At A Glance  
1
Warnings and Introduction  
ReAd And SAve THeSe InSTRUcTIOnS  
Important Safety Instructions: Read all instructions before using this humidifier.  
• This humidifier may not work properly on an uneven surface. ALWAYS place this humidifier on a firm, level, and water  
resistant surface.  
ALWAYS place the humidifier at least six (6) inches away from walls, heat sources, and electrical appliances such as  
stoves, radiators, or heaters.  
ALWAYS place the humidifier in an area that is out of the reach of children.  
• Before using the humidifier, extend the cord and inspect for any signs of damage. dO nOT use the product if the cord  
has been damaged.  
• This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized  
outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified  
electrician. dO nOT attempt to defeat or override this safety feature.  
ALWAYS UnPLUG And eMPTY the humidifier when it is not in operation or while it is being cleaned.  
• Use only clean, cool tap water when filling the tank. dO nOT use hot water.  
• Never add medication of any type to the water tank.  
You should never leave the unit unattended in a closed room. The room can become saturated and leave condensation  
on walls and furniture. Always leave a door partially open.  
• This part has been tested and complies with part 18 of the FCC.  
Thank you for purchasing The Ultrasonic Humidifier by Hunter Fan Company. Please read and save these instructions to receive the  
maximum benefit and performance from your humidifier.  
3
©2010 Hunter Fan Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  
At A Glance  
1
Know Your Humidifier  
Tank Handle  
Mist Exhaust  
Tank  
Tank Cap  
Control Knob  
Demineralization  
Cartridge Indicator  
Indicator  
Reset Button  
Refill Tank Light  
Silver Ion  
Demineral  
Oꢁ  
Reꢀll Tank  
Demineralization  
Cartridge Reset Button  
Vapor Pad  
Compartment  
4
44065-01 • 11/02/2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using Your Humidifier  
2
Initial Setup and Operation  
Initial Setup:  
1. Remove the plastic bag covering from the humidifier.  
Tank Handle  
2. Unravel and straighten the cord before use.  
3. Remove the tank from the humidifier base by grasping the tank handle, Figure  
4. If you plan to use a demineralization cartridge, insert it now into the base of  
Figure 1  
5. If you will be using a vapor pad in the unit, turn the base over and remove the  
vapor pad compartment grill. Insert 1 vapor pad into the compartment and  
6. Turn the tank upside down and twist the tank cap counter-clockwise to remove.  
7. If you plan to use a silver ion cartridge, drop it into the tank now.  
8. Fill the unit with clean, cool tap water.  
Silver Ion  
Demineral  
Warning: Never fill the humidifier with hot water.  
Oꢁ  
Reꢀll Tank  
9. Place the tank cap back on the tank and turn clockwise till secure.  
Figure 2  
10. Seat the tank back into the humidifier base making sure the tank is seated  
securely.  
Tank Cap  
nOTe: Failure to ensure the tank is seated correctly could cause the unit to leak  
water from the tank.  
11. Plug the humidifier into a wall outlet and start the unit.  
Figure 3  
Demineralization  
Cartridge  
Figure 4  
Figure 5  
5
©2010 Hunter Fan Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Using Your Humidifier  
2
Controls  
Operation:  
Humidity control:  
Demineral  
Silver Ion  
The output control allows you to set the amount of humidity you want  
the unit to output. Turn the knob clockwise to increase output. To turn the  
unit off, turn the the humidity knob past the lowest setting to off.  
Oꢁ  
Reꢀll Tank  
Indicators:  
Figure 6  
Silver Ion Indicator: When the silver ion indicator lights up, it is time to replace the  
silver ion cartridge in the tank, if you are using one. Simply remove the silver ion  
cartridge in the tank and drop in a new one. Hold the reset button down under  
the indicator for a few seconds until the light goes out to reset.  
Demineral Indicator: When the demineral indicator lights up, it is time to replace  
the demineralization cartridge in the base of the unit, if you are using one. Remove  
the tank from the unit, and the demineralization cartridge should be sittng inside  
the water tray in the bottom. Hold the reset button down under the indicator for a  
few seconds until the light goes out to reset.  
Refill Tank Indicator: This indicates the tank is out of water. Once you have refilled  
the tank with water and set it back onto the unit, the refill tank light will reset.  
6
44065-01 • 11/02/2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Maintenance  
3
Cleaining and Storage  
note: ALWAYS unplug the humidifier from the electrical outlet before cleaning.  
neveR allow water to sit in the tank when not in use.  
daily Maintenance:  
1. Turn off the humidifier and unplug it from the wall outlet.  
2. Remove the tank unit by pulling it straight off the humidifier base.  
3. Turn the tank upside down and drain any water into a sink or tub. Shake the  
unit gently to remove any remaining water.  
4. Rinse the tank thoroughly with water, empty, and wipe with a dry, clean cloth.  
5. Wipe the humidifier base with a dry cloth if necessary.  
6. Refill the tank as directed under “Initial Setup and Operation” on page 5 and  
resume use.  
Weekly Maintenance:  
1. Turn off the humidifier and unplug it from the wall outlet.  
2. Remove the tank unit by pulling it straight off the humidifier base.  
3. Turn the tank upside down and drain any water into a sink or tub. Shake the  
unit gently to remove any remaining water.  
4. Fill the Water Tank with a mixture of one (1) gallon of water and eight (8)  
ounces of white vinegar. Leave the mixture in the Water Tank for 20 minutes,  
giving the Water Tank a shake every few minutes. After 20 minutes, give the  
Water Tank a final shake and discard the mixture.  
5. Rinse the Water Tank several times with clean water. Leave the Water Tank  
Cap off to allow the Water Tank to dry completely.  
6. Wipe the surfaces of the main housing with a soft damp cloth.  
7. Once all the parts are clean and dry, reassemble the humidifier, refill the  
water tank, and resume use.  
note: The tank has built-in antimicrobial properties to inhibit the growth of  
bacteria, mold, and fungi that may affect the water in the tank. Daily and weekly  
maintenance is still necessary to prevent the growth of bacteria, mold, and fungi.  
end of Season Maintenance:  
1. Follow the instructions for weekly maintenance before storing the unit.  
2. Ensure all parts are completely dry before storing the unit.  
3. Store the unit in a cool dry place.  
4. Never store the unit with water in the tank.  
7
©2010 Hunter Fan Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Humidifier Assistance  
4
Troubleshooting  
Problem:  
Excessive noise.  
Solution:  
1. Check the Water Tank to make sure it is properly seated on the base.  
2. Check the Water Tank to make sure there are no bubbles when the Water Tank  
is full and running. If there are bubbles, turn the unit OFF until the bubbling stops.  
When the bubbling has stopped, set the unit to the desired speed.  
Problem:  
Humidifier not working.  
Solution:  
1. Make sure the Power Knob is not set to OFF.  
2. Adjust the humidity level using the Humidity Knob. Once the room reaches the  
set humidity level, the humidifier will turn OFF; this is normal.  
Problem:  
Mineral build-up on the Water Tank or Tray.  
Solution:  
1. Refer to the section “Cleaning and Storage” on page 8.  
Problem:  
Humidity output and water usage decreased.  
Solution:  
1. Check the Humidistat Knob and Power Knob to make sure they are set to the  
desired humidity level and speed.  
2. Check the Water Tank to make sure there are no bubbles when the Water Tank  
is full and running. If there are bubbles, turn the unit OFF until the bubbling stops.  
When the bubbling has stopped, set the unit to the desired speed.  
3. Clean any components that have mineral build-up. Refer to the section”Cleaning  
and Storage” on page 7.  
8
44065-01 • 11/02/2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Humidifier Assistance  
4
Service Parts and Support  
Service Parts  
Part  
Part # Part Name  
Replace  
89755-  
Water Tank  
01-326  
G0843-  
Tank Assembly Cap  
01-679  
Demineralization  
31954  
1 per month  
1 per month  
Cartridge  
Silver Ion  
31955  
Cartridge  
Technical Support  
If you need any assistance with setup, operation, or parts for your new Hunter  
Humidifier, please call us, our technical support staff is ready to help!  
USA: 1-888-830-1326  
canada: 1-866-268-1936  
Hours of operation are from 7:00 am to 7:00 pm Monday - Friday and 8:00 am  
to 5:00 pm on Saturday, Central Time. You may also contact us over the Internet  
at www.hunterfan.com or register your product at www.hunterfan.  
com/register and select your product under product registration.  
9
©2010 Hunter Fan Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Humidifier Accessories  
Treatments  
5
Model  
Product  
evaporative  
Ultrasonic  
vaporizer  
Warm Mist  
31955  
Cleaning Cartridge  
   
   
31954  
31961  
Demineralization Cartridge  
Vapor Steam  
   
31956  
31960  
Vapor Pads  
   
   
Water Treatment Tablets  
Notes  
10  
44065-01 • 11/02/2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
6
3 Year Guarantee  
The Hunter Fan Company, Inc. makes the following warranty to the original  
residential user or consumer purchaser of the ultrasonic humidifier:  
If any part of the ultrasonic humidifier fails during the first 3 (three) years from the  
date of purchase due to a defect in material or workmanship, we will provide a  
replacement part free of charge.  
If no replacement part can be provided, we will replace your humidifier.  
IF THE ORIGINAL RESIDENTIAL USER OR CONSUMER PURCHASER CEASES  
TO OWN THE HUMIDIFIER, THIS WARRANTY AND ANY IMPLIED WARRANTY  
WHICH THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY  
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS  
WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING  
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR  
FITNESS FOR A PARTICULAR PURPOSE IS EXPRESSLY LIMITED TO THE PERIOD  
OF THE EXPRESS WARRANTY SET FORTH ABOVE.  
This warranty is voided if your ultrasonic humidifier is not purchased and used in  
the USA or Canada.  
This warranty excludes and does not cover defects, malfunctions, or failures of  
the humidifier which were caused by repairs by persons not authorized by us,  
use of parts, or accessories not authorized by us, mishandling, modifications, or  
damage to the humidifier while in your possession, or unreasonable use, including  
failure to provide reasonable and necessary maintenance. This warranty does  
not cover humidifiers used in commercial applications. There are no express or  
implied warranties as to commercial purchasers or users.  
To obtain service, contact the nearest Hunter authorized service center or the  
Hunter Fan Company Service Department, 7130 Goodlett Farms Pkwy., Suite  
400, Memphis, TN 38016, 1-888-830-1326. You will be responsible for  
insurance and freight or other transportation to our factory service center. We  
will return the humidifier freight prepaid to you. The humidifier should be properly  
packaged to avoid damage in transit since we will not be responsible for any  
such damage. Proof of purchase is required when requesting warranty service.  
The purchaser must present the sales receipt or other document that establishes  
proof of purchase.  
IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT,  
INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS  
OF THE PURCHASE PRICE OF THE HUMIDIFIER. YOUR SOLE REMEDY WILL BE  
REPAIR OR REPLACEMENT AS PROVIDED ABOVE. SOME AMERICAN STATES  
AND CANADIAN PROVINCES DO NOT ALLOW:  
• LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS;  
• THE EXCLUSION OR LIMITATION OF DIRECT, INDIRECT, SPECIAL, INCIDENTAL  
OR CONSEQUENTIAL DAMAGES;  
• THE EXCLUSION OR INVALIDITY OF EXPRESS OR IMPLIED WARRANTIES IF  
THE USER CEASES TO OWN THE HUMIDIFIER;  
• THE LIMITATION OF THE REMEDIES AND RECOURSES AVAILABLE TO THE  
PURCHASER; OR THE INVALIDITY OF AN EXPRESS WARRANTY WHEN A  
PRODUCT IDENTIFIED BY BRAND NAME IS NOT USED (UNLESS SPECIFIC  
CONDITIONS ARE FULFILLED);  
SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO  
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO  
PROVINCE.  
Printed in china and Taiwan  
11  
©2010 Hunter Fan Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Music Mixer 312775G User Manual
Grizzly Tool Storage T26900 User Manual
Hamilton Beach Food Processor 70570 User Manual
Harmar Mobility Mobility Aid AL055 User Manual
Honeywell Ventilation Hood V4297S User Manual
Hotpoint Oven SC88X User Manual
HP Hewlett Packard Electronic Accessory 59308A User Manual
HP Hewlett Packard Switch BL e Class User Manual
hussman Refrigerator IGFP R3 User Manual
IBM Computer Drive 09N4153 User Manual