| Commercial Thermostats   Get Control. Get Honeywell.   Application Selection and   Cross-Reference Guide   7351F   CommerCial VisionPro 8000®   CommerCialPro® 7000   mUltiPro™ 7000   ZonePro®   line Volt   PneUmatiC   Fan Coil   Download from Www.Somanuals.com. All Manuals Search And Download.   T7351F   Standalone Staged Thermostat   • Keypad programming   – All configuration is done through the keypad   • Integrated humidity sensor   – Several strategies for dehumidifying   • 365-Day Schedule   – Schedule holidays throughout the year   to save energy   • Remote sensing   – Indoor, outdoor, humidity, occupancy and discharge   air sensors available for added flexibility   – Outdoor Air and Discharge Air Temperature Lockout   • Controls conventional or heat pump systems   • Flexibility allows the same thermostat to be   used on every top roof unit in the system   os number   Description   application   3 Heat/3 Cool and 2 Heat/4 Cool Conventional, or   3 Heat/2 Cool Heat Pump with 2 Auxiliary Stages,   Advanced Dehumidification and Occupancy Option   T7351 Commercial   Programmable Thermostat   T7351F2010   sensor   Compatibility   replacements   T7771A1005,   TR21,   TR21-A (averaging),   TR22,   TR23,   TR24   SZ1022,   SZ1024,   SZ1031,   SZ1033,   SZ1035,   SZ1009   All T7300s   All   All Invensys/   Robertshaw   Thermostats   All Carrier/   Totaline   Thermostats   with   Non-Q7300H   Subbases   T7351F2010   White-Rodgers   Thermostats   C7772A1012   (flush mount),   C7770A1006   (return   airduct),   C7041P2004   (button sensor)   3 Download from Www.Somanuals.com. All Manuals Search And Download.   T7351F Applications   Schools   Restaurant/Food Service   • Up to 10 holidays can be scheduled into the   Holiday scheduler, which can be programmed to   handle multiple days per holiday event, can program   closed days during the summer, or spring break   and can be programmed for specific calendar events.   • Dehumidification features can be used to control   dew points in buildings and can be deployed where   moisture is an issue, such as around school pools or   in humid locations.   • Commercial Algorithm provides the best comfort control   to react to the constantly changing food service and   restaurant environments, reacting quickly to changing   load demands via fast-sensing time constants.   • Remote Sensing configuration options allow the use of   commercial 20K ohm and 10K ohm sensors to create   a 20K ohm averaging network, a good solution for food   service locations that have high load demands.   • Economizer function allows restaurants to meet   ventilation requirements and is also important to balance   the air intake of the restaurant. Restaurants that are not   properly balanced do not achieve good comfort control   as they draw in unconditioned air.   • Temporary Override can be configured from 1 to 8   hours to allow override from unoccupied schedule   to an occupied schedule as well as for classrooms   that are only used for parts of the week or just   occasionally used.   • Control Algorithm is the best available for heating   and cooling large spaces, such as gymnasiums or   auditoriums, quickly and accurately. The algorithm   is specifically tuned for commercial equipment and   has a short sensor time constant that can react   quickly to demand changes.   Churches/Public Worship   • T7351F Wall Modules, including the T7771, TR22, TR23   and TR24 models allow for setpoint-only adjustment   with range stops, temporary override control, or a   combination of both to provide the end-users with flexibility   to provide optimal comfort during occupied events.   Healthcare and Gym Facilities   • Dehumidification features are ideal for controlling   high-moisture areas.   Retail   • Customizable Recovery Ramp feature guarantees the   exact temperature specified when the store opens,   ensuring customer and staff comfort.   • Easy-to-use Holiday Scheduler.   4 Download from Www.Somanuals.com. All Manuals Search And Download.   Office Building Zones   Heat Pumps   • The T7351F is one of the only Honeywell thermostats that   integrate with occupancy sensors for office zones that are   normally unoccupied or partially occupied.   • Outdoor Air Sensor automatically turns off heat pump   equipment in cold climates. The T7351F is the only   Honeywell thermostat that uses both an outdoor air   sensor and indoor sensors/wall modules for heat pump   control applications.   • T7351F Wall Modules, including the T7771, TR22, TR23 and   TR24 models allow for setpoint-only adjustment with range   stops, temporary override control or a combination of both to   provide the end-users with flexibility to provide optimal   comfort during occupied events.   Equipment Protection   • Discharge Air Sensor detects abnormally high or low   discharge air temperatures and shuts down equipment   if limits are exceeded.   • Customizable Recovery Ramp feature guarantees the   exact temperature specified when the office opens.   os number   Benefit   Energy Savings, Comfort, Fresh Air, Dehumidification   T7351F2010   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Commercial   ® VisionPRO 8000   Programmable Touchscreen Thermostat   • Touchscreen user interface   – The sleek design, menu-driven programming   and large touchscreen display are all here   • Saves energy   – Effortless programming helps your customers   save up to 33% off their energy bill1   • Meets commercial building codes   – Pre-occupancy Purge, Economizer Output and   Override Limits meet all fresh air and override   limitation requirements   – Qualifies for utility rebates2   – Title 24/IECC/ASHRAE codes   • Multiple lockout levels   – Save energy and money by preventing   unauthorized setting changes   • Compatible with auxiliary commercial devices   – Commercial sensors   – Economizers   • Commercial comfort   – Commercial Algorithm, configurable recovery ramps   and temporary override button allow users to control   at setpoint and guarantee a comfortable environment   1 If used as directed. Savings may vary depending on geographic   region and usage.   2 Where applicable.   os number   Description   application   Commercial VisionPRO® 8000   Programmable Thermostat   – 2 Heat/2 Cool Conventional   – 3 Heat/2 Cool Heat Pump   TB8220U1003   sensor   Compatibility   replacements   TR21,   TR21-A   P374-2100,   P374-2200,   P374-2300,   T7300 with   (averaging),   C7772A1012   (flush mount),   C7770A1006   (return air   duct),   C7041P2004   (button sensor)   Q7300A2016,   Q7300A2008,   Q7300C2004   and   Q7300C2012   Subbase   9800 Series,   9700i Series,   300 Series   IF90 Series,   IF80 Series   33S250-01,   TB8220U1003   33CS220-01,   33CS071-01,   33CSSP2-WC,   33CSSN2-WC   6 Download from Www.Somanuals.com. All Manuals Search And Download.   ® CommercialPRO 7000   Thermostat   • Large, easy-to-read display   – Screen size is more than double competitive   thermostats in this class, allowing for more   information to be displayed on the easy-to-view   backlit display   • Saves energy   – Easy-to-use, menu-driven programming helps   your customers save up to 33% off energy bills1   • Meets commercial building codes   – Pre-occupancy Purge, Economizer Output, and   Override Limits meet all fresh air and override   limitation requirements   – Qualifies for utility rebates2   – Title 24/IECC/ASHRAE codes   • Multiple lockout levels   – Save energy and money by preventing   unauthorized setting changes   • Compatible with auxiliary commercial devices   – Commercial sensors   – Economizers   • Commercial comfort   – Commercial Algorithm, configurable recovery ramps   and temporary override button allow users to control   at setpoint and guarantee a comfortable environment   1 If used as directed. Savings may vary depending on geographic   region and usage.   2 Where applicable.   os number   Description   application   CommercialPRO® 7000   Programmable Thermostat   – 2 Heat/2 Cool Conventional   – 3 Heat/2 Cool Heat Pump   TB7220U1012   sensor   Compatibility   replacements   TR21,   TR21-A   P374-2100,   P374-2200,   P374-2300,   T7300 with   (averaging),   C7772A1012   (flush mount),   C7770A1006   (return air   duct),   C7041P2004   (button sensor)   Q7300A2016,   Q7300A2008,   Q7300C2004   and   9800 Series,   9700i Series,   300 Series   IF90 Series,   IF80 Series   33S250-01,   TB7220U1012   33CS220-01,   33CS071-01,   33CSSP2-WC,   33CSSN2-WC   Q7300C2012   7 Download from Www.Somanuals.com. All Manuals Search And Download.   MultiPRO™ 7000   Multispeed and Multipurpose Thermostat   • Large, easy-to-read display   – Screen size is more than double competitive   thermostats in this class, allowing for more information   to be displayed on the easy-to-view backlit display.   • Programmable or non-programmable modes   • Saves energy   – Effortless programming helps your customers   save up to 33% off their energy bill1   – Remote setback input for occupancy sensors   or timeclocks   – VersaSpeed™ fan ramping algorithm and auto fan   reset algorithm (fan coil and PTAC applications)   • Multiple lockout levels   – Save energy and money by preventing   unauthorized setting changes   • Compatible with commercial sensors   • Commercial comfort   – Commercial Algorithm, configurable recovery ramps   and temporary override button allow users to control   at setpoint and guarantee a comfortable environment   • Multispeed and Multipurpose   – 1 Heat/1 Cool Conventional (single speed)   – 2 Heat/1 Cool Heat Pump (single speed)   – 2 Heat/1 Cool PTAC (2 speeds)   – 2 or 4-pipe Fan Coil (3 speeds)   1 If used as directed. Savings may vary depending on geographic   region and usage.   os number   Description   application   1 Heat/1 Cool Conventional,   MultiPRO™ Multispeed and   Multipurpose Thermostat   2 Heat/1 Cool Heat Pump,   2 Heat/1 Cool PTAC Systems and   2 or 4-pipe Fan Coil   TB7100A1000   sensor   Compatibility   replacements   IF90-371,   IF96-344,   TR21,   TR21-A   C7772A1012   (flush mount),   C7770A1006   (return air   duct),   C7041P2004   (button sensor)   IF97-371,   IF80-224,   IF80-241,   IF80-261,   IF86-244,   IF87-251,   IF82-261,   IF89-211   97012,   9610,   9700i,   300-224,   300-225,   300-226,   T8574B2016,   P274-0100,   P274-1100,   P374-0200,   P374-0300   DFC-20YU6585F,   DPFC-024U2F,   DPFC-024K2F,   T8575B2007,   T8575C2005,   T8575D2003   TB7100A1000   TDMS24-AH22CB   8 Download from Www.Somanuals.com. All Manuals Search And Download.   Private Label Program   AssociateYour Company Name   WithThe Honeywell Brand   • Give your customers the quality and reliability of a   Honeywell thermostat   • Let customers know who to call for future HVAC needs   • Up to three full lines of personalization — imprinted   directly on the thermostat cover   • Low minimum order quantities — starting at just 48 units   • No annual volume commitments   Acme Heat & Cool   1-800-222-2222   • Fastest turn-time in the industry — imprint approval in 5   days or less, all orders shipped in 10 days or less*   * Provided all program conditions are met.   Based on product availability.   Program Details   MIN. ORDER QUANTITY   ORDER PROCESS*   IMPRINT FEE   Initial Orders   Re-Orders   48 Units   Through Web site customer.honeywell.com   Through Web site customer.honeywell.com   None   None   24 Units   Web Setup   Distributor Instructions   Before you begin creating a   private label, set up a unique   product part number(s) for your   customer in your system.   • The part number(s) that you   assign must be unique to each   customer and each product.   • Maximum of 18 characters per   distributor part number. Part   numbers must be upper case   with no spaces. (For example:   TB8220CLIMATRON).   Free setup on all orders placed through customer.honeywell.com   Log on to customer.honeywell.com using your Distributor Account Number and password* and   click on the “Private Label Program” link in the right-hand column of the screen. Click on the   “Create New Label” link on the secondary menu bar at the top of the screen.   Step 1: Create a Label   • Select the font type.   • Type in your customer’s information exactly as they would like it to appear on their thermostats.   • Preview and submit your label when complete.   Step 2: Part Number Setup   • Select the Honeywell thermostat part numbers from the drop-down menu (the description will   automatically populate).   • Do not use Honeywell part   number(s) for your customer   part numbers. We suggest   using a variation such as the   example above.   • Enter in your customer’s unique part number(s).   • Submit for approval and print a copy for your records.   • You will receive approval from Honeywell within 5 days of submittal that part number(s) have been   set up and product is available to order.   • You must use your distributor   part number when ordering   private label units.   Step 3: Place Your Order   • Place an order (using your customer’s unique part number) after receiving both e-mail confirmations   from Honeywell that your label and part number(s) have been approved.   *Contact Honeywell customer care with any questions relating to logging on to customer.honeywell.com.   ALL PRIVATE LABEL ORDERS REQUIRE A MINIMUM INITIAL ORDER QUANTITY OF 48 UNITS. Mix/match is allowed to reach 48 minimum   initial order quantity, but must contain a minimum of 24 units per part number. Mix and match products include Commercial VisionPRO®,   VisionPRO®, CommercialPRO®, FocusPRO and PRO model families. Please refer to customer.honeywell.com for full OS numbers. Orders must   be placed in case quantities of 12. Re-order quantity is 24 units (must be the same part number). Private label orders are non-cancelable.   All private label orders will require a 10-day lead time — from the time submitted label artwork is approved and a purchase order is received from the Wholesaler/Distributor to the time   the private label product is shipped by Honeywell. All private label orders will be shipped directly to the Wholesaler/Distributor. Honeywell will not hold any inventory on private label product.   Any change in the label will be treated as a new label creation and the approval process must be followed in total. Coordination will be required for the transition, including purchasing   existing stock of customer parts. All private label requests must conform to the standards set by Honeywell. Honeywell reserves the right to deny any private label request as its own discretion.   Any inventory in the channel (in the factory, in the warehouse or in transit) is the responsibility of the Wholesaler/Distributor. Honeywell will not be liable for any inventory in the channel.   By ordering private label products, you are agreeing to the terms stated in this program description. Honeywell reserves the right to change or cancel this program without notice.   9 Download from Www.Somanuals.com. All Manuals Search And Download.   Commercial VisionPRO® 8000, Commercial PRO® 7000 And Multi   After-Hours Control in Office Buildings   • The Override button can be configured for a length of   time (1, 2, 3, 4 hours) and can be configured for an exact   override setpoint through the use of the lockout level   set-up and the temperature range stop setup. A user may   override to an exact setpoint or be given a setpoint range   to choose from.   Condominiums/Hotels   • Honeywell’s MultiPRO™ thermostat uses the patent   pending VersaSpeed™ fan ramping algorithm to give   multiunit facilities such as hotels, condos, dorms and   retirement facilities more control and additional savings   through the elimination of unnecessary energy use.   • The fan coil and PTAC applications on the MultiPRO™   make it a perfect thermostat for hotels or condominiums.   (See our SuitePRO™ thermostat, too)   • Provides comfort during after-hours occupancy while   maintaining energy savings after the tenant leaves   the building.   Economizer Integration   Schools – Individual Zone Control   • Cancel Period button allows thermostat to remain in   permanent unoccupied mode to provide energy savings   for school classrooms not being used.   • Compatible with Honeywell Economizer controllers, which   generate free cooling if appropriate outside air and/or   humidity conditions exist. (Not available on MultiPRO™)   • Thermostats are integrated with economizers to maintain   minimum ventilation requirements of the building   during occupied periods. During unoccupied periods,   thermostats can override the economizer to fully close the   damper, thereby eliminating air infiltration into the building   to maximize energy savings.   • Teachers wanting to use a classroom press the Override   button and the thermostat enters the occupied period   providing the necessary comfort.   • The Override button can be configured for a length of   time (1, 2, 3, 4 hours) and can be configured for an exact   override setpoint through the use of the lockout level   setup and the temperature range stop setup. A user may   override to an exact setpoint or be given a setpoint range   to choose from.   os number   Benefit   Energy Savings, Comfort, Fresh Air   TB8220U1003   • During long holidays or during summer vacation, the   thermostat can be programmed with the Holiday button to   provide the greatest amount of energy savings.   Energy Savings, Comfort, Fresh Air   TB7220U1012   Energy Savings, Comfort and Versatility   TB7100A1000   Restaurant/Food Service Control   • Honeywell’s Commercial Algorithm provides the best   comfort control to react to the challenging environments   of food service and restaurant environments. The   commercial algorithm is tuned to provide the tightest   comfort control and react quickly to changing load   demands via fast-sensing time constants.   • Economizer function allows restaurants to meet the   appropriate ventilation requirements and is also important   to balance the air intake of the restaurant. Restaurants   that are not properly balanced do not achieve good   comfort control as they draw in unconditioned air.   • Remote sensing configuration options allow the use of   commercial 10K ohm and 20K ohm sensors to provide   any remote sensing combination (1 to 9+ sensors) to   create an averaging network.   14   Download from Www.Somanuals.com. All Manuals Search And Download.   iPRO™ Applications   Remote Sensing   Unit Vent   Can be configured using Honeywell’s line of 10K ohm and   • Can be programmed to control ASHRAE Cycle 1 unit vent   applications.   20K ohm commercial sensors, supporting the following   applications that residential thermostats don’t:   • Temperature Averaging Networks   • Unit vent outside-air damper can be programmed through   the Economizer feature. When the unit vent is on and   occupied, the thermostat will enable the economizer   relay to keep the outside air damper at the maximum   percentage opening. Only maximum percentage   opening is available; the thermostat will not modulate   the damper. When the unit vent is unoccupied, the   thermostat will close the damper.   Because commercial thermostats can be configured   to a 20K ohm network, temperature average networks   of anywhere from 1 to 9+ sensors can be deployed.   Combinations of 10K ohm and 20K ohm sensors are   use to create the averaging network. The most popular   sensors are the TR21 and TR21-A (averaging) 10K sensor   and the TR21 and TR21-A 20K sensor.   • Range Stop feature can be configured to program a low   limit setpoint to prevent equipment damage from freezing.   sUBBase   tr21   Commercial Codes   • Comply with commercial building codes and meet the most   rigorous standard, California’s Title 24.   • No hold button is available, so the thermostat remains   in permanent schedule.   tr21-a   tr21   • Override button allows the tenant to override an   unoccupied mode for up to 4 hours and can be configured   for an exact override setpoint. Depending on the partial   lockout level deployed, a user may override to an exact   setpoint or be given a setpoint range to choose from.   • Pre-Occupancy Purge and Economizer functions allow   the building owner to meet all HVAC ventilation codes for   commercial buildings.   tHe tr21-a is a 10K oHm sensor   • Room Temperature Control   Performed via a sensing network using the following   sensors:   – Wall Sensors: TR21-A (10K) for averaging only,   TR21 (20K), C7189U1005 (10K)   Lighting Load Reduction (TOD)   • Commercial buildings are frequently automated to turn off   lighting loads. Lighting loads can use even more energy   than HVAC systems in commercial buildings, and 79%   of commercial buildings have off-hours lighting load   reduction control. By using the time-of-day relay (TOD)   in conjunction with a lighting control system, users can   automate their lighting loads. (Not available on MultiPRO™)   – Flush Mount Sensors: C7772A1012 (20K)   – Button Sensors: C7041P (20K)   • Duct Return Temperature Control   Performed using the following 20K sensors:   C7041B/C7041C/C7770A/C7041J   15   Download from Www.Somanuals.com. All Manuals Search And Download.   ZonePRO®   Commercial Modulating Zoning Thermostat   • Good looks   – Many thermostats used for this application look very   outdated, but the ZonePRO® is modern and attractive   • Price   – Very cost-effective alternative to an expensive   networked zoning system   • Flexibility   – Has more features and fits more applications   than other thermostats in this market (setback   input, additional analog and triac output on   the B models)   – Duct sensor and remote sensor capabilities   are standard, allowing flexibility to do room   temperature sensing, discharge air control,   sensor averaging   • Easy to install   – Easy to wire   – Easy to program the configuration code   – Power output graph helps the installer   understand if the actuator is operating properly   • Saves energy   – Override button and night setback   – Range stop temperature limits   – System control modes such as fresh air control   and limited cooling modes   User   interface   Universal   applications method   Power   Compatible   actuators   Compatible   Valves   sensors and   accessories   os number   schedule options   output type   Features and Functions   replaces   Floating,   Single Output   TB6980A1007   TB6980B1006   TB7980A1006   T6984A1059   VC6930,   VC6934,   VC6936,   M6410,   M6435   R841 Series of   electrome-   ML6984A1006,   ML6420,   ML6161B2024,   MN6105A1011   Auto   Changeover,   Discharge   Air   Temperature,   Return   24VAC   Air   chanical relays,   50014157-001   air duct sensor,   50014156-002   space sensor,   ST6008A1003   and   ST7009A1003   time clocks,   209651A   Floating, Multi   Output (extra   analog and   T6984D1046,   T6984E1043   digital output)   Non-   Programmable   with Night   Setback input   Yes   (indoor,   outdoor,   supply)   Analog (0-10V   or 2-10V),   Single Output   Yes   Digital   Yes Yes Yes Yes   Yes   T7984A1057,   T7984A1065   Temperature,   Room   VC7930,   VC7934,   VC7936,   M7410,   M7435   ML7984A4009,   ML7420,   ML7161A2008,   MN7505A2001   Analog (0-10V Temperature,   or 2-10V),   Multi Output   (extra analog   and digital   output)   Limited   Cooling   wall plate,   D640 and D690   dampers   T7984B1055,   T7984C1053   TB7980B1005   12   Download from Www.Somanuals.com. All Manuals Search And Download.   ZonePRO® Applications   Stand-AloneVAV Pressure   Dependent (VVT Zoning) Control   • Typical building applications include zoning for office   buildings, airports, strip malls and multi-tenant facilities   that have multiple terminal zones that run off of a single   air-handler.   Hydronic Control &   Modulating Heating   • Can be used for modulating hydronic heating or   cooling applications.   • Other common applications include radiant panel   heaters, cabinet heaters, fin-tube radiators and other   electric or hydronic re-heat applications.   • Thermostats provide modulating control (floating or   analog) for each zone.   • Can be configured for cool only, heat only or   auto changeover. Up to 2 re-heat outputs are available   if the discharge air from the air handler needs to be   heated at the zone (B models).   • Remote sensors are compatible with all ZonePRO   models if remote room sensing or return air temperature   sensing is desired.   • May also be used at the air handler to control the   temperature of the fresh air supply or provide limited   cooling using outdoor air when appropriate.   • All ZonePRO thermostats come with energy-saving   range stop and night setback configurability.   tB7980B1005: Cooling only Pressure Dependent VaV Zone reheat and electric Baseboard Heat   Supply Air Temperature Sensor   Modulating Damper   Actuator   Hot Water   Coil   841   lay   Electric Baseboard Heat   13   Download from Www.Somanuals.com. All Manuals Search And Download.   Other Thermostats   Line Volt   • Simple interface for control of line voltage heaters   – Easy for occupants to read and change   setpoints   T651A3018 — Degree F scale, for heavy-duty line   voltage heating systems   T651A3026 — Degree C scale, for heavy-duty line   voltage heating systems   T451A3005 — Degree F scale, for light-duty line   voltage heating systems   Pneumatic   • Large replacement market   – Large installed base, popular proven design for   pneumatic systems   Go to customer.honeywell.com for a list   of all model numbers and accessories.   14   Download from Www.Somanuals.com. All Manuals Search And Download.   SuitePRO™ Digital Fan Coil   • Energy savings, aesthetic appeal, and easy to install   TB6575A1000— 2/4 pipe 120/240V fan coil thermostat   with manual or auto changeover   TB6575B1000— 2 pipe only 120/240V fan coil   thermostat with manual or seasonal changeover   TB8575A1000— 2/4 pipe 24V fan coil thermostat with   manual or auto changeover   Electromechanical   Fan Coil   • Popular for the replacement market   – Large installed base, popular proven   mechanical design   T4039B1008 — 2/4 pipe 24 V electromechanical   fan coil thermostat   T4039M1004 — 2/4 pipe 24 V electromechanical   fan coil thermostat with positive off   T4039M1103 — 2/4 pipe 24 V electromechanical   fan coil thermostat with positive off (white color)   with automatic changeover and fan auto switch   T6169C4015 — 2 pipe fan coil, manual or auto   changeover   T6169B4017 — 2 pipe fan coil, manual heat-cool   changeover, no fan switching   15   Download from Www.Somanuals.com. All Manuals Search And Download.   Honeywell Thermostat Cross-Reference Chart   User   Power   Method   Model   Schedule Options   Application   Feat u   Interface   3 Heat/   365-   Day   Soft   Keys   3 Cool or 3 Heat/   2 Heat/ 2 Cool   4 Cool   T7351F2010   Yes   Yes   Yes   No   24 Vac   Yes   Yes Yes No   Conventional/   Heat Pump   24 Vac   or   Battery   Yes   (Cumulative)   Touch-   screen   2 Heat/ 3 Heat/   TB8220U1003 7-Day Yes   Yes   No   Yes   Yes Yes No   2 Cool   2 Cool   Commercial   VisionPRO® 8000   24 Vac   or   Battery   Yes   (Cumulative)   Soft   Keys   2 Heat/ 3 Heat/   B7220U1012 7-Day Yes   Yes   No   Yes   Yes Yes No   2 Cool   2 Cool   CommercialPRO 7000   24 Vac   or   Battery   Yes   (Cumulative)   Soft   Keys   1 Heat/ 2 Heat/   2 or 2 Heat/   4-pipe 1 Cool   B7100A1000 7-Day Yes   Yes   No   Yes   Yes Yes No   1 Cool   1 Cool   MultilPRO™   16   Download from Www.Somanuals.com. All Manuals Search And Download.   Display   Information   Sensor   Compatibility   ures and Functions   Warranty   Replacements   T7771A1005,   TR21,   TR21-A   (averaging),   TR22,   SZ1022,   SZ1024,   SZ1031,   SZ1033,   SZ1035,   SZ1009   Yes (Indoor,   Outdoor,   Yes Discharge, 4.2 sq. in. No Yes No   All T7300s   with non-   Q7300H   All   White-   Rodgers   Thermostats   All Invensys/   Robertshaw   Thermostats   All Carrier/   Totaline   Thermostats   TR23,   TR24,   Yes   (4)   Yes   1 Year   Humidity,   Occupancy)   C7772A1012   (flush mount),   C7770A1006   (return airduct),   C7041P2004   (button sensor)   subbases   TR21,   TR21-A   P374-2100,   P374-2200,   T7300 with   Q7300A2016,   Q7300A2008,   Q7300C2004   and   (averaging),   C7772A1012   (flush mount),   C7770A1006   (return air duct),   C7041P2004   (button sensor)   P374-2300,   Yes   (Indoor or   Outdoor)   9800 series,   9700i series,   300 series   Yes   (4)   1F90 series,   1F80 series   33CS250-01,   33CS220-01,   33CS071-01,   33CSSP2-WC,   33CSSN2-WC   Yes   No   10 sq. in. Yes Yes Yes   5 Years   Q7300C2012   subbase   TR21,   TR21-A   P374-2100,   P374-2200,   T7300 with   Q7300A2016,   Q7300A2008,   Q7300C2004   and   (averaging),   C7772A1012   (flush mount),   C7770A1006   (return air duct),   C7041P2004   (button sensor)   P374-2300,   Yes   (Indoor or   Outdoor)   9800 series,   9700i series,   300 series   Yes   (4)   1F90 series,   1F80 series   33CS250-01,   33CS220-01,   33CS071-01,   33CSSP2-WC,   33CSSN2-WC   Yes   No   4 sq. in. Yes Yes Yes   2 Years   Q7300C2012   subbase   IF90-371,   IF96-344,   IF97-371,   IF80-224,   IF80-241,   IF80-261,   IF86-244,   IF87-251,   IF82-261,   IF89-211   TR21,   TR21-A   97012,   9610,   9700i,   300-224,   300-225,   300-226,   (averaging),   C7772A1012   (flush mount),   C7770A1006   (return air duct),   C7041P2004   (button sensor)   T8574B2016,   T8575B2007,   T8575C2005,   T8575D2003   P274-0100,   P274-1100,   P374-0200,   P374-0300   Yes   (Indoor or   Occupancy)   Yes   (5)   SZ1-61,   SZ1062   No   No   4 sq. in. Yes Yes Yes   2 Years   17   Download from Www.Somanuals.com. All Manuals Search And Download.   Accessories   Remote Room Temperature and Discharge   Air Sensors   • Full line of remote wall sensors   • Gives user the option to have setpoint knobs/buttons, override button or sensor only   • Flush mount versions are available for high traffic areas where protruding objects   would get broken   C7189U1005 — 10K sensor   C7041D — 20K immersion sensor   C7041K — 20K strap-on sensor   C7041P — 20K button sensor   C7041P   C7772A1012 —20K flush mount sensor   C7041B — 20K duct mount sensor   C7041C — 20K duct mount sensor   C7770A — 20K duct mount sensor   Remote Sensors Compatible with the T7351F   Honeywell has a full line of remote sensors that are compatible with the T7351F.   remote room sensors   TR21   TR21-A   20K   10K Averaging   C7041C   C7772A1012   TR22   TR23   TR24   20K, ±5° Setpoint Adj.   20K, ±5° Setpoint Adj. & Bypass   20K, Bypass   T7771A1005   C7770A1006   C7041P2004   C7189U1005   C7772A1012   10K/20K, ±3° Setpoint Adj. & Bypass   Return Air Duct   Button   Remote Indoor   20K Flush Mount Sensor   remote Humidity sensors   H7625A1008   H7625B1006   H7635A1006   H7635B1004   H7635C1002   H7655A1001   H7655B1009   2% Accuracy Wall Mount   2% Accuracy Duct Mount   3% Accuracy Wall Mount   3% Accuracy Duct Mount   3% Accuracy Outdoor   5% Accuracy Wall Mount - Humidity only   5% Accuracy Duct Mount   T7771A1005 Remote   TR22   Remote Wall Senor   Wall Senor   Discharge air sensors   C7041B2005   20K Discharge Air, 5" Duct Insertion   C7041B2013   20K Discharge Air, 12" Duct Insertion   outdoor air sensors   C7031G2014   C7170A1002   C7089U1006   3K Platinum Outdoor Air Sensor   3K Platinum Outdoor Air Sensor   C7089 Remote Outdoor Sensor   C7031G2014   3K Platinum Outdoor   Air Senor   Economizer   remote Pipe sensor   PS20   20K Analog Pipe   Economizers Compatible with the T7351F, CVP and CP   Honeywell has a range of economizer controls that are compatible with the T7351F, Commercial VisionPRO and Commercial PRO   thermostats. These economizers save energy by bringing in cool outdoor air when there is a need for cooling and some models   also adjust outdoor damper position based on indoor air quality (CO2) for demand control ventilation.   • W7459, W7210 (economizer only)   • W7212, W7213, W7214 (economizer and Demand Control Ventilation)   The Demand Control Ventilation economizers listed above have the latest features, including indoor air quality maximum output,   night setback terminal and they drive a 2– to 10–volt motor.   18   Download from Www.Somanuals.com. All Manuals Search And Download.   Notes   19   Download from Www.Somanuals.com. All Manuals Search And Download.   Learn More   For more information on Honeywell   Commercial Thermostats, contact   your local Honeywell authorized   distributor, call 1-763-954-6464 or   visit customer.honeywell.com.   Automation and Control Solutions   In the U.S.:   Honeywell   1985 Douglas Drive North   Golden Valley, MN 55422-3992   In Canada:   Honeywell Limited   35 Dynamic Drive   Toronto, Ontario M1V 4Z9   In Latin America:   Honeywell   9315 N.W. 112th Avenue   Miami, FL 33178   63-9620GW   September 2008   © 2008 Honeywell International Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   |