Heat-N-Glo Fireplace
Installers Guide
U.S. Patents 4,793,322; 4,875,464; 5,000,162 and Patents Pending
Models:
8000 DVTFL
6000 DVTFL
6000 XLT
Canadian Patent 1,297,746
Underwriters Laboratories Listed
6000 ARCH
SL-42 DVT
READ THIS MANUAL BEFORE INSTALLING
OR OPERATING THIS APPLIANCE. THIS
WARNING
IF THE INFORMATION IN
INSTALLERS GUIDE MUST BE LEFT WITH
THESE INSTRUCTIONS IS
APPLIANCE FOR FUTURE REFERENCE.
NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY,
OR LOSS OF LIFE.
WARNING: IMPROPER
INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE.
REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL
INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENGY, OR THE GAS SUPPLIER.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
1.This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
• If you cannot reach your gas supplier, call the
fire department.
2. This appliance is only for use with the
type of gas indicated on the rating
plate. This appliance is not convertible
for use with other gases, unless a
certified kit is used.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Please contact your Heat-N-Glo Fireplace
dealer for any questions or concerns. For the
number of your nearest Heat-N-Glo dealer,
please call 612-890-8367.
Printed in U.S.A.
Copyright 1997,
Heat-N-Glo Fireplace Products, Inc.
6665 West Highway 13, Savage, MN 55378
484-980-B 7/97
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety and Warning Information ................... i
Section 1: Approvals and Codes ................... 1
Approval Listings and Codes ............................ 1
Appliance Certification .................................. 1
Installation Codes .......................................... 1
High Altitude Installations ............................ 1
Table of
Contents
Section 2: Getting Started ............................. 2
Introducing the Heat-N-Glo Gas Fireplaces ...... 2
Pre-installation Preparation ............................... 2
Section 3: Installing the Fireplace ................ 6
Step 1 Locating the Fireplace .......................... 6
Step 2 Framing the Fireplace .......................... 7
Step 3 Installing the Vent System.................... 8
A. Vent System Approvals ............................. 8
B. Installing Vent Components.................... 17
C. Vent Termination..................................... 23
Step 4 Positioning, Leveling, and
Securing the Fireplace ........................ 28
Step 5 The Gas Control Systems ................... 28
Step 6 The Gas Supply Line .......................... 29
Step 7 Gas Pressure Requirements................ 30
Step 8 Wiring the Fireplace ........................... 31
Step 9 Finishing ............................................ 33
Step 10 Installing Trim, Logs, and
Ember Material .................................. 34
Installing the Trim........................................ 34
Positioning the Logs .................................... 35
Placing the Ember Material.......................... 35
Step 11 Before Lighting the Fireplace ............ 37
Step 12 Lighting the Fireplace ....................... 37
After the Installation ........................................ 37
Section 4: Maintenance and Servicing ....... 38
Section 5: Replacement Parts
andAccessories .......................... 40
Replacement Parts ........................................... 40
Accessories ...................................................... 43
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Approval Listings Appliance Certification
The Heat-N-Glo fireplace models discussed in this
Installers Guide have been tested to certification
standards and listed by the applicable laboratories.
and Codes
CERTIFICATION
MODEL
LABORATORY
TYPE
STANDARD
1
8000DVTFL
Underwriters
Laboratories
Direct Vent
Decorative
ANSI Z21.50•CGA2.22
Approvals
and Codes
6000DVTFL
6000ARCH
6000XLT
Underwriters
Laboratories
Direct Vent
Decorative
ANSI Z21.50•CGA2.22
ANSI Z21.50•CGA2.22
Underwriters
Laboratories
Direct Vent
Decorative
Underwriters
Laboratories
Direct Vent
Decorative
Wall Furnace
ANSI Z21.50•CGA2.22
Z21.44/IR#41/CANI-2.19
SL-42DVT
Underwriters
Laboratories
Direct Vent
Decorative
ANSI Z21.50•CGA2.22
Installation Codes
The fireplace installation must conform to local codes. Before installing the
fireplace, consult the local building code agency to ensure that you are in
compliance with all applicable codes, including permits and inspections.
In the absence of local codes, the fireplace installation must conform to the
National Fuel Gas CodeANSI Z223.1 (in the United States) or the CAN/CGA-
B149 Installation Codes (in Canada). The appliance must be electrically
grounded in accordance with local codes or, in the absence of local codes with
the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the
CSA C22.1Canadian Electric Code (in Canada).
These models may be installed in a bedroom or bed-sitting room in the U.S.A.
and Canada.
High Altitude Installations
U.L. Listed gas fireplaces are tested and approved for elevations from 0 to 2,000
feet in the U. S. A. and from 0 to 4,500 feet in Canada.
When installing this fireplace at an elevation above 2,000 feet (in the United
States), it may be necessary to decrease the input rating by changing the
existing burner orifice to a smaller size. Input should be reduced four percent
(4%) for each 1,000 feet above sea level, unless the heating value of the gas has
been reduced, in which case this general rule will not apply. To identify the proper
orifice size, check with the local gas utility.
When installing this fireplace at an elevation between 2,000 and 4,500 feet (in
Canada), the input rating must be reduced by ten percent (10%).
When installing this fireplace at an elevation above 4,500 feet (in Canada), check
with local authorities.
Consult your local gas utility for assistance in determining the proper orifice for
your location.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Introducing the
Heat-N-Glo
Gas Fireplaces
Heat-N-Glo direct vent gas fireplaces are designed to
operate with all combustion air siphoned from outside
of the building and all exhaust gases expelled to the
outside.
The information contained in this Installers Guide,
unless noted otherwise, applies to all models and gas
control systems.
Gas fireplace diagrams, including the dimensions, are
shown in this section.
2
Pre-installation
Preparation
This gas fireplace and its components are tested and
safe when installed in accordance with this Installers
Guide. Report to your dealer any parts damaged in
shipment, particularly the condition of the glass. Do
not install any unit with damaged, incomplete, or
substitute parts.
Getting
Started
The vent system components and trim doors are
shipped in separate packages. The gas logs are
factory installed (Model 8000DVTFL) and are
packaged separately and must be field installed
(Models 6000DVTFL, 6000ARCH, 6000XLT, SL-
42DVT). Read all of the instructions before
starting the installation. Follow these instructions
carefully during the installation to ensure
maximum safety and benefit. Failure to follow
these instructions will void the owner’s warranty
and may present a fire hazard.
The Heat-N-Glo Fireplace Products, Inc. Warranty will
be voided by, and Heat-N-Glo Fireplace Products, Inc.
disclaims any responsibility for, the following actions:
• Installation of any damaged fireplace or vent system
component.
• Modification of the fireplace or direct vent system.
• Installation other than as instructed by Heat-N-Glo
Fireplace Products, Inc.
• Improper positioning of the gas logs or the glass
door.
• Installation and/or use of any component part not
manufactured and approved by Heat-N-Glo Fire-
place Products, Inc., not withstanding any indepen-
dent testing laboratory or other party approval of
such component part or accessory.
ANY SUCH ACTION MAY POSSIBLY CAUSE A
FIRE HAZARD.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
When planning a fireplace installation, it’s necessary to determine:
• Where the unit is to be installed.
• The vent system configuration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and finishing details.
• Whether optional accessories—devices such as a fan, wall switch, or remote
control—are desired.
If the fireplace is to be installed on carpeting or tile, or on any combustible
material other than wood flooring, the fireplace should be installed on a metal or
wood panel that extends the full width and depth of the fireplace.
3
Figure 1. Diagram of 8000DVTFL
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2. Diagram of 6000DVTFL, 6000XLT and 6000ARCH
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 3. Diagram of SL-42DVT
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 1
Locating the
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
3
Installing the
Fireplace
Figure 4. Fireplace Dimensions, Locations, and
Space Requirements
Clearance Requirements
The top, back, and sides of the fireplace are defined
by stand-offs.
Minimum Clearances from the Fireplace to
Combustible Materials
Glass
Front
Back of
Fireplace
Sides of
Fireplace
Top of
Fireplace
Floor
Ceiling
36 inches
(914 mm)
0
1/2 inch
(13 mm)
1/2 inch
(13 mm)
3-1/2 inches
(89 mm)
31 inches
(787 mm)
The minimum clearance to a perpendicular wall
extending past the face of the fireplace is one inch (25
mm).
For 6000 Series Models, the back of the fireplace may
be recessed 21-1/2 inches (546 mm) into
combustible construction.
For the 8000 DVTFL, the back of the fireplace may be
recessed 24-7/8 inches (641 mm) into combustible
construction.
For the SL-42DVT, the back of the fireplace may be
recessed 16 1/2-inches (419mm) into combustible
construction.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Minimum Clearances from the Vent Pipe to
Combustible Materials
For Vertical
Sections
For Horizontal Sections
At Wall Firestops
Top
Bottom
Sides
Top
Bottom
Sides
3 inches 1 inch
(75 mm) (25 mm) (25 mm)
1 inch
1 inch
(25 mm)
2-1/2 inches 1/2 inch
(63.7 mm) (13 mm) (25 mm)
1 inch
For minimum clearances, see the direct vent
termination clearance diagrams on pages 25 and 27 in
this section.
Step 2
Framing the
Fireplace
Fireplace framing can be built before or after the
fireplace is set in place. Framing should be positioned
to accommodate wall coverings and fireplace facing
material. The diagram below shows framing reference
dimensions.
MEASURE FIREPLACE DIMENSIONS, AND
VERIFY FRAMING METHODS AND WALL
COVERING DETAILS, BEFORE FRAMING
CONSTRUCTION BEGINS.
CAUTION
The framing
headers may
rest on the
fireplace
stand-offs.
B
C
A
Framing should be
constructed of 2 X 4
lumber or heavier.
Model
A
B
C
D
8000DVTFL
6000DVTFL& 6000XLT42
6000ARCH
SL-42DVT
49
42-3/8
38-1/4
42-3/8
25-3/8 47
22
22
43-1/4
42*
48-1/4**
49
53-5/8
45-3/4
42-7/8
17
NOTE: DIMENSIONS SHOWN IN INCHES
*SURROUND IN FRONT OF FINISHED WALL
**SURROUND FLUSH WITH FINISHED WALL
Figure 5. Framing Dimensions
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 3
Installing the
Vent System
A. Vent System Approvals
Models 8000DVTFL, 6000DVTFL, 6000XLT, and
6000ARCH are approved to use D-series direct vent
pipe components and terminations. Model SL-
42DVT is approved to us SL-D-series components
and terminations. Approved vent system components
are labeled for identification. NO OTHER VENTING
SYSTEMS OR COMPONENTS MAY BE USED.
Detailed installation instructions are included with
each vent termination kit and should be used in
conjunction with this Installers Guide. The drawing
below shows vent system components and
terminations.
Identifying Vent Components
The vent systems installed on this gas fireplace may
include one, two, or three 90°elbow assemblies. The
relationships of vertical rise to horizontal run in vent
configurations using 90° elbows MUST BE strictly
adhered to. The rise to run relationships are shown in
the venting drawings and tables. Refer to the
diagrams on the next several pages.
Vent system components
Vent system
VERTICAL
termination kits
TERMINATION
STORM COLLAR
D-SERIES
ROOF FLASHING
HORIZONTAL
HORIZONTAL PIPE
TERMINATION
SUPPORT
DVK-TVCD
DVK-01D
DVK-02D
PIPE LENGTH
WALL FIRESTOP
CEILING
FIRESTOP
WALL BRACKET
DVK-01TRD
DVK-02TRD
90 DEGREE
ELBOW
DVK-01SD
DVK-02SD
SL-D-SIES
ER
SLK-TVCD
SLK-991D
SLK-01D
SLK-01TRD
Figure 6. Vent Components and Terminations
8
Download from Www.Somanuals.com. All Manuals Search And Download.
DV-45D
DV-90D
6-7/16"
6-5/32"
(156 mm)
(164 mm)
8-1/2"
(216 mm)
8-1/2"
(216 mm)
11-5/8"
(295 mm)
11-1/16"
(281 mm)
7-3/8"
(187 mm) (149 mm)
5-7/8"
6-1/2"
(165 mm)
5-1/16"
(129 mm)
8-5/8"
(220 mm)
8 5
8-5/8"
(220 mm)
11-15/16"
(303 mm)
DV-48D
DV-36D
47-3/4"
(1.2 m)
35-3/4"
(908 mm)
DV-12D
DV-09D
DV-06D
11-3/4"
(298 mm)
8-3/4"
(222 mm)
5-3/4"
(146 mm)
NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93 mm)AT EACH JOINT.
Figure 7. D-Series Direct Vent Component Specifications
(5-inch inner pipe/8 5/8-inch outer pipe)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 8. SL-D-Series Direct Vent Component Specifications
(4-inch inner pipe/6 5/8-inch outer pipe)
10
Download from Www.Somanuals.com. All Manuals Search And Download.
VERTICAL VENTING
V (FT.)
NOTE: MODEL 6000 ARCH
A 12-inch length of straight vent pipe MUST be
the first vent component attached to the unit.
40' MAX. (12.4 M)
CAP
Figure 9. Vertical Venting
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Model 6000XLT & 8000DVTFL
VENTING WITH ONE (1) 90° ELBOW
V (FT.)
H (FT.) (8000 & 6000’s)
H (FT.) SL-42DVT
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
6' MAX. (1.86 m)
12' MAX. (3.66 m)
18' MAX. (5.58 m)
24' MAX. (8.44 m)
3’ MAX. (914mm)
6’ MAX. (1.83m)
9’ MAX. (2.74m)
12’ MAX. (3.66m)
20' MAX. (6.2 m)
24' MAX. (8.44 m)
12’ MAX. (3.66m)
(21' IN CANADA 6.3 m)
FOR SL-42DVT
NOTE: IF A 90° ELBOW IS FIRST
ATTACHED TO THE UNIT, THE
MAXIMUM HORIZONTAL RUN H IS
2-FEET (610 MM).
V
H
FOR 8000DVTFL, 6000DVTFL, 6000XLT
NOTE: IF A 90° ELBOW IS FIRST
ATTACHED TO THE UNIT, THE MAXIMUM
HORIZONTAL RUN H IS 3-FEET (914 MM).
NOTE: MODEL 6000 ARCH
A 12-INCH LENGTH OF STRAIGHT
VENT PIPE MUST BE THE FIRST
VENT COMPONENT ATTACHED
TO THE UNIT.
H
V
Figure 10. Venting with One 90° Elbow
NOTE: For corner installations: A 6-inch (152mm) MINIMUM length of
straight pipe must be first attached to the fireplace before 90O eblow.
This will allow the vent pipe to clear the top standoffs.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTING WITH TWO (2) 90° ELBOWS
V (FT.)
H + H1 (FT.) (8000 & 6000’s)
H + H1 (FT.) (SL-42DVT)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
6' MAX. (1.86 m)
12' MAX. (3.72 m)
18' MAX. (5.58 m)
24' MAX. (8.44 m)
3' MAX. (914 mm)
6' MAX. (1.83 m)
9' MAX. (2.74 m)
12' MAX. (3.66 m)
20' MAX. (6.2 m)
24' MAX. (8.44 m)
12' MAX. (3.66 m)
(21' IN CANADA 6.5 m)
NOTE: MODEL 6000 ARCH
A 12-inch length of straight vent pipe MUST be
the first vent component attached to the unit.
H1
V
H
Figure 11. Venting with two 90° elbows
13
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTING WITH TWO (2) 90° ELBOWS
V (FT.)
H (FT.) (8000 & 6000’s)
H (FT.) (SL-42DVT)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
6' MAX. (1.6 m)
12' MAX. (3.72 m)
18' MAX. (5.58 m)
24' MAX. (8.44 m)
3' MAX. (914 mm)
6' MAX. (1.86 m)
9' MAX. (2.74 m)
12' MAX. (3.66 m)
24' MAX. (8.44 m)
12' MAX. (3.66 m)
(21' IN CANADA 6.5 m)
NOTE: V + V1 MAX. 20' (6.2 m)
NOTE: MODEL 6000 ARCH
A 12-inch length of straight vent pipe MUST
be the first vent component attached to the
unit.
H
V1
V
Figure 12. Venting with two 90° elbows
14
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTING WITH THREE (3) 90° ELBOWS
V (FT.)
H (FT.) (8000 & 6000’s)
H (FT.) (SL-42DVT)
1' MIN. (305 mm)
6' MAX. (1.86 m)
3' MAX. (914 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
12' MAX. (3.72 m)
18' MAX. (5.58 m)
24' MAX. (8.44 m)
24' MAX. (8.44 m)
6' MAX. (1.86 m)
9' MAX. (2.74 m)
12' MAX. (3.66 m)
12' MAX. (3.66m)
NOTE: H + H1 MAX. 24' (8.44 m) (8000 & 6000’s)
NOTE: H + H1 MAX. 12' (3.66 m) (SL-42DVT)
V + V1 MAX. 20' (6.2 m)
NOTE: MODEL 6000 ARCH
A 12-inch length of straight vent pipe MUST be
the first vent component attached to the unit.
H
H1
V1
V
Figure 13. Venting with three 90° elbows
15
Download from Www.Somanuals.com. All Manuals Search And Download.
VENTING WITH THREE (3) 90° ELBOWS
V (FT.)
H + H1 (FT.) (8000 & 6000’s)
H + H1 (FT.) (SL-42DVT)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
6' MAX. (1.86 m)
12' MAX. (3.72 m)
18' MAX. (5.58 m)
24' MAX. (8.44 m)
3' MAX. (914 mm)
6' MAX. (1.86 m)
9' MAX. (2.74 m)
12' MAX. (3.66 m)
24' MAX. (8.44 m)
12' MAX. (3.66 m)
NOTE: V + V1 MAX. 20' (6.2 m)
V1
V
H1
H
Figure 14. Venting with three 90° elbows
16
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Installing Vent Components
1. Attach the First Vent Component to the
Starting Collars
To attach the first vent component to the starting
collars of the fireplace:
• Apply a 3/8 inch (9.5 mm) bead of stove cement
around the inner pipe fireplace starting collar.
• Make sure that the fireplace rope gasket supplied
with the fireplace seals between the first
vent component and the outer fireplace wrap.
• Lock the vent components into place by sliding the
concentric pipe sections with four (4) equally
spaced interior beads into the fireplace collar or
previously installed component end with four (4)
equally spaced indented sections.
• When the internal beads of each outer pipe line up,
rotate the pipe section clockwise about one-quarter
(1/4) turn. The vent pipe is now locked together.
• The first 90° elbow installed in the vent system of a
rear venting fireplace MUST BE in a vertical posi-
tion.
1. Apply the stove ce-
ment.
STARTING
COLLAR
2. Line up the internal
beads and rotate the
pipe sections clock-
wise until locked.
3. Lock the vent compo-
nents into place.
4. Check the seal on the
rope gasket.
STOVE
SEALANT
BEAD
3/8 INCH (9.5 mm)
FIRST
VENT
COMPONENT
1 INCH (25.4 mm)
Figure 15. Attaching the First Vent Component to
the Starting Collars
WARNING
A 3/8 INCH (9.5 MM) BEAD OF STOVE
CEMENT MUST BE PLACED AROUND
THE INNER PIPE FIREPLACE
STARTING COLLAR BEFORE
ATTACHING THE FIRST VENT
COMPONENT. FAILURE TO SEAL THIS
JOINT MAY CAUSE THE FIREPLACE TO
OPERATE IMPROPERLY. SEE THE
DIAGRAM .
17
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
ENSURE THAT THE FIBERGLASS
ROPE GASKET SUPPLIED WITH THE
FIREPLACE SEALS BETWEEN THE
FIRST VENT COMPONENT AND THE
OUTER FIREPLACE WRAP.
FOR MODEL 6000ARCH:
WARNNG: MAKE CERTAIN THAT THE
FIBERGLASS INSULATION BAND IS
PACKED INTO THE SPACE BETWEEN
THE 11-INCH DIAMETER TOP PIPE
HEAT SHIELD AND THE STARTER
PIPE. SEE FIGURE 16.
FIRST VENT
COMPONENT
FIBERGLASS
INSULATION
Figure 16.
2. Continue Adding Vent Components
To continue adding vent components in accordance
with the pre-planned vent system configuration:
• Ensure that each succeeding vent component is
securely fitted and locked into the preceding com-
ponent in the vent system.
90° elbows may be installed and rotated to any point
around the preceding component’s vertical axis. If an
elbow does not end up in a locked position with the
preceding component, attach with a minimum of two
(2) sheet metal screws.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Continue adding vent
components, locking
each succeeding
component into place.
Figure 17. Adding Venting Components
3. Install Support Brackets
For Horizontal Runs - The vent system must be
supported every five (5) feet of horizontal run by a
horizontal pipe support.
To install support brackets for horizontal runs:
• Place the pipe supports around the vent pipe.
• Nail the pipe supports to the framing members.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
For Vertical Runs - The vent system must be
supported every eight (8) feet (2.4 m) above the
fireplace flue outlet by wall brackets.
To install support brackets for vertical runs:
• Attach wall brackets to the vent pipe and secure
the wall bracket to the framing members with nails
or screws.
Use wall brackets to
support vertical runs
every 8 feet (2.4 m)
above the fireplace flue
outlet.
WALL
BRACKET
WALL
STUD
8 FT (2.8 m)
FLUE
OUTLET
1" MIN.
25.4 mm)
Figure 18. Installing Support Brackets
4. Install Firestops
For Horizontal Runs - Firestops are REQUIRED
on both sides of a combustible wall through which
the vent passes.
Model DVK-01TRD and SLK-01TRD do not need
an exterior firestop on an exterior combustible wall.
NOTE
To install firestops for horizontal runs that pass
through either interior or exterior walls:
• Cut a 12-inch by 12-inch (305 mm X 305 mm)
hole through the wall for D-series or a 10-inch by
10-inch (254mm X 254mm) hole for SL-D-series
pipe. The center of the hole is one (1) inch (25.4
mm) above the center of the horizontal vent pipe.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
• Position the firestops on both sides of the hole
previously cut and secure the firestops with nails or
screws.
• The heat shields of the firestops MUST BE placed
towards the top of the hole.
• Continue the vent run through the firestops.
1. Cut the hole through
the wall.
Figure 19. Hole and Vent Pipe
2. Position the firestops.
TRIM HEAT
HEAT SHIELD
3. Place the heat shield
to the top.
SHIELD IF TOO
LONG, ADD TO
SHIELD IF TOO
SHORT.
4. Continue the vent run.
EXTERIOR
FIRESTOP
INTERIOR
FIRESTOP
Figure 20. Heat Shield, Interior and Exterior
Firestops
For Vertical Runs - One ceiling firestop is
REQUIRED at the hole in each ceiling through which
the vent passes.
To install firestops for vertical runs that pass through
ceilings:
• Position a plumb bob directly over the center of the
vertical vent component.
• Mark the ceiling to establish the centerpoint of the
vent.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
• Drill a hole or drive a nail through this centerpoint.
• Check the floor above for any obstructions, such
as wiring or plumbing runs.
• Reposition the fireplace and vent system, if neces-
sary, to accommodate the ceiling joists and/or
obstructions.
• Cut an 11-inch X 11-inch (280 mm X 280 mm)for
D-series or 10-inch X 10-inch (254 mm X 254 mm)
for SLD-series pipe hole through the ceiling, using
the centerpoint previously marked.
• Frame the hole with framing lumber the same size
as the ceiling joists.
1. Cut the ceiling hole.
2. Add the new framing
members.
Figure 21. Hole and New Framing Members
If the area above the ceiling is NOT an attic, position
and secure the ceiling firestop on the ceiling side of
the previously cut and framed hole.
This shows a ceiling
installation.
JOIST
CEILING
NAILS (4 REQUIRED)
CEILING FIRESTOP
Figure 22. Ceiling Firestop (Ceiling Side)
22
Download from Www.Somanuals.com. All Manuals Search And Download.
If the area above the ceiling IS an attic, position and
secure the firestop on top of the previously framed
hole.
This shows an attic
installation.
NAILS (4 REQUIRED)
1. Keep insulation away
from the vent pipe at
least 1 inch (25 mm).
RAFTER
CEILING
CEILING FIRESTOP
Figure 23. Attic Firestop
C. Vent Termination
For Horizontal Terminations - To attach and secure
the termination to the last section of horizontal vent:
• Rotate and interlock the ends as described at the
beginning of the Installing Vent Components sec-
tion.
• The termination kit should pass through the wall
firestops from the exterior of the building.
• Adjust the termination cap to its final exterior posi-
tion on the building.
WARNING
THE TERMINATION CAP MUST BE
POSITIONED SO THAT THE ARROW IS
POINTING UP.
For roundcap termination kits:
• Use the exterior pipelock hole provided on the round
flange of the wall firestop to secure the vent pipe in
place.
For trapezoidal cap termination kits:
• Using screws, secure the cap to the exterior wall
through the flanges built into the cap.
• Use a high-temperature sealant or fiberglass rope
gasket to seal between the pipe and exterior
firestop.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
For round cap
termination:
1. Secure the pipe,
using the exterior
pipelock hole on the
round flange of the
wall firestop.
For trapezoidal
termination:
1. Screw the cap to the
exterior wall through
the flanges in the cap.
2. Seal the joint between
the pipe and the
exterior firestop.
Figure 24. Round and Trapezoid Termination
Caps
WARNING
THE BOTTOM OF THE VENT
TERMINATION CAP MUST BE A
MINIMUM OF 12 INCHES (305 MM)
ABOVE GROUND LEVEL (GRADE). THE
TOP OF THE CAP MUST BE A MINIMUM
OF 18 INCHES (457 MM) BELOW
COMBUSTIBLE MATERIAL, SUCH AS A
DECK, AND THE SIDE OF THE CAP
MUST BE A MINIMUM OF 6 INCHES (152
MM) AWAY FROM A PARALLEL OUTSIDE
WALL. VENTING TERMINALS SHALL
NOT BE RECESSED INTO A WALL OR
SIDING. SEE THE FOLLOWING
DIAGRAM FOR VENT TERMINATION
CLEARANCES.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
G
v
A
H
D
E
v
L
openable
fixed closed
C
B
v
B
v
v
v
B
F
M
v
I
v
X
B
J or K
A
V
=VENT TERMINAL
=AIR SUPPLY INLET
=AREA WHERE TERMINAL IS NOT PERMITTED
X
A
B
C
= 12"
= 12"
clearances above grade, veranda, porch, deck or balcony
clearances to window or door that may be opened
clearance to permanently closed window
= 9" (U.S.A.)
12" (Canada)
D
= 18"
vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 2 feet (60 cm)
from the center-line of the terminal
E
F
= 18"
= 9"
= 6"
clearance to unventilated soffit
clearance to outside corner
clearance to inside corner
G
H
= 3 ft. (Canada) not to be installed above a gas meter/regulator assembly
within 3 feet (90 cm) horizontally from the center-line of
the regulator
I
= 3 ft. (U.S.A.)
6 ft. (Canada)
clearance to service regulator vent outlet
J
K
= 9" (U.S.A.)
clearance to non-mechanical air supply inlet to building
12" (Canada) or the combustion air inlet to any other appliance
= 3 ft. (U.S.A.)
6 ft. (Canada)
clearance to a mechanical air supply inlet
*L = 7 ft.
clearance above paved sidewalk or a paved driveway
located on public property
**M = 18"
clearance under veranda, porch, deck or balcony
*
a vent shall not terminate directly above a sidewalk or paved driveway which is
located between two single family dwellings and serves both dwellings.
** only permitted if veranda, porch, deck or balcony is fully open on a minimum of
2 sides beneath the floor.
NOTE: Local Codes or Regulations may require different clearances.
Figure 25. Vent Termination Minimum Clearances
IF EXTERIOR WALLS ARE FINISHED WITH
VINYL SIDING, IT IS NECESSARY TO INSTALL
THE VINYL PROTECTOR KIT TO THE TOP OF
THE EXTERIOR FIRESTOP (FOR ALL ROUND
TERMINATION CAPS).
CAUTION
25
Download from Www.Somanuals.com. All Manuals Search And Download.
For Vertical Terminations - To locate the vent and
install the vent sections:
• Locate and mark the vent centerpoint on the
underside of the roof, and drive a nail through the
centerpoint.
• Make the outline of the roof hole around the
centerpoint nail.
• The size of the roof hole framing dimensions
depend on the pitch of the roof. There MUST BE a
1-inch (25.4 mm) clearance from the vertical vent
pipe to combustible materials.
• Mark the roof hole accordingly.
• Cover the opening of the installed vent pipes.
• Cut and frame the roof hole.
• Use framing lumber the same size as the roof
rafters and install the frame securely. Flashing
anchored to the frame must withstand heavy winds.
• Continue to install concentric vent sections up
through the roof hole (for inside vent installations) or
up past the roof line until you reach the appropriate
distance above the roof (for outside terminations).
WARNING
MAJOR U.S. BUILDING CODES
SPECIFY MINIMUM CHIMNEY AND/OR
VENT HEIGHT ABOVE THE ROOF TOP.
THESE MINIMUM HEIGHTS ARE
NECESSARY IN THE INTEREST OF
SAFETY. SEE THE FOLLOWING
DIAGRAM FOR MINIMUM HEIGHTS,
PROVIDED THE TERMINATION CAP IS
AT LEAST EIGHT (2) FEET FROM A
VERTICAL WALL AND 2-FEET BELOW
A HORIZONTAL OVERHANG.
NOTE
This also pertains to vertical vent systems installed
on the outside of the building.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
To seal the roof hole, and to divert rain and snow from
the vent system:
• Attach a flashing to the roof using nails, and use a
non-hardening mastic around the edges of the
flashing base where it meets the roof.
• Attach a storm collar over the flashing joint to form a
water-tight seal. Place non-hardening mastic
around the joint, between the storm collar and the
vertical pipe.
• Slide the termination cap over the end of the vent
pipe and rotate the pipe clockwise 1/4 turn.
1. Attach the flashing
and apply sealant
around the edges of
the flashing base.
TERMINATION
CAP
2. Attach the storm
collar over the flashing
joint and apply sealant
between the storm
collar and vertical
pipe.
Roof Pitch
H (min.) ft.
flat to 6/12
6/12 to 7/12
1.0
1.25
1.5
2.0
2.5
3.25
4.0
5.0
6.0
7.0
7.5
8.0
over 7/12 to 8/12
over 8/12 to 9/12
over 9/12 to 10/12
over 10/12 to 11/12
over 11/12 to 12/12
over 12/12 to 14/12
over 14/12 to 16/12
over 16/12 to 18/12
over 18/12 to 20/12
over 20/12 to 21/12
Figure 26. Minimum Height from Roof to Lowest
Discharge Opening
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 4
Positioning,
Leveling, and
Securing the
Fireplace
The diagram below shows how to properly position,
level, and secure the fireplace.
1. Place the fireplace
into position.
2. Level the fireplace
from side to side and
from front to back.
3. Shim the fireplace
with non-combus-
tible material, such
as sheet metal, as
necessary.
4. Secure the fireplace
to the framing by
nailing or screwing
Figure 27. Proper Positioning, Leveling, and
Securing of a Fireplace
Step 5
The Gas Control
Systems
WARNING
THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Two types of gas control systems are used with
these models: Standing Pilot Ignition and Direct
Spark Ignition (DSI). Model 6000XLT has Standing
Pilot Ignition only. Model 6000ARCH has DSI only.
Standing Pilot Ignition System
This system includes millivolt control valve, standing
pilot, thermopile/thermocouple flame sensor, and
piezo ignitor.
WARNING
110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE
IN A MILLIVOLT SYSTEM.
Direct Spark Ignition (DSI) System
This system includes a 24V control valve, electronic
module, transformer, and spark ignitor/flame sensor.
WARNING
110-120 VAC MUST BE WIRED TO THE
FIREPLACE JUNCTION BOX IN A DSI
SYSTEM.
WARNING
DIRECT VENT PROPANE MODELS
WITH DSI CONTROL SYSTEMS
CANNOT BE USED IN CANADA.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
DSI IGNITION
IGNITOR
STANDING PILOT
1/2" (13 mm)
3/8" (10 mm)
3/16" (5 mm)
Figure 28. Gas Controls Systems
Step 6
The Gas
Supply Line
NOTE: Have the gas supply line installed by a
qualified service technician in accordance with all
building codes.
NOTE: Before the first firing of the fireplace, the
gas supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly size
the gas supply line leading to the 1/2 inch
(13 mm) hook-up at the unit.
This gas fireplace is designed to accept a 1/2 inch
(13 mm) gas supply line.
To install the gas supply line:
• A listed 1/2 inch (13 mm) manual shut-off valve and a
listed flexible gas connector are connected to the 1/2
inch (13 mm) inlet of the control valve.
• A 1/8 inch (3 mm) N.P.T. plugged tapping, accessible
for test gauge connection, should be provided for in
the gas supply line leading to the unit’s shut-off valve.
• Locate the gas line access hole in the outer casing of
the fireplace.
• Open the fireplace lower grille, insert the gas supply
line through the gas line hole, and connect it to the
shut-off valve.
• When attaching the pipe, support the control so that
the lines are not bent or torn.
• After the gas line installation is complete, use a soap
solution to carefully check all gas connections for
leaks.
WARNING
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
• At the gas line access hole, use insulation to re-
pack the space around the gas pipe.
• Insert insulation from the outside of the fireplace
and pack the insulation tightly to totally seal be-
tween the pipe and the outer casing.
The gas line should be
installed by a qualified
service technician.
Figure 29. Gas Supply Line
Step 7
Gas Pressure
Requirements
Pressure requirements for Heat-N-Glo gas fireplaces
are shown in the table below.
Pressure
Natural Gas
Propane
Minimum
Inlet Pressure
5.0 inches
w.c.
11.0 inches
w.c.
Maximum Inlet
Gas Pressure
14.0 inches
w.c.
14.0 inches
w.c.
Manifold
Pressure
3.5 inches
w.c.
10.0 inches
w.c.
A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping
is provided on the outlet side of the gas control for a
test gauge connection to measure the manifold
pressure. To measure inlet pressure, provisions must
be made to attach a test gauge to a one-eighth (1/8)
inch (3 mm) N.P.T. plugged tapping immediately
upstream of the gas supply connection to the
fireplace.
The fireplace and its individual shut-off valve must be
disconnected from the gas supply piping system
during any pressure testing of the system at test
pressures in excess of one-half (1/2) psig (3.5 kPa).
The fireplace must be isolated from the gas supply
piping system by closing its individual shut-off valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than one-
half (1/2) psig (3.5 kPa).
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 8
Wiring the
Fireplace
NOTE: Electrical wiring must be installed by a
licensed electrician.
For Standing Pilot Ignition Wiring
Appliance Requirements
• This appliance DOES NOT require 110-120 VAC to
operate.
WARNING
DO NOT CONNECT 110-120 VAC TO THE
GAS CONTROL VALVE OR THE
APPLIANCE WILL MALFUNCTION AND
THE VALVE WILL BE DESTROYED.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the factory installed junction box
before the fireplace is permanently installed.
Remote Wall Switch
Position the remote wall switch in the desired position
on a wall. Run a maximum of 25 feet (7.8 m) or less
length of 18 A.W.G. minimum wire and connect it to
the fireplace ON/OFF switch pigtails.
WARNING
DO NOT CONNECT 110-120 VAC TO THE
REMOTE WALL SWITCH OR THE
CONTROL VALVE WILL BE
DESTROYED.
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
CAUTION
NOTE: MODEL SL-42DVT
DOES NOT HAVEAHI-TEMP
LIMIT SWITCH.
Figure 30. Standing Pilot Ignition Wiring Diagram
31
Download from Www.Somanuals.com. All Manuals Search And Download.
FAN WIRING DIAGRAM
VARIABLE SPEED CONTROL
BLK
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.
BLK
JUNCTION BOX
BLK
BLK
BLOWER RECEPTACLE
BLK
BLK
BLK
BLK
WHT
WHT
BLK
GROUND
TEMPERATURE
SENSOR SWITCH
BLOWER
GRN
BLK
WHT
110-120 VAC
TEMPERATURE
SENSOR SWITCH
JUNCTION
BOX
FAN
SPEED CONTROL
(RHEOSTAT)
Figure 31. Fan Wiring Diagram
For Direct Spark Ignition (DSI) Wiring
Appliance Requirements
This appliance requires that 110-120 VAC be wired to
the factory installed junction box. Maintain correct
polarity when wiring the junction box.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the fireplace junction box.
Remote Wall Switch
Position the remote wall switch in the desired position
on a wall. Run a maximum of 25 feet
(7.8 m) or less of 16 A.W.G. minimum wire and
connect it to the fireplace ON/OFF switch pigtails.
NOTE
Electrical wiring must be installed by a licensed
electrician.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: MODELS SL-42DVT &
6000ARCH DO NOT HAVEA
HI-TEMP. LIMIT SWITCH.
Figure 32. Direct Spark Ignition (DSI) Wiring Diagram
Step 9
Finishing
The following diagram shows the minimum vertical
and corresponding maximum horizontal dimensions
of fireplace mantels or other combustible projections
above the top front edge of the fireplace. See Figure 5
for other fireplace clearances.
12"
Only non-combustible
materials may be used
to cover the black
fireplace front.
11"
10"
9"
8"
7"
6"
11"
5"
10"
4"
9"
8"
7"
3"
6"
2"
1"
5"
4.5"
4"
3.5"
3"
1.5"
TOP FRONT EDGE
OF FIREPLACE
NOTE: ALL DIMENSIONS SHOWN
IN INCHES.
Figure 33. Minimum Vertical and Maximum
Horizontal Dimensions of
Combustibles above Fireplace
WARNING
WHEN FINISHING THE FIREPLACE,
NEVER OBSTRUCT OR MODIFY THE
AIR INLET/OUTLET GRILLES IN ANY
MANNER.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION
IF JOINTS BETWEEN THE FINISHED WALLS
AND THE FIREPLACE SURROUND (TOP AND
SIDES) ARE SEALED, A 300° F. MINIMUM
SEALANT MATERIAL MUST BE USED. THESE
JOINTS ARE NOT REQUIRED TO BE SEALED.
ONLY NON-COMBUSTIBLE MATERIAL (USING
300° F. MINIMUM ADHESIVE, IF NEEDED) CAN
BE APPLIED AS FACING TO THE FIREPLACE
SURROUND. SEE THE DIAGRAM SHOWN
BELOW.
1. Seal the joints.
2. Apply only non-
combustible facing
material to the fire-
place surround.
Figure 34. Sealant Material
Hearth Extensions
A hearth extension may be desirable for aesthetic
reasons. However, ANSI or CAN/CGA testing
standards do not require hearth extensions for gas
fireplace appliances.
Installing the Trim
Step 10
Combustible materials may be brought up to the
specified clearances on the side and top front edges of
the fireplace, but MUST NEVER overlap onto the front
face. The joints between the finished wall and the
fireplace top and sides can only be sealed with a 300°
F. (149° C) minimum sealant.
Installing Trim,
Logs, and
Ember Material
WARNING
WHEN FINISHING THE FIREPLACE,
NEVER OBSTRUCT OR MODIFY THE
AIR INLET/OUTLET GRILLES IN ANY
MANNER.
Install optional marble and brass trim surround kits as
desired. Marble, brass, brick, tile, or other non-
combustible materials can be used to cover up the
gap between the sheet rock and the fireplace.
Do not obstruct or modify the air inlet/outlet grilles.
When overlapping on both sides, leave enough space
so that the bottom grille can be lowered and the trim
door removed.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Positioning the Logs
If the gas logs have been factory installed they should
not need to be positioned.
If the logs have been packaged separately, refer to the
installation instructions that accompany the logs.
Save the log instructions with this manual.
If sooting occurs, the logs might need to be
repositioned slightly to avoid excessive flame
impingement.
Placing the Ember Material
Two separate bags of ember material are shipped with
this gas fireplace:
• The bag labeled Golden Ember (GE-93) is flame
colorant material.
• The bag labeled Glowing Ember (050-721) is
standard glowing ember material.
To place the ember material:
• Remove the wing nuts and glass clips or tension
springs around the glass door.
• Remove the glass door from the unit.
• Cover the top of the burner with a single layer of
ember material. Then sprinkle GE-93 on top of the
burner.
• Save the remaining ember materials for use during
fireplace servicing.
• Replace the glass door and a front trim door on the
unit (see Replacement Parts Section of the
manual.)
• Replace the wing nut, glass clips, and tension
springs.
• Hand tighten the wing nuts.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Lift the trim door up
and out of the unit.
2. Remove the wing
nuts, glass clips, and
the glass door from
the unit.
Figure 35. Glass Assembly
CAUTION
HAND TIGHTEN THE WING NUTS, BUT BE
CAREFUL NOT TO OVERTIGHTEN.
1. Place the ember
material onto the top
of the burner.
Figure 36. Placement of the Ember Material
CAUTION
IT IS STRONGLY RECOMMENDED THAT TRIM
DOORS WITH OPTIIONAL MESH SCREENS BE
INSTALLED ON PROPANE MODELS.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 11
Before Lighting
the Fireplace
Before lighting the fireplace, be sure to do the
following:
Review safety warnings and cautions
• Read the Safety and Warning Information section
at the beginning of this Installers Guide.
Double-check for gas leaks
• Before lighting the fireplace, double-check the unit
for possible gas leaks.
Double-check vent terminations and front grilles
for obstructions.
• Before lighting the fireplace, double-check the unit
for possible obstructions that could be blocking the
vent terminations or the front grilles.
Double-check for faulty components
• Any component that is found to be faulty MUST BE
replaced with an approved component. Tampering
with the fireplace components is DANGEROUS and
voids all warranties.
A small amount of air will be in the gas supply lines.
When first lighting the fireplace, it will take a few
minutes for the lines to purge themselves of this air.
Once the purging is complete, the fireplace will light
and will operate normally.
Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines, unless the
gas valve has been turned to the OFF position, in
which case the air would have to be purged.
Step 12
Lighting the
Fireplace
You’ve reviewed all safety warnings, you’ve checked
the fireplace for gas leaks, you know the vent system is
unobstructed, and you’ve checked for faulty
components. Now you’re ready to light the fireplace.
WARNING
PLEASE REFER TO THE USER’S
MANUAL FOR ALL CAUTIONS, SAFETY,
AND WARNING INFORMATION
PERTAINING TO THE LIGHTING AND
OPERATION OF THE FIREPLACE.
the
After the
LEAVE THIS INSTALLATION MANUAL
WITH THE APPLIANCE FOR FUTURE
REFERENCE.
Installation
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Fireplace
Maintenance
Although the frequency of your fireplace servicing and
maintenance will depend on use and the type of
installation, you should have a qualified service
technician perform an appliance check-up at the
beginning of each heating season. See the table below
for specific guidelines regarding each fireplace
maintenance task.
4
TURN OFF THE GAS BEFORE SERVICING
YOUR FIREPLACE.
IMPORTANT
Maintaining
and
Type of
Fireplace
Maintenance
Fireplace Maintenance Task To
Servicing
Your
Frequency
By
Be Completed
Replacing
Old Ember
Material
Once annually,
during the
Qualified
Service
Technician
Brush away loose ember material near
the burner. Replace old ember
Fireplace
annual check-up
material with new dime-size and -shape
pieces of Golden Ember (GE-93) and
Glowing Ember (050-721). New ember
material should be placed alternately on
top of the burnera layer of Golden
Ember, a layer of Glowing Ember,
and so on. Save the remaining ember
material and repeat this procedure at
your next servicing. For more
information, see Placing Ember
Material in this manual.
Cleaning
Burner
& Controls
Once annually
Periodically
Qualified
Service
Technician
Brush or vacuum the control
compartment, fireplace logs, and
burner areas surrounding the logs.
Checking
Flame
Patterns,
Qualified
Service
Technician
Make a visual check of your fireplaces
flame patterns. Make sure the flames
are steadynot lifting or floating. See
the picture in Figure 37. The flame ensor
(DSI) or thermopile/thermocouple
Flame Height
(standing pilot) tips should be covered
with flame. See the picture in Figure 38.
Checking
Vent System and at least
Before initial use
Qualified
Service
Inspect the external vent cap on a
regular basis to ensure that no debris is
interfering with the flow of air.
annually thereafter, Technician/
more frequently
if possible
Owner
Cleaning
Glass Door
As necessary
Homeowner Clean as necessary, particularly after
adding new ember (flame colorant)
material. Film deposits on the inside of
the glass door should be cleaned off
using a household glass cleaner.
NOTE: DO NOT handle or attempt to
clean the door when it is hot and
DO NOT use abrasive cleaners.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
MAKE SURE THE FLAMES
ARE STEADY—NOT
LIFTING OR FLOATING.
Figure 37. Burner Flame Patterns
STANDING PILOT
3/8" (10 mm)
DSI IGNITION
NOTE: FLAMES
TOO CLOSE TO
THE CERAMIC
INSULATORS CAN
CAUSE NUISANCE
LOCKOUTS AND
ELECTRODE
IGNITOR
1/2” (13mm)
FAILURE.
CERAMIC
INSULATOR
3/16" (5 mm)
39
Figure 38. Pilot/Ignitor Flame Patterns
Download from Www.Somanuals.com. All Manuals Search And Download.
All parts listed in this INSTALLERS GUIDE may be
ordered from an authorized dealer. When requesting
service or replacement parts for your fireplace, please
provide the model number and the serial number.
Standing Pilot Only
5
PART
PART DESCRIPTION
PART NUMBER
Valve LP (8000 & 6000’S)
Valve NG (8000 & 6000’S)
Valve LP (SL-42DVT)
SRV60-523
SRV60-522
SRV60-521
SRV60-520
Replacement
Parts and
VAlve NG (SL-42DVT)
Accessories
Piezo Ignitor
SRV60–513
Thermopile
SRV60–512
SRV446-511
Thermocouple
Pilot Orifice LP
Pilot Orifice NG
SRV446–517
SRV446–505
Pilot Assembly LP
Pilot Assembly NG
SRV446-511A
SRV446-510A
Pilot Tube
SRV446-301
Burner Tube
8000DVTFL
6000 Models
SL-42DVT
SRV410-302
SRV60-307
SRV486-300
40
Download from Www.Somanuals.com. All Manuals Search And Download.
DSI Ignition Only
(8000DVTFL, 6000DVTFL, 6000ARCH, SL-42DVT)
PART
PART DESCRIPTION
DSI Valve LP
PART NUMBER
SRV77–501
SRV77–500
DSI Valve NG
Transformer
SRV60–599
SRV420–592
SRV77–591
DSI Module
Electrode
Burner Tube
- 8000DVTFL
SRV410–303
SRV422–302
SRV486-302
- 6000DVTFL, 6000ARCH
- SL-42DVT
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Both Standing Pilot and DSI Ignition
PART
PART DESCRIPTION
PART NUMBER
High Temperature Limit Switch
SRV92–531
Burner
- SL-42DVT NG & LP
- 8000DVTFL NG
- 8000DVTFL LP
SRV486-176A
SRV410–326A
SRV410–325A
- 6000DVTFL NG, 6000XLT NG,
- 6000ARCH NG
- 6000DVTFL LP, 6000XLT LP,
- 6000ARCH LP
SRV422-176A
SRV422-175A
Burner Orifice
- 8000DVTFL NG
- 8000DVTFL LP
- 6000DVTFL NG
- 6000DVTFL LP
- 6000XLT NG
SRV67–800
SRV79–803
SRV79–831
SRV79-803
SRV420-800
SRV446-801
SRV57-800
SRV57-801
SRV79-831
SRV78-803
SRV60–525A
- 6000XLT LP
- 6000ARCH NG
- 6000ARCH LP
- SL-42DVT NG
- SL-42DVT LP
On/Off Rocker Switch
Glass Door Assembly
- 8000DVTFL
GLA–8FL
GLA–6DVT
GLA-6XLS
- 6000DVTFL
- 6000XLT
- 6000ARCH
GLA-6DV
- SL-42DVT
SRV486-600A
SRV60–135AX
Glass Clip Assembly
Wing Nut
SRV60–872
SRV79-001A
Glass Spring Fastener
GLASS SPECIFICATIONS: 8000DVTFL:
23” X 37 3/4”
TEMPERED
TEMPERED
CERAMIC
6000DVTFL:
6000XLT:
6000ARCH:
SL-42DVT:
20” X 34”
20” X 34”
20” X 34”
42
CERAMIC
23” X 37 3/4” TEMPERED
Download from Www.Somanuals.com. All Manuals Search And Download.
Both Standing Pilot and DSI Ignition (Cont.)
PART
PART DESCRIPTION
Trim Door
PART NUMBER
- 8000DVTFL
DF–8000
DF-6000
DF-36
- 6000 MODELS (MESH)
- 6000 MODELS (NO MESH)
- SL-42DVT
DF-8000-BK
Log Set Assembly
- 8000DVTFL
- 6000DVTFL
- 6000XLT
LOGS-8FL
LOGS-6FL
LOGS-CAMP
LOGS-SL42
- SL-42DVT
Bottom Right Refractory
SL-42DVT
SRV486-370
Bottom Left Refractory
SL-42DVT
SRV486-371
Grate Assembly SL-42DVT
SRV486-360A
Accessories
ACCESSORY
PART DESCRIPTION
PART NUMBER
Fan Kit
GFK-160A
GFK-270
Remote Control Kit
RCH-09A
RC-SMART
SMART-STAT
RC-MLT
Wall Switch Kit
- Off White
- White
WSK-21
WSK-21-W
Trim Door Mesh (SL-42DVT)
Refractory (SL-42DVT)
MESH-42
Nat. Gas
LPG
MET-REF-42
43