Honeywell Scanner 1980i User Manual

Granit 1980i  
Industrial Full Range Area-Imaging Scanner  
Quick Start Guide  
Aller à www.honeywellaidc.com pour le français.  
Vai a www.honeywellaidc.com per l'italiano.  
Gehe zu www.honeywellaidc.com für Deutsch.  
Ir a www.honeywellaidc.com para español.  
Para Português, acesse www.honeywellaidc.com.br.  
Перейти на русскоязычный сайт www.honeywellaidc.com.  
Pro češtinu jdi na www.honeywellaidc.com.  
Pre slovenčinu choď na www.honeywellaidc.com.  
日本: www.honeywellaidc.com をご覧ください。  
如要到中www.honeywellaidc.com简体。  
查看繁体版请登陆 www.honeywellaidc.com  
한글 www.honeywellaidc.com 로 이동합니다 .  
GRNT1980-QS Rev A  
12/14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting the Scanner  
When connecting the scanner, make sure the cable is pushed tightly  
into the scanner. Loosen the locking plate and slide it over the base  
of the cable connector to lock the cable in place. Tighten the screw.  
USB:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS232 Serial Port:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reading Techniques  
Near Distance Scanning  
Use the red lighting and center the box over  
the bar code when scanning at a near  
distance (less than 11.8 inches / 30 cm).  
The laser aimer will be to the right of the  
center of the bar code.  
Far Distance Scanning  
Use the laser aimer and aim at the center of the  
bar code when scanning at a far distance (up to 50  
feet / 15.2 meters).  
When scanning at far distances the red lighting  
may not be apparent.  
Note: If the bar code is highly reflective (e.g., laminated), you may  
need to tilt the scanner at an angle so the bar code can be  
scanned.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Standard Product Defaults  
The following bar code resets all standard product default settings.  
Standard Product Defaults  
USB Serial  
Scan the following code to program the scanner to emulate a regular  
RS232-based COM Port. If you are using a Microsoft® Windows®  
PC, you will need to download a driver from the Honeywell website  
(www.honeywellaidc.com). The driver will use the next available  
COM Port number. Apple® Macintosh computers recognize the  
scanner as a USB CDC class device and automatically use a class  
driver.  
USB Serial  
Note: No extra configuration (e.g., baud rate) is necessary.  
USB PC Keyboard  
Scan the following code to program the scanner for a USB PC  
Keyboard.  
USB PC Keyboard  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard Country  
Scan the Program Keyboard Country bar code below, then scan  
the numeric bar code(s) from page 12, then the Save bar code to  
program the keyboard for your country. As a general rule, the  
following characters are not supported by the scanner for countries  
other than the United States:  
@ | $ # { } [ ] = / ‘ \ < > ~.  
Program Keyboard Country  
Country Code  
Belgium  
Scan Country Code  
Scan  
1
8
2
3
4
7
Italy  
5
Denmark  
Norway  
9
Finland  
Spain  
10  
6
France  
Switzerland  
USA (Default)  
Germany/Austria  
Great Britain  
0
Save  
Note: For a complete list of country codes, see the User’s Guide for  
your product at our website, www.honeywellaidc.com.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Aimer Delay  
Set the time between when the trigger is pulled, turning the laser  
aimer on, and when the picture is taken. During the delay time, the  
laser aimer appears so you can find the bar code. When the delay is  
over the LEDs turn on and the scanner reads the bar code. This can  
be helpful when reading at far distances.  
Aimer Delay 1000 ms  
Aimer Delay Off  
(Default)  
Note: For more options, see the User’s Guide for your product at our  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Suffix  
If you want a carriage return after the bar code, scan the Add CR  
Suffix bar code. To add a tab after the bar code, scan the Add Tab  
Suffix bar code. Otherwise, scan the Remove Suffix bar code to  
remove the suffixes.  
Add CR Suffix  
Add Tab Suffix  
Remove Suffix  
Add Code ID Prefix to all Symbologies  
Scan the following bar code if you wish to add a Code ID prefix to all  
symbologies at once.  
Add Code ID Prefix To All Symbologies  
(Temporary)  
Note: For a complete list of Code IDs, see the User’s Guide for your  
product at our website, www.honeywellaidc.com.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Function Code Transmit  
When this selection is enabled and function codes are contained  
within the scanned data, the scanner transmits the function code to  
the terminal. Charts of these function codes are provided in your  
User’s Guide.  
Enable  
(Default)  
Disable  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Data Format Editor Instructions  
The following are abbreviated instructions for entering a data format.  
For complete instructions refer to your User’s Guide, available at our  
1. Scan the Enter Data Format bar code.  
2. Primary/Alternate Format: scan 0 for Primary Format  
3. Terminal Type: scan 099 for any terminal type  
4. Code I.D.: scan 99 for any bar code type  
5. Length: scan 9999 for any length bar code.  
6. Editor commands: use the Programming Chart that follows.  
7. Scan Save to save your entries.  
Enter Data Format  
Clear All Data Formats  
Save  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming Chart  
0
1
2
4
6
3
5
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
9
A
C
E
B
D
F
Save  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EZConfig-Scanning  
To access additional features for the scanner use EZConfig-  
Scanning, an online configuration software tool, available from our  
Technical Assistance  
Contact information for technical support, product service, and repair  
can be found at www.honeywellaidc.com.  
Limited Warranty  
product’s warranty information.  
Patents  
For patent information, refer to www.hsmpats.com.  
User Documentation  
For localized versions of this document, and to download the User’s  
Guide, go to www.honeywellaidc.com.  
Disclaimer  
Honeywell International Inc. (“HII”) reserves the right to make changes in  
specifications and other information contained in this document without prior  
notice, and the reader should in all cases consult HII to determine whether  
any such changes have been made. The information in this publication does  
not represent a commitment on the part of HII.  
HII shall not be liable for technical or editorial errors or omissions contained  
herein; nor for incidental or consequential damages resulting from the  
furnishing, performance, or use of this material.  
This document contains proprietary information that is protected by copyright.  
All rights are reserved. No part of this document may be photocopied,  
reproduced, or translated into another language without the prior written  
consent of HII.  
2015 Honeywell International Inc. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Outboard Motor 3A0869J User Manual
Graco Water Pump SP 218 335 User Manual
Grandstream Networks IP Phone GXP 2020 User Manual
Grizzly Drill G0720R User Manual
Haier Flat Panel Television LE42H5000 User Manual
Harbor Freight Tools Utility Trailer 90154 User Manual
Honeywell Network Hardware NETAXS 123 User Manual
HP Hewlett Packard Switch HN220E User Manual
Hunter Fan Fan 23782 User Manual
Ice O Matic Ice Maker ICE1005 User Manual