		 Evaporative   
					Humidifier   
					Owner’s Guide   
					Model   
					33116   
					Form# 44062-01   
					20100608   
					©2010 Hunter Fan Co.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				At A Glance   
					1 
					Warnings and Introduction   
					ReAD AND SAve THeSe INSTRUCTIONS   
					Important Safety Instructions: Read all instructions before using this humidifier.   
					• This humidifier may not work properly on an uneven surface. ALWAYS place this humidifier on a firm, level and water   
					resistant surface. ALWAYS place the humidifier at least six (6) inches away from walls and heat sources such as stoves,   
					radiators or heaters.   
					• ALWAYS place the humidifier in an area that is out of the reach of children.   
					• Before using the humidifier, extend the cord and inspect for any sign of damage. DO NOT use the product if the cord   
					has been damaged.   
					• This product has a polarized plug as a safety feature (one blade is wider than the other). This plug will fit into a polarized   
					outlet only one way. If the plug does not fully fit into the outlet, reverse the plug. If it still does not fit, contact a qualified   
					electrician. DO NOT attempt to defeat or override this feature.   
					• ALWAYS unplug and empty the humidifier when it is not in operation or while it is being cleaned.   
					• DO NOT tilt or move the humidifier while it is in operation. Never move the humidifier while there is water in the tank.   
					Empty the water tank, turn the unit off, and unplug the unit before moving.   
					• In addition to routine maintenance which may be required, this humidifier requires seasonal cleaning. Refer to and follow   
					the instructions for “Cleaning and Storage” on page 6.   
					• This unit was designed to be used with distilled and/or tap water. DO NOT add scented oils, perfumes or fragrance   
					additives to the water.   
					• Never fill the humidifier tank with hot water. Always use clean, cool tap water.   
					• The warnings and cautions in this owner’s manual cannot cover all situations, or events that may arise. Common sense   
					and caution should be used by the operator in using this device to prevent injury or accident.   
					The Hunter® evaporative Humidifier has a unique, patented design with several innovative features:   
					• Built-in Antimicrobial Properties – We use Microban® on many of the plastic parts and wick. This helps inhibit the growth   
					of bacteria, mold and fungi that may affect these parts.   
					NOTe: This product contains antimicrobial properties which are built-in to inhibit the growth of bacteria which may affect   
					the plastic and wick in the humidifier. These properties do not extend to the water, humidified air, or users. Conduct routine   
					cleaning and maintenance based upon use and individual conditions.   
					• No White Dust – The Hunter® Evaporative Humidifier produces no white dust that can settle on furniture or be inhaled.   
					NOTe: You may notice mineral deposits accumulating in the tank Tray. This is normal and does not affect performance. If   
					you would like to clean these deposits away, please see “Cleaning and Storage” on page 6.   
					3 
					©2010 Hunter Fan Company   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Using Your Humidifier   
					2 
					Initial Setup and Operation   
					Initial Setup   
					1. Remove the Hunter® Evaporative Humidifier from its packaging.   
					2. Place the humidifier on a hard, flat, water resistant surface. Always place the   
					humidifier at least six (6) inches away from walls and sources of heat.   
					3. Make sure the power/speed control is in the ‘OFF’ position.   
					Wick   
					NOTe: The power/speed control should always be off before unplugging the   
					humidifier, moving the humidifier, or refilling the water tank.   
					4. Lift the housing to ensure the wick is properly seated, resting on the bottom of   
					
					housing back on the water tray.   
					Figure 1.   
					Figure 2.   
					Figure 3.   
					Tank Handle   
					5. Grasp the water tank by the tank handle and remove it from the water tray.   
					
					6. Turn the water tank upside-down and remove the tank cap by turning counter-   
					
					7. Fill the water tank with clean, cool water and return the tank cap to its position.   
					Tighten it by turning clockwise, and return the water tank to the water tray.   
					8. Plug the humidifier’s power cord into a standard household power outlet.   
					9. Turn the power/speed control to your desired humidifier fan speed.   
					Operation   
					Off   
					Turns the unit off.   
					Low: Extends the time between refills by running the fan on low.   
					Lowest noise setting recommended for nighttime use.   
					High: Average refill rate and optimal for day use. Minimal noise   
					level.   
					To turn on or off the Niteglo™ Nitelight, just press the Niteglo™ Button on the top   
					of the unit.   
					
					If you choose to use vapor pads in your humidifier:   
					Remove 1 vapor pad from the packaging, and insert it lengthwise into the vapor   
					pad tray on the top of the exhaust grill. Vapor pads will typically last for 24 hours   
					before needing replacement.   
					Niteglo™   
					Nitelight   
					Control   
					Knob   
					Vapor Pad Tray   
					Figure 4.   
					5 
					©2010 Hunter Fan Company   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
					 
					 
					 
				Maintenance   
					3 
					Cleaning and Storage   
					Many regions have hard water with high concentrations of minerals. When water   
					evaporates from the Hunter® evaporative humidifier, minerals may be left behind.   
					These minerals can form a hard white scale which can be removed by following   
					the cleaning instructions. The frequency of cleaning due to mineral build up can   
					
					
					1. Turn the humidifier off and unplug the unit.   
					2. Lift the main housing and remove the water dispersion tray and the wick. The   
					motor is attached to the main housing. Do not place the motor near water. Do   
					not use a wet towel on the motor or motor housing as electrical shock may   
					occur.   
					Figure 5.   
					3. Replace the humidifier’s wick every 4 weeks or when it has turned brown.   
					4. Remove the water tank from the base and empty any water that is left in the   
					tank. Soak the base in a mixture of one (1) gallon of water and eight (8)   
					ounces of vinegar for 20 minutes. The base is dishwasher safe.   
					5. After soaking, wipe the base with a soft cloth or sponge to remove any   
					mineral build up. Rinse with clean water several times. If you are planning on   
					storing the humidifier, be sure the base is completely dry.   
					Figure 6.   
					6. Fill the water tank with one (1) gallon of water and eight ounces of undiluted   
					
					until all interior surfaces of the tank have been exposed to the water/vinegar   
					mixture.   
					7. Empty the tank of the water/vinegar mixture. Rinse it several times with clean   
					water and then replace the tank cap. If you are planning to store the humidifier,   
					dry it inside and out, leaving the cap off to allow the tank to completely dry.   
					Continue to clean the other parts of your humidifier.   
					
					
					Setup and Operation” on page 5 to continue use. If you are storing the   
					humidifier, make sure all parts are completely dry before reassembling, and   
					storing in a dry location.   
					6 
					44062-01 • 06/08/2010   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
					 
				Maintenance   
					3 
					Replacing the Wick   
					NOTe: The humidifier’s wick is made of paper and is NOT washable.   
					Over time, minerals in your water will build up in the humidifier’s wick, degrading   
					its ability to absorb water and reducing the humidifier’s output. Therefore, you   
					should replace the humidifier’s wick every season, depending on the hardness of   
					your water.   
					1. Turn the humidifier off and unplug the unit.   
					
					3. Grasp the humidifier wick, hold it over the base, and squeeze the water from   
					
					want to wrap the wick in a towel to keep it from dripping while you transport   
					it to disposal.   
					Figure 7.   
					4. Replace the old wick with a new Hunter humidifier wick. New wicks are   
					
					5. Ensure the wick is properly seated, resting on the bottom of the base and not   
					tilted or otherwise out of position.   
					6. Return the main housing to its position on the base. Make certain the main   
					housing is properly seated on the base.   
					7. Plug the humidifier’s power cord into a standard household power outlet and   
					turn the power/speed control to your desired setting.   
					Figure 8.   
					7 
					©2010 Hunter Fan Company   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Humidifier Assistance   
					4 
					Troubleshooting   
					Problem:   
					Excessive noise.   
					Solution:   
					1. Check the water tank to make sure it is properly seated on the base.   
					2. Check the water tank to make sure there are no bubbles when the water tank   
					is full and running. If there are bubbles, turn the unit OFF until the bubbling   
					stops. When the bubbling has stopped, set the unit to the desired speed.   
					Problem:   
					Humidifier not working.   
					Solution:   
					1. Make sure the power knob is not set to OFF and the unit is plugged into a   
					working wall outlet.   
					Problem:   
					Mineral build-up on the water tank or water tray.   
					Solution:   
					
					Problem:   
					Humidity output and water usage decreased.   
					Solution:   
					1. Check the power knob to make sure it is set to the desired speed.   
					2. Check the water tank to make sure there are no bubbles when the water tank   
					is full and running. If there are bubbles, turn the unit OFF until the bubbling   
					stops. When the bubbling has stopped, set the unit to the desired speed.   
					3. Clean any components that have mineral build-up. Refer to the section   
					
					8 
					44062-01 • 06/08/2010   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Humidifier Assistance   
					4 
					Service Parts and Support   
					Service Parts   
					Part #   
					Part Name   
					Part   
					Replace   
					89754-01-326   
					Water Tank   
					Tank Assembly   
					Cap   
					G0841-01-679   
					31951   
					1 per month or   
					as needed   
					Wick   
					99940-01-679   
					Water Tray   
					Technical Support   
					If you need any assistance with setup, operation, or parts for your new Hunter   
					Humidifier, please call us, our technical support staff is ready to help!   
					USA: 1-888-830-1326   
					Canada: 1-866-268-1936   
					Hours of operation are from 7:00 am to 7:00 pm Monday - Friday and 8:00 am   
					to 5:00 pm on Saturday, Central Time. You may also contact us over the Internet   
					at www.hunterfan.com or register your product at www.hunterfan.   
					com/register and select your product under product registration.   
					9 
					©2010 Hunter Fan Company   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Humidifier Accessories   
					Treatments   
					5 
					Model   
					Product   
					evaporative   
					Ultrasonic   
					vaporizer   
					Warm Mist   
					31955   
					Silver Ion Cartridge   
					    
					 
					31954   
					31961   
					Demineralization Cartridge   
					Vapor Steam   
					    
					31956   
					31960   
					Vapor Pads   
					    
					    
					Water Treatment Tablets   
					Notes   
					10   
					44062-01 • 06/08/2010   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Warranty   
					6 
					3 Year Guarantee   
					The Hunter Fan Company, Inc. makes the following warranty to the original   
					residential user or consumer purchaser of the evaporative humidifier:   
					If any part of the evaporative humidifier fails during the first 3 (three) years from   
					the date of purchase due to a defect in material or workmanship, we will provide   
					a replacement part free of charge.   
					If no replacement part can be provided, we will replace your humidifier.   
					IF THE ORIGINAL RESIDENTIAL USER OR CONSUMER PURCHASER CEASES   
					TO OWN THE HUMIDIFIER, THIS WARRANTY AND ANY IMPLIED WARRANTY   
					WHICH THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY   
					IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR   
					PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS   
					WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING   
					BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR   
					FITNESS FOR A PARTICULAR PURPOSE IS EXPRESSLY LIMITED TO THE PERIOD   
					OF THE EXPRESS WARRANTY SET FORTH ABOVE.   
					This warranty is voided if your humidifier is not purchased and used in the USA   
					or Canada.   
					This warranty excludes and does not cover defects, malfunctions, or failures of   
					the humidifier which were caused by repairs by persons not authorized by us,   
					use of parts, or accessories not authorized by us, mishandling, modifications, or   
					damage to the humidifier while in your possession, or unreasonable use, including   
					failure to provide reasonable and necessary maintenance. This warranty does   
					not cover humidifiers used in commercial applications. There are no express or   
					implied warranties as to commercial purchasers or users.   
					To obtain service, contact the nearest Hunter authorized service center or the   
					Hunter Fan Company Service Department, 7130 Goodlett Farms Pkwy., Suite   
					400, Memphis, TN 38016, 1-888-830-1326. You will be responsible for   
					insurance and freight or other transportation to our factory service center. We   
					will return the Vaporizer freight prepaid to you. The humidifier should be properly   
					packaged to avoid damage in transit since we will not be responsible for any   
					such damage. Proof of purchase is required when requesting warranty service.   
					The purchaser must present the sales receipt or other document that establishes   
					proof of purchase.   
					IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT,   
					INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS   
					OF THE PURCHASE PRICE OF THE VAPORIZER. YOUR SOLE REMEDY WILL BE   
					REPAIR OR REPLACEMENT AS PROVIDED ABOVE. SOME AMERICAN STATES   
					AND CANADIAN PROVINCES DO NOT ALLOW:   
					• LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS;   
					• THE EXCLUSION OR LIMITATION OF DIRECT, INDIRECT, SPECIAL, INCIDENTAL   
					OR CONSEQUENTIAL DAMAGES;   
					• THE EXCLUSION OR INVALIDITY OF EXPRESS OR IMPLIED WARRANTIES IF   
					THE USER CEASES TO OWN THE HUMIDIFIER;   
					• THE LIMITATION OF THE REMEDIES AND RECOURSES AVAILABLE TO THE   
					PURCHASER; OR THE INVALIDITY OF AN EXPRESS WARRANTY WHEN A   
					PRODUCT IDENTIFIED BY BRAND NAME IS NOT USED (UNLESS SPECIFIC   
					CONDITIONS ARE FULFILLED);   
					SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.   
					THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO   
					HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO   
					PROVINCE.   
					Printed in china and Taiwan   
					11   
					©2010 Hunter Fan Company   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 | 
Graco Heat Pump 312877C User Manual
Greenheck Fan Ventilation Hood FSDGB 211 User Manual
Haier Refrigerator RRTW User Manual
Haier TV Converter Box 25F3A User Manual
Haier Washer HW50 1003D User Manual
Hotpoint Ventilation Hood LI2JEA User Manual
HP Hewlett Packard Computer Monitor A7217A User Manual
HP Hewlett Packard Network Card AD465A User Manual
HTC Cell Phone WIZA100 User Manual
Huawei Switch S1505L User Manual