| DN-7107:A • K-20   N-ANN-RLY   Relay Module   Annunciators   General   The N-ANN-RLY relay module provides 10 programmable   Form-C relays when used with a compatible FACP (Fire Alarm   Control Panel). The N-ANN-RLY module may be mounted   inside the FACP main circuit board chassis or in the battery   area of the enclosure using optional mounting bracket P/N:   ANN-MBRLY. Reference Installation Instructions document   #53318.   The N-ANN-RLY and the FACP communicate over a two-wire   serial interface employing the ANN-BUS communication for-   mat. An additional two wires are used for 24-volt DC power. A   single four-conductor unshielded cable may be used for both   power and data communications.   Up to eight ANN-BUS devices may be connected to the ANN-   BUS of each FACP.   Features   • N-ANN-RLY connects to the ANN-BUS terminal on the   FACP and requires minimal programming.   • • Provides 10 programmable Form-C relays.   Ten Form-C relays can be programmed for various func-   tions; Alarm, Trouble, Supervisory, AC Loss, Waterflow   Delay, Input Zones and Silenceable Alarm.   The ANN-BUS   POWERING THE DEVICES ON THE ANN-BUS FROM   AUXILIARY POWER SUPPLY   ANN-BUS devices can be powered by an auxiliary power sup-   ply when available panel power is exceeded. See FACP man-   ual for information.   • • • • Compatible with the FireWarden 50, SFP-5UD, RP-2001,   RP-2002 and SFP-10UD.   May be powered by 24 VDC from the host FACP or by   remote power supply (requires 24 VDC).   Up to eight ANN-BUS devices may be connected to the   ANN-BUS of each FACP.   ANN-BUS DEVICE ADDRESSING   Each ANN-BUS device requires a unique address (ID Num-   ber) in order to communicate with the FACP. A maximum of   eight devices can be connected to the FACP ANN-BUS com-   munication circuit. See the FACP manual for more information.   Listed to UL Standard 864, 9th Edition.   Specifications   • Maximum ANN-BUS Voltage: 24 VDC   WIRE REQUIREMENTS   • Maximum Current:   The N-ANN-RLY connects to the FACP ANN-BUS communica-   tions circuit. To determine the type of wire and the maximum   wiring distance, calculate the total worst case current draw for   all modules on a single 4-conductor bus. Use the table on the   following page to determine the maximum distance the mod-   ules can be located from the FACP. In general, the wire length   is limited by resistance, but for heavier wire gauges, capaci-   tance is the limiting factor. These cases are marked in the   chart with an asterisk (*). Maximum length can never be more   than 6,000 feet (1,800 m), regardless of gauge used.   – Alarm: 75 mA Standby: 15 mA   Ambient Temperature: 32ºF to 120ºF (0ºC to 49ºC)   • • Relative Humidity: 93% ± 2% RH (noncondensing) at 32ºC   ± 2ºC (90ºF ± 3ºF)   • • • For use indoors in a dry location   Connections to FACP are power-limited and supervised.   Relay Contact Ratings: 2 Amps @ 30VDC (Resistive) 0.5   Amps @ 30VAC (Resistive)   Refer to the appropriate FACP manual for wiring details.   Agency Listings and Approvals   Ordering Information   The listings and approvals below apply to the N-ANN-RLY. In   some cases, certain modules may not be listed by certain   approval agencies, or listing may be in process. Consult fac-   tory for latest listing status.   • N-ANN-RLY Relay Module provides 10 programmable Form   C relays.   • ANN-MBRLY Optional mounting bracket.   • UL: S635   • CSFM:7165-0028:245; 7165-0028:246   • MEA: 333-07-E   DN-7107:A • 1/10/08 — Page 1 of 2   Download from Www.Somanuals.com. All Manuals Search And Download.   |