not attempt to disassemble, puncture, or otherwise damage a battery.  
Cooling and Airflow  
Caution: Carefully route cables as directed to minimize airflow blockage and cooling problems.  
For proper cooling and airflow, operate the system only with the chassis covers installed.  
Operating the system without the covers in place can damage system parts. To install the  
covers:  
Check first to make sure you have not left loose tools or parts inside the system.  
Check that cables, add-in boards, and other components are properly installed.  
Attach the covers to the chassis according to the product instructions.  
Laser Peripherals or Devices  
Caution: To avoid risk of radiation exposure and/or personal injury:  
Do not open the enclosure of any laser peripheral or device  
Laser peripherals or devices have are not user serviceable  
Return to manufacturer for servicing  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Deutsch  
Sicherheitshinweise für den Server  
Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse  
(Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und  
Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag,  
Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig,  
bevor Sie Ihr Intel® Serverprodukt installieren oder warten.  
Bei Widersprüchen zwischen den hier vorliegenden Angaben und den Informationen im  
Lieferumfang des Produkts oder auf der Website des betreffenden Produkts hat die  
Produktdokumentation Vorrang.  
Die Integration und Wartung des Servers darf nur durch technisch qualifizierte Personen  
erfolgen.  
Um die Einhaltung der vorhandenen Zulassungen und Genehmigungen für das Produkt zu  
gewährleisten, sind die Richtlinien in diesem Handbuch sowie die Montageanleitungen in  
den Serverhandbüchern zu beachten. Verwenden Sie nur die beschriebenen, zugelassenen  
Komponenten, die im vorliegenden Handbuch angegeben werden. Die Verwendung  
anderer Produkte oder Komponenten führt zum Erlöschen der UL-Zulassung und anderer  
Genehmigungen für das Produkt. Dadurch kann das Produkt gegen Produktbestimmungen  
verstoßen, die im Verkaufsland gelten.  
Sicherheitshinweise und Vorsichtsmaßnahmen  
Um Verletzungen und Beschädigungen zu vermeiden, sollten Sie vor dem Beginn der  
Produktinstallation die nachfolgend aufgeführten Sicherheitshinweise und -informationen  
sorgfältig lesen und befolgen. In dem vorliegenden Handbuch sowie auf dem Produkt und  
auf der Verpackung werden folgende Sicherheitssymbole verwendet:  
Weist auf eine Gefahrenquelle hin, die bei Nichtbeachtung des  
VORSICHT  
WARNUNG  
VORSICHTSHINWEISES zu leichteren Verletzungen bzw.  
Sachbeschädigungen führen kann.  
Weist auf eine Gefahrenquelle hin, die bei Nichtbeachtung der WARNUNG zu  
ernsten Verletzungen führen kann.  
Weist auf potentielle Gefahr bei Nichtbeachtung der angezeigten Informationen  
hin.  
Weist auf die Gefahr eines Stromschlags hin, der bei Nichtbeachtung der  
Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann.  
Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin.  
Weist darauf hin, daß das Anfassen des Gebläses zu Verletzungen führen kann.  
Bedeutet, alle Netzkabel abzuziehen und das Gerät von der Netzspannung zu  
trennen.  
Bereiten Sie bitte Batterie auf  
®
®
42  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Zielbenutzer der Anwendung  
Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen,  
Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die  
Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B. Medizin, Industrie,  
Alarmsysteme oder Prüfgeräte) kann u. U. weitere Tests erfordern.  
Standortauswahl  
Das System ist für den Betrieb innerhalb normaler Büroumgebungen geeignet. Wählen  
Sie einen Standort, der folgenden Kriterien entspricht:  
Sauber, trocken und frei von Partikeln in der Luft (außer dem normalen Raumstaub).  
Gut belüftet, nicht in der Nähe von Wärmequellen und keiner direkten  
Sonnenbestrahlung ausgesetzt.  
Nicht in der Nähe von Vibrations- oder Erschütterungsquellen.  
Abgeschirmt von starken elektromagnetischen Feldern, die durch elektrische Geräte  
erzeugt werden.  
In gewittergefährdeten Gebieten sollten Sie das System an einen  
Überspannungsschutz anschließen und bei einem Gewitter die  
Telekommunikationskabel zum Modem abziehen.  
Eine ordnungsgemäß geerdete Wandsteckdose muß vorhanden sein.  
Ausreichender Freiraum für den Zugang zu den Netzkabeln, da diese die  
Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind.  
Handhabung von Geräten  
Beachten Sie zur Vermeidung von Verletzungen oder Beschädigungen an den Geräten die  
folgenden Hinweise:  
Halten Sie beim Transportieren und Anheben von Geräten die örtlichen Gesundheits-  
und Sicherheitsvorschriften ein.  
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren  
oder Anheben von Geräten.  
Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu  
reduzieren und die Handhabung zu erleichtern.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnungen zu Netzspannung und Elektrizität  
Vorsicht: Durch Betätigen der mit dem Standby-Symbol gekennzeichneten Netztaste wird das  
System NICHT vollständig vom Netz getrennt. Es sind weiterhin 5 V aktiv, solange das  
System eingesteckt ist. Um das System vollständig vom Strom zu trennen, muß das  
Netzkabel aus der Steckdose abgezogen werden. Das System verfügt möglicherweise über  
mehrere Netzkabel. Vergewissern Sie sich in diesem Fall, daß alle Netzkabel abgezogen  
sind. Wenn Sie Komponenten ein- oder ausbauen möchten, die nicht hot-plug-fähig sind,  
stellen Sie sicher, daß zuvor alle Netzkabel abgezogen sind.  
Nehmen Sie keine Änderungen am Netzkabel vor, und verwenden Sie kein Kabel, das nicht  
genau dem geforderten Typ entspricht. Jedes Netzteil im System muß über ein eigenes  
Netzkabel angeschlossen werden.  
Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten  
im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines  
elektrischen Schlages zu vermeiden  
Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden  
können. Öffnen Sie das Netzteil nicht. Im Netzteil bestehen gefährliche Spannungen,  
Ströme und Energiequellen. Schicken Sie das Gerät für Wartungsarbeiten an den  
Hersteller zurück.  
Wenn Sie ein hot-plug-fähiges Netzteil austauschen, ziehen Sie dessen Netzkabel ab, bevor  
Sie es aus dem Server ausbauen.  
Zur Vermeidung von Stromschlägen schalten Sie den Server aus, und trennen Sie vor dem  
Öffnen des Geräts das Netzkabel sowie alle an den Server angeschlossene  
Telekommunikationssysteme, Netzwerke und Modems.  
Hinweis für Netzkabel  
Wenn kein Netzkabel mit dem Produkt geliefert wurde, kaufen Sie ein Kabel, das für die  
Vorsicht: Prüfen Sie zur Vermeidung von Stromschlag- oder Feuergefahr die mit dem Produkt zu  
verwendenden Netzkabel wie folgt:  
Nehmen Sie keine Änderungen an einem Netzkabel vor, und benutzen sie es nicht,  
wenn es nicht genau in die geerdeten Netzsteckdosen paßt.  
Netzkabel müssen die folgenden Anforderungen erfüllen:  
Die Nennbelastbarkeit des Netzkabels muß mindestens so hoch sein wie die am  
Produkt angegebenen Nennstromaufnahme.  
Das Netzkabel muß einen zur Netzsteckdose passenden Schutzkontakt besitzen.  
Die Netzkabel sind die Hauptvorrichtung zum Trennen des Geräts vom Stromnetz.  
Die Steckdose muß in der Nähe der Anlage angebracht und gut erreichbar sein.  
Netzkabel müssen an eine ordnungsgemäß geerdete Steckdose angeschlossen sein.  
®
®
44  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnhinweise für den Systemzugang  
Vorsicht: Um Verletzungen und Beschädigungen zu vermeiden, sollten Sie vor Arbeiten im  
Produktinneren folgende Sicherheitsanweisungen beachten:  
Schalten Sie alle am Produkt angeschlossenen Peripheriegeräte aus.  
Schalten Sie das System mit dem Netzschalter aus.  
Trennen Sie das Gerät von der Stromquelle, indem Sie alle Netzkabel vom System bzw.  
aus der Steckdose ziehen.  
Ziehen Sie alle Kabel und alle an das System angeschlossenen  
Telekommunikationsleitungen ab.  
Bewahren Sie alle Schrauben und anderen Befestigungselemente gut auf, nachdem Sie  
die Gehäuseabdeckung entfernt haben. Wenn Sie Ihre Arbeiten im Systeminneren  
beendet haben, befestigen Sie die Gehäuseabdeckung mit den Originalschrauben bzw.  
-befestigungselementen.  
Führen Sie keine Arbeiten im Netzteil aus. Das Netzteil enthält keine für den Benutzer  
wartungsbedürftigen Teile. Schicken Sie das Gerät für Wartungsarbeiten an den  
Hersteller zurück.  
Schalten Sie den Server aus, und ziehen Sie alle Netzkabel ab, bevor Sie Komponenten  
ein- oder ausbauen, die nicht hot-plug-fähig sind.  
Wenn Sie ein hot-plug-fähiges Netzteil austauschen, ziehen Sie dessen Netzkabel ab,  
bevor Sie es aus dem Server ausbauen.  
Vorsicht: War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein.  
Sofern Sie keine Hot-Plug-Komponenten ein- oder ausbauen, warten Sie mit dem  
Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder  
Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten  
in Berührung zu kommen.  
Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr  
System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben  
werden.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnhinweise für Racks  
Das Geräte-Rack muß auf einer geeigneten, festen Unterlage verankert werden, um ein  
Umkippen zu vermeiden, wenn ein Server oder andere Geräte herausgezogen werden.  
Bei der Installation des Racks müssen die Anweisungen des Rack-Herstellers beachtet  
werden.  
Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und  
bauen Sie das schwerste Gerät an der untersten Position im Rack ein.  
Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus.  
Sie müssen für die gesamte Rack-Einheit einen Netztrennschalter einrichten. Dieser  
Netztrennschalter muß leicht zugänglich sein und über eine Kennzeichnung verfügen, die  
besagt, daß er die Stromzufuhr zur gesamten Einheit steuert und nicht nur zu den Servern.  
Zur Vermeidung von Stromschlaggefahr müssen das Rack selbst und alle darin  
eingebauten Geräte ordnungsgemäß geerdet sein.  
Elektrostatische Entladungen (ESD)  
Vorsicht: Elektrostatische Entladungen können zur Beschädigung von Festplatten, Platinen und  
anderen Komponenten führen. Daher sollten Sie alle Arbeiten an einer ESD-Workstation  
ausführen. Steht ein solcher Arbeitsplatz nicht zur Verfügung, erzielen Sie einen gewissen  
Schutz vor elektrostatischen Entladungen durch Tragen einer Antistatik-Manschette, die  
Sie während der Arbeit zur Erdung an einem beliebigen unlackierten Metallteil des  
Computergehäuses befestigen.  
Gehen Sei bei der Handhabung von Platinen immer mit größter Vorsicht vor. Sie können  
äußerst empfindlich gegenüber elektrostatischer Entladung sein. Halten Sie Platinen nur  
an den Kanten fest. Legen Sie die Platinen nach dem Auspacken aus der Schutzhülle oder  
nach dem Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete,  
statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige  
Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine  
nicht über eine Fläche.  
®
®
46  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Andere Gefahren  
Batterieaustausch  
Vorsicht: Wird die Batterie unsachgemäß ausgetauscht, besteht Explosionsgefahr. Verwenden Sie  
als Ersatz nur die vom Gerätehersteller empfohlene Batterie.  
Beachten Sie bei der Entsorgung von Batterien die gültigen Bestimmungen.  
Versuchen Sie nicht, eine Batterie aufzuladen.  
Versuchen Sie nicht, eine Batterie zu öffnen oder sonstwie zu beschädigen.  
Kühlung und Luftstrom  
Vorsicht: Verlegen Sie Kabel sorgfältig entsprechend der Anleitung, um Störungen des Luftstroms  
und Kühlungsprobleme zu vermeiden.  
Zur Gewährleistung des ordnungsgemäßen Kühlungs- und Luftstromverhaltens darf das  
System nur mit angebrachten Gehäuseabdeckungen betrieben werden. Die  
Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von  
Systemkomponenten führen. So bringen Sie die Abdeckung wieder an:  
Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse  
vergessen haben.  
Prüfen Sie, ob Kabel, Erweiterungskarten sowie weitere Komponenten  
ordnungsgemäß angebracht sind.  
Befestigen Sie die Abdeckungen am Gehäuse des Produkts, wie in dessen Anleitung  
beschrieben.  
Laser-Peripheriegeräte oder -Komponenten  
Vorsicht: Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise:  
Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser-  
Komponenten.  
Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer  
wartungsbedürftigen Teile.  
Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Français  
Consignes de sécurité sur le serveur  
Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds  
et sur rack) et aux périphériques installés. Pour réduire les risques de dommages  
corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et  
respectez tous les avertissements et précautions mentionnés dans ce guide avant  
d’installer ou de mettre à jour votre produit serveur Intel®.  
En cas de conflit entre les informations fournies dans ce document et celles livrées avec le  
produit ou publiées sur le site Web pour un produit particulier, la documentation du  
produit prime.  
Votre serveur doit être intégré et entretenu uniquement par des techniciens qualifiés.  
Vous devez suivre les informations de ce guide et les instructions d’assemblage des  
manuels de serveur pour vérifier et maintenir la conformité avec les certifications et  
approbations de produit existantes. Utilisez uniquement les composants décrits et  
réglementés spécifiés dans ce guide. L’utilisation d’autres produits/composants annulera  
la liste UL et les autres approbations réglementaires du produit, et le produit peut ne pas  
être conforme aux autres lois et réglementations locales applicables au produit.  
Sécurité: avertissements et mises en garde  
Pour éviter de vous blesser ou d’endommager votre équipement, lisez et respectez toutes  
les informations et consignes de sécurité avant de commencer l’installation du produit.  
Les symboles de sécurité suivants peuvent être utilisés tout au long de cette  
documentation et peuvent figurer sur le produit ou sur son emballage.  
Indique la présence d’un risque pouvant entraîner des blessures physiques  
ATTENTION  
mineures ou endommager légèrement le matériel si la mise en garde n’est pas  
prise en compte.  
Indique la présence d’un risque pouvant entraîner des blessures corporelles  
graves si l’avertissement n’est pas pris en compte.  
AVERTISSEMENT  
Indique un risque potentiel si les informations signalées ne sont pas prises en  
compte.  
Indique des risques d’électrocution pouvant entraîner des blessures  
corporelles graves ou mortelles si les consignes de sécurité ne sont pas  
respectées.  
Signale des composants ou des surfaces soumis à des températures élevées.  
Indique de ne pas toucher aux pales de ventilateur, car cela peut entraîner des  
blessures.  
Indique de débrancher tous les cordons d’alimentation secteur pour  
déconnecter l’alimentation.  
Veuillez réutiliser la batterie  
®
®
48  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Domaines d’utilisation prévus  
Ce produit a été testé comme équipement informatique (ITE) et peut être installé dans des  
bureaux, des écoles, des salles informatiques et des endroits commerciaux similaires.  
L’utilisation du présent produit dans des catégories et environnements de produits et  
domaines d’application (par exemple, le domaine médical, industriel, résidentiel, les  
systèmes d’alarme et les appareils de contrôle) autres qu’ITE doit faire l’objet  
d’évaluations supplémentaires.  
Sélection d’un emplacement  
Le système est conçu pour fonctionner dans un environnement standard de bureau.  
Choisissez un emplacement respectant les conditions suivantes :  
Propre, sec et exempt de particules en suspension (autres que la poussière normale  
d’une pièce).  
Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et  
les radiateurs.  
À l’écart des sources de vibration ou des chocs physiques.  
Isolé des champs électromagnétiques importants produits par des appareils  
électriques.  
Dans les régions sujettes aux orages magnétiques, nous vous recommandons de  
brancher votre système à un suppresseur de surtension et de déconnecter les lignes de  
télécommunication de votre modem pendant les orages.  
Équipé d’une prise murale reliée à la terre.  
Équipé d’un espace suffisant pour accéder aux cordons d’alimentation secteur, car ils  
servent de disjoncteur principal d’alimentation du produit.  
Pratiques de manipulation de l’équipement  
Réduisez le risque de dommages personnels ou matériels :  
Conformez-vous aux exigences de médecine du travail et de sécurité lorsque vous  
déplacez et soulevez le matériel.  
Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous  
déplacez et soulevez le matériel.  
Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant  
amovible.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alimentation et avertissements en matière d’électricité  
Attention: Le bouton d’alimentation, indiqué par le symbole de mise en veille, NE COUPE PAS  
complètement l’alimentation secteur du système car le courant de veille 5 V reste actif  
lorsque le système est sous tension. Pour couper l’alimentation du système, vous devez  
débrancher le cordon d’alimentation secteur de la prise murale. Votre système peut  
utiliser plusieurs cordons d’alimentation secteur. Assurez-vous que tous les cordons  
d’alimentation sont débranchés. Vous devez les débrancher avant d’ouvrir le châssis,  
d’ajouter ou de supprimer un composant non connectable à chaud.  
Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre:  
veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.  
N’essayez pas de modifier ou d’utiliser un cordon d’alimentation secteur s’il ne s’agit pas  
du type exact requis. Un cordon secteur est requis pour chaque alimentation système.  
Le bloc d’alimentation de ce produit ne contient aucun composant réparable par  
l’utilisateur. N’ouvrez pas le bloc d’alimentation. L’intérieur de celui-ci est soumis à des  
niveaux dangereux de tension, de courant et d’énergie. Renvoyez-le au fabricant en cas de  
problème.  
Lorsque vous remplacez un bloc d’alimentation à chaud, débranchez le cordon du bloc  
d’alimentation en cours de remplacement avant de le retirer du serveur.  
Pour éviter tout risque d’électrocution, mettez le système hors tension et débranchez les  
cordons d’alimentation ainsi que les systèmes de télécommunication, réseaux et modems  
reliés au système avant d’ouvrir ce dernier.  
Avertissements sur le cordon d’alimentation  
Si aucun cordon d’alimentation secteur n’a été fourni avec votre produit, vous devez vous  
en procurer un qui soit approuvé pour une utilisation dans votre pays.  
Attention: Pour éviter tout risque d’électrocution ou d’incendie, vérifiez les cordons d’alimentation  
qui seront utilisés avec le produit comme suit:  
N’essayez pas d’utiliser ou de modifier les cordons d’alimentation en CA s’ils ne  
correspondent pas exactement au type requis pour les prises électriques reliées à la  
terre.  
Les cordons d’alimentation doivent répondre aux critères suivants :  
Le cordon d’alimentation doit supporter une intensité supérieure à celle indiquée sur  
le produit.  
Le cordon d’alimentation doit posséder une broche ou un contact de mise à la terre  
approprié à la prise électrique.  
Les cordons d’alimentation électrique représentent le principal dispositif de  
déconnexion raccordé à l’alimentation secteur. Les prises de courant doivent se  
trouver à proximité de l’équipement et être facilement accessibles pour une  
déconnexion.  
Les cordons d’alimentation doivent être branchés sur des prises électriques  
correctement reliées à la terre.  
®
®
50  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Avertissements sur l’accès au système  
Attention: Pour éviter de vous blesser ou d’endommager votre équipement, les consignes de sécurité  
suivantes s’appliquent chaque fois que vous accédez à l’intérieur du produit:  
Mettez hors tension tous les périphériques connectés à ce produit.  
Éteignez le système en appuyant sur le bouton d’alimentation.  
Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation  
secteur du système ou de la prise murale.  
Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés  
au système.  
Mettez toutes les vis ou autres attaches de côté lorsque vous retirez les panneaux  
d’accès. Une fois que vous avez terminé d’accéder à l’intérieur du produit, refixez le  
panneau d’accès avec les vis ou attaches d’origine.  
N’essayez pas d’accéder à l’intérieur du bloc d’alimentation. Il ne contient aucune  
pièce réparable. Renvoyez-le au fabricant en cas de problème.  
Mettez le serveur hors tension et débranchez tous les cordons d’alimentation avant  
d’ajouter ou de remplacer tout composant non connectable à chaud.  
Lorsque vous remplacez le bloc d’alimentation à chaud, débranchez le cordon du bloc  
d’alimentation en cours de remplacement avant de retirer le bloc du serveur.  
Attention: Si le serveur a été utilisé, les processeurs et dissipateurs de chaleur installés peuvent être  
chauds. À moins que vous n’ajoutiez ou ne retiriez un composant connectable à chaud,  
laissez le système refroidir avant d’ouvrir les panneaux. Pour éviter tout risque d’entrer  
en contact avec un composant chaud lors d’une installation à chaud, prenez toutes les  
précautions nécessaires lorsque vous retirez ou installez des composants connectables à  
chaud.  
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre  
système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route  
sans la protection en place.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Avertissements sur le montage en rack  
Le rack doit être fixé à un support inamovible pour éviter qu’il ne bascule lors de  
l’extension d’un serveur ou d’un élément de l’équipement. Le rack doit être installé  
conformément aux instructions du fabricant.  
Installez les équipements dans le rack en partant du bas, en plaçant le plus lourd en bas du  
rack.  
N’étendez qu’un seul élément de l’équipement à partir du rack à la fois.  
Vous êtes responsable de l’installation d’un disjoncteur principal d’alimentation pour la  
totalité du rack. Ce disjoncteur principal doit être rapidement accessible et doit être  
étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs.  
Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé  
dans le rack doivent être correctement reliés à la terre.  
Décharges électrostatiques†(ESD)  
Attention: Les décharges électrostatiques (ESD) peuvent endommager les lecteurs de disque dur, les  
cartes et d’autres pièces. Il est fortement conseillé d’effectuer l’ensemble des procédures  
décrites à un poste de travail protégé contre les ESD. Au cas où aucun poste de ce type ne  
serait disponible, protégez-vous contre les ESD en portant un bracelet antistatique relié à  
la masse du châssis (n’importe quelle surface métallique non peinte) de votre serveur  
lorsque que vous manipulez les pièces.  
Manipulez toujours les cartes avec précaution. Elles peuvent être extrêmement sensibles  
aux ESD. Ne tenez les cartes que par leurs bords. Après avoir retiré une carte de son  
emballage de protection ou du serveur, placez-la sur une surface reliée à la terre, exempte  
de charge statique, composants orientés vers le haut. Utilisez si possible un tapi de  
mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse  
sur aucune surface.  
®
®
52  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Autres risques  
Remplacement de la pile  
Attention: Il existe un risque d’explosion si la pile n’est pas correctement remplacée. Lors du  
remplacement de la pile, utilisez uniquement celle recommandée par le fabricant du  
matériel.  
Mettez la pile au rebut en vous conformant aux réglementations locales.  
N’essayez pas de recharger une pile.  
N’essayez pas de démonter, de percer ou d’endommager la pile d’une quelconque façon.  
Refroidissement et ventilation  
Attention: Routez les câbles avec précaution comme indiqué pour minimiser les blocages de  
circulation d’air et les problèmes de refroidissement.  
Afin de permettre une ventilation et un refroidissement corrects, ne mettez le système en  
marche que lorsque les panneaux du châssis sont en place. Lutilisation du système sans  
les panneaux peut endommager les composants système. Pour installer les panneaux :  
Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à  
l’intérieur du système.  
Vérifiez que les câbles, les cartes d’extension et les autres composants sont  
correctement installés.  
Fixez les panneaux au châssis en suivant les instructions du produit.  
Périphériques laser  
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel:  
N’ouvrez pas l’enceinte d’un périphérique laser.  
Les périphériques laser ne sont pas réparables par l’utilisateur.  
Retournez-les au fabricant en cas de problème.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Español  
Información de seguridad del servidor  
Este documento se aplica a las tarjetas de servidor de Intel®, las carcasas de servidor de  
Intel® (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el  
riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento  
y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o  
mantener el producto de servidor de Intel®.  
En el caso de que haya diferencias entre la información para un producto en particular  
contenida en este documento y la información proporcionada con dicho producto o en el  
sitio Web, la documentación del producto es la que prevalece.  
Sólo personal técnico cualificado debe montar y prestar los servicios para el servidor.  
Debe ceñirse a las directrices de esta guía y a las instrucciones de montaje de los manuales  
del servidor para asegurar y mantener el cumplimiento con las certificaciones y  
homologaciones existentes de los productos. Utilice sólo los componentes descritos y  
homologados que se especifican en esta guía. El uso de otros productos o componentes  
anulará la homologación UL y otras certificaciones oficiales del producto, pudiendo dejar  
de ser compatible con las normativas locales de los países en los que se comercializa.  
Advertencias y precauciones sobre seguridad  
Para reducir la posibilidad de que se produzcan lesiones personales o daños en la  
propiedad, antes de empezar a instalar el producto, lea, observe y cumpla toda la  
información e instrucciones de seguridad siguientes. Puede que se utilicen los siguientes  
símbolos de seguridad en la documentación y es posible que aparezcan en el producto o en  
su embalaje.  
Indica la existencia de un riesgo que podría causar lesiones personales o daños  
PRECAUCIÓN  
en la propiedad leves si no se tiene en cuenta la PRECAUCIÓN.  
Indica la existencia de un riesgo que podría causar lesiones personales graves  
si no se tiene en cuenta la ADVERTENCIA.  
ADVERTENCIA  
Indica un riesgo potencial si no se tiene en cuenta la información indicada.  
Indica riesgo de descargas eléctricas que podrían causar lesiones graves o la  
muerte si no se siguen las instrucciones de seguridad.  
Indica componentes o superficies calientes.  
Indica que no se deben tocar las aspas de los ventiladores, ya que de lo  
contrario se podrían producir lesiones.  
Indica que es necesario desenchufar los cables de alimentación de CA para  
desconectar la alimentación de CA  
Recicle por favor la batería  
®
®
54  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Aplicaciones y usos previstos  
Este producto ha sido evaluado como equipo de tecnología informática (ITE) que puede  
instalarse en oficinas, escuelas, salas de equipos informáticos o lugares de ámbito  
comercial similares. Es posible que sea necesario llevar a cabo una evaluación adicional  
para comprobar si este producto es apropiado para otras categorías de productos y  
entornos además de las aplicaciones informáticas (por ejemplo, soluciones médicas,  
industriales, residenciales, sistemas de alarma y equipos de pruebas).  
Selección de la ubicación  
El sistema se ha diseñado para funcionar en un entorno normal de oficinas. Seleccione una  
ubicación que esté:  
Limpia, seca y libre de macropartículas en suspensión en el aire (que no sean el polvo  
habitual de la habitación).  
Bien ventilada y alejada de fuentes de calor, incluida la luz solar directa y los  
radiadores.  
Alejada de fuentes de vibración o de golpes físicos.  
Aislada de campos electromagnéticos producidos por dispositivos eléctricos.  
En zonas propensas a tormentas eléctricas, se recomienda que conecte el servidor a un  
supresor de sobretensiones y desconecte las líneas de telecomunicaciones al módem  
durante una tormenta eléctrica.  
Provista de una toma de corriente alterna correctamente conectada a tierra.  
Provista de espacio suficiente para acceder a los cables de la fuente de alimentación  
ya que constituyen la desconexión principal de la alimentación.  
Manipulación del equipo  
Reduzca el riesgo de daños personales o en el equipo:  
Respete los requisitos de sanidad y seguridad laborales de su país cuando traslade y  
levante el equipo.  
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo.  
Para que el peso sea menor para manipularlo con más facilidad, extraiga los  
componentes que sean de fácil extracción.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advertencias de alimentación y eléctricas  
Precaución: El botón de encendido, indicado con la marca del modo de reposo o stand-by, NO  
DESCONECTA completamente la alimentación de CA del sistema, ya que el modo de  
reposo de 5 V sigue activo mientras el sistema está enchufado. Para desconectar el  
sistema debe desenchufar el cable de alimentación de CA de la toma de la pared. Puede  
usar más de un cable de alimentación de CA con el sistema. Asegúrese de que todos los  
cables de alimentación de CA están desenchufados. Asegúrese de que los cables de  
alimentación de CA estén desenchufado antes de abrir la carcasa, agregar o extraer  
cualquier componente que no es de conexión en funcionamiento.  
Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo  
neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al  
trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.  
No intente modificar ni utilizar un cable de alimentación de CA si no es del tipo exacto  
requerido. Se necesita un cable de CA para cada fuente de alimentación del sistema.  
La fuente de alimentación de este producto no contiene piezas que puedan ser reparadas  
por el usuario. No abra la fuente de alimentación. Dentro de la fuente de alimentación  
puede haber niveles de tensión, corriente y energía peligrosos. Devuélvala al fabricante  
para repararla.  
Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el  
cable de alimentación de la fuente de alimentación que va a reemplazar antes de extraerla  
del servidor.  
Para evitar el riesgo de descargas eléctricas, antes de abrir el servidor, apáguelo,  
desconecte el cable de alimentación, los sistemas de telecomunicaciones, las redes y los  
módems conectados al mismo.  
Advertencias sobre el cable de alimentación  
Si no se ha proporcionado con el producto ningún cable de alimentación de CA, adquiera  
alguno cuyo uso esté aprobado en su país.  
Precaución: Para evitar descargas eléctricas o fuego, revise los cables de alimentación que usará con  
el producto tal y como se describe a continuación:  
No intente modificar ni utilizar los cables de alimentación de CA si no son  
exactamente del modelo especificado para ajustarse a las tomas de corriente  
conectadas a tierra  
Los cables de alimentación deben reunir los siguientes requisitos:  
El cable de alimentación debe disponer de una capacidad nominal de corriente  
eléctrica mayor que la capacidad especificada en el producto.  
El cable de alimentación debe disponer de una patilla o contacto de conexión a tierra  
que sea apto para la toma de corriente.  
Los cables de la fuente de alimentación son los dispositivos de desconexión  
principales a la corriente alterna. El enchufe o enchufes de zócalo deben encontrarse  
cerca del equipo y el acceso a ellos debe poderse efectuar de forma inmediata con el  
fin de desconectarlos.  
®
®
56  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Los cables de la fuente de alimentación deben estar conectados a los enchufes con  
una toma de tierra adecuada.  
Advertencias el acceso al sistema  
Precaución: Para evitar lesiones personales o daños en la propiedad, se aplican las siguientes  
instrucciones de seguridad siempre que se acceda al interior del producto:  
Apague todos los dispositivos periféricos conectados a este producto.  
Pulse el botón de alimentación para apagar el sistema.  
Desconecte la alimentación de CA desenchufando los cables de alimentación de CA  
del sistema o de la toma de corriente alterna.  
Desconecte todos los cables y líneas de telecomunicación que estén conectados al  
sistema.  
Guarde todos los tornillos o elementos de fijación cuando retire las cubiertas de  
acceso. Cuando termine de operar en el interior del producto, vuelva a colocar los  
tornillos o los elementos de fijación originales de la cubierta de acceso.  
No acceda al interior de la fuente de alimentación. No hay elementos en la fuente de  
alimentación que usted pueda reparar y utilizar. Devuélvala al fabricante para  
repararla.  
Apague el servidor y desconecte todos los cables de alimentación antes de agregar o  
reemplazar cualquier componente que no es de conexión en funcionamiento.  
Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe  
el cable de alimentación de la fuente de alimentación que va a reemplazar antes de  
extraerla del servidor.  
Precaución: Si el servidor se ha estado ejecutando, los procesadores y disipadores de calor estarán  
recalentados. A no ser que esté instalando o extrayendo un componente de conexión en  
funcionamiento, deje que el sistema se enfríe antes de abrir las cubiertas. Para que no  
llegue a tocar los componentes que estén calientes cuando esté realizando una instalación  
de conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de  
conexión en funcionamiento.  
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el  
sistema se le ha suministrado con una protección para el ventilador, asegúrese de que  
cuando esté funcionando el sistema la protección esté en su sitio.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advertencias sobre el montaje en bastidor  
El bastidor del equipo se debe sujetar con un soporte fijo para evitar que se caiga cuando  
se extraiga un servidor o una pieza del mismo. El bastidor del equipo debe instalarse  
siguiendo las instrucciones del fabricante del bastidor.  
Instale el equipo en el bastidor comenzando desde la parte de abajo, con el equipo más  
pesado en la parte inferior del bastidor.  
Extraiga las piezas del equipo del bastidor de una a una.  
El usuario es el responsable de la instalación de un dispositivo de desconexión de la  
alimentación principal para toda la unidad del bastidor. El acceso a este dispositivo de  
desconexión deberá ser de fácil acceso y deberán incluirse indicaciones que lo  
identifiquen como el control de alimentación eléctrica de toda la unidad, no sólo de los  
servidores.  
Para evitar el riesgo de descargas eléctricas, deberá instalar una conexión a tierra  
apropiada para el bastidor y para cada pieza del equipo instalada en el mismo.  
Descarga electrostática (ESD)  
Precaución: Las descargas electrostáticas pueden dañar las unidades de disco, las tarjetas y otros  
componentes. Recomendamos que realice todos los procedimientos en una estación de  
trabajo protegida contra descargas electrostáticas. En caso de que no haya una  
disponible, protéjase de alguna forma contras las descargas llevando un brazalete  
antiestático conectado a la toma de tierra de la carcasa (cualquier superficie de metal  
que no esté pintada) del servidor cuando manipule las piezas.  
Manipule siempre las tarjetas con el máximo cuidado. Pueden ser sumamente sensibles a  
las descargas electrostáticas. Sujételas sólo por los bordes. Una vez extraída la tarjeta de  
su envoltorio de protección o del servidor, colóquela con el lado de los componentes  
hacia arriba sobre una superficie con toma de tiearra y sin carga estática. Utilice una  
almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la  
tarjeta. No deslice la tarjeta sobre ninguna superficie.  
®
®
58  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sustitución de la batería  
Precaución: Existe el peligro de explosión si la batería no se reemplaza correctamente. Al reemplazar  
la batería, utilice sólo la batería recomendada por el fabricante del equipo.  
Deseche las baterías respetando la normativa local.  
No intente recargar la batería.  
No intente desmontar, pinchar o causar cualquier otro desperfecto a una batería.  
Enfriamiento y circulación de aire  
Precaución: El tendido de los cables debe realizarse cuidadosamente tal y como se le indica para  
reducir al mínimo los problemas de obstrucción de la ventilación y de refrigeración.  
Para conseguir una refrigeración y corriente de aire adecuadas, compruebe que cuando  
sistema esté funcionando, las cubiertas de la carcasa están instaladas. Si utiliza el sistema  
sin las cubiertas, podría dañar sus componentes. Para instalar las cubiertas:  
Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del  
sistema.  
Compruebe que los cables, tarjetas adicionales y otros componentes están instalados  
correctamente.  
Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto.  
Periféricos o dispositivos láser  
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales:  
No abra la caja de ningún periférico o dispositivo láser  
Los periféricos o dispositivos láser no pueden ser reparados por el usuario  
Haga que el fabricante los repare.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
简体中文  
服务器安全信息  
本文档适用于 Intel® 服务器主板、Intel®  
服务器机箱(基座和机架固定件)和已安装的外设。为减少人身伤害、电击、火灾  
以及设备毁坏的危险,请在安装或维护 Intel®  
服务器产品之前阅读本文档并遵循本指南中的所有警告和预防措施。  
如果本文档中的信息与特定产品的随附信息或 Web  
站点信息之间存在不一致,请以产品文档为准。  
服务器须由合格的技术人员进行集成和维护。  
必须遵守本指南的规定和服务器手册的装配指导,以确保符合现有的产品认证和审  
批。仅使用本指南中描述和规定的指定组件。使用其他产品 / 组件将使产品的 UL  
认证和其他管理审批无效,并可能导致产品不符合销售地的产品法规。  
安全警告与注意事项  
为避免人身伤害与财产损失,安装本产品之前,请阅读以下所有安全指导和信息。  
下面所列的安全符号可能在整个文档中使用并可能标注于产品和 /  
或产品包装之上。  
注意  
警告  
表示如果无视此“? ? ? 项”? ? ? ? ? ? ? 轻微人身伤害或财产损失的危险。  
表示如果无视此“? ? ”? ? ? ? ? ? ? 严重人身伤害的危险。  
表示如果无视所示信息,即存在潜在的危险。  
表示如果不遵守安全指导,存在可导致严重伤害或死亡的电击危险。  
表示灼热组件或表面。  
表示请勿触摸风机叶片,否则可能致伤。  
表示拔下所有交流电线,断开交流电源  
®
®
60  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
预期应用使用  
根据评估,本产品为信息技术设备  
(ITE),可安装在办公室、学校、计算机房和类似的商业场所。本产品对于非 ITE  
应用的其他产品种类和环境(如医疗、工业、住宅、报警系统和测试设备)的适用  
性尚有待进一步的评估。  
场地选择  
本系统专为在典型办公环境运行而设计。请选择符合以下条件的地点:  
清洁、干燥,无气载微粒(而非一般的室内尘埃)。  
通风良好,远离热源(包括直接日晒和散热器)。  
远离振动源或物理震动。  
与电气设备产生的强大电磁场隔离。  
在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信  
线路与调制解调器之间的连接。  
提供正确接地的墙壁插座。  
提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。  
设备操作规范  
减少人身伤害或设备受损的危险:  
移举设备时遵守当地的职业健康与安全要求。  
借助机械手段或其他合适的手段移举设备。  
拆除一切易分离组件,以降低重量并方便操作。  
电源与电气警告  
注意事项  
电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接  
通电源,就存在 5V  
待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能  
不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除  
任何热插拔组件之前,确保交流电线已拔下。  
若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都  
需要一根单独的交流电线。  
本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设  
备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。  
替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其  
从服务器上移除。  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
为避免电击,请在打开服务器之前,关闭服务器并断开服务器上连接的电源线、电  
信系统、网络和调制解调器。  
电源线警告  
如果产品未提供交流电线,请购买一根您所在国家批准使用的交流电线。  
注意事项  
为避免电击或火灾危险,请按如下所述对产品所用的电源线进行检查:  
若非所需的符合接地插座的确切类型,请勿尝试修改或使用交流电线  
电源线须符合以下标准:  
电源线的电气额定值须大于产品上标注的电流额定值。  
电源线须拥有适合插座的安全接地插头或触点。  
电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。  
电源线须插入所提供的拥有合适接地的插座。  
系统使用警告  
注意事项  
为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用:  
关闭所有与本产品相连的外设。  
按下电源按钮至关闭状态,关闭系统。  
从系统或墙壁插座上拔下所有交流电线,断开交流电源。  
断开与系统相连的所有线缆和通信线路。  
卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请  
用螺钉或紧固件重新固定舱口盖。  
请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系  
维修事宜.  
增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线  
替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线  
,然后再从服务器上移除电源供应设备。  
注意事项  
如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加  
或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中  
接触灼热组件,移除或安装热插拔组件时务须小心。  
®
®
62  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
注意事项  
为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸  
下风机防护装置运行系统。  
机架固定件警告  
设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机  
架生产商提供的安装说明进行安装。  
从下往上将设备安装在机架上,最重的设备安装在机架的最底层。  
一次只从机架上安装一件设备。  
您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且  
须标明为控制整个装置(而不仅限于服务器)的电源。  
为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地  
静电放电 (ESD)  
注意事项  
ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD  
工作站的所有步骤。如果没有 ESD  
工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地  
或任何未喷漆金属表面连接的防静电腕带。  
操作主板时始终保持小心。它们可能对 ESD  
非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将  
主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要  
使用主板包装。请勿将主板在任何表面上滑动。  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
其他危险  
替换电池  
注意事项  
不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的  
电池。  
请按当地法规处置电池。  
请勿对电池充电。  
请勿拆卸、刺穿或以其他方式损坏电池。  
冷却和气流  
注意事项  
按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。  
为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行  
系统可能导致系统部件受损。安装机箱盖的步骤如下:  
首先检查并确保系统内没有遗留的未固定工具或部件。  
检查线缆、内插板和其他组件已正确安装。  
按产品说明安装机箱盖。  
激光外设或激光设备  
注意事项  
为避免幅射暴露和 / 或人身伤害:  
请勿打开任何激光外设或激光设备的外壳  
激光外设或激光设备为非用户维修设备  
请与生产商联系维修事宜  
®
®
64  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C Regulatory and Compliance  
Information  
Product Regulatory Compliance  
Product Safety Compliance  
The Server Board SE7230NH1-E complies with the following safety requirements:  
UL60950 - CSA 60950(USA / Canada)  
EN60950 (Europe)  
IEC60950 (International)  
CB Certificate & Report, IEC60950 (report to include all country national deviations)  
GOST R 50377-92 - Listed on one System License (Russia)  
Belarus License - Listed on System License (Belarus)  
CE - Low Voltage Directive 73/23/EEE (Europe)  
IRAM Certification (Argentina)  
Product EMC Compliance - Class A Compliance  
Note: Legally this product is required to comply with Class A emission requirements as it is  
intended for a commercial type market place. Intel targets 10db margin to Class A Limits.  
The Intel® Server Board [name] has been has been tested and verified to comply with the  
following electromagnetic compatibility (EMC) regulations when installed a compatible  
Intel® host system. For information on compatible host system(s) refer to Intel's Server  
Builder Web site or contact your local Intel representative.  
FCC /ICES-003 - Emissions (USA/Canada) Verification  
CISPR 22 - Emissions (International)  
EN55022 - Emissions (Europe)  
EN55024 - Immunity (Europe)  
CE - EMC Directive 89/336/EEC (Europe)  
AS/NZS 3548 Emissions (Australia / New Zealand)  
BSMI CNS13438 Emissions (Taiwan)  
GOST R 29216-91 Emissions - Listed on one System License (Russia)  
GOST R 50628-95 Immunity -Listed on one System License (Russia)  
Belarus License - Listed on one System License (Belarus)  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RRL MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea)  
Certifications / Registrations / Declarations  
UL Certification (US/Canada)  
CE Declaration of Conformity (CENELEC Europe)  
FCC/ICES-003 Class A Attestation (USA/Canada)  
C-Tick Declaration of Conformity (Australia)  
MED Declaration of Conformity (New Zealand)  
BSMI Certification (Taiwan)  
GOST - Listed on one System License (Russia)  
Belarus - Listed on one System License (Belarus)  
RRL Certification (Korea)  
Ecology Declaration (International)  
Product Regulatory Compliance Markings  
This product is marked with the following Product Certification Markings:  
Table 7. Product Certification Markings  
Regulatory  
Country  
USA/Canada  
Marking  
Compliance  
UL Mark  
CE Mark  
Europe  
FCC Marking (Class A) USA  
EMC Marking (Class A) Canada  
CANADA ICES-003 CLASS A  
CANADA NMB-003 CLASSE A  
®
®
66  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 7. Product Certification Markings  
Regulatory  
Country  
Marking  
Compliance  
BSMI Marking (Class A) Taiwan  
RLL MIC Mark  
Korea  
Electromagnetic Compatibility Notices  
FCC (USA)  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following  
two conditions: (1) this device may not cause harmful interference, and (2) this device  
must accept any interference received, including interference that may cause undesired  
operation.  
For questions related to the EMC performance of this product, contact:  
Intel Corporation  
5200 N.E. Elam Young Parkway  
Hillsboro, OR 97124-6497  
1-800-628-8686  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference in a residential installation. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and  
used in accordance with the instructions, may cause harmful interference to radio  
communications. However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or  
television reception, which can be determined by turning the equipment off and on, the  
user is encouraged to try to correct the interference by one or more of the following  
measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the receiver.  
Connect the equipment to an outlet on a circuit other than the one to which the  
receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Any changes or modifications not expressly approved by the grantee of this device could  
void the user's authority to operate the equipment. The customer is responsible for  
ensuring compliance of the modified product.  
Only peripherals (computer input/output devices, terminals, printers, etc.) that comply  
with FCC Class A or B limits may be attached to this computer product. Operation with  
noncompliant peripherals is likely to result in interference to radio and TV reception.  
All cables used to connect to peripherals must be shielded and grounded. Operation with  
cables, connected to peripherals, that are not shielded and grounded may result in  
interference to radio and TV reception.  
Industry Canada (ICES-003)  
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux  
appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur:  
"Apparelis Numériques", NMB-003 édictee par le Ministre Canadian des  
Communications.  
This digital apparatus does not exceed the Class A limits for radio noise emissions from  
digital apparatus set out in the interference-causing equipment standard entitled: "Digital  
Apparatus," ICES-003 of the Canadian Department of Communications.  
Europe (CE Declaration of Conformity)  
This product has been tested in accordance too, and complies with the Low Voltage  
Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked  
with the CE Mark to illustrate its compliance.  
Taiwan Declaration of Conformity (BSMI)  
The BSMI Certification Marking and EMC warning is located on the outside rear area of  
the product.  
®
®
68  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Korean Compliance (RRL)  
English translation of the notice above:  
1. Type of Equipment (Model Name): On License and Product  
2. Certification No.: On RRL certificate. Obtain certificate from local Intel  
representative  
3. Name of Certification Recipient: Intel Corporation  
4. Date of Manufacturer: Refer to date code on product  
5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
®
70  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
D Intel Server Issue Report Form  
Note: An on-line / automatic submission version of this form is available at http://  
support.intel.com/support/motherboards/server/SE7230NH1-E/. For the fastest service,  
please submit your form via the Internet.  
Date Submitted: _______________________________________________________  
Company Name: ______________________________________________________  
Contact Name: ________________________________________________________  
Email Address: _______________________________________________________  
Intel Server Product: ___________________________________________________  
Priority (Critical, Hot, High, Low): _______________________________________  
Brief Problem Description. Provide a brief description below. See the last page for space  
to include a detailed problem description.  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
Board / Chassis Information  
Baseboard Revision - PBA#: _____________________________________________  
Baseboard Serial Number: _______________________________________________  
Chassis Model:________________________________________________________  
CPU1 Speed/Stepping/Spec: _____________________________________________  
System BIOS Version: __________________________________________________  
HSC Firmware Version:_________________________________________________  
DIMM Configuration  
DIMM1A MB and Vendor / part number: ___________________________________  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIMM1B MB and Vendor / part number: __________________________________  
DIMM2A MB and Vendor / part number: __________________________________  
DIMM2B MB and Vendor / part number: __________________________________  
Operating System Information  
Operating System:_____________________________________________________  
Version: _____________________________________________________________  
Service Pack:_________________________________________________________  
Add-in Card, Peripheral, Video, NIC  
Check each box below as applicable, and provide the requested information.  
Peripheral Card or Peripheral Description Driver Revision IRQ # I/O Base Address NIC  
Driver  
Revision  
I/O Base  
Address  
FW  
Revision  
X
Peripheral  
Description  
IRQ  
Pedestal Slots  
PCI (32bit/33MHz)  
Slot 1  
PCI (32bit/33MHz)  
Slot 2  
PCI Express* x4  
(x1 Lane - Slot 3)  
PCI Express* x8  
(x4 Lane - Slot 4)  
PCI-X (64bit/  
100MHz)  
(Slot 5)  
PCI Express* x8  
(x8 Lane - Slot 6)  
Full-height Riser  
PCI Riser Slot  
Video  
On-board Video  
Add-in Video  
NIC  
On-Board NIC1  
On-Board NIC2  
®
®
72  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hard Drive Information  
Drive Type (SCSI,  
Hot-swapor  
Fixed  
FW  
Revision  
X
Make/Model  
IRQ  
SATA, etc)  
Management Information  
On-Board Platform Instrumentation only ___________________________________  
®
®
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Complete Problem Description  
In the space below, provide a complete description of the steps used to reproduce the  
problem or a complete description of where the problem can be found. Please also include  
any details on troubleshooting already done.  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
®
®
74  
Intel Server Board SE7230NH1-E and Intel Server Platform SR1475NH1-E User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  

InFocus Projector ScreenPlay 7210 User Manual
Ingersoll Rand Paint Sprayer 200G User Manual
Innotek Switch ADV 1000E User Manual
Intel Computer Hardware mPGA478 User Manual
JBL Stereo Amplifier LSR6325P 1 User Manual
Jotul Indoor Fireplace GI 425 DV User Manual
Keating Of Chicago Fryer 18 BB GAS User Manual
Kenwood Car Video System DDX8032BTM User Manual
Kettler Riding Toy 08838 790 User Manual
KitchenAid Ventilation Hood 423 User Manual