		 SERVICE REFERENCE   
					Installation, Operation   
					DIVISION   
					SALES   
					4 
					SECTION UB   
					and   
					(Supersedes PF417-13)   
					REFERENCE   
					PF417-14   
					RENEWAL PARTS IDENTIFICATION   
					161-048445-001   
					DATE   
					July, 2002   
					Type UB-1002E, UB-1252E, UB-1502E, UB-2002E   
					Forced-Air Heaters   
					Dimensions —   
					Ceiling Line   
					17-1/8”   
					13-3/4”   
					6” Min. Spacing to   
					Adjacent Wall   
					Back   
					Wall   
					3”   
					For Lower Height   
					from Ceiling:   
					Customer to Add   
					Extention Strap   
					4-7/8”   
					Min.   
					Wall   
					20-3/4”   
					Mounting   
					Holes Center   
					8”   
					12-1/4”   
					6”   
					10”   
					8”   
					11-3/4”   
					7/8” and 1-23/32”   
					Dia. Holes in Rear   
					9-5/16”   
					Rubber Feet Provided for   
					Wall Mount Model Only.   
					17-11/16”   
					Figure 2   
					Mounting UB using Wall   
					Mounting Brackets*   
					7’-0” Min. Height   
					Above Floor   
					Figure 1   
					Mounting UB using   
					Ceiling Mounting   
					Brackets*   
					7’-0” Min.   
					Height Above   
					Floor   
					*Wall and/or Ceiling Mounting Brackets are   
					available as an accessory option — Contact   
					your local sales representative.   
					Specifications —   
					Horizontal   
					Air   
					Discharge   
					‡ 
					Model   
					Volts and Phase   
					kW   
					UB-1002E   
					UB-1252E   
					UB-1502E   
					UB-2002E   
					UB-2002E   
					208 - 240 - 480 (1 or 3)   
					208 (3) - 240 (3) - 480 (1 or 3)   
					208 (3) - 240 (1 or 3) - 480 (1 or 3)   
					240 (1 or 3)   
					10   
					12.5   
					15   
					40’   
					40’   
					45’   
					45’   
					45’   
					19.9   
					20   
					208 (3) - 480 (1 or 3)   
					‡ Models with suffix “T” added (480 volts only) are equipped with a transformer, 480 volt primary — 120/240 volt secondary.   
					‡ Models with suffix “R” added are equipped with a relay (Example: UB-1002E-R 240 volt or 480 volt — 3 phase only).   
					MOUNTING   
					C.In either case, minimum mounting height is 7 feet from   
					WARNING: Hazard of Electric Shock. Disconnect all   
					floor to bottom of heater (see Figures 1 and 2).   
					2. Spacing to adjacent walls   
					power before installing heater.   
					Note: These heaters are designed for wall or ceiling mounting   
					only. Other modes of mounting voids factory warranty.   
					1. Height above floor   
					A.Rear of case to back wall 4-7/8” minimum (see Figure 2).   
					B. Side of case to side wall 6” minimum (see Figure 2).   
					3. If two or more units are operated in the same enclosed space,   
					their discharges should be directed to aid in development of   
					mass air movement for uniform heat dispersal.   
					A.In areas where ceiling height is more than 12 feet, recom-   
					mended mounting height is approximately 10 feet to under-   
					side of heater.   
					4. Controlling thermostats to individual heaters should be   
					B. For ceiling heights of 12 feet or less, maximum mounting   
					height is determined by use of ceiling mounting brackets   
					offered for these heaters. Minimum spacing to ceiling is 3”   
					(see Figure 2).   
					mounted at shoulder height on inside walls or columns.   
					© 2010 Chromalox®, Inc.   
				WIRING DIAGRAMS   
					Figure 4   
					Use with:   
					UB-1002E-T   
					480V, 1Ø or 3Ø   
					Alternate 240V Wiring   
					1 or 3 Phase, 60 Cycle   
					Power Supply 480 Volts   
					X4   
					X1   
					X3   
					X2   
					} 
					Heater Bank   
					UB-1252E-T   
					480V, 1Ø or 3Ø   
					Integral 480V/240V   
					or 120V Transformer   
					1Ø Motor   
					Fused   
					120V Wiring   
					X2   
					Switch   
					X1   
					X3   
					X4   
					Contactor   
					Heater   
					Thermal   
					Cutout   
					UB-1502E-T   
					480V, 1Ø or 3Ø   
					H1   
					H2   
					Control   
					Switch Optional   
					Transformer   
					Fusing   
					UB-2002E-T   
					480V, 1Ø or 3Ø   
					Ground   
					This Wiring   
					by Customer   
					Wiring Comp't   
					Baffle   
					Thermostat   
					When Used   
					C1   
					T1   
					T2   
					F1   
					For 3 Phase Only   
					F2   
					L1   
					L2   
					L3   
					Figure 5   
					Use with:   
					UB-1002E-R   
					208V, 1Ø or 3Ø   
					240V, 1Ø or 3Ø   
					480V, 1Ø or 3Ø   
					Heater Bank   
					1 or 3 Phase, 60 Cycle Power   
					Supply 208, 240 or 480 Volts   
					1Ø Motor   
					} 
					Heater   
					UB-1252E-R   
					208V, 3Ø   
					240V, 3Ø   
					Control   
					Source 120 or   
					240 Volts, 60 Cycle   
					Fused   
					Switch   
					Integral   
					Cutout   
					480V, 1Ø or 3Ø   
					Cutout   
					UB-1502E-R   
					208V, 3Ø   
					240V, 3Ø   
					Fused   
					Control Switch   
					This Wiring   
					by Customer   
					Ground   
					Wiring Comp't   
					Baffle   
					Thermostat   
					When Used   
					480V, 1Ø or 3Ø   
					C1   
					C2   
					L1   
					L2   
					For 3 Phase Only   
					UB-2002E-R   
					480V, 1Ø or 3Ø   
					240V, 3Ø   
					L3   
					Figure 6   
					Use with:   
					UB-1002E-TR   
					480V, 1Ø or 3Ø   
					Alternate 240V Wiring   
					X4   
					Heater Bank   
					1 or 3 Phase, 60 Cycle Power   
					Supply 480 Volts   
					1Ø Motor   
					X1   
					X3   
					X2   
					} 
					Cutout   
					UB-1252E-TR   
					480V, 1Ø or 3Ø   
					Integral 480V/240V   
					or 120V Transformer   
					120V Wiring   
					Heater   
					X2   
					X1   
					X3   
					X4   
					UB-1502E-TR   
					480V, 1Ø or 3Ø   
					Fused   
					Switch   
					Integral   
					Cutout   
					H1   
					H2   
					UB-2002E-TR   
					480V, 1Ø or 3Ø   
					Control   
					Switch Optional   
					Thermostat   
					When Used   
					Ground   
					This Wiring   
					by Customers   
					Wiring Comp't   
					Baffle   
					T1   
					T2   
					C1   
					C2   
					L1   
					For 3 Phase Only   
					L2   
					L3   
					Transformer   
					Fusing   
				WIRING DIAGRAMS   
					Figure 7   
					Use with:   
					UB-1002E-R   
					208V, 1Ø or 3Ø   
					240V, 1Ø or 3Ø   
					Heater Bank   
					1 or 3 Phase, 60 Cycle   
					Power Supply 208 or 240 Volts   
					1Ø Motor   
					} 
					UB-1252E-R   
					208V, 3Ø   
					240V, 3Ø   
					Heater   
					Cutout   
					Integral   
					Contactor   
					Fused   
					Switch   
					UB-1502E-R   
					208V, 3Ø   
					240V, 3Ø   
					Thermostat   
					When Used   
					This Wiring   
					Ground   
					Wiring Comp't   
					Baffle   
					bny Customer   
					T1   
					T2   
					For 3 Phase Only   
					L1   
					L2   
					L3   
				RENEWAL PARTS IDENTIFICATION   
					1 
					3 
					4 
					8 
					2 
					MOTORS   
					208V   
					Heating   
					Element   
					Thermal   
					Cutout   
					Model   
					Volts Phase   
					Fan   
					Transformer   
					120V   
					240V   
					300-049200-002 1 (1)   
					300-049200-002 3 (1)   
					UB-1002E   
					UB-1002E   
					208   
					240   
					1 or 3   
					1 or 3   
					118-045311-001 (3)   
					118-045311-002 (3)   
					193-302120-009   
					193-302120-009   
					193-302120-009   
					—————   
					—————   
					112-045422-001   
					112-045422-001   
					112-045422-001   
					—————   
					—————   
					300-049200-002 1 (1)   
					300-049200-002 3 (1)   
					193-302120-009   
					300-049200-002 1 (1)   
					300-049200-002 1 (1)   
					UB-1002E*   
					UB-1252E   
					UB-1252E   
					480   
					208   
					240   
					1 or 3   
					3 
					118-045311-003 (3)   
					118-045311-004 (3)   
					118-045311-005 (3)   
					193-302120-009   
					193-302120-009   
					193-302120-009   
					—————   
					193-302120-009   
					—————   
					193-302120-009   
					—————   
					315-303675-001   
					—————   
					112-045422-001 300-049200-002 3 (1)   
					300-049200-002 1 (1)   
					112-045422-001   
					1 or 3   
					193-302120-009   
					—————   
					300-049200-002 3 (1)   
					300-049200-002 1 (1)   
					112-045422-001   
					UB-1252E*   
					UB-1502E   
					UB-1502E   
					480   
					208   
					240   
					1 or 3   
					3 
					118-045311-006 (3)   
					118-045307-001 (3)   
					118-045307-002 (3)   
					193-302120-009   
					193-302120-009   
					193-302120-009   
					—————   
					193-302120-009   
					—————   
					193-302120-009   
					—————   
					315-303675-001   
					—————   
					300-049200-002 3 (1)   
					112-045422-002 300-049200-006 3 (1)   
					300-049200-006 1 (1)   
					112-045422-002   
					1 or 3   
					193-302120-009   
					—————   
					300-049200-006 3 (1)   
					UB-1502E*   
					UB-2002E   
					480   
					208   
					1 or 3   
					3 
					118-045307-003 (3)   
					118-045307-004 (3)   
					193-302120-009   
					193-302120-009   
					—————   
					193-302120-009   
					—————   
					112-045422-002 300-049200-006 (1)   
					112-045422-002 300-049200-006 (1)   
					315-303675-001   
					—————   
					193-302120-009   
					300-049200-006 1 (1)   
					112-045422-002   
					UB-2002E   
					240   
					480   
					1 or 3   
					1 or 3   
					118-045307-009 (3)   
					118-045307-006 (3)   
					193-302120-009   
					193-302120-009   
					—————   
					—————   
					193-302120-009   
					193-302120-009   
					—————   
					300-049200-006 3 (1)   
					UB-2002E*   
					112-045422-002 300-049200-006 (1)   
					315-303675-001   
					Note: Part numbers suffixed by a number in ( ) indicates quantity of same part number used.   
					*Note: Fuse 3A 600V KTK-3 — 128-047763-007 (2)   
					Fuse BLK Barrier — 129-048475-001 (1)   
					Fuse Block — 129-048473-001 (2)   
				RENEWAL PARTS IDENTIFICATION   
					9 RELAYS   
					Model   
					Volts   
					Phase   
					kW   
					Motor   
					Relay   
					Model   
					Volts   
					Phase   
					kW   
					Motor   
					Relay   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1002E   
					UB-1252E   
					UB-1252E   
					UB-1252E   
					UB-1252E   
					UB-1252E   
					UB-1252E   
					UB-1252E   
					UB-1252E   
					208   
					208   
					208   
					208   
					240   
					240   
					240   
					240   
					480   
					480   
					480   
					480   
					208   
					208   
					240   
					240   
					480   
					480   
					480   
					480   
					1 
					1 
					3 
					3 
					1 
					1 
					3 
					3 
					1 
					1 
					3 
					3 
					3 
					3 
					3 
					3 
					1 
					1 
					3 
					3 
					10   
					10   
					120V   
					208V   
					120V   
					208V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					072-303180-008   
					072-303180-014   
					072-303180-007   
					072-303180-013   
					072-303180-008   
					072-303180-014   
					072-303180-007   
					072-303180-013   
					072-303180-011   
					072-304551-015   
					072-303180-007   
					072-303180-013   
					072-303180-008   
					072-303180-014   
					072-303180-008   
					072-303180-014   
					072-303180-011   
					072-304551-015   
					072-303180-007   
					072-303180-013   
					UB-1502E   
					UB-1502E   
					UB-1502E   
					UB-1502E   
					UB-1502E   
					UB-1502E   
					UB-1502E   
					UB-1502E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					UB-2002E   
					208   
					208   
					240   
					240   
					480   
					480   
					480   
					480   
					208   
					208   
					240   
					240   
					240   
					240   
					480   
					480   
					480   
					480   
					3 
					3 
					3 
					3 
					1 
					1 
					3 
					3 
					3 
					3 
					1 
					1 
					3 
					3 
					1 
					1 
					3 
					3 
					15   
					15   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					208V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					120V   
					240V   
					072-303180-008   
					072-303180-014   
					072-303180-008   
					072-303180-014   
					072-303180-008   
					072-303180-014   
					072-303180-007   
					072-303180-013   
					——————   
					——————   
					——————   
					——————   
					072-303180-008   
					072-303180-014   
					072-303180-008   
					072-303180-014   
					072-303180-007   
					072-303180-013   
					10   
					15   
					10   
					15   
					10   
					15   
					10   
					15   
					10   
					15   
					10   
					15   
					10   
					20   
					10   
					20   
					10   
					19.9   
					19.9   
					19.9   
					19.9   
					20   
					10   
					12.5   
					12.5   
					12.5   
					12.5   
					12.5   
					12.5   
					12.5   
					12.5   
					20   
					20   
					20   
					PARTS COMMON TO ALL HEATERS   
					5 Wall Bracket Set . . . . . . . . . . . . . . . . . . . . . . .168-026844-003   
					6 Ceiling Mounting Support (Includes 7 ) . . . . .027-044419-003   
					7 Ceiling Suspension Brackets . . . . . . . . . . . . . .027-033363-001 (2)   
					10 Louver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182-047073-003   
					11 Grille . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134-119147-003   
					12 Motor Mounting Frame . . . . . . . . . . . . . . . . . .194-045314-001   
					Note: Part Numbers suffixed by a number in ( ) indicates quantity of same part number used.   
					Limited Warranty:   
					Please refer to the Chromalox limited warranty applicable to this product at   
					
					2150 N. RULON WHITE BLVD., OGDEN, UT 84404   
					Phone: 1-800-368-2493   
					
				 |