I35MB - 3.5”
Mirrored Hard Disk
Operations Manual
March 2006
Rev. 003
PN: 610200094
Table of Contents
Introduction
1
2
Aborting a button press
14
I35MB Features
1
2
Using the I35MB Rail Kit
15
Related Documents
S.M.A.R.T. (Self-Monitoring, Analysis and
Reporting Technology) Attributes
I35MB Jumper Settings
Setting Master/Slave and Cable Select
Setting a Remote-Mounted Activity LED
Interface Connectors
I35MB Installation
16
17
3
3
S.M.A.R.T Attribute Table
S.M.A.R.T Attribute Notes
LED Indicators
18
4
4
19
IDLE State – No host access
ACTIVE State – Host access
I35MB Dimension Drawings
Appendix I
19
20
Introduction
4
5
6
Inserting the I35MB
21
22
23
23
24
Removing the I35MB
Basic Operation
6
Sales and Technical Support
Standard Warranty
Partitioning and Formatting
Operating System Installation
I35MB LEDs and Mirror Control Buttons
Mirror Control Button Functions
Advanced Operations
Managing Faults
6
6
7
8
Revision Control
8
8
9
Bank Hard Faults
Bank Soft Faults
9
Turning the Buzzer Off
Changing Media
10
10
12
13
13
13
Resetting Mirroring Indicators
Rebuilding a bank
Rebuilding a Bank Off-line
Using Different Size Media
i
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Introduction
The Adtron™ Diskpak™ Model I35MB with Adtron ActiveRAID™ technology
incorporates RAID-1 mirroring in a 3.5-inch hard disk form factor. RAID-1 mirroring
between two hard disk drives provides data redundancy and rebuild independent
from the host CPU. With both disk drives functioning properly, the I35MB keeps
both disk drives automatically updated. If one of the drives fails, the system
continues to operate on a single disk drive until the I35MB is removed from the
chassis and the failed drive is replaced. When the I35MB is reconnected and
powered up, a rebuild can be initiated on the I35MB concurrent with host activity.
Once the rebuild is manually started, it continues unattended until complete.
ActiveRAID technology significantly reduces the probability of a data storage failure
causing an overall system failure.
LEDs, Buzzer, and
Mirror Control
buttons
Bank 1
Bank 0
Flex Cable
40-pin Connector
Power Connector
IDE Jumper Options
Figure 1 I35MB
I35MB Features
•
Adtron ActiveRAID™ technology, featuring RAID-1 mirrored disk drives
independent of host CPU
•
ATA/ATAPI-5 ANSI NCITS340-2000 compliant; supporting PIO, Multiword
DMA, and Ultra DMA interfaces and transfer rates
•
•
Standard IDE 40-pin connector, high speed parallel ATA interface
S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) Attributes
(Refer to the section of this manual titled S.M.A.R.T. Attributes for more
information)
•
•
•
•
•
Audio and visual indicators warn of faults
Operator initiated, automatic rebuild functions transparent to the host CPU
Host operations continue with a single faulted disk drive or during a rebuild
Full error detection and management without host intervention
Field upgradeable firmware prevents future obsolescence
1
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Related Documents
•
•
•
ANSI NCITS 340-2000 ATA/ATAPI-5 Specification
I35MB Product Specification
I35MB Installation Manual
Static Sensitive – The I35MB is a static sensitive device. While setting
jumpers, take precautions to ensure that static does not discharge into the
I35MB.
I35MB Jumper Settings
The master/slave and remote LED jumper is located on the front of the I35MB,
between the IDE and power connectors. This jumper is used to set master, slave,
cable select configurations and to mount a remote Activity LED. Refer to Figure 2 for
the location of this jumper.
The following figure shows the jumper location on the I35MB:
IDE jumper options
39
1
5
6
1
4
1
40
2
2
40-pin connector
Power connector
Figure 2 I35MB Jumper Locations
2
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Setting Master/Slave and Cable Select
This IDE jumper is only for the configuration of master, slave, cable select and to
mount a remote Activity LED. Figure 3 shows the pins of the IDE jumper on the
I35MB.
3
4
7
8
1
2
5
6
Master Setting
3
4
7
8
1
2
5
6
Slave Setting
3
4
7
8
5
6
1
2
Cable Select Setting
Figure 3 IDE Jumper
When a jumper is placed on pins 3 and 4, the I35MB is the master device (default).
With a jumper placed on pins 1 and 2, the I35MB is the slave device. When a jumper
is placed on pins 1 and 3, the cable select configuration is utilized. Refer to the above
Figure for pins and jumper placements.
Setting a Remote-Mounted Activity LED
A remote-mounted Activity LED may be used with the I35MB. Refer to Figure 4 for
the pin location and setting.
-EXTLED
3
4
7
8
5
6
1
2
+3.3V
Through 120 ohm on-board resistor
Figure 4 I35MB Remote LED
Pins 5 and 6 in Figure 4 are used for a remote-mounted Activity LED. Pin 6 runs
through a 120 Ohm resistor to +3.3V. See the I35MB Product Specification for signal
descriptions.
3
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Interface Connectors
The I35MB has an interface connector located on the front panel. Using an 80-
conductor cable (40-pin connector); connect the I35MB to the primary or secondary
ports on the IDE controller. Plug a power cable from the computer’s power supply
into the I35MB power connector. The I35MB does not require 12V. Refer to the
Figure below, for the location 40-pin connector and power supply.
4-pin Power
connector
40-pin connector
Figure 5 I35MB interface
I35MB Installation
Introduction
The I35MB is a 3.5-inch hard disk drive and mounts into a standard 3.5-inch hard
disk drive bay. The drive may be mounted from the side or the bottom.
DO NOT exceed the maximum insertion depth of 3.8mm [.150”] from drive edge.
Consider the length of the screw used and thickness of the mounting surface. A
common screw length of 3/16” is provided, but may not be correct in all
applications.
Refer to Figure 6 on page 5 for mounting hole locations.
Static Sensitive - The I35MB is a static sensitive device. When installing
and uninstalling the I35MB, take precautions to ensure that static does not
discharge into the I35MB.
4
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Inserting the I35MB
To install the I35MB in the hard disk drive bay:
1. Power down the computer and remove the cover.
2. Make sure that you are properly grounded.
3. Set the master/slave to desired configurations. By default, the I35MB is set to
master.
4. Select a 3.5-inch drive bay that houses either a floppy or hard disk. If the chassis
provides a front removable panel, the buzzer reset and fault LEDs can be viewed
by removing the plastic panel on the chassis.
5. Using an 80-conductor cable (40-pin connector) connect the I35MB to the IDE
primary or secondary IDE ports.
6. Connect the power supply to the I35MB.
7. Mount the I35MB into the appropriate disk drive bay, using screws to secure the
I35MB in the chassis. See Figure 6 for mounting holes, screw size and maximum
depth.
8. Put the cover on the chassis and screw it down.
9. Power on the computer.
6-32 x 3.8mm[.150"] MAX. DEPTH
Figure 6 Mounting Holes
5
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Removing the I35MB
To remove the I35MB from the hard disk drive bay:
1. Make sure that you are properly grounded.
2. Power down the computer.
3. Remove the chassis casing.
4. Disconnect the 80-conductor cable and the computer power supply cable from
the I35MB.
5. Unfasten the mounting screws and remove the I35MB from the disk drive bay.
Basic Operation
The I35MB operates as a storage subsystem that can be used as a boot device or as
additional storage.
Partitioning and Formatting
To the operating system, the I35MB looks like a single disk drive. All RAID-1
functions occurring in the I35MB are transparent to the operating system. Use the
operating system utilities to partition and/or format the I35MB hard disk drive.
Operating System Installation
The I35MB can be formatted like any standard hard disk drive – bootable for
operating system function or not bootable. Any standard disk partitioning and
formatting utility can be used. Any operating system chosen that is compatible with
IDE devices will be acceptable for use with the I35MB. The method of installing a
specific operating system can vary, so consult the operating system documentation
for instructions.
6
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
I35MB LEDs and Mirror Control Buttons
Activity LED
D10
Bank 0 Fault LED
D12
Bank 1 Access LED
Bank 0 Access LED
D11
D13
Bank 1 Fault LED
D14
S4
S2
S3
Bank 1 Mirror Control
Buzzer Reset Bank 0 Mirror Control
Figure 7 LEDs and Mirror controls
The LEDs are used to indicate individual Bank status (access/fault), media activity
(read/writes) and Mirror status. Table 1 describes LED states, mirror status and
controls.
The following table describes the LED states:
Activity LED (D10)
Green
Orange - flashing
Description
No access; Power is on
Reads or writes occurring on hard disk
Orange – flashing in a Indicates an issue with the I35MB
set pattern
Bank LED
D11
D12
Description
Bank 0 access
Bank 0 fault
Color - State
Green solid – Power on
Orange solid – Hard fault
Orange flashing – Soft fault
Green solid – Power on
Orange solid – Hard fault
Orange flashing – Soft fault
D13
D14
Bank 1 access
Bank 1 fault
Mirror Control
Description
Function
S4
Buzzer reset
Audible alarm indicates
error. Push button to turn
off.
S2
S3
Bank 0 Mirror control
Bank 1 Mirror control
Controls Bank 0 mirroring
Controls Bank 1 mirroring
Table 1 I35MB LED states and Mirror controls
7
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Mirror Control Button Functions
The following figure shows the location of the mirror control buttons and LEDs on
the I35MB.
Bank 1 Mirror control
Bank 0 Mirror control
Buzzer Reset
Figure 8 Mirror Control Button operations
The following table describes the different operations using the Mirror Control
button on either bank. Press and hold Mirror Control button to activate the functions
listed in Table 2.
Button Press Duration Bank Access LED Feedback
Function
0 – 5 seconds
5 – 10 seconds
10 – 15 seconds
15 – 20 seconds
> 20 seconds
LED flashes slow (1/sec)
LED flashes medium (2/sec) Mirror Rebuild
LED flashes fast (4/sec)
LED solid on
LED off
Power up or down bank
No Operation
Reserved
No Operation
Table 2 Mirror Control Button operations
Functions marked reserved are for Adtron factory use only. Contact
technical support for more details. In the case of a button press duration
that reaches 15 seconds, DO NOT release until after 20 seconds to save
future operations.
Advanced Operations
The individual banks may be taken off-line (powered down and/or replaced) at any
time, for preventative maintenance or due to a failure. However, taking a bank
offline automatically faults the mirror, requiring a rebuild. To clear a hard or soft
fault, the rebuild must complete.
Managing Faults
The I35MB has two fault indicators: hard and soft. Refer to page 19, for the specific
bank fault LED indicators to interpret these two types of faults.
8
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Adtron recommends having a system back-up available prior to managing hard
or soft faults.
Bank Hard Faults
Hard fault errors may originate from any one of the following:
•
•
•
Write errors
Track 0 Not Found read error
HDD Timeout after a command
If a hard fault occurs on one bank, the I35MB continues to read and write data to the
other functioning bank. The I35MB is running in a degraded mode, which should be
corrected as soon as possible. When the I35MB detects a hard fault, the faulted drive
is taken offline and the RAID-1 operation between the drives is broken. The audible
buzzer sounds and the bank fault LED turns solid orange. If this occurs, the faulted
drive must be replaced. See Turning the Buzzer Off on page 10 for more
information.
Adtron recommends regularly backing up data; and, should a fault occur,
scheduling a replacement and rebuild as soon as possible.
If either a hard or soft fault occurs while the I35MB is running in a
degraded mode, the I35MB sends an error code to the host and continues
to operate.
Bank Soft Faults
Soft fault errors are caused by a read error on a drive. If a soft fault occurs, the I35MB
continues to mirror data to both drives, but is running in a degraded mode, which
should be corrected as soon as possible. The bank with the soft fault remains online
with a continuously flashing orange bank fault LED. The soft fault can only be reset
by rebuilding the faulted drive; or, replacing it and then performing a rebuild. Refer
to Rebuilding a Bank on page 13. At this time, one of two actions is required:
•
•
Rebuild the faulted drive
Replace and rebuild the faulted drive
9
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Rebuilding the faulted drive may take several hours, depending on the size
of the media and may result in a hard fault if the drive cannot “map” around
any “bad” sectors. While rebuilding can result in a reliable storage device
and workable drive, Adtron recommends replacing the drive in the field that
exhibits a soft fault and then rebuilding and testing this drive in a non-
critical test environment to determine if this drive can be used as a spare.
Turning the Buzzer Off
The audible buzzer goes off when a hard fault occurs on one of the two disk drives.
When a hard fault occurs, the RAID-1 mirror is broken and maintenance is required.
To turn the buzzer off:
1. If possible, pop the removable plastic panel off the drive bay in which the I35MB
is installed. If the I35MB does not have front access through a drive bay,
continue with Changing Media on this page.
2. Depress the Buzzer Reset button, labeled S4 in Figure 7 on page 7.
3. Note the bank number, 0 or 1, with the fault LED turned solid orange. This is the
bank that requires attention.
4. Schedule a time to power down the computer and remove the I35MB.
Changing Media
Static Sensitive - The I35MB is a static sensitive device. Take
precautions to ensure that static does not discharge into the I35MB.
To change the bank with the fault:
1. Make sure you are appropriately grounded.
2. If accessible from the front cover, pop the faceplate off the bay with the I35MB
inserted. Push the Buzzer Reset button (S4) on the I35MB to turn off audible
alarm, if applicable.
10
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
3. Note the bank number, 0 or 1, with the fault LED turned solid orange. This is the
bank that requires attention.
4. Power down the computer.
5. Remove the computer cover and locate the I35MB in the disk drive bay.
6. Disconnect the power supply and 80-conductor cable from the I35MB.
7. Unscrew the chassis mounting screws and slide the I35MB out of the disk drive
bay.
8. On the side opposite the flex cables, loosen the retaining screw for the faulted
disk drive.
9. Gently unseat the drive to a disengaged distance, approximately ¼ of an inch,
causing the flex cables to bow in a loop. (Refer to Figure 10.) Carefully
disconnect the flex cable from the faulted disk drive. Detaching the drives from
the flex cable in a forceful manner will damage the flex cable.
Flex Cable
Flex cables are extremely
fragile and should be handled
IDE Connector
Bank 1
Bank 0
with care when attaching,
reattaching and/or
disconnecting. Not doing so will
cause irreversible damage. If
during any of the actions listed,
IDE Connector
Bank 0
Bank 1
the flex cable becomes
damaged or unusable, please
contact Adtron Technical
Support.
Retaining Screws
Figure 9 Flex Cable and Retaining Screws
10. Slide the drive out of its carrier.
11. Insert a new, working disk drive of the same capacity (or greater) with rails
installed into the carrier.
Flex Cables
Figure 10 Flex Cable View
11
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
12. Before the disk drive is fully seated (approximately ¼ of an inch to the drive
being fully seated) re-attach the flex cable to the disk drive. Refer to Figure 10 for
a view of this procedure. Carefully align and slowly attach. Pay close attention to
mounting the flex cable. Ignoring this procedure and caution can lead to damage
in future operations.
13. Tighten the retaining screw for the new disk drive.
14. The I35MB may be re-inserted in the disk drive bay, as described in Inserting the
I35MB on page 5 of this document. If your computer system does not provide
front access to the I35MB when it is installed in the bay, then connect the I35MB
to the primary or secondary ports on the IDE controller and power cable external
to the computer system to do the rebuild. The front LEDs and buttons must be
available to do the rebuild.
15. After securing the I35MB, a rebuild must be performed. Go to Rebuilding a
Bank on page 13.
Resetting Mirroring Indicators
The procedure below provides steps to reset the mirror indicators on the I35MB.
These steps address mirror indicators and DO NOT address resetting mirroring data
or data equilibrium. In addition, following these steps will only ensure subsequent
writes will be mirrored. For more information on resetting mirroring operations
beyond mirror indicators, refer to the section of this manual titled, Rebuilding a
Bank, on page 13.
Static Sensitive - The I35MB is a static sensitive device. Take
precautions to ensure that static does not discharge into the I35MB.
To reset mirror operations and change both banks:
1. While power is OFF, verify both banks are unpopulated.
2. Cycle the I35MB power to the ON state (for 5 seconds or more), then the OFF
state.
3. Insert media into desired banks.
4. Cycle power ON.
5. Once powered ON, all subsequent writes will be mirrored.
12
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Rebuilding a bank
After a bank has been replaced, a rebuild must be performed. To start a Bank
Rebuild, press the mirror control button between 5 and 10 seconds on the off-line
bank. Release the button when the Access LED starts flashing at 2 blinks per second.
The rebuild process begins, indicated by the Access LED turning solid green and the
Fault LED flashing green. When complete, the Fault LED changes from flashing
green to off. It is faster to do the rebuild when there is no host activity to the I35MB.
A rebuild operation copies the contents of the entire media at a rate of
roughly 5 MB/sec, requiring several hours for large capacities. Depending
on concurrent host activity, the rebuild process may be slowed. The higher
the level of concurrent host activity, the more the rebuild process may be
impacted (slowed).
Rebuilding a Bank Off-line
Only the power connection is required to do the rebuild if you want to have a
rebuild complete before bringing the drive on line. No host activity interruption
results in the fastest rebuild time.
Using Different Size Media
The I35MB can support different size drives in each bank and still operate the
mirroring function. The rules for this operation are as follows:
Media inserted to replace the factory original must have a capacity that is equal to or
greater than the original media size.
The capacity of the mirrored unit remains the same size as when shipped from the
factory. In other words, if the drive shipped from the factory with a capacity of
20GB, it will retain that capacity regardless of the actual capacity of the media in
either bank.
Any media inserted into a bank that is smaller than the original capacity can not be
used for mirroring. Rebuild attempts to a smaller media will not start. The LEDs will
indicate a mirror fault condition.
13
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Examples:
A new I35MB is installed in the field with two 20GB capacity media for 20GB of
mirrored storage. Bank 1 requires replacement. A 10GB media is installed and
the button pressed for rebuild. Rebuild will not start and the mirror remains
broken.
A 40GB media is then inserted in Bank 1. The rebuild copies the data from the
Bank 0 20GB drive to the new drive in Bank 1. The I35MB remains a 20GB
mirrored device.
Bank 0 media is replaced with a 60GB unit. The rebuild copies the operational
20GB from Bank 1. The I35MB now has a 40GB media in the Bank 1 and a
60GB drive in Bank 0. The I35MB remains a 20GB mirrored device.
Contact Adtron Technical support for more information regarding using
different size media.
Aborting a button press
If the bank button is pressed for longer than 20 seconds, no operation is performed.
This is provided as an opportunity to abort a button press.
14
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Using the I35MB Rail Kit
The following steps describe the process to disassemble and reassemble hard disk
drives on the I35MB. Attention to individual instructions is necessary to ensure
functionality and avoid damage to the device. Please contact Adtron Sales if
assembling hard disk drives other than those provided by Adtron, and refer to the
section of this manual titled, Using Different Size Media. Refer to Appendix # 1 for
a list of supplies that are included with the I35MB Rail Kit Installation.
Static Sensitive - The I35MB is a static sensitive device. Take
precautions to ensure that static does not discharge into the I35MB.
1. Position rail retention screw (#1) through left rail (#2), align screw with
corresponding hard disk, bottom side mounting hole and screw gently into place
(avoid tightening screw until second retention screw is also aligned and screwed
into place). Firmly tighten both screws but do not over tighten.
2. Repeat assembly sequence from step 1, with the right rail (# 3). Align the drive
assembly retention screw (# 4) with the left rail (# 2) as illustrated and screw
gently into place. Avoid tightening the drive assembly screw until step 4.
3. Adhere chassis ground protection barrier1 (# 5) to the rear edge of the drive.
4. Align the completed hard disk drive assembly on the I35MB guide rails and slide
into place. Attach the drive power and signal flex cable, which will require
pulling the drive slightly out to accommodate assembly. Lastly, gently tighten
the drive assembly retention screw into place, ensuring drive does not extend
beyond the I35MB footprint, then firmly tighten the screw. Refer to Changing
Media, on page 10, for detailed instructions for attaching flex cables and
connecting the hard disk drive.
3
1
4
2
5
Figure 11 I35MB Rail Kit
1 Important: Should a drive be replaced and a new drive assembled with the original I35MB Rail Kit, a new chassis ground protection
material will be required. For example, Adtron suggests Kapton tape.
15
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology)
Attributes
The Adtron Diskpak I35MB incorporates an array of S.M.A.R.T. attributes and
capabilities that provide significant amounts of information relating to the life
history of the hard disk drive (HDD). S.M.A.R.T. is a monitoring system for
computer (HDDs) to detect and report on various indicators of reliability, with the
intent of anticipating failures. The user or system administrator can send a query
using S.M.A.R.T. technology to retrieve requested data. This provides time to
anticipate drive failure and to take preventive action — such as copying the data to a
replacement device.
The I35MB incoporates:
•
•
•
•
Operational Attribute Data
User and manufacturing log pages
Error Log pages
Self-test
Using RAID-1 mirroring techniques, the I35MB duplicates data using two disk
interfaces that are referred to as Bank 0 and Bank 1. The user can determine the
status of the data mirror as a whole, as well as each bank individually, using
industry- standard S.M.A.R.T commands. The S.M.A.R.T. Attributes that specifically
apply to the I35MB are summarized below, and a more detailed description appears
in Table 3.
Contact Adtron for more S.M.A.R.T. details.
Attribute #121: Hard Fault – Bank 0: Attribute
identifies the Bank 0 media that has
experienced a hard fault.
Attribute #110: Hardware Configuration:
Attribute identifies configuration as RAID-1
and identifies the media interfaces that exist.
Attribute #122: Hard Fault – Bank 1: Attribute
identifies the Bank 1 media that has
experienced a hard fault.
Attribute #111: Media Presence: Attribute
identifies whether media was present on those
interfaces at last power-up.
Attribute #125: Soft Fault – all Media: Attribute
identifies all the media that has experienced a
soft fault.
Attribute #112: Reset to Ready Timer: Attribute
identifies the time in milliseconds from
power-up until this logical unit indicated it
was ready.
Attribute #126: Soft Fault – Bank 0: Attribute
identifies the Bank 0 media that has
experienced a soft fault.
Attribute #113: Rebuild Activity Completion
Estimate: Attribute provides an estimate of the
percentage of time remaining until the rebuild
activity is complete.
Attribute #127: Soft Fault – Bank 1: Attribute
identifies the Bank 1 media has experienced a
soft fault.
Attribute #120: Hard Fault – all Media:
Attribute identifies all the media that has
experienced a hard fault.
16
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
S.M.A.R.T Attribute Table
S.M.A.R.T attributes are vendor specific parameters that are used in evaluating the
status of the device. Adtron specific S.M.A.R.T attributes are listed below. Many
tools used to display S.M.A.R.T. attributes may not recognize Adtron specific
attributes. Refer to Table 3 to identify Adtron specific S.M.A.R.T. attributes.
Attribute
Number
(8 bits)
Name
Value
(8 bits)
Raw Data
(eight, 8-bit bytes)
Threshold
9 (0x09)
12 (0x0C) Power cycle count
Power on hours
Reserved for future use
Reserved for future use
110
(0x6E)
Hardware
configuration
1: RAID-0
2: RAID-1
(Note 110)
64-bit field showing which
media interfaces are present
0
111
(0x6F)
112
(0x70)
(Note 112)
Media presence
Reset to ready
0
0
64-bit field showing which
media are present
Time from start to reset process
to when this LU indicated
READY in the host interface,
milliseconds
0
0
113
(0x71)
Rebuild remaining
0
16-bit value:
0
0x0000: no rebuild activity
0xFFFF: rebuild starting
else: “percent” (ffff..0) remaining
64-bit field showing which
media
120
(0x78)
121
(0x79)
(Note 120a)
Hard fault
(all media)
Hard fault
200: all media OK
<200: some bad
200: all mirrors
OK
<200: some bad
200: all mirrors
OK
199
0
64-bit field showing which
media
(1st member)
(Note 120b)
122
(0x7A)
(Note 120a)
Hard fault
64-bit field showing which
media
0
(2nd member)
(Note 120b)
<200: some bad
123
(0x7B)
(Note 120a)
Hard fault
Reserved for future use
(3rd member)
(Note 120b)
125
(0x7D)
(Note 120a)
Soft fault
(all media)
(Note 120b)
200: all media OK
<200: some faulted media
64-bit field showing which
198
0
126
(0x7E)
(Note 120a)
Soft fault
200: all mirrors
OK
<200: some faulted
200: all mirrors
OK
64-bit field showing which
media
(1st member)
(Note 120b)
127
(0x7F)
(Note 120a)
Soft fault
64-bit field showing which
media
0
(2nd member)
(Note 120b)
<200: some faulted
128
(0x80)
(Note 120a)
Soft fault
Reserved for future use
(3rd member)
(Note 120b)
17
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Attribute
Number
(8 bits)
Name
Value
(8 bits)
Raw Data
(eight, 8-bit bytes)
Threshold
(Note 194)
194
(0xC2)
199
(0xC7)
(Note 199)
Temperature
Degrees C
0
0
UltraDMA error
count
0
Unsigned integer
Table 3 S.M.A.R.T. Attributes
S.M.A.R.T Attribute Notes
Note
Description
110
This value does not conform to the ATTRIBUTE value/threshold model. The value literally
indicates the number of members in each mirror set.
112
The reset-to-ready attribute reports elapsed time from start of hard reset to the end of hard or
soft reset. If a soft reset is received, the value could be quite large and misleading.
This attribute only available in mirrored units.
1st, 2nd, 3rd refer to mirror banks. For RAID-0, only Bank 1 exists; for RAID-1, Banks 0 and 1
exist; more banks are defined for future expansion, but not currently implemented.
Adtron temperature can report negative values, and other manufacturers cannot. The
attribute value is degrees C, and the first byte of the raw data field is fractional degrees C. For
example, value = 0x20 and raw [0] = 0x80 means 0x20.80 (hexadecimal), or 32.5 decimal.
The DMA error counter is reset to zero with any hard reset.
120a
120b
194
199
Table 4 S.M.A.R.T. Attribute Notes
18
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
LED Indicators
IDLE State – No host access
Bank Access LED
(Green/Orange)
Bank Fault LED
(Green/Orange)
Drive Activity LED
(Green/Orange)
Bank State
Description
Normal
GREEN
OFF
OFF
GREEN
GREEN
No host access
Button pushed while
on-line.
Request off-line GREEN flashing
(1/sec)
Fully off-line
Fully off-line,
faulted
OFF
OFF
OFF
ORANGE
GREEN
GREEN
Replace drive and
rebuild (Hard fault).
Request on-line GREEN flashing
(1/sec)
See Note 1
OFF
GREEN
ORANGE
GREEN
Becoming on-
line
OFF
Button released,
processing
Replace drive and
rebuild.
Drive removed OFF
ORANGE
Drive reinserted OFF
Request rebuild GREEN flashing
(2/sec)
ORANGE
See Note 1
GREEN
GREEN
Must perform rebuild
Rebuilding
GREEN
GREEN flashing GREEN
(2/sec)
Button released,
processing. May take 6
hours or more.
Rebuild
complete
Soft Fault
GREEN
GREEN
OFF
OFF
GREEN
GREEN
GREEN
Immediately resume
normal operations.
Bank read fault
ORANGE
flashing (1/sec)
ORANGE
Hard Fault
Replace drive and
rebuild.
Table 5 Inactive LED states
1 Depends on previous LED state: OFF = Online, ORANGE = Fault.
19
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
ACTIVE State – Host access
Bank Access LED Bank Fault LED
Drive Activity LED
(Green/Orange)
Bank State
(Green/Orange)
(Green/Orange)
Description
Normal
GREEN
OFF
ORANGE
Host access in progress
(reads or writes)
Button pushed while on-
line.
Button released,
processing request.
Request off-line GREEN flashing OFF
(1/sec)
Becoming off-
line
ORANGE
ORANGE
GREEN
OFF
Fully off-line
Request on-line GREEN flashing See Note 1
(1/sec)
OFF
OFF
ORANGE
ORANGE
Becoming on-
line
OFF
OFF
ORANGE
Button released,
processing.
Drive removed OFF
ORANGE
ORANGE
ORANGE
ORANGE
Replace drive and rebuild.
Must perform rebuild.
Drive
OFF
reinserted
Request rebuild GREEN flashing See Note 1
(2/sec)
ORANGE
Rebuilding
GREEN
GREEN flashing ORANGE
Button released,
processing. May take 6
hours or more.
Immediately resume
normal operations.
Bank read fault.
(2/sec)
OFF
Rebuild
complete
Soft Fault
GREEN
GREEN
OFF
ORANGE
ORANGE
ORANGE
ORANGE
flashing (1/sec)
Hard Fault
ORANGE
Replace drive and rebuild.
Table 6 Active LED states
1 Depends on previous LED state: OFF = Online, ORANGE = Fault
20
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
I35MB Dimension Drawings
25.3 .997
101.6 4.000
Figure 11 I35MB
21
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Appendix I
The table below lists the parts supplied on the I35MB Rail Kit. Items numbers
correspond with Figure 11, under the section of this document titled, Using the
I35MB Rail Kit.
Item Number
Quantity
Description
# 1
# 2
# 3
# 4
# 5
Four (4)
One (1)
One (1)
One (1)
Two (2)
Rail Retention Screw (M3 x 5)
Rail – Left
Rail – Right
Drive Assembly Retention Screw (M2. 5x9)
Chassis Ground Protection Barrier
Table 7 Parts Supplied
22
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Sales and Technical Support
Contact Adtron Corporation for technical support, application questions, data sheets,
and documentation. Our normal business hours are Monday through Friday, 8am to
5pm, MST.
Headquarters – Sales
Europe - Sales
Adtron Corporation
4415 E. Cotton Center Blvd.
Phoenix, AZ 85040
Tel:
Fax:
+41-56-496-5640
+41-56-496-5648
Email: [email protected]
Tel:
Fax:
+1-602-735-0300
+1-602-735-0359
Nordic - Sales
Tel: +45-4557-0754
Fax: +45-4557-0753
Email: [email protected]
Email: [email protected]
Germany – Sales
Tel: +49-821-589-9914
Fax: +49-821-589-7190
Email: [email protected]
United States – Technical Support
Europe – Technical Support
Tel:
Fax:
+1-602-735-0300
+1-602-735-0359
Tel:
Fax:
+45-4557-0754
+45-4557-0753
Email: [email protected]
Email: [email protected]
Web Site
Standard Warranty
Adtron warrants this product to be free from defects in materials and workmanship
for the duration of the warranty period. If this product fails within the warranty
period due to such defect, Adtron will repair or replace this product.
This warranty does not apply if this product has been damaged by abuse, accident,
disaster, misuse or incorrect installation.
23
Rev. 003, PN: 610200094
Adtron I35MB Operations Manual
Revision Control
Rev
Author Date
Sections
Description
001
002
003
JMH
JMH
JMH
Apr 2005
Aug 2005
Mar 2006
All
Original
Connector
SMART, Rail Kit
8-pin change to the connector
Adding SMART attributes/ and
information. Rail Kit guide.
24
Rev. 003, PN: 610200094
|