Hampton Direct Indoor Fireplace H15 LP1 User Manual

Owners &  
H15 Direct Vent Gas Fireplace  
Installation Manual  
MODELS:  
H15-NG1 Natural Gas  
H15-LP1 Propane  
WARNING:  
If the information in these instructions are not  
FOR YOUR SAFETY  
This appliance may only be  
installed in an aftermarket  
permanently located, manu-  
factured (USAonly) or mobile  
followed exactly, a fire or explosion may result What to do if you smell gas:  
causing property damage, personal injury or loss  
of life.  
Do not try to light any appliance  
Do not touch any electrical switch: home,wherenotprohibitedby  
do not use any phone in your  
building.  
local codes.  
FOR YOUR SAFETY  
Do not store or use gasoline or other flammable  
vapours and liquids in the vicinity of this or any  
other appliance.  
Immediately call your gas supplier This appliance is only for use  
from a neighbour's phone. Follow with the type of gas indicated  
the gas supplier's instructions.  
on the rating plate. This ap-  
If you cannot reach your gas sup- pliance is not convertible for  
Installation and service must be performed by  
a qualified installer, service agency or the gas  
supplier.  
plier, call the fire department.  
use with other gases, unless  
a certified kit is used.  
Tested by:  
Installer: Please complete the details on the back cover  
and leave this manual with the homeowner.  
Homeowner: Please keep these instructions for future reference.  
918-516a  
12/17/07  
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Optional Wall Thermostat ...........................................34  
Optional Remote Control ............................................34  
Final Check .................................................................34  
Wiring Diagrams..........................................................35  
Operating Instructions .................................................37  
Lighting Procedure ......................................................37  
Shutdown Procedure...................................................37  
First Fire ......................................................................37  
SAFETY LABEL  
Safety Label ..................................................................4  
REQUIREMENTS  
MA Code - CO Detector ................................................5  
INSTALLATION  
OPERATING INSTRUCTIONS  
Important Message ......................................................6  
Specifications ................................................................6  
Mobile / Manufactured Homes After First Sale..............6  
Before You Start ............................................................6  
General Safety Information ...........................................7  
Installation Checklist......................................................7  
Clearances to Combustibles .........................................7  
Locating Your Gas Stove...............................................8  
Manufactured Mobile Home Additional Requirements ..8  
Combustion and Ventilation Air .....................................8  
Optional Fan Installation................................................8  
Venting Introduction.....................................................10  
Installation Precautions ...............................................10  
Safety Precautions for the Installer .............................10  
Vent Restrictor Position...............................................10  
Rotating Elbow ............................................................10  
Exterior Vent Terminal Locations.................................11  
4” x 6-5/8” Rigid Pipe Cross Reference Chart.............12  
Rigid Pipe Venting Systems ........................................14  
Venting Arrangements.................................................17  
Vertical Termination with Co-linear Flex System .........18  
DV Stove Horizontal Vent Kit.......................................19  
Residential and Manufactured  
Adjusting Flame Height ...............................................37  
Automatic Convection Fan Operation .........................37  
Copy of the Lighting Plate Instructions .......................38  
MAINTENANCE  
Normal Operating Sounds of Gas Appliances.............39  
Maintenance Instructions ............................................39  
Pilot Adjustment...........................................................39  
Fan Maintenance.........................................................40  
General Vent Maintenance..........................................40  
Log Replacement ........................................................40  
Glass Replacement.....................................................40  
Removing Valve...........................................................41  
Installing Valve Assembly ............................................41  
PARTS LIST  
Main Assembly ............................................................42  
Burner & Log Assembly...............................................43  
WARRANTY  
Homes / Mobile Homes ..............................................21  
Minimum Horizontal Termination Installations .............21  
Dura-Vent Termination Kit............................................22  
Horizontal Terminations...............................................23  
Vertical Terminations ...................................................24  
Converting Class-A Metal Chimney  
Warranty......................................................................47  
or Masonry Chimney to Direct Vent System...............26  
Cathedral Ceilings.......................................................27  
High Elevation .............................................................27  
Gas Connection...........................................................27  
Aeration Adjustment ....................................................28  
Gas Pipe Pressure Testing..........................................28  
Conversion Kit# 381-969 from NG to LP.....................29  
Log Set Installation......................................................32  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY LABEL  
NOTE: Hampton® units are constantly being  
improved. Check the label on the unit and if  
there is a difference, the label on the unit is  
the correct one.  
This is a copy of the label that accompanies  
each Direct Vent Freestanding Gas Stove.  
We have printed a copy of the contents here  
for your review.  
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.  
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.  
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.  
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back  
up in the same room where the gas appliance is installed.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
REQUIREMENTS  
MA Code - CO Detector  
(for the State of Massachusetts only)  
5.08: Modifications to NFPA-54, Chapter 10  
(2) Revise 10.8.3 by adding the following additional requirements:  
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for  
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than  
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall  
be satisfied:  
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled  
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is  
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery  
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure  
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of  
qualified licensed professionals for the installation of hard wired carbon monoxide detectors  
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon  
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.  
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of  
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon  
monoxide detector with an alarm shall be installed.  
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions  
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight  
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The  
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL  
OBSTRUCTIONS".  
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation  
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR  
5.08(2)(a)1 through 4.  
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by  
the Board; and  
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or  
structure used in whole or in part for residential purposes.  
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product  
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the  
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:  
1. Detailed instructions for the installation of the venting system design or the venting system components; and  
2. A complete parts list for the venting system design or venting system.  
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a  
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies  
"special venting systems", the following requirements shall be satisfied by the manufacturer:  
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and  
detailed installation instructions.  
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,  
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of  
the installation.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
This appliance installation must comply with the  
manufacturer'sinstallationinstructionsandlocal  
codes, if any. In the absence of local codes fol-  
low the current National Fuel Gas Code, ANSI  
Z223.1 and the current National Electrical Code  
ANSI/NFPA 70 in the U.S.A., and the current  
CAN/CGA B149 Gas Installation Code and the  
current Canadian Electrical Code CSA C22.1  
in Canada.  
IMPORTANT MESSAGE  
SAVE THESE  
WARNING:FAILURETOINSTALL  
THIS APPLIANCE CORRECTLY  
WILL VOID YOUR WARRANTY  
AND MAY CAUSE A SERIOUS  
HOUSE FIRE.  
INSTRUCTIONS  
The Direct Vent Freestanding Gas Stove must  
be installed in accordance with these instruc-  
tions. Carefully read all the instructions in this  
manual first. Consult the building authority  
having jurisdiction to determine the need for a  
permit prior to starting the installation.  
CHILDRENANDADULTSSHOULD  
BE ALERTED TO THE HAZARDS  
OF HIGH SURFACE TEMPERA-  
TURES, ESPECIALLY THE FIRE-  
PLACE GLASS, AND SHOULD  
STAY AWAY TO AVOID BURNS  
OR CLOTHING IGNITION.  
ThisHampton® Mobile/ManufacturedHome  
Listed appliance comes factory equipped  
with a means to secure the unit.  
Note: Failure to follow the instructions  
could cause a malfunction of the  
heater which could result in death,  
serious bodily injury, and/or prop-  
erty damage. Failure to follow these  
instructions may also void your fire  
insurance and/or warranty.  
This Hampton® Mobile/Manufactured  
Home listed appliance comes equipped  
with a dedicated #8 ground lug to which  
an 18 gauge copper wire from the steel  
chassis ground must be attached.  
YOUNG CHILDREN SHOULD  
BE CAREFULLY SUPERVISED  
WHEN THEY ARE IN THE SAME  
ROOM AS THE APPLIANCE.  
Note: These instructions take precedence  
over Simpson Dura-Vent instruc-  
tions.  
Thisappliancemayonlybeinstalledin  
an aftermarket permanently located,  
manufactured (USA only) or mobile  
home, where not prohibited by local  
codes.  
CLOTHING OR OTHER FLAM-  
MABLEMATERIALSHOULDNOT  
BE PLACED ON OR NEAR THE  
APPLIANCE.  
SPECIFICATIONS  
This appliance is only for use with  
thetypeofgasindicatedontherating  
plate. This appliance is not convert-  
ible for use with other gases, unless  
a certified kit is used.  
Fuels:  
H15-NG1 is approved for use with  
natural gas.  
1) Provide adequate clearances for servicing,  
properoperationandaroundtheairopenings  
into the combustion chamber.  
H15-LP1 is approved for use with liq-  
uefied petroleum gases (propane).  
2) The appliance must be installed on a flat,  
solid, continuous surface (e.g. wood, metal,  
concrete). This may be the floor, or it can be  
raised up on a platform to enhance its visual  
impact. The appliance may be installed on  
carpeting, tile, wood flooring or other com-  
bustible material, because the appliance's  
base extends the full width and depth of the  
appliance. The Direct Vent Freestanding  
Gas Stove can be installed in a wide variety  
of ways and will fit nearly any room layout.  
It may be installed in a recessed position,  
framed out into the room, or across a cor-  
ner.  
Electrical: 120V A.C. system.  
BEFORE YOU START  
Optional Circulation Fan:  
Variable speed, 125/75.  
Safe installation and operation of this appli-  
ance requires common sense, however, we  
are required by the Canadian Safety Standards  
and ANSI Standards to make you aware of the  
following:  
Log Sets: Ceramic fibre, 4 per set.  
Vent System: Coaxial (6-5/8" outer / 4" inner  
liner) rigid flue and termination cap.  
INSTALLATION AND REPAIRS  
SHOULD BE DONE BY A QUALI-  
FIEDSERVICEPERSON.THISAP-  
PLIANCESHOULDBEINSTALLED,  
REPAIRED,INSPECTEDBEFORE  
USE AND AT LEAST ANNUALLY  
BY A QUALIFIED SERVICE PER-  
SON. MORE FREQUENT CLEAN-  
ING MAY BE REQUIRED DUE TO  
EXCESSIVELINTFROMCARPET-  
ING,ETC. ITISIMPERATIVETHAT  
THE CONTROL COMPARTMENT,  
BURNERS AND CIRCULATING  
AIR PASSAGEWAYS OF THE AP-  
PLIANCE BE KEPT CLEAN.  
MOBILE /  
MANUFACTURED  
HOMES AFTER  
FIRST SALE  
3) The Direct Vent Freestanding Gas Stove is  
approvedforalcoveinstallations,whichmeet  
the clearances listed in the "Clearance to  
Combustibles"section. Thisunitisapproved  
for manufactured home installations, see  
the "Manufactured Mobile HomeAdditional  
Requirements" and "Rigid Pipe Venting  
Systems" sections for the required vent ar-  
rangements.Ifinstalledintoamanufactured  
home the unit must be bolted down to the  
floor.  
This Hampton® product has been tested and  
listed by ITS Testing Services as a Direct Vent  
Room Heater to the following standards:  
CGA-2.17-M91, and ANSI Z21.88B-2003/CSA  
2.33B-2003.  
This Direct Vent System Appliance must be  
installed in accordance with the manufacturer's  
installation instructions and the Manufactured  
Home Construction and Safety Standard, Title  
24 CFR, Part 3280, or the current Standard of  
Fire Safety Criteria for Manufactured Home In-  
stallations,Sites,andCommunitiesANSI/NFPA  
501A, and with CAN/CSA Z240-MH Mobile  
Home Standard in Canada.  
4) This appliance is Listed for bedroom instal-  
lations when used with a Listed Millivolt  
Thermostat. Some areas may have further  
requirements, check local codes before  
installation.  
DUE TO HIGH TEMPERATURES,  
THE APPLIANCE SHOULD BE  
LOCATED OUT OF TRAFFIC AND  
AWAY FROM FURNITURE AND  
DRAPERIES.  
5) This appliance is Listed for Alcove installa-  
tions, maintain minimumAlcove clearances  
as follows, minimum width of 32-1/2"  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
INSTALLATION  
(825mm),amaximumdepthof36"(914mm),  
and minimum height of 24" (610mm) from  
top of unit to ceiling.  
INSTALLATION  
CHECKLIST  
CLEARANCES TO  
COMBUSTIBLES  
6) We recommend that you plan your instal-  
lation on paper using exact measurements  
for clearances and floor protection before  
actually installing this appliance. Have a  
qualifiedbuildinginspectorreviewyourplans  
before installation.  
1) Locate your gas appliance. Refer to the  
The clearances listed are MINIMUM distances.  
Measure the clearance to both the appliance  
and the chimney connector. The farthest  
distance is correct if the two clearances do  
not coincide.  
following sections:  
a. Locating Your Gas Stove  
b. Clearances to Combustibles  
c. "Venting Introduction" to "Exterior Vent  
Terminal Locations" sections.  
For example, if the appliance is set as indicated  
in one of the figures but the connector is too  
close,movethestoveuntilthecorrectclearance  
to the connector is obtained.  
2) Install Optional Fan. Refer to the "Optional  
GENERAL SAFETY  
INFORMATION  
Fan Installation" section.  
3) Setventrestrictor.Refertothe"VentRestric-  
This appliance may be installed only with the  
clearances as shown in the situations pictured.  
Do not combine clearances from one type of  
installation with another in order to achieve  
closer clearances.  
tor Position" section.  
1) Theapplianceinstallationmustconformwith  
local Canadian Electrical Code.  
4) Install venting: Check all venting require-  
ments. See"VentingIntroduction"to "Dura-  
Vent Vertical Termination" sections.  
2) The appliance when installed, must be  
electrically grounded in accordance with  
local codes, or in the absence of local codes  
with the current National Electrical Code,  
ANSI/NFPA 70 or CSA C22.1 Canadian  
Electrical Code.  
This unit can be installed on a solid combustible  
surface like a wood floor. This unit can also be  
installed directly on carpeting or vinyl.  
5) Make gas connections. Refer to the "Gas  
Connection" section.  
Test the pilot. Must be as per diagram in the  
"Pilot Adjustment" section.  
Use the minimum clearances shown in the  
diagrams below:  
3) The applianceshouldbeinspectedforship-  
ping damage before use and serviced an-  
nually by a professional service person.  
Morefrequentcleaningmayberequireddue  
to excessive lint from carpeting, bedding  
material, etc. It is imperative that control  
compartments, and circulating air passage-  
waysoftheappliancebekeptcleanandfree  
from excessive lint from carpeting.  
If converting to Propane, make changes  
prior as instructed in the "Conversion from  
Natural Gas to Propane" section.  
H15-NG1 & H15-LP1 Clearances  
A Left Side Wall to Unit*  
*BBack Wall to Unit  
6" / 150 mm  
0" / 0 mm  
6) Test Gas Pressure. Refer to the "Gas Pipe  
C Vertical Vent Pipe to Back Wall  
2" / 50 mm  
2" /50 mm  
Pressure Testing" section.  
7) Installstandardandoptionalfeatures. Refer  
E Unit Corner to Wall  
to the following sections where applicable:  
4) See general construction and assembly  
instructions. The appliance and vent should  
be enclosed when installed in or passing  
through a living area, where children may  
come in contact with it.  
Unit Top to Alcove Ceiling 24" / 610 mm  
a. Log Set Installation  
b. Wall Thermostat  
c. Remote Control  
Minimum ceiling height is 24" /610 mm from  
top of unit.  
8) Final check. Refer to the "Final Check" sec-  
5) This appliance must be connected to the  
*IMPORTANT  
tion.  
specified vent and termination cap to the  
It is recommended that unit is moved away from  
thewall, ifinstallingthebloweroption, sothefan  
can be easily installed and/or serviced.  
outside of the building envelope.  
Never  
Before leaving this unit with the customer, the  
installer must ensure that the appliance is fir-  
ing correctly and operation fully explained  
to customer.  
vent to another room or inside a building.  
Make sure that the vent is fitted as per the  
instructions starting in the "Exterior Vent  
Terminal Locations" section.  
This includes:  
6) Inspect the venting system annually for  
blockage and any signs of deterioration.  
1) Clockingtheappliancetoensurethecorrect  
firing rate (rate noted on label) after burning  
appliance for 15 minutes.  
7) Venting terminals shall not be recessed into  
a wall or siding.  
2) Ifrequired,adjustingtheprimaryairtoensure  
that the flame does not carbon. First allow  
the unit to burn for 15-20 min. to stabilize.  
8) Anysafetyglassremovedforservicingmust  
be replaced prior to operating the appli-  
ance.  
9) To prevent injury, do not allow anyone who  
is unfamiliar with the operation to use the  
fireplace.  
CAUTION:Any alteration to the product that  
causes sooting or carboning that results  
in damage is not the responsibility of the  
manufacturer.  
Emissions from burning wood or gas could  
contain chemicals known to the State of Cali-  
fornia to cause cancer, birth defects or other  
reproductive harm.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
INSTALLATION  
4) Removethenylonholeplugfromthecontrol  
OPTIONAL FAN  
INSTALLATION  
LOCATING YOUR  
GAS STOVE  
When selecting a location for your stove, ensure  
that the clearances listed above are met as well  
as ensuring that there is adequate accessibility  
for servicing and proper operation.  
panel.  
5) Install the fan speed controller onto the  
control panel and secure with nut and  
washer. Connect the red and black wires  
from the wire harness to speed controller.  
NOTE: Speed control wires must be in  
the down position when control panel is  
in place.  
Fan Kit Contains:  
Qty. Description  
1
1
1
1
Fan Assembly c/w green wire attached  
Thermodisc  
Fan Speed Control  
Grommet  
6) Push black knob onto speed control.  
1) Remove the rear access panel on the back  
ofthestovebyremovingthe2screwsunder  
the rear panel, then lift rear panel off of 2  
bolts at the top. Take care not to cut wires  
when lowering the panel.  
Fan Speed  
Controller  
* 12' max. only if vertical height is achieved.  
A) Cross Corner  
B) Room Divider  
C) Island  
D) Flat on Wall  
E) Flat on Wall Corner  
F) Flush with Wall/Alcove  
screw  
screw  
For Vent Termination requirements, see the  
"Exterior Vent Terminal Locations" section.  
MANUFACTURED  
MOBILE HOME  
ADDITIONAL  
7) Re-attach control panel with 3 screws,  
reversing step 3.  
8) Slide Thermodisc into the bracket on the left  
REQUIREMENTS  
side of the rear firebox.  
bolt  
1) Ensure that structural members are not cut  
Lift Rear Panel off of the 2 top bolts.  
or weakened during installation.  
2) Disconnect the red and grey wires.  
2) Ensure proper grounding using the #8  
ground lug provided.  
3) Appliance must be anchored to the floor  
with the supplied anchoring methods.  
COMBUSTION AND  
VENTILATION AIR  
Thecombustionairfromthisapplianceisdrawn  
from outside the building through the outer flue.  
Extraprovisionforcombustionairinsidethe  
room is not required.  
3) Remove the Top Control Panel Assembly  
by removing the three screws.  
Thermodisc  
Thermodisc  
Bracket  
Top Control Panel Assembly  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
INSTALLATION  
12) Slide fan into place and secure with the two 14) Connect fan ground wire to lug nut at base  
9) Remove 2 screws from unit.  
screws removed in step 9.  
of unit.  
Lug Nut  
10) Place grommet in rear plate through the  
bottom of the opening as shown below.  
13) Connectlongblack&redwirestothermodisc  
15) Before re-attaching the rear access panel,  
the valve wires and the fan wires need to  
be connected.  
and secure wires.  
Re-connect the red and grey valve wires  
removed in step 2.  
Rear Plate  
Grommet  
Connect the black and white fan wires as  
per the wiring diagram below.  
11) Place the blower close to the base of the unit  
and feed the wires through the grommet in  
the rear plate.  
16) Slide the RearAccess Panel back into posi-  
tion and secure with 2 screws.  
Wires  
WARNING: Electrical Grounding Instructions  
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged  
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
VENTING  
INTRODUCTION  
INSTALLATION  
PRECAUTIONS  
SAFETY PRECAUTIONS  
FOR THE INSTALLER  
TheHorizontalTerminationKitandtheSimpson  
Dura-Vent Direct Vent System Model DV-GS  
ventingsystems, incombinationwiththe Direct  
Vent Freestanding Gas Stoves, H15-NG1, and  
H15-LP1, have been tested and listed as direct  
vent heater systems by Warnock Hersey.  
Theseventingsystemsareengineeredproducts  
that have been designed and tested for use  
with the H15-NG1, and H15-LP1. The warranty  
will be voided and serious fire, health or other  
safety hazards may result from any of the fol-  
lowing actions:  
1) Wear gloves and safety glasses for protec-  
tion.  
2) Exercise extreme caution when using lad-  
ders or on roof tops.  
3) Be aware of electrical wiring locations in  
Theseunitsusethe"balanced flue" technology  
Co-Axial system.The inner liner vents products  
ofcombustiontotheoutsidewhiletheouterpipe  
draws outside combustion air into the combus-  
tion chamber thereby eliminating the need to  
use heated room air for combustion and losing  
warm room air up the chimney.  
1) Installation of any damaged Rigid Pipe  
walls and ceilings.  
component.  
2) UnauthorizedmodificationofanyRigidPipe  
VENT RESTRICTOR  
POSITION  
To set the Vent restriction as indicated in the  
Venting Arrangement diagrams in the "Rigid  
Pipe Venting System" section, simply loosen  
the screws and push the vent restrictor plate to  
the correct position. Tighten the screws. This  
will be located inside the firebox.  
System.  
3) InstallationotherthanasinstructedbySimp-  
son Dura-Vent and FPI Fireplace Products  
International Ltd.  
Note: These flue pipes must not be  
connected to any other appliance.  
Warning: Alwaysmaintainrequired  
clearances (air spaces) to nearby  
combustibles to prevent a fire  
hazard. Do not fill air spaces with  
insulation.  
The gas appliance and vent system must be  
vented directly to the outside of the building,  
and never be attached to a chimney serving a  
separate solid fuel or gas burning appliance.  
Eachdirectventgasappliancemustuseit'sown  
separate vent system. Common vent systems  
are prohibited.  
Be sure to check the vent termination clearance  
requirements from decks, windows, soffits,  
gas regulators, air supply inlets and public  
walkways as specified in the "Exterior Vent  
Terminal Locations" section and in your local  
building codes.  
IMPORTANT  
Read all instructions carefully before starting  
the installation. Failure to follow these instruc-  
tions may create a fire or other safety hazard,  
and will void the warranty. Be sure to check the  
venting and clearance to combustible require-  
ments. Consultyourlocalbuildingcodesbefore  
beginning installation.  
The gas appliance and vent system must be  
venteddirectlytotheoutsideofthebuilding,  
and never be attached to a chimney serving  
a separate solid fuel or gas-burning appli-  
ance. Each direct vent gas appliance must use  
it's own separate vent system. Common vent  
systems are prohibited.  
The location of the termination cap must con-  
form to the requirements in the "Exterior Vent  
Terminal Locations" section.  
ROTATING ELBOW  
3) Rotate the elbow 180o  
1) Remove top casting.  
2) Remove all 4 screws that secure  
the elbow to the unit using a 1/4"  
magnetic nut driver.  
4) Secure the elbow by securing  
it with the 4 screws.  
Remove all 4 screws  
and washers  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
INSTALLATION  
EXTERIOR VENT TERMINAL LOCATIONS  
A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)  
B= Clearance to window or door that may be opened *(12"/30cm)  
C= Clearance to permanently closed window *(min. 12"/30cm)  
D= Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal  
(min. 22"/55cm) check with local code.  
E= Clearance to unventilated soffit (min. 12"/30cm)  
F= Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura-Vent Termination Cap (min.12"/30cm), with Riser Vent  
(min. 6"/15cm)  
G= Clearance to inside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura-Vent Termination Cap (min.12"/30cm), with Riser Vent  
(min. 6"/15cm)  
H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from the centerline of the regulator.  
J= Clearance to service regulator vent outlet *(min. 36"/90cm)  
K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance *(12"/30cm)  
L= Clearance to a mechanical air supply inlet *(min. 72"/1.8m)  
M= **Clearance above paved sidewalk or a paved driveway located on public property *(min. 84"/2.1m)  
N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)***  
Note: * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.  
**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both  
dwellings.  
***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART  
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.  
Simpson  
American Metal  
Simpson  
Metal-Fab®  
Security  
Selkirk  
Direct Vent GS®  
Products®  
Description  
Direct Vent Pro®  
Sure Seal  
Secure Vent®  
Direct-Temp™  
Amerivent Direct  
Discontinued  
46DVA-06  
46DVA-06B  
N/A  
908  
908B  
N/A  
N/A  
907  
907B  
906  
906B  
N/A  
N/A  
904  
904B  
903  
903B  
902  
902B  
N/A  
N/A  
4DT-6  
4DT-6B  
N/A  
N/A  
4DT-9  
4DT-9B  
4DT-12  
4DT-12B  
4DT-18  
4DT-18B  
4DT-24  
4DT-24B  
4DT-36  
4DT-36B  
4DT-48  
4DT-48B  
N/A  
N/A  
N/A  
4D7  
4D7B  
N/A  
4D6  
4D6B  
N/A  
N/A  
N/A  
SV4L6  
SV4LB6  
N/A  
N/A  
N/A  
6” Pipe Length, Galvanized  
6” Pipe Length, Black  
7” Pipe Length, Galvanized  
7” Pipe Length, Black  
9” Pipe Length, Galvanized  
9” Pipe Length, Black  
12” Pipe Length, Galvanized  
12” Pipe Length, Black  
18” Pipe Length, Galvanized  
18” Pipe Length, Black  
24” Pipe Length, Galvanized  
24” Pipe Length, Black  
36” Pipe Length, Galvanized  
36” Pipe Length, Black  
48” Pipe Length, Galvanized  
48” Pipe Length, Black  
N/A  
46DVA-09  
46DVA-09B  
46DVA-12  
46DVA-12B  
46DVA-18  
46DVA-18B  
46DVA-24  
46DVA-24B  
46DVA-36  
46DVA-36B  
46DVA-48  
46DVA-48B  
46DVA-60  
46DVA-60B  
N/A  
N/A  
N/A  
4D12  
4D12B  
N/A  
4D12  
4D12B  
4D18  
4D18B  
4D24  
4D24B  
4D36  
4D36B  
4D48  
4D48B  
N/A  
SV4L12  
SV4LB12  
SV4LA  
SV4LA  
SV4L24  
SV4LB24  
SV4L36  
SV4LB36  
SV4L48  
SV4LB48  
N/A  
N/A  
4D2  
4D2B  
4D3  
4D3B  
4D4  
4D4B  
N/A  
60” Pipe Length, Galvanized  
60” Pipe Length, Black  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
911B  
N/A  
N/A  
4DT-AJ  
4DT-AJB  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
4D7A  
4D7AB  
N/A  
4DAL  
4DALB  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
SV4LBA24  
N/A  
N/A  
N/A  
Adjustable Length 3”-10”, Galvanized  
Adjustable Length 3”-10”, Black  
Adjustable Length 11”-14”, Galvanized  
Adjustable Length 11”-14”, Black  
Adjustable Length 17”-24”, Galvanized  
Adjustable Length 17”-24”, Black  
Adjustable Length 7”, Galvanized  
Adjustable Length 7”, Black  
Extension Pipe 8-1/2”, Galvanized  
Extension Pipe 8-1/2”, Black  
Adjustable Length 12”, Galvanized  
Adjustable Length 12”, Black  
Disc - See 46DV-08A  
Disc - See 46DV-08AB  
Disc - See 46DV-16A  
Disc - See 46DV-16AB  
N/A  
917 - N/A from FPI N/A  
917B  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
46DVA-08A  
46DVA-08AB  
N/A  
N/A  
46DVA-16A  
46DVA-16AB  
N/A  
N/A  
4D12A  
4D12AB  
N/A  
SV4LA12  
SV4LBA12  
N/A  
Extension Pipe 16”, Galvanized  
Extension Pipe 16”, Black  
N/A  
N/A  
N/A  
46DVA-E45  
46DVA-E45B  
Disc - See 46DVA-E45  
Disc - See 46DVA-  
E45B  
945  
945B  
945G  
4DT-EL45  
4DT-EL45B  
N/A  
4D45L  
4D45LB  
N/A  
N/A  
N/A  
4D45L  
N/A  
N/A  
SV4E45  
45º Elbow, Galvanized  
45º Elbow, Black  
45º Elbow, Swivel, Galvanized  
945BG  
N/A  
N/A  
4D45LB  
SV4EB45  
45º Elbow, Swivel, Black  
46DVA-E90  
46DVA-E90B  
Disc - See 46DVA-E90  
Disc - See 46DVA-  
E90B  
990  
990B  
990G  
4DT-EL90S  
4DT-EL90SB  
N/A  
4D90LS  
4D90LBS  
N/A  
N/A  
N/A  
4D90L  
N/A  
SV4EBR90-1  
SV4E90-1  
90º Elbow, Galvanized  
90º Elbow, Black  
90º Elbow, Swivel, Galvanized  
990BG  
N/A  
N/A  
4D90LB  
SV4EB90-1  
90º Elbow, Swivel, Black  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
4D90A  
4DDA  
N/A  
N/A  
90º Starter Elbow, Swivel, Galvanized*  
Adaptor*  
N/A  
949 - N/A from FPI 4DT-CS  
4DFSP  
4DRSB  
4DWS  
N/A  
4DWT  
N/A  
4DFSP  
4DFPB  
N/A  
4DSP  
4DRS  
4DWS  
N/A  
4DWT  
N/A  
4DFS  
4DCP  
N/A  
SV4SD  
SV4CSB  
SV4BM  
SV4SU  
SV4RSM  
SV4PF  
SV4BF  
SV4LA  
N/A  
Ceiling Support  
Cathedral Support Box  
Wall Support/Band  
Offset Support  
Wall Thimble, Black  
Wall Thimble Support Box/Ceiling Support  
Firestop Spacer  
Trim Plate, Black  
Masonry Chimney Flashing  
Brass Trim for Wall Thimble/Ceiling Support  
46DVA-CS  
46DVA-WS  
46DVA-ES - N/A from FPI  
46DVA-WT  
46DVA-DC  
46DVA-FS  
N/A  
941  
988  
4DT-CSS  
4DT-WS/B  
989 - N/A from FPI 4DT-OS  
942  
N/A  
963  
N/A  
N/A  
3951  
4DT-WT  
N/A  
4DT-FS  
4DT-TP  
N/A  
N/A  
DISC.  
N/A  
N/A  
N/A  
N/A  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
INSTALLATION  
4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.)  
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.  
Simpson  
American Metal  
Simpson  
Metal-Fab®  
Security  
Selkirk  
Direct Vent GS®  
Products®  
Description  
Direct Vent Pro®  
Sure Seal  
Secure Vent®  
Direct-Temp™  
Amerivent Direct  
Discontinued  
46DVA-IS - N/A from FPI  
N/A  
N/A  
N/A  
N/A  
N/A  
4DAIS12  
4DAIS36  
N/A  
N/A  
SV4RSA  
N/A  
Attic Insulation Shield 12”  
Attic Insulation Shield - Cold Climates 36”  
DISC.  
46DVA-KHA  
(Changed Components)  
970  
971  
978  
4DT-HKA  
4DT-HKB  
4DT-VKC  
4DHTK2  
4DHTK1  
4DVTK  
4DHTKA  
4DHTKB  
4DVTK  
SV - SHK  
SV - HK  
SV - FK  
Basic Horizontal Termination Kit (A)  
Horizontal Termination Kit (B)  
Vertical Termination Kit  
DISC.  
46DVA-VCH  
46DVA-HC  
Disc - See 46DVA-HC  
46DVA-VC  
991  
985  
984  
980  
953  
N/A  
N/A  
4DT-HHC  
4DT-HVC  
4DT-SC  
N/A  
N/A  
4DHC  
4DVC  
4DSC  
N/A  
N/A  
4DHT  
4DVT  
4DSC  
N/A  
N/A  
SV4CHC-1  
SV4CGV-1  
SV4FC  
High Wind Vertical Cap  
High Wind Horizontal Cap  
Horizontal Square Termination Cap  
Vertical Termination Cap  
Storm Collar  
46DVA-SC  
46DVA-F6  
46DVA-F12  
943  
943S  
4DT-AF6  
4DT-AF12  
4DF  
4DF12  
4DF  
4DF-12  
SV4FA  
SV4FB  
Adjustable Flashing, 0/12-6/12  
Adjustable Flashing, 6/12-12/12  
46DVA-VSS  
N/A  
950  
N/A  
4DT-VS  
4DT-VSP  
N/A  
N/A  
4DVS  
N/A  
SV4VS  
SV4VS  
Vinyl Siding Standoff  
Vinyl Siding Shield Plate  
46DVA-SNK14  
N/A  
982  
981  
4DT-ST14  
4DT-ST36  
4D12S  
4D36S  
4DST14  
4DST36  
SV4STC14  
SV4STC36  
Snorkel Termination 14”  
Snorkel Termination 36”  
46DVA-RD  
929  
930  
931  
932  
933  
934  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Restrictor Disk  
46DVA-VCE  
46DVA-KCA  
46DVA-KCB  
46DVA-KCC  
46DVA-KMC  
Extended Vertical Termination Cap  
Chimney Conversion Kit A  
Chimney Conversion Kit B  
Chimney Conversion Kit C  
Chimney Conversion Kit Masonry  
Mansonry Chimney Conversion Kit  
46DVA-KCT  
935  
N/A  
N/A  
N/A  
N/A  
(includes: Cap Adapter 18”x18” Flashing)  
46DVA-WFS  
46DVA-ADF  
947  
923F  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Wall Firestop  
Colinear Flex Connectors  
FPI  
946-506/P  
510-994  
Vent Guard (Optional) for AstropCap  
Rigid Pipe Adapter (Must use with all Rigid Piping)  
Riser Vent Terminal  
946-205  
Vinyl Siding Shield for Riser Vent Terminal  
Vent Guard (Optional) for Riser Vent Terminal  
AstroCap Horizontal Cap  
946-208/P  
946-523/P  
946-206  
640-530/P  
Vinyl Siding Standoff for AstroCap  
*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (4DDA) or 90º Starter Elbow (4D90A)  
must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).  
Offset Pipe Selection:  
Use this table to determine offset pipe lengths.  
For specific instructions or details on particular  
4” x 6-5/8” Venting  
venting components please visit the following  
websites:  
Pipe Length  
Run (X)  
Rise (Y)  
Simpson Direct Vent Pro: www.duravent.com  
Selkirk Direct-Temp: www.selkirkcorp.com  
0”(0mm)  
4-7/8”(124mm)  
8”(203mm)  
13-3/8”(340mm)  
16-1/2”(419mm)  
18-5/8”(473mm)  
6”(152mm)  
9”(229mm)  
L
American Metal Products Amerivent Direct:  
10-1/8”(257mm)  
Y
12”(305mm)  
24”(610mm)  
36”(914mm)  
48”(1219mm)  
12-1/4”(311mm)  
20-5/8”(524mm)  
29”(737mm)  
20-3/4”(527mm)  
29-1/8”(740mm)  
37-1/2”(953mm)  
45-15/16”(1167mm)  
Metal-Fab Sure Seal: www.mtlfab.com  
Security Secure Vent: www.securitychimneys.com  
37-7/16”(951mm)  
X
NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards  
the termination. Never allow the vent to run downward. This could cause high temperatures and  
may present a possible fire hazard.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
RIGID PIPE VENTING SYSTEMS  
Horizontal or Vertical Terminations  
Alternate  
Horizontal  
Termination  
Caps  
Vertical  
Termination  
Cap  
Storm Collar  
Vinyl Siding  
Standoff (Optional)  
Flashing  
Horizontal  
Termination  
Cap  
Ceiling Firestop  
Wall Thimble  
Pipe Length  
Adj.Pipe Length  
11" - 14-5/8"  
90o Elbow  
WARNING:  
Do not combine venting components from  
different venting systems.  
24" Pipe  
Length  
TM  
However use of the the AstroCap and FPI  
Riser is acceptable with all systems.  
ThisproducthasbeenevaluatedbyIntertekfor  
using a Rigid Pipe Adaptor in conjunction with  
DuraventDirect-VentGS,SelkirkDirect-Temp,  
Ameri Vent Direct venting and Security Secure  
Vent systems. Use of these systems with the  
Rigid Pipe adaptor is deemed acceptable  
and does not affect the Intertek WHI listing of  
components.  
When using Rigid Vent other than  
Simpson Dura-Vent, 3 screws must be  
used to secure rigid pipe to adaptor.  
The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent GS,  
American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace  
Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
INSTALLATION  
Horizontal Venting with Two (2) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option  
A)  
V
H + H1  
3' Max.  
With these options, maxi-  
mum total pipe length is 30  
feet with minimum of 6 feet  
total vertical and maximum  
8 feet total horizontal.  
Please note minimum 1  
foot between 90o elbows  
is required.  
1' Min.  
2' Min.  
3' Min.  
4' Min.  
5' Min.  
6' Min.  
B)  
C)  
D)  
E)  
4' Max.  
5' Max.  
6' Max.  
7' Max.  
8' Max.  
F)  
H1  
Lengths do not include elbow indicated  
V
Vent restrictor position A (fully open), refer to the "Vent  
Restrictor Postion" section.  
Horizontal Venting with Two (2) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option  
A)  
H
V
H + H1 With these options, max.  
total pipe length is 30 feet  
1' Max. 1' Min. 3' Max.  
2' Max. 2' Min. 5' Max.  
3' Max. 4' Min. 6' Max.  
4' Max. 6' Min. 7' Max.  
5' Max. 8' Min. 8' Max.  
with min. of 8 feet total  
vertical and max. 8 feet  
total horizontal.  
Please note min. 1 foot  
between 90o elbows is  
required.  
B)  
C)  
D)  
E)  
Lengths do not include elbow indicated  
Vent restrictor position A (fully open), refer to the "Vent  
Restrictor Postion" section.  
V
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Vertical Venting with Two (2) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option V  
H
V + V1  
With these options, max. total  
pipe length is 30 feet with min.  
of6feettotalverticalandmax.  
8 feet total horizontal.  
Please note min. 1 foot  
between 90o elbows is re-  
quired.  
A)  
B)  
C)  
D)  
E)  
1' Min. 4' Max. 2' Min.  
2' Min. 5' Max. 3' Min.  
3' Min. 6' Max. 4' Min.  
4' Min. 7' Max. 5' Min.  
5' Min. 8' Max. 6' Min.  
V1  
Lengths do not include elbow indicated  
V
H
Vent restrictor position A (fully open), refer to the "Vent  
Restrictor Postion" section.  
Vertical Venting with Two (2) 90o Elbows  
One 90o elbow = Two 45o elbows.  
Option H + H1  
V
Withtheseoptions,max.total  
A)  
B)  
C)  
D)  
E)  
2' Max. 2' Min. pipelengthis30feetwithmin.  
of6feettotalverticalandmax.  
3' Max. 3' Min.  
6 feet total horizontal.  
4' Max. 4' Min.  
5' Max. 5' Min.  
6' Max. 6' Min. required.  
Please note min. 1 foot  
between 90o elbows is  
Lengths do not include elbow indicated  
Vent restrictor position A (fully open), refer to the  
"Vent Restrictor Postion" section.  
V
H
H1  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
INSTALLATION  
VENTING ARRANGEMENTS  
Vertical Terminations Systems for  
Residential Manufactured and Mobile Homes  
Horizontal Terminations for  
All Venting Systems  
The shaded area in the diagram below shows all allowable combinations of straight  
vertical and offset to vertical runs with vertical terminations. Maximum two 45o  
elbows.  
The shaded areas in the diagram below show all  
allowable combinations of vertical runs with hori-  
zontal terminations. Maximum one 90O elbow (two  
45o elbows equal one 90o elbow).  
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to  
combustibles.  
Propane and Natural Gas:  
Residential, Manufactured and Mobile  
Homes Installations  
May be installed in Manufactured (Mobile) Homes after first sale.  
Offset to Vertical Terminations  
May be installed in Manufactured (Mobile)  
Homes after first sale.  
Venting Arrangements - Horizontal Terminations  
The two diagrams show all allowable com-  
binationsofstraighthorizontal termination  
with one 45o elbow off the unit. Restrictor  
position "A".  
12" max. w/AstroCap or Simpson Duravent  
Horizontal Square Termination Cap.  
24" max. w/FPI Riser or Simpson Duravent  
Snorkel Termination Cap.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM  
Masonry chimneys may take various contours which the flexible liner will accommodate. However,  
THE APPLIANCE MUST NOT BE  
CONNECTED TO A CHIMNEY FLUE  
SERVING A SEPARATE SOLID FUEL  
BURNING APPLIANCE.  
keep the flexible liner as straight as possible, avoid unnecessary bending.  
The Air Intake pipe must be attached to the inlet air collar of the termination cap.  
This appliance is designed to be attached to  
two 3" (76mm) co-linear aluminium flex running  
the full length of the chimney. See the Venting  
Arrangements chart below for minimum and  
maximum flue lengths. See chart below for  
minimumdistancesfromroof.Periodicallycheck  
that the vent is unrestricted.  
Alternate Approved Caps  
Required Parts:  
980  
991  
Vertical Termination Cap  
High Wind Cap  
Part #  
Description  
946-529  
Co-linear DV Vertical  
Termination Cap  
3" Flex - 35 ft.  
923GK 3" Co-linear Adapter with flashing  
948-305  
946-563  
Kit  
Co-Axial to Co-Linear Adapter  
which contains the following:  
Co-linear Flex Adapter (270-585)  
Outer Pipe (946-257)  
Inner Pipe Adapter (946-219)  
Venting Arrangements - Vertical Terminations  
with Co-linear Flex System for both  
Residential & Manufactured Homes  
into Masonry Fireplaces  
The shaded area in the diagram shows the allowable vertical  
terminations.  
Straight Vertical Terminations  
Vent Restrictors  
set at fully closed,  
Position "B"  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
DV STOVE HORIZONTAL VENT KIT  
DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed  
to install the H15-1 Direct Vent unit with up & out horizontal and vertical vent dimensions. For installations that  
require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termina-  
tion Kit" and "Dura-Vent Venting Components" sections.  
Qty.  
Description  
1)  
2)  
1
Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,  
Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm)  
inside diameter  
1
Flex Liner, compressed aluminium 2 ply liner, 4" (102mm)  
inside diameter  
spring spacers  
90 deg. Elbow  
3)  
4)  
5)  
6)  
7)  
8)  
9)  
4
1
1
1
1
1
1
Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.  
Thimble Cover  
Wall Thimble (2 pcs.)  
Adapter  
AstroCap Termination Cap  
Note:  
10) 2  
11) 1  
12) 12  
13) 14  
14) 4  
15) 4  
16) 8  
Trim Collars  
a) Liner sections should be con-  
tinuous without any joints or  
seams.  
b) This is an approved system,  
therefore components in this  
systemmustnotbesubstituted  
for any other manufacturer's  
products.  
tube of Mill-Pac, high temperature sealant  
Screws, #8 x 1/2" Self tapping, Stainless Steel  
Screws, #8 x 1/2" Self tapping, Black  
Screws #8 x 1-1/2" Drill Point, Black  
Screws #8 x 1-1/2" Drill Point, Stainless Steel  
Wood screws #8 x 1"  
DV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION  
Review the following sequence of instructions  
which are typical of most installations. The  
sequence may vary depending on wall thick-  
ness. Refer to the "Exterior Vent Terminal  
Locations"and"RigidPipeVentingSystems"  
sections for vent location and clearance  
dimensions, and the "Vent Restrictor Posi-  
tion" for the correct positioning.  
b) Install wall thimbles on both interior  
and exterior wall with 4 wood screws  
(#8 x 1") per thimble.  
c) Attachthe2pieceadjustablepipesec-  
tion to the vent terminal and slide into  
position from the exterior. The larger  
diameter end of the adjustable pipe  
goes to the vent terminal.  
1) Set the unit in its desired location. Check  
to determine if wall studs will be in the way  
of the venting system, adjust location until  
all clearances are met and there are no  
obstructions.  
d) Install the 90o  
elbow onto the adjust-  
able pipe to determine the vertical  
centerline.  
Note:ifthecenterlinecannotbemet,  
the adjustable sections will have to  
be cut.  
Note: A1-1/2"(38mm)clearancearoundthe  
outerpipemustbemaintainedexcept  
that only a 1" (25mm) clearance is  
needed at the termination end.  
e) Cut the 4 ft. section of rigid pipe to  
length.Attachthe 45o elbowtotherigid  
pipe, and ensure that the pipe length  
when cut (with the 45o elbow) will seat  
onto both the starter collar and the 90o  
elbow. Crimpedsectionofrigidpipe  
seats into the 90o elbow. Only cut  
the uncrimped side of pipe.  
IMPORTANT:  
Do not locate termination hood  
where excessive snow or ice  
buildupmayoccur.Besuretocheck  
vent termination area after snow  
falls,andcleartopreventaccidental  
blockage of venting system. When  
using snow blowers, make sure  
snow is not directed towards vent  
termination area.  
2) Assembleatrialttodeterminethevertical  
center-line for the vent termination.  
Dismantle all pipe sections including vent  
terminal.  
a) Cut a 9-1/2" x 9-1/2" (241mm x 241  
mm) square hole on both the interior  
and exterior wall.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
INSTALLATION  
9) Securethe4"dia.exlinertothe4"adapter  
with Mill-Pac and 3 of the #8 x 1/2" screws  
(stainless steel).  
10) SlidethedecorativeThimbleCoveroverthe  
pipe sections and secure with 4 screws (#8  
x 1-1/2" drill point, black) to the wall.  
11) Slide the 90o elbow (crimp end up), the 45o  
elbow and the 4 ft. pipe section (crimp end  
up) over the 4" dia. flex liner.  
12) Install the spring spacers onto the pipe  
sections.  
13) Secure the 4" dia. flex liner with adapter  
onto the stove collar. Put a bead of Mill-Pac  
around the appliance adapter and secure  
with 3 screws (#8 x 1/2, stainless steel).  
14) Attach the 45o elbow onto the starter col-  
lar by sealing with Mill-Pac and/or high  
temperature silicone and securing with 3  
of the #8 x 1/2" (black) screws.  
Note: If installing termination  
on a siding cov-  
15) Attach the pipe section to the 45o elbow by  
sealing with Mill-Pac and/or high tempera-  
ture silicone and securing with 3 of the #8  
x 1/2" screws (black). Pipe seams should  
be facing the wall.  
ered wall, a vinyl  
siding standoff  
or furring strips  
3) Attach the 4" dia. flex liner to the vent ter-  
minal ensuring that the flex overlaps the  
collar of the vent terminal by a minimum  
of 1-3/8"(35mm). Use Mill-Pac to seal  
and secure with 3 of the #8 x 1/2" screws  
(stainless steel).  
must be used to  
ensure that the  
termination is not  
16) Attach the 90o elbow onto the pipe section  
by sealing with Mill-Pac and/or high tem-  
perature silicone and securing with 3 of the  
#8 x 1/2" screws (black).  
recessed into the  
siding. For vinyl  
siding standoff  
installation refer to the Dura-Vent  
Termination instructions.  
4) Attach the adjustable pipe section to the  
vent terminal using Mill-Pac and/or high  
temperature silicone and attach with 3 of  
the #8 x 1/2" screws (stainless steel).  
17) Slide the adjustable pipe section onto the  
90o elbow. Slide the trim collar over the  
adjustable pipe sections to cover the joint  
of the telescopic section.) The flex may  
have to be compressed back in order for  
the adjustable pipe to properly mate to  
the elbow. Seal with Mill-Pac and/or high  
temperature silicone and secure with 3 of  
the #8 x 1/2" screws (black). Pipe seams  
facing down.  
5) Slide the partially connected pipe and  
vent terminal assembly through the wall  
thimbles (from the exterior into the interior)  
and secure the cap to the exterior wall with  
4 of the supplied screws (#8 x 1-1/2" drill  
point, stainless steel). Note: pilot holes will  
need to be drilled through the wall thimble  
on all 4 corners.  
NOTE: For best results and optimum per-  
formance with each approved vent-  
ingsystem,itishighlyrecommended  
toapplyMill-Pacsealant(supplied)  
to every inner pipe connection. Fail-  
ure to do so may result in drafting  
or performance issues not covered  
under warranty. Silicone (red RTV)  
is optional.  
Note: The four screws provided for the  
vent cap should be replaced with  
appropriate fasteners for stucco,  
brick, concrete, or other types of  
sidings.  
18) Install the trim collar over the starter col-  
lar and secure with a #8 x 1/2" screw  
(black).  
Note: Thepipeseam  
should be fac-  
ing down.  
6) A bead of non-hardening mastic should  
be run around both the termination and  
vinyl siding standoff to prevent water from  
entering and to make a tight seal between  
the cap and the standoff.  
Note: To make the installation more aes-  
thetically pleasing, we recommend  
framing out a square that the cap can  
be mounted on.  
7) Stretch the 4" dia. flex liner out fully and get  
a trial fit of the liner onto the 4" dia. starter  
collar.  
If the pipe needs to be touched up, use only  
Stove Brite High Temperature Metallic Black  
Stove Paint.  
8) Cut the 4" dia. flex liner to the desired size.  
Hint: leave an extra 12" to 16" of length,  
this will make the final assembly easier to  
work with.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
INSTALLATION  
RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES  
MINIMUM HORIZONTAL TERMINATION INSTALLATIONS  
You will require the following components with your new Hampton® Direct Vent Freestanding Gas  
Stove. Please review your product to make sure you have everything you need. In the event that  
you are missing any part, contact your dealer. Decorative brass or chrome trim kits are available  
from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.  
Planning Your Venting Installation  
See the "Exterior Vent Terminal Locations"  
section for requirements.  
When planning your installation, it will be nec-  
essary to select the proper length of vent pipe  
for your particular requirements. Determine the  
minimum clearance to combustibles from the  
rear of the unit to the wall. It is also important to  
note the wall thickness. Before cutting the vent  
hole through the wall ensure that ALL vent and  
termination clearances (Refer to the "Exterior  
Vent Terminal Locations" section) will be met.  
Note: These are the minimum pieces required. Other parts may be required for your par-  
ticular installation.  
*Ifthisisanoutsidecorner,theminimumdistance  
between the vent and the outside corner is 6"  
(15cm). See "F" on the diagram in the "Exterior  
Vent Terminal Locations" section.  
Kit #640-944  
Kit #380-946  
Minimum components for a Horizontal Installation:  
640-944  
Horizontal Termination Kit which includes:  
6-5/8" Dia. x 18" Black Pipe  
1
1
1
1
1
1
4" Dia. x 18" Aluminum Vent  
946-202  
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)  
Riser Vent Terminal  
640-530/P  
640-545/P  
948-128  
Decorative Wall Trim (Black)  
Tube Mill-Pac Screws  
380-946  
Horizontal Termination Kit which includes:  
6-5/8" Dia. x 12" Black Pipe  
1
1
1
1
1
1
4" Dia. x 12" Aluminum Vent  
946-202  
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)  
AstroCap  
946-523/P  
640-545/P  
948-128  
Decorative Wall Trim (Black)  
Tube Mill-Pac Screws  
Optional Components:  
946-204  
45o Elbow - 6-5/8" Black pipe  
and 4" Aluminum Vent  
946-523/P AstroCap  
946-206 Vinyl Siding Standoff (AstroCap)  
946-205  
Vinyl Siding Shield for Riser Vent 946-506/P Vent Guard (AstroCap)  
Terminal  
946-208/P  
940  
Vent Guard (Riser Vent Terminal)  
Square Wall Thimble Cover*  
Snorkel Termination (36")*  
Snorkel Termination (14")*  
Wall Penetration  
981  
NOTE: Ensure compliance with the outside  
vent terminal location before cutting hole as  
both dimensions must be met.  
982  
942  
Heat Shield*  
* Simpson Dura-Vent Components  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
INSTALLATION  
DURA-VENT TERMINATION KIT  
important to note the wall thickness. (The  
the vent termination clearance requirements  
Planning Your Dura-Vent  
Installation  
wall thimble is suitable for 2 x 4 or 2 x 6 wall  
construction.) Select the amount of vertical  
rise desired for "vertical-to-horizontal" type  
installations.  
fromdecks,windows,soffits,gasregulators,air  
supply inlets and public walkways as specified  
inthe"ExteriorVentTerminalLocations"section  
and in your local building codes.  
There are two basic types of Dura-Vent Direct  
VentSysteminstallations:horizontaltermination  
and vertical termination. Confirm the maximum  
horizontal run and maximum vertical rise from  
the diagrams in the "Rigid Pipe Venting Sys-  
tems" section.  
Warning: Alwaysmaintainrequired  
clearances (air spaces) to nearby  
combustibles to prevent a fire  
hazard. Do not fill air spaces with  
insulation.  
To determine the length of vent pipe required  
for vertical installations, measure the distance  
from the unit flue outlet to the ceiling, the ceiling  
thickness, the vertical rise in an attic or second  
storey, and allow for sufficient vertical height  
above the roof line.  
When planning your installation, it will be nec-  
essary to select the proper length of vent pipe  
for your particular requirements. For horizontal  
installations, determine the minimum clearance  
from the rear of the unit to the wall. It is also  
Theminimumclearancerequirementsbetween  
the outer wall of the vent pipe and nearby com-  
bustiblesurfacesis1-1/4inch.Besuretocheck  
For multi-storey applications, fire stops are  
required at each floor level. If an offset is  
needed, additional pipe, elbows and supports  
will be required.  
Donotexceedthemaximumnumberofelbows.  
One 90o for horizontal terminations and two 45o  
for vertical termination.  
Alternate Horizontal  
Termination Caps  
AstroCap  
Part# 946-523/P  
Dura-Vent Basic  
Alternate  
Horizontal Kit # 970  
Horizontal  
Riser Vent  
Terminal  
1
1
1
90o Elbow  
Wall Thimble Cover  
Horiz. Sq. Term. Cap  
Part# 640-530/P  
TheFPIAstroCapTMiscertifiedforinstallationsusingFPIventingsystems  
as well as Simpson Dura-Vent® and Direct Vent GS.  
The FPI AstroCapTM is a proprietary trademark of FPI Fireplace Prod-  
ucts International Ltd.  
Dura-Vent® and Direct Vent GS are registered and/or proprietary  
trademarks of Simpson Dura-Vent Co. Inc.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
You will require the following components with  
your new Direct Vent Freestanding Gas Stove.  
Please review your product to make sure you  
have everything you need. In the event that  
you are missing any part, contact your dealer.  
Note: These are the minimum pieces re-  
quired. Other parts may be required  
for your particular installation. See  
above for a list of vent parts.  
Diagram 1  
Ifinstallingterminationonasidingcoveredwall,  
a vinyl siding standoff or furring strips can be  
used in order to ensure that the termination is  
not recessed into siding.  
Note:  
Diagram 2b  
a) The horizontal run of vent should have a  
1/4 inch rise for every 1 foot of run towards  
the termination. Never allow the vent to run  
downward. This could cause high tempera-  
tures and may present the possibility of a  
fire.  
The vinyl siding standoff is required for walls  
with vinyl siding.  
NOTE: For Snorkel terminations in ABOVE  
gradeinstallations,follownationalor  
local code requirements.  
Minimum components for a Dura-Vent Hori-  
zontal Installation:  
A) Dura-Vent Horizontal Termination Kit  
B) Wall Thimble (required for combustible  
walls)  
b) Thelocationofthehorizontalventtermination  
on an exterior wall must meet all local and  
national building codes, and must not be  
blocked or obstructed. Refer to the "Exterior  
Vent Terminal Locations" section.  
Below Grade Snorkel Installation  
If the Snorkel Termination must be installed  
below grade, i.e. basement application,  
properdrainagemustbeprovidedtoprevent  
waterfromenteringtheSnorkelTermination.  
Refer to Dura-Vent Installation instructions  
for details.. Do not attempt to enclose the  
Snorkel within the wall, or any other type of  
enclosure.  
MinimumcomponentsforaDura-VentVerti-  
cal Termination:  
c) Snorkel Terminations:  
D) Dura-Vent Vertical Termination Kit. See  
above for pipe lengths.  
For installations requiring a vertical rise  
on the exterior of the building, 14-inch and  
36-inch tall Snorkel Terminations as shown  
in Diagram 2 are available, as well as the  
standard Riser Vent. Follow the same in-  
stallation procedures as used for standard  
Horizontal Termination. NEVER install the  
snorkel upside down.  
4) Install wall penetration heat shield in the  
center of the 9-1/2" round hole and attach  
with wood screws. The four wood screws  
provided should be replaced with appropri-  
ate fasteners for stucco, brick, concrete, or  
other types of sidings. Diagram 3.  
HORIZONTAL  
TERMINATIONS  
1) Set the unit in its desired location. Check to  
determine if wall studs are in the way when  
the venting system is attached. If this is the  
case, you may want to adjust the location  
of the unit.  
*Diagram 2a: As specified in CGA B149 Instal-  
lation Code. Local codes or regulations may  
require different clearances.  
5) If installing termination on a siding covered  
wall, a vinyl siding standoff or furring strips  
must be used to ensure that the termination  
is not recessed into the siding. Diagram  
3.  
2) Assemble the desired combination of pipe  
and elbow to the appliance adapter with  
pipe seams oriented down. Offset the pipe  
seams as double seams in one place will  
cause the outer pipe to take an oval shape.  
Kit comes complete with 18" of straight vent  
-6-5/8"dia.blackouterpipeand4"dia.inner  
vent.  
6) Take the Riser Vent terminal and separate  
the Backing Plate from the Riser Vent Front  
by removing 8 screws as shown in diagram  
4.  
3) Withthepipeattachedtothestove, slidethe  
stove into its correct location, and mark the  
wall for a 9-1/2"(insidedimensions)round  
hole.Thecenteroftheroundholeshouldline  
up with the centerline of the horizontal pipe,  
as shown in diagram 1. Cut and frame the  
9-1/2 round hole in the exterior wall where  
the vent will be terminated. If the wall being  
penetrated is constructed of non-combusti-  
ble material, i.e. masonry block or concrete,  
a 7" diameter hole is acceptable.  
Diagram 2a  
Diagram 3  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
INSTALLATION  
c) Before connecting the vent pipe to the vent  
termination, slide the black decorative wall  
thimble cover over the vent pipe, then slide  
the Wall Penetration Heat Shield (Part #  
946-202) over the vent pipe. Dia. 3.  
d) Slide the appliance and vent assembly  
towards the wall carefully inserting the vent  
pipe into the riser vent terminal assembly. It  
is important that the vent pipe extends into  
the Riser Vent Backing Plate a sufficient  
distance so as to result in a minimum pipe  
overlap of 1-1/4 inches. Secure the con-  
nection between the vent pipe and the vent  
cap by attaching the two sheet metal strips  
extendingfromtheRiserVentBackingPlate  
into the outer wall of the vent pipe. Use  
two aluminum screws provided to connect  
the strips to the pipe section. Bend any  
remaining portion of the sheet metal strip  
back towards the vent cap and cut off any  
excess, it will be concealed by the decora-  
tive wall thimble cover. See diagram 5.  
VERTICAL  
TERMINATIONS  
1) Maintain the 1-1/4" clearances (air spaces)  
tocombustibleswhenpassingthroughceil-  
ings, walls, roofs, enclosures, attic rafter,  
or other nearby combustible surfaces. Do  
not pack air spaces with insulation. Check  
the "Venting Arrangement" section for the  
maximumverticalriseoftheventingsystem  
and the maximum horizontal offset limita-  
tions.  
Diagram 4  
7) InstalltheBackingPlateintothewallpenetra-  
tion heat shield and attach using 4 screws.  
Dia. 4.  
8) Connect all pipe sections to unit and install  
into wall:  
a) Measure pipe length required and cut to  
length. Hint: use the cut end of the 6-5/8"  
dia. outer pipe at the vent terminal end.  
2) Set the gas appliance in its desired loca-  
tion. Drop a plumb bob down from the  
ceiling to the position of the appliance flue  
exit, and mark the location where the vent  
will penetrate the ceiling. Drill a small hole  
at his point. Next, drop a plumb bob from  
the roof to the hole previously drilled in  
the ceiling, and mark the spot where the  
vent will penetrate the roof. Determine if  
ceiling joists, roof rafters or other framing  
will obstruct the venting system. You may  
wish to relocate the appliance or to offset,  
as shown in diagram 8 to avoid cutting load  
bearing members.  
b) Pushthepipesectionscompletelytogether,  
the minimum pipe overlap is 1-1/4". Secure  
all outer pipe joints by using at least two  
screws. Locate the screws at the bottom of  
the pipe so that the screw heads are hidden  
on the final installation.  
Diagram 5  
Note: For best results and optimum per-  
formancewitheachapprovedventing  
system, it is highly recommended to  
applyMill-Pacsealant(supplied)to  
every inner pipe connection. Failure  
to do so may result in drafting or  
performance issues not covered  
under warranty. Silicone (red RTV)  
is optional.  
8) Slide the decorative wall thimble up to the  
wall surface being careful not to scratch the  
paint. See diagram 5.  
9) Back outside: Apply sealant to the 4" inner  
flue and slide the Riser Vent Front into the  
Backing Plate and fasten with 8 screws.  
IMPORTANT:  
When connecting the pipe to the Riser  
Vent, apply Mill-Pac to the inner pipe on  
theRiserVentTerminal,aroundthebead.  
Ensure that the vent pipe is pushed past  
the bead for a secure fit.  
10) Seal around the outer edge of the Riser  
Vent Backing Plate.  
Diagram 7  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
INSTALLATION  
7) Ensure vent is vertical and secure the base  
of the flashing to the roof with roofing rails,  
slide storm collar over the pipe section and  
seal with a mastic.  
8) Install the vertical termination cap by twist  
locking it.  
Notes:  
a) For multistorey vertical installations, a  
CeilingFirestop(Part#963)isrequired  
atthesecondoor,andanysubsequent  
floor. Diagram 12. The opening should  
be framed to 10 " x 10" inside dimen-  
sions, in the same manner as shown in  
diagram 9.  
Diagram 10: The upper half of the flashing is  
installed under the roofing material and not  
nailed down until the chimney is installed. This  
allows for small adjustments.  
Diagram 8  
Note: If an offset is necessary in the attic  
toavoidobstructions,itisimportant  
tosupporttheventpipeevery3feet,  
to avoid excessive stress on the  
elbows, and possible separation.  
Wall straps are available for this  
purpose. See diagram 5.  
b) Anyoccupiedareasabovetherstoor,  
including closets and storage spaces,  
through which the vertical vent passes,  
must be enclosed.  
3) ToinstalltheRoundSupportBox/WallThim-  
ble in a flat ceiling, cut a 10 inch square hole  
in the ceiling centred on the hole drilled in  
Step 2. Frame the hole as shown in diagram  
9.  
Galvanizedpipeandelbowsmaybeutilized  
in the attic as well as above the roofline.  
The galvanized finish is desirable above  
the roofline due to its higher corrosion  
resistance.  
Continue to add pipe sections through the  
flashing until the height of the vent cap  
meets the minimum height requirements  
specified in diagram 11 or local codes.  
Notethatforsteeproofpitches, thevertical  
height must be increased. A poor draft, or  
down drafting can result from high wind  
conditions near big trees or adjoining roof  
lines, in these cases, increasing the vent  
height may solve the problem.  
Diagram 9  
4) Assemble the desired lengths of black pipe  
and elbows necessary to reach from the  
appliance adapter up though the Round  
SupportBox.Insurethatallpipesandelbow  
connections are in the fully twist-locked  
position and sealed.  
Diagram 12  
Offset Chart  
Diagram 11  
Note: For best results and optimum  
performance with each approved  
venting system, it is highly recom-  
mended to apply “Mill-Pac” sealant  
(supplied) to every inner pipe con-  
nection. Failure to do so may result  
in drafting or performance issues  
notcoveredunderwarranty.Silicone  
(red RTV) is optional.  
Roof Pitch  
Minimum Vent Height  
Feet  
2
Meters  
0.61  
0.61  
0.61  
0.76  
0.99  
1.22  
1.52  
1.83  
2.13  
2.29  
2.44  
flat to 7/12  
over 7/12 to 8/12  
over 8/12 to 9/12  
over 9/12 to 10/12  
over 10/12 to 11/12  
over 11/12 to 12/12  
over 12/12 to 14/12  
over 14/12 to 16/12  
over 16/12 to 18/12  
over 18/12 to 20/12  
over 20/12 to 21/12  
2
2
2.5  
3.25  
4
5
6
7
7.5  
8
5) Cut a hole in the roof centred on the small  
drilled hole placed in the roof in Step 2. The  
hole should be of sufficient size to meet  
the minimum requirements for clearance  
to combustibles of 1-1/4". Slip the flashing  
undertheshingles(shinglesshouldoverlap  
half the flashing) as per diagram 10.  
6) Continue to assemble pipe lengths.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
INSTALLATION  
4) Pass the flex pipe down through the center  
ofthechimneysystem,andcentertheadap-  
tor on the top of the chimney pipe. Drill four  
1/8"diameterholesthroughtheadaptorand  
into the chimney top. Insure that you are in  
fact, drilling into the metal on the chimney.  
Twist-lock the Termination Cap (Part# 980  
or 991) onto the Adaptor. (Diagram 3 and  
4).  
CONVERTING CLASS-A  
METAL CHIMNEY OR  
MASONRY CHIMNEY  
TO DIRECT  
Approved for US Installations Only  
The use of an existing chimney as an air  
intakeisnotcoveredundertheANSIZ21.88b-  
1999, CSA 2.33b-M99 test methods and the  
resulting ITS/WHI product certification. The  
code Authority Having Jurisdiction must be  
consultedpriortoproceedingwiththisinstal-  
lation method.  
VENT SYSTEM  
There are two different types of direct vent  
conversion systems listed below. Follow the  
appropriate directions for your installation.  
Converting a Factory Built Metal  
Chimney  
1) Remove the existing chimney cap.  
A) Through an existing factory built metal  
chimney going through the ceiling: A typical  
conversion of this type is shown in diagram  
1. The concept of direct vent conversion is  
to connect an adaptor to an Underwriters  
Laboratories (UL) listed 4 inch diameter  
aluminum flex pipe which is then passed  
downthroughthecenteroftheexistingmetal  
chimney system. Three sizes of Top Adap-  
tors are available from Simpson Dura-Vent.  
The Retro Connector (909B) is attached to  
the bottom of the flex pipe. The TopAdaptor  
and the Retro Connector are attached to the  
existing chimney with sheet metal screws.  
The appliance is then connected to the  
chimney with appropriate black direct vent  
pipe and an adjustable length section.  
2) Measure the distance from the top end of the  
chimney to the bottom of the ceiling support  
box, add 3" (76mm) to this measurement,  
and cut a section of the 4" flex pipe to that  
length (the flex should already be extended  
to its nominal length).  
Diagram 3  
Diagram 4  
B) Through the wall of an existing masonry  
chimney:Atypical conversion of an existing  
masonry chimney is shown in Diagram 6. A  
TopAdaptor(985K)andFlashingareusedat  
the top of the masonry chimney. The 4 inch  
aluminum liner is connected to the adaptor  
and is passed down the chimney and out  
through the masonry wall and attached  
to the Retro Connector (909B). The Retro  
Connector is attached to the masonry wall  
and then connected to the direct vent pipe  
leading to the appliance.  
5) Pull the flex pipe down through the ceiling  
supportbox,untilitprotrudesapproximately  
3"(76mm).ConnecttheexpipetotheRetro  
Connector by slipping it into the  
4-3/4" diameter sleeve on the top side of  
the Connector. Use 3 sheet metal screws  
to assemble these two parts.  
6) Push the flex pipe back up into the ceiling  
supportbox,centertheRetroConnector,and  
attach it to the support box, or decorative  
sleeve for double wall solid packed pipe,  
with the sheet metal screws (supplied).  
The holes in the Retro Connector are pre-  
punched. Diagram 5.  
Prior to installation and connection of the  
vent system to a factory-built or masonry  
chimney,thechimneymustbeinspectedand  
thoroughly cleaned by a qualified service  
person, such as a certified chimney sweep  
or home inspection service.  
The direct vent system must not be con-  
nectedtoadamagedfactory-builtormasonry  
chimney.  
Diagram 1  
3) Connect the end of the flex pipe section to  
the underside of the Top Adaptor using 3  
sheet metal screws. Diagram 2.  
For factory built, zero clearance, and ma-  
sonry chimneys cleanout doors and caps  
or plugs for cleanout tee fittings and ash  
dumps shall be secured in place and sealed  
before installing a Direct Vent system within  
the chimney.  
Diagram 2  
If the appliance shuts off during operation,  
contact a qualified service person to de-  
termine if a negative pressure and/or leaky  
chimneyconditionexists.Donotoperatethe  
appliance until the problem is corrected.  
Diagram 5  
7) The connection between the appliance and  
theRetroConnectormaybecompletedwith  
sections of black direct vent pipe, together  
with an adjustable length.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
INSTALLATION  
4) Assemble the desired lengths of Black Pipe  
and Elbows necessary to reach from the  
appliance adapter up through the support  
box and flashing to proper height as per  
Dia. 12, local codes. Ensure that all pipe  
andelbowconnectionsareintheirfullytwist  
lock position.  
IMPORTANT:ALWAYS CHECK FOR  
GAS LEAKS WITH A SOAP AND  
WATER SOLUTION OR GAS LEAK  
DETECTOR. DO NOT USE OPEN  
FLAME FOR LEAK TESTING.  
CATHEDRAL CEILINGS  
Round Support (RDS) &  
Square Support (SQS)  
If your home has a cathedral ceiling (no attic  
space between the ceiling and the roof), install  
the chimney and support as follows.  
Note: Priortoanypressuretestingofthegas  
supply piping system that exceeds  
test pressures of 1/2 psig, this ap-  
pliance must be disconnected from  
the piping system. If test pressures  
equaltoorlessthan1/2psigareused  
then this appliance must be isolated  
from the piping system by closing  
its individual manual shut-off valve  
during the testing.  
5) Ensureventisverticalandsecureashingto  
the roof with roofing nails. Slide the storm  
collar over the pipe section and seal with a  
mastic.  
1) Situate the chimney in a convenient loca-  
tion as near as possible to the appliance  
outlet. Cut and frame a hole in the roof for  
the support. The sides of this hole must be  
vertical with 1 1/4" clearance.  
6) Twist lock the vent cap on to the last sec-  
tion.  
2) Place the support in the opening. Lower it  
to the correct height as determined by the  
table and diagram below.  
Support Extensions - Round  
(RDSE) or Square (SQSE)  
Steep pitched cathedral ceilings may require  
the use of a support extension. This piece fits  
down inside the support and can be adjusted to  
increase the support's length by up to 22". The  
extension is attached to the support using the  
eight metal screws provided. Be sure there is  
at least a 2 inch overlap where the extension  
joins the support.  
H15-NG1 System Data  
For 0 to 4500 feet altitude  
Burner Inlet Orifice Sizes:  
#47  
Max. Input Rating 18,000 Btu/h  
Min. Input Rating 10,500 Btu/h  
Supply Pressure  
min.5.0" w.c.  
HIGH ELEVATION  
This unit is approved in Canada for altitude to  
4500 ft. (CAN/CGA-2.17-M91). For Natural  
Gas installations above 4500 ft. follow current  
CAN/CGA-B149.1.  
Manifold Pressure  
(High)  
3.8"+/- 0.2"w.c.  
Slope  
"X"  
H15-LP1 System Data  
0/12 - 2/12  
2/12 - 7/12  
7/12 - 12/12  
12/12 - 24/12  
24/12+  
4"  
5-1/2"  
6-3/4"  
7-1/2"  
12-1/2"  
Conversion Kit# 380-969  
GAS CONNECTION  
For 0 to 2000 feet altitude  
Thegasconnectionisa3/8"NPT90o elbow.The  
gas line can be rigid pipe or to make installation  
easier,usealistedexibleconnectorand/orcop-  
pertubingifallowedbylocalcodes. Sincesome  
municipalities have additional local codes it is  
alwaysbesttoconsultwithyourlocalauthorities  
and the CAN/CGA B149 installation codes.  
Burner Inlet Orifice Sizes:  
# 5 5  
Max. Input Rating 18,000 Btu/h  
Min. Input Rating 10,600 Btu/h  
Using a level, make sure the support is  
vertical. If the support extends above the  
roof, cut it flush with the top of the roof.  
Nailthesupporttotheframeopeningusing  
(8) 3" spiral nails or #8 x 1-1/2" screws.  
For 2000 to 4500 feet altitude  
Burner Inlet Orifice Sizes:  
# 5 6  
Max. Input Rating 15,500 Btu/h  
Min. Input Rating 8,200 Btu/h  
For USA installations follow local codes and/or  
the current National Fuel Gas Code, ANSI  
Z223.1.  
Note: If you are using a 6" square support  
you may find it difficult to screw it  
in place because it is fairly small  
inside.  
Supply Pressure  
min.12.0" w.c.  
Manifold Pressure  
(High)  
When using copper or flex connectors use only  
approvedttings.Alwaysprovideaunionsothat  
gas lines can be easily disconnected for burner  
and/orvalveservicing.Flarenutsforcopperlines  
and flex connectors are usually considered to  
meet this requirement.  
11"+/- 0.2" w.c.  
Simpson Dura-Vent has provided angle  
brackets with this support which can be  
screwed to the outside of the support  
box and nailed to surrounding framing as  
required. Use a minimum of four #8 x 1/2"  
screws per bracket. In some cases these  
brackets may need to be trimmed (e.g.:  
to fit under a flashing). Place the Finish  
Collar around the support and fasten it to  
the ceiling using the screws provided.  
3) Use appropriate roof flashing. Place the  
flashingundertheuppershinglesandontop  
of the lower shingles approximately half of  
the flashing should be under the shingles.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
INSTALLATION  
Valve Description  
GAS PIPE  
AERATION  
PRESSURE TESTING  
ADJUSTMENT  
1) Gas on/off knob  
2) Manual high/low adjustment  
3) Pilot Adjustment  
4) Thermocouple Connection  
5) Main Operator  
6) Outlet Pressure Tap (Manifold Pressure)  
7) Inlet Pressure Tap (Supply Pressure)  
8) Pilot Outlet  
The appliance must be isolated from the gas  
supply piping system by closing its individual  
manual shut-off valve during any pressure  
testing of the gas supply piping system at test  
pressures equal to or less than 1/2 psig. (3.45  
kPa). Disconnectpipingfromvalveatpressures  
over 1/2 psig.  
The air shutter can be adjusted by moving the  
adjusting wire up or down. The wire is accessed  
throughthebottom.Opentheairshutterforablue  
flame or close for a yellower flame. The burner  
aerationisfactorysetbutmayneedadjustingdue  
to either the local gas supply or altitude.  
Minimum Air Shutter Opening:  
Themanifoldpressureiscontrolledbyaregulator  
built into the gas control, and should be checked  
at the pressure test point.  
3/16"  
1/4"  
Natural Gas  
Propane  
9) Main Gas Outlet  
10) Flange Securing Screw Holes  
11) Alternative TC Connection Point  
12) Thermoelectric Unit  
CAUTION:Carbonwillbeproducedifairshutter  
is closed too much.  
Note: To properly check gas pressure, both  
inlet and manifold pressures should  
be checked using the valve pressure  
ports on the valve.  
13) Additional Valve Mounting Hole  
Note: Any damage due to carboning result-  
ing from improperly setting the aera-  
tion controls is NOT covered under  
warranty.  
1) Make sure the valve is in the "OFF" posi-  
tion.  
Note: Aeration Adjustment should only  
be performed by an authorized FPI  
Installer at the time of installation or  
service.  
2) Loosenthe"IN"and/or"OUT"pressuretap(s),  
turningcounterclockwisewitha1/8"wideat  
screwdriver.  
3) Attach manometer to "IN" and/or "OUT"  
pressure tap(s) using a 5/16" ID hose.  
4) Light the pilot and turn the valve to "ON"  
position. Read manometer.  
5) The pressure check should be carried out  
with the unit burning and the setting should  
be within the limits specified on the safety  
label.  
6) When finished reading manometer, turn  
off the gas valve, disconnect the hose and  
tighten the screw (clockwise) with a 1/8" flat  
screwdriver. Note: Screw should be snug,  
but do not over tighten  
Pull adjustment wire  
up or down to close aeration.  
Closed - Tall yellow  
Open - Short Blue  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
INSTALLATION  
CONVERSION KIT# 381-969 FROM NG TO LP  
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!  
7) Check that the screw is clean and if  
3) Remove burner by removing the 2 screws  
on each side and then slide the burner to  
the left and lift out.  
necessary remove dirt.  
Each Kit contains one LPG  
Conversion Kit and one DC  
Sparker Kit.  
8) Flip the screw (Fig. 3).  
LPG Conversion Kit Contains:  
Qty.  
1
Part #  
Description  
904-575  
918-590  
Burner Orifice #55  
Label "Converted to  
Propane"  
1
1
1
1
1
908-528  
904-529  
910-037  
918-479  
Red "LPG" label  
5/3" Allen Key  
LP Injector (Pilot Orifice)  
Instruction Sheet  
Screws  
Note: Use a magnetic type screwdriver  
if possible.  
DC Sparker Kit Contains:  
Fig.3  
Qty.  
1
Part #  
Description  
Pilot assembly  
is now  
820-475  
820-476  
904-153  
904-330  
904-438  
Bracket DC Sparker  
Bracket DC Sparker  
Washer #8 External Star  
Nut 8-32 Hex  
Plug Nylon 0.750 Hole,  
Black  
1
9) Using the Allen wrench as shown in  
Fig.4, rotate the screw clockwise until  
snug, do not overtighten.  
accessible  
for steps the  
following  
1
1
1
steps.  
1
1
2
1
1
1
904-531  
904-543  
904-553  
910-073  
910-074  
910-078  
Bushing Split Plastic  
0.500 in.  
Screw 8-32 x 3/4 Pan  
Head  
Screw #8 x 1/2 Type "B",  
Black Oxide  
4) Turn control knob to the “OFF” position.  
Spark Generator Battery  
Holder  
5) Remove the black protection cap by  
hand from the high-low knob (Fig.1).  
Spark Generator Switch  
C/W Wire  
Fig.4  
Battery Size AA  
Energizer En91  
WARNING!  
Do not overtighten the screw.  
Recommended to  
2
1
910-199  
910-903  
Clip Wire Holder  
Wire Fan To Power Cord  
Ground 30 in.  
904-781  
904-782  
Velcro Hook, Black  
Velcro Hook, Black  
grip the wrench by the short side.  
10) Verify that if the conversion is from  
NG to LPG, the screw must be  
reassembled with the red o-ring visible  
(Fig. 5).  
Installation of LPG  
Conversion Kit:  
Fig. 1  
6) Insert a 5/32” or  
4mm Allen wrench  
into the hexagonal  
key-way of the  
1) Shut off the gas supply.  
LPG Configuration  
Red o-ring visible  
2) Lift off Cast Top, remove Cast Front and  
Glass Door (refer to the glass replace-  
ment section in the manual) and carefully  
remove logs and lava rock.  
screw (Fig. 2),  
rotate it counter-  
clockwise until it is  
free and extract it.  
Fig.5  
Fig.2  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
11) Reassemble the black protection cap  
16) Reverse steps 3) to 2).  
22) Attach the DC sparker generator  
(Fig. 6).  
connector to the valve with a screw.  
17) Attach the label "This unit has been  
converted to LPG" near or on top of the  
serial # decal.  
18) Replace yellow "Natural Gas" label with  
red "LPG" label.  
Fig. 6  
Installation of the DC Sparker:  
WARNING!  
Also check that the pilot and main  
burner injectors  
are appropriate for the gas type.  
19) Remove the control panel by unscrewing  
the 2 screws.  
12) Pull off the  
pilot cap to  
23) Removethestove’srearpanelbyunscrew-  
expose the  
ing the two screws.  
pilot orifice.  
13) Unscrew the pilot orifice with the allen  
key and replace with the LP pilot orifice  
in the kit.  
20) First, remove the Piezo Ignition Wire  
from the Piezo Ignitor. Then remove the  
Piezo Ignitor from the control panel.  
24) Attach the ground wire to the grounding  
stud.  
14) Remove burner orifice with a 1/2"  
wrench and discard. Use another  
wrench to hold on to the elbow behind  
the orifice.  
21) Plug up the Piezo hole with the plastic  
bushing.  
Before  
Burner Orifice  
15) Reinstall new burner orifice LP stamped  
#55 and tighten.  
After  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30  
INSTALLATION  
25) Attach the Piezo ignition wire to the DC 29) Attach the DC sparker generator wires to  
32) Tie up the loose wire with the wire clip.  
Sparker.  
the DC sparker.  
Piezo  
Ignitor  
30) Install the supplied battery into the DC  
Sparker Box by opening the battery  
compartment.  
26) Insert both the ground wire and the DC  
sparker generator wire through the hole  
of the DC spark heat shield.  
NOTE: The battery in the DC Sparker  
Box will need to be replaced annually.  
Battery  
Compartment  
27) Install the plastic bushing over the  
outside of the hole.  
31) Attach the heat shield to the DC sparker,  
then mount onto the stove using the  
velcro already attached to the DC  
Sparker mounting bracket.  
Note: We recommend attaching the  
DC sparker box to the bottom rear of  
the stove (or place this in a convenient  
location, away from the heat source).  
Velcro  
28) Attach the ground wire to the DC spark  
mounting bracket.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31  
INSTALLATION  
LOG SET INSTALLATION  
Read the instructions below carefully and refer to the diagrams.  
If the logs are broken do not use the unit until they are replaced.  
Broken logs can interfere with the pilot operation.  
6) Place the rear log on the 2 rear log locating pins on the rear of the  
burner with the flat side to the back.  
The gas log kit contains the following:  
a) Rear Log  
b) Left Side Front Log  
c) Right Side Front Log  
d) Center Front Log  
A)  
e) Embers  
902-156  
f) Platinum Embers  
946-669 (supplied with packaged manual)  
A)  
C)  
B)  
7) Place the 2 front logs on the front log locating pins. Ensure the back  
of both logs rest against the tabs.  
1) Shut off the gas supply.  
2) Lift off Cast Top.  
B)  
3) Remove Cast Front by removing the 2 screws using a 7/16" wrench.  
Pull front out and then up as shown below.  
Inside  
view  
Left Front Log  
C)  
4) Remove Glass Door.  
Right Front Log  
5) Carefully remove the logs from the unit and unwrap them. The logs  
are fragile, handle with care - do not force into position.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
8) Take the embers and place on the burner in the space between the  
2 front logs, ensure not to cover any burner ports. Do not put embers  
on the burner in the area between the front logs and the rear log.  
See photo below.  
9) Place the center cross log on the locating pin in the top of the rear  
log and position as shown below.  
Logs must be oriented as shown below.  
Separate platinum embers and place at the front of the burner in  
and around where the embers are placed. Avoid stacking platinum  
embers.  
A)  
D)  
A)  
B)  
C)  
10) Test fire to ensure proper light off (make sure flame flows smoothly  
from one end of burner to the other). If there is any flame hesitation,  
check that area for any blockage of the burner ports.  
11) Re-install the Glass Front, Cast Front and Top.  
A)  
B)  
D)  
C)  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
OPTIONAL REMOTE  
CONTROL  
FINAL CHECK  
Before leaving this unit with the customer, the  
installer must ensure that the appliance is firing  
correctly. This includes:  
OPTIONAL  
WALL THERMOSTAT  
UsetheHampton® RemoteControlKitapproved  
for this unit. Use of other systems may void  
your warranty.  
A wall thermostat may be installed if desired.  
Connect the wires as per the wiring diagrams.  
Note that the wires are connected to the "TH"  
on the gas valve. Use table below to determine  
the maximum wire length:  
1) Clocking the appliance to ensure the cor-  
rect firing rate (rate noted on label) at 15  
minutes.  
The remote control kit comes with a hand held  
transmitter, a receiver and a wall mounting  
plate.  
2) Ifrequired,adjustingtheprimaryairtoensure  
that the flame does not carbon. First allow  
the unit to burn for 15 min. to stabilize.  
Note:Preferableifthethermostatisinstalled  
on an interior wall.  
3) Check for proper draft.  
Hampton® offers an optional programmable  
thermostat but any 250-750 millivolt rated non-  
anticipator type thermostat that is CSA, ULC or  
UL approved may be used.  
CAUTION  
1) Choose a convenient location on the wall  
to install the receiver and the receptacle  
box (protection from extreme heat is very  
important). Run wires from the fireplace to  
that location, use Thermostat Wire Table.  
Any alteration to the product that causes  
sootingorcarboningthatresultsindamage  
to the exterior facia is not the responsibility  
of the manufacturer.  
CAUTION  
Do not connect the millivolt  
wall thermostat wires  
to the 120V wires.  
2) Connect the wires as per the wiring diagram  
below.  
Thermostat Wire Table  
CAUTION  
Recommended Maximum Lead Length  
(Two-Wire) When Using Wall  
Thermostat (CP-2 System)  
Do not connect the  
millivolt remote control wires  
to the 120V wires.  
Wire Size  
Max. Length  
14 GA.  
16 GA.  
18 GA.  
20 GA.  
22 GA.  
50 Ft.  
32 Ft.  
20 Ft.  
12 Ft.  
9 Ft.  
3) Install3AAAalkalinebatteriesintransmitter  
and 4 AA alkaline batteries in the receiver.  
Install the receiver and its cover in the wall.  
Switch the remote receiver to "remote"  
mode. The remote control is now ready for  
operation.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34  
INSTALLATION  
WIRING DIAGRAMS  
If any of the original wires as supplied with the  
appliancemustbereplaced, itmustbereplaced  
with CSA type SEW (200oC) or its equivalent.  
Caution: Ensure that the wires do  
not touch any hot surfaces and are  
away from sharp edges.  
CAUTION: Label all wires prior  
to disconnection when servicing  
controls. Wiring errors can cause  
improper and dangerous opera-  
This heater does not require a 120V A.C. sup-  
ply for operation. In case of a power failure, the  
burner switch and the optional remote control/  
thermostat will continue to operate. However,  
a 120V A.C. power supply is needed for the  
fan/blower operation.  
For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes  
WARNING: Electrical Grounding Instructions  
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should  
be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from  
this plug.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
For PROPANE Units and Units Equipped with DC Spark Boxes*  
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
IMPORTANT: Gas on/off knob cannot be  
the first time you use it with the fan on. When  
first operated, the unit will release an odour  
caused by the curing of the paint and the burn-  
ing off of any oils remaining from manufactur-  
ing. Smoke detectors in the house may go off  
at this time. Open a few windows to ventilate  
the room for a couple of hours. The glass may  
require cleaning.  
OPERATING  
turned from "PILOT" to "OFF" unless it is  
partially depressed.  
INSTRUCTIONS  
1) Read and understand these instructions  
1) TurnstoveOFFusingtheBurner"ON/OFF"  
switch remote or thermostat. Switches are  
located at the top right hand corner (rear)  
of the stove.  
before operating this appliance.  
2) Check to see that all wiring is correct and  
enclosed to prevent possible shock.  
DO NOT ATTEMPT TO CLEAN THE GLASS  
WHILE IT IS STILL HOT!  
3) Check to ensure there are no gas leaks.  
4) Make sure the glass in the door frame is  
properly positioned. Never operate the ap-  
pliancewiththeglassremoved.Neverstrike  
the glass.  
Note: When the glass is cold and the appli-  
anceislit,itmaycausecondensation  
andfogtheglass. Thiscondensation  
is normal and will disappear in a few  
minutes as the glass heats up.  
5) Verify that the venting and cap are unob-  
structed.  
During the first few fires, a white film  
may develop on the glass front as part  
of the curing process. The glass should  
be cleaned or the film will bake on and  
become very difficult to remove. Use a  
non-abrasive cleaner and NEVER clean  
the glass while it is hot.  
2) Turn gas control knob so indicator points  
to "OFF" position and allow 5 minutes for  
any gas in the combustion chamber to  
escape.  
6) Verify log placement. If the pilot cannot be  
seen when lighting the unit - the logs have  
been incorrectly positioned.  
7) The unit should never be turned off, and on  
again without a minimum of a 60 second  
wait.  
3) Turn gas control knob counterclockwise  
so indicator points to the "PILOT" posi-  
tion. Depress the gas control knob fully.  
Depress the igniter button several times  
untilthepilotlights.Afterapproximatelyone  
minute, release the gas control knob. The  
pilot flame should continue to burn. If the  
pilot does not remain lit, repeat operation  
allowing a longer period before releasing  
gas control knob.  
ADJUSTING FLAME  
HEIGHT  
Your heater has an adjustable flame to tailor the  
look and heat output to your specific needs. It  
is adjusted by turning the flame adjustment dial  
on the gas control valve.  
4) When the pilot stays lit, turn the gas knob  
further counterclockwise to the "ON" posi-  
tion.  
Turn clockwise to adjust the flame higher, coun-  
terclockwise for a lower flame.  
5) Use the thermostat or remote control to  
turn on the unit.  
6) Rotate the flame height regulator to adjust  
the flame height higher or lower.  
LIGHTING  
SHUTDOWN  
PROCEDURE  
PROCEDURE  
IMPORTANT  
To ignite or reignite the pilot,  
the door to the firebox must  
be opened.  
1) Use the thermostat or remote control to  
turn off the main burner.  
2) Turn the main gas control clockwise to the  
"OFF" position to turn off the pilot (push  
knob in slightly).  
AUTOMATIC  
CONVECTION FAN  
OPERATION  
NOTE: For all propane units and units  
equipped with electric spark boxes,  
see "Copy of Lighting Plate Instruc-  
tions" section for more details.  
3) Turn off all electric power to appliance if  
service is to be performed.  
Thefanoperatesautomatically-turntheknobat  
the top right rear corner to adjust to the desired  
speed. The fan will turn on as the stove comes  
up to operating temperature. After the unit has  
been turned off and the unit cooled to below a  
useful heat output range the fan will shut off  
automatically.  
Only when the pilot holds, without pressure  
being applied to the control knob, should the  
door to the firebox be closed. The unit must  
never be operated with the glass or door  
open.  
FIRST FIRE  
The FIRST FIRE in your stove is part of the  
paint curing process. To ensure that the paint  
is properly cured, it is recommended that you  
burn your fireplace for at least four (4) hours  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
37  
OPERATING INSTRUCTIONS  
COPY OF THE LIGHTING PLATE INSTRUCTIONS  
FOR YOUR SAFETY READ BEFORE LIGHTING  
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/  
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)  
WARNING:Ifyoudonotfollowtheseinstructionsexactly,areorexplosionmayresultcausingpropertydamage,  
personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause  
injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance  
or additional information consult a qualified installer, service agency or gas supplier.  
A) This appliance has a pilot which must be lighted by hand, following the instructions below exactly.  
B) BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than  
air and will settle on the floor.  
WHAT TO DO IF YOU SMELL GAS  
- Do not try to light any appliance  
- Do not touch any electric switch, do not use any phone in your building  
- Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.  
- If you cannot reach your gas supplier, call the fire department.  
C) Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to  
repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.  
D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and  
to replace any part of the control system and any gas control which has been under water.  
E) This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.  
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures  
keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner  
and control compartment clean. See installation and operating instructions accompanying appliance.  
LIGHTING INSTRUCTIONS  
STOP! Read the safety information above on this label.  
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK:  
FOR ALL PROPANE UNITS AND  
UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:  
1) Push in gas control knob slightly and turn clockwise  
to  
“OFF”. Knob cannot be turned from “PILOT” to “OFF” unless  
knob is pushed in slightly. Do not force.  
1) Push in gas control knob slightly and turn to “PILOT” position.  
OFF  
PILOT BURNER  
VEILLEUSE  
2) Push in control knob all the way and hold in until the pilot lights  
up. Continue to hold the control knob in for about 20 seconds  
after the pilot is lit. Release knob.  
THERMOPILE  
Gas Inlet  
ELEMENT  
3) Push in gas control knob slightly and turn to "ON" position.  
THERMO-  
ELECTRIQUE  
4) Turn ON the flame switch.  
2) Wait five (5) minutes to clear out any gas. If you then smell gas  
STOP! follow “B” in the safety information above on this label. If  
you don’t smell gas, go to the next step.  
Gas Inlet  
3) Turn knob on gas control counterclockwise  
to “PILOT”.  
4) Push in control knob all the way and hold in. Immediately push  
black button on spark igniter until pilot lights. Continue to hold the  
control knob in for about 1/2 minute after the pilot is lit. Release  
knob and it will pop back up. Pilot should remain lit. If it goes out,  
repeat steps 3) and 4).  
If knob does not pop up when released, stop and immediately call  
your service technician or gas supplier.  
If the pilot will not stay lit after several tries, turn the gas control  
knob to “OFF” and call your service technician or gas supplier.  
5) Turn gas control knob counterclockwise  
6) Use rocker switch to operate main burner.  
to “ON”.  
TO TURN OFF GAS APPLIANCE  
1) Turn off the flame switch.  
2) Push in the gas control knob slightly and turn clockwise  
to “OFF”. Do not force.  
3) Turn off all electric power to the appliance if service is to be performed.  
You may shut off the pilot during prolonged non use periods to conserve fuel.  
DO NOT REMOVE THIS INSTRUCTION PLATE  
918-474a  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
38  
MAINTENANCE  
2) Clean glass (never when unit is hot), appli-  
ance, and door with a damp cloth. Never  
use an abrasive cleaner.  
NORMAL OPERATING  
SOUNDS OF GAS  
APPLIANCES  
It is possible that you will hear some sounds  
fromyourgasappliance.Thisisperfectlynormal  
due to the fact that there are various gauges  
and types of steel used within your appliance.  
Listedbelowaresomeexamples.Allarenormal  
operatingsoundsandshouldnotbeconsidered  
as defects in your appliance.  
CAUTION:ANYSAFETYSCREEN  
OR GUARD REMOVED FOR  
SERVICING AN APPLIANCE  
MUST BE REPLACED PRIOR TO  
OPERATING THE APPLIANCE.  
3) Theheaterisnishedinaporcelainnishor  
with a heat resistant paint and should only  
be refinished with heat resistant paint (not  
with wall paint).  
CLOTHING OR OTHER FLAM-  
MABLEMATERIALSHOULDNOT  
BE PLACED ON OR NEAR THE  
APPLIANCE.  
Never use an abrasive cleaner on the por-  
celain finish as it may scratch the surface.  
4) Make a periodic check of burner for proper  
position and condition. Visually check the  
flameoftheburnerperiodically,makingsure  
the flames are steady; not lifting or floating.  
If there is a problem, call a qualified service  
person.  
8) Each time the appliance is lit, it may cause  
condensation and fog the glass. This  
condensation and fog is normal and will  
disappear in a few minutes as the glass  
heats up.  
Blower:  
Hampton® gasappliancesusehightechblowers  
to push heated air farther into the room. It is not  
unusual for the fan to make a "whirring" sound  
when ON. This sound will increase or decrease  
in volume depending on the speed setting of  
your fan speed control.  
5) Caution: Label all wires prior to discon-  
nection when servicing controls. Wiring  
errors can cause improper and danger-  
ous operation.  
Never operate the appliance without the  
glass properly secured in place.  
Burner Tray:  
9) Periodically check the pilot flames. Correct  
flamepatternhasthreestrongblueames:1  
flowing around the thermopile and 1 around  
the thermocouple, and 1 flowing across the  
rear of the burner (it does not have to be  
touching the burner).  
The burner tray is positioned directly under the  
burner tube(s) and logs and is made of a differ-  
ent gauge material from the rest of the firebox  
and body. Therefore, the varying thicknesses of  
steelwillexpandandcontractatslightlydifferent  
rates which can cause "ticking" and "cracking"  
sounds. You should also be aware that as there  
are temperature changes within the unit these  
sounds will likely re-occur. Again, this is normal  
for steel fireboxes.  
6) The appliance and venting system must be  
inspected before use, and at least annually,  
byaqualifiedeldserviceperson,toensure  
that the flow of combustion and ventilation  
air is not obstructed.  
Note: If you have an incorrect flame pat-  
tern, contact your Hampton® dealer  
for further instructions.  
During the annual service call, the burner  
should be removed from the burner tray  
and cleaned. Replace the embers but do  
not block the pilot.  
Blower Thermodisc:  
7) Keep the area near the appliance clear and  
free from combustible materials, gasoline,  
and other flammable vapours and liquids.  
When this thermally activated switch turns ON  
it will create a small "clicking" sound. This is the  
switch contacts closing and is normal.  
PILOT ADJUSTMENT  
Pilot Flame:  
WARNING:CHILDRENANDADULTS  
While the pilot flame is on it can make a very  
slight "whisper" sound.  
SHOULD BE ALERTED TO THE  
HAZARDS OF HIGH SURFACE  
TEMPERATURE AND SHOULD  
STAYAWAYTOAVOIDBURNSOR  
CLOTHING IGNITION. YOUNG  
CHILDREN SHOULD BE CARE-  
FULLY SUPERVISED WHEN  
THEY ARE IN THE SAME ROOM  
AS THE APPLIANCE.  
Gas Control Valve:  
As the gas control valve turns ON and OFF, a  
dullclickingsoundmaybeaudible,thisisnormal  
operation of a gas regulator or valve.  
Unit Body/Firebox:  
Different types and thicknesses of steel will  
expand and contract at different rates resulting  
in some "cracking" and "ticking" sounds will be  
heard throughout the cycling process.  
Top View of pilot flame  
Incorrect flame pattern will have small, probably  
yellow flames, not coming into proper contact  
with the rear of the burner or thermopile.  
DO NOT USE THIS APPLIANCE  
IFANYPART HAS BEEN UNDER  
WATER. IMMEDIATELY CALL A  
QUALIFIED SERVICE TECHNI-  
CIAN TO INSPECT THE APPLI-  
ANCE AND TO REPLACE ANY  
PART OF CONTROL SYSTEM  
ANDANYGASCONTROLWHICH  
HAS BEEN UNDER WATER.  
MAINTENANCE  
INSTRUCTIONS  
1) Always turn off the valve before cleaning.  
For relighting, refer to lighting instructions.  
Keep the burner and control compartment  
clean by brushing and vacuuming at least  
once a year. When cleaning the logs, use a  
soft clean paint brush as the logs are fragile  
and easily damaged.  
Top View of pilot flame  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
MAINTENANCE  
FAN MAINTENANCE  
Ifyourfanrequiresmaintenanceorreplacement,  
access to the fan is through the rear access  
panel on the back of the unit.  
GENERAL VENT  
MAINTENANCE  
Conduct an inspection of the venting system  
semi-annually. Recommended areas to inspect  
as follows:  
GLASS REPLACEMENT  
Your stove is supplied with high temperature, 5  
mmNeoceramceramicglassthatwillwithstand  
the highest heat that your unit will produce. In  
the event that you break your glass by impact,  
purchase your replacement door from an au-  
thorized Hampton® dealer only, and follow our  
step-by-step instructions for replacement.  
IMPORTANT: These fans collect a lot of  
dust from within your home. Ensure you  
maintainthesefanmotorsonaregularbasis  
by vacuuming out the fan squirrel cages,  
around the motor, and around the grills on  
the back of the stove.  
1) Check the Venting System for corrosion in  
areas that are exposed to the elements.  
These will appear as rust spots or streaks,  
and in extreme cases, holes. These com-  
ponents should be replaced immediately.  
1) Lift off Cast Top.  
2) Remove the Cap, and shine a flashlight  
down the Vent. Remove any bird nests, or  
other foreign material.  
WARNING:  
Electrical Grounding Instructions  
This appliance is equipped with a  
three pronged (grounding) plug for  
yourprotectionagainstshockhazard  
and should be plugged directly into  
a properly grounded three-prong  
receptacle. Do not cut or remove the  
grounding prong from this plug.  
3) Checkforevidencesofexcessivecondensa-  
tion, such as water droplets forming in the  
innerliner,andsubsequentlydrippingoutthe  
joints, Continuous condensation can cause  
corrosion of caps, pipe, and fittings. It may  
becausedbyhavingexcessivelateralruns,  
toomanyelbows,andexteriorportionsofthe  
system being exposed to cold weather.  
IMPORTANT  
Disconnect power supply  
before servicing  
4) Inspect joints, to verify that no pipe sections  
or fittings have been disturbed, and conse-  
quently loosened. Also check mechanical  
supports such as Wall Straps, or plumbers'  
tape for rigidity.  
2) Open the 2 latches to remove Glass Front.  
Angle out and then lift, same as Cast  
Front.  
5) Verify proper operation after servicing.  
LOG REPLACEMENT  
Theunitshouldneverbeusedwithbrokenlogs.  
Turn off the gas valve and allow the unit to cool  
before opening door to carefully remove the  
logs. The pilot light generates enough heat to  
burn someone. If for any reason a log should  
need replacement, you must use the proper  
replacement log. The position of these logs  
must be as shown in the diagram under Log  
Installation.  
Latches  
3) Remove glass and replace with new  
glass.  
4) Re-install Cast Top.  
Note: Improper positioning of logs may  
create carbon build-up and will alter  
the unit’s performance which is not  
covered under warranty.  
WARNING:Donotoperateappliance  
with glass panel removed, cracked  
orbroken.Replacementoftheglass  
should be done by a licensed or  
qualified service person.  
Note: Wearing gloves will protect your  
hands while handling glass.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
40  
MAINTENANCE  
9) Remove burner by removing the 2 screws  
on each side, slide the burner to the left and  
then lift the burner tray out.  
12) To remove the valve, remove the 4 screws  
(2 per bracket) that hold the valve to the  
valve bracket assembly.  
REMOVING VALVE  
If your valve requires maintenance or replace-  
ment, use the following instructions:  
13) To replace the burner tray assembly, simply  
reverse these instructions.  
Note: Alwayscloseoffthegassupplybefore  
removing the valve.  
To remove valve from valve assembly,  
continue.  
1) If optional fan is installed, disconnect power  
source to stove.  
14) Remove two (2) thermopile wires.  
2) Remove access panel.  
15) Removethermocouplewitha9mm(metric)  
wrench.  
Screws  
16) Remove pilot nut with an 11 mm wrench.  
17) Remove valve to orifice nut with a 13/16"  
Note: Use a magnetic type screwdriver if  
possible.  
wrench.  
18) Remove inlet pipe with pipe wrench. Note  
10) Removeall8screwsholdingtheburnertray  
orientation of 90o elbow.  
assembly in place. Remove deflector.  
19) Remove two (2) phillips head M5 screws on  
3) Disconnect gas line to stove.  
each side of the valve.  
4) Disconnect 3/8" NPT pipe from 90o elbow  
20) Removevalveandremovegasout90o brass  
on valve or flex connector.  
fitting. Note orientation of fitting.  
5) Disconnect the two (2) switch wires from  
valve.  
INSTALLING  
VALVE ASSEMBLY  
1) To install a new valve assembly, reverse  
instructions for Removing Valve.  
11) Carefully lift the burner tray assembly out.  
2) Checkforleaksandmanifoldpressure. See  
Gas Pressure Test instructions.  
3) To reinstall valve, reverse instructions for  
removing valve assembly, steps 11-20.  
6) Disconnect piezo wire.  
7) Lift off Cast Top, remove Cast Front and  
removeGlassDoor.Seethe"GlassReplace-  
ment" section for removal instructions.  
8) Carefully remove the logs and embers.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
41  
PARTS LIST  
MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
Part #  
Description  
20) 380-012  
25) 910-330  
26) 904-569  
28) 910-241  
29) 260-037  
Rear Panel  
1)  
2)  
3)  
942-601** Casting - Top  
47) 380-011  
50) 948-255  
Restrictor  
Fan Speed Control (120V)  
Knob - Fan Speed Control  
Burner ON/OFF Switch  
Rear Control Panel  
942-621** Casting - Side & Leg  
942-611** Casting - Front  
Latch Ojop W/J-Hook  
51) 940-338/P Replacement Glass  
52) 41225  
53) 380-008  
54) 380-007  
Gasket Tadpole  
Glass Bracket  
Door Frame  
6)  
7)  
8)  
9)  
770-066F Top Relief Plate  
W260280 Top Relief Plate Gasket  
770-067F Plate Insulation Holder  
35) 380-002  
36) 380-003  
38) 380-034  
Firebox Bracket - Left  
Firebox Bracket - Right  
Casting Mount Bracket  
56) 910-157/P Fan Motor (120 V)  
942-117  
Top Relief Frame  
57) 910-794  
918-516  
Power Cord (120 V)  
Manual  
10) W260260 Top Relief Frame Gasket  
11) 945F  
Dura-Vent Collar  
45) 380-001  
46) 380-010  
Door Support  
Baffle Plate of Firebox  
12) W842051 Gasket for Flue Adaptor  
13) W260108 Gasket for Inner Flue  
* Not available as a replacement part.  
14)  
*
Rear Bracket  
** Last digit of part number represents colour:  
3=Slate Blue, 4=Ivory, 5=Timberline Brown.  
15) 380-024  
16) 380-023  
17) 910-142  
Fan Deflector - Right  
Fan Deflector - Left  
Thermodisc Switch  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
42  
PARTS LIST  
BURNER & LOG ASSEMBLY  
Part #  
Description  
380-574/P Valve/Pilot Assembly - S.I.T. - NG  
60) 910-478  
Valve S.I.T. - NG/LPG  
#47 Orifice - NG  
904-434  
63) 910-190  
64) 908-672  
65) 490-061  
936-170  
Piezo Ignitor & Nut  
Control Panel Decal  
Switch Plate  
Orifice Gasket  
66) 910-038  
910-039  
67) 380-013  
Pilot Assy-S.I.T. - 3 ame - NG  
Pilot Assy-S.I.T. - 3 ame - LP  
Pilot Holder  
68) W840470 Pilot Assembly Gasket  
69) 380-019  
73) 380-032  
74) 380-033  
75) 380-930  
80) 380-505  
88) 380-015  
Valve Shield  
Valve Plate  
Valve Door  
Log Set  
Burner Assembly - NG  
Burner Box Gasket  
Air Shutter  
89)  
90)  
*
*
Burner Box  
381-969  
Conversion Kit - NG to LP  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
43  
NOTES  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
44  
NOTES  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46  
WARRANTY  
Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit  
thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of  
a Hampton Product. This warranty is not transferable.  
The Warranty: Limited Lifetime  
External casting, not directly in contact with the fire, such as hobs, sides, ash lips, legs, fronts and fire doors, are covered against cracks and warps resulting from manufacturer  
defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.  
The combustion chamber, heat exchanger, burner tubes/pans and logs are covered under the Limited Lifetime Warranty for five (5) years for parts and subsidized labour*  
and parts only thereafter.  
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.  
Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly  
components, and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are  
considered repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from  
date of replacement.  
FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.  
Simpson Dura-Vent venting components are covered by Simpson Dura-Vent Inc. warranty.  
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any  
item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.  
Conditions:  
Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days  
of installation. Reported damage after this time will be subject to rejection.  
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent  
provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.  
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated  
for manufacturer defect.  
The authorized selling dealer is responsible for all in-field service work carried out on your Hampton product. FPI will not be liable for results or costs of workmanship from  
unauthorized service persons or dealers.  
At all times FPI reserves the right to inspect product in the field which is claimed to be defective.  
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name,  
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.  
Exclusions:  
This limited Lifetime Warranty does not extend to or include paint (charcoal units), porcelain (including pinholes, scratches and minor shade mismatch), door or glass  
gasketing or trim.  
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufac-  
tured. ie. as products evolve, field modifications or upgrades will not be performed.  
FPI will not be liable for travel costs for service work.  
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.  
Embers, door and glass, gaskets, door handles, paint are not covered under the terms of this warranty policy.  
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.  
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence  
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical  
systems such as furnaces, fans, clothes dryer, etc.  
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.  
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.  
Performance problems due to operator error will not be covered by this warranty policy.  
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your war-  
ranty on this product.  
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.  
* Subsidy according to job scale as predetermined by FPI.  
Hampton® H15-1 Direct Vent Freestanding Gas Stove  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hampton® fireplace products are designed with  
reliability and simplicity in mind. In addition, our  
internalQualityAssuranceTeamcarefullyinspects  
each unit thoroughly before it leaves our door.  
FPIFireplaceProductsInternationalLtd.ispleased  
to extend this Limited Lifetime Warranty to the  
original purchaser of a Hampton® Product.  
See the inside back cover for details.  
Register your Hampton® online at  
Installer: Please complete the following information  
Dealer Name & Address:______________________________________________  
___________________________________________________________________  
Installer: ___________________________________________________________  
Phone #: ___________________________________________________________  
Date Installed: ______________________________________________________  
Serial No.:__________________________________________________________  
Hampton is a trademark of FPI Fireplace Products International Ltd.  
© Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved.  
Printed in Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Haier Washer HW70 B14266 User Manual
Hamilton Beach Coffeemaker 49981 User Manual
Hamilton Beach Frozen Dessert Maker 68771 User Manual
HANNspree Flat Panel Television MAK 000001 User Manual
HP Hewlett Packard Computer Accessories 5992 3193 User Manual
HP Hewlett Packard Computer Drive 1000ux User Manual
HP Hewlett Packard Projector xb31 sb21 User Manual
IBM Printer V03 User Manual
iLive MP3 Docking Station IBP182B User Manual
Image Treadmill IMTL11900 User Manual