Hotpoint Ventilation Hood HXQB 98LTI User Manual

HXQB 9.8LTI  
English  
Operating Instructions  
COOKER HOOD  
Contents  
Operating Instructions,1  
Assembly.2  
Warnings,8  
Installation,10  
TBOX-GLASS controls,11  
Maintenance and care,11  
Troubleshooting,12  
After Sales Service,13  
Guarantee,14  
our  
ate y  
08448 24 24 24  
guarantee  
to activ  
Please phone us on  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1A  
Ø120mm  
Ø120mm  
Ø120  
Ø150mm  
Ø150mm  
Ø120  
Ø150  
Ø150  
1B  
Ø150mm  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
3
5
7
x6  
=
=
5
5
5
0mm  
0mm  
=
6
=
4
Ø x6  
8
mm  
x6  
6
5 mm  
x2  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
9
1
2
3
x2  
10  
11  
x2  
12  
13  
ø 120 ø 150  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
15  
16  
x2  
ø 3,5 x 9,5  
x2  
ø 3,5 x 9,5  
ø 150  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
19  
20  
18  
x2  
ø 3,5 x 9,5  
21  
A
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
• Before cleaning or servicing the unit,  
disconnect it from the mains by pulling  
the power plug or disconnecting the  
main circuit breaker.  
Warnings  
! Keep this manual for reference. If you  
sell, transfer or move the unit to another  
location, make sure to keep the manual  
with the product.  
• Alwayswearworkgloveswheninstalling  
and servicing the unit.  
• It is not intended for use by children  
or persons with sensory or mental  
disability and lack of experience or  
familiarity, except under the supervision  
or instruction of a person responsible  
for their safety.  
! Read the instructions carefully - they  
contain important installation, user and  
safety information.  
! Do not tamper with the electrical or  
mechanical equipment of the product or  
its exhaust ducts.  
• Make sure children do not play with the  
unit.  
General safety information  
• Never operate the unit without its  
• The distance between the cookware  
support surface on top of the cooking  
appliance and the lowest part of the  
cooker hood must be at least:  
65 cm if the hood is installed over a gas  
cooktop  
grease lter installed!  
• NEVER use the hood as a support,  
unless expressly instructed to do so.  
• The room must be adequately ventilated  
if the hood is used at the same time with  
other equipment burning gas or other  
fuels.  
55 cm if the hood is installed over an  
electric cooktop.  
If the installation instruction manual for  
the gas cooking appliance species a  
greater distance, this measurement  
should be taken into account.  
• Extracted air must not be conveyed into  
a duct used for exhausting combustion  
fumes from gas or other fuel-fired  
equipment.  
• The cooker hood comes with anchor  
plugs which are suitable for use with  
most walls/ceilings.  
• Observe all regulations in relation to air  
extraction.  
However, you must contact a qualied  
technician to check the suitability of the  
materials in relation to the type of wall/  
ceiling, which must be strong enough  
to support the weight of the unit.  
• NEVER cook food with an open ame  
under the hood; open flames will  
damage the lters and may cause res.  
Never do this.  
• Caution! Do not hook the unit up to  
its electrical power supply until the  
installation has been completed.  
• Always supervise frying to make sure  
the heated oil does not catch re.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
• Strictly observe all local regulations  
in relation to the technical and safety  
measures to be employed in fumes  
extraction.  
• Clean the product frequently, inside  
and out (AT LEAST ONCE A MONTH,  
and in observance of the maintenance  
instruction given in this manual).  
• Failuretoobservethehoodcleaningand  
lter cleaning/replacement instructions  
can result in res.  
• Never use the hood without its bulbs  
properly installed - electrocution hazard.  
• The manufacturer is not liable for any  
inconvenience, damage or re caused  
by the unit as a result of failure to  
observe the instructions given in this  
manual.  
• Caution! The unit's accessible parts can  
get very hot when used with cooking  
equipment.  
• This appliance can be used by children  
aged from 8 years and above and  
persons with reduced physical, sensory  
or mental capabilities or lack of  
experience and knowledge if they have  
been given supervision or instruction  
concerning use of the appliance in a  
safe way and understand the hazards  
involved. Children shall not play with  
the appliance. Cleaning and user  
maintenance shall not be made by  
children without supervision.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Ducted version  
GB  
The installation procedure is illustrated in the rst pages  
of this manual.  
The installation must be done by a qualied technician.  
The hood puries the air and expels it outdoors via an  
exhaust duct (dia. 150mm) connected to its outlet ange.  
The diameter of the exhaust tube must be equal to that of  
the outlet ange.  
Electrical hook up  
Caution! The exhaust duct is not supplied and must be  
purchased separately.  
When routed horizontally, the tube must be angled slightly  
upwards (around 10°) to enable the air to be conveyed  
outdoors more easily. If the hood is tted with charcoal  
lters, they must rst be removed.  
The mains voltage must match that given on the ratings  
label inside the hood itself. If the hood has a power plug,  
connect the hood to an easily accessible regulatory power  
socket. If it does not (direct connection to the mains), or the  
socket is not easily accessible, install a two-pole regulatory  
switch to enable total disconnection from the mains in case  
of category III overvoltage, as required by the installation  
regulations.  
Filter version  
The hood puries the air and returns it to the room. This  
version of the hood requires installation of an accessory  
active charcoal lter unit.  
This version requires an air deector, a reduction adapter  
and the charcoal lter/s. The top tube must have its air  
outlet slots uppermost.  
Caution! Always check that the mains cable is hooked  
up properly and check that it operates correctly before  
reconnecting the hood to the mains.  
Air exhaust (for ducted units)  
Connect the hood to a duct and wall exhaust hole of a  
diameter equal to that of the air outlet ange. Using a smaller  
diameter tube and exhaust hole reduces the extraction  
capacity of the hood and also increases its running noise.  
The manufacturer is not liable for any consequences of  
doing so.  
Technical data  
dia. of  
exhaust tube  
(cm)  
Height Width Depth  
Model  
(cm)  
(cm)  
(cm)  
TBOX-GLASS 90cm  
61-82  
89.9  
50  
15/12  
! Use the shortest duct required to achieve the purpose.  
! Use a duct with as few bends as possible  
Please check the plate in order to verify the total  
absorption and the light absorption  
! Avoid suddenly changing the diameter of the duct.  
! The duct must have as smooth an inner surface as  
possible.  
LED  
Risk Group 1 according to Standard EN 62471  
! The duct must be made of regulatory material.  
! Do not connect the hood to ues carrying combustion  
fumes from other equipment (boilers, chimneys, stoves,  
etc.).  
The model is in accordance with the following  
EU directives::  
• “Low voltage” Directive 2006/95/EC (12-12-2006)  
• “EMC” Directive 2004/108/EC (15-12-2004)  
• UR Reference no. 66/2014 integrating Directive  
no. 2009/125/EC.  
! Observe the instructions of the competent authorities in  
relation to the air exhaust. The air being exhausted may not  
be exhausted into a wall cavity unless the cavity in question  
is specically intended for this purpose.  
Reference standard:  
!Equip the room with air intakes to prevent the hood creating  
suction pressure in the interior (this must not exceed 0.04  
mbar).  
EN 60704-2-13:2011; EN 60704-3:2006  
EN 61591:1997; EN 61591:1997/A1:2006; EN 61591:1997/  
A2:2011; EN 61591:1997/A11:2014  
EN 50564:2011  
! The manufacturer is not liable for any consequences of  
failure to observe these instructions.  
Filter or ducted?  
! Your hood is supplied as a ducted unit.  
If you wish to use it as a lter unit, you must install the proper  
ACCESSORY KIT.  
Note: If supplied with the hood, the accessory active  
charcoal lter unit may already be installed.  
Instructions for transforming the hood from the ducted to the  
lter version are given in this manual (see “Filter version”).  
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The hood can be turned off manually by pressing the T1  
button (ON/OFF). If the timer is set, the hood turns off  
automatically when the set time runs out.  
TBOX-GLASS controls  
Models with Touch control glass (basic)  
GB  
Maintenance and care  
T1 T2 T3 T4  
T5 T6 T7 T8  
Caution! Before cleaning or servicing the unit,  
disconnect it from the mains by pulling the power plug  
or disconnecting the main circuit breaker.  
T1 motor ON/OFF  
First cleaning  
• Remove the protective lm  
• Clean with a damp sponge and a little neutral soap  
• Rinse off with a damp cloth  
When the button is pressed with the hood off, the rst speed  
is set. When the button is pressed during operation, the  
hood switches OFF.  
• Dry with a soft cloth; if the hood is stainless steel, dry  
along the metal's grain  
T2 Speed 1  
When the button is pressed the hood switches from the  
previous status to speed 1.  
Periodic cleaning  
The hood must be cleaned frequently (at least as often as  
you service the grease lter), inside and out. Use a damp  
cloth and a neutral liquid detergent with lukewarm water.  
Do not use abrasive or corrosive products.  
T3 Speed 2  
When the button is pressed the hood switches from the  
previous status to speed 2.  
Warning: Failure to observe the hood cleaning and lter  
cleaning/replacement instructions can result in res. Follow  
the instructions carefully. The manufacturer is not liable for  
any damage to the motor or res caused by incorrect care  
or failure to follow the above instructions.  
T4 Speed 3  
When the button is pressed the hood switches from the  
previous status to speed 3.  
T5 Booster  
When the button is pressed the hood switches from the  
previous status to intense speed. The setting is limited by  
time; when the time elapses the hood goes back to the speed  
set previously; when a speed button is pressed (T2, T3 or  
T4), the selected speed is set as you leave the booster mode.  
Servicing the grease lter (A)  
The grease lter retains the  
particles of grease produced  
during cooking; it must be  
cleaned at least once a month  
with a non-aggressive  
detergent, either by hand or  
with a low temperature, short  
dishwasher cycle.  
To extract the grease lter,  
T6 Timer  
A
By pressing T6 once, a timer setting can be associated to  
each speed [V](V1 – 30 min, V2 – 20 min, V3 – 10 min), after  
which the hood turns OFF automatically. The timer can be set  
for manual speeds only and not for the booster.  
pull the spring loaded handle.  
If washed in a dishwasher, the metal lter may change  
colour, but this does not affect its performance.  
T7 Antigrease and odour lter signal  
The antigrease (A) and odour (B) lters need cleaning/  
replacing after a certain number of hours of use (the latter  
for ltering hoods only).  
Servicing the charcoal lter (B)  
The charcoal lter retains unpleasant cooking odours.  
The lter saturates after a variable time, depending on the  
type of cooking and how often the grease lter is cleaned.  
The cartridge must be replaced at least once every twenty  
months.  
The time for cleaning/replacement is signalled by the  
ashing of the coloured LED associated to the lter (white  
for antigrease lters, red for odour lter).  
The LED is turned off by pressing the T7 button after  
cleaning/replacing the lters.  
This lter can NOT be washed or regenerated  
Disassembly: Remove the  
T8 lights ON/OFF  
It turns the work lights of the hood on and off.  
activated-carbon filter by  
pressing the two front levers  
which secure it to the hood.  
B
Hood conguration  
The conguration menu is accessed with the product off  
by pressing T5 and T6 for 6 seconds. T7 turns on at this  
point to indicate the type of installation through two colours  
of the LED: white for extractor installation (default), red for  
ltering installation. The installation type can be changed  
by pressing T7 cyclically with the consequent alternation  
of the LED colours.  
Hood off  
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Save energy and respect the environment  
Assembly: Secure the  
activated-carbon lter rst in  
the back using the hood's  
metal tabs and then in the  
front by pressing the two  
levers.  
GB  
• Please use the hood by setting the speed in line with the  
real extraction need; please limit the use of the “intensive  
speed” feature, if present. Using the hood in a rational  
way allows you to limit energy consumption and to avoid  
an useless waste of clean and air-conditioned air.  
• Please don’t turn on the hood light unless this is needed  
to light the cooking area.  
B
Troubleshooting  
If something does not work, make the following simple  
checks before contacting Technical Service:  
If the hood does not operate:  
Replacing the bulbs  
Disconnect the unit from the mains and remove the grease  
Check that:  
• the unit is powered up.  
• a speed has been set.  
lter.  
Caution! Make sure the bulbs are cool before touching  
them.  
If the hood is not working effectively:  
Check that:  
• the selected motor speed is sufcient to handle the  
amount of smoke and steam being produced.  
• the kitchen is adequately ventilated for the unit to take  
air in.  
1. Extract the guard by prising  
it out with a small at head  
screwdriver or something  
similar.  
2. Replace the faulty bulb.  
Use only bulbs of the  
same type (for details,  
see the technical data in  
the following manual).  
• the charcoal lter is not exhausted (lter version).  
If the hood turns off during normal operation:  
Check that:  
• the unit is powered up.  
3. Ret the guard (push it in).  
• the circuit breaker has not tripped.  
In case of faulty operation, before contacting Technical  
service, rst disconnect the machine from the mains for at  
least 5 seconds by pulling its plug, then reconnect it. If the  
fault persist, contact Technical Service.  
Replacing the lights LED  
The hood is tted with a lighting system based on LED  
technology. The LEDs ensure optimal lighting, longer life  
and lower consumption compared with traditional lights. To  
replace them please contact the assistance service.  
Electrical cable  
If the power cable is damaged, it can be replaced by the  
manufacturer or his technical service, to prevent any  
attendant risks.  
SCRAPPING  
The unit is marked for conformity with European Directive  
2012/19/EC, Waste Electrical and Electronic Equipment  
(WEEE). By ensuring that the unit is scrapped properly,  
the user contributes to safeguarding the environment and  
public health.  
The  
symbol on the product or on its accompanying  
documents indicates that the product may not be treated  
as domestic waste but must be handed over to a sorting  
centre for electrical and electronic waste. Dispose of it  
in accordance with local waste disposal regulations. For  
further information on the handling, recovery and recycling  
of this product, contact the local authority, domestic waste  
disposal service or the reseller from whom you purchased it  
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
After Sales Service  
GB  
No one is better placed to care for your Hotpoint appliance during the course of its working life  
than us - the manufacturer.  
Essential Contact Information  
Hotpoint Service  
We are the largest service team in the country offering you access to 400 skilled telephone  
advisors and 1100 fully qualied engineers on call to ensure you receive fast, reliable, local  
service.  
UK: 08448 224 224  
Republic of Ireland: 0818 313 413  
Please note: Our advisors will require the following information:  
Model number  
Serial number  
Parts & Accessories  
We supply a full range of genuine replacement parts as well as accessory products that  
protect and hygienically clean your appliance to keep it looking good and functioning  
efciently throughout its life.  
UK: 08448 225 225  
Republic of Ireland: 0818 313 413  
Appliance Registration  
We want to give you additional benets of Hotpoint ownership. To activate your FREE 5 year  
parts guarantee you must register your appliance with us.  
UK 08448 24 24 24  
Republic of Ireland: 01 230 0800  
As part of Hotpoint’s continued commitment to helping the environment, Hotpoint reserves the  
right to use quality, recycled components to keep down customer costs and minimise material  
wastage.  
Indesit Company UK Limited, Morley Way, Peterborough, PE2 9JB  
Indesit Company, Unit 49 Airways Industrial Estate, Dublin 17  
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Guarantee  
GB  
12 months Parts and Labour Guarantee  
Your appliance has the benet of our manufacturer’s guarantee, which covers the cost of  
breakdown repairs for twelve months from the date of purchase.  
This gives you the reassurance that if, within that time, your appliance is proven to be  
defective because of either workmanship or materials, we will, at our discretion, either repair  
or replace the appliance at no cost to you.  
The guarantee is subject to the following conditions:  
- The appliance has been installed and operated correctly and in accordance with our opera-  
ting and maintenance instructions.  
- The appliance is only used on the electricity or gas supply printed on the rating plate.  
- The appliance has been used for normal domestic purposes only.  
- The appliance has not been altered, serviced, maintained, dismantled or otherwise interfe-  
red with by any person not authorised by us.  
- Any repair work must be undertaken by us or our appointed agent.  
- Any parts removed during repair work or any appliance that is replaced become our proper-  
ty.  
- The appliance is used in the United Kingdom or Republic of Ireland.  
The guarantee does not cover:  
- Damage resulting from transportation, improper use, neglect or interference or as a result  
of improper installation.  
- Replacement of any consumable item or accessory. These include but are not limited to:  
plugs, cables, batteries, light bulbs, uorescent tubes and starters, covers and lters.  
- Replacement of any removable parts made of glass or plastic.  
THE GUARANTEE WILL NOT APPLY IF THE APPLIANCE HAS BEEN USED IN  
COMMERCIAL OR NON-DOMESTIC PREMISES.  
5 Year Parts Guarantee  
Hotpoint also offers you a FREE 5 year parts guarantee. This additional guarantee is  
conditional on you registering your appliance with us and the parts being tted by one of our  
authorised engineers. There will be a charge for our engineer’s time. To activate the extra  
parts warranty on your appliance, simply call our registration line on 08448 24 24 24 (ROI 01  
230 0800)  
Extended Guarantees  
We offer a selection of protection plans that enable you to fully cover yourself against the  
expense of repair bills for the life of your policy. To nd the ideal plan for you please call our  
advice line on 08448 226 226 (ROI 01 230 0233)  
Free Helpdesk Service  
We have a dedicated team who can provide free advice and assistance with your appliance if  
you experience any technical difculties within the rst 90 days of ownership.  
Simply call our Hotpoint Service Hotline on 08448 224 224 (ROI 0818 313 413) for telephone  
assistance, or, where necessary, to arrange for an engineer to call.  
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
195125388.00  
05/2014 - XEROX FABRIANO  
GB  
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grindmaster Coffeemaker P300E User Manual
Grizzly Saw G0636X User Manual
Haier Flat Panel Television P50V6 A8S User Manual
Harman Kardon Stereo Receiver AVR 120 User Manual
Honeywell Automobile Parts V4055 User Manual
Hotpoint Cooktop HW150GW User Manual
Huffy Fitness Equipment M611804 User Manual
Humminbird Fish Finder TS1 3 User Manual
IBM Computer Drive 07N4108 User Manual
Ikelite Digital Camera S5 IS User Manual