HP Hewlett Packard Switch TA688 96138 User Manual

HP StoreVirtual Storage VSA Installation and  
Configuration Guide  
Abstract  
This guide provides information about installing and configuring the HP StoreVirtual VSA for VMware vSphere and the HP  
StoreVirtual VSA for Microsoft Hyper-V. Included are network configuration best practices to ensure the best performance for  
the SAN using the VSAs. The intended audience is system administrators responsible for managing HP StoreVirtual Storage  
using VSAs.  
HP Part Number: TA688-96138  
Published: March 2013  
Edition: 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Contents  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Planning for the VSA  
Careful planning of the virtual network configuration, the VSA configuration, and the configuration  
of the clusters and volumes for data storage ensures that you can take full advantage of the features  
and benefits of the HP StoreVirtual Storage.  
Planning the virtual network configuration  
Before you install the VSA on the network, plan the virtual network configuration, including the  
following areas:  
Design and configuration of the virtual switches and network adapters.  
VSA directories, host names and IP addresses.  
Virtual network configuration, including the subnet and the virtual IP addresses for iSCSI  
access.  
For more detailed information, see “Designing a virtual SAN ” (page 20).  
Planning the clustered storage configuration  
When you install the HP StoreVirtual Centralized Management Console, you should plan and  
configure the storage system features, such as email alert notification, before you configure the  
data storage.  
Planning the virtual network configuration  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2 Installing the HP StoreVirtual VSA for VMware vSphere  
The VSA is pre-formatted for use with HP StoreVirtual VSA for VMware vSphere. If you are using  
an evaluation copy, and you want to continue using the VSA after the trial period has ended, you  
must purchase a license key. After you apply the license key, your configuration can be used as  
is in a production environment, or reconfigured if necessary.  
Supported versions of VMware  
VMware vSphere 5; ESXi Server version 5.x for LeftHand OS 9.0 or later  
NOTE: If you are running LeftHand OS version 9.0, VMware vSphere 4 and ESX/ESXi Server  
4.x are also supported.  
Prerequisites  
Available drive space of up to 10 TB for ESX Server. HP recommends installing ESX Server  
on top of a redundant RAID configuration. Do not use RAID 0.  
4 GB memory available for running the HP StoreVirtual VSA for VMware vSphere installer.  
Applicable memory reserved based on total disk capacity (Table 1 (page 6)).  
Table 1 Reserve physical memory for VSA for vSphere disks  
Total capacity of all installed disks  
5 GB to 500 GB  
Requires at least this much memory  
3 GB  
4 GB  
5 GB  
500 GB to 5 TB  
5 TB to 10 TB  
Microsoft .Net 2.0 or later on the installer client.  
vCenter and ESX servers properly licensed before connecting to them using the HP StoreVirtual  
VSA for VMware vSphere installer.  
A Gigabit Ethernet or internal network environment, including the following:  
A host name for the VSA for vSphere  
A network configuration plan, including reserved IP addresses, subnet mask, and gateway  
for the VSA, or use DHCP (requires statically assigned IP addresses)  
Installing the HP StoreVirtual VSA for VMware vSphere  
Install the VSA for vSphere using any of the following methods:  
Download the VSA for vSphere from either of these HP websites:  
or  
Install the VSA for vSphere from the HP StoreVirtual VSA and Failover Manager DVD.  
The installer for the VSA for vSphere includes a wizard that guides you through configuring the  
virtual machine on the network, configuring virtual or physical hard drives, and powering on the  
VSA. The installer checks for the current CMC, and then installs it, if it is not on the system.  
6
Installing the HP StoreVirtual VSA for VMware vSphere  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
NOTE: If a prior version CMC is installed on a management computer on the network, the VSA  
for vSphere installer updates the CMC to the current version in the same location. The user-specified  
location entered in the installer wizard is ignored.  
NOTE: You cannot run concurrent installations of VSA with the same VSA name on one ESX  
server.  
After the installation is complete, open the CMC and find the VSAs as storage systems in the CMC.  
You can then set up the clustered storage for the SAN, as described in “Getting started with HP  
Table 2 Configuring the VSA for vSphere using the installer wizard  
Installer step  
Definition  
Host Setup  
ESX Server or vCenter Server that will host the VSA. Enter either the IP address or host name of  
the server.  
Select Host  
Lists ESX hosts managed by the vCenter Server or ESX Server, and lists health status and  
configuration details for the host. Select the specific host on the server that was entered in the first  
step.  
Type  
Virtual Storage Appliance (VSA) is the storage system. See the HP StoreVirtual Storage User Guide  
for information about installing the Failover Manager (FOM).  
Datastore  
Network  
List of datastores available on the server. Select the desired datastore to host the virtual appliance  
files.  
Network settings include the following information:  
DNS name for the VSA. Name for the VSA must be 80 characters or less. Valid characters  
include a-z (case insensitive), 0–9, and –.  
NIC to configure. Available NICs are eth0 and eth1. The VSA can support up to two NICs.  
IP address  
Reserved IP address is recommended. Enter the IP address, subnet mask, and gateway.  
DHCP is available (requires statically assigned IP addresses).  
The network interface designated for the virtual machines. Select the appropriate interface  
from the list.  
The NIC designated as the preferred interface for LeftHand OS. Select eth0 or eth1.  
Virtual Machine  
Information for creating the virtual machine, including the following:  
Name for the virtual machine in ESX Server or vCenter Server  
Type of data drives, virtual or raw  
VMDK or Raw  
Disk  
One of two windows opens, depending on which type of drives were selected in the Virtual  
Machine window.  
Virtual or raw drive requirements  
Maximum of 5 drives  
Minimum size: 5 GB  
Maximum size: 2047 GB  
Virtual hard drives window  
Select up to 5 virtual hard drives and designate the size.  
Raw Disk window  
Select up to five raw disks that you have prepared, and which are available. These drives must  
have no partitions or volumes on them, or the installer will not list them.  
IMPORTANT: The raw disk can be greater than 2 TB in VMware. However, the total amount of  
configured storage on the VSA cannot exceed 10 TB or virtual RAID configuration will fail.  
Installing the HP StoreVirtual VSA for VMware vSphere  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1. Begin the installer one of the following ways:  
Insert the HP StoreVirtual Management Software DVD in the DVD drive.  
Double-click the executable that you downloaded to start the installation.  
2. Click Install VSA for VMware vSphere to begin the wizard.  
3. In the Meta Launcher command line window that opens, enter 1 to run the installer CLI, or  
enter 2 to run the installer GUI. Both versions require the same information and perform the  
same installation.  
If you selected the GUI installation in the Meta Launcher CLI window, the GUI installer  
window opens again and you click Install VSA for VMware for vSphere again to begin  
the wizard.  
4. If necessary, enter the login credentials to allow the installer to configure the VSA for vSphere  
on the vSphere server, and click Yes.  
5. Accept the terms of the License Agreement again.  
6. Work through the wizard to configure the parameters of the virtual machine on the network,  
including the hard drives. See Table 2 (page 7).  
NOTE: Run the wizard again to configure another VSA for vSphere using the same parameters  
as appropriate.  
7. Finish the installation, reviewing the configuration summary, and click Deploy.  
When the installer is finished, the VSA for vSphere is ready to be used in the HP StoreVirtual  
Storage.  
8. Next, use the Find function in the CMC to discover the VSA for vSphere, and then add it to  
a management group.  
Installing the VSA OVF version  
Import the VSA for vSphere OVF version as a virtual appliance through the Virtual Infrastructure  
Client. Download the .ovf files from the website:  
When you import the VSA for vSphere you must perform the following tasks:  
Configure the data disk(s).  
Power on the VSA for vSphere and set the IP address and host name of the VSA for vSphere.  
Configuring a data disk  
When you configure the data disk, use Table 3 (page 8) to determine the proper size for the  
disk. The maximum disk size on the ESX Server is limited by the block size used to format the  
datastore.  
Table 3 Relationship of disk size to datastore block size  
Block Size  
VMFS5 only  
1 MB (default)  
VMFS3 only  
1 MB  
Max VMDK  
up to 2 TB  
256 GB  
512 GB  
2 MB  
8
Installing the HP StoreVirtual VSA for VMware vSphere  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Table 3 Relationship of disk size to datastore block size (continued)  
Block Size  
4 MB  
Max VMDK  
1024 GB  
8 MB  
2048 GB  
To configure the data disk:  
1. In the VI Client, navigate to the Inventory Panel.  
2. Click Add at the bottom of the Hardware tab.  
3. Select Hard Disk as the type of device to add and click Next.  
4. Select Create a new virtual disk and click Next.  
5. In the Disk Capacity section, designate a capacity that is suitable for the amount of storage  
available on your ESX Server.  
6. In the Location section, select Store with Virtual Machine, and click Next.  
7. For the first disk, select the Virtual Device Node to be SCSI1:0 from the list. For additional  
disks, assign SCSI 1:1 through 1:4, in sequential order.  
CAUTION: Selecting anything other than SCSI 1:0 for the first disk causes RAID to be  
unconfigurable later.  
8. Select ModeIndependentPersistent and click Next.  
9. Review the device configuration and click Finish.  
Powering on the VSA for vSphere and setting IP address and hostname  
1. In the inventory panel, select the new VSA for vSphere and power it on.  
2. Select the Console tab and wait for the VSA for vSphere to boot.  
3. When the VSA for vSphere finishes booting, enter Start and press Enter to log in to the  
Configuration Interface.  
4. On the Configuration Interface main menu, press Tab to select Network TCP/IP Settings and  
press Enter.  
5. On the Available Network Devices window, press Tab to select the applicable network interface  
and press Enter.  
6. On the Network Settings window, press Tab to select the Hostname box and enter a host  
name for the VSA. Use backspace to erase an entry if necessary.  
This host name displays in the CMC only. It does not change the name of the original .vmx  
file or the name of the virtual machine in the VMware interface.  
7. Press Tab to select the method for setting the IP address.  
If you are entering a static IP address, note that Gateway is a required field. If you do not  
have a gateway, enter 0.0.0.0.  
8. Press Tab to select OK and press Enter.  
9. Press Enter again to confirm the action.  
10. After the settings are configured, press Enter to confirm the IP address change.  
11. On the Available Network Devices window, press Tab to select Back and press Enter.  
12. On the Configuration Interface, press Tab to select Log Out and press Enter.  
Finishing up with VI Client  
1. In the VI Client Information Panel, select the Summary tab.  
2. In the General section on the Summary tab, verify that the IP address and host name are  
correct, and that VMware Tools are running.  
Powering on the VSA for vSphere and setting IP address and hostname  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
NOTE: If VMware Tools show out of dateor Unmanaged, then they are running correctly.  
These statuses are not a problem, because the tools are available and running. VMware tools  
are updated with each LeftHand OS software upgrade.  
3. Optional: If you want the name of the VSA for vSphere to match the host name in the CMC,  
in the inventory panel, right-click the VSA for vSphere and select Rename and enter the host  
name.  
10  
Installing the HP StoreVirtual VSA for VMware vSphere  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 Installing the HP StoreVirtual VSA for Microsoft Hyper-V  
The HP StoreVirtual VSA for Microsoft Hyper-V is pre-formatted for use with Microsoft® Windows®  
Server Hyper-V™. Install the VSA for Hyper-V on a Windows server configured with redundant  
RAID. If you are using an evaluation copy and want to continue using the VSA for Hyper-V after  
the trial period has ended, you must purchase a license key. After you apply the license key, your  
configuration can be used as is in a production environment, or reconfigured if necessary.  
Supported versions of Microsoft Windows Server  
All operating systems listed are 64–bit. HP StoreVirtual VSA for Microsoft Hyper-V is supported on  
64–bit systems only.  
Windows Server 2012  
Microsoft Hyper-V Server 2008 R2  
Windows Server 2008 R2 Standard  
Windows Server 2008 R2 Enterprise  
Windows Server 2008 R2 Datacenter  
Windows Server 2008 R2 Server Core  
Windows Server 2008 SP2, except for Core, which is not supported  
Prerequisites  
Available drive space of up to 10 TB for Hyper-V Server. HP recommends installing Hyper-V  
Server on top of a redundant RAID configuration. Do not use RAID 0.  
Applicable memory reserved based on total disk capacity (Table 4 (page 11)).  
Table 4 Memory requirements for VSA for Hyper-V disks  
Total capacity of all installed disks  
5 GB to 500 GB  
Requires at least this much memory  
3 GB  
4 GB  
5 GB  
500 GB to 5 TB  
5 TB to 10 TB  
A Gigabit Ethernet or internal network environment, including the following:  
A host name for the VSA for Hyper-V.  
A network configuration plan, including reserved IP addresses, subnet mask, and gateway  
for the VSA for Hyper-V, or use DHCP (requires statically assigned IP addresses).  
Two virtual CPUs with at least 2000 MHz reserved.  
Define the install paths for the Hyper-V virtual machine and the virtual hard disks.  
Ensure the following hotfixes are applied before beginning the installation: KB 979711, KB  
975530, KB 981836.  
If using physical disks for the VSA for Hyper-V:  
Ensure that the disks are completely clean of any partitions or any other remnants prior  
to running the VSA for Hyper-V installer  
Ensure that the disks are connected, but offline in Windows Disk Manager before starting  
the installer  
Supported versions of Microsoft Windows Server  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Best practices  
HP recommends installing Hyper-V Server on top of a redundant RAID configuration with a RAID  
controller that has battery-backed cache enabled. Do not use RAID 0.  
Unsupported configurations  
Running VSA for Hyper-Vs on top of existing HP StoreVirtual Storage is not recommended.  
The hot adding or removal of virtual hard disks and pass-through disks is not supported. See  
the Microsoft Linux Integration Services User Guide.  
In a VSA for Hyper-V configuration, only disk 1 can be used if you are using physical disk  
pass-thru on any Dell server. However, multiple VHDs can be used.  
For additional information about unsupported configurations and best practices, see the HP  
StoreVirtual Storage User Guide.  
Installing the HP StoreVirtual VSA for Microsoft Hyper-V  
Install the HP StoreVirtual VSA for Microsoft Hyper-V using any of the following methods:  
Download the HP StoreVirtual VSA for Microsoft Hyper-V from either of these HP websites:  
or  
Install the HP StoreVirtual VSA for Microsoft Hyper-V from the HP StoreVirtual VSA and Failover  
Manager DVD.  
The installer for the VSA for Hyper-V includes a wizard that guides you through configuring the  
virtual machine on the network, configuring virtual or physical hard drives, and powering on the  
VSA for Hyper-V. After finishing the installation, install the CMC and find the VSA for Hyper-Vs as  
storage systems in the CMC. You can then set up the clustered storage for the SAN, as described  
NOTE: One or more Microsoft hotfixes may be required on your system before you can install  
the VSA for Hyper-V. If this is the case, before the installer actually begins, a window opens that  
notifies you of the required hotfixes and provides links to the appropriate site to download the  
hotfix.  
Table 5 Configuring the VSA for Hyper-V using the installer wizard  
Installer Step  
Hotfix required  
Type  
Definition  
Lists one or more Microsoft hotfixes that must be installed before installing the VSA for Hyper-V.  
VSA for Hyper-V Server is the storage system  
Destination  
Network  
Locations for the virtual machine and the virtual disks.  
Includes the following network information:  
Host name for the VSA for Hyper-V.  
IP address.  
Reserved IP address is recommended. DHCP is available (requires statically assigned IP  
addresses).  
The network interface designated for the virtual machines. The VSA for Hyper-V can support  
up to two NICs.  
12  
Installing the HP StoreVirtual VSA for Microsoft Hyper-V  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Table 5 Configuring the VSA for Hyper-V using the installer wizard (continued)  
Installer Step  
Definition  
Virtual machine  
Information for creating the virtual machine, including the following:  
Name for the virtual machine in Hyper-V  
Type of hard drives, virtual or physical  
Check box to power on the VSA for Hyper-V after it is installed  
Hard drives, either One of two windows opens, depending on which type of drives were selected in the Virtual  
virtual or physical machine window.  
Virtual or physical drive requirements  
Maximum of 5 drives  
Minimum size: 5 GB  
Maximum size: 2040 GB  
Virtual hard drives window  
Select up to 5 virtual hard drives and designate the size.  
Physical Drives window  
Select up to five physical drives that you have prepared, and which are offline. These drives must  
have no partitions or volumes on them, or the installer will not list them.  
IMPORTANT: Total amount of configured storage on the VSA for Hyper-V cannot exceed 10 TB  
or virtual RAID will fail.  
1. Begin the installer one of the following ways:  
Unzip the files if you downloaded a .zip file, and then double-click the executable to start  
the installation.  
Double-click the downloaded executable to start the installation.  
Insert the DVD in the DVD drive (either the physical HP StoreVirtual VSA and Failover  
Manager DVD you received or the DVD you created after downloading the DVD .iso  
image from the web).  
2. Accept the terms of the License Agreement.  
3. Configure the parameters of the virtual machine on the network, including the hard drives.  
NOTE: You can run the wizard again to configure another VSA for Hyper-V using the same  
parameters as appropriate.  
4. Finish the installation, reviewing the configuration summary.  
When the installer is finished, the VSA for Hyper-V is ready to be used in HP StoreVirtual  
Storage.  
5. Next, install the CMC, described in “Getting started with HP StoreVirtual Storage” (page 14).  
Then follow the steps in “Installing the CMC” (page 14).  
The installer may take a few minutes to complete, depending upon the underlying hardware.  
Troubleshooting  
Table 6 Troubleshooting the VSA for Hyper-V installation  
Problem  
Solution  
While installing the VSA for Hyper-V, you do not see the  
physical disks you prepared.  
1. Close the installer.  
2. Verify that the disks are offline.  
3. Start the installer again.  
Troubleshooting  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 Getting started with HP StoreVirtual Storage  
Installing the CMC  
Install the CMC on the computer or virtual machine that you use to administer the HP StoreVirtual  
Storage. You administer the entire network of VSAs from this CMC. To obtain the CMC, download  
the CMC installer from the following website:  
Prerequisite  
For the CMC installation, 63 MB disk space and 64 MB RAM during runtime.  
Installing the CMC in Microsoft Windows  
1. Start the CMC installer.  
2. Follow the steps in the installation wizard.  
3. When the installation completes, HP is added as a separate Program Group and a shortcut  
icon is added to the Microsoft Windows desktop.  
To start the CMC:  
Double-click the icon on your desktop, or  
From the Start menu, select All ProgramsHP HP StoreVirtualHP StoreVirtual Centralized  
Management Console.  
Installing the CMC in Linux  
You must be running the X Window System to install the application.  
1. Click the CMC installer.  
2. Follow the steps in the installation wizard.  
3. When the installation completes, HP is added as a separate Program Group.  
To start the CMC:  
From the directory into which you installed the files, run the script ./Console.  
Getting started with the CMC  
The CMC is configured to find all systems on the subnet on which it is installed. The first time you  
open the CMC, it automatically finds all the storage systems and they appear in the Navigation  
pane.  
To control which systems appear in the CMC, change the configuration using the following steps.  
1. Open the CMC.  
14  
Getting started with HP StoreVirtual Storage  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
2. Click Find Systems on the Getting Started Launch Pad.  
In the Find Systems window, use these features to control the list of systems:  
Clear Auto Discover by Broadcast to prevent the entire subnet of systems from appearing  
in the navigation pane.  
Add individual IP addresses of systems that you want to appear in the navigation pane.  
Figure 1 Editing Find Systems to control the systems displayed  
1. Clear Auto Discover by Broadcast  
2. Add IP addresses for specific systems  
Verify the hardware configuration  
Ensure the hardware configuration is correct before adding the VSA to a management group.  
Select the VSA in the navigation window to expand the hardware configuration categories. Verify  
that virtual RAID is configured. Verify that the Network settings are correct.  
Getting started with the CMC  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Virtual NICs  
Figure 2 Configuring the hardware  
1. Configure RAID and the network from these categories  
Configuring RAID  
Configure RAID after powering on the VSA. If you power off the VSA and add disks, you must  
re-configure RAID when you power on the VSA.  
RAID and the VSA for Hyper-V Server  
If you create the VSA for Hyper-V Server with one disk, RAID will be automatically configured. If  
you create the VSA for Hyper-V Server with more than one disk, you must manually add the  
remaining disks to RAID using the CMC.  
1. Select the system in the Available Systems pool.  
2. Navigate to the Storage category.  
3. Use either of the following methods to add the remaining disks to RAID.  
On the RAID Setup tab, click RAID Setup Tasks and select Reconfigure RAID.  
On the Disk Setup tab, click Disk Setup Tasks and select Add Disks to RAID.  
16  
Getting started with HP StoreVirtual Storage  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 3 Adding additional disks to RAID in the VSA for Hyper-V Server  
RAID and the VSA for vSphere Server  
If you have trouble configuring RAID now, you may have made a mistake when configuring a  
virtual disk earlier. On the ESX Server, verify that the VSA has at least one virtual disk. The first  
virtual disk must be configured on SCSI 1:0. Additional disks must be configured sequentially on  
SCSI 1:1 through 1:4. VSAs use SCSI 0:0 and 0:1 for operating system disks, and use the disk  
configured for SCSI 1:0 for SAN data storage. If no SCSI disk is configured for SCSI 1:0, RAID  
cannot be configured on the appliance.  
NOTE: If you want to clone the VSA for vSphere Server, do it now. You must only clone a VSA  
while it is in the Available Systems pool.  
Creating the iSCSI SAN  
Use the Management Groups, Clusters, and Volumes wizard to create your storage pool. For  
information about using the wizards, see the HP StoreVirtual Storage User Guide or the HP  
StoreVirtual Storage Online Help.  
Best Practice Summary  
Use the Best Practice Summary on the SAN Status Page in the CMC to review your SAN  
configuration and to ensure you are following best practices for the disk RAID and Network RAID  
configurations, as well as network configurations and the overall SAN configuration. The Best  
Practice Summary provides an easy-to-use reference about best practices that can increase the  
reliability and performance of your SAN configurations. Move the mouse over a best practice item  
to see an explanation of the best practice.  
1. Navigate to the SAN Status Page in the CMC.  
2. Log in to the management group to verify the Best Practices for that management group.  
Creating the iSCSI SAN  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Troubleshooting  
Table 7 Troubleshooting installation—HP StoreVirtual VSA for VMware vSphere  
Problem  
Solution  
You want to reinstall the VSA  
1. Close your CMC session.  
2. In the VI Client, power off the VSA.  
3. Right-click and select Delete from Disk.  
4. Copy fresh files into the virtual machine folder from the  
downloaded .zip file or distribution media.  
5. Open VMware and begin again.  
You cannot find the VSA with the CMC, and cannot recall Open the Configuration Interface. Navigate to the Network  
its IP address.  
Settings window to verify the IP address.  
You cannot configure RAID.  
Verify that the VSA has a virtual disk configured on SCSI  
1:0. VSAs use SCSI 0:0 and 0:1 for operating system  
disks. They use the disk configured for SCSI 1:0 for SAN  
data storage. If no SCSI disk is configured for SCSI 1:0  
then RAID cannot be configured on the appliance.  
In Windows  
If the Installation wizard freezes, reset the Hardware  
Acceleration in Windows.  
1. Open the Windows Display SettingsAdvanced  
settingsTroubleshoot tab.  
2. Move the Hardware Acceleration slider to one notch  
above None.  
3. Click OK, and then OK again to leave the Properties  
dialog.  
4. Restart the Installation wizard.  
In Linux  
If the installer does not start automatically  
In VI Client  
Run CMC_Installer.bin again.  
You do not have the cursor or the keyboard available.  
If your cursor is missing, you are in console mode. Press  
Ctrl-Alt to regain the cursor. If your keyboard is missing,  
move the mouse to the console window and click once.  
You want to see your VSA, but the window is black.  
You are in the console view of the guest window.  
Change to the Summary view.  
Your console window has timed out. Click in the window  
with the mouse and then press Backspace.  
Table 8 Troubleshooting installation—HP StoreVirtual VSA for Microsoft Hyper-V  
Problem  
Solution  
You want to reinstall the VSA  
Using the Hyper-V Manager:  
1. Close your CMC session.  
2. In the Hyper-V Manager, power off the VSA.  
3. Right-click and select Delete from Disk.  
4. Optional: Delete the .vhdfiles to recover the disk  
space.  
5. Rerun the .exefile and reinstall the VSA.  
6. Open the Hyper-V Manager and begin again.  
You cannot find the VSA with the CMC, and cannot recall Open the Configuration Interface. Navigate to the Network  
its IP address.  
Settings window to verify the IP address.  
18  
Getting started with HP StoreVirtual Storage  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Documentation available  
For detailed instructions about using the CMC and the VSA, see the following resources. You can  
find these documents on the HP StoreVirtual Management Software DVD and on the Manuals page  
of the HP Business Support Center website:  
HP StoreVirtual Storage Online Help  
All User Guide content is contained in the HP StoreVirtual Storage Online Help, available  
from the menu bar under HelpHelp Topics. Context sensitive help is available by clicking  
the question mark on any window ( ).  
HP StoreVirtual Storage User Guide  
The HP StoreVirtual Storage User Guide provides detailed instructions for using the LeftHand  
OS software to create, access and manage the clustered data storage.  
HP StoreVirtual Storage Remote Copy User Guide  
The HP StoreVirtual Storage Remote Copy User Guide provides instructions for using the  
Remote Copy capabilities of the LeftHand OS software.  
HP StoreVirtual Storage Multi-Site Configuration Guide  
The HP StoreVirtual Storage Multi-Site Configuration Guide provides instructions for configuring  
and using the HP StoreVirtual Multi-Site SAN.  
Documentation available  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 Designing a virtual SAN  
The VSA enables full featured use of the LeftHand OS software in a virtualized environment. When  
deployed correctly, HP LeftHand SANs are scalable, highly available, and fully redundant.  
Figure 4 Example of a virtual SAN using the VSA  
Designing your virtual SAN  
The design of your virtual SAN affects both its performance and its reliability for production use.  
Use the concepts and practices in this manual when installing and managing your virtual SAN to  
ensure optimal performance and reliability.  
Configuration requirements  
The following configuration requirements are prerequisites for HP to support your virtual SAN for  
production use.  
A qualified server running VMware ESX Server. Qualified servers are listed in VMware ESX  
Server systems compatibility guide, which can be found at  
A qualified server running Microsoft Hyper-V Server. To verify the server is listed and qualified  
cpID=0&avc=11&ava=0&OR=1&PGS=25, and then search for “Hyper-V” as an additional  
qualification. See supported Windows versions.  
Reserved memory based on total disk capacity, as listed in Table 9 (page 20).  
Table 9 Memory requirements for VSA disks  
Total capacity of all installed disks  
5 GB to 500 GB  
Requires at least this much memory  
3 GB  
4 GB  
5 GB  
500 GB to 5 TB  
5 TB to 10 TB  
Two virtual CPUs with at least 2000 MHz reserved.  
NOTE: The Hyper-V installer assigns 1000 MHz by default.  
A connection to a virtual switch or virtual network with at least a Gigabit network connection.  
Virtual disk(s) with 5 GB to 2 TB (2047 GB for ESX, 2040 GB for Hyper-V Server virtual  
machines) of space per disk located on internal disk storage, or direct attached storage that  
20 Designing a virtual SAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
is not accessible from more than one physical server. (Note that the LeftHand OS software  
consumes a small amount of the available space.)  
For ESX Server, the first virtual disk must be connected to SCSI address 1:0.  
For Hyper-V Server, the first virtual disk must be connected to the first SCSI Controller.  
All virtual disks for the VSA for vSphere must be configured as independent and persistent to  
prevent VM snapshots from affecting them.  
Virtual disks for VSA for Hyper-V must be fixed, not dynamic.  
The VMFS datastore or NTFS partition for the VSA must not be shared with any other VMs.  
Two or more VSAs on separate physical servers with Network RAID-10, and a Failover  
Manager is the minimum configuration for high availability with automatic failover.  
Two or more VSAs on separate physical servers can be clustered with a Virtual Manager for  
manual failover.  
Best practices  
Other configuration recommendations are useful to improve the reliability and performance of your  
virtual SAN. Consider implementing as many of these best practices as possible in your virtual  
SAN environment.  
Each VSA should meet the following conditions, if possible.  
Have a virtual switch or virtual network comprised of dual Gigabit Ethernet or more. Providing  
network redundancy and greater bandwidth improves both performance and reliability.  
Be configured to start automatically and first, and before any other virtual machines, when  
the ESX Server on which it resides is started. This ensures that the VSA is brought back online  
as soon as possible to automatically re-join its cluster. The default installation configuration  
for the VSA for Hyper-V is set to automatically start if it was running when the server shut  
down.  
Use redundant RAID for the underlying storage of a VSA in each server to prevent single disk  
failures from causing VSA system failure. Do not use RAID 0.  
NOTE: See the HP StoreVirtual Storage User Guide for detailed information about using  
RAID for individual server-level data protection.  
For the VSA for Hyper-V, dedicate a unique network adapter for iSCSI traffic.  
For the VSA for vSphere, be located on the same virtual switch as the VMkernel network used  
for iSCSI traffic. This allows for a portion of iSCSI IO to be served directly from the VSA to  
the iSCSI initiator without using a physical network.  
For the VSA for vSphere, be on a virtual switch that is separate from the VMkernel network  
used for VMotion. This prevents VMotion traffic and VSA IO traffic from interfering with each  
other and affecting performance.  
Unsupported configurations  
NIC bonding between the 2 virtual NICs in the VSA is not supported. (NIC bonding is a best  
practice in the server.)  
The virtual NICs on the VSA for vSphere and VSA for Hyper-V do not support flow control  
setting modifications or TCP off-load. The physical NICs on the server can be configured with  
these features.  
Use of VMware snapshots, VMotion, HA, DRS, or Microsoft Live Migration on the VSA itself.  
Use of any ESX Server configuration that VMware does not support.  
Designing your virtual SAN  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Use of any Hyper-V Server configuration that Microsoft does not support.  
Booting physical servers off of a VSA cluster.  
Extending the data virtual disk(s) (ESX Server SCSI 1:x or in Hyper-V, the first SCSI Controller)  
of the VSA while in a cluster.  
Co-location of a VSA and other virtual machines on the same physical platform without  
reservations for the VSA CPUs and memory in ESX.  
Co-location of a VSA and other virtual machines on the same VMFS datastore or NTFS partition.  
Hardware design for VSA  
The hardware platform used for a virtual SAN affects the capacity, performance, and reliability  
of that virtual SAN. The hardware features listed below affect the VSA configuration.  
CPU  
Memory  
Virtual Switch or Network  
Controllers and Hard Disk Drives  
Network Adapters  
CPU  
Because the CPUs of the VSA must be reserved, platforms that will host a VSA and other VMs  
should be built with more processor cores to accommodate the additional VMs. Multi-core processors  
with at least 2 GHz per core should be used so that two cores with at least 2 GHz can be reserved  
for the VSA. All additional cores are then available for use with other VMs, thereby avoiding  
resource contention with the virtual SAN. For example, a platform with two dual core processors  
could host a VSA and use 3 cores to share for other VMs.  
Memory  
Similarly the memory of the VSA must be reserved. For platforms that will host a VSA and other  
VMs, build in additional memory to accommodate the additional VMs. All system memory on the  
host that is not used by the VSA can be used by other VMs  
Virtual switch or network  
The virtual switch or network should be entirely dedicated to the VSA and not used for any other  
traffic.  
Controllers and hard drives  
The internal disk controller and actual hard disk drives of a platform affect the capacity and IO  
performance of the VSA. Ideally VSAs should use storage that is hosted by many SAS or SCSI  
drives. If you are designing a new server that will host VSAs, you should incorporate the following  
recommendations.  
Use as many hard drives as the platform will allow and prefer faster rotation speeds. The more  
hard drives and the faster their rotation speed, the more IOPs, and better performance.  
Select controllers with protected write cache and ensure that the write cache is enabled.  
Do not enable disk caching on servers that host VSAs.  
Network adapters  
The number of network adapters available in a platform affects your options for configuring virtual  
switches. VSAs that will have a dedicated server platform only need two ethernet (minimum 1 GB)  
22 Designing a virtual SAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
network adapters. Platforms that will host VSAs and other virtual machines should have four ethernet  
(minimum 1 GB) network adapters so that two adapters can be dedicated to the VSA and iSCSI  
traffic.  
Virtual network design  
The virtual switch or virtual network that is used for VSA should be at least a redundant Gigabit  
network, if possible. Performance and reliability can be improved even further by using more than  
two ethernet adapters in the iSCSI and VSA virtual networks or by using 10 GB for increased  
performance.  
Using VSAs with HP StoreVirtual Storage  
VSAs and physical platforms can be mixed in management groups. When mixing virtual and  
physical platforms, and mixing differently configured VSAs, you should take the following  
requirements and guidelines into consideration.  
Cloning VSAs  
To clone a VSA, you must do so while the VSA is still in the Available Systems pool, before  
you add it to a management group. Cloning a VSA after it is in a management group is not  
supported.  
NOTE: Configure the first VSA for RAID and Networking. Then create your clone with the  
hardware settings already configured.  
Running managers on physical platforms  
When possible, locate all managers in a management group on physical platforms instead  
of VSAs, and ideally on the fastest platforms in the management group. While VSAs can run  
managers, physical platforms provide better performance and a lower likelihood that they  
will be rebooted for administrative reasons.  
Locating VSAs that are running managers on separate physical platforms  
If VSAs are running managers, ensure that those VSAs reside on separate physical platforms.  
Otherwise, rebooting a single physical platform could cause a loss of quorum in the  
management group.  
Managing the performance impact of mixing platforms in clusters  
Mixing VSAs built from different hardware in the same cluster also yields unpredictable  
performance. Typically the overall performance of the cluster is close to the aggregate average  
of the storage systems in the cluster.  
Additionally, you may perceive performance degradation if a faster VSA fails, thereby causing  
volumes to fail over to a slower VSA. Such performance degradation is normal in a mixed  
cluster.  
Managing the storage capacity of mixing platforms in clusters  
While clusters can contain storage systems with different capacities, all storage systems in a  
cluster operate at a capacity equal to that of the smallest-capacity storage system. The additional  
capacity on the VSA will operate according the same rules for physical storage systems in a  
cluster; that is, the VSA will operate at a capacity equal to that of the smallest capacity VSA  
in the cluster. See “Clusters and storage systems” in the HP StoreVirtual Storage User Guide  
for more information.  
Adding storage capacity to a VSA  
Add storage capacity to a VSA by adding up to 4 additional virtual disks for a total of 5 disks.  
Ensure that if you add capacity to a VSA in a cluster, you balance the capacity of all the storage  
Virtual network design 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
systems in the cluster. See “Using VSAs with HP StoreVirtual Storage” (page 23) for information  
about storage capacity and platforms in a cluster.  
The following steps describe how to add disks after the VSA has been added to a management  
group and cluster. However, you can add the disks to the VSA when you first configure it, before  
you use it for clustered storage.  
Create additional disks  
Create up to 4 additional disks for a VSA.  
Requirements  
Minimum disk size—5 GB  
Maximum disk size—2047 GB for ESX, 2040 GB for Hyper-V  
Created sequentially as follows:  
ESX Server—from SCSI 1:1 through SCSI 1:4. This assumes that the first disk has already  
been created and assigned to SCSI 1:0.  
Hyper-V—Add up to four additional disks to SCSI Controller 0, location 1 through 4. This  
assumes that the first disk has already been created in SCSI Controller 0, location 0.  
Creating the disk  
1. Power off the VSA.  
2. Using either VMware Server, VI Client, or Microsoft virtual machine manager, add from 1 to  
4 disks to the VSA.  
3. Assign each disk to the next sequential SCSI address or location.  
4. Configure the disks as follows:  
ESX Server disks as independent and persistent  
Hyper-V disks as fixed size  
5. Increase memory based on the total capacity of the VSA, according to the requirements in  
Table 10 Memory requirements for VSA disks  
Total capacity of all installed disks  
5 GB to 500 GB  
Requires at least this much memory  
3 GB  
4 GB  
5 GB  
500 GB to 5 TB  
5 TB to 10 TB  
6. Power on the VSA when you have finished adding disks.  
Adding disks to RAID  
A new disk appears as Uninitialized in the Disk Setup tab of the Storage configuration category.  
Add the new disk to RAID, which automatically powers the disk on.  
1. In the CMC, navigate to the VSA.  
2. Select the Storage configuration category and select the Disk Setup tab.  
3. Select the disk to add to RAID.  
Disks must be added to RAID sequentially. For example, you cannot add disk 3 to RAID if disk  
2 has not been added.  
4. Right-click and select Add Disk to RAID.  
24 Designing a virtual SAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Sample configurations  
Some sample configurations and their uses and benefits are described below.  
Single system configuration  
A single system configuration is useful for implementing a simple iSCSI target that can scale up to  
a redundant iSCSI SAN of any size. A single system configuration has only the elements listed  
IMPORTANT: A single system configuration offers no data protection, failover, or redundancy,  
and is not recommended.  
One VSA  
A single management group  
A single cluster  
Running a single manager  
Figure 5 Single system configuration  
Two-system configuration  
A two-system configuration is the smallest possible redundant configuration. Automatic failover  
between systems requires a failover manager. A two-system configuration includes the elements  
listed.  
Two VSAs in a single management group  
A single cluster  
Two managers  
A Failover Manager added to the management group  
NOTE: For more information, see “Failover Manager Overview” in the HP StoreVirtual  
Storage User Guide, available on the Manuals page of the HP Business Support Center  
website:  
Sample configurations 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Figure 6 Two-system configuration  
Three-system-plus configuration  
All configurations greater than two systems can be redundant, and do not require a Virtual Manager  
or Failover Manager. A configuration greater than two systems includes the items listed.  
Three or more systems in a management group  
Multiple clusters with as many VSAs as desired in each cluster  
Running three or five managers, as appropriate  
Figure 7 Three-system-plus configuration  
26 Designing a virtual SAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6 Using the VMware VSA laptop demo  
The VMware VSA laptop demo is the smallest and most portable version of the LeftHand OS  
software virtual appliance. Use this demo to create HP StoreVirtual Storage, complete with storage  
clusters.  
NOTE: There is not a separate demo version of the HP StoreVirtual VSA for Microsoft Hyper-V  
Server.  
The VSA can be used for free indefinitely as a single system iSCSI target with snapshots. If a  
configuration is deleted and recreated, the trial period of licensed features starts again.  
To use the VSA fully featured on an ESX Server, purchase a license and follow the instructions in  
Storage.  
The VSA runs a full-featured version of the LeftHand OS software, and provides the following  
capabilities:  
Use of the LeftHand OS software without requiring physical storage devices.  
Use of advanced LeftHand OS software features such as Clustering and Virtualization, Managed  
Snapshots, Remote Copy and Multi-Site SAN during an evaluation period.  
The demo is available at www.hp.com/go/tryvsa.  
Requirements for the demo  
The demo VSA is supported on 64–bit systems only  
Minimum of 3 GB of RAM  
One virtual CPU with 2GHz reserved  
A dedicated gigabit virtual switch  
5 GB to 2 TB of disk space per virtual disk, up to 10 TB total per virtual storage appliance  
VMware Player, Workstation, or Server  
IP address, subnet mask, and gateway for the virtual machine  
Planning the demo installation  
Before you install the VSA, plan the virtual network configuration. Then, when you install the CMC,  
plan and configure the hardware features before configuring the virtual storage system for data  
storage.  
Virtual appliance directories, host names and IP addresses. Create a directory for each virtual  
machine on the hard drive you will use as the storage system.  
Network configuration. Plan the subnet and IP address for the virtual machines as well as for  
the VIPs required for storage clusters.  
Storage configuration. Install the CMC on a Linux or Microsoft Windows OS. Then use the  
CMC to find storage systems, create storage, and connect to application servers.  
Installing the VSA  
When you start the VSA for the first time with a VMware console, you will:  
Unzip to the prepared directory and start the virtual machine.  
Direct the Ethernet port to NAT (default), Host-only, or bridged.  
Set the IP address and host name of the VSA.  
Requirements for the demo 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
You only need to configure each virtual machine once.  
1. Copy or download the VSA .zip file.  
2. Copy or unzip the VSA files to the virtual machine directory.  
Copy the files to multiple directories for multiple VSAs.  
Configuring the VSA with VMware Player, VMware Server, or VMware Workstation  
1. Open the VMware console.  
2. Click FileOpen to open the VSA.vmxfile.  
3. Navigate to the location of the unzipped VSA files.  
4. Select the VSA.vmxfile and click Open.  
5. Edit the VSA settings as required by the VMware console you are using. Select the appropriate  
network mode:  
Bridged  
NAT  
Host-only  
NOTE: All VSAs on the same platform should use the same networking mode. When running  
multiple VSAs on a single host, use NAT or Host-only networking mode, and use DHCP to  
assign IP addresses to the VSAs.  
6. Power on the VSA.  
7. Use the Configuration Interface to set the IP address and host name as described in “Powering  
28 Using the VMware VSA laptop demo  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7 Support and other resources  
Contacting HP  
For worldwide technical support information, see the HP support website:  
Before contacting HP, collect the following information:  
Product model names and numbers  
Technical support registration number (if applicable)  
Product serial numbers  
Error messages  
Operating system type and revision level  
Detailed questions  
Subscription service  
HP recommends that you register your product at the Subscriber's Choice for Business website:  
After registering, you will receive e-mail notification of product enhancements, new driver versions,  
firmware updates, and other product resources.  
Rack stability  
Rack stability protects personnel and equipment.  
WARNING! To reduce the risk of personal injury or damage to equipment:  
Extend leveling jacks to the floor.  
Ensure that the full weight of the rack rests on the leveling jacks.  
Install stabilizing feet on the rack.  
In multiple-rack installations, fasten racks together securely.  
Extend only one rack component at a time. Racks can become unstable if more than one  
component is extended.  
Customer self repair  
HP customer self repair (CSR) programs allow you to repair your HP product. If a CSR part needs  
replacing, HP ships the part directly to you so that you can install it at your convenience. Some  
parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair  
can be accomplished by CSR.  
For more information about CSR, contact your local service provider, or see the CSR website:  
HP Insight Remote Support Software  
HP strongly recommends that you install HP Insight Remote Support software to complete the  
installation or upgrade of your product and to enable enhanced delivery of your HP Warranty,  
HP Care Pack Service or HP contractual support agreement. HP Insight Remote Support supplements  
your monitoring, 24x7 to ensure maximum system availability by providing intelligent event  
diagnosis, and automatic, secure submission of hardware event notifications to HP, which will  
Contacting HP 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
initiate a fast and accurate resolution, based on your product’s service level. Notifications may be  
sent to your authorized HP Channel Partner for on-site service, if configured and available in your  
country. The software is available in two variants:  
HP Insight Remote Support Standard: This software supports server and storage devices and  
is optimized for environments with 1-50 servers. Ideal for customers who can benefit from  
proactive notification, but do not need proactive service delivery and integration with a  
management platform.  
HP Insight Remote Support Advanced: This software provides comprehensive remote monitoring  
and proactive service support for nearly all HP servers, storage, network, and SAN  
environments, plus selected non-HP servers that have a support obligation with HP. It is  
integrated with HP Systems Insight Manager. A dedicated server is recommended to host both  
HP Systems Insight Manager and HP Insight Remote Support Advanced.  
Details for both versions are available at: http://www.hp.com/go/insightremotesupport  
To download the software, go to Software Depot:  
Select Insight Remote Support from the menu on the right.  
Related information  
You can find related documents on the product manuals page  
HP websites  
For additional information, see the following HP websites:  
30 Support and other resources  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
8 Documentation feedback  
HP is committed to providing documentation that meets your needs. To help us improve the  
documentation, send any errors, suggestions, or comments to Documentation Feedback  
([email protected]). Include the document title and part number, version number, or the URL  
when submitting your feedback.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Graco Baby Playpen PD243008A User Manual
Graco Crib PD243238A User Manual
Grundig Flat Panel Television 46 VLE 8160 WL User Manual
Grundig TV DVD Combo GULCD15S DVD User Manual
Haier Air Conditioner HSU 18LEK03 R2DB User Manual
Hans Grohe Plumbing Product 31263XX1 User Manual
Hasbro Games 06102 User Manual
Hotpoint Microwave Oven DE47 User Manual
HP Hewlett Packard DVD Recorder DVD100I User Manual
Hunter Fan Outdoor Ceiling Fan 42443 01 User Manual