IMC Networks Switch iMcV Switch User Manual

iMcV-Switch  
Operation Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
FCC Radio Frequency Interference Statement ....................................................ii  
Warranty............................................................................................................ii  
About the iMcV-Switch ......................................................................................1  
Installing the iMcV-Switch ..................................................................................1  
Unmanaged Modules.........................................................................................2  
Specifications.....................................................................................................6  
Fiber Optic Cleaning Guidelines.........................................................................7  
Electrostatic Discharge Precautions.....................................................................7  
IMC Networks Technical Support.......................................................................8  
Certifications......................................................................................................8  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About the iMcV-Switch  
The iMcV-Switch is a 5-port Ethernet module that allows the user to increase the port  
density and service area of Ethernet networks. The store and forward switch function  
allows the user to extend Ethernet service to locations a total of 100 meters from the  
Ethernet source. All RJ-45 ports Auto Negotiate 10/100BaseT, full/half duplex, and  
automatically configure for MDI or MDIX operation. Each port allows a maximum  
frame size of up to 1916 bytes, with support for Flow Control and priority queuing.  
Each SFP or fixed fiber port supports 100 Mbps FDX; the fiber is available in a variety  
of SM and MM types, including SSF.  
Priority Queuing  
The iMcV-Switch supports two levels of priority queuing at the egress of every port.  
All frames with high priority will egress the port ahead of low priority frames at a 10:1  
ratio. Priority is determined, first, through VLAN Tag priority. If no VLAN Tag is  
available then the DiffServ (ToS) bits are used. The VLAN Tag priority is based on a 3  
bit PRI word where the base priority is set to “4”. Values of 4 or greater have high  
priority.  
Flow Control  
Flow Control is based on the outcome of the Auto Negotiate function. If Flow  
Control is enabled then a port will stop transmitting frames when a PAUSE frames is  
received. When the internal buffers become congested the unit will send PAUSE  
frames to all congested ports. Frames will be dropped if no internal buffer space is  
available at ingress.  
Installing the iMcV-Switch  
The iMcV-Switch is a media converter module that provides 5-port 10/100 Auto  
Negotiating Ethernet ports. The module can be installed in any iMediaChassis,  
MediaChassis or IE-MediaChassis series.  
Managed Modules  
In order to manage an iMcV-Switch, an SNMP agent must be present in the chassis.  
To manage the module, first install the module into the chassis. After installing IMC  
Network’s free SNMP software, iView², port status per port can be monitored. There  
is no port configuration; the Graphical User Interface (GUI) provides LED status  
information only. SFP’s with DDMI will not offer an SFP Table through iView².  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unmanaged Modules  
The iMcV-Switch is an unmanaged 5-port 10/100 module; there are no DIP Switch  
settings to configure. If installed in an unmanaged chassis, the LEDs will indicate the  
status of each port.  
Port LEDs  
The ports on the iMcV-Switch include diagnostic LEDs that indicate unique  
information about the port functionality and status.  
iMcV-Switch TX/5  
For all units with 5 copper ports, the two LEDs associated with each twisted pair port  
are defined as follows:  
Port  
LED  
Name  
Color  
OFF  
GREEN  
Flash GREEN  
OFF  
Function  
No link signal detected on copper port  
Copper port is receiving sync signal  
Activity is detected on the port  
Port is operating in half duplex  
Port is operating in full duplex  
LNK/ACT  
FDX  
TX  
GREEN  
Flash GREEN  
Flashes when port is set to HDX and collisions occur  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
iMcV-Switch TX/4 + SFP  
For all units with 4 copper ports, the two LEDs associated with each twisted pair port  
are defined as follows:  
Port  
LED  
Name  
Color  
OFF  
GREEN  
Flash GREEN  
OFF  
GREEN  
Flash GREEN  
OFF  
Function  
No link signal detected on copper port  
Copper port is receiving sync signal  
Activity is detected on the port  
Port is operating in half duplex  
Port is operating in full duplex  
Flashes when port is set to HDX and collisions occur  
No SFP installed  
LNK/ACT  
FDX  
TX  
FX  
LNK/ACT  
GREEN  
Flash GREEN  
Glows green when Link is established  
Flashes GREEN w/Activity  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
iMcV-Switch TX/3 + 2SFP  
For all units with 3 copper ports, the two LEDs associated with each twisted pair port  
are defined as follows:  
Port  
LED  
Name  
Color  
OFF  
GREEN  
Flash GREEN  
OFF  
GREEN  
Flash GREEN  
OFF  
GREEN  
Flash GREEN  
OFF  
Function  
No link signal detected on copper port  
Copper port is receiving sync signal  
Activity is detected on the port  
Port is operating in half duplex  
Port is operating in full duplex  
Flashes when port is set to HDX and collisions occur  
No SFP installed  
LNK/ACT  
FDX  
TX  
FX  
SFP  
A
FX  
SFP  
B
LNK/ACT  
LNK/ACT  
Glows green when Link is established  
Flashes GREEN w/Activity  
No SFP installed  
GREEN  
Flash GREEN  
Glows green when Link is established  
Flashes GREEN w/Activity  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
iMcV-Switch-TX/3 + FX  
For all units with 3 copper ports, the two LEDs associated with each twisted pair port  
are defined as follows:  
Port  
LED  
Name  
Color  
OFF  
GREEN  
Flash GREEN  
OFF  
GREEN  
Flash GREEN  
OFF  
Function  
No link signal detected on copper port  
Copper port is receiving sync signal  
Activity is detected on the port  
Port is operating in half duplex  
Port is operating in full duplex  
Flashes when port is set to HDX and collisions occur  
No link  
LNK/ACT  
FDX  
TX  
FX  
LNK/ACT  
GREEN  
Link at 100 Mbps  
Flash GREEN  
Activity is detected on the fiber port  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Industry Standards  
IEEE 802.3x Ethernet Standards  
IEEE 802.3u Auto Negotiation Standards  
Ethernet Connections: 10/100 BaseT, Auto Negotiation, AutoCross, Flow Control,  
1916 MTU, Full Line - Rate Forwarding  
Power Consumption (typical)  
TX/5  
0.19A @ 5V  
0.57A @ 5V  
0.6 5A @ 5V  
0.444A @ 5 V  
TX/4 + SFP  
TX/3 + 2SFP  
TX/3 + FX  
Operating Temperature  
32° to 122° F (0° to 50° C)  
Operating Power  
2.5W  
Storage Temperature  
-31° to 158° F (-35° to 70° C)  
Humidity  
5 to 95% (non-condensing); 0 to 10,000 ft. altitude  
Dimensions  
4.19” x .78” x 2.75” (106.4 mm x 19.81mm x 69.85 mm)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fiber Optic Cleaning Guidelines  
Fiber Optic transmitters and receivers are extremely susceptible to contamination by  
particles of dirt or dust, which can obstruct the optic path and cause performance  
degradation. Good system performance requires clean optics and connector ferrules.  
1. Use fiber patch cords (or connectors, if you terminate your own fiber) only from  
a reputable supplier; low-quality components can cause many hard-to-diagnose  
problems in an installation.  
2. Dust caps are installed at IMC Networks to ensure factory-clean optical devices.  
These protective caps should not be removed until the moment of connecting  
the fiber cable to the device. Should it be necessary to disconnect the fiber  
device, reinstall the protective dust caps.  
3. Store spare caps in a dust-free environment such as a sealed plastic bag or box  
so that when reinstalled they do not introduce any contamination to the optics.  
4. If you suspect that the optics have been contaminated, alternate between  
blasting with clean, dry, compressed air and flushing with methanol to remove  
particles of dirt.  
Electrostatic Discharge Precautions  
Electrostatic discharge (ESD) can cause damage to any product, add-in modules or  
stand alone units, containing electronic components. Always observe the following  
precautions when installing or handling these kinds of products  
1. Do not remove unit from its protective packaging until ready to install.  
2. Wear an ESD wrist grounding strap before handling any module or component.  
If the wrist strap is not available, maintain grounded contact with the system unit  
throughout any procedure requiring ESD protection.  
3. Hold the units by the edges; do not touch the electronic components or gold  
connectors.  
4. After removal, always place the boards on a grounded, static-free surface, ESD  
pad or in a proper ESD bag. Do not slide the modules or stand alone units over  
any surface.  
WARNING! Integrated circuits and fiber optic components are  
extremely susceptible to electrostatic discharge damage. Do not  
handle these components directly unless you are a qualified service  
technician and use tools and techniques that conform to accepted  
industry practices.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMC Networks Technical Support  
Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);  
+32-16-550880 (Europe)  
Fax: (949) 465-3020  
Certifications  
CE: The products described herein comply with the Council Directive on  
Electromagnetic Compatibility (2004/108/EC).  
Class 1 Laser product, Luokan 1 Laserlaite,  
Laser Klasse 1, Appareil A’Laser de Classe 1  
European Directive 2002/96/EC (WEEE) requires that any equipment that bears this  
symbol on product or packaging must not be disposed of with unsorted municipal  
waste. This symbol indicates that the equipment should be disposed of separately  
from regular household waste. It is the consumer’s responsibility to dispose of this  
and all equipment so marked through designated collection facilities appointed by  
government or local authorities. Following these steps through proper disposal and  
recycling will help prevent potential negative consequences to the environment and  
human health. For more detailed information about proper disposal, please contact  
local authorities, waste disposal services, or the point of purchase for this equipment.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
19772 Pauling • Foothill Ranch, CA 92610-2611 USA  
TEL: (949) 465-3000 • FAX: (949) 465-3020  
© 2009 IMC Networks. All rights reserved.  
The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any  
errors that may appear in this document. iMcV-Switch is a trademark of IMC Networks. Other brands or product names  
may be trademarks and are the property of their respective companies.  
Document Number 52-80445-01 A0  
December 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Accessories PD216493B User Manual
Graco Baby Accessories PD247333A User Manual
Graco Food Saver 312071D User Manual
Graco Inc Baby Playpen ISPP072AA 07 0632 User Manual
Harbor Freight Tools Air Compressor 67698 User Manual
Hearth and Home Technologies Outdoor Fireplace Montana 36 User Manual
Hotpoint Cooktop 5TCC User Manual
Hotpoint Ventilation Hood HD90X User Manual
HTC Cell Phone SM TP008 1125 User Manual
Hypertec Carrying Case 6701HY User Manual