Honeywell M847D User Manual

Direct Drive Damper Actuator  
M847D  
Application  
The M847D is a two position, 24 Vac spring return damper  
actuator designed to operate directly driven zone dampers,  
used to control air flow in ducts. The synchronous motor  
actuator can be driven open (or closed) using any 24 volt  
rated two position switch - eg. a wall switch or a thermostat  
subbase switch.  
The M847D replaces the RDMH and RDMZ damper  
actuators for use on Trol-A-Temp® ARD and ZD dampers.  
Specifications  
Electrical Rating: 24 Vac 60 Hz 0.32 Amp., 8 VA  
Electrical Connection: 1/2" conduit  
Nominal Angular Rotation: 90° ( max. 105° )  
Torque: Min. 423 mNm (milli newton meter) [60 in.oz] output  
torque available when motor is energized and device is at  
the spring returned initial start position.  
Nominal Motor Timing: (@25°C ambient)  
Energized at rated load - 30 seconds.  
De-energized (spring return) - 10 seconds.  
Ambient Temperature Rating: 5 to 60°C (+40 to 140°F)  
Finish: zinc plated steel, anodized aluminium  
Direction of Shaft Rotation: clockwise, when energized  
and viewed from the base or shaft end.  
Mounting Means: direct connection to damper shaft.  
Mounting Position: Multi-poise.  
Dimensions: See Figure 1.  
Nominal Device Dimension  
A
B
C
D
8.2  
5/16  
E
31.5  
1-1/4  
F
19.3  
3/4  
mm  
in  
60  
2-3/8  
84.5  
3-3/8  
88  
3-1/2  
G
15.8  
5/8  
H
58.6  
2-5/16 1-3/16  
J
29.3  
K
33.5  
1-5/16  
L
6.4  
1/4  
M
40.4  
1-9/16  
mm  
in  
Fig. 1 - Dimensional Details  
INSTALLATION AND CHECKOUT  
WARNING  
1. DO NOT install this actuator on a flue damper.  
!
CAUTION  
1. Readtheseinstructionscarefully.Failuretofollowthemcould  
cause a hazardous condition.  
2. DO NOT attempt to rotate the actuator by turning the  
connection coupling or the damper shaft when it is  
connected to the actuator or damage to the gear train  
may occur.  
2. Disconnect powersupply before beginning of installation and  
wiring of control to prevent electrical shock or equipment  
damage.  
3. Check the ratings given in the instructions and on the product  
to make sure the product is suitable for your application.  
4. Allwiringmustcomplywithlocalelectricalcodes, ordinances,  
and regulations.  
5. Installer must be a trained, experienced service technician.  
6. After installation is complete, check out the product operation  
as provided in these instructions.  
STANDARD MOUNTING (For 5/16" dia. damper shaft)  
The M847D can be attached directly to the protruding 5/16"  
diameter damper shaft using the sleeve of the output shaft. Drill  
A 5/16" (8mm) hole 1-5/16" (33.5mm) directly below the damper  
shaft opening to accept the anti-rotation shaft protruding from  
the base of the motor. The length of the damper shaft to which  
the connection coupling is attached is such as to firmly hold the  
actuator in a position to adequately engage the anti-rotation pin  
in the warm air duct. See Figure 1. for the critical dimensions.  
11-01 © Honeywell Limited. 2001 • Form Number: 95C-10905-1  

Brother MFC 8380DN User Manual
Carrier AIR COOLED CONDENSING UNITS 38AD User Manual
Champion Manufacturing Air Conditioner DNH_ 018 User Manual
Epson Printer FX 890 User Manual
Fujitsu Air Conditioner ASU18T User Manual
GE PDW9880J User Manual
Haier 0010571223 User Manual
Hitachi RAM 72Q5 User Manual
HP Hewlett Packard Hewlett Packard All in One Printer HP PART NUMBER_ 461487 401A User Manual
HP Hewlett Packard Photosmart C7100 User Manual