The Honeywell 63500 Series air cleaner is a 3  
speed air cleaner operated by moving the  
speed control knob in the base from the Off ("0")  
position to the high ("3") position. Allow the unit  
to operate for a few seconds at high speed, then  
leave the control knob in the high position for  
faster, powerful room cleaning, or move the knob  
to the lower setting for quieter operation. The  
63500 Series will clean and recirculate the air  
in a 20' x 22' room six times an hour (at high  
speed).  
64500 Series...  
The Honeywell 64500 Series air cleaner is a 3  
speed air cleaner operated by moving the speed  
control knob on the base from the Off ("0")  
position to the high (3") position. Allow the unit  
to operate for a few seconds at high speed, then  
leave the control knob in the high position for  
faster, powerful room cleaning or move the knob  
to the lower setting for quieter operation. The  
64500 Series will clean and recirculate the air  
in a 22' x 23' room six times an hour (at high  
speed).  
450i  
Construction...  
Your Honeywell air cleaner has five  
basic components: the base assembly  
(with controls and motor), the lid  
assembly, the protective screen, the  
activated carbon prefilter, and the  
HEPA filter.  
Lid Assembly  
Protective  
Screen  
HEPA Filter  
Activated  
Carbon  
Prefilter  
Base  
Assembly  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For Best Performance...  
We recommend that you operate your Honeywell air cleaner 24 hours a day because  
indoor air can be quickly contaminated by activity in a room, infiltration of outside air,  
and generation by sources of contamination.  
The Honeywell HEPA air cleaner is ready to begin cleaning air as soon as it is  
removed from the carton and plugged in. Because it circulates air in a 360 degree  
pattern around the air cleaner, it can be placed on the floor in almost any  
location. However, for best performance the air outlet slot should not be blocked for  
at least three feet in all directions.  
Replacement Filters...  
Select the proper replacement filter for your Honeywell HEPA air cleaner from the  
chart below:  
HEPA Filter  
Part Number  
Carbon Prefilter  
Part Number  
Model No.  
61500  
62500  
63500  
64500  
21500  
22500  
24000  
29500  
32002  
33002  
34002  
35002  
Replacement filters may be purchased from the retail store or ordered from the dealer  
where you purchased the product. If you cannot locate one in your area, please call  
our Consumer Relations Dept. at (800) 332-1110 and we will direct you to a stocking  
dealer.  
Service...  
Should your air cleaner require service, please return the complete unit, transportation  
prepaid to:  
Honeywell Consumer Products Business  
Southpoint Distribution Center  
4755 Southpoint Drive  
Memphis, TN 38118 USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter Replacement...  
With proper maintenance, your Honeywell air cleaner is designed to provide years of  
high efficiency air cleaning.Your Honeywell air cleaner contains two filters: one activated  
carbon prefilter and one primary HEPA filter.  
The activated carbon prefilter helps capture large airborne particles, and helps remove  
odors. The prefilter should be replaced every 3 months.You may need to replace the  
prefilter more often if the unit is used in a smoking environment or if unpleasant  
odors persist.  
The primary HEPA filter should remain effective for 1 to 3 years, depending upon the  
environment in which the air cleaner is operating. Honeywell recommends changing the  
HEPA filter based upon operation conditions–every 3 years for light usage,. 2 years for  
normal usage and 1 year for heavy usage.  
Our recommendations regarding filter replacement intervals are intended as guidelines  
only and are based upon reasonable filter life expectancy in homes with normal levels of  
particle generation. If there are sources of large amounts of particle generation (such as  
woodworking or heavy smoking) the useful life of the activated carbon prefilter and HEPA  
filter in your air cleaner may be reduced .  
Whenever the combined air resistance of the activated carbon filter and primary HEPA  
filter becomes excessive due to the amount of contaminants they have captured, the air  
cleaner will begin to audibly pulsate. Instead of a steady stream of air, rapid "puffs" of air  
may be felt at the outlet slot. When this occurs, one of two conditions exists:  
1. The activated carbon prefilter is clogged and must be replaced.  
2. If the unit continues to pulsate after a new prefilter is installed,  
the useful life of the HEPA filter has been reached and it must be replaced.  
Important...  
Replace the activated carbon prefilter at least every 3 months.The activated  
carbon prefilter is the element of your air cleaner that helps remove odors and  
gaseous compounds. Under normal household conditions the odor adsorption  
capability will be used up in about 3 months.  
If there are heavy concentrations of odors, smoke, or gases (such as tobacco smoke) in  
the home, you may need to change the activated carbon prefilter more often.  
We DO NOT recommend operating the air cleaner without the activated carbon prefilter  
because the primary HEPA filter does NOT absorb odors or gaseous compounds. In fact,  
the HEPA filter may become contaminated by these odors and begin to omit the odor  
captured.  
CAUTION: Do not attempt to wash either the activated carbon prefilter or the HEPA filter.  
They are not washable and washing will damage the filters.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to Change the Filters...  
CAUTION: DISCONNECT FROM POWER SUPPLY BEFORE SERVICING  
The only two parts requiring any service are the activated carbon  
prefilter and the HEPA filter. No tools are needed. To change either  
filter, disassemble the unit as shown.  
1. Loosen the carrying handle by turning it counterclockwise and lift  
lid and protective screen from unit.  
2. Lift HEPA filter and activated carbon Prefilter from the base.  
3. Remove the two plastic clips from the top and bottom of the acti-  
vated carbon prefilter and remove it from the HEPA filter cartridge.  
4. Wrap the new activated carbon prefilter around the HEPA filter  
cartridge and secure with plastic clips.  
Reassemble your Honeywell air cleaner as described below:  
1. Place the assembled HEPA filter and the activated carbon prefilter  
on the base.  
2. Replace the lid and protective screen.  
3. Reattach the carrying handle and turn it clockwise until securely  
tightened.  
If the Air Cleaner does not operate...  
Check to make sure that the power cord is correctly connected to the outlet.  
Test the outlet with another appliance or lamp.  
Check the fuse or circuit breaker. The outlet may be overloaded if other appli-  
ances are also in use. Determine and correct the cause of the overload.  
The thermal overload protection device on the air cleaner's motor may have  
engaged. Turn the air cleaner's motor control to OFF and wait 30 to 45 minutes.  
Then, plug it in and turn ON again.  
If none of the above procedures restore operation, return your unit to the store or if  
the store's return policy does not allow, return the complete unit per the instructions  
in the service section of this owner's guide. Do not attempt to repair the unit yourself.  
Storage...  
If you store your Honeywell HEPA air cleaner for more than 30 days,  
we recommend:  
Remove both the primary HEPA filter and the activated carbon prefilter from the unit.  
Discard the prefilter.  
Wrap the HEPA filter in an air-tight plastic bag or plastic wrap. Be sure that the  
filter is totally sealed.  
To restore the air cleaner to service, unwrap the HEPA filter, install a new  
activated carbon prefilter, and replace both filters in the air cleaner.  
(See "How to change the Filters..." section for proper installation.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Instructions...  
Please read all instructions before using this product. Save these instructions for easy  
reference.  
When using electrical appliances, basic precautions should always be followed to reduce  
breakage, risk of fire, electric shock and injury to persons including the following:  
1. Read all instructions before operating the air cleaner.  
2. Place air cleaner where it is not easily knocked over by persons in the  
household.  
3. Always unplug when not in use.  
4. Do not use any product with a damaged cord or plug or if product malfunctions, is  
dropped or damaged in any manner. Keep the cord away from heated surfaces.  
5. Do not use air cleaner outdoors.  
6. Never use air cleaner unless it is fully assembled.  
7. Do not run power cord under carpets & do not cover with throw rugs. Arrange  
cord such that it will not be tripped over.  
8. Do not use air cleaner where combustible gases or vapors are present.  
9. Do not operate the air cleaner near a humidifier or in a bathroom, laundry area or  
other damp location.  
10. To disconnect the air cleaner, first turn speed control to OFF position and remove  
plug from the outlet.  
11. The air cleaner must be used in its upright position.  
12. Do not allow foreign objects to enter ventilation or exhaust opening as this  
may cause electric shock or damage to the air cleaner. Do not block air outlets  
or intakes.  
13. Locate air cleaner near power outlet and avoid using an extension cord.  
14. The air cleaner has a polarized plug (one blade is wider than the other).  
To reduce risk of shock, this plug is intended to fit in a polarized outlet only one  
way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit,  
contact a qualified electrician. DO NOT attempt to defeat this safety feature.  
15. Do not sit, stand or place heavy objects on the air cleaner.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Limited Warranty...  
Honeywell HEPA Air Cleaner  
D. This warranty DOES NOT cover  
the prefilter or the HEPA filter except for  
material or workmanship defects.  
Model No. 61500, 62500, 63500  
and 64500  
E. Return defective product to the  
following address with a brief description  
of the problem. Include proof-of-  
purchase and a U.S. $10.00/Can $13.00  
check or money order for handling,  
return packing and shipping charges.  
Please include your name, address and  
daytime phone number. You must  
prepay shipping charges. Mark carton  
"Attention Repair Department"  
This product has been engineered  
and crafted with great care for your  
satisfaction. Be sure to fill out and  
return the enclosed card within  
7 days of purchase.  
A. This 5 year limited warranty applies  
to repair or replacement of product  
found to be defective in material or  
workmanship. This warranty does not  
apply to damage resulting from commer-  
cial, abusive, unreasonable use or sup-  
plemental damage. Defects that are the  
result of normal wear and tear will not  
be considered manufacturing defects  
under this warranty. Honeywell  
Consumer Products Business is not  
liable for incidental or consequential  
damages of any nature. Any implied  
warranty of merchantability or fitness for  
a particular purpose on this product is  
limited in duration to the duration of this  
warranty. Some states do not allow the  
exclusion or limitation of incidental or  
consequential damages or limitations on  
how long an implied warranty lasts, so  
the above limitations or exclusions may  
not apply to you. This warranty gives  
you specific legal rights, and you also  
may have other rights which vary from  
state to state. This warranty applies only  
to the original purchaser of this product.  
Ship to:  
Honeywell Consumer Products Business  
Honeywell, Inc.,  
Southpoint Distribution Center  
4755 Southpoint Drive  
Memphis, TN 38118  
U.S.A.  
In Canada:  
Honeywell Consumer Products Canada  
510 Bronte St. South Milton, Ontario  
Canada L9T 2X6  
If you experience a problem with your  
Air Cleaner, please see owner's guide  
for instructions. Please do not attempt to  
repair the air cleaner yourself. Doing so  
will void the warranty and could cause  
damage or personal injury. If the prob-  
lem still persists, please call:  
B. At its option, Honeywell Consumer  
Products Business will repair or replace  
this product if it is found to be defective  
in material or workmanship. Defective  
product should be returned immediately  
to Honeywell Consumer Products  
Business.  
Honeywell Consumer Products Business  
Consumer Relations Dept.  
Toll Free 1-800-332-1110.  
Business Hours:  
Mon.Fri.. 8:00am10.00pm (EST)  
Sat.Sun. 8:30am5:00pm (EST).  
C. This warranty does not cover  
damage resulting from unauthorized  
attempts to repair or from any use not in  
accordance with this manual.  
Mail Questions or Comments to:  
Honeywell Consumer Products Business  
Consumer Relations Dept.  
250 Turnpike Road  
Southborough, MA 01772  
U.S.A.  
© 1998 All Rights Reserved  
Honeywell Inc.  
250 Turnpike Road  
Southborough, MA 01772  
AC7134.98  
035-02321-000  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Sander G1531 User Manual
Harbor Freight Tools Automobile Accessories 34313 User Manual
Harbor Freight Tools Work Light 94137 User Manual
Heatcraft Refrigeration Products Refrigerator H IM FL1A User Manual
Honeywell Thermostat CM721 User Manual
Honeywell Weather Radio C7772A User Manual
Hotpoint Range RGB528PENWW User Manual
HP Hewlett Packard Laptop 4320T User Manual
Husqvarna Snow Blower ST261E User Manual
Hypertec Mouse HKBRAIPWHED User Manual