Grizzly Scale T10006 User Manual

MODEL T10006  
50 Kg DIGITAL CRANE SCALE  
OWNER'S MANUAL  
COPYRIGHT © OCTOBER, 2007 BY GRIZZLY INDUSTRIAL, INC.  
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE  
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.  
#JM9992 PRINTED IN CHINA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Instructions for Crane Scales  
8.  
ALWAYS DISCONNECT FROM  
POWER SOURCE BEFORE  
SERVICING. Make sure switch is in  
OFF position, charger is unplugged,  
and battery disconnected before  
servicing.  
1.  
2.  
READ THROUGH THE ENTIRE  
MANUAL BEFORE USING. This  
crane scale presents serious injury  
hazards to untrained users.  
NEVER ALLOW UNQUALIFIED  
PERSONNEL TO SERVICE THIS  
SCALE. Servicing the scale incor-  
rectly may reduce the maximum  
holding capacity of the load cell or  
cause the scale to give incorrect  
readings, which may result in over-  
loading.  
9.  
CHECK FOR DAMAGED PARTS  
BEFORE USING SCALE. Check  
for broken parts, loose bolts,  
cracked or worn components and  
any other conditions that may  
affect machine operation. Repair or  
replace damaged parts.  
3.  
4.  
DO NOT LIFT MORE THAN  
THE MAXIMUM SUGGESTED  
CAPACITY. Be aware that the load  
weight, harnesses and load bear-  
ing equipment all contribute to the  
total load weight. Overloading may  
cause the load to fall.  
10. USE RECOMMENDED ACCES-  
SORIES. Refer to the instruction  
manual for recommended acces-  
sories. The use of improper acces-  
sories may increase risk of injury.  
11. NEVER LET LOADS SWING.  
Unsteady loads may become unbal-  
anced and fall. Swinging motions  
cause wear on components and  
may cause them to break.  
NEVER LIFT HEAVY LOADS  
WHEN TIRED, OR UNDER THE  
INFLUENCE OF DRUGS OR  
ALCOHOL. Be mentally alert at all  
times when lifting or moving heavy  
loads.  
12. USE CORRECT HARNESSES.  
Never use oversized or multiple  
harnesses.  
5.  
6.  
7.  
ONLY ALLOW TRAINED AND  
PROPERLY SUPERVISED PER-  
SONNEL TO OPERATE SCALE.  
Make sure operation instructions  
are safe and clearly understood.  
13. CHARGE ONLY USING THE  
SUPPLIED  
CHARGER  
AND  
BATTERY. Do not use with other  
batteries, chargers or scales.  
NEVER LEAVE A LOAD WHILE  
SUSPENDED. Lower the load to  
the ground and un-hook all loads  
and harnesses before leaving the  
crane scale unattended.  
14. DO NOT EXPOSE BATTERY OR  
CHARGER TO WET OR RAINY  
CONDITIONS. Moisture greatly  
increases the risk of a shock haz-  
ard.  
NEVER SUSPEND THE LOAD  
OVER OR NEAR  
A
PERSON.  
Loads may fall at any given time  
due to overloading, improper load-  
ing procedures, or failure of a com-  
ponent.  
15. DO NOT STORE BATTERY WITH  
CONDUCTIVEMATERIALS.Storing  
the battery in a box of screws or  
nails can cause shorting across the  
battery poles.  
-2-  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2: INTRODUCTION  
Foreword  
Contact Info  
It is our pleasure to provide this manual  
with the Model T10006. It was written to  
encourage safety considerations and guide  
you through general operating procedures  
and maintenance.  
If you have any comments regarding this  
manual, please contact us:  
Grizzly Industrial, Inc.  
C/O Technical Documentation Manager  
P.O. Box 2069  
The specifications, details, and photo-  
graphs in this manual represent the Model  
T10006 as supplied when the manual was  
prepared. However, owing to Grizzly’s pol-  
icy of continuous improvement, changes  
may be made at any time with no obligation  
on the part of Grizzly.  
Bellingham, WA 98227-2069  
Most importantly, we stand behind our  
tools. If you have any service questions or  
parts requests, please call or write us at  
the location listed below.  
Grizzly Industrial, Inc.  
1203 Lycoming Mall Circle  
Muncy, PA 17756  
Machine Data  
Phone: (570) 546-9663  
Fax: (800) 438-5901  
Maximum Capacity............50 Kg (110 lbs.)  
Minimum Load.................0.4 Kg (0.88 lbs.)  
Crane Battery...........Rechargeable 6V/5Ah  
Crane Battery Life..........................50+ hrs.  
Crane Battery Adapter.........DC9V/1500mA  
Operating Temperature.........-10ºC – 40ºC/  
14°F – 104°F  
Operating Humidity..................85% or Less  
Remote Control Battery..............#5, 1.5Vx2  
Digital Display...................5 Digit LCD/LED  
Character Display.....................30mm High  
Scale Body..........Die-Cast Aluminum Case  
Scale Weight ...............................10.35 lbs.  
Read the manual before operation.  
Become familiar with this scale, its  
safety instructions, and its operation  
before beginning any work. Serious  
personal injury may result if safety or  
operational information is not under-  
stood or followed.  
Model T10006 50 Kg Digital Crane Scale  
-3-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 3: SETUP  
Unpacking  
Site Consideration  
Weight Capacity  
Your crane scale was carefully packaged  
for safe shipping. If you discover any dam-  
age after you have signed for delivery,  
immediately call Customer Service at (570)  
546-9663 for advice.  
The Model T10006 crane scale has a  
maximum capacity of 50 Kg (110 lbs.).  
When choosing a mounting site, verify that  
the hardware and the site can withstand  
at least the maximum loading capacity  
as well as any possible overloading that  
may occur.  
Save the containers and all packing materi-  
als for possible inspection by the carrier or  
its agent. Otherwise, filing a freight claim  
can be difficult.  
Working Clearances  
Consider existing and anticipated needs,  
dimensions of your weighing platform, size  
of material to be processed, and whether  
you need the scale to be mobile or in a  
stationary location when establishing an  
installation site for your crane scale. For  
an accurate reading, there must not be any  
items near the scale or weighing platform  
that may lean or fall and add weight.  
When you are completely satisfied with  
the condition of the shipment, you should  
inventory the contents.  
Inventory  
Model T10006 Inventory (Figure 1)  
A. Crane Scale ....................................... 1  
B. Remote Control.................................. 1  
C. Scale Battery Charger ....................... 1  
Power Outlets  
The Model T10006 crane scale includes a  
remote control and scale battery charger.  
When establishing a site for your scale,  
make sure outlets are located near the  
scale so power or extension cords are  
clear of high-traffic areas.  
A
B
C
Do not place crane scale in areas of high  
electrical fields. Electrical fields can pre-  
vent scale accuracy.  
Figure 1. Model T10006 inventory  
No list of safety guidelines is complete, because every work environment is  
different. Always consider safety first and use common sense. Failure to use this  
tool with caution and respect could result in serious personal injury.  
-4-  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Loading Hardware  
When attaching your crane scale:  
1316"  
1. DO NOT use multiple chains or har-  
nesses. Only one point of contact  
should be used on the hook and shack-  
le to lessen the chance of the load fall-  
ing and to allow proper load alignment.  
2 34  
"
2. DO NOT use oversized items or har-  
nesses. Oversized items creates mul-  
tiple points of contact and will not fit  
properly with the crane scale hardware.  
Inaccurate readings, uneven, and dan-  
gerous loads may result.  
3
4"  
Refer to Figures 2 & 3 for Model T10006  
dimensions.  
8 34  
"
Figure 3. Scale side view measurements.  
4"  
Like all tools there is potential danger  
when operating this tool. Accidents  
are frequently caused by lack of  
familiarity or failure to pay attention.  
If normal safety precautions are  
overlooked or ignored, serious  
personal injury may occur.  
 
 
 
 
 
�  
 
To maintain accuracy, the scale  
should remain hanging and not be  
allowed to rest on the ground for a  
significant amount of time.  
Figure 2. Scale front view measurements.  
Model T10006 50 Kg Digital Crane Scale  
-5-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4: OPERATIONS  
Scale Functions  
Hold LED Display  
Load Stable LED Display  
 
 
Tare LED Display  
Zero LED Display  
 
 
 
�  
ON/OFF Button  
Weight in lbs.  
Tare Button  
Remote Receiver Window  
Zero Button  
Figure 4. Scale face.  
Turning the Scale ON  
Tare Function  
After your crane scale has been properly  
mounted, familiarize yourself with the func-  
tions both on the scale and on the remote  
control. Begin by holding down the  
button on the scale to turn it ON (Figure  
4). Each time the scale is turned on, it will  
flash a series of displays. Use the table  
below to familiarize yourself with the dis-  
play and its meanings.  
The tare function will allow you to auto-  
matically deduct the weight of the weigh-  
ing platforms or containers, resulting in a  
final weight of only the items that you want  
weighed (the net weight). When your scale  
is ready, attach your weighing platform to  
the lifting hook at the bottom of the scale,  
then wait until the "STB" light comes on.  
Before placing any items on the platform,  
deduct the weight of the platform by press-  
F
u
n
c
t
i
o
n
Di  
s
p
l
a
y
Action  
ing the  
button on the scale (Figure 4),  
Off/On 8.8.8.8.8 Start up, display twice  
110.25 Maximum capacity, display twice  
U X.XX Current battery voltage  
- - - - - Wait signal  
or by pressing Tare on the remote control.  
After you have selected the Tare function  
for the platform, the scale will return to  
0.00 between loads until you turn off the  
scale.  
0.00 STB light will engage, ready  
To guarantee accuracy for your crane  
scale, allow it warm up without a load for  
3-5 minutes.  
Power Saving  
If the load is left at stable status, ("STB"  
as shown in Figure 4) for longer than 15  
minutes, the screen will flash "–" to save  
power and will return to normal weighing  
readings when the load is changed. If  
the load is left at stable status for over 60  
minutes, the scale will turn OFF automati-  
cally.  
Zero Function  
Generally, your scale will read the weight  
of the hook. To return your scale to zero,  
press the  
4), or on the  
control.  
button on the scale (Figure  
button on the remote  
-6-  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overload Warning  
Remote Control  
Functions  
If the load exceeds the maximum capacity  
(net + tare weight), -OL- will be displayed  
on the screen. DO NOT overload the  
scale. Failure to stay below the maximum  
load rating may result in injury, damage the  
scale, and void your warranty.  
Display LED  
Turning the Scale OFF  
To turn the scale OFF, hold down the  
button on the scale or hold down the OFF  
button on the remote control.  
Zero  
Tare  
 
Note: The scale will not turn off unless it is  
at the main weighing screen.  
MR  
 
M+  
 
 
��  
Clear  
 
 
F1  
Hold  
�  
Do not use this scale during lighting  
and rain storms or other inclement  
weather. Turn the scale off, unplug  
any charging equipment and remove  
the battery.  
 
Off  
�  
If this scale is used for the selling of  
goods, it must be "Legal for Trade"  
and calibrated regularly.  
Figure 5. Remote control buttons.  
Lb/Kg Conversion  
The crane scale can display either in  
pounds or kilograms. To change between  
the measures of weight, press MR button  
on the remote and the screen will display  
SHIFT. Press HOLD and the screen will  
display UN=0 if converting to kilograms,  
or UN=1 if converting to pounds. If the  
current weight is in pounds, the "lb" light  
on the scale will light up. If the current  
weight is in kilograms then the "lb" light  
will be off.  
Model T10006 50 Kg Digital Crane Scale  
-7-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scale Battery  
Advance Tare Weight  
The scale will automatically display the  
current scale battery voltage when you  
turn the scale ON and OFF. To check the  
voltage during use, press the MR button  
on the remote control and the screen will  
display SHIFT. Press the F1 button and the  
screen will display U X.XX. To return to the  
main display, press MR again.  
To input a known tare weight before weigh-  
ing an item, press MR and the screen  
will display SHIFT. Press TARE, and the  
screen will display 000.00. To input the  
desired weight, scroll to the right by press-  
ing the right arrow (TARE) on the remote  
control until you come to the number that  
you would like to change. To increase  
the number from zero, press the left but-  
When the battery voltage is lower than  
U 5.80, the screen will flash to alert you.  
The scale will continue to display for  
approximately one minute longer until -Lb-  
is displayed on the screen, and then turn  
OFF automatically. The scale will need to  
be charged before further use.  
ton (  
) on the remote control. To  
decrease the number, press CLEAR on  
the remote control. When you are satis-  
fied with the current number, press the  
M+ to move to the left. To submit the tare  
amount, press MR and the TARE light will  
come on the scale, automatically deduct-  
ing the imputed tare weight. The tare  
weight will stay the same until the scale is  
turned OFF.  
To recharge the battery:  
1. Turn the scale OFF.  
Clear Function  
2. Connect the supplied adapter into the  
socket located in the back of the scale,  
then into a grounded 110V outlet. The  
light turns orange while charging and  
turns red when charging is complete.  
To clear, press the CLEAR button and  
the screen will flash CLr. If you would  
like to approve the clear command, press  
MR and the screen will display 888.88,  
confirming the deletion. If you would like  
to cancel the clear command, press the  
CLEAR button again. The screen will dis-  
play noCLr canceling the deletion.  
Note: The battery should re-charge for  
at least 8 hours.  
Hold Function  
Search Overload Times  
When the load has been added to the  
scale, wait until the STB light goes off sig-  
nifying that the load is stable (Figure 4). If  
you would like the weight value to remain  
on the screen, press the HOLD button on  
the remote control. To clear the screen,  
press the HOLD button again.  
To review how many instances the scale  
has been overloaded, press the MR button  
and the screen will display SHIFT. Press  
the CLEAR button and the screen will  
display OL=XX, showing how many times  
the scale has exceeded its maximum  
capacity.  
Current Zero Value:  
Display Function  
The current zero value is the tare weight  
that was selected. To view the current  
zero scale value, press the MR button and  
the screen will display SHIFT. Press the  
To change the brightness of the display,  
press F1. Display brightness ranges from 1  
(minimum light) to 5 (maximum light). The  
default display setting is 2.  
button on the remote control to  
display the current zero value.  
-8-  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The remote control is a generic  
remote and may contain buttons that will  
not be used with this particular model.  
Should you lose the included remote con-  
trol, these functions can not be completed.  
To obtain a replacement controller from  
Grizzly; call 1-800-523-4777.  
D
i
s
p
lay  
Action  
- - - - - Wait signal  
Err10 Accumulated weight below capacity  
Err11 Accumulated times exceed (30+)  
Err12 Accumulated weight exced (999.99)  
CLr Delete weight?  
noCLr Cancel deletion  
88888 Confirm deletion  
noACC No accumulated value  
SHIFt Weight conversion  
Reference Guide  
UX.XX Current battery voltage  
SCALE Enter weight adjustment  
SEtUP Enter parameter adjustment  
UAdJ Enter voltage adjustment  
-OL- Overload warning  
For quick references and questions about  
scale displays, use the charts below for  
assistance.  
-Lb- Low battery warning  
End Parameter adjustment ready  
OFF Turn off  
Function  
Button  
D
i
s
p
la  
y
Action  
ON  
8.8.8.8.8  
110.25  
U X.XX  
- - - - -  
0 Scale is ready for use  
OFF  
OFF/  
U X.XX  
OFF  
Scale is OFF  
Zero  
Tare  
Hold  
0.00  
Display reads 0, "Zero" LED is on  
Display reads 0, Tare LED is on  
Weight is held, press HOLD to exit  
TARE/  
HOLD  
0.00  
XXX.XX  
Brightness F1  
1 through 5 1=lowest, 5=highet setting  
Function  
Button Display  
Button  
Action  
Lb/Kg Conversion MR  
SHIFT  
HOLD  
UN=O (weight in Kg, "lb" LED is off)  
UN=1 (weight in lb, "lb" LED is on)  
Battery Voltage  
Current Zero Value MR  
Advance Tare MR  
MR  
SHIFT  
F1  
U X.XX, press MR to exit  
SHIFT  
SHIFT  
/
XXX.XX Current zero value  
TARE to scroll right  
TARE/  
to increase number  
CLEAR to decrease number  
M+ to submit and scroll left  
MR to submit total, "TARE" LED is on  
Overload Review MR  
Clear  
SHIFT  
CLEAR  
OL=XX (Overload= XX times)  
CLEAR CLR  
MR  
CLEAR  
888.88 = confimation of clear  
noCLR = cancel clear  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
-9-  
SECTION 5: MAINTENANCE  
If the scale becomes dirty, clean the  
General  
screen with a soft cloth using a mild win-  
dow cleaner or detergent. Avoid using  
paper towels. DO NOT use solvents,  
Regularly check mounting hardware for  
chemicals or other corrosive materials to  
cracks, unsafe wear, deformation, or  
clean the scale.  
warping. DO NOT attempt to fix these  
items! Discard and replace all damaged  
If the scale will not be used for a prolonged  
hardware. Regularly check for loose pins,  
amount of time, remove the battery. Hang  
rings, screws, and safety latches. Tighten  
the scale at all times and do not allow it to  
or replace any loose items. Damaged or  
rest on the ground.  
loose parts may cause the load to fall and  
may result in serious injury.  
Always keep the scale in a hanging posi-  
tion to relieve strain on the load cell. Never  
leave a load or weighing equipment on the  
scale when not in use. This may cause  
excessive strain on the precision weighing  
device and may result in inaccurate read-  
ings and shorten the life of your scale.  
!
When re-charging the scale battery, charge  
for at least 8 hours. Excessive charging  
will not damage the battery. Batteries must  
be recycled or disposed of properly.  
Always DISCONNECT POWER before  
servicing, adjusting, or doing main-  
tenance to reduce the risk of acci-  
dental injury or electrocution.  
If your scale malfunctions permanently,  
do not attempt to fix it yourself. Contact a  
certified professional for any electrical or  
detailed calibration work.  
BATTERY MUST BE RECYCLED OR DISPOSED  
OF PROPERLY. Consult your local disposal com-  
pany for recycling options in your area.  
-10-  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6: SERVICE  
Troubleshooting  
Symptom  
Possible Cause  
Solution  
No display when  
the scale is turned  
ON.  
1. Battery is dead or damaged.  
1. Check and charge or  
replace battery.  
2. Tighten the battery contact.  
2. Battery contact is loose.  
1. Low battery.  
Display flashes.  
1. Recharge battery.  
Scale will not turn  
ON or OFF.  
1. ON/OFF button is damaged.  
1. Check and clean the button  
and button contact.  
2. Scale is still in function mode. 2. Exit out of the function to  
the main screen, then turn  
OFF the scale.  
Display will not  
show a stable  
weight.  
1. The load is unstable.  
2. Load cell cable is damaged.  
1. Stabilize the load.  
2. Check and replace load  
cell.  
3. The scale has been in a damp 3. Put the scale in a dry envi-  
environment for a prolonged  
amount of time.  
ronment.  
Recharge indicator 1. Damaged adaptor.  
light will not turn  
1. Check or replace the adap-  
tor.  
ON.  
2. The adaptor is not fully  
plugged into the scale or out-  
let.  
2. Insert the plug again.  
Scale unable to  
tare.  
1. Damaged TARE button.  
1. Check and clean the button  
and button contact.  
Large weight error. 1. Scale is not hung properly.  
1. Check the scale, har-  
nesses, etc. Review Setup  
section on Page 4.  
Battery unable to  
charge.  
1. Battery is damaged.  
2. Outlet is damaged.  
1. Replace the battery.  
2. Replace the outlet.  
Remote will not  
work.  
1. Remote control is too far away 1. Move the remote closer to  
from the scale  
the scale.  
2. Dirty receiver window.  
3. Remote control batteries are  
low.  
2. Check and clean window.  
3. Replace controller batter-  
ies.  
The display will not 1. The scale has not had enough 1. Allow the scale to warm up  
show "0" with an  
empty load.  
time to warm up.  
for 3-5 minutes after turning  
it on.  
2. The scale has been placed on 2. Hang the scale.  
the ground and not hung for a  
prolonged time.  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
-11-  
T10006 Parts Breakdown  
 
�  
 
 
 
 
 
�  
�  
�  
 
�  
�  
��  
�  
��  
�  
 
�  
 
 
�  
�  
REF PART #  
DESCRIPTION  
REF PART #  
18 PFH07M  
DESCRIPTION  
FLAT HD SCR M5-.8 X 10  
1
2
3
4
5
6
7
8
9
PT10006001 SCALE BATTERY 6V  
PT10006002 BRACKET  
19 PT10006019 LOAD CELL ASSEMBLY  
20 PT10006020 CIRCUIT BOARD  
PW07M  
PLW09M  
PS79M  
FLAT WASHER 3MM  
LOCK WASHER 3MM  
21 PT10006021 LONG BOW SHACKLE ASSEMBLY  
22 PT10006022 TWO WIRE ASSEMBLY  
PHLP HD SCR M3-.5 X 8  
PT10006006 BACK PANEL  
PT10006007 BACK PANEL WIRE ASSEMBLY  
23 PS111M  
PHLP HD SCR M3-.5 X 4  
24 PT10006024 THREE WIRE ASSEMBLY  
PLW09M  
PS79M  
LOCK WASHER 3MM  
25 PT10006025 GRVD HDLESS CLEVIS PIN 12 X 40  
PHLP HD SCR M3-.5 X 8  
26 PW06M  
27 PR48M  
FLAT WASHER 12MM  
10 PT10006010 SPACER  
EXT RETAINING RING 11MM  
11 PN07M  
12 PS55M  
13 PSB39M  
HEX NUT M3-.5  
28 PT10006028 HOOK ASSEMBLY  
28-1 PT10006028-1 HOOK  
PHLP HD SCR M3-.5 X 10  
CAP SCREW M4-.7 X 20  
28-2 PS98M  
PHLP HD SCR M3-.5 X 16  
14 PT10006014 REMOTE CONTROL  
28-3 PT10006028-3 SAFTEY LATCH  
15 PT10006015 LOAD CELL WIRE ASSEMBLY  
28-4 PLN13M  
LOCK NUT M3-.5  
16 PS79M  
PHLP HD SCR M3-.5 X 8  
32 PT10006032 BATTERY CHARGER  
17 PT10006017 FRONT PANEL  
-12-  
Model T10006 50 Kg Digital Crane Scale  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original  
purchaser from the date of purchase. This warranty does not apply to defects due directly or  
indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of mainte-  
nance. This is Grizzly’s sole written warranty and any and all warranties that may be implied  
by law, including any merchantability or fitness, for any particular purpose, are hereby limited  
to the duration of this written warranty. We do not warrant or represent that the merchandise  
complies with the provisions of any law or acts unless the manufacturer so warrants. In no  
event shall Grizzly’s liability under this warranty exceed the purchase price paid for the prod-  
uct and any legal actions brought against Grizzly shall be tried in the State of Washington,  
County of Whatcom.  
We shall in no event be liable for death, injuries to persons or property or for incidental,  
contingent, special, or consequential damages arising from the use of our products.  
To take advantage of this warranty, contact us by mail or phone and give us all the details.  
We will then issue you a “Return Authorization Number,” which must be clearly posted on  
the outside as well as the inside of the carton. We will not accept any item back without this  
number. Proof of purchase must accompany the merchandise.  
The manufacturers reserve the right to change specifications at any time because they  
constantly strive to achieve better quality equipment. We make every effort to ensure that  
our products meet high quality and durability standards and we hope you never need to use  
this warranty.  
Please feel free to write or call us if you have any questions about the machine or the  
manual.  
Grizzly Industrial, Inc.  
1203 Lycoming Mall Circle  
Muncy, PA 17756  
Phone: (570) 546-9663  
Fax: (800) 438-5901  
E-Mail:  
Thank you again for your business and continued support. We hope to serve you again  
soon!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Greenway Home Products Indoor Fireplace MEF253OK User Manual
Grizzly Lathe G0733 User Manual
HannsG Computer Monitor HQ171DP User Manual
HannsG Computer Monitor HX Series User Manual
Harbor Freight Tools Saw 03733 User Manual
Havis Shields Automobile Accessories C VS 1200 DUR User Manual
Heatcraft Refrigeration Products Fan ELC EFC User Manual
Honeywell Ventilation Hood HR150 User Manual
Hubbell Home Security System CLT1554 User Manual
IBM Laptop Docking Station 92P1836 User Manual