Service and
User Manual
Hewlett-Packard
SureStore E Hub
Models S10 and L10
Download from Www.Somanuals.com. All Manuals Search And Download.
Hewlett-Packard SureStore E Hub
Models S10 and L10
Service and User Manual
Edition E0899
Order No. A3724-90006
Printed in U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
Safety Instructions
© Hewlett-Packard Company, 1997, 1998, 1999.
All rights reserved.
Grounding
This product is a safety class I product and has a
protective earthing terminal. There must be an
uninterruptible safety earth ground from the main
power source to the product’s input wiring
terminals, power cord, or supplied power cord set.
Whenever it is likely that the protection has been
impaired, disconnect the power cord until the
ground has been restored.
Hewlett-Packard Company makes no warranty of
any kind with regard to this material, including, but
not limited to, the implied warranties of
merchantability and fitness for a particular purpose.
Hewlett-Packard shall not be liable for errors
contained herein or for incidental or consequential
damages in connection with the furnishing,
performance, or use of this material.
Service
This document contains proprietary information,
which is protected by copyright. No part of this
document may be photocopied, reproduced, or
translated into another language without the prior
written consent of Hewlett-Packard. The
information contained in this document is subject to
change without notice.
Any servicing, adjustment, maintenance, or repair
must be performed only by authorized service-
trained personnel.
Format Conventions
Denotes
Warranty
WARNING
Caution
Note
A hazard that can cause
personal injury
If you have any questions about the warranty for
this product, contact your dealer or local Hewlett-
Packard sales representative.
A hazard that can cause hardware
or software damage
Significant concepts or operating
instructions
Trademark Information
this font
Text to be typed verbatim: all
commands, path names, file
names, and directory names
HyperTerminal is a registered trademark of
Hilgreave, Inc.
this font
Text displayed on the screen
Windows and Windows NT are either a registered
trademark or trademark of Microsoft Corporation in
the United States and/or other countries.
<ENTER>
Keys to be pressed, for example,
the <ENTER> key
2
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1 Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Front Panel, Model S10 Short-Wave Hub. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Front Panel, Model L10 Long-Wave Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Rear Panel, Short-Wave and Long-Wave Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Supported Topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Single Short-Wave Hub Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Cascaded Short-Wave Hub Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Cascaded Long-Wave Hub Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Procedure 1: Prepare to Install the Hub. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Procedure 2: Unpack the Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Procedure 3: Verify Hub Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Procedure 4: Mount the Hub into a Rack (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . 27
Procedure 5: Plan the FC-AL Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Correct Cabling Example for a Short-Wave Hub . . . . . . . . . . . . . . . . . . . . . . . . . 32
Correct Cabling Example for a Long-Wave Hub . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Incorrect Cabling Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Nonsupported Cabling Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Procedure 6: Connect FC-AL Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Procedure 7: Verify the Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
3
Download from Www.Somanuals.com. All Manuals Search And Download.
For HP-UX servers: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
For HP NetServers: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
3 RS-232 Interface Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
About the RS-232 Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Tips for Using the RS-232 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Setting Up an RS-232 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Setting Up a Connection to a PC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Setting Up a Connection to a Dumb Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Updating the Hub Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Procedure 1: Obtain the Current Firmware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Procedure 2: Reboot the Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Procedure 3: Update the Hub Controller Firmware . . . . . . . . . . . . . . . . . . . . . . . 50
Procedure 4: Update the Hub Device Agent Code . . . . . . . . . . . . . . . . . . . . . . . . 52
Procedure 5: Reset the Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Procedure 6: Set Manufacturing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Enabling Hub Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Setting Hub IP Address and Network Configuration Options. . . . . . . . . . . . . . . 57
Verifying and Setting SNMP Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Configuring Cascaded Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Running Diagnostic Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Viewing Hub Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Troubleshooting Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
4
Download from Www.Somanuals.com. All Manuals Search And Download.
If the Power LED Is Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
If the Hub Fault LED Stays on After Self-Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
If a Fan Is Not Operating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
If a Device Is Unlisted/UNCLAIMED in ioscan or
Not Displayed in SCSI Adapters Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
If a Port LED Is Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
If a Port LED Is On When It Should Be Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
If the Management Server Cannot Ping the Hub. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
If Firmware Upgrade Appears to Fail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Recovering from Failed Firmware Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
5 Maintenance and Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
Replacing the Fan Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
6 Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Standard Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Operating Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Software and Operating System Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . 100
Physical and Cabling Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Supported Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Supported Distances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Physical Characteristics of Standalone Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Reference Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Laser Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
6
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURES
1 Front Panel Display, Short-Wave Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Front Panel Display, Long-Wave Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4 Example Topology: 10 Ports Shared among Server and FC-AL Devices . . . . . . . . . . . . . 17
5 Example Topology: Cascaded Short-Wave Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Example Topology: Cascaded Long-Wave Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7 Standalone Product Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8 Replacing Mounting Ear Brackets and Nylon Retainers . . . . . . . . . . . . . . . . . . . . . . . . . . 27
9 Installing Rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10 Installing the Hub into the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
11 Installing the Plenum Shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
12 Hub Correctly Installed in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
13 Cascaded Short-Wave Hub Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
14 Cascaded Long-Wave Hub Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
15 Incorrect Cabling Example: Connected Ports on the Same Hub . . . . . . . . . . . . . . . . . . .35
16 Incorrect Cabling Example: Disconnected Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
17 Incorrect Cabling Example: More Than One Cable Connection Between Hubs . . . . . . 36
18 Incorrect Cabling Example: Long-Wave Port Connections to Wrong Device/Port . . . . 36
19 Nonsupported Cabling Example: More Than Two Hubs Connected . . . . . . . . . . . . . . . 37
20 Nonsupported Cabling Example: HP-UX Server and HP NetServer
Connected to Same Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
21 Removing the Fan Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
22 Replacing the Fan Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
7
Download from Www.Somanuals.com. All Manuals Search And Download.
23 HP SureStore E Hub, Standalone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
24 HP SureStore E Hub, Factory-Racked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
25 Model S10 or L10 Option 001 Hub Rackmount Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
26 HP SureStore E Hub Replaceable Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
8
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLES
1 Worksheet for Hub Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
2 LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
3 HP SureStore E Hub Product Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
4 HP SureStoreE Hub Configuration Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
5 HP SureStore E Hub Replaceable Parts and Service Part Numbers . . . . . . . . . . . . . . . .98
6 Multimode Fiber Optic Cable Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
7 Power Cord Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8 Cable Plant Specifications: Single-Mode (2 km–10 km, 100 MB/sec) . . . . . . . . . . . . . . . 101
9 Cable Plant Specifications: 50-Micron Multimode (500 m, 100 MB/sec)
Non-OFC Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
10 Cable Plant Specifications: 62.5-Micron Multimode (175 m, 100 MB/sec)
Non-OFC Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
11 Supported Cable Distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
12 Environmental Specifications for Model S10 Short-Wave and
Model L10 Long-Wave Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
13 Physical Characteristics of Model S10 Short-Wave and Model L10 Long-Wave Hubs . 108
9
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
1
PRODUCT DESCRIPTION
Overview
Features
Front Panel, Model S10 Short-Wave Hub
Front Panel, Model L10 Long-Wave Hub
Rear Panel, Short-Wave and Long-Wave Hubs
Supported Topologies
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
The Hewlett-Packard SureStore E hub, short-wave model S10 and long-wave model L10, is
a full-duplex, 1063-megabit-per-second hub. It increases loop reliability, number of loop
connections, and distances between server and mass storage devices in a Fibre Channel
Arbitrated Loop. The hub’s port detection and bypass circuitry dynamically detects and
bypasses a failed node on the loop. Nodes can be added, removed, and reconnected
without bringing down the loop and disrupting communication for other nodes.
Fibre Channel Manager is a web-based software application that allows you to remotely
manage and monitor the health of the hub. To learn more about Fibre Channel Manager,
visit the Hewlett-Packard (Software Depot (http://www.software.hp.com). Fibre Channel
Manager is available as a free download from this web site.
Older hubs may require a firmware upgrade to meet Fibre Channel Manager’s minimum
requirements. The Software Depot web site has more information about this. The latest
hub firmware and upgrade instructions are available as a free download from this web site.
Detailed configuration information and part numbers for the hub are provided in chapter 6,
Reference.
12
Overview
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
HP SureStore E hubs provide the following features:
•
•
•
•
Short-wave hub (model S10): 10 non-Open Fibre Control (non-OFC) short-wave
optical transceivers
Long-wave hub (model L10): nine non-OFC, short-wave optical transceivers and one
non-OFC, long-wave optical transceiver
Local retime and regeneration of transmit signals to prevent accumulation of jitter and
improve the signal
Reliable, automatic bypass of failed nodes; dynamic recognition of newly added or
removed nodes, with a controller in each port permitting the bypass of a port if the port
fails signal validity tests
•
•
Active loop reconfiguration when a node to an arbitrated loop is added, removed, or
moved
Plug-and-play capability, which allows the hub to connect to compatible servers and
other Fibre Channel Arbitrated Loop (FC-AL) devices while they are operating ( FC-AL
devices can be added or removed while the hub is active.)
•
Cascade support (hub-to-hub connections) for increased loop distances
Cascaded short-wave hubs are supported up to 500 meters; cascaded long-wave hubs
are supported up to 3000 meters (3 km). Under certain conditions, cascaded long-wave
hubs are supported up to 10,000 meters (10 km) (see page 105 for more information).
The 10-km capability only applies to long-wave hubs connected to HP-UX servers.
Note
Increased loop distances are associated with increased latency times.
•
•
Access to the RS-232 interface for firmware upgrades and hub configuration and
troubleshooting
Support for a hub management tool (Fibre Channel Manager) to remotely manage and
monitor the health of the hub
Features
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel, Model S10 Short-Wave Hub
The front panel contains LEDs for monitoring power, fault, and port status. The RS-232
port is provided to configure and troubleshoot the hub and to upgrade its firmware. The
10Base-T port provides an ethernet connection if you choose to manage the hub with Fibre
Channel Manager.
The Reset button resets the internal control microprocessor of the hub. Pushing the Reset
button also forces loop initialization on all devices in the loop.
Figure 1 Front Panel Display, Short-Wave Hub
2
4
5
7
1
8
11
3
9
10
6
1 Power LED
2 Fault LED
7 10Base-T port
8 10Base-T Status LED
9 MAC address
3 Reset button
4 Fibre Channel connector (Port 1 indicated)
5 Port LED (Port 1 indicated)
10 RS-232 port
11 AC power connector
6 FC-AL short-wave ports and Port LEDs
14
Front Panel, Model S10 Short-Wave Hub
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel, Model L10 Long-Wave Hub
The front panel contains LEDs for monitoring power, fault, and port status. The long-wave
port is between port 9 and the 10Base-T port. The RS-232 port is provided to configure and
troubleshoot the hub and to upgrade its firmware. The 10Base-T port provides an ethernet
connection if you choose to manage the hub with Fibre Channel Manager.
The Reset button resets the internal control microprocessor of the hub. Pushing the Reset
button also forces loop initialization on all devices in the loop.
Figure 2 Front Panel Display, Long-Wave Hub
2
5
4
8
1
3
10
11
7
12
9
6
1 Power LED
2 Fault LED
7 FC-AL long-wave port and Port LED
8 10Base-T port
3 Reset button
9 10Base-T Status LED
10 MAC address
4 Fibre Channel connector (Port 1 indicated)
5 Port LED (Port 1 indicated)
11 RS-232 port
6 FC-AL short-wave ports and Port LEDs
12 AC power connector
Front Panel, Model L10 Long-Wave Hub
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear Panel, Short-Wave and Long-Wave Hubs
Three fans, located in a customer-replaceable module at the rear panel, cool the hub. If one
fan fails, the remaining two fans cool the hub temporarily, but it is important to replace the
module as soon as possible (see chapter 5, Maintenance and Replacement).
Figure 3 Rear Panel
fan air vents
Caution
Although the module will continue to run with two fans, a full complement of
fans ensures system and data integrity.
16
Rear Panel, Short-Wave and Long-Wave Hubs
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Topologies
Devices such as FC-AL disk arrays and HP system servers that support FC-AL can be
connected to the hub in a loop that includes one or more servers. All nodes in the loop
must be 1063 Mbps short-wave, non-OFC, FC-AL. The ports connected by a cable must
have the same optical transceivers. Figure 4, Figure 5, and Figure 6 show typical hub
topologies. For details on supported topologies, contact an HP sales representative.
Single Short-Wave Hub Topology
For the model S10 short-wave hub, Hewlett-Packard recommends 50-micron multimode
fiber cable for new installations, but also supports 62.5-micron multimode fiber cable with
SC-style connectors in existing installations. Stated distances assume 50-micron multimode
cable.
A server with an FC-AL short-wave adapter can connect to an hub 500 meters away. Each
of the 10 ports on the short-wave hub can connect to an FC-AL device up to 500 meters
away. The maximum distance between the server and the end FC-AL device is 1000 meters
(1 km).
Figure 4 Example Topology: 10 Ports Shared among Server and FC-AL Devices
NOTE: Connecting HP-UX servers
and HP NetServers to the same hub
is NOT a supported configuration.
HP-UX Server
or HP NetServer
HP-UX Server
or HP NetServer
model S10 hub
500 m
Total distance between server
and FC-AL device = 1000 m
..............................
..............................
... .....................
... ...
500 m
FC-AL Devices
Supported Topologies
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Cascaded Short-Wave Hub Topology
The example in Figure 5 shows two model S10 hubs connected in a cascade topology.
Cascaded short-wave hubs use one port on each hub for the hub-to-hub connection. Such a
configuration increases the potential distance between nodes in the loop an additional 500
meters. The maximum distance between the server and FC-AL devices with cascaded
short-wave hubs is 1500 meters (1.5 km).
Figure 5 Example Topology: Cascaded Short-Wave Hubs
Maximum distance between
server and FC-AL device = 1500 m
500 m
HP-UX Server
or
HP NetServer
model S10 hub
model S10 hub
..............................
..............................
..............................
... .....................
... ...
... .....................
... ......
NOTE: Connecting HP-UX
servers and HP NetServers
to the same hub is NOT
500 m
a supported configuration.
500 m
FC-AL Devices
FC-AL Devices
Cascaded hubs must have the same firmware versions to operate properly. If you are using
Fibre Channel Manager to manage cascaded hubs, configure the hub that has the LAN
(ethernet) connection as a parent hub and the remaining hub as a child hub (see
Configuring Cascaded Hubs on page 60).
18
Supported Topologies
Download from Www.Somanuals.com. All Manuals Search And Download.
Cascaded Long-Wave Hub Topology
Cascaded FC-AL, non-OFC, model L10 long-wave hubs use the long-wave port for the hub-
to-hub connection. The maximum supported distance between cascaded long-wave hubs
with single-mode 9 micron cable is 3 km. The maximum distance between a server and FC-
AL devices on cascaded long-wave hubs is, therefore, 4000 meters (500 m + 3000 m +
500 m). Under certain conditions, cascaded long-wave hubs are supported up to 10,000
meters (10 km) (see page 105 for more information). The 10-km capability only applies to
long-wave hubs connected to HP-UX servers.
Caution
When cascading long-wave hubs, only connect long-wave ports to long-wave
ports or short-wave ports to short-wave ports.
Ports 1 through 9 on each long-wave hub are for connections to FC-AL devices. Ports 1
through 9 can also be used in a cascaded configuration; however, the maximum distance
between hubs decreases from 3000 meters to 500 meters.
Figure 6 Example Topology: Cascaded Long-Wave Hubs
Maximum distance between
server and FC-AL device = 4000 m
NOTE: Under certain conditions, the
500 m
maximum distance between an HP-UX
HP-UX Server
server and FC-AL device can be 11,000 m.
or
model L10 hub
HP NetServer
..............................
..............................
..............................
NOTE: Connecting HP-UX
3000 m (long-wave port to long-wave port only)
model L10 hub
servers and HP NetServers
to the same hub is NOT
a supported configuration.
..............................
... ......
.................. ...
FC-AL Devices
500 m
FC-AL Devices
Supported Topologies
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Cascaded hubs must have the same firmware versions to operate properly. If you are using
Fibre Channel Manager to manage cascaded hubs, configure the hub that has the LAN
(ethernet) connection as a parent hub and the remaining hub as a child hub (see page 60
for more information).
20
Supported Topologies
Download from Www.Somanuals.com. All Manuals Search And Download.
2
INSTALLATION
Overview
Procedure 1: Prepare to Install the Hub
Procedure 2: Unpack the Hub
Procedure 3: Verify Hub Operation
Procedure 4: Mount the Hub into a Rack (Optional)
Procedure 5: Plan the FC-AL Connections
Procedure 6: Connect FC-AL Devices
Procedure 7: Verify the Connections
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
The procedures for installing an HP SureStore E model S10 or model L10 hub are the
following:
1. Prepare to install the hub.
2. Unpack the hub.
3. Verify hub operation.
4. Mount the hub in a rack (optional).
5. Plan the FC-AL connections.
6. Connect the FC-AL devices.
7. Verify the connections.
Read this chapter completely before installing the hub or attaching any FC-AL devices to
the hub.
22
Overview
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 1: Prepare to Install the Hub
Before installing the hub:
•
•
•
•
Complete site-required arrangements for the hub.
Make sure electrical power and temperature control requirements are met.
Define a strategy for integrating the hub into an existing loop.
Draw a map of all nodes to be connected to the hub.
Procedure 1: Prepare to Install the Hub
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 2: Unpack the Hub
1. Unpack and inspect the hub for damage that may have occurred during shipment.
2. Save the boxes and packing materials in case there is damage or anything needs to be
reshipped at a future date.
3. Verify that all items shown in Figure 7 are present. Contact an HP sales representative
if items are missing.
4. If the hub is to be used as a standalone unit, attach the four rubber feet to the bottom
corners of the hub. Optionally, remove the hub’s preinstalled mounting ear brackets and
nylon retainers. The brackets and retainers are used to mount the hub in a rack.
Figure 7 Standalone Product Contents
HP SureStore E Hub
Models S10 and L10
Service and User Manual
power cord
hub
nylon retainer
installed FC
port covers
rubber feet
loopback
cable
mounting
ear bracket
NOTE: The long-wave hub
includes an additional loopback
cable for the long-wave port.
24
Procedure 2: Unpack the Hub
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 3: Verify Hub Operation
By performing this procedure, you test the hub and verify that it operates properly before
you mount it in a rack or connect any devices to it.
1. To initialize the self-test, first plug the power cord into the hub and then into a power
receptacle. The hub does not have a power switch.
The hub runs the self-test each time the power cord is plugged in or the Reset button is
pressed.
Note
The hub’s power supply automatically adjusts to a range of 100 VAC ±10% or
240 VAC ±10%.
2. The hub finishes the self-test in less than 15 seconds.
If the Fault LED (amber) stays on after self-test, the hub failed. Refer to chapter 4,
Troubleshooting, or contact an HP service representative for assistance.
If the Power LED does not light, refer to chapter 4, Troubleshooting, or contact an HP
service representative.
Note
Interruptions to the hub’s AC power source initiate a self-test. Make sure the
power source circuits are properly grounded before using the supplied power
cord to connect the hub to the circuit.
3. Verify that each Fibre Channel port is operating properly. Insert the loopback cable into
the port and verify that the port status LED turns on. Both ends of the loopback cable
plug into the port connectors.
If you plan to use Fibre Channel Manager to manage the hub, continue with step 4. If you
do not plan to use Fibre Channel Manager or another hub management tool, go to step 7.
Procedure 3: Verify Hub Operation
25
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Verify that the 10Base-T port is operating properly. Insert an ethernet cable that is
connected to the LAN into the 10Base-T port, and verify that the 10Base-T status LED
turns on. (The status LED may begin flashing.)
5. Set the hub IP address and configure the hub as described in chapter 3, RS-232 Interface
Functions.
6. Verify the connection between the HP-UX server and the hub. At the management server
where Fibre Channel Manager is or will be installed, execute the following command:
/etc/ping <hub IP address>
Example: /etc/ping 15.43.214.13
Fibre Channel Manager requires HP-UX 10.20 or 11.0 on the management server.
If you are unable to ping the hub, refer to If the Management Server Cannot Ping the
Hub on page 78.
7. Unplug the hub.
26
Procedure 3: Verify Hub Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 4: Mount the Hub into a Rack (Optional)
The hub mounts into any standard HP 19-inch wide EIA cabinet. The hub’s front panel will
face the rear of the cabinet. The front of the hub contains the 10 Fibre Channel connectors.
You will need a T25 Torx head screwdriver to complete this procedure.
1. Record the serial number, located on the bottom of the hub, and the MAC address,
located under the 10Base-T port. The MAC address is unique and cannot be changed.
2. Verify that the rack is adequately secured and has enough space (1 EIA) for the hub.
Remove filler panels as needed from the front of the cabinet and open the rear door.
3. If the rubber feet are attached to the bottom of the hub, peel off the feet. Attach the
mounting ear brackets and nylon retainers if they are missing from the left and right
sides of the hub (Figure 8).
Secure the mounting ear brackets with three M3 x .5 screws to each front outside
corner, turning the angled end of the bracket outward. Attach the nylon retainers with
one screw through the center of the retainer and into the hole in each side of the hub.
Figure 8 Replacing Mounting Ear Brackets and Nylon Retainers
nylon retainer
1 M3x.5 machine screw
mounting ear bracket
3 M3x.5 machine screws
4. Slide a sheet metal nut onto the outer column in the back of the rack. Make sure to align
the hole in the nut with the hole at the selected EIA location on the column.
Procedure 4: Mount the Hub into a Rack (Optional)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Insert one end of the left rail in the adjoining slot. Line up the hole in the rail lines with
the holes in the nut and column (Figure 9).
6. Use a second sheet metal nut and repeat steps 4 and 5 to attach the other end of the rail
to the inner column on the front of the rack.
Note
DO NOT attach screws at this time.
Figure 9 Installing Rails
front of rack
rear of rack
28
Procedure 4: Mount the Hub into a Rack (Optional)
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Repeat step 4 through step 6 to install the right rail.
8. Position the hub in the rack. Align the hole in each mounting ear bracket with the holes
in the assembled rail, nut, and column.
9. Insert a 10–32 x .625 machine screw through the mounting ear bracket, rail, nut, and
column on each side of the hub (Figure 10). Tighten the screws.
Figure 10 Installing the Hub into the Rack
10. Slide the plenum shroud into the front side of the rack. Align the holes in the plenum
shroud brackets with the holes in the assembled rails and outer posts.
Procedure 4: Mount the Hub into a Rack (Optional)
29
Download from Www.Somanuals.com. All Manuals Search And Download.
11. Secure the brackets to the posts with 10–32 x .625 machine screws (Figure 11).
Figure 11 Installing the Plenum Shroud
plenum shroud
bracket
30
Procedure 4: Mount the Hub into a Rack (Optional)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 12 Hub Correctly Installed in a Rack
12. Plug the PDU cable into the cabinet PDU when you are ready to power on the hub. The
hub finishes the self-test in less than 15 seconds. Verify that the hub passes the self-test.
If the Fault LED (amber) stays on after self-test, the hub failed. Refer to chapter 4,
Troubleshooting, or contact an HP service representative for assistance.
If the Power LED is not lighted, refer to chapter 4, Troubleshooting, or contact an HP
service representative.
13. Reinstall filler panels over the plenum shroud.
Procedure 4: Mount the Hub into a Rack (Optional)
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 5: Plan the FC-AL Connections
The hub does not require drivers or specific versions of operating systems. However,
systems and FC-AL devices that can connect to the hub do have driver and operating
system requirements. Contact an HP sales representative for information on hardware and
software requirements for the systems or FC-AL devices you plan to connect to the hub.
The HP Fibre Channel Manager User Manual lists operating system requirements for
Fibre Channel Manager.
1. Verify that the loop cabling configuration is correct by comparing it to the cabling
examples on the following pages. Modify the network cabling map as needed.
Caution
Incorrect wiring can lead to problems such as devices left off the loop and
inaccessible by the server. Follow the guidelines below before starting.
2. Refer to your cabling map to review the user-assigned loop ID (hardware address) of
each FC-AL device to be connected to the hub, and verify that each ID is unique.
Duplicate IDs on the loop can cause problems.
3. Verify that the connections between the hub port and the FC-AL mass storage device or
the FC-AL adapter are of the same wave type and speed. For example, plan to connect
a short-wave port on the hub to a short-wave port on an FC-AL device.
4. Document the planned connections in a cabling map.
Correct Cabling Example for a Short-Wave Hub
For the model S10 short-wave hub, Hewlett-Packard recommends 50-micron multimode
fiber cable for new installations but also supports 62.5-micron multimode fiber cable with
SC-style connectors in existing installations.
32
Procedure 5: Plan the FC-AL Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
In a cascaded configuration of model S10 short-wave hubs, connect any port on the first
hub to any port on the second hub. Figure 13 includes all 18 nodes in the loop formed by
FC-AL Device 1, Hub A, Hub B, and FC-AL Device 2:
–
–
–
Port 1 on Hub A connects to FC-AL Device 1.
Port 10 of Hub A connects to Port 1 of Hub B.
Port 10 on Hub B connects to FC-AL Device 2.
In this configuration, any unused port on Hub A or Hub B can connect to any compatible
FC-AL device. This is just one example of cascaded short-wave hubs. The connection
between short-wave hubs can occupy any combination of ports.
Figure 13 Cascaded Short-Wave Hub Configuration
Short-Wave Hub A
Short-Wave Hub B
... ... ...... ... ... ... ...
... ... ...... ... ... ... ...
... ...
... ... ...... ... ... ... ...
... ...
... ... ...... ... ... ... ...
... ...
... ... ...... ... ... ... ...
... ...
... ... ...... ... ... ... ...
FC-AL Device 2
FC-AL Device 1
Note
If you plan to use Fibre Channel Manager to manage cascaded hubs, you must
configure the hub that has the LAN (ethernet) connection as a parent hub and
the remaining hub as a child hub (see Configuring Cascaded Hubs on page 60).
Correct Cabling Example for a Long-Wave Hub
Hewlett-Packard recommends 9-micron, single-mode fiber cable for the long-wave port.
For ports 1 through 9, the short-wave ports, Hewlett-Packard recommends 50-micron
multimode fiber cable for new installations but also supports 62.5-micron multimode fiber
cable with SC-style connectors in existing installations.
Procedure 5: Plan the FC-AL Connections
33
Download from Www.Somanuals.com. All Manuals Search And Download.
In a cascaded configuration of FC-AL long-wave hubs, connect the long-wave port on the
first hub to the long-wave port on the second hub. Figure 14 shows all 18 nodes in the loop
formed by FC-AL Device 1, Hub A, Hub B, and FC-AL Device 2:
–
–
–
Port 1 on Hub A connects to FC-AL Device 1.
The long-wave port of Hub A connects to the long-wave port of Hub B.
Port 1 on Hub B connects to FC-AL Device 2.
Long-wave hubs can be cascaded with ports 1 through 9 (the short-wave ports), but the
supported distance between hubs is reduced from 3000 meters to 500 meters. When
cascading long-wave hubs, ONLY connect long-wave ports to long-wave ports or short-
wave ports to short-wave ports. Any unused short-wave port on Hub A or Hub B can
connect to any compatible FC-AL device.
Figure 14 Cascaded Long-Wave Hub Configuration
Long-Wave Hub A
Long-Wave Hub B
...... ... ... ......... ... ... ...
...... ... ... ......... ... ... ...
...... ... ... ......... ... ... ...
...... ... ... ......... ... ... ...
...... ... ... ......... ... ... ...
...... ... ... ......... ... ... ...
FC-AL Device 1
FC-AL Device 2
Note
If you plan to use Fibre Channel Manager to manage cascaded hubs, you must
configure the hub that has the LAN (ethernet) connection as a parent hub and
the remaining hub as a child hub (see Configuring Cascaded Hubs on page 60).
34
Procedure 5: Plan the FC-AL Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Incorrect Cabling Examples
DO NOT cable together two ports on the same hub. Ports between the two connections
will be eliminated from the loop.
Figure 15 Incorrect Cabling Example: Connected Ports on the Same Hub
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
DO NOT leave cables that are connected to the hub disconnected at the opposite end of
the cable.
Figure 16 Incorrect Cabling Example: Disconnected Cable
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
Not connected
Procedure 5: Plan the FC-AL Connections
35
Download from Www.Somanuals.com. All Manuals Search And Download.
.
...
DO NOT attach more than one cable between any two hubs.
Figure 17 Incorrect Cabling Example: More Than One Cable Connection Between Hubs
... ... ... ... ... ...
... ... ... ... ... ...
.
... ... ... ... ... ...
... ... ... ...
... ... ... ...
... .
... ... ...
...
...
... ... ... ... ... ... ...
...
... ... ... ... ... ... ...
...
...
...
... ... ... ... ... ... ... ... ... ...
When cascading long-wave hubs, DO NOT connect the long-wave port to the short-wave
port on another hub. DO NOT connect long-wave FC-AL devices to long-wave hubs.
Figure 18 Incorrect Cabling Example: Long-Wave Port Connections to Wrong Device/Port
Long-Wave Hub A
Long-Wave Hub B
... ......... ...... ......... ...
... ......... ...... ......... ...
... ......... ...... ......... ...
... ......... ...... ......... ...
... ......... ...... ......... ...
... ...... ......... ......... ...
FC-AL Device 2
FC-AL Device 1
In the example in Figure 18:
–
The long-wave port on Hub A is incorrectly connected to Port 1, a short-wave port,
on Hub B.
–
A device other than the long-wave port of another hub is attached to the long-wave
port of Hub B.
The long-wave port of Hub A should be connected to the long-wave port of Hub B.
36
Procedure 5: Plan the FC-AL Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
Nonsupported Cabling Example
Connecting a hub to more than one other hub is NOT a supported configuration.
Figure 19 Nonsupported Cabling Example: More Than Two Hubs Connected
... ... ... ... ... ... ... ... ... ...
... ...
...
... . ...
... ... ... ... ... ... ...
.
.
.
.
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
.
.
.
.
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... .. ...
... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
.
.
...
...
.
... ...
.
Connecting an HP-UX server and HP NetServer to the same hub is NOT a supported
configuration.
Figure 20 Nonsupported Cabling Example: HP-UX Server and HP NetServer
Connected to Same Hub
HP-UX
Server
HP
NetServer
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
... ... ... ... ... ... ... ... ... ...
Procedure 5: Plan the FC-AL Connections
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 6: Connect FC-AL Devices
After the hub and devices are prepared, connect FC-AL devices as follows:
1. Physically set each FC-AL device to a unique loop ID (hardware address). Refer to the
FC-AL device’s manual to set the loop ID.
If devices are added during normal operation and duplicate IDs occur, the Fibre
Channel driver denies access to both devices until the address conflict is resolved.
Change the address of the second (duplicating) device.
If devices are added or device addresses changed while the system is powered off
and duplicate IDs occur, the system is unavailable until the address conflict is resolved.
An error message appears on the system console. Change the address of the second
(duplicating) device.
2. Remove the covers from the FC-AL ports. Refer to your cabling map, and begin
connecting devices to the hub. Leave the covers on ports not in use.
Caution
Fiber optic cables and connectors are extremely fragile. Avoid twisting or
bending the cable beyond a 3-cm radius.
If the hub and all FC-AL devices are powered down, first plug in the hub, then
power on the devices at all the FC-AL nodes on the loop. The hub should be the first
operating component in the loop.
If the hub and all devices are powered up, you can connect the hub to a server or
FC-AL device while the server or FC-AL device is operating.
38
Procedure 6: Connect FC-AL Devices
Download from Www.Somanuals.com. All Manuals Search And Download.
If the hub is to be connected to an FC-AL adapter that is connected to another FC-AL
device, follow the removal procedures in the document that came with the FC-AL
device before disconnecting the device’s cable.
If the hub is to be connected to an FC-AL device that is connected directly to a server,
follow the removal procedures in the document that came with the FC-AL device
before disconnecting the device’s cable.
When installing model L10 long-wave hubs in a cascaded topology, make sure the
long-wave port is connected only to the long-wave port on another long-wave hub.
3. For the model L10 long-wave hub, connect the long-wave loopback cable to the
long-wave port if the port is not in use.
4. Install any special files the FC-AL devices need. Refer to the device manual for details.
Procedure 6: Connect FC-AL Devices
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 7: Verify the Connections
After connecting devices and the server to the hub, verify the connections.
Note
Because the hub is strictly a pass-through device for FC-AL traffic, there is no
hub address and the hub is not listed in ioscan output (HP-UX servers) or the
SCSI Adapters window (HP NetServers).
For HP-UX servers:
1. Use the following HP-UX command to run ioscan and check the hardware paths
between the server and the attached FC-AL devices:
ioscan -f
For details on ioscan and its options, refer to the HP-UX System Administration
Tasks Manual. Also consult the device documentation to interpret the ioscan output.
2. If the Hardware State of a device connected to the hub is “Unclaimed” or “No H/W,” see
chapter 4, Troubleshooting, for more information.
For HP NetServers:
1. From the Start menu, select Settings, then select Control Panel.
2. Double-click the SCSI Adapters icon. The SCSI Adapters window appears.
3. Click the Devices tab, then verify that the FC-AL devices connected to the hub are
displayed.
40
Procedure 7: Verify the Connections
Download from Www.Somanuals.com. All Manuals Search And Download.
3
RS-232 INTERFACE FUNCTIONS
Overview
Setting Up an RS-232 Connection
Updating the Hub Firmware
Enabling Hub Management
Running Diagnostic Tests
Viewing Hub Information
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
This chapter describes how to use the RS-232 port to update firmware, enable hub
management, run diagnostic tests, and view hub information. The RS-232 port is located on
the front panel of the hub (see Figure 1 on page 14 or Figure 2 on page 15).
To configure the hub for Fibre Channel Manager or another management application, use
the hub’s configuration menus to set SNMP values and the IP address.
If you do not plan to manage the hub with Fibre Channel Manager or another management
application, you do not have to update the firmware or enable hub management. You do not
have to update hub firmware to run diagnostic tests or view hub information.
Before beginning the procedures in this chapter, determine the configuration values that
are required for the hub. Obtain IP addresses from the network administrator for the LAN
to which the parent hub is connected. IP addresses are optional for the child hub. Values
can be written in the spaces of the following worksheet.
Table 1 Worksheet for Hub Configuration
Parameter
Parent Hub
Child Hub (if any)
Firmware version (hub controller)
Firmware version (device agent)
Proxy master option
Same as parent
Same as parent
DISABLED
ENABLED
DISABLED
Port bypass persistence option
Hub IP address
DISABLED
Subnet mask
Default gateway address
Trap IP address (optional, max. of 4)
Trap IP address (optional, max. of 4)
Trap IP address (optional, max. of 4)
Trap IP address (optional, max. of 4)
42
Overview
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1 Worksheet for Hub Configuration (cont’d)
Parameter
Parent Hub
Child Hub (if any)
SNMP get community name
SNMP set community name
SNMP trap community name
About the RS-232 Main Menu
When you set up an RS-232 connection and boot the hub, the hub management Main menu
appears on the terminal screen.
Fibre Channel Hub Model Number:
Device Agent Version:
HP3724A
02.14
Hub Controller Version:
03.06
Agent Boot PROM Version:
01.04
Status of Device Agent self-test:
Status of Hub Controller self-test:
passed
passed
1. Reset hub and run self-test
2. Set Networking parameters
3. Management options
4. Hub information
The model and version numbers displayed can be different from the examples shown in
this manual. Fewer menu options are displayed in earlier versions of the hub firmware. To
update the firmware, follow the instructions given in Updating the Hub Firmware on
page 48.
If the Main menu does not appear and the display shows the following message, press the
Reset button on the front panel of the hub.
pROBE+>
The Main menu provides four options:
1. Reset hub and run self-test
This option resets the hub and runs the diagnostic tests. When changes are made to
the hub, they do not take effect until the hub is reset.
Overview
43
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Set Networking parameters
Use this option to view or change the hub network configuration, including the IP
address. For cascaded hubs, use this option to define parent/child relationships.
3. Management options
This option displays a menu for changing SNMP values.
4. Hub information
Use this option to view the media access control (MAC) address and serial number.
Tips for Using the RS-232 Interface
•
To enter a command, type the number that corresponds to the desired option, then press
<ENTER>. An appropriate submenu appears.
•
To enter a value, type the value and then press <ENTER>. To enter multiple values, enter
each one separately.
•
•
Enter 1 to return to the previous menu or option.
From the Main menu, enter 1 to reset the hub. New self-test values are displayed after
the hub has been reset.
•
When you have finished making changes, you can close the terminal connection and
disconnect the serial cable.
44
Overview
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting Up an RS-232 Connection
The RS-232 interface requires a connection from the hub to a dumb terminal or to a PC with
a terminal emulator program. A PC is required for updating firmware. To access the hub
configuration menus, you can use either a PC or a dumb terminal.
Setting Up a Connection to a PC
Setting up a PC connection requires the following equipment:
•
•
•
FC-AL hub
A personal computer, such as an OmniBook notebook PC
A null-modem serial cable
The cable must have a DB-9 female connector for connection to the hub. For example,
for an OmniBook notebook PC, you can use an HP 24542U RS-232 cable, which has
two DB-9 female connectors.
•
Terminal emulation software, such as HyperTerminal
The terminal emulator must be capable of ASCII text file transfers and support VT100
or ANSI emulation with no flow control.
To establish a connection, do the following:
1. Connect the serial cable between the RS-232 port on the hub and a serial (COM) port on
the PC.
Setting Up an RS-232 Connection
45
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Run the terminal emulator application. Configure the terminal emulator to use the
following settings:
Baud rate:
Data bits:
19,200
8
Parity bits:
Stop bits:
none
1
Parity check:
Flow control:
off
none
3. Press <ENTER> to display the hub configuration Main menu.
If the Main menu does not appear and the following message is displayed, press the
Reset button on the front panel of the hub:
pROBE+>
Setting Up a Connection to a Dumb Terminal
Setting up a connection between a dumb terminal and the hub requires the following
equipment:
•
•
FC-AL hub
Any terminal that supports VT100 emulation with no flow control
The terminal must be in vt100 mode before you continue with this procedure. Refer to
the terminal’s manual for more information.
•
A null-modem serial cable
The cable must have a DB-9 female connector for connection to the hub.
To establish a connection, do the following:
1. Connect the serial cable between the RS-232 ports on the hub and the terminal.
2. Power on the terminal.
46
Setting Up an RS-232 Connection
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Configure the terminal to use the following settings:
Baud rate:
Data bits:
19,200
8
Parity bits:
Stop bits:
none
1
Parity check:
Flow control:
off
none
4. Press <ENTER> to display the hub configuration Main menu.
If the Main menu does not appear and the following message is displayed, press the
Reset button on the front panel of the hub.
pROBE+>
Setting Up an RS-232 Connection
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Updating the Hub Firmware
The hub’s management tool, Fibre Channel Manager, requires the following versions of hub
firmware: .
Device Agent
Hub Controller
02.14 (or higher)
03.06 (or higher)
Before you begin this procedure, determine whether the hub requires a firmware update to
communicate with Fibre Channel Manager. A label on the bottom of the hub chassis lists
the EDC datecode. If the EDC datecode is C-38XX or higher, the hub has the required
firmware.If you are not able to access the label, determine the firmware versions by
connecting to the hub’s RS-232 interface (see Setting Up an RS-232 Connection on page 45).
To update the hub firmware, use a PC connected to the hub. First copy the firmware files to
the PC and then transfer the firmware from the PC to the hub.
The general process for updating the hub firmware is the following:
1. Obtain the current firmware.
2. Reboot the hub.
3. Update the hub controller firmware.
4. Update the hub device agent code.
5. Reset the hub.
6. Set manufacturing values.
If any hubs are cascaded, repeat the procedures for each child hub. Parent and child hubs
must have identical versions of the firmware.
The procedures in this section require a total of 30 to 60 minutes to complete.
48
Updating the Hub Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
Caution
If a hub power failure occurs during the transfer of the new firmware to the hub,
the hub can become inoperable.
Procedure 1: Obtain the Current Firmware
The current release of the hub firmware is available at the Hewlett-Packard Software
Depot.
1. From a Netscape browser window, enter the URL for the Hewlett-Packard Software
Depot (http://www.software.hp.com).
2. Click the Network & Systems Administration link, then click theHP Fibre Channel
Manager link.
3. Click the Download Hub firmware link on the HP Fibre Channel Manager home page.
The firmware files are available as a self-extracting ZIP file for Windows and as a
compressed tar file for HP-UX. These compressed files include the current and
previous release version of the firmware. The previous release versions are necessary
if you need to recover from an unsuccessful firmware update.
4. Follow the instructions at the web site to download the firmware files.
5. Copy the files to the PC you will use to download the new firmware files to the hub.
Procedure 2: Reboot the Hub
1. Set up an RS-232 connection as described in Setting Up a Connection to a PC on page 45.
2. After the hub configuration Main menu appears, enter 1 to reset the hub.
The screen begins to display the status of the hub. To reboot, you must interrupt the
status display to go to the Boot menu.
3. Wait for the following message:
Press Enter key for Boot Menu, Agent boot in 6 seconds
Updating the Hub Firmware
49
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Immediately press <ENTER> to display the Boot menu:
Boot menu V01.04
1. Download and update Device Agent code
2. Download and update Hub-Controller code
3. Reset hub and run self test
4. Start Normal Hub operation
Caution
Do not update the device agent code at this time. The hub controller firmware
must be updated first.The hub will not operate properly if the firmware is
updated in the wrong sequence. See If Firmware Upgrade Appears to Fail on
page 79 if the firmware is updated in the wrong sequence.
Procedure 3: Update the Hub Controller Firmware
1. From the Boot menu, enter 2 to update the hub controller firmware. A prompt appears
for you to begin file transfer; for example:
Ready to download Hub-Controller code to RAM
Start ASCII file (S-record format) transfer now
<Refer to terminal emulator user manual for instructions>
Press control-C at any time to cancel
2. From the terminal emulator application, select the transfer option to send a text file.
The hub’s firmware files have a .frm suffix. Verify that the terminal emulator application
is displaying all file types.
3. Send the following file you downloaded from the web site. (Firmware filenames change
when updated versions are released. Always check the Hewlett-Packard Software
Depot for the latest firmware version and download instructions.) The default directory
for this file is C:\Temp\HUB_FW.
IFCH3820.FRM
Several rows of dots appear to indicate download progress; for example:
...................................................................
...................................................................
....................................
50
Updating the Hub Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
After a few minutes, the transfer prompt appears; for example:
Done, memory range [$00001000:$00004FFF]
Ready to transfer Hub-Controller code from RAM to FLASH
Note, once started, this step must not be interrupted
Press Enter to start, control-C to cancel
The values displayed for memory range represent low-level diagnostics; the values
displayed in the status message can be different from the values shown here.
4. Press <ENTER>. Additional progress indicators and status messages appear; for
example:
--+
$..................................................................
*******************************************************************
************************
The hub is automatically rebooted and additional messages appear:
DRAM test
SEEPROM test
(this will take about 10 seconds) > passed
(this will take about 1 second) > passed
FLASH checksum (this will take about 2 seconds) > passed
Press Enter key for Boot Menu, Agent boot in 7 seconds
To reboot, you must interrupt the display to go to the Boot menu.
5. Immediately press <ENTER> to display the Boot menu.
Note
If the Main menu appears instead of the messages above, enter 1 to reboot the
hub, then press <ENTER> before the timeout period is finished.
If the Main menu appears, ignore the Hub Controller version number. It may be
blank or UNKNOWN. If the version number is blank or UNKNOWN, the upgrade
version number will appear in the Main menu after you update the Hub Device
Agent code and reset the hub.
Updating the Hub Firmware
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Procedure 4: Update the Hub Device Agent Code
Caution
The hub controller firmware must be updated before the device agent code.
The hub will not operate properly if the firmware is updated in the wrong
sequence. See If Firmware Upgrade Appears to Fail on page 79 if the firmware
is updated in the wrong sequence.
1. From the Boot menu, enter 1 to update the device agent code. A prompt appears for you
to begin file transfer; for example:
Ready to download Device Agent code to RAM
Start ASCII file (S-record format) transfer now
<Refer to terminal emulator user manual for instructions>
Press control-C at any time to cancel
2. From the terminal emulator application, select the transfer option to send a text file.
The hub’s firmware files have a .frm suffix. Verify that the terminal emulator application
is displaying all file types.
3. Send the following file you downloaded from the web site. (Firmware filenames change
when updated versions are released. Always check the Hewlett-Packard Software
Depot for the latest firmware version and download instructions.) The default directory
for this file is C:\Temp\HUB_FW.
IFCH3821.FRM
The screen is filled with rows of progress indicator dots as the file is transferred; for
example:
...................................................................
...................................................................
....................................
The transfer process can take 10 to 40 minutes. When the file transfer has been
completed, status messages and a transfer prompt appear; for example:
Done, memory range [$00001000:$0005D666]
Ready to transfer Device Agent code from RAM to FLASH
Note, once started, this step must not be interrupted
Press Enter to start, control-C to cancel
52
Updating the Hub Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
The values displayed for memory range represent low-level diagnostics; the values
displayed in the status message can be different from the values shown here.
4. Press <ENTER>. The screen displays status messages; for example:
FLASH programming will take about 40 seconds
FLASH pgm:[$001000:$101000)->[$800000:$900000) >
Caution
Do not interrupt the display or press any keys during this process.
After about 40 seconds, the display continues.
When FLASH programming is completed, the checksum appears; for example:
FLASH programming will take about 40 seconds
FLASH pgm:[$001000:$101000)->[$800000:$900000) > complete, no errors
New FLASH checksum = 0x7B04
The value displayed can be different from the example shown here. Then the Boot
menu appears again.
Procedure 5: Reset the Hub
After updating the hub firmware, you must reset the hub for the new firmware to take
effect.
1. From the Boot menu, enter 3 to reset the hub and run the hub self-test. The Main menu
appears and displays the new hub controller and device agent code version numbers.
2. Verify that the upgrade version numbers are displayed, then go to Procedure 6: Set
Manufacturing Values.
If the Main menu displays the Hub Controller version as Unknown, continue with step 3.
Updating the Hub Firmware
53
Download from Www.Somanuals.com. All Manuals Search And Download.
3. From the Main menu, enter 2 (Set Networking parameters) to display the Network
Setup menu.
Network Setup Menu:
1. Return to Main Menu
2. Select IP address [current = nnn.nnn.nnn.nnn]
3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn]
4. Select Default Gateway address [current = nnn.nnn.nnn.nnn]
5. Save Network Setup changes and reboot
6. Proxy Master Setup
4. Enter 6 to display the Proxy Master menu:
Proxy Master Menu: <Current state: Proxy Master DISABLED>
1. Return to previous Menu
2. Toggle current Proxy Master state and reboot
5. Enter 2 to change the Proxy Master setting to ENABLEDand reboot the hub. When the
Main menu appears, verify the new Hub Controller version.
Procedure 6: Set Manufacturing Values
After resetting the hub and verifying the new firmware versions, set the system.sysDescr
and system.sysObjectID values.
1. From the Main menu, enter mfg to display the Manufacturing Settings Menu.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = ]
3. Set system OID [current = 1.3.6.1.4.1]
4. Toggle port bypass persistence mode [current = Enabled]
>
2. Enter 2 to display the Set sysDescr string Menu.
Set sysDescr string Menu: [current = ]
1. Return to Manufacturing Settings Menu
or enter new sysDescr string
>
54
Updating the Hub Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
3. For the model S10 short-wave hub, enter: HP A3724A FC-AL Shortwave Hub
For the model L10 long-wave hub, enter: HP A4839A FC-AL Longwave Hub
The Set sysDescr string Menu appears with the new setting. (The following example is
for the short-wave hub.)
Set sysDescr string Menu: [current = HP A3724A FC-AL Shortwave Hub]
1. Return to Manufacturing Settings Menu
or enter new sysDescr string
>
4. Verify that the setting is correct, then enter 1 to return to the Manufacturing Settings
Menu.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = HP A3724A FC-AL Shortwave Hub]
3. Set system OID [current = 1.3.6.1.4.1]
4. Toggle port bypass persistence mode [current = Enabled]
>
5. Enter 3 to display the Set System OID Menu.
Set System OID Menu: [current = 1.3.6.1.4.1]
1. Return to Manufacturing Settings Menu
or enter new system OID suffix in dotted decimal format
The suffix entered will be appended to 1.3.6.1.4.1
example: if desired system OID is 1.3.6.1.4.1.2.3.4, then enter
2.3.4
>
6. Enter 11.2.3.7.5.10
Updating the Hub Firmware
55
Download from Www.Somanuals.com. All Manuals Search And Download.
The Set System OID Menu appears with the new setting.
Set System OID Menu: [current = 1.3.6.1.4.1.11.2.3.7.5.10]
1. Return to Manufacturing Settings Menu
or enter new system OID suffix in dotted decimal format
The suffix entered will be appended to 1.3.6.1.4.1
example: if desired system OID is 1.3.6.1.4.1.2.3.4, then enter
2.3.4
>
7. Verify that the setting is correct, then enter 1 to return to the Manufacturing Settings
Menu.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = HP A3724A FC-AL Shortwave Hub]
3. Set system OID [current = 1.3.6.1.4.1.11.2.3.7.5.10]
4. Toggle port bypass persistence mode [current = Enabled]
>
If you are using Fibre Channel Manager to manage the hub, the bypass persistence setting
controls the behavior of bypassed ports when the hub is power cycled or reset.
If the hub is power-cycled or reset with bypass persistence disabled, the hub
automatically enables all ports that were previously bypassed in Fibre Channel Manager. If
the hub is reset with bypass persistence enabled, the hub continues to bypass ports that
were bypassed in Fibre Channel Manager.
8. Enter 4 to disable port bypass persistence. Verify that the port bypass persistence mode
is disabled.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = HP A3724A FC-AL Shortwave Hub]
3. Set system OID [current = 1.3.6.1.4.1.11.2.3.7.5.10]
4. Toggle port bypass persistence mode [current = Disabled]
>
9. Enter 1 to return to the Main menu.
10. Exit the terminal emulator application and disconnect the serial cable from the hub and
the PC.
56
Updating the Hub Firmware
Download from Www.Somanuals.com. All Manuals Search And Download.
Enabling Hub Management
Use the hub RS-232 management menus to enable the hub to be managed by Fibre Channel
Manager. To enable hub management:
•
•
•
Set hub IP address and network configuration options.
Set SNMP values.
Configure cascaded hubs (if you plan to manage hubs in a cascaded configuration).
Setting Hub IP Address and Network Configuration Options
Use this procedure to set the following parameters on the hub.
•
•
•
Hub IP address
Subnetworking mask
Default gateway address
If you have hubs in a cascaded configuration, only perform this procedure for the parent
hub. The parent hub should be the hub that has the LAN (ethernet) connection. Refer to the
values you entered in Table 1 on page 42 as you set the above parameters.
To set hub IP address and network configuration options:
1. Set up an RS-232 connection between the parent hub and a PC or dumb terminal (see
Setting Up a Connection to a PC on page 45 or Setting Up a Connection to a Dumb
Terminal on page 46).
Enabling Hub Management
57
Download from Www.Somanuals.com. All Manuals Search And Download.
2. From the Main menu, enter 2 (Set Networking parameters) to display the Network
Setup menu:
Network Setup Menu:
1. Return to Main Menu
2. Select IP address [current = nnn.nnn.nnn.nnn]
3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn]
4. Select Default Gateway address [current = nnn.nnn.nnn.nnn]
5. Save Network Setup changes and reboot
6. Proxy Master Setup
3. Enter 2 to set the hub IP address. A command prompt appears.
4. Type the IP address for the hub, then press <ENTER>.
5. Enter 3 to set the Subnetworking Mask. A command prompt appears.
6. Type the Subnetworking Mask for the hub, then press <ENTER>.
7. Enter 4 to set the Default Gateway address. A command prompt appears.
8. Type the Default Gateway address for the hub, then press <ENTER>.
9. Enter 5 to save your changes. The hub is rebooted with the new values. The Main menu
appears.
Caution
You must enter 5 to save changes. If you do not want to change the hub values,
do not enter 5. Instead, enter 1 to return to the Main menu.
Verifying and Setting SNMP Values
Use the following procedure to set the following SNMP values. If you have hubs in a
cascaded configuration, only perform this procedure for the parent hub. The parent hub
should be the hub that has the LAN (ethernet) connection. Refer to the values you entered
in Table 1 on page 42 as you set the above parameters.
•
get community name
58
Enabling Hub Management
Download from Www.Somanuals.com. All Manuals Search And Download.
The get community name must be the same name used when a device was added to
Fibre Channel Manager. If the names are not identical, Fibre Channel Manager cannot
report management information for this hub. The default value is public.
•
set community name
The set community name must be the same name used when a device was added to
Fibre Channel Manager. If the names are not identical, Fibre Channel Manager cannot
set management parameters for this hub. The default value is private.
•
•
SNMP trap community name
The hub includes the trap community name in event messages sent to the management
application. The default value is SNMP_trap.
trap server IP addresses
This option sets the destination addresses for SNMP event messages. A maximum of
four addresses can be specified.
Caution
If you enter the name of an existing IP address, the existing address is deleted.
•
•
MIB-2 system name
This value is returned for the SNMP MIB-2 system.sysName variable.
default values
This option resets the get, set, and trap community names to the default values.
To verify and set SNMP values, do the following:
1. Verify with your network administrator that the default get community name is
acceptable. The default is public.
2. Verify with your network administrator that the default set community name is
acceptable. The default is private.
3. Verify with your network administrator that the default trap community name is
acceptable. The default is SNMP_trap.
Enabling Hub Management
59
Download from Www.Somanuals.com. All Manuals Search And Download.
4. From the Main menu, enter 3 (Management options) to display the Management
Options menu:
Management options Menu:
1. Return to Main Menu
2. Set SNMP get community name
3. Set SNMP set community name
4. Set SNMP trap community name
5. Set SNMP trap server IP addresses
6. Set MIB-2 sysname
7. Restore default values to SNMP get, set, trap community names
8. Clear SNMP trap server IP address list
5. Enter 5 to set the IP address(es) where you want Fibre Channel Manager to send traps
(optional). The Set Trap IP address Menu appears.
6. Type the trap server IP address, then press <ENTER>.
To enter additional addresses, repeat step 6. You can enter up to four IP addresses.
To delete an existing trap server IP address, enter the value of the existing IP address.
7. Enter 1 to return to the Management Options menu.
8. Enter 6 to set the MIB-2 sysname (optional). The SNMP MIB-2 sysName Menu appears.
9. Type a unique name for the hub, then press <ENTER>.
10. Enter 1 to return to the Management Options menu, then enter 1 again to return to the
Main menu.
Configuring Cascaded Hubs
By default, HP SureStore E hubs are configured as parent hubs. However, you can connect
two hubs in a cascaded configuration in which one hub (the parent) is connected to the
LAN (ethernet) and the other hub (the child) is connected to the parent hub. For
information about setting up a cascaded hub configuration, see page 18 and page 32.
60
Enabling Hub Management
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring the Parent Hub
If you plan to manage cascaded hubs with Fibre Channel Manager, configure the hub
connected to the LAN as a parent hub.
1. From the Main menu, enter 2 (Set Networking parameters) to display the Network
Setup menu.
Network Setup Menu:
1. Return to Main Menu
2. Select IP address [current = nnn.nnn.nnn.nnn]
3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn]
4. Select Default Gateway address [current = nnn.nnn.nnn.nnn]
5. Save Network Setup changes and reboot
6. Proxy Master Setup
2. Enter 6 to display the Proxy Master menu:
Proxy Master Menu: <Current state: Proxy Master ENABLED>
1. Return to previous Menu
2. Toggle current Proxy Master state and reboot
For the parent hub, verify that the master is ENABLED, then enter 1 to return to the
Network Setup menu. Enter 1 again to return to the Main menu.
3. Enter 5 to save your changes. The hub is rebooted with the new values.
4. Close the terminal connection and disconnect the serial cable.
Configuring the Child Hub
If you plan to manage cascaded hubs with Fibre Channel Manager, configure the hub that is
connected to the parent hub as a child hub.
1. Set up an RS-232 connection between the child hub and a PC or dumb terminal (see
Setting Up a Connection to a PC on page 45 or Setting Up a Connection to a Dumb
Terminal on page 46).
Enabling Hub Management
61
Download from Www.Somanuals.com. All Manuals Search And Download.
2. From the Main menu, enter 3 (Management options) to display Management Options
menu:
Management options Menu:
1. Return to Main Menu
2. Set SNMP get community name
3. Set SNMP set community name
4. Set SNMP trap community name
5. Set SNMP trap server IP addresses
6. Set MIB-2 sysname
7. Restore default values to SNMP get, set, trap community names
8. Clear SNMP trap server IP address list
3. Enter 6 to set the MIB-2 sysname for the child hub (optional).
4. Type a unique name for the child hub, then press <ENTER>.
5. Enter 1 to return to the Management Options menu, then enter 1 again to return to the
Main menu.
6. From the Main menu, enter 2 (Set Networking parameters) to display the Network
Setup menu.
Network Setup Menu:
1. Return to Main Menu
2. Select IP address [current = nnn.nnn.nnn.nnn]
3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn]
4. Select Default Gateway address [current = nnn.nnn.nnn.nnn]
5. Save Network Setup changes and reboot
6. Proxy Master Setup
7. From the Network Setup menu, enter 6 to display the Proxy Master menu:
Proxy Master Menu: <Current state: Proxy Master ENABLED>
1. Return to previous Menu
2. Toggle current Proxy Master state and reboot
8. To disable the proxy master option (configure the hub as a child), enter 2. The hub is
rebooted automatically and the Main menu reappears.
To verify that the hub is configured as a child, return to the Proxy Master menu. The
proxy master state for a child hub is displayed as “DISABLED.”
62
Enabling Hub Management
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Close the terminal connection and disconnect the serial cable from the child hub.
Connecting the Hubs
Connect the parent hub to the child hub. See page 32 to connect short-wave hubs and
page 33 to connect long-wave hubs. See page 17 for information on supported cascaded
topologies.
Enabling Hub Management
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Running Diagnostic Tests
When a problem occurs in the hub, the amber Fault LED comes on. A fault can occur for
many reasons, including:
•
•
•
Elevated internal temperature
Power supply failure
Fan malfunction
To determine the cause of the problem, run the hub self-test from the Main menu.
1. Set up an RS-232 connection between the hub and a PC or dumb terminal (see Setting
Up a Connection to a PC on page 45 or Setting Up a Connection to a Dumb Terminal on
page 46).
2. From the Main menu, enter 1 to reset the hub and run the self-test. If the hub fails the
self-test, an error number is displayed; for example:
Status of Hub Controller self-test:
0200
A value of 0200 in the self-test represents a fan failure. Replace the fan module as
described in Replacing the Fan Module on page 88.
Any other numeric value represents an internal hub failure. Internal parts are not
replaceable. If an internal malfunction occurs, replace the hub.
WARNING
Do not attempt to open the hub chassis. Uninsulated parts inside the
chassis constitute a hazard.
3. After correcting any problems, enter 1 to reset the hub.
For normal hub operation, the Hub Controller self-test status is displayed as “passed.” For
a child hub, the Hub Controller self-test status is displayed as “Unknown.”
64
Running Diagnostic Tests
Download from Www.Somanuals.com. All Manuals Search And Download.
Viewing Hub Information
Use the Hub Information menu to view the following hub identification information:
•
•
•
MAC address
Child device
Serial number
To view hub information:
1. From the Main menu, enter 4 (Hub Information) to display the MAC address. The MAC
address and the Hub Information menu appear; for example:
MAC address: 0060b0-5e0827
1. Return to previous Menu
2. Display list of proxied devices
The MAC address is unique for each hub and cannot be changed.
2. To display additional information, enter 2. This option displays the serial number of the
hub and any child hub connected to it; for example:
1. Local Hub-Controller: Model#:HP A3724A, Serial#:usg1001028, Ver:03.06
2. Remote Hub-Controller: Model#:HP A3724A, Serial#:usg1001023, Ver:03.06
Item 1 represents information for the hub, including model number and hub controller
firmware version number. If another hub is cascaded to this hub, information about the
child hub is displayed as item 2. A child hub appears only if the Proxy Master
parameter is enabled and the ports of the two hubs are connected.
For instructions on how to configure a hub as a child hub, see Configuring the Child
Hub on page 61.
3. To return to the Main menu, enter 1.
Viewing Hub Information
65
Download from Www.Somanuals.com. All Manuals Search And Download.
66
Viewing Hub Information
Download from Www.Somanuals.com. All Manuals Search And Download.
4
TROUBLESHOOTING
Troubleshooting Procedures
LED Indicators
If the Power LED Is Off
If the Hub Fault LED Stays on After Self-Test
If a Fan Is Not Operating
If a Device Is Unlisted/UNCLAIMED in ioscan or Not
Displayed in SCSI Adapters Window
If a Port LED Is Off
If a Port LED Is On When It Should Be Off
If the Management Server Cannot Ping the Hub
If Firmware Upgrade Appears to Fail
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Procedures
If there is a problem accessing a device connected to the hub, the source of the problem
can be with the device, the hub, the host, or any of the connections between the host and
the device. Follow the steps below to investigate the problem from the most likely to the
least likely cause. In addition, check the troubleshooting tables in this chapter for solutions
to specific symptoms.
1. For HP-UX servers, run ioscan from the server’s console.
–
–
If the hardware paths for all FC-AL devices connected to the hub are listed in ioscan,
the connection from the host to the device is good, and problems accessing a device
probably originate in the software, driver, or device.
If the hardware path for a FC-AL device connected to the hub is not listed in ioscan,
the source of the problem is likely to be bad connections, duplicate hardware
addresses, a faulty device, or a faulty hub (see steps 2 through 5). The hub does not
appear in ioscan output because it does not have a hardware address.
For HP NetServers, open the SCSI Adapters window, then click the Devices tab. If
the device is not displayed, the problem is likely to be bad connections, duplicate
hardware addresses, a faulty device, or a faulty hub (see steps 2 through 5). The hub
does not appear in this window because it does not have a hardware address.
2. Inspect the cabling between the hub and FC-AL devices. Check for loose, dirty,
broken, or bent cabling and connectors. Cables should attach with an audible click.
3. Check the loop ID (hardware address) of each device on the loop and eliminate
any duplicate addresses. Reset the hub after changing any loop ID, then run ioscan to
make sure there are no duplicate addresses. Duplicate addresses can be indicated by
“NO H/W” in the S/W State field.
4. Inspect the FC-AL device for a fault. Follow the instructions that came with the
device. Make sure you check the fiber optic transmit or receiving port on the device.
5. Inspect the hub LED indicators for apparent problems (see Table 2 on page 70). If
the Fault LED is lit, either the fans or the hub is faulty. If a cable is connected to a port
68
Troubleshooting Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
and the corresponding port LED is not lit, try replacing the cable with a loopback cable
to determine if the problem is with the cable or the port. For the long-wave hub, use the
long-wave loopback cable (A4839-63001) if you are testing the long-wave port.
Troubleshooting Procedures
69
Download from Www.Somanuals.com. All Manuals Search And Download.
LED Indicators
Table 2 LED Indications
LED Pattern
Label
and Color
Indication
Possible Causes
Power
steady – green
Hub is powered on.
Normal state
flashing - green Power is intermittent.
– Fibre Channel Manager is set to beacon
(flash) the Power LED (normal state).
– Line voltage is inadequate.
– Hub is faulty.
blank – off
No power to hub.
– Line has no voltage.
– Hub is disconnected, or power cable is bad.
– Hub is faulty.
Fault
steady – amber Hub is running self-test. If self-test fails, hub detected either:
If light remains on after
20 seconds, hub failed
– A faulty hub
self-test.
– A faulty fan module
blank – not on
Self-test completed or
power is off. (Power
LED is also off.)
Normal running or off state
Ports
1-10
steady – green
blank – not on
FC-AL connection to
this port is valid.
Normal state for a connected port
Port for this LED is
inactive.
Port is being bypassed because:
– Port is not connected to another device.
– Port was bypassed in Fibre Channel
Manager.
– Attached FC-AL device is faulty or turned
off.
– Port is faulty.
– Cable or connector is faulty.
70
LED Indicators
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2 LED Indications (cont’d)
LED Pattern
Label
and Color
Indication
Possible Causes
10Base-T flashing – green Ethernet connection to
hub is valid.
Normal state
LED Indicators
71
Download from Www.Somanuals.com. All Manuals Search And Download.
If the Power LED Is Off
If the Power LED is off, find the symptom that best fits the situation, then attempt the
solution. When more than one solution is possible, the most likely one is listed first.
Symptom
Cause/Solution
The hub is installed, but the
Power LED is off.
The power cord is not connected at both ends. Plug the
power cord in at the hub and the power source.
The power cord is plugged in, but
the Power LED is off.
– The line voltage is inadequate. Reactivate or adjust line
voltage.
– The power cord is bad. Replace the power cord.
– The hub is faulty. Replace the hub.
72
If the Power LED Is Off
Download from Www.Somanuals.com. All Manuals Search And Download.
If the Hub Fault LED Stays on After Self-Test
If the hub Fault LED stays on after the self-test is complete, find the symptom that best
describes the situation, then attempt the solution. When more than one solution is possible,
the most likely one is listed first.
Symptom
Cause/Solution
The host can access devices, but
the hub Fault LED stays on after
self-test.
– One or more fans are faulty. Replace the fan module.
Although the module will continue to run with two fans, a
full complement of fans ensures system and data integrity.
– The hub is experiencing an internal temperature or
memory fault. Replace the hub.
The host cannot access devices,
and the Fault LED stays on after
self-test.
– The hub is faulty. Replace the hub.
If the Hub Fault LED Stays on After Self-Test
73
Download from Www.Somanuals.com. All Manuals Search And Download.
If a Fan Is Not Operating
If one or more fans stop, find the symptom that best describes the situation, then attempt
the solution. When more than one solution is possible, the most likely one is listed first.
Symptom
Cause/Solution
The host can access devices, the
Fault LED stays on after self-test,
and one or more fans have
stopped.
– One or more of the fans are blocked or obstructed. Verify
that the fans are not blocked or obstructed.
– The fan module is not firmly seated. Reinstall the fan
module.
– The fans are faulty. Replace the fan module.
74
If a Fan Is Not Operating
Download from Www.Somanuals.com. All Manuals Search And Download.
If a Device Is Unlisted/UNCLAIMED in ioscan or
Not Displayed in SCSI Adapters Window
If ioscan (HP-UX server) does not list a device connected to the hub or shows the status of
the device as UNCLAIMED or NO H/W, or if the SCSI Adapters window (HP NetServer)
does not display a device connected to the hub, the problem may be with the device, the
hub, the host, or the connections between them. Find the combination of symptoms below
that best describes the situation, then attempt the solution. When more than one solution is
possible, the most likely is listed first. The hub does not appear in ioscan output or the
SCSI Adapters window because it does not have a hardware address.
Symptom
Cause/Solution
The Port LED for the host or the
device is off, and ioscan does not
list the device.
– The connection between the device or host and the
hub is faulty. See If a Port LED Is Off on page 76.
– The host’s FC adapter is faulty. Replace the adapter.
– The FC device is faulty. Replace the device.
The Port LED is on, and ioscan
does not list the device.
There is a duplicate hardware address on the FC-AL
loop. Verify that all devices on the loop have unique IDs,
then reset the hub.
The Port LED is on, and ioscan
Class is “UNKNOWN.”
The software driver is missing on the host. Replace the
device driver file.
The Port LED is on, and ioscan
shows the S/W State as
“UNCLAIMED” or “NO H/W.”
– The device has a duplicate address with another
device on the loop. Change the address of one of the
devices to a unique address. (The device may need to be
powered off and on to reset the address.)
– The software driver for the device is incorrect on the
host. Replace the device driver file on the system.
– The device is faulty. Troubleshoot the device using the
instructions that came with the device. Be sure to check
the fiber optic transmit or receiving port on the device.
The hub Fault LED is on, and
ioscan does not list the device.
The hub is faulty. Replace the hub.
If a Device Is Unlisted/UNCLAIMED in ioscan or Not Displayed in SCSI Adapters Window
75
Download from Www.Somanuals.com. All Manuals Search And Download.
If a Port LED Is Off
If a Port LED is off where a cable is connected, find the symptom that best describes the
situation, then attempt the solution. When more than one solution is possible, the most
likely one is listed first.
If all port LEDs are off where cables are connected, see If Firmware Upgrade Appears to
Fail on page 79.
Symptom
Cause/Solution
The host cannot access the
device, and the Port LED is off.
– The port is bypassed in Fibre Channel Manager. If you are
using Fibre Channel Manager to manage the hub, verify
that the port in question is enabled. (See the HP Fibre
Channel Manager User Manual for more information.)
– The device is faulty or offline. Verify that the device is
turned on and has successfully completed its self-test.
– The device is incompatible with the hub. Replace with
a non-OFC, short-wave, 1063-Mbps FC-AL device.
The device is good, and the Port
LED comes on when a loopback
cable is connected to the hub
port.
– The cable is incompatible with the hub. Replace the cable
with a 50 or 62.5-micron multimode fiber optic cable.
– A short-wave port is connected to the long-wave port on
another hub. When cascading hubs, only connect long-
wave ports to long-wave ports and short-wave ports to
short-wave ports. Reconnect the hubs accordingly.
– The connector is dirty. Clean both ends of the cable with
high purity alcohol and wipe with a soft, lint-free cloth (see
chapter 5, Maintenance and Replacement).
– The cable is bent or broken. Replace the cable.
The Port LED remains off when a
loopback cable is connected to
the hub port.
– The hub port is dirty. Try cleaning the port by gently
blowing with clean, dry compressed air (see chapter 5,
Maintenance and Replacement). Reattach the loopback
cable and see if the Port LED is on.
– The hub port is faulty. Replace the hub.
76
If a Port LED Is Off
Download from Www.Somanuals.com. All Manuals Search And Download.
If a Port LED Is On When It Should Be Off
If a Port LED is on when no active device is attached, find the symptom that best fits the
situation, then attempt the solution. When more than one solution is possible, the most
likely one is listed first.
Symptom
Cause/Solution
The cable has been
The cable is still connected to a functional device. Check
the Fibre Channel mass storage device map to verify that
the device is connected to the port. Also look for a Port LED
that is off but should be on. Change the connections or
change the map as needed.
disconnected at the device or is
connected to an inactive device,
and the Port LED is on.
Port LED stays on after the cable
is disconnected from the port.
The hub is faulty. Replace the hub.
If a Port LED Is On When It Should Be Off
77
Download from Www.Somanuals.com. All Manuals Search And Download.
If the Management Server Cannot Ping the Hub
If you cannot ping the hub from the management server (host) where Fibre Channel
Manager is or will be installed, find the symptom that best fits the situation, then attempt
the solution. When more than one solution is possible, the most likely one is listed first.
Symptom
Cause/Solution
You cannot ping the hub and the
hub’s 10Base-T port LED is off.
The ethernet cable is not connected properly. Verify that
the ethernet cable is securely connected to the hub and the
management server.
The ethernet cable is faulty. Connect another ethernet
cable between the management server and hub.
You cannot ping the hub and the
hub’s 10Base-T port LED is on.
The IP address used to ping the hub is incorrect. Verify
that you typed the correct IP address when pinging the hub.
One or more of the hub’s addresses are incorrect.
Display the hub’s serial interface as described in chapter 3,
RS-232 Interface Functions. Verify that the hub’s IP,
subnetworking mask, and default gateway addresses are
correct.
If you do not enter 5. Save Network Setup changes and
reboot, the addresses you enter are not saved.
78
If the Management Server Cannot Ping the Hub
Download from Www.Somanuals.com. All Manuals Search And Download.
If Firmware Upgrade Appears to Fail
The hub management menus and Boot menu require a serial interface through the RS-232
port of the hub.
Symptom
Cause/Solution
– During firmware upgrade, the
following message appears
The hub device agent code and hub controller firmware are
not compatible. Incompatibility can occur when:
every 1 minute and 45 seconds:
– The device agent code was installed in the incorrect
order.
Hub-Controller version:
03.06 is now loaded
into RAM
– Firmware transfer was interrupted during the update
procedure.
– Only one firmware file was updated.
– After firmware upgrade, ‘Hub
Controller Version” and “Status
of Hub Controller self-test” are
blank on Main menu.
The hub controller firmware must be updated before
updating the hub device code. Both files must be updated.
Reinstall the prior version of the firmware as described in
the following section. Then follow the update procedures
provided in Updating the Hub Firmware on page 48.
– All port LEDs are off.
– The hub is inoperable.
The terminal screen does not
display a prompt.
The serial port is not connected. Verify that the serial
cable is connected to the correct ports.
The cable is not a null-modem cable. Verify that the
cable connected to the RS-232 port is a null-modem cable.
The terminal or terminal emulator is not configured
correctly. Verify that the terminal or terminal emulator is
configured as described on page 46.
“pROBE+>” appears instead of
the Main menu.
The hub firmware is experiencing temporary difficulty.
Reset the hub, and verify that the Main menu appears.
If Firmware Upgrade Appears to Fail
79
Download from Www.Somanuals.com. All Manuals Search And Download.
Recovering from Failed Firmware Upgrade
To recover from firmware upgrade difficulties, you must first reinstall the previous
versions of firmware, then upgrade to the new version of firmware. The previous versions
of firmware were included in the compressed file you downloaded from the Hewlett-
Packard Software Depot (http://www.software.hp.com).
1. Connect a serial cable to the hub RS-232 port and configure the terminal emulator (see
Setting Up a Connection to a PC on page 45).
2. Press the Reset button on the front panel of the hub.
The terminal emulator screen begins to display the status of the hub. To reboot, you
must interrupt the status display to go to the Boot menu.
3. Wait for the following message:
Press Enter key for Boot Menu, Agent boot in 6 seconds.
4. Immediately press <ENTER> to display the Boot menu:
Boot menu V01.04
1. Download and update Device Agent code
2. Download and update Hub-Controller code
3. Reset hub and run self test
4. Start Normal Hub operation
80
If Firmware Upgrade Appears to Fail
Download from Www.Somanuals.com. All Manuals Search And Download.
Reinstalling the Hub Device Agent Code
1. From the Boot menu, enter 1 to update the device agent code. A prompt appears for you
to begin file transfer; for example:
Ready to download Device Agent code to RAM
Start ASCII file (S-record format) transfer now
<Refer to terminal emulator user manual for instructions>
Press control-C at any time to cancel
2. From the terminal emulator application, use the transfer option to send a text file. The
appropriate file was previously downloaded as a compressed file from the Hewlett-
Packard Software Depot (http://www.software.hp.com).
For model S10 short-wave hubs, send the following file:
IFCH3719.FRM
For model L10 long-wave hubs, send the following file:
IFCH3720.FRM
The screen is filled with rows of progress indicator dots as the file is transferred; for
example:
...................................................................
...................................................................
...................................................................
.....................................................
The transfer process can take 10 to 40 minutes.
When the file transfer has been completed, status messages and a transfer prompt
appear; for example:
Done, memory range [$00001000:$0005B666]
Ready to transfer Device Agent code from RAM to FLASH
Note, once started, this step must not be interrupted
Press Enter to start, control-C to cancel
The values displayed for memory range represent low-level diagnostics. The values
displayed in the status message can be different from the values shown here.
If Firmware Upgrade Appears to Fail
81
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Press <ENTER>. The screen displays status messages; for example:
FLASH programming will take about 40 seconds
FLASH pgm:[$001000:$101000)->[$800000:$900000) >
Caution
Do not interrupt the display or press any keys during this process.
After about 40 seconds, the display continues.
When FLASH programming is completed, the checksum appears; for example:
FLASH programming will take about 40 seconds
FLASH pgm:[$001000:$101000)->[$800000:$900000) > complete, no errors
New FLASH checksum = 0x12FC
The value displayed can be different from the example shown here. Then the Boot
menu appears again.
Reinstalling the Hub Controller Firmware
1. From the Boot menu, enter 2 to update the hub controller firmware.
2. From the terminal emulator application, select the transfer option to send a text file.
The screen displays status messages and progress indicators; for example:
Ready to download Hub-Controller code to RAM
Start ASCII file (S-record format) transfer now
<Refer to terminal emulator user manual for instructions>
Press control-C at any time to cancel
3. Send the following file you previously downloaded from the Hewlett-Packard Software
Depot:
IFCH3718.FRM
Several rows of dots appear to indicate download progress; for example:
...................................................................
...................................................................
...................................................................
...................................
82
If Firmware Upgrade Appears to Fail
Download from Www.Somanuals.com. All Manuals Search And Download.
After a few minutes, the transfer prompt appears; for example:
Done, memory range [$00001000:$00004FFF]
Ready to transfer Hub-Controller code from RAM to FLASH
Note, once started, this step must not be interrupted
Press Enter to start, control-C to cancel
The values displayed for memory range represent low-level diagnostics; the values
displayed in the status message can be different from the values shown here.
4. Press <ENTER>. Additional progress indicators and status messages appear; for
example:
--+
$..................................................................
.........
************************
The hub is automatically rebooted and additional messages appear:
Rebooting to make sure download was successful...
DRAM test
(this will take about 10 seconds) > passed
SEEPROM test (this will take about 1 second ) > passed
FLASH checksum (this will take about 2 seconds) > passed
Press Enter key for Boot Menu, Agent boot in 6 seconds
Then the Main menu appears.
Fibre Channel Hub Model Number:
Device Agent Version:
HP3724A
02.04
Hub Controller Version:
02.02
Agent Boot PROM Version:
01.04
Status of Device Agent self-test:
Status of Hub Controller self-test:
passed
passed
1. Reset hub and run self-test
2. Set Networking parameters
5. Verify that the Device Agent and Hub Controller versions you reinstalled appear in the
Main menu.
6. See Updating the Hub Firmware on page 48 to upgrade to the new firmware versions.
If Firmware Upgrade Appears to Fail
83
Download from Www.Somanuals.com. All Manuals Search And Download.
84
If Firmware Upgrade Appears to Fail
Download from Www.Somanuals.com. All Manuals Search And Download.
5
MAINTENANCE AND REPLACEMENT
Introduction
Maintenance
Replacing the Fan Module
85
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
This chapter explains how to maintain the hub and replace the fan module. The fan module
is the only replaceable part on the hub. To identify the source of a problem, see chapter 4,
Troubleshooting.
WARNING
Do not attempt to open the hub chassis. Uninsulated parts inside the
chassis constitute a hazard.
86
Introduction
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
Good system performance requires clean port optics and cable ferrules to avoid
obstructing the optical path. The following preventive maintenance will protect the hub for
longer use.
•
•
•
•
Vacuum to remove dust.
Leave the FC port covers on unused FC ports.
Replace the fan module every three years.
Avoid dropping fiber optic cable ends. This can cause internal glass fractures and
intermittent signals.
•
Keep unused cable ends covered to avoid contaminant-obscured or attenuated light
signals.
•
•
Never insert foreign objects into the optical transmit and receive ports.
Avoid bending fiber cables over more than a 3-cm bend radius.
When a faulty connection is suspected, blowing clean compressed air on the FC port and
cable end often is sufficient to remove dirt particles. Cleaning the connectors with
methanol on a lint-free cloth is also effective. Alcohols that can be used include methyl,
isopropyl, and isobutyl. Other acceptable substances for cleaning fiber optics are hexane
and heptane aliphatics, soap solution, and naphtha.
Caution
DO NOT use partially halogenated hydrocarbons, ketones, acetone,
chloroform, ethyl acetate, methylene dichloride, phenol, methylene chloride, or
N-methylpyrolldone to clean the connectors.
Maintenance
87
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing the Fan Module
The three fans in the fan module operate in parallel. If one fan fails, the other two will
continue to operate. However, it is important to replace the fan module immediately.
Replace the fan module at least once every three years.
You will need the following tools:
•
•
Standard Phillips screwdriver
Fan module (A3724-60002)
WARNING
The power cord is the main disconnect for this product. To protect
against hazard, always unplug the AC power cord before removing
the fan module.
1. Relocate or power off devices connected to the hub as needed to prepare for powering
off the hub.
2. Unplug the power cord from the hub.
3. Using a standard Phillips screwdriver, remove the four screws that secure the fan
module. Sheet metal marks indicate the location of the screws on the top and sides of
the hub.
88
Replacing the Fan Module
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 21 Removing the Fan Module
4. Remove the fan module.
5. To insert the new fan module, line up the tabs on the bottom of the fan with the tab
openings on the hub (see Figure 22 for positioning). Push the fan module into the hub.
Replacing the Fan Module
89
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 22 Replacing the Fan Module
6. Fasten the four screws to secure the fan module.
7. Plug the power cord into the hub.
The hub powers on and runs the self-test. When the self-test is complete, the Power
LED should remain lit and the Fault LED should be off.
90
Replacing the Fan Module
Download from Www.Somanuals.com. All Manuals Search And Download.
6
REFERENCE
Standard Configurations
Configuration Options
Replacement Parts
Operating Requirements
Environmental Specifications
Physical Characteristics
Reference Documents
Regulatory Statements
Laser Safety
91
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Configurations
Model S10 short-wave and model L10 long-wave hubs are available in standalone and
factory-racked configurations (Figure 23 and Figure 24).
The short-wave or long-wave standalone models can be ordered with a customer-
installable rackmount option for adding the hub to an existing cabinet.
Table 3 HP SureStore E Hub Product Numbers
Product Number
Description
HPA3724A
Standalone short-wave hub
Factory-racked short-wave hub
Standalone long-wave hub
Factory-racked long-wave hub
HP A3724AZ
HP A4839A
HP A4839AZ
92
Standard Configurations
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 23 HP SureStore E Hub, Standalone
HP SureStore E Hub
Models S10 and L10
Service and User Manual
hub
power cord
Installed FC
port covers
rubber feet
FC-AL
loopback cable
NOTE: The long-wave hub
includes an additional loopback
cable for the long-wave port.
Standard Configurations
93
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 24 HP SureStore E Hub, Factory-Racked
HP SureStore E Hub
Models S10 and L10
Service and User Manual
hub
HP EIA rack
FC-AL loopback cable
NOTE: The model L10 long-wave hub
includes an additional loopback
cable for the long-wave port.
installed FC
port covers
94
Standard Configurations
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuration Options
Model S10 short-wave and model L10 long-wave hubs can be ordered with the following
options:
•
A customer-installable rackmount kit for adding the hub to an existing cabinet (Table 4
and Figure 25)
•
Cables of various lengths
Table 4 HP SureStoreE Hub Configuration Options
Option
Description
001
AFY
0Z5
0Z6
Includes one rackmount kit
Includes 16-m Fibre Channel cable
Includes 50-m Fibre Channel cable
Includes 100-m Fibre Channel cable
Fibre Channel Manager is the hub’s software management tool. This tool allows you to
remotely manage and monitor the health of the hub. Visit the Hewlett-Packard Software
Depot (http://www.software.hp.com) for more information or to download Fibre Channel
Manager at no charge.
Configuration Options
95
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 25 Model S10 or L10 Option 001 Hub Rackmount Kit
FC-AL Hub
Rackmount Kit
Installation
Guide
PDU cable
10-32x.625 rail
screws
plenum shroud
rails
sheet metal nuts
nylon retainers
M3x.50 machine screws
mounting ear brackets
96
Configuration Options
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacement Parts
External parts on the hub are replaceable. The following figure and tables provide order
numbers for replaceable parts. An HP sales representative can help you obtain the part you
need.
Figure 26 HP SureStore E Hub Replaceable Parts
plenum shroud
(A3724-60004)
fan module
(A3724-60002)
rails (A3724-00002)
M3x.5 machine screw
(0515-0914)
nylon retainer
(A3724-0004)
sheet metal nuts
(0590-0804)
10-32x.625 rail screws
(2680-0323)
hub (models S10 or L10)
mounting ear bracket (A3724-00001)
M3x.5 machine screws (0515-0914)
loopback cable:
short-wave (1005-0624)
long-wave (A4839-63001)
Replacement Parts
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 5 HP SureStore E Hub Replaceable Parts and Service Part Numbers
Replaceable Part
Service Part Number
Mounting ear brackets
Rails
A3724-00001
A3724-00002
A3724-00004
A3724-60002
A3724-60004
A3724-62001
A3724-69001
A4839-69001
A4839-63001
1005-0624
Nylon retainers
Fan module
Plenum shroud
Rackmount kit
Exchange short-wave hub
Exchange long-wave hub
FC-AL long-wave loopback cable
FC-AL short-wave loopback cable
M3 x .50 machine screws
Sheet metal nuts
0515-0914
0590-0804
10-32 x .625 machine screws
2680-0323
Table 6 Multimode Fiber Optic Cable Part Numbers
Cable Description*
Customer Order Number
Service Part Number
16 m, 50 micron, multimode fiber optic
50 m, 50 micron, multimode fiber optic
100 m, 50 micron, multimode fiber optic
A3531A
A3735A
A3736A
1005-0586
1005-0365
1005-0366
*
Hewlett-Packard has tested the AMP single-mode #504655-1 SC Connector and Fujikura
Fibre Channel connector with lower metal content (as opposed to the connector with
standard metal content) for compliance to FCC Article 15 for RFI in Class A environments.
For other multi-mode lengths and specifications for single-mode cables, see Cable Plant
Specifications on page 101.
98
Replacement Parts
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7 Power Cord Part Numbers
Description
Service Part Number
Argentina
Australia
8120-6869
8120-1369
8120-6980
8120-2956
8120-1689
8120-8325
8120-4753
8120-4211
8120-2104
8120-1351
8120-1751
8120-3996
Chile
Denmark
Europe
Israel
Japan
South Africa and India
Switzerland
United Kingdom
USA 120V
USA 240V
Replacement Parts
99
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Requirements
Software and Operating System Requirements
The hub does not require drivers or specific versions of operating systems. However,
systems and FC-AL devices that can connect to the hub do have driver and operating
system requirements. Contact an HP sales representative for information on hardware and
software requirements for the FC-AL devices you plan to connect to the hub.
Physical and Cabling Requirements
Note
For short-wave ports, SC Connectors must be AMP multimode #504657-1 or
equivalent to meet FCC Part 15 standards. For long-wave ports, SC Connectors
must be AMP single-mode #504655-1 or equivalent to meet FCC Part 15
standards. Cable Plant Specifications on page 101 lists more requirements.
Model S10 Short-Wave Hub
The short-wave hub supports 10 non-OFC, short-wave FC-AL connections. In arbitrated
loop topology, data rates and wavelength between ports must be the same. The short-wave
hub supports only gigabit short-wave to gigabit short-wave connections using fiber cables.
For the short-wave hub, Hewlett-Packard recommends 50-micron multimode fiber cable
for new installations but also supports 62.5-micron multimode fiber cable with SC-style
connectors in existing installations. Installations can mix 50-micron and 62.5-micron
cables.
Model L10 Long-Wave Hub
The long-wave hub supports short-wave gigabit to short-wave gigabit connections from
ports 1 through 9 using fiber cables. The long-wave hub also supports a long-wave hub to
long-wave hub connection from the long-wave port.
100
Operating Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
For the long-wave port, Hewlett-Packard recommends 9-micron single-mode fiber
cable.
For ports 1 through 9, Hewlett-Packard recommends 50-micron multimode fiber cable
for new installations but also supports 62.5-micron multimode fiber cable with SC-style
connectors in existing installations.
Cable Plant Specifications
The cable plant includes losses of the fiber and splices and connectors (excluding those at
the ends of the link that are accounted for in the transmitter and receiver specifications).
Table 8 Cable Plant Specifications: Single-Mode (2 km–10 km, 100 MB/sec)
Specification
Units
Value
Fiber type
Single-mode; step index
Fiber core
micron
MHz
Ps/nm
dB
9 (nominal)
Not applicable
< 35
Fiber Bandwidth (1 km)
Fiber Dispersion
Return loss of cable plant with receiver connected
Return loss of each individual connector or splice
Cable plant loss
> 12
dB
> 26
dB
< 6*
*
HP suggests that the loss of a new single-mode cable plant be limited to 6dB or lower in
order to maximize the probability that the cable plant will permit 10- km operation with
the majority of long-wave hubs (HP-UX servers only). Larger losses are permissible if the
receiver power is greater than -17dBm. For new installations, HP recommends that the
single-mode fiber be low-loss fiber equivalent to Corning’s premium grade of their single-
mode SMF-28 cable with loss of 0.35 dB/km or lower in order to more easily attain the
required signal power at the receiver in spite of losses due to connectors and splices.
Operating Requirements
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 9 Cable Plant Specifications: 50-Micron Multimode (500 m, 100 MB/sec)
Non-OFC Operation
Specification
Units
Value
Fiber type
Multimode; graded index
50 (nominal)
> 500 @ 850nm
Not applicable
> 12
Fiber core
micron
MHz
Ps/nm
dB
Fiber Bandwidth (1 km)
Fiber Dispersion
Return loss of cable plant with receiver connected
Return loss of each individual connector or splice
Cable plant loss
dB
> 26
dB
< 6
Table 10 Cable Plant Specifications: 62.5-Micron Multimode (175 m, 100 MB/sec)
Non-OFC Operation
Specification
Units
Value
Fiber type
Multimode; graded index
62.5 (nominal)
> 160 @ 850nm
Not applicable
> 12
Fiber core
micron
MHz
Ps/nm
dB
Fiber Bandwidth (1 km)
Fiber Dispersion
Return loss of cable plant with receiver connected
Return loss of each individual connector or splice
Cable plant loss
dB
> 26
dB
< 6
102
Operating Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Hardware
Model S10 Short-Wave Hub
•
•
Multimode 62.5-micron (175-meter) or 50-micron (500-meter) fiber cables
HP-UX servers and HP NetServers and other FC-AL devices equipped with a compatible
1063-Mbps, short-wave, non-OFC adapter. Contact an HP sales representative for
details on specific devices and required versions of operating systems.
•
•
RS-232 configuration and diagnostics
10Base-T port for ethernet connection to HP-UX server for hub management tool (Fibre
Channel Manager). The server must be running HP-UX 10.20 or 11.0.
Model L10 Long-Wave Hub
•
Ports 1-9: Multimode 62.5-micron (175-meter) or 50-micron (500-meter) fiber cables.
HP-UX servers and HP NetServers and other FC-AL devices equipped with a compatible
1063-Mbps, short-wave, non-OFC adapter. Contact an HP sales representative for
details on specific devices and required versions of operating systems.
•
Long-Wave Port: Single-mode 9-micron (3-km) fiber cables. HP long-wave, hub (model
L10) equipped with a compatible long-wave port.
•
•
RS-232 configuration and diagnostics
10Base-T port for ethernet connection to HP-UX server for hub management tool (Fibre
Channel Manager). The server must be running HP-UX 10.20 or 11.0.
Operating Requirements
103
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Distances
Table 11 summarizes the supported distances between a host and devices connected to
short-wave ports with 50-micron and 62.5-micron cables and long-wave ports with
9-micron cables. The table does not include combinations of mixed cable lengths.
Table 11 Supported Cable Distances
1
1
2
Short-Wave
50 micron
Short-Wave
Long-Wave
9 micron
62.5 micron
(multimode)
Connection
(multimode)
(single-mode)
Host to Hub
Hub to Hub
500 m
500 m
175 m
175 m
Not supported
3
3 km
Hub to Device
Total
500 m
175 m
525 m
Not supported
Varies
1500 m
1
2
3
Ports 1-10 on short-wave hub; ports 1-9 on long-wave hub
Long-wave port on long-wave hub
Under certain conditions, single-mode 9-micron cables are supported at
distances up to 10 km (see page 105 for more information). The 10-km
capability is supported only for long-wave hubs connected to HP-UX servers.
Model S10 Short-Wave Hub
Note
Stated distances assume 50-micron multimode cable.
The short-wave hub supports distances up to 500 meters between a server host and the
hub, between a hub port and a connected FC-AL device, and between two short-wave hubs.
The maximum distance between a host server and FC-AL devices connected to cascaded
short-wave hubs is 1500 meters.
104
Operating Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Model L10 Long-Wave Hub
Note
Stated distances assume 9-micron single-mode cable for the long-wave port and
50-micron multimode cable for the short-wave ports.
For ports 1 through 9, the long-wave hub supports distances of 500 meters between the
port and a connected FC-AL device. For the long-wave port, the long-wave hub supports
distances up to 3 kilometers between two long-wave hubs. Under certain conditions,
cascaded long-wave hubs are supported at distances up to 10 kilometers. The 10-km
capability is supported only for long-wave hubs connected to HP-UX servers.
To verify 10-km capability for the long-wave hub over an existing cable plant:
The received average optical power of the long-wave port on both long-wave hubs must be
higher (more positive) than -17 dBm in order for the long-wave hubs to support cascade
distances of up to 10 km. Use an optical power meter that measures average optical power
at a wavelength of 1300 nm in dBm units (for example, the Fotec Model 712A Power Meter
with Model A262 SC connector adapter).
To verify the long-wave port’s received average optical power, do the following:
1. Power on both long-wave hubs and connect the long-wave ports with the 10-km single-
mode cable.
2. Turn the optical power meter on. The meter performs a self-test.
3. If necessary, set the meter’s wavelength to 1300 nm and measuring units to dBm.
4. Disconnect the Fibre Channel cable from the long-wave port of one of the two hubs.
5. Determine which connector of the Fibre Channel cable is the transmitter. Connect one
plug of the Fibre Channel cable into the SC receptacle of the meter. If the meter does
not indicate a signal, connect the other plug of the Fibre Channel cable.
6. Verify that the reading on the meter is higher (more positive) than -17 dBm and lower
than -3 dBm.
7. Reconnect the Fibre Channel cable to the long-wave port.
8. Repeat steps 4 through 7 with the long-wave port of the second long-wave hub.
Operating Requirements
105
Download from Www.Somanuals.com. All Manuals Search And Download.
If both ends of the Fibre Channel cable are between the limits listed in step 5, the two
long-wave hub’s are verified for cascading up to 10 km using this cable plant. If the meter
readings are not within range, verify that the Fibre Channel cable is securely connected to
the hub’s long-wave port. Also verify, that the cable connectors are clean by wiping them
with a lint-free cloth dampened with reagent grade isopropyl alcohol and blowing the
connectors dry with clean, compressed air.
106
Operating Requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Environmental Specifications
Table 12 Environmental Specifications for Model S10 Short-Wave and
Model L10 Long-Wave Hubs
Environment
Limitations
Temperature:
– operating
– nonoperating
+5 to +40° C
-40 to +70° C
Humidity:
– operating
– nonoperating
20 to 80% maximum relative humidity
5 to 90% relative humidity at 65° C
Altitude:
– operating
– nonoperating
0 to 10,000 ft. at operating temperature
10,000 to 15,000 ft. at nonoperating temperature
Power Line
voltage range ±10%
and frequency
100 VAC autoranging, 1.2 Amps, 50 to 60 Hz
240 VAC autoranging, .6 Amps, 50 to 60 Hz
Heat Dissipation
650 BTU/hr
165 kcal/hr
Environmental Specifications
107
Download from Www.Somanuals.com. All Manuals Search And Download.
Physical Characteristics of Standalone Hub
Table 13 Physical Characteristics of Model S10 Short-Wave and Model L10 Long-Wave Hubs
Packaged Product
Physical
Dimensions
Product Alone
with 16-meter cable
with 50/100-meter cable
Height
Width
Depth
Weight
1.7 in. (43 mm)
17.3 in. (439 mm)
14.0 in. (356 mm)
8 lbs.
13.0 in. (330 mm)
27.5 in. (699 mm)
22.5 in. (572 mm)
30 lbs.
22.0 in. (559 mm)
30.5 in. (775 mm)
21.0 in. (533 mm)
32/34 lbs.
108
Physical Characteristics of Standalone Hub
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference Documents
Installation Documents
•
•
•
Hewlett-Packard SureStoreE Hub Models S10 and L10 Service and User Manual
(A3724-90006)
Hewlett-Packard Fibre Channel Mass Storage Adapter Service and User Manual
(A3636-90002)
Configuring HP-UX for Peripherals (HP9000) (B2355-90053)
Administration/Troubleshooting Documents
•
•
•
Hewlett-Packard Fibre Channel Manager User Manual
HP-UX System Administration Tasks Manual (B2355-90079)
Support Tools Manager User’s Manual HP 9000 Series 700 and Series 800 PA-RISC
Computer Systems (5961-1612)
Fibre Channel Technology Documents
•
•
•
Fibre Channel: Connection-to-the-Future (ISBN 1-878707-19-1)
The Fibre Channel Consultant: Arbitrated Loop (ISBN 0-931836-82-4)
What is Fibre Channel? (ISBN 0-9637439-1-0)
Reference Documents
109
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Statements
A. FCC Statement (For U.S.A. Only)
The Federal Communications Commission (in 47 CFR 15.105) has specified that the
following notice be brought to the attention of the users of this product.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense. The end user of this product should be aware
that any changes or modifications made to this equipment without the approval of Hewlett-
Packard could result in the product not meeting the Class A limits, in which case the FCC
could void the user's authority to operate the equipment.
B. IEC Statement (Worldwide)
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
C. Spécification ATI Classe A (France)
DECLARATION D’INSTALLATION ET DE MISE EN EXPLOITATION d’un matériel de
traitement de l’information (ATI), classé A en fonction des niveaux de perturbations
radioélectriques émis, définis dans la norme européenne EN 55022 concernant la
Compatibilité Electromagnétique.
Cher Client,
Conformément à la Réglementation Française en vigueur l’installation ou le transfert
110
Regulatory Statements
Download from Www.Somanuals.com. All Manuals Search And Download.
d’installation, et l’exploitation de cet appareil de classe A, doivent faire l’objet d’une
déclaration (en deux exemplaires) simultanément auprès des services suivants:
–
–
Comité de Coordination des Télécommunications 20, avenue de Ségur - 75700 PARIS
Préfecture du département du lieu d’exploitation
Le formulaire à utiliser est disponible auprès des préfectures.
La déclaration doit être faite dans les 30 jours suivant la mise en exploitation.
Le non respect de cette obligation peut être sanctionné par les peines prévues au code
des Postes et Télécommunications et celles indiquées dans la loi du 31 mai 1993
susvisée.
Arrêté du 27 Mars 1993, publié au J.O. du 28 Mars - ATI
D. Product Noise Declaration (Germany)
Acoustic Noise Emissions
LpA: 45 dB
At bystander position per ISO 7779.
All data are the results from type tests of the product configuration having the highest
acoustic emissions.
Geräuschemission
LpA: 45 dB
Am fiktiven Arbeitsplatz nach DIN 45635 T. 19.
Die Daten sind die Ergebnisse von Typprüfungen an Gerätekonfigurationen mit den
höchsten Geräuschemissionen:
Regulatory Statements
111
Download from Www.Somanuals.com. All Manuals Search And Download.
E. VCCI Statement (Japan)
112
Regulatory Statements
Download from Www.Somanuals.com. All Manuals Search And Download.
Laser Safety
A. Certification and Classification Information
This product contains a laser internal to the Optical Link Module (OLM) for connection to
the Fibre communications port.
In the USA, all models of the OLM are certified as Class 1 laser product and conform to the
requirements contained in the Department of Health and Human Services (DHHS)
regulation 21 CFR Subchapter J. The certification is indicated by a label located on the
plastic OLM housing.
Outside the USA, all models of the OLM are certified as Class 1 laser components that
conform to the requirements contained in the International Electrotechnical Commission
(IEC) standard 825 (1994)and Amendment 1 (1990) along with the CENELEC (European
Committee for Electrotechnical Standardization) European Normalization Standard EN
60825 (1992).
Certifications include one or more of the following: Recognized Component and Certified
for Canada by Underwriters Laboratories, Certified by TUV (Germany).
The following figure shows the Class 1 information label specified in IEC 825 and
CENELEC HD 482 51.
Class 1 Laser Product
Laser Klasse 1
Luckan 1 Laserlaite
Laser Safety
113
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Product Information
Each communications port consists of a transmitter and receiver optical subassembly. The
transmitter subassembly contains internally a semiconductor laser diode in the wavelength
range of 780 to 1300 nanometers. In the event of a break anywhere in the fibre path, the
OLM control system prevents laser emissions from exceeding Class 1 levels.
Class 1 laser products are not considered hazardous.
WARNING
There are no user maintenance or service operations or adjustments
to be performed on any OLM model.
C. Usage Restrictions
Failure to comply with these usage restrictions may result in incorrect operation of the
system and points of access may emit laser radiation above the Class 1 limits established
by the IEC and U.S. DHHS.
D. Laser Safety (Finland) LASERTURVALLISUUS
LASERTURVALLISUUS
LUOKAN 1 LASERLAITE
KLASS 1 LASER APPARAT
Fibre Channel 1063 MBaud Optical Link -kortille on asennettu optista tiedonsiirtoa varten
laserlähetin, joka lähettää signaalit siihen kytketyn optisen kuidun kautta.
Normaalissa toimintatilassa lähetin on käyttäjälle turvallinen luokan 1 laserlaite, eikä
käyttäjä voi altistua sen lähettämälle säteilylle. Optisen lähetinmoduulin turvallisuusluokka
on määritetty standardin EN 60825 (1991) mukaisesti.
Optisessa lähetinmoduulissa ei ole huollettavia kohteita eikä sen tehtaalla tehtyjä säätöjä
tule muuttaa. Lähetinmoduuli on myös suunniteltu siten, että turvallisuusluokan 1
säteilyrajat eivät ylity, vaikka lähetinmoduuliin kytketty optinen kuitu rikkoutuu tai
kytketään irti lähettimen toimiessa.
114
Laser Safety
Download from Www.Somanuals.com. All Manuals Search And Download.
Lähetinmoduulin turvallisen toiminnan varmistamiseksi on noudatettava tarkoin sen
asentamisesta ja toiseen vastaanottavaan laitteistoon kytkemisestä annettuja ohjeita.
Tiedot optisessa lähetinmoduulissa käytettävien laserdiodien säteilyominaisuuksista:
Aallonpituus
(SW) 780 - 850 nm
(LW) 1300 nm
Laser Safety
115
Download from Www.Somanuals.com. All Manuals Search And Download.
Declaration of Conformity
116
Laser Safety
Download from Www.Somanuals.com. All Manuals Search And Download.
GLOSSARY
Arbitrated Loop
See Fibre Channel - Arbitrated Loop.
Child Hub
The HP SureStore E short-wave and long-wave hubs support a cascaded topology. In a
cascaded hub topology, the child hub is the hub that is not connected to the LAN
(ethernet). HP SureStore E hubs are configured as a parent or child hub through their
RS-232 interface.
Device
See FC-AL Device.
Enclosure
The box, rack, or set of boxes containing one or more devices. It may provide the
powering, cooling, mechanical support, and external electronic interfaces for those
devices.
FC-AL Device
A device that uses Fibre Channel Arbitrated Loop, which consists of one or more
NL_Ports.
FC-AL Port
The port on the hub that provides connection between the FC-AL adapter and the FC-
AL link.
Fiber
The fiber optic cable made from thin strands of glass through which data in the form of
light pulses is transmitted (LASER, LED). It is used for high-speed transmission over
medium to long distances.
117
Download from Www.Somanuals.com. All Manuals Search And Download.
Fibre Channel
Logically, Fibre Channel is a bidirectional, full-duplex, point-to-point, serial data
channel structured for high performance capability. Physically, the Fibre Channel is an
interconnection of multiple communication ports, called NL_Ports, interconnected by a
switching network, called a fabric, a point-to-point link or an arbitrated loop. Fibre
Channel is a generalized transport mechanism that has no protocol of its own or native
input/output command set, but can transport any existing Upper Level Protocols
(ULPs) such as SCSI and IPI at speeds of 100 Mbytes/sec over distances of up to 10
kilometers over optical links. Fibre Channel can interconnect two devices in a point-to-
point topology, from two to 126 devices in an arbitrated loop, and up to 224 devices in a
fabric switched topology.
Fibre Channel Arbitrated Loop (FC-AL)
One of three existing Fibre Channel topologies in which two to 126 devices are
interconnected serially in a single loop circuit without hubs and switches.
Communication is managed using an arbitration process in which the lowest port
address has the highest priority for communicating. The arbitrated loop topology
supports all classes of service and guarantees in-order delivery of frames when the
source and destination are on the same loop.
Link
For Fibre Channel, a connection between two nodes, each having at least one N_Port,
interconnected by a pair of optical or copper links, one inbound and one outbound.
Long Wave
Lasers or LEDs that emit light with wave lengths around 1300 nm. Long-wave lasers are
used for long Fibre Channel links, from 700 to 2000 meters. They are typically used with
single-mode fiber of a 9-micron core size.
Loop Address
The unique ID of a node in Fibre Channel loop topology, sometimes referred to as a loop
ID.
118
Glossary
Download from Www.Somanuals.com. All Manuals Search And Download.
N_Port
A “Node” port. A Fiber Channel-defined hardware entity that performs data
communication over the FC-AL link. It is identifiable by a unique World Wide Name. It
can act as an originator or a responder.
N_Port Identifier
A unique address identifier by which an N_Port is uniquely known. It consists of a
Domain (most significant byte), an Area, and a Port, each 1-byte long. The N_Port
identifier is used in the Source Identifier (S_ID) and Destination Identifier (D_ID) fields
of an FC-AL frame.
Parent Hub
The HP SureStore E short-wave and long-wave hubs support a cascaded topology. In a
cascaded hub topology, the parent hub is the hub that is connected to the LAN
(ethernet). HP SureStore E hubs are configured as a parent or child hub through their
RS-232 interface.
Short Wave
Lasers or LEDs that emit light with wave lengths around 780 nm or 850 nm. Short-wave
lasers are used for FC-AL links up to approximately 700 meters. They are typically used
with multimode fiber. The preferred fiber core size is 50 micron because this fiber has
large bandwidth so that the distance is limited by the fiber attenuation. A 62.5-micron
core size is also supported for compatibility with existing FDDI installations. Fiber of
this type has smaller bandwidth and, in this case, the distance is limited by the fiber
bandwidth.
Topology
The physical or logical layout of nodes on a network. FC-AL topologies include point-to-
point, FC-AL, and fabric. The hub supports FC-AL topology.
Glossary
119
Download from Www.Somanuals.com. All Manuals Search And Download.
120
Glossary
Download from Www.Somanuals.com. All Manuals Search And Download.
INDEX
Numerics
0200
supported for short-wave hub 103
treatment of 38, 87
self-test value 64
10Base-T LED
normal state 71
10Base-T port
long-wave hub 15
short-wave hub 14
troubleshooting 76
cabling
example of nonsupported 37
examples of correct 32, 33
examples of incorrect 35
troubleshooting 68
cabling map 38
A
See also device map
address
See also IP addresses
cascaded hubs 13
configuring 60
MAC 27, 65
cascaded long-wave hubs
configuring 60
reviewing for duplicates 32
troubleshooting 68, 75
address map. See device map
altitude 107
example of correct cabling 34
example of nonsupported 37
examples of incorrect cabling 36
firmware requirements 20
supported topology 19
cascaded short-wave hubs
configuring 60
example of correct cabling 33
example of nonsupported 37
examples of incorrect cabling 36
firmware requirements 18
supported topology 18
Cautions
B
bend radius of fiber cable 87
Boot menu
displaying 50
bypass control 13
bypass persistence setting 56
C
cables
See also serial cable
bend radius 87
connectors 100
maximum supported distances 104
options 95, 98
recommended 100
requirements 100
supported for long-wave hub 103
bending fiber cables 38
cascaded long-wave hubs 19
cleaning connectors 87
device agent code update 53, 82
firmware update sequence 50, 52
incorrect device connections 32
power failure during firmware update 49
saving changes 58
121
Download from Www.Somanuals.com. All Manuals Search And Download.
trap IP address deletion 59
chassis, opening
warning 64, 86
troubleshooting 68, 75
verifying connection 40
diagnostic tests
child hub
running 64
See also hub
distances
configuring 60
increasing 13
definition 60, 117
configuration
loop cabling 32
configurations
maximum supported 104
maximum supported for cascaded long-
wave hubs 19
maximum supported for cascaded short-
wave hubs 18
options 95
standard 92
maximum supported for single short-wave
hub 17
drivers
connections, port
completing installation of 38
verifying 40
requirements 100
connections, RS-232
terminal emulator settings 46
terminal settings 47
connectors
troubleshooting 75
dumb terminal. See terminal
dynamic recognition of nodes 13
E
caution 87
EIA height 27
exchange part number
long-wave hub 98
short-wave hub 98
cleaning 87
troubleshooting 76
controller
updating firmware 50, 82
F
D
failed nodes 13
fan module
data rate requirements 100
default values
description 16
part number 98
removing 89
resetting 59
SNMP names 59
depth 108
replacing 88
fans
device agent code
caution 50, 52
troubleshooting 73, 74
fault LED
updating 52, 81
device map
diagnostics for 64
during self-test 25, 31
long-wave hub 15
short-wave hub 14
troubleshooting 68, 70, 73, 74, 75
features 13
troubleshooting 77
devices
addressing 32, 38
connecting to the hub 38
hardware/software requirements 100
preparing for installation 32
supported wave type 100
physical characteristics 108
122
Index
Download from Www.Somanuals.com. All Manuals Search And Download.
fiber cables
bend radius 87
get community name
default value 58
recommended for long-wave hub 103
recommended for short-wave hub 103
treatment of 38, 87
troubleshooting 76
Fibre Channel connector
caution 87
glass fractures 87
H
hardware
requirements 100
supported 103
heat dissipation 107
cleaning 87
height 108
long-wave hub 15
Hewlett-Packard software depot 49
HP A3724A (model S10 short-wave) 92
HP A3724AZ (model S10 short-wave) 92
HP A4839A (model L10 long-wave) 92
HP A4839AZ (model L10 long-wave) 92
hub
short-wave hub 14
Fibre Channel Manager
configuring cascaded hubs 60
enabling at hub 57–63
firmware requirements 48
firmware requirements for cascaded
hubs 18, 20
overview 12
port bypass 76
Fibre Channel ports
long-wave hub 15
See also long-wave hub
See also short-wave hub
connecting devices 38
connecting to the server 38
EIA height 27
enabling management 57–63
example of nonsupported cabling 37
examples of correct cabling 32
examples of incorrect cabling 35
features 13
short-wave hub 14
firmware
caution 50, 52
device agent code 81
hub controller 82
identification information 65
installation 21–40
incompatible 79
obtaining 49
installing standalone model 24
long-wave exchange part number 98
maximum supported distances 104
menus 43–65
recovery 80
requirements for cascaded hubs 18, 20
troubleshooting 79
updating 48–56
models 92
mounting in rack 27
options 95
updating device agent code 52
updating hub controller 50
front panel
overview 12
long-wave hub 15
rear panel 16
recommended cables 100
resetting 14, 15
positioning in rack 27
short-wave hub 14
G
short-wave exchange part number 98
supported hardware 103
unpacking 24
gateway address
setting 57
Index
123
Download from Www.Somanuals.com. All Manuals Search And Download.
verifying operation 25
Hub Information menu
displaying 65
example of nonsupported cabling 37
exchange part number 98
features 13
humidity 107
maximum supported distances 105
models 92
I
product numbers 92
installation 21–40
recommended cables 101
supported hardware 103
supported topology 19
connecting devices 38
overview 22
preparing devices 32
preparing for 23
loop
duplicate addresses 32, 38
loop configuration 32, 33
long-wave hub 34
rackmounting the hub 27
unpacking the hub 24
verifying connections 40
verifying hub operation 25
intermittent signals 87
internet address
loop ID 32, 38
troubleshooting 68, 75
loop map. See device map
loopback cable
Hewlett-Packard software depot 12, 49
ioscan
troubleshooting 68, 75
verifying connections 40
IP addresses
long-wave part number 98
short-wave part number 98
troubleshooting 69, 76
M
caution 59
MAC address
setting for default gateway 57
setting for hub 57
setting for subnetworking mask 57
setting for trap server 60
determining from front panel 27
determining from RS-232 interface 65
main menu
displaying 43
not displayed 79
L
options 43
LEDs
maintenance 85–90
Management Options menu
displaying 60
10Base-T status 14, 15
fault 14, 15
long-wave hub 15
port 14, 15
power 14, 15
management tool. See Fibre Channel Manager
Manufacturing Settings menu
displaying 54
short-wave hub 14
troubleshooting 70
light signal 87
map, device
troubleshooting 77
masks
long-wave hub
subnet 57
See also hub
master hub
example of correct cabling 33
example of incorrect cabling 36
enabling 54, 61, 62
media access control address. See MAC address
124
Index
Download from Www.Somanuals.com. All Manuals Search And Download.
menus
Boot 50
plenum shroud
installing in rackmount hub 29
part number 98
plug-and-play capabilities 13
port covers 87
Hub Information 65
Management Options 60
Manufacturing Settings 54
Network Setup 58
port LED
Proxy Master 54, 61, 62
Set sysDescr String 54
Set System OID 55
troubleshooting 69, 70, 75, 77
ports
bypass persistence setting 56
bypassed by Fibre Channel Manager 76
long-wave hub 15
short-wave hub 14
treatment of 87
tips for using 44
troubleshooting 79
MIB-2 system name
value 59
models 92
mounting ear brackets, part number 98
power connector
long-wave hub 15
short-wave hub 14
power cord
N
Network Setup menu
displaying 58
troubleshooting 72
power failure
nodes
caution 49
dynamic recognition of 13
nylon retainers, part number 98
power LED
during self-test 25, 31
long-wave hub 15
short-wave hub 14
troubleshooting 70, 72
power line 25, 107
product numbers 92
prompt
O
OmniBook. See PC
operating system requirements 100
overview
Fibre Channel Manager 12
hub 12
not displayed 79
Proxy Master menu
displaying 54, 61, 62
P
parent hub
See also hub
configuring 60
definition 60, 119
part numbers 97
parts
replacement 97
PC
setting up a connection to 45
pinging the hub
installation 26
troubleshooting 78
R
rackmount kit 92, 98
assembly 27
rackmounting the hub 27
rail
installing in rack 28
part number 98
rail nuts, part number 98
rail screws, part number 98
rear panel 16
Index
125
Download from Www.Somanuals.com. All Manuals Search And Download.
receive port, treatment of 87
reference documents 109
removing the fan module 89
replacement parts 97
replacing the fan module 88
warning 88
default value 59
Set sysDescr String menu
displaying 54
Set System OID menu
displaying 55
short-wave hub
requirements
See also hub
cable 100
devices connected to the hub 100
hardware 100
example of correct cabling 32
example of nonsupported cabling 37
examples of incorrect cabling 35
exchange part number 98
features 13
software 100
systems connected to the hub 100
Reset button
maximum supported distances 104
models 92
long-wave hub 15
short-wave hub 14
resetting the hub 14, 15
RS-232 port
product numbers 92
recommended cables 100
supported hardware 103
supported topologies 17
signals, intermittent 87
SNMP trap community name
default value 59
functions of 41–65
long-wave hub 15
setting up a connection 45
short-wave hub 14
troubleshooting 79
SNMP values
resetting default values 59
verifying and setting 58
software depot
S
screws, part number 98
self-test
hub firmware 49
fault LED 25, 31
initializing 25
power LED 25, 31
running 64
troubleshooting 70, 73
values 64
internet address 12, 49
software requirements 100
specifications
environmental 107
physical 108
speed
serial cable
verifying compatibility 32
standalone hub
installing 24
standard configurations 92
status messages
for dumb terminal connection 46
for PC connection 45
serial interface
troubleshooting 79
serial number
loop 79
viewing 65
server
subnetworking mask
setting 57
connecting to the hub 38
set community name
supported hardware 103
126
Index
Download from Www.Somanuals.com. All Manuals Search And Download.
T
temperature 107
terminal
setting up a connection to 46
terminal emulator
software required 45
topologies
long-wave hub 19
short-wave hub 17
supported 17
topology 100
transmit port, treatment of 87
trap community name
default value 59
trap server IP address
caution 59
setting 59
troubleshooting 67–83
LED indicators 70
procedures 68
U
URL
Hewlett-Packard software depot 12, 49
V
voltage
operating 25
requirements 107
troubleshooting 72
W
Warnings
chassis 64, 86
OLM model 114
replacing the fan module 88
uninsulated parts 64, 86
wavelength
requirements 100
verifying compatibility 32
weight 108
width 108
Index
127
Download from Www.Somanuals.com. All Manuals Search And Download.
128
Index
Download from Www.Somanuals.com. All Manuals Search And Download.
Reader Comment Sheet
Hewlett-Packard SureStore E Hub Models S10 and L10
Service and User Manual
We welcome your evaluation of this manual. Your comments and suggestions will help us improve our publications.
Remove this page and mail or FAX it to 916-785-2299. Use and attach additional pages if necessary.
Agree
Disagree
N/A
The manual is well organized.
The information is technically accurate.
Information is easy to find.
Step-by-step procedures are easy to perform.
There are enough examples and pictures.
The examples and pictures are useful.
Comments_________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
Name:
Title:
Phone:
fax:
Company:
Address:
City & State:
E-mail:
ZIP:
Country:
___ Check here if you would like a reply.
Hewlett-Packard has the right to use submitted suggestions without obligation, with all such ideas becoming the property of Hewlett-Packard.
ESSD Roseville Information Engineering A3724-96009 E0899
Download from Www.Somanuals.com. All Manuals Search And Download.
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
C
BUSINESS REPLY MAIL
FIRST CLASS MAIL PERMIT NO. 256
ROSEVILLE, CA
POSTAGE WILL BE PAID BY ADDRESSEE
Attention: Information Engineering (MS5668)
Hewlett-Packard Company
Enterprise Storage Solutions Division
8000 Foothills Boulevard
Roseville, CA 95747-5668
b9574799875b
Fold Here
Tape
Please Do Not Staple
Download from Www.Somanuals.com. All Manuals Search And Download.
Tape
Download from Www.Somanuals.com. All Manuals Search And Download.
Copyright © 1999
Hewlett-Packard Company
Printed in U.S.A.
Manual Part Number
A3724-90006
Manufacturing Part Number
A3724-96009
E0899
*A3724-96009*
Download from Www.Somanuals.com. All Manuals Search And Download.
|