Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating,
inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual
near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and
the receipt in a safe and dry place for future reference.
using a generator indoors Can Kill Y
in minuteS.
Generator exhaust contains carbon
monoxide. this is a poison you cannot see
or smell.
ITEM 69728 / 69729
neveR use inside
a home or garage,
even iF doors and
windows are open.
Only use OutSiDe
and far away from
windows, doors,
and vents.
email our technical support at: [email protected]
When unpacking, make sure that the product is intact and undamaged.
If any generator parts are missing or broken, please call 1-800-444-
3353 as soon as possible. If any engine parts are missing or broken,
please call 1-800-520-0882 as soon as possible.
©
®
Copyright 2012 by Harbor Freight Tools . All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Read this material before using this product.
Failure to do so can result in serious injury.
Save thiS manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
Set up Precautions (cont.)
8. use only lubricants and fuel
10. Do not operate the Generator before grounding.
the Generator must be earth-grounded
in accordance with all relevant electrical
codes and standards before operation.
recommended in this manual.
9. improper connections to a building electrical
system can allow electrical current from the
generator to backfeed into the utility lines. Such
backfeed may electrocute utility company workers
or others who contact the lines during a power
outage, and the generator may explode, burn, or
cause fires when utility power is restored. Consult
the utility company and a qualified electrician if
intending to use the generator for back up power.
Operating Precautions
1.
CaRBOn mOnOxiDe hazaRD
using a generator indoors Can Kill
YOu in minuteS.
Generator exhaust contains carbon
monoxide. This is a poison you cannot
see or smell.
7. Fire Hazard! Do not fill gas tank while engine
is running. Do not operate if gasoline has been
spilled. Clean spilled gasoline before starting engine.
Do not operate near pilot light or open flame.
8. Do not touch engine during use. let engine
cool down before service or storage.
9. Never store fuel or other flammable
materials near the engine.
10. if the plugged in product operates abnormally
or unusually slow, immediately stop using the
generator as a power source. Always read and
adhere to the instruction manual of the product
to be powered, to make sure that it can be safely
and efficiently powered by a portable generator.
NEVER use inside a home or garage, EVEN IF doors
and windows are open.
11. Before connecting an appliance or power
cord to the generator: make sure that it is in
good working order. Faulty appliances or power
cords can create a potential for electrical shock.
12. Do not exceed the maximum power rating of
the generator. Make sure that the total electrical
rating of the all of the tools or appliances plugged
into the generator at the same time does not
exceed that of the generator. Check that the startup
surge will not be beyond the limit of the Generator.
Power levels between rated and maximum
Only use OUTSIDE and far away from windows,
doors, and vents.
2. never use a generator indoors, including in
garages, basements, crawl spaces and sheds.
Opening doors and windows or using fans will NOT
prevent carbon monoxide build up in the home.
may be used for no more than 30 minutes.
3. When using generators, keep them outdoors
and far away from open doors, windows,
and vents to avoid toxic levels of carbon
monoxide from building up indoors.
13. avoid substantially overloading which will
trip the circuit breaker. Exceeding the time
limit for maximum power operation or slightly
overloading the generator may not switch the
circuit breaker or circuit protector OFF, but will
shorten the service life of the generator.
4. if you start to feel sick, dizzy, or weak while
using a generator, get to fresh air right away.
The carbon monoxide from generators can
quickly lead to full incapacitation and death.
14. Do not attempt to connect or disconnect
load connections while standing in
water, or on wet or soggy ground.
5. Keep children away from the equipment,
especially while it is operating.
15. Do not touch electrically energized parts of
the Generator and interconnecting cables
or conductors with any part of the body, or
with any non-insulated conductive object.
6. Keep all spectators at least six feet
from the engine during operation.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 3
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Precautions (cont.)
16. Connect the Generator only to a load or
electrical system (120 volt or 240 volt) that is
compatible with the electrical characteristics
and rated capacities of the Generator.
29. Stay alert, watch what you are doing
and use common sense when operating
this piece of equipment. Do not use this
piece of equipment while tired or under the
influence of drugs, alcohol or medication.
17. insulate all connections and disconnected wires.
30. Dress properly. Do not wear loose clothing or
jewelry. Keep hair, clothing and gloves away
from moving parts. Loose clothes, jewelry or
long hair can be caught in moving parts.
18. Guard against electric shock. Prevent
body contact with grounded surfaces such as
pipes, radiators, ranges, and refrigerators.
19. Only use a suitable means of transport and
lifting devices with sufficient weight bearing
capacity when transporting the generator.
31. Parts, especially exhaust system components,
get very hot during use. Stay clear of hot parts.
32. Do not cover the generator or its
20. Secure the Generator on transport vehicles to
prevent the tool from rolling, slipping, and tilting.
engine during operation.
33. Keep the generator, its engine, and
21. industrial applications must
follow OSha requirements.
surrounding area clean at all times.
34. use the generator, accessories, etc., in
accordance with these instructions and in
the manner intended for the particular type of
equipment, taking into account the working
conditions and the work to be performed. Use
of the equipment for operations different from those
intended could result in a hazardous situation.
22. Do not leave the Generator unattended when it is
running. Turn off the Generator (and remove safety
keys, if available) before leaving the work area.
23. the Generator engine can produce high
noise levels. Prolonged exposure to noise levels
above 85 dBA is hazardous to hearing. Always
wear ear protection when operating or working
around the gas engine while it is operating.
35. Do not operate the generator with known
leaks in the engine’s fuel system.
24. Wear anSi-approved safety glasses and
36. this product contains or, when used,
produces a chemical known to the State of
California to cause cancer and birth defects
or other reproductive harm. (California
Health & Safety Code § 25249.5, et seq.)
hearing protection during use.
25. People with pacemakers should consult their
physician(s) before use. Electromagnetic
fields in close proximity to a heart pacemaker
could cause pacemaker interference or
37. When spills of fuel or oil occur, they must
be cleaned up immediately. Dispose of fluids
and cleaning materials as per any local, state, or
federal codes and regulations. Store oil rags in
a bottom-ventilated, covered, metal container.
pacemaker failure. Caution is necessary when
near the engine’s magneto or recoil starter.
26. use only accessories that are recommended
by harbor Freight tools for your model.
Accessories that may be suitable for one
piece of equipment may become hazardous
when used on another piece of equipment.
38. Keep hands and feet away from moving parts. Do
not reach over or across generator while operating.
39. Before use, check for misalignment or binding
of moving parts, breakage of parts, and any
other condition that may affect the generator’s
operation. if damaged, have the generator
serviced before using. Many accidents are
caused by poorly maintained equipment.
27. Do not operate in explosive atmospheres,
such as in the presence of flammable
liquids, gases, or dust. Gasoline-powered
engines may ignite the dust or fumes.
28. Keep grounded conductive objects, such as
tools, away from exposed, live electrical parts
and connections to avoid sparking or arcing.
These events could ignite fumes or vapors.
40. use the correct generator for the
application. Do not modify the generator or
its engine, and do not use the generator for
a purpose for which it is not intended.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 4
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Precautions
1. Before service, maintenance, or cleaning:
a. unplug all devices from the generator.
b. turn the engine switch to its “OFF” position.
c. allow the engine to completely cool.
7. Have the equipment serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the
equipment is maintained. Do not attempt any service
or maintenance procedures not explained in this
manual or any procedures that you are uncertain
about your ability to perform safely or correctly.
d. then, remove the spark plug
cap from the spark plug.
8. Store equipment out of the reach of children.
2. Keep all safety guards in place and in
proper working order. Safety guards include
muffler, air cleaner, mechanical guards,
and heat shields, among other guards.
9. Follow scheduled engine and
equipment maintenance.
Refueling:
3. Keep all electrical equipment clean and
dry. Replace any wiring where the insulation is
cracked, cut, abraded, or otherwise degraded.
Replace terminals that are worn, discolored, or
corroded. Keep terminals clean and tight.
1. Do not smoke, or allow sparks, flames,
or other sources of ignition around the
equipment, especially when refuelling.
2. Do not refill the fuel tank while the
4. Do not alter or adjust any part of the
equipment or its engine that is sealed by the
manufacturer or distributor. Only a qualified
service technician may adjust parts that may
increase or decrease governed engine speed.
engine is running or hot.
3. tO PRevent Fuel leaKaGe anD FiRe
hazaRD, Do not overfill with fuel. Fill with
fuel according to the Fuel level information
below the Specification chart for your model.
5. Wear anSi-approved safety goggles,
heavy-duty work gloves, and dust
mask/respirator during service.
4. Do not fill fuel tank to the top. Leave a little
room for the fuel to expand as needed.
6. maintain labels and nameplates on
the equipment. These carry important
information. If unreadable or missing, contact
Harbor Freight Tools for a replacement.
5. Refuel in a well-ventilated area only.
6. Wipe up any spilled fuel and allow excess
to evaporate before starting engine. to
prevent FiRe, do not start the engine
while the smell of fuel hangs in the air.
Save theSe
inStRuCtiOnS.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 5
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Functional Description
Specifications
120/240V~, 60Hz
3,200 Watts (4,000 max)
Rated Output
Phase
Single
Generator
Two 3-Prong, duplex NEMA #5-15 120V
One 4-Prong, NEMA #L14-30 twistlock 120V/240V
One DC Outlet 12VDC
Electrical Receptacle
Displacement
Engine Type
212cc
Horizontal Single Cylinder 4 stroke OHV
Forced air cooled
Cooling System
Type
87+ octane unleaded gasoline
4 Gallons (15L)
Fuel
Capacity
Engine
10W-30 above 32° F
5W-30 at 32° F or below
Type SAE
Engine Oil
Capacity
.6 Quart (.6L)
Run Time @ 50% load
Spark Plug
10 hr.
Torch® F6TC or equivalent / 0.7-0.8mm gap
70 dB
Operational Volume
Available accessories
Wheel kit (sold separately)
item 69728 - The emission control system for this Generator’s Engine is warranted for standards set by the U.S.
Environmental Protection Agency and by the California Air Resources Board (also known as CARB). For warranty
information, refer to the last pages of this manual.
item 69729 - The emission control system for this Generator’s Engine is warranted for standards set by the U.S.
Environmental Protection Agency. For warranty information, refer to the last pages of this manual.
Components and Controls
DC Receptacle
DC Circuit Breaker
Fuel Cap
AC Circuit Breaker
Fuel Valve
Choke
AC Receptacles
Air Filter
Frame
Ground Terminal
Power Switch
Starter
Handle
Low Oil Indicator
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 6
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Components and Controls (cont.)
On
The following are descriptions of the controls
on the power panel. Your generator has
sockets to power your products with circuit
breakers to protect the voltage flow.
OFF
3. Circuit Breakers: The circuit breaker protects the
Generator from overloading. The rating of the breaker
and the load it protects are marked near the breaker.
Should any of the Circuit Breakers trip, the Generator
will stop the electricity output. If this happens, unplug
all loads from the Generator. Allow the Generator to
cool down. Then, press the tripped Circuit Breaker,
restart the Engine, and re-attach loads.
i
O
1. engine Switch: Used to start and stop the Engine.
2. aC Receptacles: The Generator contains several
AC Receptacles to power tools and equipment.
4. DC Outlet Receptacle: 12 VDC outlet receptacle set
provides a power source for 12 volt DC items.
5. Grounding terminal: Prior to each use, set
up the ground wire (not included) connection
to the Grounding Terminal to properly ground
the Generator. See Set up instructions
to properly ground the Generator.
a. 3-Prong, duplex
120 volt aC Receptacle
(nema #5-15)
b. 4-Prong, twistlock
120/240 volt aC Receptacle
(nema #l14-30)
WaRninG! Connect tools and equipment
only to the AC Receptacle that is compatible with
the electrical characteristics and rated capacities
of the tools and equipment being used.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 7
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
initial tool Set up/assembly
At high altitudes, the engine’s carburetor, governor,
and any other parts that control the fuel-air ratio will
need to be adjusted by a qualified mechanic to allow
efficient high-altitude use and to prevent damage to the
engine and any other devices used with this product.
Read the entiRe imPORtant
SaFetY inFORmatiOn section at the
beginning of this manual including
all text under subheadings therein
before set up or use of this product.
CautiOn: This generator is not intended to power
sensitive electronic equipment without the addition of an
appropriate line conditioner and surge protector (both not
included). Sensitive electronic equipment includes,
but is not limited to, audio/video equipment, some
television sets, computers, and printers. Sensitive
electronic equipment should be operated on approved
inverter type generators or pure sine wave generators.
tO PRevent SeRiOuS injuRY:
Operate only with proper spark arrestor installed.
Operation of this equipment may create sparks that
can start fires around dry vegetation.
a spark arrestor may be required.
The operator should contact local fire
agencies for laws or regulations relating
to fire prevention requirements.
note: For additional information regarding the parts listed in the following pages,
refer to the Assembly Diagram near the end of this manual.
note: Wheel Kit, item # 68531 (sold separately) can be used with this generator.
Grounding
The Generator must be properly grounded before
use. Have the unit grounded by a qualified
electrician if you are not qualified to do so.
To ground the Generator, connect a #6 AWG
grounding wire (not included) from the Grounding
Terminal on the Control Panel to a grounding rod
(not included) that has been driven at least 24
inches deep into the earth. The grounding rod must
be an earth-driven copper or brass rod (electrode)
which can adequately ground the Generator.
Operating instructions
Read the entiRe imPORtant SaFetY inFORmatiOn section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
inspect tool before use, looking for damaged, loose, and missing parts.
if any problems are found, do not use tool until repaired.
Generator Pre-Start Checks
Inspect engine and equipment, looking for
damaged, loose, and missing parts before set
up and starting. If any problems are found,
do not use equipment until fixed properly.
2. Close the Fuel Valve.
3. Clean the top of the Dipstick and the area around it.
Remove the Dipstick by threading it counterclockwise,
and wipe it off with a clean lint free rag.
Checking and Filling engine Oil
CautiOn! Your Warranty is vOiD if the engine’s
crankcase is not properly filled with oil before each
use.
Full level
Full level
Before each use, check the oil level. Do not run the
engine with low or no engine oil.
Running the engine with no or low engine oil
Will permanently damage the engine.
4. Reinsert the Dipstick without threading it in and
remove it to check the oil level. The oil level
should be up to the full level as shown above.
1. Make sure the engine is stopped and is level.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 8
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Generator Pre-Start Checks (cont.)
5. If the oil level is at or below the low mark add the
appropriate type of oil until the oil level is at the
proper level. SAE 10W-30 oil is recommended
for general use. (The SAE Viscosity Grade chart
on page 15 in the Service section shows other
viscosities to use in different average temperatures.)
1. Clean the Fuel Cap and the area around it.
2. Unscrew and remove the Fuel Cap.
3. If needed, fill the Fuel Tank to about 1 inch
under the fill neck of the Fuel Tank with 87
octane or higher unleaded gasoline.
6. Thread the dipstick back in clockwise.
note: Do not use gasoline containing more than
10% ethanol (e10). Do not use e85 ethanol.
CautiOn! Do not run the engine with too little
oil. The engine will be permanently damaged.
note: Do not use gasoline that has been stored in a
metal fuel container or a dirty fuel container. it can
cause particles to enter the carburetor, effecting
engine performance and/or causing damage.
Checking and Filling Fuel
WaRninG! tO PRevent SeRiOuS
injuRY FROm FiRe:
4. Then, replace the Fuel Cap.
Fill the fuel tank in a well-ventilated area
away from ignition sources. If the engine is
hot from use, shut the engine off and wait
for it to cool before adding fuel.
5. Wipe up any spilled fuel and allow excess
to evaporate before starting engine.
to prevent FiRe, do not start the engine
while the smell of fuel hangs in the air.
Do not smoke.
using the Generator
Before Starting the Generator engine
Basic Generator use Procedure
See following pages for specific instructions
Before starting the engine:
a. Follow the Set up instructions
to prepare the Generator.
1. Check that the generator can handle the
wattage needed to power your products.
b. unplug all loads from the Generator.
c. inspect the Generator and engine.
d. Fill the engine with the proper amount
and type of both fuel and oil.
2. Start the Engine, and allow the Engine and
Generator to run and warm up for five minutes
after starting with no electrical load.
3. Plug in products.
4. When finished using the Generator,
disconnect all electrical loads.
note: Do not allow generator to run
out of fuel with loads attached.
5. Turn off the Engine.
6. Allow the Generator and its Engine to
completely cool. Then store the unit in a
clean, dry, safe location out of reach of
children and other unauthorized people.
imPORtant: After starting the engine, allow it to run at no load for five minutes
with no load after each start-up so that the engine can stabilize.
7. Break-in Period:
a. Breaking-in the engine will help to ensure proper equipment and engine operation.
b. The operational break-in period will last about 3 hours of use. During this period:
• Do not apply a heavy load to the equipment.
c. The maintenance break-in period will last about 20 hours of use. After this period:
• Change the engine oil.
Under normal operating conditions subsequent maintenance follows
the schedule explained in the SERVICE section.
For Pump technical questions, please call 1-800-444-3353.
Item 69728 / 69729
Page 9
For engine technical questions, please call 1-800-520-0882.
Download from Www.Somanuals.com. All Manuals Search And Download.
Starting the engine
1. To start a cold engine, move the Choke to the
CHOKE position.
To restart a warm engine, leave the Choke in the
RUN position.
2. Open the Fuel Valve.
i
ON
3. Turn the Engine Switch to ON.
O
4. Grip the Starter Handle of the Engine loosely and pull it
slowly several times to allow the gasoline to flow into the
Engine’s carburetor. Then pull the Starter Handle gently
until resistance is felt. Allow Cable to retract fully and
then pull it quickly. Repeat until the engine starts.
Note: Do not let the Starter Handle snap back against
the engine. Hold it as it recoils so it doesn’t hit
the engine.
5. Allow the Engine to run for several seconds.
Then, if the Choke lever is in the CHOKE position,
move the Choke Lever very slowly to its RUN position.
nOte: Moving the Choke Lever too fast could stall the engine.
imPORtant: Allow the engine to run at no load for five minutes with no
load after each start-up so that the engine can stabilize.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 10
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting electrical loads
Familiarize yourself with the engine controls, power panel and how to start the engine before using the generator.
Calculate the wattage of the products you will use with the generator and verify that the generator can handle the
total load.
WaRninG! Connect only properly wired plugs to the generator.
A plug that is spliced onto a different cord may be hazardous.
Only a qualified electrician should wire a plug onto a cord.
CautiOn Never exceed the rated capacity for this Generator,
as serious damage to the Generator and/or appliances, tools, and
equipment could result from an overload. Starting and running
wattage requirements should always be calculated when matching this
Generator’s wattage capacity to the appliance, tool, or equipment.
Use the DC12V Receptacle to power 12VDC equipment.
WaRninG! Do not charge batteries without a proper charge controller. Do not overcharge.
a. Connect the items that require the most wattage first.
b. Connect “inductive” load appliances, tools, and equipment next.
Inductive loads are small hand tools and some small appliances.
c. Connect any lights next.
d. Voltage sensitive appliances, tools, and equipment should be the last to be connected to the Generator.
Plug voltage sensitive items such as TV’s, DVD players, microwaves, and cordless telephones into a UL®
Listed voltage surge protector (not included). Then, connect the surge protector into the Generator.
imPORtant! Failure to connect and operate appliances, tools, and equipment in this sequence can cause
damage to the Generator, appliances, tools, and equipment and will void the Warranty of this Generator.
nOte: If Engine speed or voltage fluctuates with a load below the Generator’s rated watts, move the Engine Choke
Lever to the “halF-ChOKe” position.
IF anY CiRCuit BReaKeRS tRiP CheCK the FOllOWinG:
evenly distributed
1. Make sure that ALL circuit breakers are reset
over outlets:
before starting the generator again.
2. Adjust the plugs so the loads are
shared across outlet circuits.
to achieve rated output from the generator,
distribute loads over outlets.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 11
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Calculating total Wattage of Devices used with the Generator
Before using the Generator, check that the products
you want to plug into the unit are below the rated and
maximum wattage ratings of the Generator. Use the
Wattage Calculation Table below, and the watts listed
on your products, to help calculate multiple
wattage totals.
Wattage estimate Charts
note: Wattages listed below are estimates for that
type of equipment only. Check nameplate wattages
on all loads before connecting to Generator.
emeRGenCY
to use the table:
additional
Running
Watts
1. Add up the Running Watts for all items you
would like to use at any given time
2. Make sure that this total is under the
3200 rated wattage of the generator.
3. Find the single highest starting watts for
the selected items and add to the total.
4. Make sure that this total is under the 4000
maximum rated wattage of the generator.
5. Plug in and turn on products from largest wattage
to smallest.
Device
Start-up
Watts
1500
0
Refrigerator/Freezer
Radio
700
100
jOB Site
additional
Start-up
Watts
1000
Running
Watts
Device
Air Compressor - 1/2 HP
Table Saw - 10"
1000
1700
1200
600
1300
1200
600
0
Belt Sander - 3"
Hand Drill - 1/2"
Wattage Calculation table
Halogen Work Light
Recipricating Saw
1000
900
Running
Watts
900
equipment
ReCReatiOn
additional
Start-up
Watts
Running
Watts
Device
AM/FM Radio
Electric Grill
Inflator Pump
CD/DVD Player
Box Fan - 20"
Coffee Maker
100
1700
50
100
200
600
0
0
100
0
200
0
total Running Watts
(must be less than 3,200)
largest additional Start-up Watts
hOuSehOlD
total Startup Watts needed for all loads
(must be less than 4,000)
additional
Start-up
Watts
0
500
0
Running
Watts
Device
example
equipment
Running
Watts
Computer w/ Monitor
Electric Clothes Dryer
Electric Range
Electric Water Heater
Light Bulb - 100 watts
Microwave - 1000 watts
Sump Pump - 1/2 HP
Television
800
5500
2100
2000
100
Microwave (1,000 +200)
Television (400 + 0)
1,000
400
Box Fan (200 + 200)
Hand Drill (600 + 600)
200
600
0
0
1000
1000
400
200
1100
0
total Running Watts
(must be less than 3,200)
2,200
600
2,800
largest additional Start-up Watts
Washing Machine
Well Pump - 1/2 HP
1100
1000
1100
1000
total Startup Watts needed for all loads
(must be less than 4,000)
laWn & GaRDen
A generator that is rated more than the minimum
required peak watts will last much longer than a
generator that only supplies the exact watts needed.
additional
Start-up
Watts
400
Running
Watts
Device
Hedge Trimmer
Pressure Washer
Lawn Mower
Edger
400
to Calculate Wattage
Volts and amps can be multiplied together to get watts (volts x
amps = watts).
1200
1200
1000
1200
1200
1000
to Calculate additional Start-up Watts
(if they are not listed)
heatinG & COOlinG
For equipment with a motor: Use the rated watts
amount as an estimate of additional Start-up Watts.
additional
Start-up
Watts
1500
Running
Watts
Device
For most lights or heaters:
there are no additional start-up watts.
Central AC - 10,000 BTU
Furnace Fan - 1/2 HP
Space Heater
1500
900
1800
1200
1400
0
600
Window AC - 10,000 BTU
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 12
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Stopping the engine in an emergency
To stop the engine in an emergency,
turn the Engine Switch off.
i
nOtiCe: Generator shut-off under load may damage
the generator and attached equipment.
O
OFF
Stopping the engine under normal Conditions
1. Before turning off the Engine,
turn off all electrical loads,
then unplug them.
2. Turn the Engine Switch off.
i
O
OFF
3. Close the Fuel Valve.
For Pump technical questions, please call 1-800-444-3353.
Item 69728 / 69729
Page 13
For engine technical questions, please call 1-800-520-0882.
Download from Www.Somanuals.com. All Manuals Search And Download.
user-maintenance instructions
Procedures not specifically explained in this manual must
be performed only by a qualified technician.
tO PRevent SeRiOuS injuRY FROm aCCiDental OPeRatiOn:
turn the Power Switch of the equipment to its “OFF” position, wait for the engine to cool, and disconnect
the spark plug cap before performing any inspection, maintenance, or cleaning procedures.
tO PRevent SeRiOuS injuRY FROm equiPment FailuRe:
Do not use damaged equipment. if abnormal noise, vibration, or excess
smoking occurs, have the problem corrected before further use.
Follow all service instructions in this manual. the engine may fail critically if not serviced properly.
many maintenance procedures, including any not detailed in this manual, will need to be
performed by a qualified technician for safety. If you have any doubts about your ability to safely
service the equipment or engine, have a qualified technician service the equipment instead.
Cleaning, maintenance, and lubrication
note: This maintenance schedule is intended solely as a general guide. If performance decreases or if
equipment operates unusually, check systems immediately. The maintenance needs of each piece of equipment
will differ depending on factors such as duty cycle, temperature, air quality, fuel quality, and other factors.
note: The following procedures are in addition to the regular checks and maintenance
explained as part of the regular operation of the engine and equipment.
monthly or
every 20
hr. of use
Yearly or
every 300
hr. of use
Before
each use
every 3 mo. or every 6 mo. or
50 hr. of use 100 hr. of use
every
2 Years
Procedure
Brush off outside of engine
Check engine oil level
Check air cleaner
Check deposit cup
Change engine oil
Clean/replace air cleaner
*
Check and clean spark plug
1. Check/adjust idle speed
2. Check/adjust valve clearance
3. Clean fuel tank, strainer
and carburetor
**
**
**
4. Clean carbon build-up from
combustion chamber
Replace fuel line if necessary
*Service more frequently when used in dusty areas.
**These items should be serviced by a qualified technician.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 14
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Checking and Filling Fuel
note: Do not use gasoline containing more than
10% ethanol (e10). Do not use e85 ethanol.
WaRninG! tO PRevent SeRiOuS
injuRY FROm FiRe:
Fill the fuel tank in a well-ventilated area
away from ignition sources. If the engine is
hot from use, shut the engine off and wait
for it to cool before adding fuel.
note: Do not use gasoline that has been stored in a
metal fuel container or a dirty fuel container. it can
cause particles to enter the carburetor, effecting
engine performance and/or causing damage.
Do not smoke.
4. Replace the Fuel Cap.
1. Clean the Fuel Cap and the area around it.
2. Unscrew and remove the Fuel Cap.
5. Wipe up any spilled fuel and allow excess
to evaporate before starting engine. To
prevent FIRE, do not start the engine while
the smell of fuel hangs in the air.
3. If needed, fill the Fuel Tank with 87
octane or higher unleaded gasoline.
engine Oil Change
CautiOn! Oil is very hot during operation and can
cause burns. Wait for engine to cool before changing oil.
Full level
1. Make sure the engine is stopped and is level.
2. Close the Fuel Valve.
Full level
3. Place a drain pan (not included) underneath
the crankcase’s drain plug.
7. Add the appropriate type of oil until the
oil level is at the full level. SAE 10W-30
oil is recommended for general use.
4. Remove the drain plug and, if possible,
tilt the crankcase slightly to help drain
the oil out. Recycle used oil.
note: Do not thread the dipstick in
when checking the oil level.
5. Replace the drain plug and tighten it.
The SAE Viscosity Grade chart shows other
viscosities to use in different average temperatures.
6. Clean the top of the Dipstick and the area around it.
Remove the Dipstick by threading it counterclockwise,
and wipe it off with a clean lint free rag.
Sae viscosity Grades
30
10W-30
5W-30
-20
0
20
40
60
80
100°F
average outdoor temperature
8. Thread the dipstick back in clockwise.
CautiOn! Do not run the engine with too little
oil. The engine will be permanently damaged.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 15
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
air Filter element maintenance
1. Remove the air filter cover and the
air filter elements and check for dirt.
Clean or replace as described below.
• For foam filter elements:
Wash the element in warm water and
mild detergent several times. Rinse.
Squeeze out excess water and allow it to dry
completely. Soak the filter in lightweight oil
briefly, then squeeze out the excess oil.
2. Cleaning:
• For “paper” filter elements:
To prevent injury from dust and debris,
wear ANSI-approved safety goggles,
NIOSH-approved dust mask/respirator, and
heavy-duty work gloves. In a well-ventilated
area away from bystanders, use pressurized
air to blow dust out of the air filter. If this does
not get the filter clean, replace it.
3. Install the new filter or the cleaned filter.
Secure the Air Cleaner Cover before use.
Spark Plug maintenance
1. Disconnect spark plug cap from end of plug.
Clean out debris from around spark plug.
4. When installing a new spark plug, adjust
the plug’s gap to the specification on the
Specifications chart. Do not pry against the
electrode, the spark plug can be damaged.
2. Using a spark plug
Spark Plug
wrench, remove
the spark plug.
5. Install the new spark plug or the cleaned spark plug
into the engine. Gasket-style: Finger-tighten until the
gasket contacts the cylinder head, then about 1/2-2/3
turn more.
3. Inspect the spark
plug:
If the electrode is
oily, clean it using
a clean, dry rag. If
the electrode has
deposits on it, polish
Non-gasket-style: Finger-tighten until the plug
contacts the head, then about 1/16 turn more.
Cylinder
assembly
nOtiCe: Tighten the spark plug properly.
If loose, the spark plug will cause the engine
to overheat. If overtightened, the threads
in the engine block will be damaged.
it using emery paper. If the white insulator is cracked
or chipped, the spark plug needs to be replaced.
6. Apply spark plug boot protector to the end of the
spark plug and reattach the wire securely.
nOtiCe: Using an incorrect spark plug may
damage the engine. See the Specifications chart
for your Generator for the type and gap required.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 16
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Storage
When the equipment is to remain idle for longer than
20 days, prepare the engine for storage as follows:
c. Open the fuel valve. After all fuel has
drained, reinstall the drain bolt and sediment
cup (if equipped). Tighten securely.
1. CleaninG:
Wait for engine to cool, then clean engine with
dry cloth. nOtiCe: Do not clean using water.
The water will gradually enter the engine and cause
rust damage.
Apply a thin coat of rust preventive
oil to all metal parts.
3. luBRiCatiOn:
a. Change engine oil.
b. Clean out area around spark plug. Remove
spark plug and pour one tablespoon of engine
oil into cylinder through spark plug hole.
c. Replace spark plug, but leave spark
plug cap disconnected.
2. Fuel:
d. Pull Starter Handle to distribute oil in cylinder.
Stop after one or two revolutions when you
feel the piston start the compression stroke
(when you start to feel resistance).
WaRninG! tO PRevent SeRiOuS
injuRY FROm FiRe:
Drain the fuel tank in a well-ventilated area
away from ignition sources. If the engine is
hot from use, shut the engine off and wait
for it to cool before draining fuel.
Do not smoke.
4. BatteRY:
Disconnect battery cables (if equipped).
Recharge batteries monthly while in storage.
air Filter assembly
5. StORaGe aRea:
Cover and store in a dry, level, well-ventilated
area out of reach of children. Storage area
should also be away from ignition sources, such
as water heaters, clothes dryers, and furnaces.
Cylinder
assembly
6. aFteR StORaGe:
Before starting the engine after storage, keep in
mind that untreated gasoline will deteriorate quickly.
Drain the fuel tank and change to fresh fuel
if untreated gasoline has been sitting for
a month, if treated gasoline has been sitting
beyond the fuel stabilizer’s recommended
time period, or if the engine does not start.
Drain Plug
a. Place a funnel leading to a proper gasoline
container below the carburetor.
b. Remove the drain bolt from the bottom of the
carburetor bowl and allow the fuel to drain.
If present on your model, remove the small
sediment cup next to the bowl and allow
the fuel to drain from there as well.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 17
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
troubleshooting
Problem
Possible Causes
Probable Solutions
Engine will not start
FUEL RELATED:
FUEL RELATED:
1. No fuel in tank or fuel valve closed.
1. Fill fuel tank and open fuel valve.
2. Choke not in CHOKE position, cold engine. 2. Move Choke to CHOKE position.
3. Gasoline with more than 10% ethanol used. 3. Clean out ethanol rich gasoline from fuel
(E15, E20, E85, etc.)
system. Replace components damaged
by ethanol. Use fresh 87+ octane
unleaded gasoline only.
Do not use gasoline with more than
10% ethanol (e15, e20, e85, etc.).
4. Low quality or deteriorated, old gasoline.
4. Use fresh 87+ octane unleaded gasoline.
Do not use gasoline with more than
10% ethanol (e15, e20, e85, etc.).
5. Carburetor not primed.
6. Dirty fuel passageways.
5. Pull on Starter Handle to prime.
6. Clean out passageways using fuel additive.
Heavy deposits may require further cleaning.
7. Carburetor needle stuck.
Fuel can be smelled in the air.
7. Gently tap side of carburetor float
chamber with screwdriver handle.
8. Too much fuel in chamber. This can be
caused by the carburetor needle sticking.
8. Turn Choke to RUN position. Remove spark
plug and pull the start handle several times
to air out the chamber. Reinstall spark
plug and set Choke to CHOKE position.
9. Clogged Fuel Filter.
9. Replace Fuel Filter.
IGNITION (SPARK) RELATED:
1. Spark plug cap not connected securely.
2. Spark plug electrode wet or dirty.
3. Incorrect spark plug gap.
IGNITION (SPARK) RELATED:
1. Connect spark plug cap properly.
2. Clean spark plug.
3. Correct spark plug gap.
4. Replace spark plug cap.
4. Spark plug cap broken.
5. Circuit breaker tripped (electric
start models only).
5. Reset circuit breaker. Check wiring and
starter motor if breaker continues to trip.
6. Incorrect spark timing or
faulty ignition system.
6. Have qualified technician diagnose/
repair ignition system.
COMPRESSION RELATED:
COMPRESSION RELATED:
1. Cylinder not lubricated. Problem after long 1. Pour tablespoon of oil into spark
storage periods.
plug hole. Crank engine a few
times and try to start again.
2. Loose or broken spark plug. (Hissing noise 2. Tighten spark plug. If that does not work,
will occur when trying to start.)
replace spark plug. If problem persists,
may have head gasket problem, see #3.
3. Loose cylinder head or damaged
head gasket. (Hissing noise will
occur when trying to start.)
3. Tighten head. If that does not remedy
problem, replace head gasket.
4. Engine valves or tappets
mis-adjusted or stuck.
4. Have qualified technician diagnose/
repair ignition system.
Follow all safety precautions whenever diagnosing or servicing the equipment or engine.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 18
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
troubleshooting (cont.)
Problem
Possible Causes
Probable Solutions
1. Spark plug cap loose.
1. Check wire connections.
2. Incorrect spark plug gap or
damaged spark plug.
2. Re-gap or replace spark plug.
3. Defective spark plug cap.
4. Old or low quality gasoline.
3. Replace spark plug cap.
4. Use only fresh 87+ octane unleaded gasoline.
Do not use gasoline with more than
10% ethanol (e15, e20, e85, etc.).
Engine misfires
5. Incorrect compression.
1. Low oil shutdown.
5. Diagnose and repair compression.
(Use engine will not start:
COmPReSSiOn RelateD section.)
1. Fill engine oil to proper level.
Check engine oil before EVERY use.
2. Fuel tank empty or full of impure or low
quality gasoline.
2. Fill fuel tank with fresh 87+ octane
unleaded gasoline.
Do not use gasoline with more than
10% ethanol (e15, e20, e85, etc.).
Engine stops
suddenly
3. Defective fuel tank cap creating
3. Test/replace fuel tank cap.
vacuum, preventing proper fuel flow.
4. Faulty magneto.
4. Have qualified technician service magneto.
5. Disconnected or improperly
connected spark plug cap.
5. Secure spark plug cap.
1. Dirty air filter.
1. Clean or replace element.
Engine stops when
under heavy load
2. Engine running cold.
2. Allow engine to warm up prior
to operating equipment.
1. Old or low quality gasoline.
1. Fill fuel tank with fresh 87+ octane
unleaded gasoline.
Do not use gasoline with more than
10% ethanol (e15, e20, e85, etc.).
Engine knocks
2. Engine overloaded.
2. Do not exceed equipment’s load rating.
3. Incorrect spark timing, deposit buildup,
worn engine, or other mechanical problems.
3. Have qualified technician diagnose
and service engine.
1. Impure or low quality gasoline.
1. Fill fuel tank with fresh 87+ octane
unleaded gasoline.
Do not use gasoline with more than
10% ethanol (e15, e20, e85, etc.).
2. Engine too cold.
2. Use cold weather fuel and oil
Engine backfires
additives to prevent backfiring.
3. Intake valve stuck or overheated engine.
3. Have qualified technician diagnose
and service engine.
4. Incorrect timing.
4. Check engine timing.
1. Product not plugged in properly.
1. Turn off and unplug the product, then
plug it back in again and turn on.
Product doesn’t
have power
2. Circuit Breaker tripped.
2. Turn off and unplug product, Reset Circuit
Breaker. Plug in product and turn on.
3. Product needs service.
1. Problem with appliance.
3. Have product repaired.
1. Immediately unplug appliance. Have
appliance repaired by a qualified
technician, or replace appliance.
Product begins to
operate abnormally
2. Rated load capacity exceeded.
2. Lower the number of items plugged into the
generator to stay within the rated capacity,
or use a more powerful generator.
Follow all safety precautions whenever diagnosing or servicing the equipment or engine.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 19
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts list and Diagram
PleaSe ReaD the FOllOWinG CaReFullY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR ExPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Parts list
Part
Description
qty
1
1
1
1
4
2
2
2
4
1
1
1
1
1
1
2
2
1
1
3
1
2
1
1
1
1
2
1
6
1
1
2
1
1
1
1
1
1
1
1
1
1
1
Part
Description
qty
1
2
2
1
2
2
2
2
2
1
3
1
1
1
1
4
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
2
3
4
5
6
7
8
9
Gasket, Cylinder Head
44 Guide, Seal
Cover Subassembly, Cylinder Head
Gasket, Cylinder Head Cover
Tube, Breather
Bolt, Cylinder Head
Stud
45 Tappet, Valve
46 Lifter, Valve
47 Plate Subassembly, Lifter Stopper
48 Bolt, Valve Adjusting
49 Rocker, Valve
50 Valve Adjusting Nut
51 Nut, Valve Lock
52 Spring, Valve
53 Starter Assy, Recoil
54 Bolt
Stud
Pin
Bolt, Cylinder Head
10 Plug, Spark
11 Head Subassembly, Cylinder
12 Crankcase Subassembly.
13 Sensor, Engine Oil
14 Gear Assy, Governor
15 Arm, Governor
16 Bolt, Drain Plug
17 Washer
18 Bearing
19 Seal, Oil
20 Washer
21 Pin
22 Bolt
23 Cover, Crankcase
24 Bearing
25 Seal, Oil
26 Gasket, Crankcase
27 Pin
28 Dipstick Subassembly, Oil
29 Bolt
30 Crankshaft Assy.
31 Ring Set, Oil
32 Clip, Piston Pin
33 Piston
55 Shroud
56 Shroud, Cylinder Body
57 Shield,Lower
58 Protector, Oil
59 Bolt
60 Bolt
61 Bolt
62 Collar
63 Bolt
64 Carburetor Assy.
65 Gasket, Air Cleaner
66 Gasket, Carburetor
67 Plate, Carburetor Insulator
68 Gasket, Carburetor Insulator
69 Nut
70 Cleaner, Air
71 Nut, Flywheel
72 Pulley,Starter
73 Impeller
74 Flywheel Subassembly
75 Bolt
76 Coil, Ignition
77 Support Subassembly, Governor
78 Nut
79 Bolt, Governor Support
80 Spring, Governor
81 Rod, Governor
82 Spring, Throttle Valve Returning
83 Control Assy, Throttle
84 Bolt
34 Pin, Piston
35 Rod, Connecting
36 Ring, The First
37 Ring, The Second
38 Camshaft Assy.
39 Valve, Exhaust
40 Valve, Intake
41 Seat, Valve Spring
42 Exhaust Valve Retainer
43 Rotator, Valve
85 Muffler Assy.
86 Cover, Muffler Outer
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 20
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts list (cont.)
Part
Description
qty
1
1
2
5
1
2
2
1
4
4
4
4
1
1
2
1
1
2
1
1
8
2
2
4
4
4
2
1
1
2
1
2
1
1
1
1
Part
Description
qty
1
1
1
4
1
1
1
2
1
1
1
2
1
1
87 Bracket,Muffler
123 Panel Subassembly, Control
124 Motor Assy.
88 Bolt
89 Bolt
90 Bolt
91 Gasket, Exhaust Outlet
92 Bolt
93 Nut
94 Tank, Fuel
95 Sleeve, Fuel Tank Rubber
96 Bush
97 Washer
125 Bracket, Motor
126 Stator Bolt
127 Washer
128 Rotor Bolt
129 Regulator, Voltage
130 Bolt
131 Brush Subassembly, Carbon
132 Bolt
133 Cover, Motor Tail
134 Bolt
135 Band
136 Bolt
98 Bolt
99 Cover, Fuel Tank
100 Fuel Strainer
101 Screw
the following parts are only on
item 69728 (ePa/CaRB version)
137 Valve, One Way
138 Clamp
102 Leveler Assy, Oil
103 Cock Assy, Fuel
104 Collar
105 Tube, Fuel
106 Frame Assy, Engine
107 Nut
108 Cushion, Engine Frame Right
109 Cushion, Engine Frame
110 Nut
111 Seat, Engine Frame Shock Absorption
112 Bolt
1
1
1
1
1
1
1
1
2
139 Clamp
140 Hose, Air Cleaner Rubber
141 Hose, Fuel Steam Rubber
142 Clamp
143 Clamp
144 Collector, Fuel Steam
145 Bolt
the following parts are only on
item 69729 (ePa version)
137A Valve, One Way
138A Gasket, Rubber Flat
139A Cover
140A Clamp
141A Hose, Fuel Steam Rubber
142A Clamp
113 Bolt
114 Crosspiece Subassembly
115 Socket Subassembly, Power Supply
116 Socket Subassembly, Power Supply
117 Protector, Overcurrent
118 Protector, Overcurrent
119 Terminal Subassembly, Grounding
120 Socket Subassembly, DC
121 Switch Subassembly
122 Case, Panel Rear
1
2
1
1
1
1
1
2
143A Clip
144A Bolt
Record Product's Serial number here:
note: If product has no serial number, record month and year of purchase instead.
note: Some parts are listed and shown for illustration purposes only, and
are not available individually as replacement parts.
For Pump technical questions, please call 1-800-444-3353.
Item 69728 / 69729
Page 21
For engine technical questions, please call 1-800-520-0882.
Download from Www.Somanuals.com. All Manuals Search And Download.
assembly Diagram
note: Parts 137A - 144A are only on
Item 69728 (EPA/Carb version)
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 22
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards,
and warrants to the original purchaser that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly,
to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries
to persons or property, or for incidental, contingent, special or consequential damages arising from the use of
our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation of exclusion may not apply to you. THIS WARRANTY IS ExPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, ExPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges
prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the product at our election or we may
elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will
return repaired products at our expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
emission Control System Warranty
For item 69728 (ePa/CaRB version)
California and united States emission Control Defects Warranty Statement
The California Air Resources Board (herein CARB), the United States Environmental Protection Agency (herein EPA), and Harbor Freight Tools
(herein HFT) are pleased to explain the emission control system warranty on your 1995 and later Small Off-Road Engine (herein engine). In California,
the engine must be designed, built and equipped to meet the State’s stringent anti-smog standards. Elsewhere within the United States, new off-road,
spark-ignition engines certified for model year 1997 and later, must meet similar standards set forth by the EPA. HFT must warrant the emission control
system on your engine for the periods of time described below, provided there has been no abuse, neglect or improper maintenance of your engine.
Your emission control system may include parts such as the carburetor or fuel-injection system, and the ignition system. Also included may be
hoses, belts, connectors and other emission-related assemblies.
Where a warrantable condition exists, HFT will repair your engine at no cost to you including diagnosis, parts and labor.
For item 69729 (ePa version)
united States emission Control Defects Warranty Statement
The United States Environmental Protection Agency (herein EPA) and Harbor Freight Tools (herein HFT) are pleased to explain the emission
control system warranty on your 1997 and later Small Off-Road Engine (herein engine). Within the United States, new off-road, spark-ignition en-
gines certified for model year 1997 and later, must be designed, built and equipped to meet the stringent anti-smog standards set forth by the EPA.
HFT must warrant the emission control system on your engine for the periods of time described below, provided there has been no abuse, neglect
or improper maintenance of your engine.
Your emission control system may include parts such as the carburetor or fuel-injection system, and the ignition system. Also included may be
hoses, belts, connectors and other emission-related assemblies.
Where a warrantable condition exists, HFT will repair your engine at no cost to you including diagnosis, parts and labor.
For both item numbers
manufacturer’s Warranty Coverage
The 1997 and later engines are warranted for two (2) years. If any emission-related part on your engine is defective, the part will be repaired or
replaced by HFT.
harbor Freight tools emission Control Defects Warranty Coverage
Engines are warranted for a period of two (2) years relative to emission control parts defects, subject to the provisions set forth below. If any
emission related part on your engine is defective, the part will be repaired or replaced by HFT.
Owner’s Warranty Responsibilities
• As the engine owner, you are responsible for the performance of the required maintenance listed in your Owner’s Manual. HFT recommends
that you retain all receipts covering maintenance on your engine, but HFT cannot deny warranty solely for the lack of receipts or for your failure
to ensure the performance of all scheduled maintenance.
• As the engine owner, you should, however, be aware that HFT may deny you warranty coverage if your engine or a part has failed due to abuse,
neglect, improper maintenance, or unapproved modifications.
• You are responsible for shipping your engine to a HFT warranty station as soon as a problem exists. Contact the HFT Customer Service depart-
ment at the number below to make shipping arrangements. The warranty repairs should be completed in a reasonable amount of time, not to
exceed 30 days.
For Pump technical questions, please call 1-800-444-3353.
For engine technical questions, please call 1-800-520-0882.
Page 23
Item 69728 / 69729
Download from Www.Somanuals.com. All Manuals Search And Download.
If you have any questions regarding your warranty rights and responsibilities, you should contact the Harbor Freight Tools Customer Service
Department at 1-800-444-3353.
harbor Freight tools emission Control Defects Warranty Provisions
1. Length of Coverage
HFT warrants to a first retail purchaser and each subsequent purchaser that the engine is free from defects in materials and workmanship that
cause the failure of warranted parts for a period of two (2) years after the date of delivery to the first retail purchaser.
2. No Charge Repair or Replacement
Repair or replacement of any warranted part will be performed at no charge to the owner if the work is performed through a warranty station
authorized by HFT. For emissions warranty service, contact the HFT Customer Service Department at 1-800-444-3353.
3. Consequential Damages Coverage
Coverage under this warranty shall also extend to the failure of any engine components caused by the failure of any warranted part while it is
still covered under this warranty.
4. Coverage Exclusions
Warranty claims shall be filed in accordance with the provisions of the HFT warranty policy explained in the box at the top of the previous page.
HFT shall not be liable for any loss of use of the engine, for any alternative usage, for any damage to goods, loss of time, or inconvenience. War-
ranty coverage shall also be excluded for any part which fails, malfunctions, or is damaged due to failure to follow the maintenance and operating
instructions set forth in the Owner’s Manual including, but not limited to:
a) Use of parts which are not authorized by HFT
b) Improper installation, adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center
c) Failure to follow recommendations on fuel use contained in the Owner’s Manual
d) Improper or inadequate maintenance of any warranted parts
e) Repairs performed outside of the authorized warranty service dealers
f)
Alterations by changing, adding to or removing parts from the engine.
5. Service and Maintenance
Component parts which are not scheduled for replacement as required maintenance or are scheduled only for regular inspection to the effect
of “repair or replace as necessary” are warranted for the warranty period. Any warranted part which is scheduled for replacement as required
maintenance is warranted for the period of time up to the first scheduled replacement point for that part. Any replacement part, provided it is
equivalent in durability and performance, may be used in performance of maintenance or repairs. The owner is responsible for commissioning a
qualified technician/mechanic to perform all required maintenance, as outlined in the Inspection, Cleaning, and Maintenance section in this manual.
6. Warranted Parts
1) Fuel metering System
i)
Carburetor and its internal parts.
ii) Fuel pump (if so equipped).
iii) Cold start enrichment system.
2) air induction System
i)
Intake pipe/manifold.
ii) Air cleaner.
3) ignition System
i)
Spark plug.
ii) Magneto ignition system.
4) Catalyst System (if so equipped)
i)
Exhaust pipe stud.
ii) Muffler.
iii) Catalytic converter (if so equipped).
5) miscellaneous items used in above Systems
i)
Vacuum, temperature and time sensitive valves and switches.
ii) Hoses, belts, connectors, and assemblies.
3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353
Download from Www.Somanuals.com. All Manuals Search And Download.
|