Granit 1980i
Industrial Full Range Area-Imaging Scanner
Quick Start Guide
查看繁体版请登陆 www.honeywellaidc.com
GRNT1980-QS Rev A
12/14
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Scanner
When connecting the scanner, make sure the cable is pushed tightly
into the scanner. Loosen the locking plate and slide it over the base
of the cable connector to lock the cable in place. Tighten the screw.
USB:
Download from Www.Somanuals.com. All Manuals Search And Download.
RS232 Serial Port:
Download from Www.Somanuals.com. All Manuals Search And Download.
Reading Techniques
Near Distance Scanning
Use the red lighting and center the box over
the bar code when scanning at a near
distance (less than 11.8 inches / 30 cm).
The laser aimer will be to the right of the
center of the bar code.
Far Distance Scanning
Use the laser aimer and aim at the center of the
bar code when scanning at a far distance (up to 50
feet / 15.2 meters).
When scanning at far distances the red lighting
may not be apparent.
Note: If the bar code is highly reflective (e.g., laminated), you may
need to tilt the scanner at an angle so the bar code can be
scanned.
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Product Defaults
The following bar code resets all standard product default settings.
Standard Product Defaults
USB Serial
Scan the following code to program the scanner to emulate a regular
RS232-based COM Port. If you are using a Microsoft® Windows®
PC, you will need to download a driver from the Honeywell website
(www.honeywellaidc.com). The driver will use the next available
COM Port number. Apple® Macintosh computers recognize the
scanner as a USB CDC class device and automatically use a class
driver.
USB Serial
Note: No extra configuration (e.g., baud rate) is necessary.
USB PC Keyboard
Scan the following code to program the scanner for a USB PC
Keyboard.
USB PC Keyboard
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Country
Scan the Program Keyboard Country bar code below, then scan
the numeric bar code(s) from page 12, then the Save bar code to
program the keyboard for your country. As a general rule, the
following characters are not supported by the scanner for countries
other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~.
Program Keyboard Country
Country Code
Belgium
Scan Country Code
Scan
1
8
2
3
4
7
Italy
5
Denmark
Norway
9
Finland
Spain
10
6
France
Switzerland
USA (Default)
Germany/Austria
Great Britain
0
Save
Note: For a complete list of country codes, see the User’s Guide for
your product at our website, www.honeywellaidc.com.
Download from Www.Somanuals.com. All Manuals Search And Download.
Aimer Delay
Set the time between when the trigger is pulled, turning the laser
aimer on, and when the picture is taken. During the delay time, the
laser aimer appears so you can find the bar code. When the delay is
over the LEDs turn on and the scanner reads the bar code. This can
be helpful when reading at far distances.
Aimer Delay 1000 ms
Aimer Delay Off
(Default)
Note: For more options, see the User’s Guide for your product at our
website, www.honeywellaidc.com.
Download from Www.Somanuals.com. All Manuals Search And Download.
Suffix
If you want a carriage return after the bar code, scan the Add CR
Suffix bar code. To add a tab after the bar code, scan the Add Tab
Suffix bar code. Otherwise, scan the Remove Suffix bar code to
remove the suffixes.
Add CR Suffix
Add Tab Suffix
Remove Suffix
Add Code ID Prefix to all Symbologies
Scan the following bar code if you wish to add a Code ID prefix to all
symbologies at once.
Add Code ID Prefix To All Symbologies
(Temporary)
Note: For a complete list of Code IDs, see the User’s Guide for your
product at our website, www.honeywellaidc.com.
Download from Www.Somanuals.com. All Manuals Search And Download.
Function Code Transmit
When this selection is enabled and function codes are contained
within the scanned data, the scanner transmits the function code to
the terminal. Charts of these function codes are provided in your
User’s Guide.
Enable
(Default)
Disable
Download from Www.Somanuals.com. All Manuals Search And Download.
Data Format Editor Instructions
The following are abbreviated instructions for entering a data format.
For complete instructions refer to your User’s Guide, available at our
website, www.honeywellaidc.com.
1. Scan the Enter Data Format bar code.
2. Primary/Alternate Format: scan 0 for Primary Format
3. Terminal Type: scan 099 for any terminal type
4. Code I.D.: scan 99 for any bar code type
5. Length: scan 9999 for any length bar code.
6. Editor commands: use the Programming Chart that follows.
7. Scan Save to save your entries.
Enter Data Format
Clear All Data Formats
Save
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Chart
0
1
2
4
6
3
5
7
Download from Www.Somanuals.com. All Manuals Search And Download.
8
9
A
C
E
B
D
F
Save
Download from Www.Somanuals.com. All Manuals Search And Download.
EZConfig-Scanning
To access additional features for the scanner use EZConfig-
Scanning, an online configuration software tool, available from our
website at www.honeywellaidc.com.
Technical Assistance
Contact information for technical support, product service, and repair
Limited Warranty
product’s warranty information.
Patents
User Documentation
For localized versions of this document, and to download the User’s
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in
specifications and other information contained in this document without prior
notice, and the reader should in all cases consult HII to determine whether
any such changes have been made. The information in this publication does
not represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained
herein; nor for incidental or consequential damages resulting from the
furnishing, performance, or use of this material.
This document contains proprietary information that is protected by copyright.
All rights are reserved. No part of this document may be photocopied,
reproduced, or translated into another language without the prior written
consent of HII.
2015 Honeywell International Inc. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
Web Address: www.honeywellaidc.com
Download from Www.Somanuals.com. All Manuals Search And Download.
|